• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 7
  • 3
  • 1
  • Tagged with
  • 127
  • 91
  • 51
  • 43
  • 41
  • 40
  • 40
  • 38
  • 36
  • 35
  • 32
  • 27
  • 27
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Impunidad de las faltas penales y su repercusión en la seguridad ciudadana en el Perú

Monroy Meza, Juan Carlos January 2018 (has links)
El documento digital no refiere un asesor / Publicación a texto completo no autorizada por el autor / Se sumerge en el tratamiento normativo de las faltas penales en el Perú, a efectos de identificar las causas y establecer las consecuencias de la ineficacia de dichas disposiciones, proponiendo reformas legislativas que hagan efectivo dicho tratamiento y se cumpla su finalidad como mecanismo de control social, toda vez que su ineficacia se evidencia ante el crecimiento desbordante de la criminalidad en el País, para lo cual se recoge información teórica y de campo, siguiendo los pasos de una investigación no experimental de tipo causal explicativo, que subsume los tipos exploratorio y descriptivo, con un universo que incluye datos a nivel nacional y resultados de otras investigaciones afines. / Tesis
12

Las faltas administrativas y su relación con los delitos contra la administración pública

Mendivil Mamani, Angel Ernesto 14 February 2018 (has links)
La potestad sancionadora de la Administración Pública tiene que realizarse con respeto al debido procedimiento administrativo, establecido por el Tribunal Constitucional, uno de estos principios es el ne bis in ídem, que establece que nadie puede ser sancionado o procesado dos veces por los mismos hechos. Una de las entidades que imparte el procedimiento administrativo sancionador es la Contraloría General de la República a partir de la Ley N° 29622 y su Reglamento se ampliaron las facultades sancionadoras de la Contraloría General de la República, con el propósito de sancionar administrativamente a funcionarios que habrían incurrido en faltas administrativas en el desempeño de sus funciones, sin embargo si bien esta decisión la encuentra acertada como política anticorrupción vemos que muchos de los fundamentos de estas faltas administrativas que son consideradas como muy graves compartirían el mismo fundamento que algunos tipos penales vigentes en nuestro Código Penal. En ese sentido, me planteo como objetivo dilucidar si no sería el fundamento jurídico de algunas faltas administrativas y de algunos delitos el mismo, para lograr el mismo divido el presente trabajo en tres partes, siendo la primera de ellas el estudio de la función punitiva del Estado y el desarrollo de los principios constitucionales de la responsabilidad disciplinaria de los servidores públicos y de la potestad sancionadora de la Contraloría General de la República. En la segunda parte del presente trabajo se tratara un aproximamiento a los principales delitos contra la administración pública, como el Cohecho, Peculado, Negociación Incompatible, Colusión, Tráfico de Influencias, Nombramiento o Aceptación Indebida para Cargo Público, Omisión, rehusamiento o demora de actos funcionales, Concusión y Malversación de fondos. En la tercera parte se realizara un análisis comparativo entre las faltas administrativas sancionadas por la Contraloría General de la República y algunos delitos contra la administración pública a partir de la Ley N° 29622, para luego pasar a las conclusiones y recomendaciones. / Trabajo académico
13

Proposição de um método de detecção de FAI baseado nos componentes harmônicos de baixa frequência.

LIMA, Érica Mangueira. 03 May 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-05-03T20:55:24Z No. of bitstreams: 1 ÉRICA MANGUEIRA LIMA – DISSERTAÇÃO (PPGEE) 2016.pdf: 3788955 bytes, checksum: b005e5fd7bcddd43613e8d3de47b9e6c (MD5) / Made available in DSpace on 2018-05-03T20:55:25Z (GMT). No. of bitstreams: 1 ÉRICA MANGUEIRA LIMA – DISSERTAÇÃO (PPGEE) 2016.pdf: 3788955 bytes, checksum: b005e5fd7bcddd43613e8d3de47b9e6c (MD5) Previous issue date: 2016-07-28 / Capes / Um método baseado nos harmônicos de baixa ordem para detecção de faltas de alta impedância (FAI) é proposto nessa dissertação. A Short-Time Fourier Transform (STFT) é empregada para extração dos principais componentes harmônicos da corrente de fase proveniente de uma FAI, os quais são utilizados para identificar a ocorrência desse tipo de falta. Adicionalmente apresenta-se uma análise do tamanho e tipo da janela utilizada na transformada e sua adequação à aplicação. Para validação do método, duas bases de dados foram utilizadas: uma base contendo sinais simulados de FAI, chaveamento de bancos de capacitores e energização de linhas, e outra base contendo apenas registros oscilográficos reais de FAI. O método proposto é capaz de detectar a ocorrência de FAI em diferentes pontos do sistema, para diversos tipos de superfícies de solo e conseguiu também distinguir FAI dos outros distúrbios. Além disso, o método é tolerante aos ruídos que são próprios dos sinais reais, uma vez que se mostrou eficaz em todos os casos aos quais foram aplicados. / A method to detect high impedance faults (HIF) based on the low order harmonics is proposed on this dissertation. The Short-Time Fourier Transform (STFT) is used to extract the main harmonic components of the phase current, which are used to identify a HIF occurrence. Additionally, the work presents an analysis on the window size and type used in the STFT and its suitability for the application. The method is validated using two databases: one containing HIF simulated signals mixed up with capacitor banks switching and feeder energizing singals, and another containing only actual HIF oscillograms. The proposed method is able to detect HIF occurring in various points of the test-system, as well as HIF happening on different types of soil surfaces. It is also able to distinguish HIF from the other tested disturbances. Futhermore, the method tolerates typical noises present on real signals, since it proved to be effective in all the applied cases.
14

Localizador digital de faltas para linhas de transmissão de múltiplos terminais / not available

Elenilton Teodoro Domingues 15 May 1998 (has links)
Este trabalho apresenta um método para calcular a localização de faltas em linhas de transmissão de alta tensão com três terminais. O método é baseado na utilização dos fasores de tensão e corrente trifásicos a 60 Hz, tomados nos terminais da linha e, faz uso da Transformada Discreta de Fourier (TDF) para flltragem digital das ondas. Subrotinas, como detecção da falta, sincronização dos dados provenientes dos diferentes terminais, extração dos fasores fundamentais e classificação da falta são também abordadas. O método é independente do tipo de falta e insensível às variações da impedância da fonte e a resistência de falta e também despreza a capacitância shunt da linha. A técnica proposta foi testada usando dados obtidos através de simulações do programa Alternative Transients Program (ATP), para uma variedade de condições, aplicando-se diversas localizações, resistências, ângulos de incidência e diferente tipos de faltas, a fim de cobrir as diversas situações comuns a uma linha de transmissão. Os resultados dos testes obtidos são apresentados e demonstraram um alto grau de precisão, destacando-se a confiabilidade e aplicabilidade do algoritmo proposto. / This work presents a method to calculate the fault location in three-terminal high voltage transmission lines. The method is based on the three-phase current and voltage 60 Hz phasors taken at the line terminals and it makes use of Discrete Fourier Transform (DFT) for digital filtering of the waves. Subroutines for fault detection, data synchronisation, extraction the fundamental phasors and fault classification are also described. The method is independent of fault type and insensitive to source impedance variation and fault resistance and totally ignores the lines shunt capacitance. The proposed technique was tested using data obtained through simulations of the Alternative Transients Program (ATP), for a variety of such as different location, fault resistance, inception angles and types of fault. The test results demonstrated a high degree of accuracy, reliability and applicability of the proposed algorithm.
15

Detecção e classificação de faltas de alta impedância em sistemas elétricos de potência usando lógica Fuzzy

Barros, Ana Claudia [UNESP] 18 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-18Bitstream added on 2014-06-13T18:08:27Z : No. of bitstreams: 1 barros_ac_me_ilha.pdf: 537823 bytes, checksum: 11c161179ae4dad9ba89c41455601030 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho tem por objetivo apresentar uma metodologia, para detecção e classificação de faltas de curto-circuito, direcionada para os eventos de alta impedância em subestações de energia elétrica. A detecção é executada por um cálculo algébrico simples via observação da diferença absoluta entre o valor eficaz médio estimado e o valor eficaz medido a partir da oscilografia das correntes trifásicas. Caso seja detectada a anomalia de corrente, procede-se a sua classificação baseada na lógica fuzzy. Trata-se de um problema que apresenta maiores dificuldades de identificação e classificação, tendo em vista que tais perturbações são sutis, o que se diferenciam em relação aos eventos caracterizados como de baixa e ou de média impedância. Os distúrbios de alta impedância, muitas vezes, não são detectados pelo sistema proteção. Neste caso, o sistema de proteção consideraos como uma operação em regime permanente, não distinguindo entre uma falta de alta impedância e um aumento/diminuição da corrente elétrica em decorrência das variações da demanda solicitada pelos consumidores. Ressalta-se que a metodologia, aqui proposta, segue os princípios formulados na referência Decanini (2008), com as devidas adaptações ao problema associado às faltas de alta impedância. A metodologia, proposta neste trabalho, usa dados oscilográficos que são processados de modo que a detecção e classificação das faltas possam ser estimadas através de um conjunto de características extraídas dos sinais de correntes. Este conjunto de característica é classificado pela lógica nebulosa e sua saída resulta na indicação do tipo da falta. Deve-se ressaltar que este algoritmo além de ser eficiente na detecção e classificação de faltas de alta impedância, sua eficiência destacase também na localização e detecção de faltas de baixa impedância... / This work presents a methodology to detect and classify short circuit faults principally for high impedance occurrences in electrical power systems. The detection is executed by a simple algebraic calculus observing the absolute difference with the efficient medium estimated value and the efficient value measured from the oscillogram of the three-phase currents. When a current anomaly is detected the classification is based on the fuzzy logic. It is a problem that presents some difficulties in identification and classification, considering that these perturbations are little which are different from the events characterized as low or medium impedance. The high impedance perturbations sometimes are not detected by the protection system. In this case, the protection system considers as one operation in steady state, and do not distinguish with a high impedance fault or an increasing/ decreasing of the electrical current due to the demand variation requested by the users. It is emphasized that the proposed methodology follows the fundamentals according the reference Decanini (2008), with the adaptations to the associated problem to the high impedance faults. The proposed methodology use oscillogram data that are processed in a way that the detection and classification of the faults are estimated by a set of characteristics from the current signals. This set is classified by logic fuzzy and the output results on the type of the fault. It is emphasized that this algorithm besides being efficient is detecting and classifying high impedance faults, is also efficient in localizing and detecting low impedance faults. The necessary data for the diagnosis of the faults were obtained by simulation of a radial feeder model with the ATP software. Results are satisfactory and show the viability of the proposed methodology that is faster for obtaining the solutions and is able to detect... (Complete abstract click electronic access below)
16

Contribui??es para a detec??o e identifica??o de faltas em inversores Multin?veis

Melo, Liviane Catarine Almeida 19 November 2008 (has links)
Made available in DSpace on 2015-03-03T15:07:32Z (GMT). No. of bitstreams: 1 LivianeCAM.pdf: 2271497 bytes, checksum: 4d8763a73b7fec60ad7f311e565d45b3 (MD5) Previous issue date: 2008-11-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This work presents contributions in the detection and identication of faults in multilevel inverters through the study of the converters behavior under these operation conditions. Basically, the approached fault consists of an open-circuit in any switch of a three-level clamped diode inverter. The converter operation is characterized in the pre and post-fault states. A wave form behavior analysis of the pole voltage, phase current and dc-bus current is also done, which highlights characteristics that allow the detection of failure and, even, under favorable conditions, the identication of the faulty device. A compensation strategy of the approached fault (open-switch) is also investigated with the purpose of maintaining the driving system operational when a failure occurs. The proposed topology uses SCRs in parallel with the internal switches of the inverter, which allows, in some occasions, the full utilization of the dc-bus / Este trabalho apresenta contribui??es para a detec??o e identica??o de faltas em inversores multin?veis, baseado no estudo do comportamento desse conversor sob essas condi??es de opera??o. Basicamente, a falta abordada consiste na abertura n?o comandada de uma das chaves de um inversor de tens?o de tr?s n?veis com diodos de grampeamento. O funcionamento do conversor ? caracterizado nos estados de pr? e p?s-falta. ?, tamb?m, feita uma an?lise dos comportamentos das formas de onda das tens?es de p?lo, corrente de fase e correntes do barramento CC, as quais apontam caracter?sticas que possibilitam detectar falta e, ainda, em condi??es favor?veis, identificar o dispositivo que apresentou defeito. Uma estrat?gia de compensa??o da falta abordada (chave aberta) tamb?m ? investigada, com o prop?sito de manter a continuidade de funcionamento do sistema de acionamento, quando da ocorr?ncia de uma falha. A topologia proposta utiliza SCRs em paralelo com as chaves internas do inversor, a qual permite, em algumas ocasi?es, a total utiliza??o do barramento CC
17

Identificação de faltas de alta impedância em sistemas de distribuição.

SANTOS, Wellinsílvio Costa dos. 07 May 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-05-07T20:46:33Z No. of bitstreams: 1 WELLINSÍLVIO COSTA DOS SANTOS – TESE (PPGEE) 2016.pdf: 10591682 bytes, checksum: 97299060f7fb8f9c7f837b25352da777 (MD5) / Made available in DSpace on 2018-05-07T20:46:33Z (GMT). No. of bitstreams: 1 WELLINSÍLVIO COSTA DOS SANTOS – TESE (PPGEE) 2016.pdf: 10591682 bytes, checksum: 97299060f7fb8f9c7f837b25352da777 (MD5) Previous issue date: 2016-08-15 / Capes / Uma técnica baseada em análise de transitórios eletromagnéticos é proposta para identificar faltas de alta impedância (FAI) em redes de distribuição. O algoritmo dispensa conhecimento dos parâmetros dos alimentadores e faz uso da transformada wavelet discreta (TWD) para monitorizar fenômenos transitórios associados a distúrbios no sistema de distribuição. A metodologia proposta é avaliada através de simulações em um programa de transitórios eletromagnéticos (EMTP) em um sistema de 13,8 kV, que foi modelado a partir de dados de uma rede de distribuição brasileira real. Além de FAI, foram simulados outros tipos de distúrbios, tais como faltas de baixa impedância, chaveamentos de novas linhas e bancos de capacitores. Os resultados obtidos demonstraram que o método é capaz de detectar a perturbação logo após o seu início e distingui-la de outros distúrbios, além de proporcionar uma redução significativa da região de localização da FAI. / An electromagnetic transient analysis-based technique is proposed to identify high impedance faults (HIF) in distribution networks. The algorithm dispenses knowledge of the feeder parameters and makes use of discrete wavelet transform (TWD) to monitor transient phenomena associated with disturbances in the distribution system. The proposed methodology is evaluated through simulations in an electromagnetic transient program (EMTP) in a 13.8 kV system, which was modeled from actual Brazilian distribution network data. Besides HIF, other types of disturbances were simulated, such as low impedance fault, and switching of lines and capacitor banks. Obtained results have shown that the method is able to detect the disturbance soon after its inception and distinguish it from other disorders, as well as providing a significant reduction in the region of its location for maintenance crews.
18

Modelos neurais autônomos para classificação e localização de defeitos em linhas de transmissão

Lopes, Daniel do Souto 03 July 2017 (has links)
Submitted by Patrícia Cerveira (pcerveira1@gmail.com) on 2017-05-29T17:39:15Z No. of bitstreams: 1 Daniel Souto Dissertação.pdf: 2907570 bytes, checksum: 0379fd854c367debb9d8b6237a881084 (MD5) / Rejected by Biblioteca da Escola de Engenharia (bee@ndc.uff.br), reason: Bom dia, Patrícia! Rejeitei este item, pois fiquei com dúvida se é realmente acesso restrito. Conforme orientações da Jane, o acesso é aberto. Você está colocando acesso restrito. O acesso somente é restrito quando a tese ou dissertação serão publicadas e se exige ineditismo, ou quando o produto do trabalho tem segredo empresarial ou virará patente. Nos demais casos, é aberto. Aguardo retorno. Atenciosamente, Catarina Ribeiro Bibliotecária BEE - Ramal 5992 on 2017-06-29T13:54:55Z (GMT) / Submitted by Patrícia Cerveira (pcerveira1@gmail.com) on 2017-06-29T18:56:23Z No. of bitstreams: 1 Daniel Souto Dissertação.pdf: 2907570 bytes, checksum: 0379fd854c367debb9d8b6237a881084 (MD5) / Approved for entry into archive by Biblioteca da Escola de Engenharia (bee@ndc.uff.br) on 2017-07-03T12:39:19Z (GMT) No. of bitstreams: 1 Daniel Souto Dissertação.pdf: 2907570 bytes, checksum: 0379fd854c367debb9d8b6237a881084 (MD5) / Made available in DSpace on 2017-07-03T12:39:19Z (GMT). No. of bitstreams: 1 Daniel Souto Dissertação.pdf: 2907570 bytes, checksum: 0379fd854c367debb9d8b6237a881084 (MD5) / O problema de diagnóstico de faltas em linhas de transmissão constitui um dos principais desafios para gestão técnica de instalações de transmissão. A assertividade nesta atividade é fundamental para suporte à tomada de decisão, reduzindo as taxas de indisponibilidade e promovendo o restabelecimento célere da função transmissão, contribuindo para melhoria da qualidade do serviço e reduzindo os impactos financeiros advindos de reduções na parcela variável. Este documento apresenta uma proposta de sistema inteligente para classificação e localização de faltas em linhas de transmissão. Os algoritmos utilizados são baseados nos chamados modelos neurais autônomos, que incluem técnicas analíticas para seleção de entradas e especificação automática da estrutura sem a necessidade do uso de um conjunto independente de dados para validação. Ao utilizar a inferência bayesiana para especificação e treinamento de perceptrons de múltiplas camadas (MLPs), o sistema inteligente fornece respostas probabilísticas para classificação do tipo de defeito e também para a distância da falta em relação à subestação monitorada. Para desenvolvimento dos modelos são utilizados dados técnicos de uma linha de transmissão integrante do Sistema Interligado Nacional (SIN), a qual é modelada em um “software” de simulação de transitórios eletromagnéticos, ATP, visando estabelecer os diversos cenários de falta. Foram analisados dois tipos de rede equivalente, uma detalhada e outra simples, de forma a precisar qual o melhor modelo e se há diferenças significativas nos resultados em termos de representação das faltas. As bases de dados com as oscilografias de tensão e corrente obtidas para cada tipo de defeito são utilizadas para treinamento e teste do sistema inteligente, sendo demonstrando o potencial dos algoritmos utilizados. / The problem of fault diagnosis in transmission lines is one of the main challenges for the technical management of transmission facilities. The assertiveness on this activity is crucial to support decision making, reducing unavailability rates and promoting rapid reinstatement of the transmission function, contributing to the improvement of service quality and reducing the financial impacts arising from reductions in the variable portion. This document presents a proposal of intelligent system for classification and location of faults in transmission lines. The algorithms used are based on the so-called autonomous neural models which include analytical techniques for input selection and automatic structure specification without the need for an independent set of data for validation. Using Bayesian inference for specification and training of multilayer perceptrons (MLPs), the intelligent system provides probabilistic responses for classification of the type of fault and also for the distance of the fault from the monitored substation. Thus for the development of the models, technical data are used of a transmission line that is part of the National Interconnected System (SIN) which is modeled in an electromagnetic transient simulation software, ATP, aiming to establish the various fault scenarios. Furthermore, two types of equivalent network were analyzed, one detailed and one simple, in order to specify the best model and if there were significant differences in results in terms of fault representation. The databases with voltage and current oscillographs obtained for each type of fault are used for training and testing of the intelligent system, demonstrating the potential of the algorithms used.
19

Avaliação da técnica de decomposição por componentes ortogonais para identificação de faltas de alta impedância / Evaluation of the orthogonal decomposition technique for high impedance fault detection

Picchi, Daniel da Costa 18 May 2018 (has links)
Este trabalho apresenta o estado da arte das técnicas mais aplicadas para localização de faltas e modelagem de faltas de alta impedância e propõe a utilização de uma recente técnica baseada na decomposição dos sinais em componentes ortogonais. Este estudo avalia a aplicabilidade da técnica proposta utilizando dados reais de um sistema de distribuição de energia brasileiro, além de apresentar os conceitos teóricos sobre a decomposição em componentes ortogonais. / This work presents the state of the art of the most used techniques for locating and modelling high impedance faults and proposes the use of a recent technique based on the decomposition of the signals in orthogonal components. The objective of this study is to evaluate the application of the proposed technique using real data from a Brazilian distribution network, and presents the theory on orthogonal decomposition.
20

A detecção e a localização de faltas de alta impedância em sistemas de distribuição utilizando transformadas wavelets e redes neurais artificiais / Detection and location of high impedance faults in distribution systems using wavelets transforms and artificial neural networks

Fanucchi, Rodrigo Zempulski 01 September 2014 (has links)
A ocorrência de faltas em sistemas elétricos de distribuição de energia é algo indesejável, porém, inerente ao mesmo devido a sua topologia normalmente aérea. Entre essas faltas, destacam-se as de alta impedância devido às características de corrente de baixa magnitude que surgem quando de sua ocorrência. No presente trabalho, um método baseado em três módulos é apresentado para a detecção e localização de faltas de alta impedância (FAI). No Módulo 1, é realizado um monitoramento contínuo dos sinais de corrente de forma a detectar a ocorrência de uma descontinuidade que pode estar vinculada a ocorrência de uma FAI. Caso haja essa detecção, o Módulo 2 é ativado de forma a analisar se o evento é realmente uma FAI. Por último, depois de detectada a FAI, o Módulo 3 é inicializado e a localização da falta, estimada. Para possibilitar a análise do método proposto e validar os resultados obtidos, um sistema de distribuição real, em conjunto com todas as etapas do sistema de aquisição de dados, foi modelado no software ATP/EMTP. Essa modelagem foi validada a partir de dados reais obtidos quando da ocorrência em campo de um curto-circuito bifásico. Vale ressaltar que um estudo de caso referente à importância da detecção e localização de um evento relacionado a uma FAI em uma concessionária de energia foi também analisado no início do trabalho de forma a mostrar o possível impacto da localização de FAIs nos indicadores de qualidade de serviço na mesma. Pelos resultados observados, a abordagem como um todo se mostra promissora e passível de aplicação no sistema real simulado e avaliado. / The occurrence of faults in overhead distribution networks is undesirable but common based on its topology. Among these events, High Impedance Faults (HIF) is one of the most important due to the fact that it has a small magnitude current. In this dissertation, a modular three-phase method is presented to enable HIF´s detection and location in a distribution system. In the Module 1, the phase currents are monitored in order to detect a discontinuity that can be associated with a HIF´s occurrence. If the Module 1 detected a discontinuity, the Module 2 is initiated and it analyses if the event can be classified as a HIF. Finally, if the Module 2 returns the event as a HIF, the Module 3 is initiated and the possible location of the HIF is estimated. To enable analysis of the proposed method and to validate the results, a real-based distribution system and the acquisition system of a digital relay were modeled in ATP/EMTP software. In order to validate the model, a simulated twophase fault were compared with the data obtained in a real event occurred in the analyzed distribution system. In order to present the importance of detecting and locating a HIF to a distribution utility, a case study was developed in the beginning of its work. Its importance is based on the improvement of the service quality indicators. Based on the results, the proposed method seems to be promising and applicable in a real distribution system.

Page generated in 0.0442 seconds