• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Um método automático de extração em fase única para a determinação de cromo em água e vinagre por espectrometria de absorção atômica em forno de grafite

Cunha , Francisco antônio da Silva 27 February 2016 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-05-16T13:29:45Z No. of bitstreams: 1 arquivo total.pdf: 3062751 bytes, checksum: 5355db4f5e8fd0c5ecd86a23e5d0ad77 (MD5) / Made available in DSpace on 2016-05-16T13:29:45Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 3062751 bytes, checksum: 5355db4f5e8fd0c5ecd86a23e5d0ad77 (MD5) Previous issue date: 2016-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The single-phase extraction is based on the formation of a homogeneous mixture formed ideally between two immiscible phases (aqueous and organic) and a third component in the two immiscible phases, is added to achieve opalescence. In this mixture the complexation reactions occur and the subsequent extraction is performed by breaking the phase equilibrium by addition of an excess of the components of the mixture. However, the automation of this method by analyzing flow injection requires a device with a significant degree of complexity and difficult to control operating parameters. The objective of this study was to develop an automatic method of extracting single phase using flow-batch in question applied to the quantification of chromium in water and in commercial samples of vinegar by atomic absorption spectrometry graphite furnace. To this end, modifications have been made both in the mixing chamber (two outputs) as the extraction method, in which more suited to this proposal chemical systems were studied. The performance of the method was attested by statistical tests, in terms of precision (RSD <12%), accuracy (recovery between 82 and 108%), (m0 = 0.32 pg L-1 and LOQ = 0.86 μgL -1) and analytical frequency (26h-1). In this new strategy, the whole process of extraction was performed in mixing chamber quickly, simply and with adequate sensitivity to GF AAS technique. Moreover, it was possible to analyze samples of different matrices using the same method / A extração em fase única baseia-se na formação de uma mistura homogênea entre duas fases idealmente imiscíveis (uma aquosa e uma orgânica) e um terceiro componente miscível em ambas as fases, que é adicionado até atingir a opalescência. Nesta mistura ocorrem as reações de complexação e, a subsequente extração é realizada pela quebra do equilíbrio de fases através da adição de excesso de um dos componentes da mistura. Entretanto, a automação deste método através da análise por injeção em fluxo exige um aparato com significativo grau de complexidade e de difícil controle dos parâmetros operacionais. Assim, o objetivo deste trabalho foi desenvolver uma metodologia automática de extração em fase única utilizando análise em fluxo-batelada aplicada à quantificação de cromo em águas e amostras comerciais de vinagre por espectrometria de absorção atômica em forno de grafite. Para isto, foram feitas modificações tanto na câmara de mistura (duas saídas) como na técnica de extração, na qual foram estudados sistemas químicos mais adequados a esta proposta. O desempenho do método foi atestado através de testes estatísticos, em termos de precisão (RSD < 12%), exatidão (recuperação entre 82 e 108%), (m0 = 0,32 pg L-1 e LOQ = 0,86 μgL-1), e frequência analítica (26 h-1). Nesta nova estratégia, todo o processo de extração foi realizado na câmara de mistura de forma rápida, simples e com sensibilidade adequada para a técnica GF AAS. Além disso, foi possível analisar amostras de diferentes matrizes usando o mesmo método.
2

Pontos quânticos de carbono aplicado à determinação fluorimétrica de cobre(II) em óleos usando um sistema em fluxo-batelada com extração em fase única

Andrade, Stéfani Iury Evangelista de 29 February 2016 (has links)
Submitted by ANA KARLA PEREIRA RODRIGUES (anakarla_@hotmail.com) on 2017-08-01T17:03:36Z No. of bitstreams: 1 arqivototal.pdf: 5257107 bytes, checksum: a3f902aafc4de8ccb68742fb34fb37df (MD5) / Made available in DSpace on 2017-08-01T17:03:36Z (GMT). No. of bitstreams: 1 arqivototal.pdf: 5257107 bytes, checksum: a3f902aafc4de8ccb68742fb34fb37df (MD5) Previous issue date: 2016-02-29 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / In this work, a novel fluorescence method using flow-batch analysis for the determination of copper in edible oil, employing carbon quantum dots (CDs) was developed. The in-line single-phase extraction of iron consisted of the addition of a mixture of isopropyl alcohol/chloroform (70:30, v/v) to dissolve the oil samples. Moreover, an eco-friendly, simple, and low-cost hydrothermal method was developed for preparation of water-soluble fluorescent carbon quantum dots using pineapple juice as carbon precursors. The fluorescence properties of CDs were examined by fluorescent detection of Cu(II) in oil. Their photoluminescence can be significantly quenched by simply using the buffer solution PBS of pH 4.0. This mechanism was presumably explained by the interactions between the surface groups of CDs with metal ions studied. Concerning the flow-batch analysis a new mixing chamber was developed in polytetrafluoroethylene provided with quartz windows in order to allow the excitation and fluorescence detection online. For this, an LED UV was used as the excitation source and a portable spectrofluorometer as detector. The limits of detection and relative standard deviation were estimated as 2.9 μg L−1 and < 2.5 % (n=3). The analysis of interfering was successful for the major ions present in solution, revealing significant percentage interference (≤ 5 %).The precision of the method was evaluated by recovery test (96 to 106 %). The robustness of the method was evaluated by intra- and inter- day comparison of the results obtained and using the reference method with detection by atomic absorption graphite furnace at a 95% level of statistical confidence. Finally, the system showed quite satisfactory analytical frequency (60 h–1) and considerably reducing the consumption of chemicals. Thus, it is demonstrated appreciably the viability of new fluorescent method, thus allowing the development of new analytical strategies employing potentially useful carbon quantum dots and flow-batch analyzer. / Neste trabalho foi desenvolvido um novo método automático em fluxo-batelada baseado em pontos quânticos de carbono (PQCs) para determinação fluorescente de cobre(II) em óleos comestíveis. O método analítico proposto apresenta como estratégia de pré-tratamento da amostra a disponibilização on-line do cobre por meio de extração em fase única utilizando uma mistura de solventes álcool isopropílico/clorofórmio na proporção 70:30 (v/v). Para a preparação dos PQCs, foi empregado o tratamento hidrotérmico, simples e de baixo custo, do suco de abacaxi, como bioprecursor. Foi constatado que a fluorescência dos PQCs pode ser significativamente reduzida na presença do Cu(II) simplesmente utilizando um tampão PBS pH 4,0. O mecanismo de extinção da fluorescência pode ser atribuído as interações entre os grupos presentes na superfície dos PQCs com os íons Cu(II). Concernente ao sistema automático fluxo-batelada uma nova câmara de mistura foi construída em politetrafluoretileno, provida de três janelas de quartzo, com o objetivo de permitir a excitação e aquisição dos espectros de fluorescência on-line. Para isso, foi utilizado um LED-ultravioleta como fonte de excitação e um espectrofluorímetro portátil como detector. Os limites de detecção e os desvios padrão relativo foram estimados como sendo 2,9 μg L–1 e < 2,5 % (n = 3), respectivamente. A análise de íons interferentes foi realizada com êxito para os principais íons metálicos presentes na matriz da amostra, não revelando interferência percentual significativa (≤ 5 %). A exatidão do método foi avaliada através do teste de recuperação (96 a 106 %). A robustez do método foi avaliada por comparação intra e inter-dia dos resultados obtidos e empregando o método de referência com detecção por absorção atômica em forno de grafite, a um nível de 95% de confiança estatística. Por fim, o sistema apresentou frequência analítica bastante satisfatória (60 h–1) com uma redução considerável do consumo de produtos químicos. Desta forma, é evidenciado de modo apreciável a viabilidade do novo método fluorescente, permitindo, dessa maneira, o desenvolvimento de novas estratégias analíticas potencialmente úteis baseadas em nanopartículas de carbono e automação em sistemas fluxo-batelada.

Page generated in 0.0685 seconds