• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 17
  • 14
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efetividade da utilização dos padrõies respiratórios no controle da ansiedade materna durante o primeiro período de trabalho de parto: ensaio clínico contolado e randomizado

FREIRE, Alessandra da Boaviagem 30 June 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-08-09T12:49:12Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) BIBLIOTECA DISSERTAÇÃO VERSÃO PARA BANCA FINAL.pdf: 1603954 bytes, checksum: a9342846df18a37bc890c44c989bd9c1 (MD5) / Made available in DSpace on 2016-08-09T12:49:12Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) BIBLIOTECA DISSERTAÇÃO VERSÃO PARA BANCA FINAL.pdf: 1603954 bytes, checksum: a9342846df18a37bc890c44c989bd9c1 (MD5) Previous issue date: 2015-06-30 / FACEPE / Objetivo: Avaliar a efetividade da utilização de padrões respiratórios no controle da ansiedade materna durante o primeiro período de trabalho de parto. Métodos: Trata-se de um ensaio clínico controlado e randomizado, envolvendo 140 primíparas em trabalho de parto ativo, com idade gestacional entre 37 e 42 semanas e Idade entre 12 e 40 anos. Foram excluídas gestações múltiplas e com feto morto, parturientes em uso de analgesia, que apresentem instabilidade clínica e transtornos psiquiátricos. A ansiedade materna (desfecho primário) foi avaliada através do Inventário de Ansiedade Traço-Estado. A dor, satisfação materna e fadiga (desfechos secundários) foram avaliadas através da escala visual analógica (EVA) e da escala modificada de Borg respectivamente. No grupo intervenção foram realizados os seguintes padrões: respiração lenta e profunda, suspiro com pausa pós-expiratória e retardo expiratório a depender da fase da dilatação e intensidade da contração, enquanto que o grupo controle recebeu os cuidados de rotina do serviço. As mensurações foram feitas durante a admissão, e após 2 horas. Para a comparação das características basais dos dois grupos, foram utilizados para as variáveis categóricas os testes qui-quadrado de associação ou exato de Fisher e para as variáveis contínuas o test “t” de Student ou Mann-Whitney. Para a associação entre a variável independente e dependente foram calculadas as diferenças de média (DM) com os respectivos intervalos de confiança a 95%. Para as variáveis dependentes dicotômicas foi calculado o risco relativo (RR) com intervalos de confiança a 95%. Toda a análise desses dados foi realizada nos softwares Statistical Package for the Social Sciences (SPSS) 20.0 para Windows. Admitiu-se o nível de significância de 5%. Os resultados das associações foram tratados através de uma análise de sensibilidade pelo principio de intenção de tratar em apenas as variáveis respostas que apresentaram valores faltantes. Essa análise estatística de imputação dos dados foi realizada com o software Stata 12.1SE (StataCorp - College Station, Texas 77845 USA). Resultados: Não houve diferença entre os grupos em relação ao grau de ansiedade materna (DM: 0,3; IC95% -4.2 a 4.8 e p: 0.91), dor (DM: 0,0; IC95% -0.8 a 0.7), satisfação (DM:0.9;IC95%: -0.1 a 2.0), fadiga (DM: -0.5;IC95%: -1.4 a 2.5) e a duração do trabalho de parto (DM: 0,28;IC(95% -1,32 a 0,75). Também não houve associação entre o uso dos padrões respiratórios e a via de parto (RR: 0,90;IC95% 0,74 a 1,09) e Apgar de 5 minuto (RR: 1,05; IC95% 0,95 a 1,16). Conclusão: Os resultados mostram que o uso dos padrões respiratórios do tipo respiração lenta e profunda, suspiro pós-expiratório e o retardo expiratório durante o primeiro período do trabalho de parto não se mostraram efetivos no controle da ansiedade, dor, fadiga E SATISFAÇÃO materna. Portanto, a adoção de uma orientação respiratória durante o primeiro período de trabalho de parto deve ser realizada de maneira criteriosa e cautelosa, respeitando-se as preferências da paciente / Objective: The purpose of the study was to evaluate the effectiveness of breathing patterns in controlling maternal anxiety during the first labor period. Methods: This was a randomized controlled trial study, which included 140 primiparous women in active labor, gestational age between 37 and 42 weeks and Age between 12 and 40 years. Multiple pregnancies and dead fetuses were excluded, as well as pregnant women in use of analgesia, who also are clinically unstable and have psychiatric disorders. During admission, a questionnaire was used to identify the sociodemographic and obstetric profile in order to characterize the sample. Maternal anxiety was evaluated with the Trait Anxiety Inventory-State. Pain and maternal satisfaction were evaluated with visual analog scale (VAS) and maternal fatigue was evaluated with modified Borg scale. The groups were randomized into control and intervention (IG = 67; CG = 73). The following breathing standards were used on intervention group: slow, deep breath, sigh with post-expiratory pause and expiratory delay depending on the extension phase and intensity of contraction, while the control group received routine care service. The measurements were made during admission and after 2 hours. Statistical analysis was conducted by comparing the baseline characteristics of the two groups; for categorical variables a chi-square test was used and Fisher exact association, when necessary; for continuous variables, student “t” test was used when these variables were normally distributed, otherwise Mann-Whitney U test was used. For the association between the independent variable and the dependent or predictor variables, mean differences were calculated with their confidence intervals at 95%. For dichotomous dependent variable (mode of delivery, Apgar 5 minutes) relative risk was calculated with confidence intervals at 95%. The Data analysis was performed using Statistical Package for Social Sciences (SPSS) 20.0 software for Windows. The significance level was set of 5%. .Results of the associations were treated through a sensitivity analysis by intention to treat principle with variables that had missing values. Variables of mode of delivery and Apgar 5 minutes were considered the worst case scenario (cesarean delivery and Apgar 5 minutes <7). For the other variables: anxiety, pain, fatigue and satisfaction maternal data were imputed by the MI method (“Multiple imputation”). This statistical analysis imputation of data was performed using Stata software 12.1SE (StataCorp – College Station, Texas 77845 USA). Results: We found a mean difference (MD) between the degree of maternal anxiety of 0.3 (95% CI -4.2 to 4.8 and p: 0.91), pain (MD: 0.0 (95% CI -0.8 to 0.7 and p: 0.94) , satisfaction (MD: 0.9 (95% CI: -0.1 to 2.0 p: 12:07), fatigue (MD: -0.5 (95% CI: -1.4 2.5 p: 0.6) and the labour the first period duration MD: 0.28 (IC (95%) -1.32 to 0.75). With regards to mode of delivery RR:. 0.90 (95% CI 0.74 to 1.09) and the Apgar score of 5 minutes RR: 1.05 (95% CI 0.95 to 1.16). Conclusion: The results show that the use of breathing patterns type slow and deep breathing, post-expiratory breath and the expiratory delay during the first period of labor were not effective in controlling anxiety, pain, satisfaction and maternal fatigue. Therefore, the adoption of a respiratory guidance during the first period of labor should be performed judiciously and cautiously, respecting the preferences of the patient.
12

Estudo dos principais parâmetros da confiabilidade de falha a fadiga de um riser marítimo de produção / Study of main parameters of reliability of faillure due to fatigue of a offshore riser

Stefane, Wânia 16 August 2018 (has links)
Orientador: Celso Kazuyuki Morooka / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica e Instituto de Geociências / Made available in DSpace on 2018-08-16T19:35:21Z (GMT). No. of bitstreams: 1 Stefane_Wania_M.pdf: 1299302 bytes, checksum: 5e10da42a4a2b40651a938ac99f33efb (MD5) Previous issue date: 2010 / Resumo: O presente trabalho propõe um procedimento para calcular a probabilidade de falha por fadiga em um SCR (Steel Catenary Riser), identificando os principais parâmetros e avaliando a influência destes na probabilidade desse tipo de falha. São consideradas nesse procedimento as condições oceanográficas, tais como esforços de ondas, correntezas e movimentos da plataforma, e as incertezas presentes no dano acumulado total à fadiga ¿ dado pela regra de Miner-Palmgren. A metodologia adotada é probabilística e se baseia no Método de Confiabilidade de Primeira Ordem (FORM). Uma função de falha para o SCR é definida considerando-se a resistência e os carregamentos aplicados no riser, a aleatoriedade das condições oceanográficas e as características mecânicas do SCR. Neste trabalho, o procedimento proposto foi implementado em um programa comercial e aplicado para um caso reportado na literatura e para outro caso, considerando dados obtidos via Petrobras, de um campo marítimo brasileiro em operação. Os resultados de probabilidade de falha por fadiga, bem como de vida útil, são discutidos e avaliados para diferentes localizações ao longo do comprimento do SCR. Estes resultados mostraram-se bons quando comparados com os resultados encontrados na literatura. Através destes resultados verificou-se a sensibilidade da probabilidade de falha por fadiga para os principais parâmetros, sendo o parâmetro m da curva S-N o mais influente. / Abstract: The current work presents a procedure to evaluate the probability of fatigue failure for an offshore Steel Catenary Riser (SCR), through identification and assessment of the influence of the main parameters involved in the probability of failure due to fatigue mechanism. Ocean conditions such as waves, currents and platform motions, as well as uncertainties due to total cumulative damage given by Miner-Palmgren¿s rule, are considered in this procedure. A probabilistic methodology is adopted, which is based on the First Order Reliability Method (FORM). A failure function for the SCR is defined considering the structural strength and the loads acting on the riser, as well as the random nature of ocean conditions and mechanical properties of the SCR. The suggested procedure was implemented and applied for two practical cases. The first case uses data from literature and the second one considers data from a typical Brazilian offshore operation field by Petrobras. In the calculations, results for the probability of failure are, as well as the riser service life, discussed and assessed at different locations along the SCR length. Good results were obtained from the analysis as they are comparable and very close to the results observed in literature. From those results, the sensitivity of the probability of failure due to fatigue for a SCR could be verified. It could also be observed that the m parameter from SN curve has shown to be the most effective parameter. / Mestrado / Explotação / Mestre em Ciências e Engenharia de Petróleo
13

Respostas neuromusculares, metabolicas e percepção de esforço durante exercicios intermitentes de alta intensidade / Metabolic and neuromuscular responses and rate of perceived exertion during high-intensity intermittent exercise

Okano, Alexandre Hideki 29 February 2008 (has links)
Orientador: Antonio Carlos de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-11T02:55:02Z (GMT). No. of bitstreams: 1 Okano_AlexandreHideki_D.pdf: 920056 bytes, checksum: e16cc719a684f3e7e9a4132585472631 (MD5) Previous issue date: 2008 / Resumo: O propósito do presente estudo foi verificar o efeito de diferentes tempos de esforço:pausa (E:P) no exercício intermitente de alta intensidade sobre as respostas neuromusculares, o lactato sangüíneo (LACS) e a percepção subjetiva de esforço (PSE). Doze ciclistas, do sexo masculino, foram submetidos a três protocolos de esforços intermitentes de alta intensidade. Os protocolos de exercício intermitente longo (EIL = 4 x 30 s, com intervalo de dois minutos entre cada teste), exercício intermitente médio (EIM = 8 x 15 s, com um minuto de intervalo) e exercício intermitente curto (EIC = 16 x 7,5 s, com intervalo de 30 s entre os testes) foram realizados aleatoriamente, com intervalo de 48 horas entre cada protocolo. Os índices de decréscimo da potência de pico e do trabalho foram mais elevados (P<0,05) nos protocolos de EIL (12 e 15%) e EIM (11 e 13%) quando comparado ao EIC (4 e 7%), respectivamente. O trabalho total realizado nos protocolos EIM (70143 J) e EIC (67071) foram superiores (P<0,05) em relação ao EIL (62011). Houve redução (P<0,05) da amplitude dos sinais eletromiográficos (EMG-RMS) com o decorrer dos esforços nos protocolos de EIL e EIM, porém, sem alterações no EIC. Com relação à freqüência mediana, houve redução somente no protocolo de EIL. O LACS e a PSE foram superiores nos EIL e EIM quando comparados ao protocolo de EIC. De acordo com os resultados podemos concluir que os protocolos EIL e EIM acarretam em maiores níveis de fadiga neuromuscular, LACS e PSE / Abstract:The purpose of this study was to evaluate the effects of different work: rest time relation during high-intensity intermittent exercise on the neuromuscular responses, blood lactate levels (LAC) and rate of perceived exertion (RPE). Twelve male cyclists performed three protocols of high intensity intermittent exercise. The protocols of long intermittent exercise tests (IEL = 4 x 30 s, with two minutes rest between each test), medium intermittent exercise (IEM = 8 x 15 s, with one minute rest between the tests) and short intermittent exercise (IES = 16 x 7,5 s, with 30 s rest between tests) were conducted randomly, separated by 48 hours. The rates of decline in peak power and total work were higher (P<0,05) on the protocols IEL (12 and 15%) and IEM (11 and 13%) when compare to IES (4 and 7%), respectively. The total work done during protocols IEM (70143 J) and IES (67071 J) were higher (P<0,05) when compare to IEL (62011J). There was a reduction (P<0,05) in electromyography activity (root-mean-square RMS) during the protocols of IEL and IEM, however, no significant changes in IES were found. Considering the median frequency from the electromyography signals, there was only significant reduction in IEL. The LAC and RPE were higher in IEL and IEM when compared to IES. According to the results is possible to conclude that the IEL and IEM protocols cause higher neuromuscular fatigue, LAC and RPE / Doutorado / Ciencia do Desporto / Doutor em Educação Física
14

Fadiga multiaxial aplicada à avaliação da vida de virabrequins / Multiaxial fatigue applied to evaluation of crankshafts's life

Minucci, Frederico Rodrigues 07 December 2010 (has links)
Orientador: Auteliano Antunes dos Santos Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-16T12:18:17Z (GMT). No. of bitstreams: 1 Minucci_FredericoRodrigues_M.pdf: 2447535 bytes, checksum: 1f8099b913d0c77861627fd93867cfb4 (MD5) Previous issue date: 2010 / Resumo: O virabrequim é um dos principais componentes do motor de combustão interna e sua função é, em conjunto com a biela, transformar o movimento de translação do pistão em movimento de rotação. Como sofrem carregamentos cíclicos durante toda sua vida útil, o principal tipo de falha de um virabrequim é por fadiga. Porém, por estarem sujeitos a carregamentos complexos, tensões multiaxiais são geradas resultando no problema da fadiga multiaxial. Nos últimos anos, diversos métodos que tratam desse problema foram apresentados, porém, até hoje, nenhuma abordagem foi universalmente aceita. Este trabalho apresenta a avaliação da vida de dois virabrequins fornecidos pela empresa Thyssen Krupp Metalúrgica Campo Limpo Ltda quanto à falha por fadiga utilizando os critérios de fadiga multiaxial para elevado número de ciclos de Matake, McDiarmid e DangVan, baseados nos planos críticos, e os critérios de Sines, Crossland e Kakuno-kawada, baseados nos invariantes de tensão. Ao longo do trabalho, é descrita a cinemática e a dinâmica do movimento de um virabrequim bem como uma forma adequada de tratamento para a vibração torcional. Com base nos esforços, é feita a análise de tensões através do método de superposição de esforços unitários. Os resultados das tensões são utilizados como entradas em um algoritmo especialmente desenvolvido para os critérios de fadiga citados. As análises feitas mostram que os projetos analisados são seguros quando avaliados utilizando tais critérios / Abstract : The crankshaft is one of the most important components of the internal combustion engine and its function is, with the rods, transforming the linear movement of the piston into rotation. As it is under cyclic loading during all of his life, the main type of failure in these components is due to fatigue. However, as they are subject to complex loads, multiaxial stresses arise, which results in the problem of multiaxial fatigue. Recently, several approaches to this problem were proposed but until now, there is no universally accepted approach. This work evaluates the life of two designs of crankshafts provided by Thyssen Krupp Metalúrgica Campo Limpo Ltda with respect to the fatigue failure using the multiaxial high-cycle fatigue criteria of Matake, McDiarmid and Dang Van, based on critical planes, and Sines, Crossland and Kakuno-Kawada, which are based on the stress invariants. Throughout the work it is described the kinematics and the dynamics of the cranckshaft movement and an appropriate form of treatment for the torsional vibration. Based on the loads, a stress analysis is performed using the finite elements method and the superposition principle. The resulting stresses are used as inputs in a specially developed algorithm to evaluate the fatigue criteria cited. These analyses show that the designs are safe when they are evaluated using such criteria / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
15

Estudo da síndrome de fragilidade em idosos residentes na comunidade e sua associação com parâmetros hematológicos / Study on the frailty syndrome in community-dwelling elderly and its association with anemia and hematological parameters

Moraes, Zélia Vieira de 18 August 2018 (has links)
Orientador: André Fattori / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-18T02:10:48Z (GMT). No. of bitstreams: 1 Moraes_ZeliaVieirade_M.pdf: 2183425 bytes, checksum: 4404a3b0fb6ea373f7f9f5b2941e39b3 (MD5) Previous issue date: 2011 / Resumo: Objetivos: Investigar relações entre indicadores de fragilidade, anemia e parâmetros hematimétricos (HGB, HTC, VCM, RDW, RETabs) em idosos de 65 anos e mais, recrutados na comunidade, segmentados por gênero e idade. Métodos: Os idosos foram recrutados em domicilio, em 35 setores censitários urbanos de Campinas selecionados por critério de conveniência dentre os 88 que integraram a amostra casualizada de um estudo populacional sobre fragilidade Em sessão única realizada em local publico, realizada coleta de sangue (hemograma e reticulocitos) e levantados dados sócio-demográficos, antropométricos, de saúde entre eles medidas de fragilidade, de acordo com os critérios definidos por Fried e col.(2001). Resultados: Participaram 255 idosos (68% mulheres), idade media = 73,12 anos (±5,98), escolaridade media = 4,39 anos ±4,21 anos; 25% analfabetos), e renda familiar media = 2,23 salários mínimos mensais ±2,74. A prevalência de fragilidade foi de 7,06% e de anemia, 9,8%. As mulheres frágeis apresentaram valores menores de HGB (p: 0,017/12,46 ±1,09) e maiores de RDW (p: 0,24/14,24 ± 1,43); menores valores de HGB associaram-se significativamente com baixa forca preensão e lentidão da marcha. Na amostra total, anemia (HGB <12g/dL para mulheres e < 13 g/dL para homens) associou-se com fragilidade e com perda de peso não intencional; RETabs e HGB associaram-se com idade; os valores de HGB e RETabs correlacionaram-se positiva e significativamente. Conclusões: Embora tenham sido atingidos valores no limite inferior da normalidade, em nenhum deles a média de HGB foi inferior a 12g/dL. As alterações hematimétricas estiveram mais correlacionadas com fragilidade entre as mulheres que entre os homens. Os dados sugerem a oportunidade de se buscar ativamente critérios diagnósticos mais exigentes para anemia e de empreender o rastreio sistemático dessa condição e de seus precursores na população idosa / Abstract: Objectives: To investigate relationships between indicators of fragility, anemia, and hematological parameters (HGB, HTC, MCV, RDW, RetAbs) in the elderly age 65 and over, recruited from the community, segmented by gender and age. Methods: Subjects were recruited at home, in 35 urban census tracts of Campinas selected by criteria of convenience among the 88 that made up the random sample of a population study on frailty in a single session held in a public place, was collected blood sample (blood count and reticulocytes) and collected sociodemographic, anthropometric, health, including measures of fragility, according to the criteria defined by Fried et al. (2001). Results: Participants were 255 elderly (68% women), mean age = 73.12 years ( ± .5,98), educational mean = 4.39 years ± 4.21 years, 25% illiterate), and median family income = 2 , 23 ± 2.74 times the minimum wage. The prevalence of frailty was 7.06% and anemia, 9.8%. Women showed lower values of fragile HGB (p: 0.017 / 12.46 ± 1.09) and higher RDW (p: 0.24 / 14.24 ± 1.43), lower values of HGB were significantly associated with low grip strength and slowness of gait. In the total sample, anemia (HGB <12 g / dL for women and <13 g / dL for men) was associated with frailty and with weight loss; RetAbs and HGB were associated with age, the values of HGB and RetAbs correlated positively and significantly. Conclusions: Although values have been reached at the lower limit of normal, none of them the average of HGB was less than 12 g / dL. Hematological alterations most closely correlated with weakness among women than among men. The data suggest the opportunity to actively seek more stringent diagnostic criteria for anemia and to undertake systematic screening of this condition and its precursors in the elderly / Mestrado / Mestre em Gerontologia
16

Estudo dos principais parâmetros da confiabilidade de falha por fadiga de riser marítimo de perfuração / Study of the main parameters of the fatigue reliability failure in marine drilling riser

Chagas, Bruno Luiz Barbosa das, 1986- 30 August 2018 (has links)
Orientador: Celso Kazuyuki Morooka / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica e Instituto de Geociências / Made available in DSpace on 2018-08-30T02:08:44Z (GMT). No. of bitstreams: 1 Chagas_BrunoLuizBarbosadas_M.pdf: 3797109 bytes, checksum: 1ef50f3d002aa234dbe301fd26044c8f (MD5) Previous issue date: 2015 / Resumo: O presente trabalho tem como objetivo principal avaliar a probabilidade de falha por fadiga em um riser de perfuração. Os parâmetros mais importantes são identificados e sua influência na probabilidade de falha é analisada. De acordo com as premissas do comportamento dinâmico de um riser, a partir do qual se obtém o dano total à fadiga, juntamente com a teoria da confiabilidade e as variáveis de incerteza, aplicou-se o método FORM (First Order Reliability Method) determinando-se a probabilidade de falha por fadiga em um riser. O procedimento foi adotado para um campo marítimo em operação, a fim de se demonstrar a sensibilidade das variáveis envolvidas na função de estado limite. Neste estudo consideraram-se o expoente m da curva S-N e a constante K da curva S-N como sendo ora determinísticos ora probabilísticos. Assim sendo, a partir das premissas e procedimentos acima elencados, os resultados de probabilidade de falha para análise probabilística se mostraram mais sensíveis que a análise determinística nas quatro diferentes localizações críticas ao longo do comprimento do riser de perfuração / Abstract: The primary objective of this work is to evaluate the probability of fatigue failure in a drilling riser. Key parameters are identified and their influence on the probability of failure is analized. Based on riser dynamic behavior, which givestotal fatigue damage, along with the reliability theory and the variables of uncertainty, the method FORM (First Order Reliability Method) was applied to determine the probability of fatigue failure on a riser . The procedure was applied in a offshore field in operation in order to demonstrate the sensitivity of the variables involved in the limit state function.In this study the exponent m of the SN curve and the constant K of SN curve were considered to be either deterministic or probabilistic. Thus, according to adopted assumptions and procedures, the results of probability of failure for probabilistic analysis have shown to be more sensitive than deterministic analysis in the four different critical locations along the length of the drilling riser / Mestrado / Explotação / Mestre em Ciências e Engenharia de Petróleo
17

Uma metodologia para a avaliação dos gradientes de tenacidade a fratura ao longo da camada cementada do aço SAE 5115 / A model for fracture toughness evaluation of the carburized layer for SAE 5115 steel

Sandor, Leonardo Taborda 28 March 2005 (has links)
Orientador: Itamar Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T09:29:09Z (GMT). No. of bitstreams: 1 Sandor_LeonardoTaborda_M.pdf: 9634671 bytes, checksum: 3b7603db85e265d8bd0e3fc244928942 (MD5) Previous issue date: 2005 / Resumo: Este trabalho propõe um modelo para avaliar pontualmente as variações de tenacidade à fratura ao longo da camada cementada de um aço SAE 5115. A pequena espessura dessas camadas impede a retirada de corpos de prova nas dimensões especificadas pelas normas de ensaios de tenacidade à fratura. Assim, para simular uma camada cementada retirou-se corpos de prova de tração e de tenacidade à fratura de amostras de aços SAE 5115, 5140, 5160 e 52100 assumindo a influência local apenas da variação do teor de carbono e considerando que os teores dos demais elementos de liga são essencialmente constantes. Os corpos de prova após eletrodeposição de cobre foram tratados termicamente numa carga industrial de cementação, têmpera e revenimento para serem submetidos aos efeitos térmicos sem absorção de carbono. Os resultados da análise microestrutural, dos ensaios de microdureza, de tração e de tenacidade à fratura foram agrupados em um único gráfico e comparados com o perfil de cementação de peças de aço SAE 5115 tratadas nas mesmas condições. Foi confirmado que a tenacidade à fratura varia inversamente proporcional à microdureza (HV1) e que a previsão do comportamento de uma trinca numa camada cementada pode ser feita por meio de equação ou diagrama que relacionam a miicrodureza HV1 com a tenacidade à fratura (K1c ou CTODc) / Abstract: The purpose of this work is to propose a model for evaluating the fracture toughness along the SAE 5115 steel carburized layer. Due to the small thickness of those layers, it is impossible to machine specimens from those layer in accordance with standards. For simulating the microstructures of the carburized layer in order to get samples for tensile and the fracture toughness testing, specimens of SAE 5115, 5140, 5160, and 52100 steels assuming the local influence just of the variation of the content of carbon and considering that the contents of the other alloy elements are essentially constant. The specimens after electroplated copper layer were heat treated in an industrialload of carburizing, quenching, and tempering for they be submitted to the thermal effects without absorption of carbono The results of the microstructure analysis and microhardness, tension, and fracture toughness tests were placed in a single graph and compared with the profile of the carburizing of the steel SAE 5115 heat treated in the same conditions. It was confirmed that the fracture toughness varies inversely proportional to the microhardness (HV1) and that the forecast of the behavior of a crack in a carburized layer can be made through equation or it designs that relate the microhardness (HV1) with the fracture toughness (KIC or CTODc) / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica

Page generated in 0.071 seconds