• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 116
  • 43
  • 23
  • 18
  • 14
  • 10
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • Tagged with
  • 431
  • 114
  • 108
  • 95
  • 43
  • 42
  • 41
  • 40
  • 38
  • 28
  • 23
  • 22
  • 22
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Thermal Conductivity of Nanowires, Nanotubes and Polymer-Nanotube Composites

PRADHAN, NIHAR R. 14 April 2010 (has links)
Ever rising power densities and smaller transistor dimensions are increasing the challenge of thermal management within integrated-circuit chips and their surrounding packaging. In addition, the need for sustainable energy has placed urgent emphasis on energy conversion. Thermoelectric phenomena, involving the conversion of heat to electrical current, provide a central focus for both needs. Specifically, there is a need to engineer materials or composites with low thermal conductivity and high electrical conductivity for energy conversion and the opposite for heat management. In this presentation, experimental results will be presented of the specific heat and thermal conductivity of cobalt nanowires (CoNW), carbon nanotubes (CNT) and polymer-carbon nanotubes, in various composite arrangements with our high precession Calorimetric technique. Due to the nature of these samples, boundary and defect scattering of phonons in nanomaterials can dominate. This scattering phenomena shows decreasing thermal conductivity in metal nanowires, turns to be good for thermoelectric application. For the CNT, and possibly due to the high volume per atom leading to ballistic phonon propagation, the observed thermal conductivity along the nanotube direction, which leads to manage the heat dissipation problem in integrated circuits (ICs) and microprocessors. The thermal conductivity of a single Single-Wall Carbon Nanotube (SWCNT) was found to be 6600 W/mK, theoretically, twice that of diamond. When such high thermal conductivity materials are dispersed in a low thermal conducting polymer (PMMA), the effective thermal conductivity and thermal stability of the composite can change dramatically. The experimental results show good agreement with theoretical model proposed by Nelsen, Hamilton, Crosse, Geometric, and Xue. The thermal relaxation phenomena such as glass transition temperature (Tg) and dynamics of the molecules in the polymer-nanotubes composites, changes significantly different than the pure polymers during thermal treatment and is one of the focusing point of this presentation. Liquid crystalline materials confined to restrictive nano-channels are of great interest in many potential applications of electro-optics and display technology. This part of the presentation investigates the unexplored phenomenon of the coating and filling of 8CB and 10CB liquid crystals inside ~200nm diameter Multi-Wall Carbon nanopipes. The phase transition characteristics of the confined liquid crystal films were studied using MDSC technique and will be the last part of this presentation.
92

Síntese de vistas em depht-image-based rendering (DIBR) / View synthesis with depth-image-based rendering (DIBR)

Oliveira, Adriano Quilião de January 2016 (has links)
Esta dissertação investiga soluções para o problema genérico de geração de vistas sintéticas a partir de um conjunto de imagens utilizando a abordagem Depth-Image-Based Rendering. Essa abordagem utiliza um formato compacto para a representação de imagens 3D, composto basicamente por duas imagens, uma colorida para a vista de referência e outra em tons de cinza com a correspondência de disparidade para cada pixel. Soluções para esse problema beneficiam aplicações como Free Viewpoint Television. O maior desafio é o preenchimento de regiões sem informação de projeção considerando o novo ponto de vista, genericamente denominados holes, além de outros artefatos como cracks e ghosts que ocorrem por oclusões e erros no mapa de disparidade. Nesta dissertação apresentamos técnicas para remoção e tratamento de cada uma das classes de potenciais artefatos. O conjunto de métodos propostos apresenta melhores resultados quando comparado com o atual estado da arte em geração de vistas sintéticas com o modelo DIBR para o conjunto de dados Middlebury, considerando-se as métricas SSIM e PSNR. / This dissertation investigates solutions to the general problem of generating synthetic views from a set of images using the Depth-Image-Based Rendering approach. This approach uses a compact format for the 3D image representation, composed basically of two images, one color image for the reference view and other grayscale image with the disparity information available for each pixel. Solutions to this problem benefit applications such as Free Viewpoint Television. The biggest challenge is filling in regions without projection information considering the new viewpoint, usually called holes, and other artifacts such as cracks and ghosts that occur due to occlusions and errors in the disparity map. In this dissertation we present techniques for removal and treatment of each of these classes of potential artifacts. The set of proposed methods shows improved results when compared to the current state of the art generation of synthetic views using the DIBR model applied to the Middlebury dataset, considering the SSIM and PSNR metrics.
93

Applications of the Law of Large Numbers in Logistics

Bazzazian, Navid January 2007 (has links)
One of the most remarkable theories in probability and statistics is the law of large numbers. Law of large numbers describes the behavior of random phenomena when they are reiterated infinitely or in very large trials. Apart from the mathematical exposition of the law of large numbers, its theory and applications have been widely used in gambling houses, financial sectors, and healthcare insurance where uncertainties deteriorate prediction and financial strength. However, the applications of the law of large numbers are not confined to the referred sectors and could be widely applied to industrial organizations and service provider companies in which large number of stochastic phenomena incorporate in their planning. In this thesis, the applications of the law of large numbers are studied in relation to logistics and transportation under conditions of operating in large networks. The results of this study assert that transportation companies can benefit from operating in large networks to increase the filling performance of their vehicles, fleet, etc. Equivalently, according to the law of large numbers the inferior capacity utilization in unit loads, containers, etc. converges to 0 with probability 1 as the size of the network grows. / Uppsatsnivå: D
94

Aproveitamento de soro de ricota para elaboração de suplemento hidroeletrolítico / The use of ricotta cheese whey in the formulation of a hydroelectrolytic supplement

Valadão, Natali Knorr 16 October 2015 (has links)
O presente estudo consistiu na formulação, no processamento em escala piloto, na avaliação da esterilidade comercial (EC) e no estudo da vida útil de um suplemento hidroeletrolítico (isotônico) elaborado com soro de ricota. O soro de ricota deslactosado foi pasteurizado a 75 ºC/15 s, acondicionado assepticamente em garrafas plásticas e estocado a 0 ºC para ser utilizado no desenvolvimento da formulação do isotônico. O desenvolvimento da formulação contendo soro de ricota, água deionizada, corante, aroma, sacarose e cloreto de sódio foi norteado pela aplicação de testes sensoriais de Ordenação-Preferência, de Escala do Ideal e testes físico-químicos. Utilizando-se um delineamento experimental fatorial, investigou-se o binômio tempo de retenção (30 a 50 s) x temperatura de pasteurização (85 a 95 ºC) adequado à obtenção de uma bebida comercialmente esterilizada com elevada aceitação sensorial. A estabilização da bebida foi baseada na seguinte combinação de métodos térmicos e não térmicos: acidificação, pasteurização e envase asséptico. Testes físico-químicos, sensoriais e microbiológicos, incluindo o teste de EC, foram realizados na bebida recém-processada (tempo zero do estudo da vida útil (VU)). Um terço, aproximadamente, de cada lote processado foi estocado a -18 ºC (amostras controle) e dois terços estocados a 25 ºC (amostras codificadas), na ausência de luz. A estimativa da VU da bebida foi fundamentada em testes microbiológicos e sensoriais. A avaliação da estabilidade microbiológica baseou-se na enumeração de bactérias aeróbias mesófilas e a estabilidade sensorial em testes de Escala Hedônica de nove pontos para avaliação da impressão global do produto. A formulação isotônica desenvolvida atendeu aos requisitos estabelecidos pela Legislação Alimentar Brasileira, com pH 3,15, teor de sólidos solúveis de 6,4 ºBrix, osmolalidade de 306 mOsm/kg água e níveis de sódio e de potássio equivalentes a 500 e 650 mg/L, respectivamente. A bebida recém-processada apresentou contagens de bactérias mesófilas aeróbias inferiores a 10¹ UFC/mL e as médias das notas obtidas nos testes de Escala Hedônica de nove pontos alcançaram 6 (gostei ligeiramente) para o aroma e para o sabor, e situaram-se entre 6 (gostei ligeiramente) e 7 (gostei moderadamente) para a aparência. A análise estatística dos resultados revelou que somente o tempo de retenção aplicado no tratamento térmico produziu efeito significativo (p < 0,05) no sabor da bebida recém-processada, não apresentando efeitos significativos para aroma, aparência, parâmetros de cor (L*, a* e b*), pH, acidez titulável e teor de sólidos solúveis. Somente os processamentos 3 (95 ºC/50 s), 4 (90 ºC/40 s) e 5 (85 ºC/30 s) alcançaram a EC e tiveram seus tempos de VU limitados pela depreciação sensorial, estimados em 100, 128 e 153 dias, respectivamente. Os tempos de VU estimados para os lotes dos processamentos 2 (95 ºC/30 s), 6 (85 ºC/50 s) e 7 (90 ºC/40 s) foram equivalentes a 70, 42 e 42 dias, respectivamente, tendo sido limitado pelo desenvolvimento de micro-organismos, resultando em alterações na aparência da bebida e no estufamento de algumas embalagens. O lote 1 (90 ºC/40 s) teve sua vida útil estimada em 128 dias devido a falta de amostras. O soro de ricota revelou-se uma alternativa tecnologicamente viável para elaboração de um suplemento hidroeletrolítico permitindo o aproveitamento e a agregação de valor ao referido subproduto. A combinação dos métodos empregados na estabilização da bebida foi eficiente para a redução da carga microbiana inicial e para a obtenção de uma bebida com boa aceitação sensorial. / This study focused the formulation, small scale processing, commercial sterility (CS) evaluation and shelf life (SL) study of a ricotta cheese whey (RCW) based sports drink (isotonic). The RCW was pre-treated with lactase, pasteurized at 75 ºC/15 s, aseptically filled into plastic bottles and stored at 0 ºC. Then it was used to develop the isotonic formulation (RCW, deionized water, coloring, flavor, sucrose and sodium chloride) by applying Rank Preference, Just Right Scale and physicochemical tests. A factorial experiment was designed to investigate the binomial holding time (30 to 50 s) and pasteurization temperature (85 to 95 ºC) appropriate for attaining a commercially sterilized drink with a high sensory acceptance. The drink stabilization was based on the combination of thermal and non-thermal methods: acidification, pasteurization and aseptic filling. Physicochemical, sensory and microbiological tests were performed in the freshly processed drink. Approximately one third of each processed batch was stored at -18 º C (control samples) and two thirds stored at 25 ºC (coded samples), in the dark. The estimate of the isotonic shelf life relied on the microbiological and sensory tests. The microbiological stability evaluation was based on the total mesophilic aerobic counts. The sensory stability study relied on a nine-point Hedonic Scale tests. The developed formulation met the Brazilian Food Legislation and obtained acceptance average scores of 6.3, pH 3.15, soluble solids of 6.4 ºBrix, osmolality of 306 mOsm/kg água, 500 mg/L of sodium and 650 mg/L of potassium. The freshly processed product presented mesophilic aerobic bacteria counts below 10¹ CFU/mL. The average of the ratings obtained for aroma and flavor in the nine-point Hedonic Scale tests reached 6 (liked slightly); it ranged from 6 (liked slightly) to 7 (liked moderately) for appearance. The statistical analysis showed that only the holding time applied to the heat treatment had significant effect (p < 0.05) in the flavor of the drink. Neither the holding time nor the pasteurization temperature affected other sensory attributes and physicochemical parameters. Only batches 3 (95 ºC/50 s), 4 (90 ºC/40s) and 5 (85 ºC /30 s) reached the commercial sterility; their shelf lives were limited by sensory depreciation and estimated at 100, 128 and 153 days, respectively. The shelf lives for batches 2 (95 ºC/30 s), 6 (85 ºC/50 s) and 7 (90 ºC/40 s) were 70, 42 and 42 days, respectively; they were limited by the microbial growth. The findings indicate that RCW could be a technologically feasible alternative to produce a sports drink. The combination of methods employed in this study was effective in reducing the initial microbial load and obtained a drink with good acceptance.
95

Avaliação in vitro da capacidade de selamento coronário de três materiais usados como barreira adicional, em dentes tratados endodonticamente, obturados com diferentes cimentos endodônticos, utilizando o método de filtração de fluído / In vitro fluid filtration evaluation of intracoronal sealing ability of three materials used as secondary barrier

Cristiane Machado de Almeida Nishiyama 26 March 2007 (has links)
Grande parte dos insucessos dos tratamentos endodônticos ocorre por falha nas restaurações provisórias ou definitivas, em função da microinfiltração coroa-ápice. Sabe-se que, muitos pacientes realizam esse tratamento, mas não têm condições de restaurar o dente imediatamente, aumentando o risco de falhas nesse período intermediário, pela penetração de bactérias ou fluídos bucais até o canal radicular. Nos últimos anos, têm-se buscado, após o tratamento endodôntico, realizar o selamento intracoronário imediato, visando assim uma maior longevidade dessa terapia, até que se realize a restauração definitiva, ou até mesmo após esta. Diversas substâncias estão sendo testadas com o objetivo de avaliar essa penetração e existem diversos métodos disponíveis, para se avaliar a efetividade do selamento, como o de penetração de corantes e bactérias. Ultimamente, o método de filtração de fluído, que foi desenvolvido inicialmente para avaliar a permeabilidade dentinária, mas que posteriormente foi adaptado para uso em outras áreas, tem sido bastante utilizado para avaliar a microinfiltração em dentes tratados endodonticamente. Esse método é considerado quantitativo, não destrutivo, pela capacidade de se utilizar os mesmos espécimes em diferentes períodos de tempo, apresentando assim vantagens sobre os demais. Em função disso, o objetivo deste trabalho foi investigar, através do método de filtração de fluído, a permeabilidade de diferentes materiais utilizados no selamento intracoronário: o IRM, o Adper Scothbond Multi Purpose Plus e o Adper Single Bond 2, em dentes humanos unirradiculares obturados com cimento AH Plus e cones de guta percha, comparando-as entre si e também com a capacidade de selamento do novo sistema Epiphany, sendo as avaliações realizadas em períodos de 15, 30 e 60 dias. Após a aplicação do teste não paramétrico de Kruskall-Wallis e de Friedman, diferenças significantes foram encontradas entre os quatro grupos, sendo que o Grupo do IRM apresentou as maiores médias de filtrações em todos os períodos, e os grupos selados com os dois sistemas adesivos as menores. O sistema Epiphany apresentou médias iniciais baixas, mas sofreu um aumento significante dos seus valores de filtrações no último período, provavelmente por não ter recebido nenhum material selador secundário. / Great part of endodontic treatment fails because of failures in provisory or definitive restoration, permiting a coronal microleakage. For these reasons, in last years, there is a preocupation in sealing intra-coronal cavity after the treatment, to have in view a longer longevity. So many materials are being used for this purpose. Recently it has been developed by Pashley, D.H. and his collaborators, a so called \"Fluid Transport method and capillary flow\" by the method of fluid transport. This method was inicitially developed for measuring dentinal permeability and is now used for studying the microleakage of root filling materials throuhg seal of intra-coronal fillings. It is not a destructive and quantitative method that permits the observation of the same specimens in different periods of time. The aim of the present study is to evalute the fluid infiltration and permeability of intracoronal sealers, using two Endodontics cements. 40 human teeth were divided into two grups. Group I, with 30 teeth, canals were filled with gutta-percha cones and AH Plus cement. Group II, with 10 teeth, canals were filled with Epiphany System. Four millimeters of the material was placed on the pulp chamber floor. Group I was divided in three groups: In Group IA, after canal filling, pulp chambers were filled with temporary filling IRM. In Group IB, pulp chambers were sealed with Socth Bond Multi Purpose Plus and Group IC, pulp chambers were sealed with Adper Singlebond. In Group II no sealing was made in pulp chambers of teeth. The fluid filtration for each group was compared by Kruskal-Wallis test. In the 15 days period, low filtration indexes had been observed in all groups, but Group IC presented the lowest level of filtration results. In the 30 days period, IA group behaved as expected, the IRM permiting the larger filtration. The groups IB, IC e II, perminting layer filtration than in the 15 days period. In the 60 days period, the group II presented higher level of filtration but the groups IB e IC presented the lost results of filtration, could being considered equally efficients, and the group IA demonstred the poorest results. In conclusion all groups showed filtration in 15, 30 and 60 days period.
96

Análise da cimentação e da resistência de união de dois diferentes tipos de pinos de fibra de vidro em dentes com reabsorções radiculares internas simuladas /

Abreu, Ricardo Toledo. January 2019 (has links)
Orientador: Cláudio Antonio Talge Carvalho / Coorientador: Carlos Rocha Gomes Torres / Banca: César Rogério Pucci / Banca: Flávia Goulart da Rosa Cardoso / Resumo: Este estudo analisou a interface de união e a força de adesão dos pinos de fibra de vidro Rebilda Post (RP) (VOCO) e Rebilda Post GT (GT) (VOCO) após cimentação em dentes com Reabsorção Radicular Interna (RRI) simulada. Quarenta e cinco raízes de pré-molares inferiores humanos foram padronizadas em 16 mm e incluídas em resina acrílica. Os canais radiculares (CR) foram preparados biomecanicamente, as raízes foram seccionadas em sua metade e a RRI foi simulada. Os segmentos foram retornados à posição original com auxílio de parafusos. Uma pasta de Ca(OH)2 permaneceu como MIC por 15 dias. A remoção foi feita por PUI e a qualidade da limpeza foi avaliada por estereomicroscopia. Os CR das amostras foram obturados e o preparo foi feito de forma padronizada. Os espécimes foram divididos em 2 grupos (n=20), de acordo com o tipo de pino cimentado. A resistência de união foi avaliada aos níveis cervical e da RRI pelo teste push-out. Para a análise estatística só foram incluídas falhas adesivas e predominantemente adesivas. Os resultados foram submetidos ao teste de Kruskal-Wallis, Mann Whitney e teste de Dunn (α = 0,05). Foi realizada MEV para análise da interface de união entre cimento e dentina radicular (n=1) e análise por microtomografia computadorizada (micro-CT) do pino GT (n=3). PUI não foi capaz de limpar completamente a maioria das RRI (62,5%). Houve alteração da resistência adesiva entre todos os grupos (p <0,05). Os valores de resistência de união para ambos os grupos na reg... (Resumo completo, clicar acesso eletrônico abaixo) / ABSTRACT : This study analyzed the adhesion interface and bond strength of Rebilda Post (RP) (VOCO) and Rebilda Post GT (GT) (VOCO) glass fibers after cementation in teeth with simulated Internal Root Resorption (IRR). Forty-five roots of lower human premolars were standardized at 16 mm and included in acrylic resin.The root canals (RC) were prepared biomechanically, the roots were sectioned and the IRR was simulated.The segments were returned to original position with the aid of screws. A Ca(OH)2 paste remained as MIC for 15 days.The removal was done by PUI and the quality of the cleaning was evaluated by stereomicroscopy. The RC of the samples were filled and the preparation was done in standardized way. The specimens were divided into 2 groups (n=20), according to the type of cemented post. The bond strength was evaluated at the cervical and RRI levels by the push-out test. For the statistical analysis only adhesive and predominantly adhesive failures were included. The results were submitted to Kruskal-Wallis test, Mann Whitney test and Dunn test (α =.05). SEM was used to analyze the bond interface between cement and dentin root (n=1) and Microcomputed tomography (micro-CT) analysis of the GT post (n=3). PUI was not able to clear completely the majority of RRI (62.5%). There was alteration of the adhesive resistance between all groups (p <.05). The values of bond strength for both groups in the cervical region were higher in relation to the groups in the RRI region.The SEM showed formation of resin tags at the bond interface between resin cement and root dentin for both groups. In micro-CT analysis, the presence of bubbles in the cement and spaces in the bond interface between cement are visible. The adhesion of both posts was affected negatively by the level of cementation, post adaptation in the root canal and presence of IRR. Rebilda Post presented better ...(Complete abstract click electronic access below) / Mestre
97

\"Quantificação, por diferentes métodos, de material obturador remanescente no interior de canais radiculares, após desobturação e repreparo\" / Quantity, through different methods, of the remaining material, after deobstruction and re-instrumentation

Masiero, Anelise Viapiana 01 November 2006 (has links)
O presente estudo teve por objetivo avaliar comparativamente o emprego de tomografias e cortes transversais na quantificação de material obturador endodôntico remanescente à desobturação e repreparo dos canais radiculares. Para tal, 32 dentes preparados, obturados e após periodo necessário para o ennvelhecimento do cimento obturador foram desobturados e repreparados. Os espécimes tiveram o conteúdo de material obturador remanescente avaliado por diferentes métodos: aferição em tomógrafo computadorizado de múltiplos detectores e aferição em software Leica Qwin. Inicialmente foram medidos os volumes de material obturador remanescente no tomógrafo computadorizado com os espécimes ainda íntegros. Em seqüência, realizou-se nos mesmos cortes transversais com espessura de 1mm permitindo assim aferição: do volume em tomógrafo computadorizado após o corte; das áreas de material remanescente em cada corte com auxílio do software Leica Qwin. Para que fosse possível a comparação dos métodos, os valores de área foram utilizados para cálculo do volume de material remanescente em cada espécime através da fórmula do volume do cone truncado. Os resultados obtidos foram submetidos a análise pelo teste t de Student para dados vinculados, o qual identificou diferença estatisticamente significante em nível de 5% na quantificação de material obturador remanescente quando da comparação dos volumes obtidos com a análise do software Leica Qwin e aplicação da fórmula do volume do cone 11 truncado aos volumes obtidos pelas aferições tomográficas, sendo que a análise dos cortes pelo software Leica Qwin permitiu maior quantificação de material, mostrandose método adequado para análise. Em relação ao método tomográfico não houve diferença estatística significante entre a avaliação do remanescente de material obturador nos cortes ou nos espécimes íntegros. / The aim of the present study was to evaluate the effectiveness of computed tomography and cross section in quantifying the remaining filling material during retreatment. For that, 32 teeth were prepared, filled and after the period necessary to the sealer set, the specimens had their filling material removed and were reprepared. The amount of filling material were evaluate for different methods: computed tomography and Leica Qwin software. First, the volumes of filling material remaining were measured through the computed tomography with the specimens still entire. After, they were cross sectioned with a thickness of 1mm allowing measure of: the volume through computed tomography and the areas of remaining material in which section through the Leica Qwin software. To allow a comparative analysis among methods, the area values were used to calculate the filling material remaining volume using the truncated cone formula. The results were submitted to the t Student test for linked data which identify a significant difference to the level of 5% in the quantification of remaining material when the comparison of the volumes obtained after Leica Qwin analysis and application of truncated cone formula in relation to the results obtained from computed tomography, being the first method that allow the bigger quantification, therefore, most efficient. In relation the tomographic method there was no significant difference between the measured made in the intact specimen or after they were cross-sectioned.
98

Avaliação qualitativa e quantitativa da instrumentação e obturação de canais radiculares achatados utilizando-se microtomografia computadorizada / Qualitative and quantitative evaluation of instrumentation and obturation of flat root canals using computed microtomography

Iglecias, Elaine Faga 01 August 2014 (has links)
Na Endodontia, a microtomografia (CT) tem sido amplamente utilizada como método de análise tridimensional. Atualmente, três movimentos mecanizados para o preparo do canal radicular tem sido introduzidos na rotina endodôntica, oscilatório, rotatório e recíproco. Existem diferentes sistemas de limas acionadas por motores capazes de realizar esses movimentos. Sendo assim, os objetivos deste trabalho são utilizar a CT para avaliar, em canais mesiais achatados de molares inferiores, a qualidade e modelagem final de preparo do canal radicular, utilizando-se sistemas oscilatório, recíproco e rotatório e avaliar a obturação do canal radicular com cone único ou ondas contínuas de condensação, no que diz respeito ao volume de material obturador e de espaços vazios. Os resultados não mostraram diferença estatísitica significativa no volume de desgaste entre os grupos testados. Para a porcentagem de superfície não tratada os grupos oscilatório e rotatório tocaram mais paredes nos terços cervical e médio do que o grupo recíproco. A técnica de ondas contínuas de condensação e cone único apresentaram preenchimento de obturação semelhantes nos terços médio e apical, sendo que no terço cervical a técnica de ondas contínuas deixou menor porcentagem de espaços vazios. / Endodontics in the microtomography (CT) has been widely used as a method for three-dimensional analysis. Currently, three mechanized movements for root canal preparation has been introduced in endodontic, oscillatory, rotational and reciprocal routine. There are different files systems driven by motors capable of these movements. Thus, the objectives of this work are using CT to evaluate, in flattened mesial canals of mandibular molars, the quality and final modeling of root canal preparation, using oscillatory, reciprocal and rotational systems and evaluate the root canal filling with single cone or continuous waves of condensation, with respect to the volume of filling material and voids. The results showed no significant difference in estatísitica wear volume between the tested groups. For the percentage of untreated surface and the oscillating rotating groups played more walls in the cervical and middle thirds of the reciprocal group. The technique of continuous wave of condensation and single cone showed similar fillings fill in the middle and apical thirds, and in the cervical third of the technique of continuous wave left lower percentage of voids.
99

"Avaliação da vedação apical proporcionada por três materiais retroobturadores" / Evaluation of sealing ability of three root-end filling materials

Panzani, Claudia 14 December 2005 (has links)
A cirurgia parendodôntica é um recurso utilizado para solucionar casos em que a terapia endodôntica não obteve sucesso, ou ainda na impossibilidade da sua realização. A escolha de um material retroobturador adequado pode contribuir positivamente para o reparo tecidual. Este estudo teve como objetivo avaliar a capacidade seladora de três materiais usados para retroobturação, em dois tempos diferentes, tendo como marcador o corante Rodamina B a 0,2%. Sessenta e seis dentes tiveram as suas coroas seccionadas, os canais preparados com limas manuais e obturados com cimento e guta-percha. Seccionaram-se dois milímetros da porção apical e cavidades retrógradas foram preparadas com pontas de ultra-som lisas; dividindo-se então, em 3 grupos experimentais que receberam os seguintes materiais: MTA Ângelus ® , Real Seal ® e um material experimental desenvolvido pelo IPEN-USP (Instituto de Pesquisas Energéticas e Nucleares da Universidade de São Paulo). Dez elementos de cada grupo foram imersos em soro fisiológico durante 72h a 37°C, antes de serem impermeabilizados e colocados no corante por 24h (grupos I A, II A e III A). Os demais permaneceram 60 dias em soro fisiológico para depois serem impermeabilizados e colocados no marcador (grupos I B, II B e III B). O controle positivo consistiu de 3 espécimes, que não tiveram as cavidades retroobturadas. Outros três espécimes serviram como controle negativo, cada um foi retroobturado com um dos materiais em estudo e foram totalmente impermeabilizados antes de serem imersos no corante. Após o tempo de imersão no corante, todos os espécimes foram lavados, e em seguida, clivados ongitudinalmente no sentido mésio-distal. As superfícies foram avaliadas em lupa estereoscópica com aumento de 20X e fotografadas. A infiltração linear foi medida com auxílio de uma lente reticulada e régua milimetrada. Os resultados foram submetidos aos testes estatísticos de Kruskal-Wallis e verificou-se que não houve diferença entre os grupos do MTA Ângelus ® e do Real Seal ® , sendo que a maior infiltração do corante ocorreu na interface dentina-material experimental, com diferença estatisticamente significante ao nível de 1% (a=0,01). Fazendo a análise estatística de Mann-Whitney entre os grupos com o mesmo material, verificou-se que o tempo de permanência em umidade até 60 dias não influenciou na vedação dos materiais retroobturadores. / Apical surgery is a resource that is used to solve cases in which endodontic therapy was either unsuccessful or could not be done. Choice of root-end filling material contributes for successful. The purpose of this study was to evaluate the sealing ability of three materials used for root-end filling, using 0.2% Rhodamine B. Sixty-six teeth had their crowns removed, and their canals were cleaned and shaped with manual files, and filled with cement and gutta-percha. Two millimeters of the apical portion were sectioned and root-end cavities were prepared in all specimens with smooth ultrasonic tips. Three groups were formed to receive the following materials: MTA Ângelus ® , Real Seal ® , and an experimental material developed by the IPEN-USP (Institute of Energetic and Nuclear Research from São Paulo University). Ten specimens from each group were immersed in a physiological saline solution for 72h at 37°C, before being waterproofed and put in the colorant for 24 h (groups I A, II A, and III A). The others remained in physiological saline solution for 60 days and were then waterproofed and put in the marker (groups I B, II B, and III B). The positive control consisted of three specimens that did not have their cavities root-end filled. Another three specimens served as a negative control, each being root-end filled with one of the materials being studied, and they were totally waterproofed before being immersed in Rhodamine B. After the time of immersion in the colorant, all of the Speci mens were washed and then cleaved longitudinally in the mesio-distal direction. The surfaces were evaluated under a stereoscopic magnifying glass at 20X magnification and photographed. The linear infiltration was measured with a micro metered lens and millimeter rule . The results were submitted to the Kruskal-Wallis statistical tests and it was noticed that there was no difference between the MTA Ângelus ® and Real Seal ® groups. The experimental material presents the most colorant microleakage, with a statistically significant difference (a=0.01). The Mann-Whitney statistical analysis performed in the groups with the same material showed that the period of time the specimen remained exposed to moisture - up to 60 days - did not impact the materials’ sealing capacity.
100

Sum-rate maximization for active channels

Javad, Mirzaei 01 April 2013 (has links)
In conventional wireless channel models, there is no control on the gains of different subchannels. In such channels, the transmitted signal undergoes attenuation and phase shift and is subject to multi-path propagation effects. We herein refer to such channels as passive channels. In this dissertation, we study the problem of joint power allocation and channel design for a parallel channel which conveys information from a source to a destination through multiple orthogonal subchannels. In such a link, the power over each subchannel can be adjusted not only at the source but also at each subchannel. We refer to this link as an active parallel channel. For such a channel, we study the problem of sum-rate maximization under the assumption that the source power as well as the energy of the active channel are constrained. This problem is investigated for equal and unequal noise power at different subchannels. For equal noise power over different subchannels, although the sum-rate maximization problem is not convex, we propose a closed-form solution to this maximization problem. An interesting aspect of this solution is that it requires only a subset of the subchannels to be active and the remaining subchannels should be switched off. This is in contrast with passive parallel channels with equal subchannel signal-tonoise- ratios (SNRs), where water-filling solution to the sum-rate maximization under a total source power constraint leads to an equal power allocation among all subchannels. Furthermore, we prove that the number of active channels depends on the product of the source and channel powers. We also prove that if the total power available to the source and to the channel is limited, then in order to maximize the sum-rate via optimal power allocation to the source and to the active channel, half viii ix of the total available power should be allocated to the source and the remaining half should be allocated to the active channel. We extend our analysis to the case where the noise powers are unequal over different subchannels. we show that the sum-rate maximization problem is not convex. Nevertheless, with the aid of Karush-Kuhn-Tucker (KKT) conditions, we propose a computationally efficient algorithm for optimal source and channel power allocation. To this end, first, we obtain the feasible number of active subchannels. Then, we show that the optimal solution can be obtained by comparing a finite number of points in the feasible set and by choosing the best point which yields the best sum-rate performance. The worst-case computational complexity of this solution is linear in terms of number of subchannels. / UOIT

Page generated in 0.0485 seconds