• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 183
  • 5
  • 4
  • 2
  • 2
  • Tagged with
  • 198
  • 198
  • 183
  • 117
  • 112
  • 101
  • 74
  • 73
  • 67
  • 50
  • 39
  • 38
  • 35
  • 32
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Desenvolvimento de uma metodologia para determinação de Pb2+ em matrizes aquosas utilizando nanopartículas magnéticas / Development of a methodology for determination of Pb2+ in aqueous matrices using magnetic nanoparticles

Silva, Carolina Aparecida de Sousa 20 April 2018 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2018-05-10T17:06:11Z No. of bitstreams: 2 Dissertação - Carolina Aparecida de Sousa Silva - 2018.pdf: 2891797 bytes, checksum: c1079049ce0d92f7213a7f8f71e94f4a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-05-10T18:11:50Z (GMT) No. of bitstreams: 2 Dissertação - Carolina Aparecida de Sousa Silva - 2018.pdf: 2891797 bytes, checksum: c1079049ce0d92f7213a7f8f71e94f4a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-10T18:11:50Z (GMT). No. of bitstreams: 2 Dissertação - Carolina Aparecida de Sousa Silva - 2018.pdf: 2891797 bytes, checksum: c1079049ce0d92f7213a7f8f71e94f4a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-04-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The iron oxide (Fe3O4) nanoparticles are promising adsorbents and, in this work, they were synthesized, characterized and applied as adsorbents in the adsorption of lead ions (Pb2+) using solid phase magnetic extraction (MSPE). The iron oxide was synthesized by the coprecipitation method and the obtained nanoparticles presented the crystalline phase of the oxide, being proved by the characterization by X-Ray Diffraction, X-ray Dispersive Energy and Absorption Spectroscopy in the Infrared region. In order to obtain information on the surface charge of the synthesized material, the pH at the zero loading point (pHPCZ) was determined indicating that the oxide surface is negatively charged at pH values above 9.4. Once the best pH (9.0) for adsorption was defined, the influence of the variables agitation time and mass of the adsorbent were evaluated, fixing them in 4 min and 3.0 mg respectively, in order to obtain the best conditions of the adsorption. adsorption process. The maximum adsorption capacity was obtained by the construction of adsorption isotherms, and a value of 31.60 mg.g1 was found. Through the kinetic study, it was observed that the adsorption obeys a pseudo-first-order kinetics. After the adsorption was optimized, the best desorption parameters were evaluated, aiming the development of an extraction/preconcentration method. Thus, 500μL of 0.5 mol.L-1 nitric acid was used as the eluent. The analytical performance was evaluated by means of the parameters, limit of detection (L.D.), limit of quantification (L.Q.), precision (D.P.R) and values found were 5.44 μg.L-1 ; 16.48 μg.L-1 and 0.25%, respectively, with the linear range of the method being 16.48 -500 μg.L-1 . Finally, the accuracy of the method was evaluated from recovery tests on samples of mineral water, micellar water and facial makeup with recovery values in the range of 95.94 - 118%. In addition, analyzes of certified water reference material (APS-1071) were also made to verify the accuracy of the proposed method. / As nanopartículas de óxido de ferro (Fe3O4) são adsorventes promissores e, neste trabalho foram sintetizadas, caracterizadas e aplicadas como adsorvente na adsorção de íons chumbo (Pb2+) utilizando extração magnética em fase sólida (MSPE). O óxido de ferro foi sintetizado pelo método de coprecipitação e as nanopartículas obtidas apresentaram a fase cristalina do óxido, sendo comprovado através da caracterização por Difração de Raio X, Energia Dispersiva de Raio X e Espectroscopia de Absorção na região do Infravermelho. A fim de se obter informações sobre a carga superficial do material sintetizado, o pH no ponto de carga zero (pHPCZ) foi determinado indicando que a superfície do óxido se encontra carregada negativamente em valores de pH acima de 9,4. Uma vez definido o melhor pH (9,0) para adsorção, a influência das variáveis tempo de agitação e massa do adsorvente foram avaliadas, fixando-as em 4 min e 3,0 mg respectivamente, a fim de se obter as melhores condições do processo de adsorção. A capacidade de adsorção máxima foi obtida pela construção de isotermas de adsorção, tendo sido encontrado um valor de 31,60 mg.g-1 . Através do estudo cinético, observou-se que a adsorção obedece uma cinética de pseudo-primeira-ordem. Após ter a adsorção otimizada, foram avaliados os melhores parâmetros para dessorção, visando o desenvolvimento de um método de extração/pré-concentração. Assim, 500µL de ácido nítrico 0,5 mol.L-1 foram utilizados como eluente. O desempenho analítico foi avaliado por meio dos parâmetros, limite de detecção (L.D.), limite de quantificação (L.Q.), precisão (D.P.R) e os valores encontrados foram 5,44 μg.L-1 ; 16,48 μg.L-1 e 0,25%, respectivamente, sendo a faixa linear do método igual a 16,48 –500 μg.L-1 . Por fim, a exatidão do método foi avaliada a partir de testes de recuperação em amostras de água mineral, água micelar e demaquilante facial com valores de recuperação na faixa de 95,94 – 118%. Além disso, análises de material certificado de referência de água (APS-1071) também foram feitas para constatar a exatidão do método proposto.
132

Isoflurano : desenvolvimento de um método analítico empregando microextração em fase sólida, incorporação em nanoemulsões e avaliação biológica das nanoemulsões

Krahn, Carolina Lopes January 2010 (has links)
O objetivo do presente trabalho foi desenvolver e validar um método analítico empregando microextração em fase sólida (SPME) para detecção e quantificação de isoflurano (ISO) na forma volátil e incluso em nanoemulsões intravenosas e, ainda, avaliar o efeito biológico destas. A detecção do ISO foi realizada através de cromatografia em fase gasosa com detector de ionização de chama (CG/DIC). As condições ideais para realização da pré-concentração e extração de ISO através da técnica de SPME foram temperatura ambiente, agitação constante, 30 min de extração e 2 min de dessorção no injetor do CG. O método desenvolvido foi validado avaliando os parâmetros de especificidade, linearidade, limites de detecção e quantificação, precisão, exatidão e robustez. As nanoemulsões contendo ISO foram desenvolvidas através da homogeneização à alta pressão, e apresentaram diâmetro médio, índice de polidispersão, potencial zeta e pH de 150 ± 0,78 nm, 0,08 ± 0,01, - 18 ± 2,4 mV e 6,03 ± 0,04, respectivamente. O pH foi ajustado para 7,4 (valor fisiológico). O teor de ISO nas formulações foi de 98,4 %. Não houve modificação das características físico-químicas das nanoemulsões após 30 dias de armazenamento a 8 ºC. Análises de espalhamento de luz múltiplo não demonstraram tendência a fenômenos de instabilidade física para as formulações. Os estudos do efeito anestésico das nanoemulsões intravenosas contendo ISO em cães evidenciaram uma redução significativa (p < 0,05) na dose comparada com a administração de ISO volátil. Não houve alterações no débito cardíaco, saturação de oxigênio na hemoglobina e nos biomarcadores das funções renal, hepática e muscular. Uma queda na pressão arterial dos cães foi observada em todos os tratamentos devido ao efeito hipotensor do ISO. Após administração das nanoemulsões contendo ISO e branca, observou-se taquipnéia, edema, eritema, e baixas concentrações de dióxido de carbono expiradas. Assim, a nanoemulsificação do ISO foi realizada com sucesso e a aplicação na anestesia geral intravenosa foi demonstrada. / The aims of this work were to develop and validate an analytical method using solidphase microextraction (SPME) to detect and quantify isoflurane (ISO) inhalation liquid and loaded in intravenous nanoemulsions, and also evaluate the biological effect of the formulations. ISO detection was made by gas chromatography with flame ionization detector (GC/FID). The ideal conditions setting for the pre concentration and extraction of ISO through SPME were environmental temperature, constant stirring, 30 min for extraction and 2 min for analyte desorption in the GC inlet port. The developed method was validated by means of specificity, linearity, detection and quantification limits, precision, accuracy and robustness. The ISOloaded nanoemulsions were formulated by high-pressure homogenization, and presented average diameter, polydispersity index, zeta potential and pH of 150 ± 0.78 nm, 0.08 ± 0.01, -18 ± 2.4 mV and 6.03 ± 0.04, respectively. The pH was adjusted to 7.4 (physiological value). The drug content on the formulations was 98.4 %. After 30 days of storage at 8 ºC no changes on nanoemulsion’s physicalchemical characteristics were observed. Multiple light scattering analysis did not demonstrate any physical destabilization phenomena for the formulations. The anesthetic effect study for the intravenous ISO-loaded nanoemulsions in dogs highlighted a significant reduction (p < 0.05) in dosage regimen when compared to the volatile ISO administration. There were no alterations on cardiac rate, oxygen hemoglobin saturation and on biomarkers of the renal, hepatic and muscle functionalities. A decrease in dog’s arterial blood pressure in all treatments due the hypotensive effect caused by ISO was observed. After the administration of the nanomulsions, ISO-loaded and unloaded, occurred tachypnea, edema, erythema and low end tidal concentrations of carbon dioxide. Taking all above into account, the method was considered easy on execution and suitable for laboratory routines, the ISO nanoemulsification was made successfully and its application on general anesthesia was demonstrated.
133

Síntese em fase sólida e em solução de anéis pirrolizidínicos e avaliação da atividade carrapaticida contra rhipicephalus (boophilus) microplus / Solid and solution-phase synthesis of pyrrolizidines and the evaluation of its activity against the cattle tick Rhipicephalus (Boophilus) microplus

Duarte, Mônica Oliveira January 2008 (has links)
No presente trabalho desenvolveu-se uma rota sintética em fase sólida para obter de forma rápida o esqueleto da hiacintacina 110 utilizando-se L-Boc-prolina 101 como bloco de construção. Não há relatos na literatura, até o momento, do uso da Lprolina como material de partida para a síntese de núcleos pirrolizidínicos, entretanto o estudo desta rota é uma alternativa interessante porque possibilita a síntese destes biciclos em apenas 4 etapas. A síntese iniciou com o acoplamento entre a L-Bocprolina 101 e a resina Merifield 41 em condições clássicas. Após a retirada do grupamento protetor com ácido cloridríco por 40 minutos em temperatura ambiente, procedeu-se à adição de Michael do produto 103 ao propiolato de etila 116 gerando o enaminodiéster 104. Na última etapa usou-se DBU sob irradição de microondas por 10 minutos, obtendo-se o azabiciclo 110 com redimento de 37%. Em solução, através da adição de Michael entre a L-prolina O-protegida 95 e alcinos e alceno ativados obtevese adutos cuja estereoquímica das olefinas foi sempre E, com bons rendimentos (60- 95%). Os enaminodiésteres 97 e 118 foram facilmente convertidos nos seus correspondentes aminodiésteres 124 e 126 com NaBH(OAc)3 com redimento de 65%. Na etapa da ciclização de Dieckmann obteve-se sucesso utilizando Na/THF/3h sob refluxo gerando o azabiciclo[3.3.0]octano desejado com rendimento de 50-60%. Os análogos das hiacintacinas foram sintetizados a partir da redução dos produtos 109, 132 e 133 com LiAlH4/THF e rendimentos de 52%. Os produtos 109, 132, 133, 135, 136 e 137 foram testados para atividades antiparasitárias e apresentaram bons resultados para a ação carrapaticida com doses até 0,625μg/ml em ovos e 1,25μg/ml em larvas. / We present here an original solid-phase approach to synthesize rapidly the hyacinthacine core 110 using L-proline N-Boc 101 as building block. There is no reference in the literature wich uses L-proline as building block to synthesize this pirrolizidine skeleton. The study of this possibility would be extremely interesting because it could be used to prepare structural systems related to hyacinthacine in only four steps. The synthesis initiates with the coupling of L-Boc-proline 101 to Merrifield resin 41 under classical conditions. The protection group was removed with hidrogen chloride and the Michael addition was proveeded with adduct 103 and ethyl propiolate 116, afording 104 in satisfactory yields. At least, the azabicycle 110 was obtained by reacting 98 using DBU as catalyst at MW irradiation for 10 min, in good yields (37 %). In solution, we have proceed to Michael addition of L-proline O-protected 95 to activated alkynoates/alkenes conducing to aducts where the stereochemistry of the olefins was always E, with excellent yield (60-95%). Enaminoesters 97 and 118 could be easily converted into the corresponding aminodiesters 124 and 126 by NaBH(OAc)3 in 65% yield. In the step of the Diekmann cyclization of aminodiesters the sistem Na/THF/3h at reflux afforded the derived azabicyclo[3.3.0]octanes in 50- 60% yield. The analogs of the hyacinthacines were synthesized with reduction of 109, 132 and 133 with LiAlH4/THF in 52% yield with the stereochemistry to be determined. The products 109, 132, 133, 135, 136 and 137 were tested for parasitic activity and showed good results. Compounds 109, 132, 135 and 136 killed 100% of the larvae at the concentrations of 5 μg/ml and 2.5 μg/ml being not toxic at the lower concentrations. Compounds 133 and 137 were more toxic being lethal to the larvae at concentrations of 1.25 μg/ml but did not case death at the lower concentrations.
134

Avaliação de diferentes sorventes para extração em fase sólida de pesticidas em água

Santos, Alex Sandro Magno de São José 24 September 2010 (has links)
In this work a method using solid phase extraction (SPE) and gas chromatography coupled to mass spectrometry (GC/MS) for determination of pyrimethanil, flumetralin and krexosim-methyl from water was developed. Different commercial sorvents were evaluated (C18, ENVI-Carb, Florisil, silica and ENVI-Carb/LC-NH2) at concentration level of 2.5 μg L-1 (three replicates). The best results were obtained using C18, with recovery values of 102.3, 79.0 and 89.0 % for pyrimethanil, flumetralin and kresoxim-methyl, respectively. Therefore, the validation of the method was carried out with C18 sorvent. Recovery experiments were carried out (seven replicates), at three fortification levels (0.5, 2.5 and 5.0 μg L-1), resulting in recoveries in a range of 62.6 to 104.6 % and relative standard deviations between 5.1 and 15.5 %. Detection and quantification limits ranged from 0.002 to 0.005 μg L-1 and from 0.007 to 0.147 μg L-1, respectively, for the different pesticides studied. The developed method was linear over the range assayed, 0.05-4.0 μg mL-1, with correlation coefficients above of 0.99. Next, peat was tested for solid-phase extraction of these pesticides from water. Recovery experiments were carried out (three replicates) at fortification level of 2.5 μg L-1, resulting in recoveries of 41.1, 95.9 and 88.3 % for pyrimethanil, flumetralin and kresoxim-methyl, respectively. Results have shown that the peat material can be successfully applied for analysis of flumetralin and kresoxim-methyl in water. The procedure developed was applied to the determination of these pesticides in drinking water sample. No pesticide residues, at concentrations above the limit of detection, were found in the sample. / A contaminação da água preocupa devido a sua grande importância para as formas de vida, em especial a humana, gerando a necessidade de um controle na contaminação das águas potável, de irrigação, de superfície, subterrâneas ou de efluentes industriais. Justifica-se assim a importância na determinação de resíduos de pesticidas em água. Neste trabalho foi desenvolvido e validado um método analítico utilizando a técnica de extração em fase sólida (EFS), com a avaliação da eficiência de diferentes sorventes para extração de resíduos dos pesticidas pirimetanil, flumetralina e cresoxim-metílico de água e análise por cromatografia a gás acoplada a espectrometria de massas (CG/EM). Foram avaliados os sorventes comerciais: C18, ENVI-Carb (carbono grafitinizado), Florisil, sílica e ENVI-Carb/LC-NH2 (resina polimérica do aminopropil), para o nível de fortificação de 2,5 μg L-1 em triplicata. A fase C18 apresentou os melhores valores de recuperação para pirimetanil, flumetralina e cresoxim-metílico, com os valores 102,3; 79,0 e 89,0 %, respectivamente. A validação do método foi realizada com o sorvente comercial C18. O estudo da recuperação dos pesticidas, em uma série de sete replicatas, mostrou valores de recuperação que variaram entre 62,6 e 104,6 % para os níveis de fortificação de 0,5, 2,5 e 5,0 μg L-1, com desvio padrão relativo entre 5,1 e 15,5 %, limite de detecção entre 0,002 e 0,044 μg L-1 e limite de quantificação entre 0,007 e 0,147 μg L-1. A curva analítica foi feita no extrato da matriz com os seguintes valores de concentração dos pesticidas: 0,05; 0,1; 0,2; 0,5; 1,0; 2,0; 3,0; 4,0 μg mL-1 e apresentou r acima de 0,99. Em seguida, foi avaliada a turfa como sorvente para o nível de fortificação de 2,5 μg L-1 em triplicata. Os valores de recuperação para pirimetanil, flumetralina e cresoxim-metílico foram de 41,1; 95,9 e 88,3 %, respectivamente, sendo, portanto uma alternativa viável e de baixo custo para a extração dos pesticidas flumetralina e cresoxim-metílico de água. O método foi aplicado em amostra de água potável, utilizando como sorventes C18 e turfa, sendo que não foram detectados resíduos de pesticidas considerando os limites de detecção do método.
135

Materiais inorgânicos associados a sistemas multicomutados para a determinação de espécie químicas em alimentos

LEOTERIO, Dilmo Marques da Silva 21 March 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-05-30T13:01:39Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE DILMO MARQUES_2016.pdf: 3410115 bytes, checksum: ef2c4a31a389b0d7af33d59ec444fa24 (MD5) / Made available in DSpace on 2017-05-30T13:01:39Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE DILMO MARQUES_2016.pdf: 3410115 bytes, checksum: ef2c4a31a389b0d7af33d59ec444fa24 (MD5) Previous issue date: 2016-03-21 / CNPQ / Neste trabalho foram desenvolvidos métodos analíticos, baseados no conceito de multicomutação, para análise de espécies químicas em alimentos. Para isto, foram sintetizados dois materiais: um composto de coordenação usado como fase sólida na determinação de açúcares redutores e uma rede de sílica utilizada como resina de pré-concentração de percloratos. O composto de coordenação cobre (II) - 4,4 '- bipiridina foi usado no desenvolvimento do método para a determinação de açúcares redutores em água de coco e sucos empregando sistema em fluxo multicomutado com detecção espectrofotométrica. A metodologia de análise baseou-se na reação de oxi-redução em meio alcalino entre o reagente sólido e os açúcares redutores. A reação entre a fase sólida (de coloração azul) com (glicose + frutose) resulta em produto de cor amarelada, monitorada em 420 nm. A fase sólida foi fixada em 50 mg e temperatura de 90ºC. Com volume de zona de amostragem de 160 L, que corresponde a 20 ciclos, obtendo resposta linear entre 1,0 e 20,0 g L-1 de AR com RSD de 4,47% (n = 7 ), limite de detecção de 0,2250 g L-1, limite de quantificação de 0,7496 g L-1, freqüência analítica de 75 determinções por hora e geração de efluentes de 320 μL por determinação. Os teores de açúcar redutor encontrados em sucos e água de coco variaram de 38,35 a 98,50 g L-1 e 61,80 a 68,70 g L-1 respectivamente. A rede de sílica, 2,5,8,11,14-pentaoxa-1-silaciclotetradecano, foi empregada num sistema multicomutado como coluna de pré-concentração de perclorato. O sistema foi acoplado a um detector potenciométrico para determinar percloratos em vegetais. Usou-se um eletrodo tubular com membrana constituída por 1% (m/m) de BNIP 4,4 Dapm LC1 solubilizado em 68% (m/m) de 2-nitrodifeniléter, como solvente mediador e 31% (m/m) de poli (cloreto de vinila). Obteve-se limite de detecção de 2,8x10-7 mol L-1, resposta linear no intervalo de 1,0x10-9 a 1,0x10-1 mol L-1, coeficiente de correlação linear de 0,9998 e a coluna apresentou uma capacidade de retenção de 2,86x10-3 mol de perclorato. O sistema foi aplicado às amostras de diferentes vegetais e foram encontradas concentrações de percloratos de 1,30 a 5,08 µg L-1 o teste recuperação variou de 96,5 a 110,8 %. / Two new multicommutation-based analytical methods were developed aiming to the quantification of chemical species in food. The first method is intended to the determination of reducing sugars in coconut water and fruit juices, while the second one is a potentiometric determination of perchlorates in horticultural products. The method eveloped for the determination of reducing sugars uses a multicommuted flow system with spectrophotometric detection employing a (copper (II) - 4,4’ – bipyridyl) coordination compound as the solid-phase reagent. The reaction of the solid blue phase with glucose/fructose resulted in a yellowish solution, which was monitored at 420 nm; 50 mg of the solid phase was used and the temperature was set at 90ºC. The volume of the sample zone was, 160 L, corresponding to 20 cycles, with a linear response of 1.0 e 20.0 g L-1 to the RA and RSD of 4.47% (n = 7), detection limit of 0.2250 g L-1, the limit of quantification was 0.7496 g L-1, analytical frequency of 75 determination per hour and effluent generation of 320 L per determination. The potentiometric method used to determine perchlorates used a tubular electrode formed by a polymeric membrane which showed the best features consisted of 1% (w/w) BNIP Dapm LC1 solubilized in 68% (w/w) of 2-nitrodiphenyl ether as a mediator solvent and 31% (w/w) poly(vinyl chloride) as the polymeric matrix. A limit of detection of 2.8x10-7 mol L-1 was obtained with a linear response in the range of 1.0x10-9 at 1.0x10-1 mol L-1, linear correlation coefficient of 0.9998 and the column retention capacity 2.86x10-3 mol perchlorate. Was applied to samples of different vegetables found perchlorates 1.30 to 5.08 µg L-1 and recovery between 96.5 and 110.8%.
136

Projeto e avaliação de um modulador criogenico para cromatografia gasosa bidimensional abrangente (GC x GC) / Development and evaluation of a cryogenic modulator for comprehensive two-dimensional gas chromatography (GC X GC)

Pedroso, Marcio Pozzobon 15 August 2018 (has links)
Orientador: Fabio Augusto / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-15T02:24:41Z (GMT). No. of bitstreams: 1 Pedroso_MarcioPozzobon_D.pdf: 8593602 bytes, checksum: ef9b8a25b7ff1f1f8fdec875ceb02e0f (MD5) Previous issue date: 2009 / Resumo: O objetivo do trabalho foi projetar e avaliar um modulador criogênico para cromatografia gasosa bidimensional abrangente (GC×GC). O modulador projetado foi baseado no modulador de quatro jatos (dois jatos quentes e dois jatos frios); N2 (g) resfriado em N2 (l) foi utilizado como fluido criogênico e N2 (g) aquecido foi utilizado como gás quente. O modulador foi instalado em um cromatógrafo a gás com detector por ionização em chama (GC-FID). O controle das válvulas solenóides e a digitalização do sinal analógico do FID foram realizados por software escrito em ambiente LabVIEW. Os resultados obtidos com o protótipo GC×GC-FID foram comparados com dados obtidos em um GC×GC-FID comercial. O desempenho de ambos os sistemas pode ser considerado equivalente, levando em consideração eficiência cromatográfica e repetibilidade. O protótipo GC×GC-FID foi empregado na análise de diversas amostras, em especial a fração volátil de polpa de abacaxi fresco e desidratado. Os voláteis foram extraídos por microextração em fase sólida através da extração dinâmica do headspace (DHS-SPME). A identificação dos compostos foi feita por cromatografia gasosa acoplada a espectrometria de massas (GC-MS) e avaliação dos índices de retenção. A identificação dos picos no cromatograma GC×GC foi feita através da comparação dos índices de retenção e dos perfis cromatográficos previamente obtidos por GC-MS. Como esperado, a análise por GC×GC-FID apresentou maior detectabilidade e poder de separação quando comparada com GC-FID. Por fim, alguns compostos não identificados por GC-MS foram identificados através de informação obtida pela estruturação cromatográfica da GC×GC. / Abstract: The aim of this project was to develop and evaluate a cryogenic modulator for comprehensive two-dimensional gas chromatography (GC×GC). The design of the modulator was based on a cryogenic quad jet modulator; N2 (g) cooled with N2 (l) was used as the cryogenic fluid and heated N2 (g) was used as the hot gas. The modulator was fitted into a gas chromatograph equipped with a flame ionization detector (GC-FID). The control of the solenoid valves and digitalization of the analogic FID signal were performed by software written in the LabVIEW platform. Results obtained with the GC×GC-FID prototype were compared with data from a commercial GC×GC-FID system. The performance of both systems was similar regarding chromatographic efficiency and repeatibility. The GC×GC-FID was employed for analysis of several samples, specially volatile organic compounds of fresh and dried pineapple pulp. The analytes were isolated by dynamic headspace solid phase microextraction (D-HSSPME); identification of the compounds was performed by conventional gas chromatography coupled to mass spectrometry (GC-MS) and evaluation of retention indexes. The identification of the peaks on the GC×GC chromatograms was carried out by comparison of retention indexes and chromatographic profiles previously obtained by GC-MS. As expected, the detectivity and separation power of the GC×GC-FID analysis was significantly better than that of GC-FID. Moreover, the identity of some compounds not identified by GC-MS was assigned after information obtained from GC×GC chromatographic structure. / Doutorado / Quimica Analitica / Doutor em Ciências
137

Citometria de fase sólida aplicada ao teste de esterilidade do produto Cloreto de Sódio 0,9% Solução Injetável / Solid-Phase Cytometry applied to sterility test for Sodium chloride 0.9% Injectable Solution Product

Silva, Gisele Badauy Lauria 22 June 2015 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2017-05-05T18:49:22Z No. of bitstreams: 2 Dissertação - Gisele Badauy Lauria Silva - 2015.pdf: 2934917 bytes, checksum: 7660d0a89305d09f8d7a2fe77bda401e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-05-10T13:35:58Z (GMT) No. of bitstreams: 2 Dissertação - Gisele Badauy Lauria Silva - 2015.pdf: 2934917 bytes, checksum: 7660d0a89305d09f8d7a2fe77bda401e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-05-10T13:35:59Z (GMT). No. of bitstreams: 2 Dissertação - Gisele Badauy Lauria Silva - 2015.pdf: 2934917 bytes, checksum: 7660d0a89305d09f8d7a2fe77bda401e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2015-06-22 / The sterility test is a test that certificate the absence of viable microorganisms in pharmaceutical raw materials, drugs and medical device. The Solid Phase Cytometry method (SFC) is based on the detection of viable cells through the use of viability markers reagents, that permeate the cell membrane and are cleaved by nonspecific esterase enzymes, forming the fluorochromes that are detected by ChemScan RDI® equipment. It is a fast and innovative method for the sterile injecting drugs area. The objective of the study was to evaluate and validate this technology applied to the sterility test, of the product Sodium Chloride (NaCl) 0.9% Injectable Solution, using the ChemScan RDI® equipment (CS RDI®). Eight microorganisms were evaluated, being six compendial (Clostridium sporogenes NCTC 12935 (ATCC 11437), Pseudomonas aeruginosa NCTC 12924 (ATCC 9027), Staphylococcus aureus NCTC 10788 (ATCC 6538), Bacillus subtilis NCTC 10400 (ATCC 6633), Aspergillus brasiliensis NCPF 2275 (ATCC 16404) and Candida albicans NCPF 3179 (ATCC 10231)) and two "in house” microorganisms, obtained from bioburden monitoring of pre sterilization (Micrococcus luteus and Staphylococcus epidermidis). The Solid Phase Cytometry methodology through logistic regression statistical analysis and Chi-square test, showed to be more rapid than the sterility test by membrane filtration (MF) for all tested microorganisms, reducing the analysis time from 14 days to about 3 hours. The method was validated by the use of qualitative parameters: specificity, limit of detection and robustness. / O teste de esterilidade é um ensaio que certifica a ausência de micro-organismos viáveis em insumos farmacêuticos, medicamentos e produtos para saúde. A Citometria de Fase Sólida (CFS) é um método rápido e inovador para a área de medicamentos estéreis injetáveis e é fundamentado na detecção de células viáveis através da utilização de reagentes marcadores de viabilidade, que permeiam a membrana celular e são clivados por enzimas esterases não específicas, formando o fluorocromo, que são detectados pelo equipamento ChemScan RDI®. O objetivo do estudo foi avaliar e validar esta tecnologia aplicada para o teste de esterilidade, no produto Cloreto de Sódio (NaCl) 0,9% Solução Injetável, utilizando o equipamento ChemScan RDI® (CS RDI®). Os micro-organismos padrões utilizados para os testes foram Clostridium sporogenes NCTC 12935 (ATCC 11437), Pseudomonas aeruginosa NCTC 12924 (ATCC 9027), Staphylococcus aureus NCTC 10788 (ATCC 6538), Bacillus subtilis NCTC 10400 (ATCC 6633), Aspergillus brasiliensis NCPF 2275 (ATCC 16404) e Candida albicans NCPF 3179 (ATCC 10231), e dois micro-organismos “in house” obtidos do monitoramento da biocarga pré esterilização, o Micrococcus luteus e Staphylococcus epidermidis. O método de Citometria de Fase Sólida mostrou-se significativamente mais rápido em relação ao teste de esterilidade por filtração em membrana (FM) para todos os micro-organismos testados, reduzindo o tempo de análise de 14 dias para aproximadamente 3 horas. O método foi validado por meio da utilização dos parâmetros qualitativos: especificidade, limite de detecção e robustez.
138

\"Otimização da extração, separação cromatográfica, identificação e quantificação de fármacos em fluidos biológicos\" / \"Optimization of the extraction, chromatographic separation, identification, and quantification of drugs in biological fluids\"

Christian Fernandes 20 December 2006 (has links)
Este trabalho apresenta o desenvolvimento de diferentes métodos para a determinação de fluoxetina, norfluoxetina e bisfosfonatos, utilizando técnicas modernas de preparo de amostras. Dentre eles, um método simples e sensível, empregando microextração em fase sólida (SPME) e cromatografia líquida foi desenvolvido para a análise de fluoxetina e norfluoxetina em plasma. As condições de SPME foram otimizadas empregando planejamento fatorial. A extração foi realizada utilizando fibras com PDMS-DVB, e a etapa de dessorção foi realizada em uma nova interface homemade com sistema de aquecimento. Extração com sorção em barra de agitação (SBSE) com derivatização in-situ, combinada com dessorção com solventes ou dessorção térmica, acoplada à cromatografia gasosa e espectrometria de massas (GC-MS), foi também empregada para a determinação de fluoxetina em plasma. Avaliou-se a derivatização dos analitos in situ com cloroformato de etila, bem como os parâmetros tempo de extração, solvente e tempo de dessorção. A combinação de SBSE e LC-MS foi também avaliada. As amostras de plasma foram submetidas à precipitação de proteínas com ácido tricloroacético, extraídas com SBSE, e analizadas por LC-MS. Os métodos SPME-LC, SBSE-GC e SBSE-LC desenvolvidos foram completamente validados, demonstrando serem adequados para analisar fluoxetina em amostras de plasma. Métodos rápidos para a determinação de etidronato, clodronato, pamidronato e alendronato, baseados em cromatografia de troca iônica com detecção indireta no ultravioleta, foram também desenvolvidos. Os métodos são simples e demonstraram precisão, exatidão e especificidade. Além disso, os métodos validados empregam colunas de sílica, mais baratas e de mais disponibilidade do que as colunas poliméricas, frequentemente utilizadas em métodos descritos na literatura para o mesmo propósito. / This study describes different methods to analyze fluoxetine, norfluoxetine and bisphosphonates, employing modern sample preparation techniques. A simple and sensitive procedure using solid-phase microextraction (SPME) coupled with liquid chromatography was developed for the analysis of fluoxetine and norfluoxetine in plasma samples. SPME conditions were optimized employing a factorial design. The sampling step was performed using a PDMS-DVB fiber and desorption was carried out in a novel homemade heated interface. Stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry (GC-MS), was employed for the analysis of fluoxetine. In situ derivatization using ethylchloroformate was evaluated as well as parameters such as solvent polarity, time for analytes desorption, and extraction time. SBSE combined with liquid chromatography and mass spectrometry was also used to analyze fluoxetine in plasma. Plasma samples were first submitted to protein precipitation with trichloroacetic acid, subjected to SBSE, and thereafter analyzed by LC-MS. SPME-LC, SBSE-GC, and SBSE-LC methods were completely validated showing to be adequate to assess fluoxetine in plasma samples. Rapid methods for etidronate, clodronate, pamidronate and alendronate assay were also developed. The methods were based on ion chromatography with indirect ultraviolet detection, which avoids the need for chemical derivatization procedures. The methods were simple, rapid, and demonstrated precision, accuracy, and specificity. Furthermore, they employed silica-based columns, cheaper and more readily available than polymeric columns, frequently used in previous reported methods.
139

\"Análise de fármacos em fluidos biológicos empregando o acoplamento SPME-LC/MS\" / \"Analysis of pharmaceutical compounds in biological fluids using on-line SPME-LC/MS\"

Claudete Alves 19 April 2006 (has links)
Os métodos convencionais para a determinação de fármacos em fluidos biológicos baseiam-se em técnicas cromatográficas e imunoquímicas. O tratamento prévio de amostras biológicas, o qual abrange as etapas de extração, pré-concentração e “clean-up”, tem sido requerido nas análises de fármacos, para aumentar a sensibilidade e seletividade analítica. No entanto, nos últimos anos, com o avanço das técnicas instrumentais, diversas técnicas têm sido avaliados para a análise de diferentes fármacos em fluidos biológicos, destacando-se entre elas a Microextração em Fase Sólida (SPME) e a Cromatografia Líquida acoplada a Espectrometria de Massas (LC/MS). A SPME apresenta uma série de vantagens em relação às técnicas de extração tradicionais, ou seja: não requer instrumentação analítica sofisticada, não utiliza solvente orgânico, permite automação das análises, a reutilização das fibras extratoras e integra em um único sistema, a extração, concentração e introdução da amostra no sistema cromatográfico. Neste trabalho, foi desenvolvida uma interface versátil e de baixo custo, que permite o acoplamento das técnicas SPME-LC/MS para análise dos fármacos antidepressivos tricíclicos e anticonvulsivantes. O planejamento fatorial empregado mostrou ser uma ferramenta estatística importante e simples, sendo obtido mais informações com um número menor de experimentos, avaliando não só os efeitos principais como os efeitos de interação de todas as variáveis nas respostas. As condições cromatográficas otimizadas foram adequadas para a análise por LC/MS. Os níveis de detecção alcançados ressaltam a importância e destaque da técnica de cromatografia líquida de alta eficiência acoplada à espectrometria de massas (LC/MS). O método desenvolvido, tanto para os fármacos antidepressivos tricíclicos como para os anticonvulsivantes, mostrou especificidade, precisão, linearidade e limite de quantificação adequado para a análise. / Conventional methods used for the determination of drugs in biological fluids are based on chromatographic and immunochemical techniques. The biological samples treatment - which includes extraction, pre-concentration and clean up steps – has been required in drugs analysis in order to increase both analytical sensitivity and selectivity. Nevertheless, lately, within the advancements in instrumentation, different techniques have been evaluated for the analysis of different drugs in biological fluids, such as: solid phase microextraction (SPME) and liquid chromatography coupled to mass spectrometry (LC/MS). SPME presents many advantages towards the conventional extraction techniques (soxhlet, LLE and SPE), which include: use of simple analytical instrumentation, analysis automation, reuse of extractor fibers and integration of extraction, concentration and sample introduction in the same chromatographic system. In this work, a versatile and low cost interface was developed, which allows the coupling of SPME-LC/MS techniques to tricyclic antidepressants and anticonvulsivant drugs analysis. The employed factorial design has shown to be a simple and useful statistical tool. With this device more information could be obtained with fewer experiments by evaluating not only the main interaction effects but also the interaction effects of all variables on the results. The optimized chromatographic conditions were adequate for LC/MS analysis. The obtained detection levels highlight the importance of high performance liquid chromatography coupled to mass spectrometry (LC/MS). The developed method, for both tricyclic antidepressants and anticonvulsivants drugs, has presented specificity, accuracy, linearity and adequate limit of detection for this analysis.
140

Desenvolvimento e validação da metodologia SPE-LC-MS/MS para a determinação de fármacos e droga de abuso nas águas da represa Guarapiranga - São Paulo/SP, Brasil / Development and validation of methodology SPE-LC-MS/MS for pharmaceuticals and illicit drug determination in the waters of Guarapiranga dam - Sao Paulo/SP, Brazil

Helena Miho Shihomatsu 18 March 2015 (has links)
Este estudo apresenta o desenvolvimento da metodologia de extração em fase sólida e separação em cromatográfica líquida acoplada a espectrometria de massas em sequencia, SPE-LC-MS/MS, para a determinação de 21 (vinte e um) fármacos pertencentes a diferentes classes terapeuticas, 1 (uma) droga de abuso e seu principal metabólito, em amostras de água superficial. A separação cromatográfica foi otimizada estudando o desempenho de fases estacionárias e fases móvies. A quantificação dos compostos selecionados foi realizada com a ionização por eletronebulização (electrospray ionization- ESI) e o espectrômetro de massas operando no modo de Monitoramento de Múltiplas Reações (Multiplas Reaction Monitoring- MRM). A validação da metodologia proposta foi realizada utilizando os parâmetros de seletividade, efeito de matriz, faixa de trabalho, linearidade, limites de detecção (LD) e quantificação (LQ), precisão, exatidão, recuperação e robustez. A validação da metodologia permitiu a sua aplicação na avaliação da distribuição dos 23 compostos selecionados, nas águas da represa Guarapiranga, um dos principais sistemas produtor de água potável da Região Metropolitana de São Paulo (RMSP). A presença desses poluentes nos ambientes aquáticos é proveniente da liberação direta do esgoto urbano das habitações do seu entorno, como consequência do precário sistema de saneamento básico. As águas da represa Guarapiranga foram avaliadas em 14 (quatorze) locais estrategicamente escolhidos e amostradas durante 3 (três) campanhas de coleta de amostra (agosto de 2011, setembro de 2012 e abril de 2013). Nessas amostras foram quantificados acetaminofeno (9,6 - 254 ng L-1), atenolol (8,5 177 ng L-1), benzoilegonina (7,9 139 ng L-1), cafeína (27 27386 ng L-1), carbamazepina (12 358 ng L-1), clortalidona (9,4 35 ng L-1), cocaína (12,8 2650 ng L-1), diclofenaco (8 35 ng L-1), enalapril (20 ng L-1), losartana (6,7 114 ng L-1) e valsartana (9,7 - 47 ng L-1). O ponto de coleta denominado de GU103-12 (23°4188.5S 46°4467.3W) foi a região que apresentou os valores mais elevados quanto ao nível de concentração dos compostos avaliados e ao índice de risco integrado de poluição química aquática (Integrated Risk Index of Chemical Aquatic Pollution IRICAP). O estudo também foi realizado em amostras de água de reservatórios das Unidades de Gerenciamento de Recursos Hídricos (UGRHI) 5 e 6 do Estado de São Paulo. Os resultados demonstraram que o uso e a ocupação do solo influenciam diretamente na qualidade da água dos reservatórios, evidenciando a necessidade de implementar melhorias no sistema de coleta de esgoto e de ocupação irregular para evitar a contaminação e o descarte inadequado em ambientes aquáticos. / This study presents the development of the methodology of solid phase extraction and liquid chromatography - tandem mass spectrometry, SPE-LC-MS/MS, for the determination of 21 (twenty one) pharmaceuticals belonging to different therapeutic groups, 1 (one) illicit drug and its major metabolite, in surface water samples. The chromatographic separation was optimized by studying the performance of different stationary and mobile phases. Quantitation of selected compounds was performed by electrospray ionization (ESI) and the mass spectrometer operating in a multiple reaction monitoring (MRM) mode. The validation of the proposed methodology was performed using the parameters of selectivity, matrix effect, dynamic range, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, recovery and robustness. The validation of methodology allowed to apply the methodology in the evaluation of the distribution of the 23 (twenty one) selected compounds, in Guarapiranga Dam waters, an of the major producer system of drinking water of the Metropolitan Region of São Paulo (MRSP). The presence of these pollutants in aquatic environments is from the direct release of urban sewage from the homes of your surroundings, as a result of poor sanitation system. The waters of Guarapiranga dam were evaluated in 14 (fourteen) locations strategically chosen and sampled in 3 (three) campaigns of sample collection (August 2011, September 2012 and April 2013). In these samples were quantified acetaminophen (9.6 - 254 ng L-1), atenolol (8.5 - 177 ng L-1), benzoylegonine (7.9 - 139 ng L-1), caffeine (27 - 27386 ng L-1) carbamazepine (12 - 358 ng L-1), chlorthalidone (9.4 - 35 ng L-1), cocaine (12.8 - 2560 ng L-1), diclofenac (8 - 36 ng L-1), enalapril (20 ng L-1), losartan (6.7 - 114 ng L-1) and valsartan (9.7 - 47 ng L-1). The sample siting GU103-12 (23°4188.5S 46°4467.3W) was the region with the highest values in the level of concentration of the target compounds and the integrated risk index of chemical aquatic pollution (IRICAP). The study was also conducted on water samples from reservoirs of the UGRHI (Unit of Water Resources Management) 5 and 6, State o São Paulo. The results showed that the use and occupation of land directly influence the reservoir water quality highlighting the need to implement improvements in sewage collection system and illegal occupation to prevent contamination and the improper disposal in aquatic environments.

Page generated in 0.102 seconds