• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 183
  • 5
  • 4
  • 2
  • 2
  • Tagged with
  • 198
  • 198
  • 183
  • 117
  • 112
  • 101
  • 74
  • 73
  • 67
  • 50
  • 39
  • 38
  • 35
  • 32
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Desarrollo de nuevas metodologías ecológicas aplicadas al análisis clínico

Baile, Paola 18 November 2019 (has links)
La finalidad de la presente memoria consiste en el desarrollo y la evaluación de métodos analíticos rápidos, sencillos, sensibles, económicos y respetuosos con el medio ambiente para su aplicación al análisis clínico. Para tal fin, se ha estudiado en profundidad la aplicabilidad de la zeolita sintética ZSM-5 como material microporoso sorbente en la técnica de extracción en fase sólida magnética dispersiva, presentando en algunos capítulos ciertas variantes. Para ello, por un lado, se ha sintetizado la zeolita ZSM-5 decorada con partículas magnéticas de óxido de hierro (ZSM-5/Fe2O3) lo que le confiere propiedades magnéticas y, por consiguiente, una fácil manipulación bajo la acción de un campo magnético externo. Y por otro lado, se ha modificado la superficie del sorbente ZSM-5/Fe2O3 con diferentes grupos funcionales para mejorar la capacidad de extracción del mismo y conseguir así una mayor sensibilidad y selectividad en los métodos desarrollados. Además, se ha presentado otro material extractante basado en nanopartículas magnéticas de óxido de hierro, siguiendo el hilo conductor de la presente memoria. El reto de la Química Analítica en las últimas décadas ha sido avanzar en las líneas de la miniaturización, la automatización, la simplificación y la portabilidad. En la presente memoria, por un lado, se ha seleccionado la extracción en fase sólida magnética dispersiva frente a otras técnicas de extracción en fase sólida por las ventajas que ésta presenta en la línea de la miniaturización, simplificación y la portabilidad. Y por otro lado, los métodos desarrollados en los primeros capítulos hacen uso de sistemas de separación/detección tradicionales y voluminosos como la espectrometría de emisión óptica con plasma de acoplamiento inductivo y la cromatografía de líquidos con un detector espectrofotométrico de fila de diodos; mientras que en los últimos capítulos se emplean electrodos serigrafiados y espectrofotometría ultravioleta-visible, los cuales van en la línea de la miniaturización y la portabilidad. Para cumplir con los objetivos propuestos, la presente memoria recoge cinco trabajos de investigación distribuidos en cinco capítulos, los cuales se describen brevemente a continuación: - Capítulo 1: se presenta el sorbente magnético ZSM-5/Fe2O3 modificado superficialmente con el surfactante bromuro de hexadeciltrimetilamonio y el agente quelante dietilditiocarbamato trihidrato de sodio para la simultánea separación y preconcentración de Cd, Hg y Pb en muestras de orina, empleando la extracción en fase sólida magnética dispersiva, y su posterior detección mediante espectrometría de emisión óptica con plasma de acoplamiento inductivo. - Capítulos 2 y 3: se presenta el sorbente magnético ZSM-5/Fe2O3 modificado superficialmente con el surfactante bromuro de hexadeciltrimetilamonio para la determinación de fármacos antiiflamatorios no esteroideos en el Capítulo 2 y, de bisfenoles en el Capítulo 3, tanto en muestras reales de orina como de agua mediante la extracción en fase sólida magnética dispersiva seguida de la cromatografía de líquidos con un detector espectrofotométrico de fila de diodos. - Capítulo 4: se presenta una modalidad de la extracción en fase sólida magnética dispersiva, empleando el sorbente ZSM-5/Fe2O3, asociada con electrodos serigrafiados para la determinación de Cd en muestras de orina. - Capítulo 5: en este último capítulo se presenta un nuevo sorbente basado en nanopartículas magnéticas de óxido de hierro para la extracción de glucosa en una matriz extracelular simulada (i.e., gel de agarosa basado en fluido intersticial sintético). Esta investigación se realizó en la School of Chemical Sciencies de la Dublin City University (Irlanda).
152

Sensibilización de la técnica Espectroscopía de Plasmas Producidos por Laser para el análisis de muestras líquidas mediante el uso de procedimientos de preparación de la muestra eficientes y fácilmente automatizables

Ripoll-Seguer, Laura 28 October 2020 (has links)
Hoy en día, como consecuencia del gran desarrollo de las metodologías de análisis, han surgido nuevas necesidades analíticas que son cada vez más exigentes, demandando análisis rápidos, fiables, in-situ, ecológicos y con instrumentación relativamente de bajo coste. Para cumplir estos ambiciosos objetivos, las nuevas tendencias de la química analítica van encaminadas hacia la miniaturización de las metodologías de análisis y el uso de detectores disponibles en formato compacto. La espectrometría de plasmas producidos por láser (Laser-Induced Breakdown Spectrometry, LIBS), es una técnica que presenta unas características que podrían cumplir con estas nuevas necesidades analíticas y que son difícilmente abordables por otras técnicas de análisis establecidas más sensibles, pero más complejas y costosas. LIBS es una técnica de análisis elemental que emplea como fuente de excitación un láser altamente energético que es enfocado en un pequeño punto de tamaño submilimétrico de la muestra, provocando la generación de un intenso plasma que se caracteriza por una elevada temperatura y densidad electrónica (plasma inducido por láser). En el seno de este plasma, el material objeto de análisis es vaporizado, reducido a su forma elemental y excitado. Las especies emisoras (iones o átomos neutros) se identifican resolviendo espectral y temporalmente la emisión del plasma, lo que se utiliza para obtener información cuantitativa y/o cualitativa sobre la composición elemental de la muestra. Mediante esta técnica, es posible analizar cualquier sustancia independientemente del estado de agregación en que se encuentre sin la necesidad de condiciones ambientales específicas para su uso (i.e., utilización de gases especiales (Ar, He, etc.) o condiciones de baja presión o vacío), lo que simplifica y abarata tanto el coste del análisis como de la instrumentación requerida. Además, teniendo en cuenta que un espectro LIBS puede ser adquirido en tiempos del orden de microsegundos, puede considerarse una técnica de análisis rápida que, adicionalmente, proporciona información multielemental. También es extremadamente flexible desde el punto de vista experimental, ya que todos sus componentes (láseres, detector, óptica, electrónica, etc.) pueden ser miniaturizados y el sistema completo puede ser fácilmente automatizado, lo que la hace especialmente interesante para su aplicación al análisis en línea e in-situ. Por todas estas características, la técnica LIBS es muy atractiva desde el punto de vista de las nuevas tendencias de la química analítica. Por otra parte, como cualquier técnica analítica, posee una serie de limitaciones. Aunque en principio, la técnica LIBS puede ser utilizada para el análisis de muestras de muy distinta naturaleza (sólidas, líquidas, gaseosas o aerosoles), lo cierto es que su principal campo de aplicación ha sido fundamentalmente el análisis de muestras sólidas. Este hecho se debe principalmente a la baja sensibilidad y reproducibilidad del análisis LIBS de líquidos. Esta falta de sensibilidad se debe principalmente a la diferente evolución del plasma LIBS cuando se encuentra confinado en un medio líquido. La duración del plasma debido a este efecto de confinamiento es menor, reduciendo también el tiempo de vida del estado excitado de los analitos y resultando en una señal más difícil de separar del fondo continuo de emisión. Además, una elevada porción de la energía "del plasma" generado es disipada como energía “no radiante”. Por una parte, debido a los fuertes efectos mecánicos que se producen al inducir el plasma en la densa masa líquida (i.e., onda de choque, burbuja de cavitación, etc.) y, por otra, debido a la vaporización de líquido, quedando sólo una pequeña fracción de energía que puede convertirse en energía radiativa. Estas limitaciones en la sensibilidad han sido abordadas en la literatura mediante el desarrollo de diferentes estrategias experimentales para el análisis LIBS de líquidos (i.e., análisis mediante la técnica LIBS de doble impulso, conversión de la muestra líquida a sustrato sólido, etc.). Pese a estos esfuerzos, este aumento de la sensibilidad ha sido, hasta la fecha, o bien insuficiente, o bien logrado mediante procedimientos de preparación de muestras complejos, con diversas etapas y difíciles de automatizar. Por este motivo, el objetivo fundamental de este trabajo de tesis doctoral ha sido la sensibilización de la técnica LIBS mediante la obtención de nuevos métodos de preparación de la muestra que puedan ser combinados con LIBS y que resulten simples, miniaturizados o fácilmente miniaturizables, y con posibilidades de automatización. De esta forma, se busca extender la aplicabilidad de LIBS para el análisis de “elementos traza” en muestras líquidas que puedan ser utilizados in-situ. En el capítulo 3 de esta memoria de tesis se ha evaluado la combinación de LIBS con una técnica de nebulización automática que permite la creación de películas sólidas homogéneas a partir de muestras líquidas, la deposición por electrospray. De esta forma, se realiza una conversión automática de la muestra líquida a matriz sólida que puede ser directamente interrogada por el sistema LIBS, sin necesidad de etapas intermedias entre la preparación de la muestra y la detección. Las películas finas obtenidas pueden ser directamente interrogadas por el sistema LIBS. Por otra parte, en los capítulos 4, 5 y 6 se ha evaluado la combinación de metodologías de microextracción en fase sólida con LIBS, ya que estas nuevas técnicas han demostrado ser rápidas, ecológicas y altamente eficientes en la extracción de los analitos de interés de las muestras líquidas. Además, son especialmente interesantes para ser combinadas con LIBS, ya que los analitos quedan retenidos directamente en una matriz sólida que puede ser fácilmente interrogada por LIBS, sin la necesidad de realizar la etapa de desorción o elución de los analitos requerida con otras técnicas de detección convencionales. De esta forma, en el Capítulo 4 se ha evaluado el uso de un material adsorbente de elevada eficiencia (i.e., el óxido de grafeno) para su uso en un procedimiento de microextracción en fase sólida en modalidad dispersiva (DSPME), y se ha comparado con un material clásicamente utilizado en extracción, el carbón activo; demostrándose las ventajas del uso de óxido de grafeno para el análisis de trazas mediante DSPME-LIBS. En los capítulos 5 y 6 se ha evaluado la combinación de la modalidad de microextracción en película delgada con la detección por LIBS (TFME-LIBS), ya que es un procedimiento eficiente y fácilmente automatizable. Pese a estas ventajas, las características morfológicas de las películas adsorbentes tienen un papel muy importante tanto en la etapa de microextracción como en la detección LIBS. Por este motivo, en estos dos últimos capítulos se han estudiado diversas modalidades de generación de películas finas para TFME, así como las capacidades analíticas de los procedimientos TFME-LIBS desarrollados.
153

Desenvolvimento da fase extratora SPME de poli(pirrol) e avaliação das técnicas SPME/LC e SBSE/LC para análises de antidepressivos em amostras de plasma / Developmento of polypyrrole SPME extraction phase and evaluation of the SPME/LC and SBSE/LC techniques to antidepressants plasma samples analyses

Chaves, Andréa Rodrigues 27 June 2008 (has links)
A depressão em idosos é uma desordem persistente e recorrente, resultado do stress psicossocial ou efeito de doenças fisiológicas, que podem acarretar a desabilidade do indivíduo, aumento dos sintomas das doenças clínicas, na maior utilização dos serviços de saúde e altas taxas de suicídios.A monitorização terapêutica permite a ndividualização do regime de dosagem, assegurando a eficácia clínica e minimizando os efeitos adversos dos fármacos, prescritos na clínica. Os antidepressivos têm sido monitorados, pois, apresentam intervalos terapêuticos bem estabelecidos, ou seja, a maioria dos pacientes, que apresentam concentrações plasmáticas dentro deste intervalo fixo, tem as desordens psiquiátricas mantidas sob controle e efeitos adversos aceitáveis. Os antidepressivos tricíclicos (ADTs): imipramina, amitriptilina, nortriptilina e desipramina, embora eficazes e ainda muito utilizados, apresentam efeitos adversos, não desejáveis. Os antidepressivos, inibidores seletivos da recaptação de serotonina (SSRIs): citalopram, fluoxetina, paroxetina e sertralina, apresentam eficácia clínica comparável aos clássicos ADTs, mas destituídos dos efeitos adversos associados aos mesmos. Os métodos convencionais, empregados no tratamento de amostras biológicas, para análises de antidepressivos por técnicas cromatográficas, têm sido a extração líquido-líquido e extração em fase sólida. A microextração em fase sólida tem sido empregada em diferentes análises em fluidos biológicos, porém essa técnica apresenta certas limitações como, o número limitado de fases extratoras disponíveis no comércio que sejam adequadas para a análise de compostos não iônicos. A avaliação de novas fases extratoras, mais seletivas, estáveis e de baixo custo tem sido requerida para a análise de fármacos. O interesse no uso de poli(pirrol) (PPY), como fase extratora para SPME, está relacionado às diferentes interações dos fármacos (hidrofóbicas, -, com o grupo funcional polar, troca iônica, ácido-base) aos grupos multifuncionais deste polímero. Sua polimerização pode ser alcançada tanto por oxidação química, quanto por eletrodeposição em meio aquoso ou orgânico. O método eletroquímico apresenta algumas vantagens, tais como: o polímero ou mistura de polimeros podem ser revestidos diretamente em um metal, incorporação de diferentes grupos funcionais, entre outras, a polimerização pode ser eletroquimicamente controlada através da voltametria cíclica. Neste trabalho o poli(pirrol) (PPY) foi eletrodepositado em eletrodo de aço inox e empregado para a microextração em fase sólida dos antidepressivos: paroxetina, fluoxetina, mirtazapina, duloxetina, sertralina e citalopram. As variáveis da eletrodeposição, número de ciclos e contra-íon empregado no processo de eletrodeposição foram otimizadas. Assim como as variáveis SPME: tempo, temperatura, pH e volume de amostra, e tempo e solvente de dessorção; almejando maior sensibilidade para o método SPME-PPY/LC UV proposto. A extração sortiva em barra de agitação (SBSE), técnica recente de preparo de amostras, para a pré-concentração de compostos orgânicos presentes em amostras biológicas, baseia-se na extração estática, através do polímero polidimetilsiloxano (PDMS), no qual ocorre a dissolução (sorção) do analito. Neste trabalho, as técnicas SBSE e cromatografia líquida de alta eficiência com detecção UV (SBSE/LC UV) foram avaliadas para a análise simultânea de antidepressivos em amostras de plasma para fins de monitorização terapêutica. As condições cromatográficas de análise, assim como as variáveis SBSE de extração (tempo, temperatura, força iônica, pH da matriz) e tempo de dessorção, foram otimizadas, visando adequada sensibilidade analítica. A validação analítica foi realizada segundo normas da ANVISA, para ambos os métodos propostos, em diferentes concentrações plasmáticas, as quais contemplam o intervalo terapêutico. Segundo os parâmetros de validação avaliados, os métodos SBSE/LCUV e SPMEPPY/LCUV padronizados poderão ser empregados nas análises dos antidepressivos, para fins de monitorização terapêutica. / Depression in the elderly is a persistent and recurrent disorder resulting from psychosocial stress or physiological effect or disease. This condition can lead to disability, cognitive impairment, enhanced symptoms of medical illnesses, increased use of health care services and, increased of suicide rates. Therapeutic monitoring allows individualization of the dose regimen, ensuring clinical effectiveness and minimizing the adverse effects of drugs, prescribed at the clinic. Antidepressants have been monitored because they present well - established therapeutic intervals; in other words, most of the patients present plasmatic concentrations within this fixed range, so that their psychiatric disorders are kept under control and the adverse effects are acceptable. The tricyclic antidepressants (ADTs) imipramine, amitriptyline, nortryptiline, and desipramine, have adverse effects. The selective serotonin reuptake inhibitors (SSRIs) antidepressants citalopram, fluoxetine, paroxetine, and sertraline, are clinically effectiveness as the classic ADTs, but they do not lead to the adverse effects associated to the latter. The conventional methods employed in the treatment of biological samples for analysis of antidepressants by chromatographic techniques have been the liquid-liquid extraction (LLE) and solid phase extraction (SPE) techniques. Solid-phase microextraction (SPME) has been used in various analyses of biological fluids. However, this technique has limitations such as the small number of comemercially available extracting phases that are appropriate for the analysis of non-ionic compounds. Investigation of new extraction phases that are more selective and stable, as well as inexpensive, has been requested for drug analysis. The interest in the use of poly(pirrole) (PPY) as an extraction phase for SPME is related to the different interactions of the drugs (hydrophobic, - , with the polar functional group, ionic exchange and acid-base) with the multifunctional groups on this polymer. The PPY polymerization can be achieved by chemical oxidation or electropolymerization in aqueous solution or organic solvents. The electrochemical method has advantages such as, the polymer or a mixes of polymers can be directly deposited on a metal wire, different functional groups can be incorporated, polymerization can be electrochemically controlled by cyclic voltammetry. In this work poly(pyrrole) was electropolymerized on stainless steel electrodes and employed for the solid phase microextraction of the antidepressants paroxetine, fluoxetine, mirtazapine, duloxetine, sertraline, and citalopram. The electropolymerization variables, the number of cycles and counterion employed in the process were optimized, as well as the SPME variables, time, temperature, pH, sample volume, and desorption solvent; aiming at a better sensibility for the proposed method SPME-PPY/LC-UV. The stir bar sorptive extraction (SBSE), recently established technique for samples preparation, that targets the pre concentration of organic compounds present in biological samples. It is based on static extraction, through the polymeric polydimethylsiloxane (PDMS), where there is analyte dissolution (sorption). In this work, the SBSE technique and liquid chromatography with UV detector (SBSE/LC-UV) were evaluated for the simultaneous determination of antidepressants in plasma samples for therapeutic monitoring purposes. The cromatographic conditions, the SBSE extraction variables (time, temperature, ionic strength and matrix pH), and the dessorption time were optimized for appropriate analytical sensibility. The analytical validation was accomplished according to the norms of ANVISA for both of the proposed methods, in different plasmatic concentrations, which contemplate the therapeutic interval. According to the evaluated validation parameters, the standardized methods SBSE/LC-UV and SPME-PPY/LC-UV can be used in the analyses of antidepressants for therapeutic drug monitoring purposes.
154

Desenvolvimento de métodos de extração e determinação de bifenilas policloradas por cromatografia gasosa e detector de captura de elétrons em óleo Ascarel, reator anaeróbio e solo / Development and validation of a method for determination of Polychlorinated Biphenyls (PCBs) of a standard solution PCB Congener MIX 1 by gas chromatography and electron capture detector in three different matrices: Askarel oil, samples from batch anaerobic reactors and soil

Adorno, Maria Angela Tallarico 23 August 2013 (has links)
Bifenilas policloradas (PCBs) são componentes de óleo ascarel, usado extensamente (no Brasil até os anos 80) como isolante em transformadores de energia devido às suas propriedades físico-químicas como estabilidade térmica e alta constante dielétrica. Apesar de ter sido proibido em todo o mundo devido à alta toxicidade dos PCBs presentes em sua composição, ainda resta grande quantidade de ascarel em circulação como resíduo \"passivo\" e resultante de contaminação em trocas dos fluidos dos transformadores, além de vazamentos. A principal forma de eliminação é por incineração, que, além de ser um processo caro, pode provocar a formação de compostos mais tóxicos, as dioxinas. Por isso é importante o monitoramento da concentração dessas substâncias, a fim de evitar maiores impactos ambientais na sua disposição, bem como em estudos de biodegradação. Esta matriz é extremamente complexa, o que torna a extração e determinação desses analitos um processo trabalhoso e difícil. Neste trabalho avaliaram-se métodos de extração e determinação de PCBs presentes na solução padrão comercial PCB Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). O desenvolvimento de métodos de extração (cromatografia em coluna, extração líquido-líquido (L-L), extração em fase sólida (SPE) e micro-extração em fase sólida - SPME) dos PCBs foi seguido da determinação, por cromatografia gasosa com detector por captura de elétrons (CG/DCE), em três matrizes diferentes: óleo ascarel, amostras provenientes de reatores anaeróbios em batelada e solo. Os métodos cuja purificação e extração diminuíram o efeito dos interferentes da matriz, como SPE - Sulfoxide, cromatografia em coluna de sílica e extração L-L com n-hexano foram validados pela avaliação dos seguintes parâmetros: linearidade e faixa de aplicação; precisão instrumental; limite de detecção, limite de quantificação e recuperação absoluta. O critério de escolha entre os métodos para extração dos PCBs do óleo que forneceram maior eficiência (cartucho SPE Sulfoxide e coluna de sílica gel, após lavagem ácida; método da adição de padrão, entre 1,0 e 4,0 mg L-1) deve considerar a disponibilidade de recursos, pois a sílica gel é mais viável economicamente do que o cartucho SPE. Os valores de R2 > 0,99 para o método de extração com sílica, mesmo tendo sido considerados apenas três pontos para a curva de calibração, atestam maior linearidade do que o método com SPE Sulfoxide (R2 entre 0,97 e 0,99). A extração L-L e determinação por CG/DCE dos PCBs (padronização interna) de amostras provenientes de reatores anaeróbios em batelada (aquosas, em matriz extremamente complexa com biomassa e espuma de poliuretano para imobilização de microrganismos) foram eficientes na faixa de concentração entre 0,05 e 0,5 mg L-1. Esse método foi adequado para monitorar PCBs em estudo de degradação anaeróbia e teste de adsorção dos PCBs em espuma; forneceu linearidade com R2 entre 0,93 e 0,96 e limites de detecção de 0,048 a 0,298 mg L-1, além de recuperação absoluta entre 14,1% e 110,7%. As condições testadas por SPME não permitiram a extração dos PCBs de óleo e de solo, principalmente devido à dessorção incompleta dos PCBs da fibra de polidimetil-siloxano, de 100 μm. / Polychlorinated biphenyls (PCBs) are components of ascarel, oil widely used as insulation (until the \'80s in Brazil) due to its physicochemical properties such as thermal stability and high dielectric constant. Despite having been banned worldwide due to the high toxicity of PCBs present in its composition, there are still lots of outstanding ascarel as \"passive\" residue and resulting contamination of fluids in transformers exchanges, plus leaks. The main form of disposal is incineration, which, besides being costly, can cause the formation of more toxic compounds, that is, dioxins. It is therefore important to monitor the concentration of these substances in order to prevent further environmental impacts in their disposal, as well as in studies of biodegradation. This is an extremely complex matrix, which makes the extraction and determination of this analytes very difficult and labor intensive. In this work we have evaluated methods of extraction and determination of the PCBs present in the standard solution Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). The extraction and cleanup developed methods which reduced the effects of interfering matrix as solid phase extraction (SPE) - Sulfoxide, column chromatography on silica and liquid-liquid (L-L) extraction with n-hexane, and solid phase microextraction (SPME) after determination of the PCBs by gas chromatography with electron capture detector (GC/ECD) were validated by assessing the following parameters: linearity and range of application; instrumental precision; detection limit; limit of quantification and absolute recovery. The criterion for choosing between the methods for extraction of PCBs from the oil with a higher efficiency (SPE cartridge Sulfoxide and silica gel column, after acid washing; using the standard addition method, between 1.0 and 4.0 mg L-1) must evaluate the availability resources, since the silica gel is more economically viable than the SPE cartridge. The R2 values > 0.99 for silica extraction method, even though it was considered only three points for the calibration curve, attested higher linearity than the method with SPE Sulfoxide (R2 between 0.97 and 0.99). The L-L extraction and determination by GC/ECD of the PCBs (internal standardization) of samples from batch anaerobic reactors (aqueous, in a very complex matrix with biomass and polyurethane foam for the immobilization of microorganisms) were efficient in the concentration range between 0.05 and 0.5 mg L-1. This method was suitable to monitor PCBs in anaerobic degradation studies and its adsorption on foam; provided R2 linearity between 0.93 and 0.96 and detection limits from 0.048 to 0.298 mg L-1, as well as absolute recovery between 14.1% and 110.7%. The conditions tested for SPME technique did not allow the extraction of the PCBs from the oil and soil, mainly due to the \"incomplete dessorption\" of PCBs from the polydimethylsiloxane fiber of 100 micron.
155

Novas abordagens para exploração de reações químicas relativamente lentas em sistemas de análises em fluxo. Aplicações a amostras de relevância agronômica e ambiental / Novel approaches for exploiting relatively slow chemical reactions in flow analysis systems. Applications to relevant agronomic and environmental samples

Vida, Ana Clara Felix 27 November 2015 (has links)
Diferentes estratégias foram projetadas e desenvolvidas para sistemas de análises em fluxo envolvendo reações químicas relativamente lentas. O aprisionamento da zona da amostra na bobina de reação permite melhorias de sensibilidade em métodos espectrofotométricos em fluxo envolvendo reações catalíticas. Uma característica inerente a esta estratégia é que, de acordo com as baixas concentrações do analito de interesse esperadas nas amostras, pode-se explorar tanto a variação do tempo quanto da temperatura de aquecimento para o desenvolvimento reacional. Esta estratégia evita a geração de bolhas de ar quando temperaturas elevadas são empregadas. O aprisionamento da zona da amostra na bobina de reação em sistema de análises por injeção em fluxo foi aplicado à reação de oxidação do reagente Tiron por peróxido de hidrogênio catalisada por Co(II) para determinação espectrofotométrica de cobalto em gramíneas. O sistema apresentou boas figuras de mérito, tais como repetibilidade [d.p.r. = 0,8% para 0,6 ?g L-1 Co(II), (n = 5)], limite de detecção [0,046 ?g L-1 Co(II)], frequência de amostragem (19 h-1) e consumo de reagente (330 ?g de Tiron por determinação). Os dados de recuperação nas amostras de gramíneas digeridas variaram entre 97% e 113%. O aquecimento explorando o aprisionamento da zona da amostra na cubeta de detecção mostrou-se promissor para implementação de reações relativamente lentas sem a geração de bolhas de ar, e não houve liberação de bolhas mesmo sob a temperatura de 95ºC. Esta estratégia foi aplicada à determinação espectrofotométrica de vanádio em águas minerais envolvendo a oxidação de p-anisidina por bromato catalisada por V(V) e ativada por Tiron. Sob temperatura de 95ºC, boas figuras de mérito foram obtidas, tais como limite de detecção (0,1 ?g L-1), repetibilidade [d.p.r. = 2,1 % para 5,0 ?g L-1 (n = 10)], frequência analítica [25 h-1] e consumo de reagente (3,0 mg de p-anisidina por determinação). Adicionalmente, foi desenvolvido um procedimento analítico em fluxo para monitoramento dos resíduos de ametrina e atrazina potencialmente lixiviáveis em solos, envolvendo também um processo relativamente lento. Um sistema de análises por injeção sequencial foi utilizado para as etapas de dessorção dos herbicidas com solução 0,01 mol L-1 CaCl2 e concentração em fase sólida em linha, seguida da eluição dessas espécies para a separação em uma coluna monolítica C18 conectada a um cromatógrafo líquido por meio de uma válvula de seis vias. Os eluatos eram injetados no cromatógrafo por meio de uma alça de amostragem de 300 ?L conectada à válvula. Boas figuras de mérito foram obtidas, tais como fatores de enriquecimento de 10,2 e 18,8 e limites de detecção de 0,016 e 0,015 mg L-1 para ametrina e atrazina, respectivamente, limite de quantificação de 0,05 mg L-1 para ambos os herbicidas e repetibilidade estimada como 6,3% e 5,1% para 0,05 mg L-1 (n = 10) para ametrina e atrazina, respecivamente. Os dados de adição e recuperação dos herbicidas nos extratos de solos em condições de equilíbrio se situaram na faixa de 85 a 99% / Different approaches to analytical flow systems involving relatively slow chemical reactions were developed. Zone trapping inside the reaction coil enables sensitivity improvements in flow-based spectrophotometric procedures relying on catalytic reactions. The reaction time and/or temperature can be increased for the determination of analytes present in the samples at low concentrations. Exploitation of the strategy avoids the liberation of air bubbles in the analytical path when high temperatures are involved. A flow injection system with zone trapping in the main reactor was developed for the spectrophotometric determination of cobalt in grass samples exploiting the oxidation of Tiron by bromate catalised by Co(II). Good figures of merit such as repeatability [r.s.d. = 0.8% for 0.6 ?g L-1 Co(II), (n = 5)], detection limit [0.046 ?g L-1 Co(II)], sampling frequency [19 h-1] and reagent consumption (330 ?g of Tiron for determination) were attained. Recovery data in grass sample digests varied within 97% e 113%. Zone trapping inside the flow-through cuvette for exploiting high temperatures was also promising for relatively slow reactions, as no liberation of air bubbles was noted even for temperatures as high as 95oC. The approach was applied to the spectrophotometric determination of vanadium in mineral water samples relying on the oxidation of p-anisidine by bromate catalised by V(V) at 95ºC. Good analytical figures of merit such as repeatability [r.s.d. = 2.1% for 5.0 µg L-1 V(V), n = 10], detection limit [0.1 µg L-1 V(V), sample frequency (25 h-1) and reagent consumption (3.0 mg of p-anisidine per determination) were attained. Additionally, an analytical procedure to monitor the potentially leachable ametryn and atrazine residues in soil samples was proposed. As leaching is relatively slow, a sequential injection system was used to perform the herbicide extractions with 0.01 mol L-1 CaCl2 and in-line solid phase extraction followed by elution towards a C18 monolithic column connected to a liquid chomatograph. To this end, the outlet of the column was connected to a 300-µL six-port valve. Regarding analytical performance, enrichment factors and detection limits were 10.2 and 18.8 and 0.016 e 0.015 mg L-1 for ametryn and atrazine, respectively, quantification limits were 0.05 mg L-1 for both herbicides and good repeatability (r.s.d. = 6.3 and 5.1 % for 0.05 mg L-1 of ametryn and atrazine, n = 10) were attained. Recovery data in the soil extracts under equilibrium conditions were within 85 and 99%
156

Estudo da síntese convergente de peptídeos em fase sólida: abordagem clássica e uso de temperatura alta / Study of the convergent solid phase peptide synthesis: classical approach and use of high temperature

Ruiz, Cesar Manuel Remuzgo 12 December 2003 (has links)
A síntese de peptídeos em fase sólida passo a passo (SPFS) tem sido aplicada com sucesso na preparação de peptídeos curtos, médios e de determinados sequências contendo mais de 30 resíduos. Entretanto, esta apresenta problemas e limitações que podem ser contornados pela síntese convergente de peptídeos em fase sólida (SCPFS) que se baseia na condensação entre fragmentos peptídicos Nα-acilados protegidos em suas cadeias laterais (doadores de acila) a fragmentos protegidos ligados a um suporte polimérico (receptores de acila). Além de desenvolver outros projetos enfocados na síntese de peptídeos ou no uso de sintéticos para o estudo de peptídeos biologicamente ativos ou proteinas, o nosso grupo de pesquisa tem se dedicado a estudar o emprego de temperaturas altas em SPFS. O objetivo final é propor protocolos ágeis alternativos aos empregados classicamente. Neste trabalho nos propusemos a investigar alguns aspectos da SCPFS e a explorar a possibilidade de agilizá-Ia a 60°C. Para tanto, empregamos como modelos a colecistocinina-33 humana (hCCK-33) não sulfatada e o análogo [Gln1]-gomesina. As seqüências destes peptídeos foram divididas em: doadores de acila (fragmentos central e N-terminal da hCCK-33 não sulfatada de 11 e de 5 resíduos, respectivamente, e N-terminal de 8 resíduos do [Gln1]-gomesina) e receptores de acila (fragmentos C-terminais da hCCK-33 não sulfatada de 17 resíduos e do [Gln1]-gomesina de 10 resíduos). As peptidil-resinas correspondentes foram sintetizadas manualmente por SPFS passo a passo e caracterizadas por análise de aminoácidos para determinação de seus graus de substituição. Suas propriedades de solvatação em diferentes sistemas de solventes foram também examinadas. Análises por RP-HPLC e LC/ESI-MS dos peptídeos brutos obtidos após clivagem das resinas e desproteção total permitiram avaliar as sínteses realizadas. Os doadores de acila foram então gerados a partir das peptidil-resinas empregando procedimentos conhecidos (catálise por DBU ou NaOH) e um proposto por nós (assistência por íons metálicos). Finalmente, os acoplamentos entre os doadores e receptores de acila foram realizados a 37 e 60°C empregando sistemas de solventes adequados à solvatação dos receptores de acila e diferentes reagentes acopladores. As peptidil-resinas alongadas foram analisadas em seu conteúdo de aminoácidos e submetidas à clivagem e desproteção total para liberação dos peptídeos brutos correspondentes. Estes foram submetidos à análise comparativa usando RP-HPLC e LC/ESI-MS. Os resultados obtidos neste primeiro trabalho que emprega alta temperatura na SCPFS demonstraram que: 1) o conhecimento do grau de solvatação das peptidil-resinas auxilia na escolha do sistema de solventes a ser empregado na geração dos doadores de acila (desligamento dos peptídeos protegidos correspondentes) e nos seus acoplamentos aos receptores de acila; 2) a geração de doadores de acila a partir de peptidil-KOR não é trivial como sugere a literatura (o fragmerto 6-19 da hCCK-33 na forma protegida não foi obtido) e deve ser melhor estudada. O tamanho e a seqüência peptídica parecem estar diretamente relacionados à eficiência do processo; 3) o uso de alta temperatura agiliza o processo; 4) a geração de doadores de acila a partir de peptidil-2-CI-Trt empregando 1%TFA em DCM e misturas AcOH:TFE:DCM é simples e eficiente; 5) o uso combinado de DMF, do agente acoplador TBTU e de 60°C levou à agilização dos acoplamentos convergentes realizados, fornecendo os peptídeos desejados com boa qualidade em tempos relativamente menores; 6) vantagens e desvantagens da SCPFS em alta temperatura devem ser melhor avaliadas; 7) a SCPFS também apresenta limitações e problemas a serem contornados, o que demanda exploração sistemática empregando seqüências peptídicas e resinas variadas. / Stepwise solid-phase peptide synthesis (SSPPS) has been applied successfully for the preparation of most peptides containing up to 30 residues. However, it presents problems and limitations. Convergent soIid-phase peptide synthesis (CSPPS) can overcome part of them. This methodology is based on the synthesis of peptide segments by SSPPS followed by their condensations: the Nα- acylated protected segments act as acyl donors and the protected segments bound to the resin as acyl receptors. When the sequence is completed this is detached from the resin and fully deprotected to give the crude peptide. Besides developing other projectsfocused on peptide synthesis itself or on the use of synthetics to study biologically active peptides or proteins, we have systematically examined solid-phase peptide synthesis at elevated temperature. The aim of the present work was to investigate different aspects of convergent solid-phase peptide synthesis and examine the possibility to improve it at 60°C. Thus, unsulfated human cholecystokinin-33 and [Gln1]-gomesin were divided in three and two fragments, respectively. In the first case, the acyl donors were built-up by SSPPS on Kaiser oxime resin while in the second peptide elongation was done on 2-CI-Trt resin. The acyl receptor was synthesized and kept on the MBHA resin. The synthetic process was evaluated through characterization of every peptidyl-resin by amino acid analysis and of each crude peptide obtained from resin cleavage/full deprotection by RP-HPLC and LC/ESI-MS. The swelling degrees of the peptidyl-resins were determined in various solvents or mixtures of high boiling points. The peptidyl-KOR and peptidyl-2-CI-Trt were then submitted to peptide detachment under a few experimental conditions in order to release the Nα-acyl protected peptides (the acyl donors). Finally, their couplings with the acyl receptors were carried-out at 37 and 60°C in solvents or mixtures suitable for peptidyl-resin solvation containing specific coupling agents. The resulting peptidyl-resins were isolated, dried and submitted to HF treatment to release the corresponding unprotected crude peptides, which were analysed by RP-HPLC and LC/ESI-MS. The results found indicated that: 1) the knowledge of the swelling properties of the peptidyl-resins in different solvents systems is very useful in SCPFS. Indeed, it may guide the selection of experimental conditions to be used in peptide detachment from KOR and 2-CI-Trt and in segment condensation at elevated temperature, 2) peptide detachment from KOR is not as trivial as described (it was impossible to release hCCK-33 fragment 6-19 in its protected form). Further studies are certainly required to improve it. It seems that the size and the sequence are strictly related to the process efficiency, 3) high temperature can improve it, 4) peptide detachment from 2-CI-Trt is as simple as described, 5) combination of DMF as solvent, TBTU as coupling agent and 60°C was suited for the segment couplings studied: the reactions were completed in relatively short times and crude peptides of good quality were obtained, 6) this is the first attempt to carry-out CSPFS at elevated temperature, thus its advantages and disadvantages must be studied, 7) CSPPS also presents problems and limitations to overcome. Such task requires further investigation using various resins and peptide sequences.
157

Determinação de íons metálicos por FI-FAAS após separação e concentração em fase sólida: avaliação crítica de adsorventes / Determination of metallic ions by FI-FAAS after separation and preconcentration in solid-phase: critical evaluation of adsorbents

Anaia, Grazielle de Campos 29 February 2008 (has links)
Um procedimento de separação e pré-concentração em sistemas de análises em fluxo acoplado a espectrometria de absorção atômica com atomização em chama (FI-FAAS) é proposto para a determinação de Cu(II), Ni(II) e Cd(II). Diferentes adsorventes (XAD-7, sílica-gel e sílica funcionalizada C18) foram avaliados para a imobilização do reagente 1-(2-tiazolilazo)-2-naftol (TAN) que forma complexos com diversos íons metálicos. A avaliação e seleção do adsorvente baseou-se em isotermas de adsorção (Langmuir, Freundlich e Dubinin- Radushkevich (D-R)) e estudos de dessorção. O modelo de Langmuir indicou que a -2 -1 sílica-gel adsorve uma quantidade maior de TAN (1,81±0,08)x10-2 g g-1 em relação à XAD-7 (4,05±0,51)x10-3 g g-1 e à sílica funcionalizada C18 1,58x10-2 g g-1 . Pelo modelo de Freundlich, foi verificado que a superfície da XAD-7 apresenta elevada heterogeneidade energética dos sítios de adsorção evidenciado pelo parâmetro n de 2,57±0,08 contra 1,01±0,02 para sílica-gel. A constante de Freundlich foi de -1 (0,232±0,023) e (2,27±0,59) g g-1 para XAD-7 e sílica-gel, respectivamente. O modelo de D-R revelou que ocorre fisissorção para ambos os adsorventes. Estudos de dessorção permitiram concluir que a XAD-7 modificada apresentou a menor massa de TAN dessorvida em comparação com a sílica-gel, nas condições de acidez a serem empregadas nas etapas de retenção e eluição dos íons metálicos. Desta forma, XAD-7 imobilizada com o TAN foi selecionada para pré-concentração dos metais no sistema de análises em fluxo. Utilizando um amostrador temporizado eletronicamente, as variáveis vazão e concentração do eluente, pH de retenção, vazão e tempo de pré-concentração da amostra foram avaliadas. Na etapa de amostragem, os íons metálicos foram pré-concentrados por 300 s na forma de complexos com o TAN, empregando vazão de amostra de 6,2 mL min-1 e pH 7,5. A eluição foi efetuada com 0,2 mol L-1 HNO3 e vazão de 6,2 mL min-1 . O limite de detecção e o fator de enriquecimento foram estimados em 0,20 µg L-1 e 68; 1,5 µg L-1 e 15 e 0,060 µg L-1 e 44 para Cu(II), Ni(II) e Cd(II), respectivamente. Os coeficientes de variação foram estimados em 3,2%, 5,6% e 3,6% para Cu(II), Ni(II) e Cd(II), respectivamente. O procedimento proposto para FI não é adequado para a pré-concentração de metais em amostras contendo altas concentrações de íons cloreto, devido à formação de cloro-complexos, que prejudicam a formação de complexos com TAN na fase sólida. / A flow-based procedure for separation and preconcentration coupled to flame atomic absorption spectrometry (FI-FAAS) is proposed for determination of Cu(II), Ni(II) e Cd(II). Different sorbents (XAD-7, silica gel and C18 bonded silica) were evaluated for the immobilization of the reagent 1-(2-thiazolylazo)-2-naphthol (TAN), which reacts with several metal ions yielding complexes. The evaluation and selection of the adsorbent was based on adsorption isotherms (Langmuir, Freundlich and Dubinin-Radushkevich (D-R)) as well as desorption studies. The Langmuir model indicated that silica gel uptakes higher amount of TAN (1.81±0.08)x10-2 g g-1 as compared to (4.05±0.51)x10-3 g g-1 for XAD-7 and (1.58x10-2 ) g g-1 for C18 bonded silica. Based on the Freundlich model, it was verified that XAD-7 surface presented high energetic heterogeneity of the adsorption sites evidenced by the parameter n of 2.57±0.08 against 1.01±0.02 to silica gel. The Freundlich constant was 0.232±0.023 -1 and 2.27±0.59 g g-1 for XAD-7 and silica gel, respectively. The D-R model revealed that physical sorption occurred for both adsorbents. The modified XAD-7 showed the lowest desorbed mass in comparison to silica gel, in the same acidity conditions employed for retention and eluting steps of the metal ions. XAD-7 modified with TAN was thus selected to concentrate metal ions in the flow system. Using a time-based sample loading, the variables like eluent flow rate and concentration; pH in the retention step, sample flow rate and loading sample time were investigated. In the sampling step, the metal ions were preconcentrated for 300 s in the form of TAN complexes, employing a sample flow rate of 6.2 mL min-1 and pH 7.5. The elution was carried out with 0.2 mol L-1 HNO3 and flow rate of 6.2 mL min-1 . The detection limits and enrichment factors were estimated as 0.2 µg L-1 and 68; 1.5 µg L-1 and 15 and 0.060 µg L-1 and 44 for Cu(II), Ni(II) and Cd(II), respectively. The coefficients of variation were estimated as 3.2%, 5.6% and 3.6% for Cu(II), Ni(II) and Cd(II), respectively. The proposed procedure is not appropriate for the preconcentration of metals in samples containing high chlorides concentrations due to the formation of chloride-complexes that hinder the formation of the TAN-complexes on the solid phase.
158

Avaliação da exposição de crianças a substâncias psicoativas durante a lactação através da análise toxicológica em leite materno / Evaluation of infant exposure to psychoactive substances during lactation by toxicological analysis in breast milk.

Silveira, Gabriela de Oliveira 13 June 2016 (has links)
O aleitamento materno está associado a benefícios de ordem nutricional, imunológica, afetiva, econômica e social. Grande parte das drogas lícitas e ilícitas consumidas pela lactante pode ser transferida para o leite, o que pode representar potenciais efeitos nocivos para a criança em curto e longo prazos. Embora o conhecimento a respeito de substâncias psicoativas durante a lactação venha sendo ampliado, ainda há poucas informações sobre as concentrações de substâncias excretadas por essa via e muitas dúvidas sobre os efeitos delas em crianças durante o período de amamentação. O leite materno é uma matriz não convencional que pode ser usada para avaliar a exposição de crianças a substâncias durante o aleitamento e sua principal vantagem é a coleta simples e não-invasiva. Contudo, a extração destas a partir do leite materno é um desafio analítico devido ao seu alto conteúdo lipídico e proteico, bem como a alteração na sua composição durante o período pós-parto. No presente trabalho, técnicas analíticas miniaturizadas foram desenvolvidas visando a detecção das substâncias psicoativas cocaína, cocaetileno, norcocaína, tetraidrocanabinol, canabinol, canabidiol em amostras de leite materno, utilizando cromatografia gasosa acoplada à espectrometria de massas (GC-MS). A microextração em fase líquida (LPME) foi aplicada para analitos de cocaína e a microextração em fase sólida (SPME) para canabinoides. Após o desenvolvimento e validação dos métodos, as análises foram aplicadas em amostras de leite coletadas no hospital municipal Dr. Arthur Ribeiro de Saboya (n=109). Além das técnicas terem se mostrado adequadas à extração e detecção dos analitos, confirmou-se a excreção de cocaína no leite materno em quantidades moderadas com resultado positivo para uma amostra (138 ng/mL). Bem como foi detectado tetraidrocanabinol nas concentrações de 20 ng/mL e 31 ng/mL em amostras de leite humano. / Maternal breastfeeding is related with nutritional, immunological, affective, economic, and social benefits. Most licit and illicit substances consumed by the nursing mother might be excreted in breast milk, which may cause potential harmful effects to the breastfed infant at short and long terms. Although the knowledge about the psychoactive substances during lactation is increasing, there is still few information on the levels in which these substances are excreted in breast milk and many questions about the possible effects of these substances in the infant during the nursing period still remain unanswered. Breast milk is an unconventional matrix that can be used to assess infant exposure to drugs, and its main advantage is its easy and non-invasive collection. However, the extraction of substances from breast milk is an analytical challenge because of its high protein and fat content and changing composition during the postpartum period. In this study, miniaturized analytical techniques will be carried out to determine psychoactive substances such as cocaine, cocaethylene, norcocaine, tetrahydrocannabinol, cannabinol, and cannabidiol in milk samples by using gas chromatography-mass spectrometry (GC-MS). Liquid-phase microextraction (LPME) was applied to cocaine analytes and solid-phase microextraction (SPME) was applied to cannabinoids. After the development and validation, the methods were applied in milk samples collected from municipal hospital Dr. Arthur Ribeiro de Saboya (n=109). These techniques have proved to be suitable for analyte extraction and detection. Cocaine excretion in breast milk has been confirmed given that one sample was positive to cocaine in moderate amounts (138 ng/mL), as well as, two samples could be confirmed positive to tetrahydrocannabinol at 20 ng/mL and 31 ng/mL.
159

Desenvolvimento de métodos de extração e determinação de bifenilas policloradas por cromatografia gasosa e detector de captura de elétrons em óleo Ascarel, reator anaeróbio e solo / Development and validation of a method for determination of Polychlorinated Biphenyls (PCBs) of a standard solution PCB Congener MIX 1 by gas chromatography and electron capture detector in three different matrices: Askarel oil, samples from batch anaerobic reactors and soil

Maria Angela Tallarico Adorno 23 August 2013 (has links)
Bifenilas policloradas (PCBs) são componentes de óleo ascarel, usado extensamente (no Brasil até os anos 80) como isolante em transformadores de energia devido às suas propriedades físico-químicas como estabilidade térmica e alta constante dielétrica. Apesar de ter sido proibido em todo o mundo devido à alta toxicidade dos PCBs presentes em sua composição, ainda resta grande quantidade de ascarel em circulação como resíduo \"passivo\" e resultante de contaminação em trocas dos fluidos dos transformadores, além de vazamentos. A principal forma de eliminação é por incineração, que, além de ser um processo caro, pode provocar a formação de compostos mais tóxicos, as dioxinas. Por isso é importante o monitoramento da concentração dessas substâncias, a fim de evitar maiores impactos ambientais na sua disposição, bem como em estudos de biodegradação. Esta matriz é extremamente complexa, o que torna a extração e determinação desses analitos um processo trabalhoso e difícil. Neste trabalho avaliaram-se métodos de extração e determinação de PCBs presentes na solução padrão comercial PCB Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). O desenvolvimento de métodos de extração (cromatografia em coluna, extração líquido-líquido (L-L), extração em fase sólida (SPE) e micro-extração em fase sólida - SPME) dos PCBs foi seguido da determinação, por cromatografia gasosa com detector por captura de elétrons (CG/DCE), em três matrizes diferentes: óleo ascarel, amostras provenientes de reatores anaeróbios em batelada e solo. Os métodos cuja purificação e extração diminuíram o efeito dos interferentes da matriz, como SPE - Sulfoxide, cromatografia em coluna de sílica e extração L-L com n-hexano foram validados pela avaliação dos seguintes parâmetros: linearidade e faixa de aplicação; precisão instrumental; limite de detecção, limite de quantificação e recuperação absoluta. O critério de escolha entre os métodos para extração dos PCBs do óleo que forneceram maior eficiência (cartucho SPE Sulfoxide e coluna de sílica gel, após lavagem ácida; método da adição de padrão, entre 1,0 e 4,0 mg L-1) deve considerar a disponibilidade de recursos, pois a sílica gel é mais viável economicamente do que o cartucho SPE. Os valores de R2 > 0,99 para o método de extração com sílica, mesmo tendo sido considerados apenas três pontos para a curva de calibração, atestam maior linearidade do que o método com SPE Sulfoxide (R2 entre 0,97 e 0,99). A extração L-L e determinação por CG/DCE dos PCBs (padronização interna) de amostras provenientes de reatores anaeróbios em batelada (aquosas, em matriz extremamente complexa com biomassa e espuma de poliuretano para imobilização de microrganismos) foram eficientes na faixa de concentração entre 0,05 e 0,5 mg L-1. Esse método foi adequado para monitorar PCBs em estudo de degradação anaeróbia e teste de adsorção dos PCBs em espuma; forneceu linearidade com R2 entre 0,93 e 0,96 e limites de detecção de 0,048 a 0,298 mg L-1, além de recuperação absoluta entre 14,1% e 110,7%. As condições testadas por SPME não permitiram a extração dos PCBs de óleo e de solo, principalmente devido à dessorção incompleta dos PCBs da fibra de polidimetil-siloxano, de 100 μm. / Polychlorinated biphenyls (PCBs) are components of ascarel, oil widely used as insulation (until the \'80s in Brazil) due to its physicochemical properties such as thermal stability and high dielectric constant. Despite having been banned worldwide due to the high toxicity of PCBs present in its composition, there are still lots of outstanding ascarel as \"passive\" residue and resulting contamination of fluids in transformers exchanges, plus leaks. The main form of disposal is incineration, which, besides being costly, can cause the formation of more toxic compounds, that is, dioxins. It is therefore important to monitor the concentration of these substances in order to prevent further environmental impacts in their disposal, as well as in studies of biodegradation. This is an extremely complex matrix, which makes the extraction and determination of this analytes very difficult and labor intensive. In this work we have evaluated methods of extraction and determination of the PCBs present in the standard solution Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). The extraction and cleanup developed methods which reduced the effects of interfering matrix as solid phase extraction (SPE) - Sulfoxide, column chromatography on silica and liquid-liquid (L-L) extraction with n-hexane, and solid phase microextraction (SPME) after determination of the PCBs by gas chromatography with electron capture detector (GC/ECD) were validated by assessing the following parameters: linearity and range of application; instrumental precision; detection limit; limit of quantification and absolute recovery. The criterion for choosing between the methods for extraction of PCBs from the oil with a higher efficiency (SPE cartridge Sulfoxide and silica gel column, after acid washing; using the standard addition method, between 1.0 and 4.0 mg L-1) must evaluate the availability resources, since the silica gel is more economically viable than the SPE cartridge. The R2 values > 0.99 for silica extraction method, even though it was considered only three points for the calibration curve, attested higher linearity than the method with SPE Sulfoxide (R2 between 0.97 and 0.99). The L-L extraction and determination by GC/ECD of the PCBs (internal standardization) of samples from batch anaerobic reactors (aqueous, in a very complex matrix with biomass and polyurethane foam for the immobilization of microorganisms) were efficient in the concentration range between 0.05 and 0.5 mg L-1. This method was suitable to monitor PCBs in anaerobic degradation studies and its adsorption on foam; provided R2 linearity between 0.93 and 0.96 and detection limits from 0.048 to 0.298 mg L-1, as well as absolute recovery between 14.1% and 110.7%. The conditions tested for SPME technique did not allow the extraction of the PCBs from the oil and soil, mainly due to the \"incomplete dessorption\" of PCBs from the polydimethylsiloxane fiber of 100 micron.
160

Aplicação da cromatografia a gás associada à espectrometria de massas em tandem no diagnóstico da deficiência de 3β-hidroxidesidrogenase / Application of gas chromatography coupled to tandem mass spectrometry in the diagnosis of 3β-hidroxidesidrogenase deficiency

Presutti, Thais Rodrigues 10 April 2017 (has links)
Pregnenolona (PREG) e 17-alfa-hidroxipregnenolona (17OHPREG) são dois esteroides produzidos pela glândula adrenal e precursores de vários hormônios esteroidais. A dosagem desses compostos tem aplicações clínicas, como o diagnóstico de doenças relacionadas aos corticoesteroides e mineralocorticóides e especialmente na avaliação da atividade da enzima 3-β-hidroxidesidrogenase que é decisiva no diagnóstico de um dos tipos de hiperplasia da glândula adrenal que causa defeitos severos na síntese de esteroides. Métodos cromatográficos associados à espectrometria de massas superaram a especificidade reduzida dos imunoensaios e tem sido crescentemente utilizados na quantificação de esteroides. Os últimos anos tem sido marcados pela hegemonia da cromatografia líquida acoplada à espectrometria de massas em tandem (LC-MS/MS) em grande parte devido à velocidade e possibilidade da análise direta de vários analitos. Porém, no caso específico dos esteroides de tipo 3-hidroxi-5-eno, que apresentam baixa afinidade protônica e, portanto, baixa eficiência de ionização, são necessárias muitas etapas para a conversão em derivados mais detectáveis. Embora desfavorecida em relação ao LC-MS/MS nos últimos anos, a cromatografia gasosa acoplada à espectrometria de massas (CG-MS) apresenta várias características favoráveis para a análise de esteroides como a eficiência cromatográfica ainda insuperável. Adicionalmente, a incorporação da espectrometria de massas em tandem ao CG (CG-MS/MS) torna a técnica tão seletiva quanto LC-MS/MS. No presente trabalho, foi desenvolvido um novo método que permite a extração e derivatização simultâneas da PREG e 17OHPREG de amostras de soro tornando o método de preparo da amostra tão simples quanto os descritos para LC-MS/MS. O método de detecção desenvolvido baseado em ionização química no modo negativo obteve a sensibilidade necessária para o diagnóstico da deficiência da enzima 3-beta-hidroxidesidrogenase utilizando apenas 250 &#181:L de amostra. / Pregnenolone (PREG) and 17α-hydroxypregnenolone (17OHPREG) are two steroid precursors produced by the adrenal gland. The quantification of these compounds is essential for the evaluation of 3-β-hidroxidesidrogenase enzyme activity, which promotes the conversion of PREG in 17OHPREG. The 3-&#946:-hidroxidesidrogenase deficiency is a rare but severe type of adrenal hyperplasia that causes serious defects in steroid synthesis. Chromatographic methods coupled to mass spectrometry overcame immunoassays limitations such as reduced specificity, and have been widely used for steroids quantification. Recent years have been marked by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) hegemony due to the speed and possibility to analyze directly several analytes. However, in the case of type 3-hydroxy-5-ene steroids, which have low affinity for protons and, therefore, low ionization efficiency, many steps are required for conversion to detectable products. Notwithstanding, gas chromatography coupled to mass spectrometry (GC-MS) has some favorable features for steroid analysis such as unbeatable chromatographic efficiency. In addition, the incorporation of tandem mass spectrometry (GC-MS/MS) makes it as selective as LC-MS/MS. In this study, a new method for simultaneous extraction and derivatization of PREG and 17OHPREG from serum was developed. This procedure makes sample preparation for GC-MS/MS as simples as those described for LC-MS/MS. The detection method based on negative mode chemical ionization achieved the sensitivity required for the diagnosis of 3-β-hidroxidesidrogenase defficiency using only 250 µL of sample.

Page generated in 0.0655 seconds