• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 1
  • 1
  • Tagged with
  • 26
  • 8
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Modificação do método rápido de Scharer para detecção, com alta sensibilidade, da fosfatase alcalina residual em manteiga / Modification of the fast method of Scharer for detection, with high sensitivity, of the residual alkaline phosphatase in butter

Silva, Cláudia Aparecida de Oliveira e 13 November 2006 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-11-16T17:20:59Z No. of bitstreams: 1 texto completo.pdf: 764514 bytes, checksum: aa9d645c1f4fe618a50dce6c80ef334e (MD5) / Made available in DSpace on 2016-11-16T17:20:59Z (GMT). No. of bitstreams: 1 texto completo.pdf: 764514 bytes, checksum: aa9d645c1f4fe618a50dce6c80ef334e (MD5) Previous issue date: 2006-11-13 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A fosfatase alcalina (ALP) é uma enzima naturalmente presente no leite. Suas concentrações variam de acordo com a raça do animal, alimentação, período de lactação, produtividade e ao longo das estações do ano. A ALP é inativada pelas temperaturas de pasteurização, assim, a avaliação da atividade residual desta enzima é utilizada na indústria de laticínios para determinar a eficiência do tratamento térmico aplicado aos produtos lácteos. Todavia, trabalhos sobre a atividade desta enzima em manteiga são escassos, principalmente no Brasil, onde esta análise não é um procedimento obrigatório na avaliação da qualidade de manteiga, como ocorre nos Estados Unidos e em países da Europa. De acordo com a Food and Drug Administration (FDA), o limite máximo permitido de atividade residual da ALP em leite e produtos lácteos pasteurizados é de 350,0 mU/Kg de produto, pelo método fluorimétrico. Neste trabalho, os valores médios encontrados para a atividade desta enzima no creme cru padronizado (entre 40,0 e 41,0% de gordura) durante o verão, o outono e o inverno, pelo método fluorimétrico, foram de 17.264.214 + 2.554.645, 17.719.500 + 5.476.910 e 14.196.714 + 1.375.055 mU/L, respectivamente. Foram analisadas amostras de manteigas comerciais quanto às quantidades residuais da ALP, avaliou-se a sensibilidade e o limite de detecção do método rápido de Scharer, visual e espectrofotométrico, em comparação com o método fluorimétrico e modificou-se o método rápido de Scharer, obtendo-se uma nova metodologia, de alta sensibilidade e de custo mais acessível para determinação da atividade residual da ALP em manteiga. Dentre as vinte amostras de manteigas comerciais analisadas, quatro (20%) apresentaram resultado positivo para atividade residual da ALP, sendo duas da marca A e as outras duas das marcas B e E. Duas amostras da marca E apresentaram reativação da enzima, não confirmando assim o resultado positivo inicial. Para a avaliação da sensibilidade do método rápido de Scharer, manteigas foram fabricadas a partir de creme pasteurizado adicionado de quantidades de 0,000%; 0,010%; 0,015%; 0,025%; 0,050% e 0,100% (v/v) de creme cru. Por meio do método visual foi possível detectar apenas concentrações a partir de 0,050% de creme cru, não apresentando sensibilidade condizente com o método fluorimétrico. O método espectrofotométrico foi mais sensível, sendo capaz de detectar a concentração de creme cru correspondente ao limite estabelecido, mas que não correspondia à concentração de creme cru e à quantidade de fenol/g de amostra preconizadas por alguns autores como indicativos de pasteurização ineficiente (0,1% de contaminação com creme cru e 1,0 μg de fenol/g de amostra, respectivamente). O desenvolvimento da nova metodologia baseou-se na realização de modificações no método rápido de Scharer. Utilizou-se alíquotas de 0,5 mL de fase aquosa para a análise da atividade da ALP, em substituição à alíquota de 0,5 g de manteiga, utilizada no método convencional. A fase aquosa foi obtida a partir da fusão da manteiga a 45 oC e subseqüente centrifugação a 1200 x g por 10 minutos. Nas amostras avaliadas, foi possível distinguir visualmente as manteigas com atividade igual ou próxima a 350,0 mU/Kg (coloração esverdeada) das manteigas pasteurizadas (coloração amarela) e dos controles negativo e de interferentes. Na análise espectrofotométrica, obteve-se um valor médio para a atividade residual da ALP de 0,115 μg de fenol por amostra (0,5 g de manteiga) de manteiga, pelo método rápido de Scharer convencional e 0,385 μg de fenol por amostra (0,5 mL de fase aquosa), pelo novo método desenvolvido. Estes valores sugerem que a sensibilidade do método convencional foi aumentada em, aproximadamente, 3,3 vezes. O método modificado apresentou limite de detecção da atividade da ALP de acordo com os limites estabelecidos pela FDA, e constitui uma alternativa de custo mais acessível para a determinação de baixas concentrações residuais desta enzima em manteiga. / The alkaline phosphatase (ALP) is enzyme naturally present in the milk. It s concentration depends the animal breed, feed, period of lactation, yield, season the year. In this work, mediums values for the activity this enzyme in the padronized raw cream (40,0% to 41,0% of fat) during the summer, the fall and the winter using the fluorimetric was 17.264.214 + 2.554.645, 17.719.500 + 5.476.910 and 14.196.714 + 1.375.055 mU/L, respectively. The analyses of ALP is used in the dairy industry to determine efficient the pasteurization. However, scientific works about this enzyme in cream are scarce, mainly in Brazil, where his analyses isn t an obliged procedure for assessment the quality butter, how happen in another countries. According to Food and Drug Administration (FDA), the maximum residual of ALP in pasteurized milk and dairy products by the fluorimetric method must be below 350 mU/Kg. There have been analyzed residual ALP, the sensitivity and the limit of detection of commercial butter samples, by visual Scharer and spectrophotometric method to compared with fluorimetric method and new method with high sensitivity was developed and its cost is smaller for determination residual ALP butter. Of the 20 samples commercials butter four (20%) presented positive resulted residual ALP, two was brand A and another two is brand B and E. Two samples of brand E presented enzyme s reactivation, didn t have confirm the initial positive resulted. In the assessment of sensitivity method Scharer s rapid visual, butters were obtained by addition in different proportions: 0,000%; 0,010%; 0,015%; 0,025%; 0,050% and 0,100% (v/v) of raw cream. The visual method was able to detect only concentrations by addition 0,050% raw cream, doesn t presented sensitivity in accordance with method fluorimetric. The spectrophotometric method was more sensitive, because detect concentration of raw cream corresponding detection limit, but it doesn t corresponded the concentration of raw cream and magnitude phenol/g of sample recognized by several authors that indicated incorrectly pasteurized using this method (0,1% of contamination with raw cream and 1,0 μg phenol/g by sample, respectively). The development new method consists in modification in the fast method of Scharer. There have been used 0,5 ml of water phase for analyses ALP, in replacement to the aliquot 0,5 g butter, used in the conventional method. The water phase was obtained by butter fusion 45 °C and followed centrifugation 1200 x g for 10 minutes. In the six repetitions, was possible distinguish visually butter with equal activity or near a 350 mU/Kg ( limits butters ) by pasteurized butters and controls negative and interferents. In the analyses spectrophotometric, it got a value medium residual ALP 0, 115 μg phenol for sample (0,5g of butter), using the conventional method Scharer s rapid and 0,385 μg de phenol for sample (0,5 mL water phase), using the new method development. These values suggest sensitivity conventional method was increase approximately 3,3 times. The modified method presented limit detection of ALP in accordance with establishment FDA so it is an alternative with lower costs for detection the lower residuals levels this enzyme in butter. / Não foi localizado o cpf do autor.
12

[en] DEVELOPMENT OF ANALYTICAL METHODS BASED ON LUMINESCENCE AND ELECTROPHORESIS FOR THE DETERMINATION OF ALKALOIDS (BETA-CARBOLINES, CAMPTOTHECIN AND DERIVATIVES) OF PHARMACOLOGICAL INTEREST / [pt] DESENVOLVIMENTO DE MÉTODOS ANALÍTICOS ESPECTROLUMINESCENTES E ELETROFORÉTICOS PARA A DETERMINAÇÃO DE ALCALOIDES (BETA-CARBOLINAS, CAMPTOTECINA E DERIVADOS) DE INTERESSE FARMACOLÓGICO

FLAVIA FERREIRA DE CARVALHO MARQUES 14 October 2009 (has links)
[pt] Métodos analíticos foram desenvolvidos para a determinação seletiva de alcalóides de interesse farmacológico. Com o objetivo de permitir a determinação seletiva de camptotecina (CPT) em formulações farmacêuticas de irinotecana (CPT-11) ou de topotecana (TPT), dois métodos espectrofluorimétricos e um eletroforético, com detecção por fotometria de absorção, foram propostos. Os métodos espectrofluorimétricos permitiram a determinação seletiva de CPT usando um ajuste de alcalinidade do meio associado ao uso de varredura sincronizada ou de derivada de 2ª ordem. Alternativamente, o procedimento de derivação fotoquímica (com otimização com planejamento composto central) eliminou completamente as interferências no sinal do CPT. Nas condições otimizadas, a espectrofluorimetria permitiu a determinação de CPT em misturas contendo até 50 vezes mais TPT ou contendo até 10 vezes mais CPT-11. A resposta analítica indicou faixas lineares de trabalho e homoscedasticidade. O limite de detecção (LD) foi da ordem de 10(-10) mol L(-1) para o método baseado na derivação fotoquímica e uma ordem de grandeza a menos para os métodos sem derivatização fotoquímica. Testes foram feitos em medicamentos a base de TPT e de CPT-11 e as recuperações ficaram em torno de 100%. Esses resultados foram comparáveis aos obtidos com método de referência (HPLC). O estudo de incerteza de medição por fluorimetria indicou que a maior contribuição do processo era a preparação de solução por avolumação. A contribuição dessa fonte foi minimizada pela preparação de solução por meio de ajuste de massa, causando um grande impacto na redução da incerteza expandida. O método baseado na eletroforese eletrocinética capilar micelar (MEKC) permitiu a quantificação simultânea de TPT, CPT e CPT-11. Para conseguir o ajuste final das melhores condições, foi feito um estudo univariado seguido de um planejamento composto central. Para se melhorar a sensibilidade da detecção em até 76 vezes, foi utilizado um processo de pré-concentração no capilar por modo de empilhamento e uma cela de caminho óptico alongado. A escolha do tampão borato (pH 8,5) contendo SDS e acetonitrila permitiu condições robustas 7 de sinal de tempo de migração. A resposta analítica mostrou faixa linear e homoscedatidade, além de repetitividade em torno de 3,5%. O LD foi da ordem de 10(-7) mol L(-1) (TPT) e 10(-8) mol L(-1) (CPT-11 e CPT). Testes de recuperação em amostras de saliva fortificadas foram feitos e comparados com os obtidos por um método de referência (HPLC) de forma a mostrar a exatidão adequada para o método proposto. Para a determinação seletiva de B-carbolinas, a fosforimetria em substrato sólido (SSRTP) foi utilizada. O ajuste do átomo pesado seletivo e a aplicação de técnica de varredura sincronizada e de 2ª derivada aumentaram o grau de seletividade, pois induziu fosforescência dos analitos de interesse na amostra e melhorou a resolução espectral em relação aos interferentes. O ajuste da quantidade de HgCl2 (0,81 mg) permitiu a determinação seletiva de harmol na presença de quantidades até 10 vezes maiores de harmine, harmane, norharmane e harmaline. O método SSRTP seletivo proposto para determinação de harmol foi comparado com o resultado obtido por um método de referência adaptado baseado em MEKC, o qual também mostrou sua capacidade para a determinação seletiva de harmol na presença dos interferentes. LD absoluto na ordem de ng e comportamento linear da resposta analítica foram obtidos. No caso do método analítico desenvolvido para a determinação de harmane na presença de harmine em chás, estudos de otimização mostraram o AgNO3 como sal de átomo pesado no substrato, solução de amostra em pH 11 e medições feitas em 322 nm do espectro de 2ª derivada da varredura sincronizada ((delta)(lambda) = 109 nm). Testes de interferência mostraram que a matriz do chá não tem influência no sinal do harmane e que nas / [en] Analytical methods were developed for the selective determination of alkaloids of pharmacological interest. Aiming the selective determination of camptothecin (CPT) in irinotecan (CPT-11) or topotecan (TPT) based pharmaceutical formulations, two spectrofluorimetric methods and one electrophoretic method with absorciometic detection were proposed. The spectrofluorimetric method allowed the determination of CPT using the adjustment of the alkalinity of the sample solution associated with the use of synchronous scanning or 2nd order spectral derivation. Alternativelly, the photochemical derivatization (optimized by central composite design) completely eliminated interferences on the CPT signal. The optimized conditions allowed the spectrofluorimetric determination of CPT in mixtures containing up to 50 times more TPT or up to 10 times more CPT-11. The analytical response presented linear working ranges and homocedasticity. The limit of detection (LD) was in the order of 10(-10) mol L(-1) for the method based on photochemical derivatization and one order of magnitude higher for the methods without photochemical derivatization. Tests were made using TPT and CPT-11 based comercial drugs and recoveries were around 100%. Such results were comparable to those obtained with the reference method (HPLC). A study of fluorimetric measurement uncertainty indicated that the greatest contribution in the process was the preparation of solution by volume. The contribution from this source was minimized by the preparation of solutions by weight measurement which caused a major impact in reducing the expanded uncertainty. The method based on micellar electrokinetic capillary electrophoresis (MEKC) allowed the simultaneous quantification of TPT, CPT and CPT-11. To achieve final adjustment of conditions, an univariated study was made followed by a central composite design. To improve the sensitivity of detection up to 76 times, a pre-concentration in the capillary by the normal stacking mode was used along with an extended optical path cell. The choice of borate buffer (pH 8.5) containing SDS and acetonitrile implicated in robust conditions of signal and migration times. The response showed analytical linear working range and homocedasticity, and 9 repeatability of around 3.5%. The LD was in the order of 10(-7) mol L(-1) (TPT) and 10(-8) mol L(-1) (CPT-11 and CPT). Recovery tests using spiked saliva samples were made and compared with those obtained by a reference method (HPLC) to show the appropriated accuracy for the proposed method. For the selective determination of B-carbolines, solid surface room temperature phosphorimetry (SSRTP) was used. The adjustment of the selective heavy atom and the application of synchronized scanning technique and 2nd order spectral derivation, increased the degree of selectivity, because induced phosphorescence of the analytes of interest in the sample and improved spectral resolution. The adjustment of the amount of HgCl2 (0.81 mg) allowed the selective determination of harmol in the presence of up to 10 times higher amounts of harmine, harman, harmaline and norharman. The method proposed for selective SSRTP determination of harmol was compared with the results obtained by an adapted method based on MEKC, which also showed its ability to determine harmol in the presence of interferences. The absolute limit of detection in the ng order and linear behavior of the analytical response was obtained. For the analytical method developed for the determination of harman in the presence of harmine in teas, optimization studies indicated the following conditions: AgNO3 as the heavy atom salt deposited on the substrate, sample solution at pH 11 and measurements made at 322 nm of the 2nd order derivated synchronous scanning spectrum ((delta)(lambda) = 109 nm). Tests showed that, in optimized conditions, the tea matrix had no influence on the harman signal and and that harman could be determined in samples containing harmine in concentrations up to two times higher. The
13

Desenvolvimento de um fluorímetro microcontrolado para determinação de clorofila a em águas superficiais

Guerreiro, Thiago Brito 29 July 2010 (has links)
Made available in DSpace on 2016-06-02T20:36:26Z (GMT). No. of bitstreams: 1 3179.pdf: 1125649 bytes, checksum: 2420c47e3cef37ca39869c4481c09bd0 (MD5) Previous issue date: 2010-07-29 / Universidade Federal de Sao Carlos / In this work a portable fluorimeter was developed and used for determination of chlorophyll a in water samples. The instrument was constructed using the following components: a microcontroller (PIC18F4550), two LEDs as light source, a multichannel photodiode (TCS-230) as detector and a digital display. LEDs with maximum emission at 405 and 760 nm were used. The detector is equipped with three internal optical filters inside with maximum sensitivity at 480, 540 and 690 nm besides the possible use without the optical filter with high sensitivity in the visible spectral region with maximum sensitivity at 680 nm. The microcontroller works as central processing unit controlling all components of the instrument by a program previously recorded in its memory eliminating the need of a microcomputer. The fluorimeter was calibrated using standard solutions of fluorescein and rhodamine 6G in HCl 1.0 x 10-5 mol L-1 and performance was compared with a commercial spectrofluorimeter, and the results are in agreement at a confidence level of 95%. A linear response range for fluorescein was obtained between 0.5 and 100.0 x 10-6 mol L-1 and a correlation coefficient of 0.996 and for rhodamine 6G a linear response range between 0.2 and 10.0 x 10-6 mol L-1 was obtained and a correlation coefficient of 0.989. The fluorimeter was used for determination of chlorophyll a in water samples and blue algae culture medium. The results were compared with a spetrophotometric method and were in agreement at a confidence level of 95%. A linear range of between 2.5 and 1333.6 x 10-6 g L-1 for chlorophyll a was obtained with a correlation coefficient of 0.995. The concentration range attend the requirements of CONAMA resolution n° 357 that classifies the water quality covering the concentrations of 10.0, 30.0 and 60.0 x 10-6 g L-1 for different classes of water. The fluorimeter is inexpensive, easy to use shows, low power consumption allowing the feed with batteries, small size (10 cm x 20 cm x 15 cm) and with weight of 0.76 kg. The fluorimeter can be used to determine species with excitation at 405 and or 476 nm and emission across the visible range with excellent performance. / Neste trabalho foi desenvolvido um fluorímetro portátil para determinação de clorofila a em águas superficiais. O instrumento foi construído utilizando os seguintes componentes: um microcontrolador (PIC18F4550), dois LEDs como fonte de radiação, um fotodiodo multicanal (TCS-230) como detector e um mostrador digital. Foram utilizados LEDs com máximo de emissão em 405 e 476 nm. O detector utilizado é dotado de três filtros ópticos internos com máximos de transmissão em 480, 540 e 680 nm permitindo, ainda a sua utilização sem os filtros com elevada sensibilidade em toda a região do espectro visível(máximo em torno de 690 nm). O microcontrolador atua como unidade central de processamento sendo todos os componentes do instrumento controlados por ele a partir de um programa previamente gravado em sua memória, dispensando o uso de um microcomputador. O fluorímetro construído foi calibrado utilizando soluções de fluoresceína e rodamina 6G em solução de HCl 1,0 x 10-5 mol L-1 e o desempenho foi comparado com um espectrofluorímetro de bancada, sendo os resultados obtidos concordantes a nível de confiança de 95%. Foi obtida uma faixa de resposta linear para fluoresceína entre 0,5 e 100,0 x 10-6 mol L-1 e um coeficiente de correlação de 0,996 e para rodamina 6G uma faixa linear de resposta entre 0,2 e 10,0 x 10-6 mol L-1 e um coeficiente de correlação de 0,989. A instrumentação desenvolvida foi utilizada para a determinação de clorofila a em amostras de água superficiais e em amostras de meio de cultura de algas azuis e os resultados foram concordantes ao nível de significância de 95 % quando comparados com um método comparativo espectrofotométrico. Para a clorofila a obteve-se uma faixa de concentração entre 2,5 e 1333,6 x 10-6 g L-1 e um coeficiente de correlação linear de 0,995. O intervalo obtido atende à resolução CONAMA n° 357 que dispõe sobre a classificação da qualidade de corpos d água que estabelece as concentrações de 10,0, 30,0 e 60,0 x 10-6 g L-1 para os diferentes tipos de classes de águas. O fluorímetro construído é de baixo custo, de fácil utilização, de baixo consumo de corrente permitindo sua utilização com pilhas ou baterias e de reduzidas dimensões (10 cm x 20 cm x 15 cm) com massa total de 0,76 kg. O fluorímetro pode ser utilizado na determinação de espécies com excitação em 405 e/ou 476 nm e emissão em toda a faixa do visível com excelente desempenho.
14

Eficácia de óleos minerais aplicados como adjuvantes auxiliando na selitividade de herbicidas na cultura de cana-de-açúcar

Santos, Eigon Costa dos [UNESP] 04 March 2015 (has links) (PDF)
Made available in DSpace on 2015-08-20T17:10:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-04. Added 1 bitstream(s) on 2015-08-20T17:26:01Z : No. of bitstreams: 1 000844553.pdf: 649450 bytes, checksum: 76496516946dcfd86a01aa958e7ed9b6 (MD5) / Os adjuvantes são substâncias adicionadas à formulação dos defensivos agrícolas com o intuito de melhorar a eficácia desses produtos. O objetivo do presente trabalho foi avaliar a eficácia de óleos minerais como adjuvantes de herbicidas utilizados na cultura da cana-de-açúcar. O trabalho foi dividido em três experimentos com focos em controle de plantas daninhas em pré e pós-emergência e em erradicação da soqueira de cana-açúcar. O delineamento experimental utilizado nos experimentos foi o de blocos ao acaso, com vinte tratamentos e quatro repetições para cada experimento. As aplicações dos tratamentos foram realizadas com um pulverizador costal com pressão constante (mantida a CO 2 ) de 40 lb/pol 2, com volume de aplicação de 200 L/ha. Observou-se que, no trabalho de Controle de Plantas Daninhas em Pré-Emergência, os tratamentos com adjuvantes foram superiores aos tratamentos sem adjuvantes no controle das plantas daninhas que ocorreram no experimento: Ipomoea nil (corda-de- viola), Commelina benghalensis (trapoeraba) e Panicum maximum (capim-colonião) e foram seletivos à cultura da cana-de-açúcar. No trabalho de Controle de Plantas Daninhas em Pós-Emergência, os tratamentos com adjuvantes foram superiores aos tratamentos sem adjuvantes no controle das plantas daninhas I. nil, C. benghalensis, P. maximum e Bidens pilosa (picão-preto) e também foram seletivos à cultura, sendo que no quesito fitotoxicidade invisível detectada pelo aparelho fluorômetro, o adjuvante Oppa-BR-EC foi o mais seletivo à cultura em ambas as doses do herbicida Krismat. No trabalho de Erradicação da Soqueira de Cana-de-Açúcar, a adição de adjuvantes à calda herbicida, além de melhorar a eficácia dos tratamentos, acelerou o processo de morte das plantas; na menor dose do herbicida (glyphosato a 4,5 L p.c./ha) o tratamento que proporcionou o maior índice de dessecação foi com o adjuvante Oppa- BR-EC (1,00% v/v) e na maior... / Adjuvants are substances added to the formulation of crop protection products in order to improve the effectiveness of these products. The aim of this study was to evaluate the effectiveness of mineral oils as herbicide adjuvants used in the culture of cane sugar. The work was divided into three experiments focuses on weed control in pre- and post-emergence and eradication of cane sugar from the stump. The experimental design used in the experiments was randomized blocks with twenty treatments and four replications for each experiment. Applications of the treatments were performed with a knapsack sprayer, with constant pressure (maintained CO2) of 40 lb / in2, with application volume of 200 L / ha. It was observed that in the work of Weed Control in Pre-Emergency, treatments with adjuvants were higher than treatments without adjuvants in weed control that occurred in the experiment: Ipomoea nil (string-of- viola), Commelina benghalensis ( spiderwort) and Panicum maximum (guinea grass) and were selective for the cultivation of cane sugar. In the work of Weed Control in Post-Emergency, treatments with adjuvants were higher than treatments without adjuvants in the control of weeds I. nil, C. benghalensis, P. maximum and Bidens pilosa (beggartick) and were also highly selective culture, and in the question invisible phytotoxicity detected by the fluorometer apparatus, the Oppa-BR-EC adjuvant was the most selective culture at both doses of Krismat herbicide. At work Eradication of ratoon cane sugar, the addition of adjuvants to the herbicide spray, and improve the effectiveness of treatments, accelerated the death of plants; herbicide at the lowest dose (4.5 L glyphosato cp / ha) treatment resulted in the highest drying rate was with Oppa-US-EC adjuvant (1.00% v / v) and higher dose (6, 0 l / ha) all treatments were highly effective adjuvants and higher than the control without adjuvant
15

Eficácia de óleos minerais aplicados como adjuvantes auxiliando na selitividade de herbicidas na cultura de cana-de-açúcar /

Santos, Eigon Costa dos. January 2015 (has links)
Orientador: Fernando Tadeu de Carvalho / Banca: Sergio Luis de Carvalho / Banca: Marco Antonio de Souza Silva / Resumo: Os adjuvantes são substâncias adicionadas à formulação dos defensivos agrícolas com o intuito de melhorar a eficácia desses produtos. O objetivo do presente trabalho foi avaliar a eficácia de óleos minerais como adjuvantes de herbicidas utilizados na cultura da cana-de-açúcar. O trabalho foi dividido em três experimentos com focos em controle de plantas daninhas em pré e pós-emergência e em erradicação da soqueira de cana-açúcar. O delineamento experimental utilizado nos experimentos foi o de blocos ao acaso, com vinte tratamentos e quatro repetições para cada experimento. As aplicações dos tratamentos foram realizadas com um pulverizador costal com pressão constante (mantida a CO 2 ) de 40 lb/pol 2, com volume de aplicação de 200 L/ha. Observou-se que, no trabalho de Controle de Plantas Daninhas em Pré-Emergência, os tratamentos com adjuvantes foram superiores aos tratamentos sem adjuvantes no controle das plantas daninhas que ocorreram no experimento: Ipomoea nil (corda-de- viola), Commelina benghalensis (trapoeraba) e Panicum maximum (capim-colonião) e foram seletivos à cultura da cana-de-açúcar. No trabalho de Controle de Plantas Daninhas em Pós-Emergência, os tratamentos com adjuvantes foram superiores aos tratamentos sem adjuvantes no controle das plantas daninhas I. nil, C. benghalensis, P. maximum e Bidens pilosa (picão-preto) e também foram seletivos à cultura, sendo que no quesito fitotoxicidade invisível detectada pelo aparelho fluorômetro, o adjuvante Oppa-BR-EC foi o mais seletivo à cultura em ambas as doses do herbicida Krismat. No trabalho de Erradicação da Soqueira de Cana-de-Açúcar, a adição de adjuvantes à calda herbicida, além de melhorar a eficácia dos tratamentos, acelerou o processo de morte das plantas; na menor dose do herbicida (glyphosato a 4,5 L p.c./ha) o tratamento que proporcionou o maior índice de dessecação foi com o adjuvante Oppa- BR-EC (1,00% v/v) e na maior... / Abstract: Adjuvants are substances added to the formulation of crop protection products in order to improve the effectiveness of these products. The aim of this study was to evaluate the effectiveness of mineral oils as herbicide adjuvants used in the culture of cane sugar. The work was divided into three experiments focuses on weed control in pre- and post-emergence and eradication of cane sugar from the stump. The experimental design used in the experiments was randomized blocks with twenty treatments and four replications for each experiment. Applications of the treatments were performed with a knapsack sprayer, with constant pressure (maintained CO2) of 40 lb / in2, with application volume of 200 L / ha. It was observed that in the work of Weed Control in Pre-Emergency, treatments with adjuvants were higher than treatments without adjuvants in weed control that occurred in the experiment: Ipomoea nil (string-of- viola), Commelina benghalensis ( spiderwort) and Panicum maximum (guinea grass) and were selective for the cultivation of cane sugar. In the work of Weed Control in Post-Emergency, treatments with adjuvants were higher than treatments without adjuvants in the control of weeds I. nil, C. benghalensis, P. maximum and Bidens pilosa (beggartick) and were also highly selective culture, and in the question invisible phytotoxicity detected by the fluorometer apparatus, the Oppa-BR-EC adjuvant was the most selective culture at both doses of Krismat herbicide. At work Eradication of ratoon cane sugar, the addition of adjuvants to the herbicide spray, and improve the effectiveness of treatments, accelerated the death of plants; herbicide at the lowest dose (4.5 L glyphosato cp / ha) treatment resulted in the highest drying rate was with Oppa-US-EC adjuvant (1.00% v / v) and higher dose (6, 0 l / ha) all treatments were highly effective adjuvants and higher than the control without adjuvant / Mestre
16

Inferência espacial de clorofila a por redes neurais artificiais aplicadas a imagens multiespectrais e medidas tomadas "in situ" /

Ferreira, Monique Sacardo. January 2011 (has links)
Orientador: Maria de Lourdes Bueno Trindade Galo / Banca: Luciana de Resende Londe / Banca: Aluir Porfirio Dal Poz / Resumo: O conhecimento da distribuição espacial da concentração de componentes da água é de fundamental importância para inferir a respeito dos processos ecológicos que ocorrem num sistema hídrico sendo, entretanto, de difícil obtenção. Dentre as variáveis que merecem atenção no monitoramento de ambientes aquáticos, destaca-se a clorofila a, a qual é uma substância presente em algas responsáveis pela fotossíntese, organismos que constituem a base da cadeia alimentar nesses ambientes. Por se tratar de um pigmento fotossintetizante, a clorofila a apresenta a propriedade de interagir com a radiação eletromagnética, e dessa interação resultam diferentes processos, identificáveis por meio de sensores remotos. Assim sendo, a presente pesquisa se propôs a desenvolver um método de inferência da concentração de clorofila a utilizando Redes Neurais Artificiais (RNA). Utilizou-se como dados de entrada para a inferência combinações de bandas espectrais de uma imagem World View-2 e valores de concentração de clorofila a obtidos com um fluorômetro de campo, o qual possibilitou uma amostragem densa na área de estudos. A imagem multiespectral foi corrigida radiometricamente, eliminando efeitos de instrumentação e atmosféricos. Ainda, efetuou-se uma suavização espectral em cada uma das bandas e foi avaliado se esse tratamento na imagem possibilitaria... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The knowledge of the spatial distribution of water components concentrations is of fundamental importance to infer about the ecological processes that occur in an aquatic system, however, is difficult to obtain it. Among the variables that deserve attention in the monitoring of aquatic environments, cite the chlorophyll a, which is a substance of photosynthetic algae, organisms that are the basis of the food chain in these environments. Because it is a photosynthetic pigment, chlorophyll a has the property to interact with electromagnetic radiation, and it results in different processes, identifiable through remote sensing. Thus, this research intended to develop a chlorophyll a concentration inference method using Artificial Neural Networks (ANN). As input for the inference, it was used combinations of World View-2 spectral bands and chlorophyll a concentration values obtained with a field fluorometer, which allowed a dense sampling in the study area. The multispectral imagery was radiometrically corrected, eliminating the instrumentation and atmospheric effects. Still, it was performed a spectral smoothing in each of the spectral bands and evaluated whether this treatment would give... (Complete abstract click electronic access below) / Mestre
17

Avaliação da influência do reservatório do funil na qualidade da água do rio Paraíba do Sul / Evaluation of the influence of the funil reservoir on the quality of the Paraíba do Sul river water

Afranio Reis Rodrigues Primo 26 February 2007 (has links)
O rio Paraíba do Sul, após formar o reservatório do Funil, abastece cidades ribeirinhas e a cidade do Rio de Janeiro. A INB, uma empresa da área nuclear, está localizada na margem norte deste reservatório. Neste trabalho, Ag, Al, As, Ba, Cd, Co, Cr, Fe, Mn, Ni e Pb foram determinados por ICP OES em água e sedimentos em pontos a montante e a jusante do Funil e neste. Urânio, usando fluorimetria, também foi determinado em amostras coletadas a montante e a jusante do ponto de descarga de efluentes da INB, no ribeirão da Água Branca. O estudo não mostrou evidências que a INB está provocando impacto ambiental nesse ribeirão. As, Ni e Pb em todos os pontos de amostragem e Al, Cr e Fe na maioria desses pontos apresentaram concentrações em água acima do máximo permitido pela CONAMA 357. A maioria dos elementos apresentou concentrações nas amostras de água a montante do reservatório do Funil superiores às verficadas a jusante, para ambas as estações chuvosa e seca. Os sedimentos estão impactados por As, Cd, Cr e Pb em quase todos os pontos estudados. / The Paraiba do Sul River after forming the Funil Reservoir serves as the major source of potable water for downstream cities and for the city of Rio de Janeiro. INB, a company of the nuclear area, is located in the north margin of this reservoir. In the present study, Ag, Al, As, Ba, Cd, Co, Cr, Fe, Mn, Ni and Pb were determined by ICP OES in water and sediments samples at points upstream and downstream from Funil and in this one. Uranium, using fluorimetry, was also determined in samples collected upstream and downstream from the INB effluent discharge point at the Água Branca Creek. The study did not show evidences that INB is provoking environmental impact in this creek. As, Ni and Pb in all the sampling points and Al, C and Fe in most of those points exceeded the CONAMA 357 standards for water. Most of the elements presented concentration in the water samples at the points upstream from Funil reservoir higher than those downstream, for both rainy and dry seasons. Sediments are impacted by As, Cd, Cr and Pb in almost all the studied points.
18

[en] CHLOROPHYLL A DETERMINATION IN MARINE WATER BY FLUORESCENCE / [pt] MEDIDAS DA CLOROFILA A EM ÁGUAS MARINHAS POR FLUORESCÊNCIA

ANA GABRIELA BARBOSA MATOS 18 December 2001 (has links)
[pt] A clorofila a é um composto-chave no processo de absorção e aproveitamento da energia luminosa na fotossíntese. Monitorar a fluorescência da clorofila a para obter informações do aparato fotossintético de produção de energia é uma abordagem atraente porque a fluorescência á percebida externamente às células, podendo ser detectada sem destruir sua fonte. Estudos anteriores realizados pelo Laboratório de Hidrobiologia (UFRJ) e pelo Laboratório de Monitoramento Ambiental Remoto (LabMAR) (PUC-Rio) em águas marinhas indicaram a existência de uma relação linear entre os valores absolutos obtidos pelo Laboratório de Hidrobiologia para a concentração da clorofila a e os valores relativos obtidos pelo LabMAR para a sua fluorescência. Este resultado motivou os dois laboratórios a obter valores absolutos para a concentração da clorofila a em águas marinhas, a partir da medida de sua fluorescência, com a maior confiabilidade possível para, então, relacioná-los aos valores relativos fornecidos pelo LIDAR-PUC. Neste sentido, a implantação de um programa de controle de qualidade no Laboratório de Hidrobiologia indicou que este laboratório encontra-se em condições de obter valores confiáveis para a concentração da clorofila a em amostras de águas marinhas através da fluorimetria. No entanto, uma avaliação rigorosa da relação entre a intensidade da fluorescência da clorofila a (normalizada pela intensidade da emissão do espalhamento Raman da água) e o respectivo valor confiável para a concentração da clorofila a se faz necessária. / [en] Chlorophyll a is a key-compound in the process of light absorption in the photosynthesis. Monitor the chlorophyll a fluorescence to obtain information about the photosynthetic apparatus of energy production is attractive because the chlorophyll a fluorescence could be detected without destruction of the source. Studies performed by the Laboratório de Hidrobiologia (UFRJ) and by the Laboratório de Monitoramento Ambiental Remoto (LabMAR) (PUC-Rio) in marine water samples indicated a linear relation between the absolute values obtained by the former for the chlorophyll a concentration and the relative values obtained by the latter for the chlorophyll a fluorescence. This result motivated both laboratories to obtain absolute values for the chlorophyll a concentration, in marine water samples, as confident as possible and, then, relate these values to the relative values generated by the LIDAR-PUC. In this way, the introduction of a quality control program in the Laboratório de Hidrobiologia indicated that this laboratory is able to analyse marine water samples and to obtain confident values for the chlorophyll a concentration by fluorimetry. However, a more rigorous evaluation of the relation between the chlorophyll a fluorescence and the respective confident value for the chlorophyll a concentration is still necessary.
19

Sistemas optoeletrônicos portáteis para detecção de gases, oxigênio dissolvido e de metais pesados aplicados no controle ambiental. / Portable environmental monitoring systems, dissolved oxygen, heavy metals, colorimetric, fluorimetry.

Braga, Mauro Sergio 02 August 2016 (has links)
O monitoramento ambiental de forma contínua e em tempo real são desafios da realidade atual dos grandes centros urbanos, com a finalidade de prevenir desastres ambientais que possam pôr em perigo a saúde dos seres humanos e a existência de sistemas biológicos. Na presente tese foram propostos e desenvolvidos sistemas optoeletrônicos portáteis aplicados na detecção de O2, OD e íons de metais pesados, visando seu emprego no monitoramento de sistemas hidrológicos como mares, rios, lagos e lençóis freáticos. A definição final da estrutura do sistema portátil foi atingida após o desenvolvimento sistemático de diferentes ensaios experimentais. Primeiramente, foram estudadas e analisadas matrizes hospedeiras em estado sólido que fossem capazes de hospedar sistemas moleculares corantes sensíveis a certas substâncias específicas. A seguir, foi proposta e executada a integração direta dos filmes hospedeiros, dopados com moléculas corantes ativas, diretamente na superfície ativa de dispositivos fotodetectores para detecção de O2 e OD. Os resultados obtidos com estes sistemas que integram o detector e o filme ativo mostraram o mesmo nível de desempenho aos espectrômetros de bancada. Finalmente, de posse destes resultados, foi projetado e desenvolvido um sistema colorimétrico e fluorimétrico portátil e embarcado em uma placa de aquisição (myRIO-1900) da National Instruments, aplicado na detecção e classificação de íons metálicos. Destaque principal é outorgado à aplicação do colorímetro que, juntamente com o processamento de sinais e análises de padrões, utilizando o método de discriminante de Fisher, permitiu obter resultados excelentes na detecção e classificação dos íons de Pb2+, Cd2+, Zn2+, Cu2+, Fe3+ e Ni2+, com os mesmos níveis de desempenho que os obtidos a partir de espectrômetros de bancada de elevada resolução espectral. O sistema portátil desenvolvido sugere sua aplicação no controle ambiental in situ e em tempo real, podendo ser integrado em uma rede de sensores que possam fornecer dados de maneira contínua e receber comandos de centros de controle de monitoramento ambiental. No entanto, seria necessária a formulação de algoritmos eficientes no processo de mineração de dados da rede de sensores. / The continuous and in real time environmental monitoring are challenges of the current days of large urban centers, with the aim of preventing environmental disasters that could endanger human health and the existence of biological systems. In this thesis we have proposed and developed portable optoelectronic systems applied to the detection of O2, OD and heavy metal ions, aiming its use in monitoring hydrological systems such as oceans, rivers, lakes and groundwater. The final definition of the portable system structure was achieved after the systematic development of different experimental assays. First, host matrices were studied and analyzed in solid state which were able to host dye molecular systems sensitive to certain substances. Then, we proposed and executed the direct integration of the host film, doped with active dye molecules directly on the active surface of photodetector devices to the detection of O2 and OD. The results obtained with these systems that integrate the detector and the active film showed the same level of performance than those of benchtop spectrometers. Finally, with these results, we designed and developed a colorimetric and fluorimetric portable system with an embedded acquisition board (myRIO-1900) from National Instruments, applied to the detection and classification of metal ions. Main focus is given to the application of the colorimeter which, along with the signal processing and pattern analysis using the Fisher discriminant method, allowed to obtain excellent results in the detection and classification of Pb2+, Cd2+, Zn2+, Cu2+, Fe3+ and Ni2+ ions, with the same level of performance related to those obtained from high spectral resolution benchtop spectrometers. The portable system developed in the present thesis suggests its application in environmental control in situ and in real time, so that it can be integrated in a network of sensors that may provide continuous data and receive commands from environmental monitoring control center; nevertheless, requiring for that the development of efficient algorithms in data mining process of the sensor network.
20

Sistemas optoeletrônicos portáteis para detecção de gases, oxigênio dissolvido e de metais pesados aplicados no controle ambiental. / Portable environmental monitoring systems, dissolved oxygen, heavy metals, colorimetric, fluorimetry.

Mauro Sergio Braga 02 August 2016 (has links)
O monitoramento ambiental de forma contínua e em tempo real são desafios da realidade atual dos grandes centros urbanos, com a finalidade de prevenir desastres ambientais que possam pôr em perigo a saúde dos seres humanos e a existência de sistemas biológicos. Na presente tese foram propostos e desenvolvidos sistemas optoeletrônicos portáteis aplicados na detecção de O2, OD e íons de metais pesados, visando seu emprego no monitoramento de sistemas hidrológicos como mares, rios, lagos e lençóis freáticos. A definição final da estrutura do sistema portátil foi atingida após o desenvolvimento sistemático de diferentes ensaios experimentais. Primeiramente, foram estudadas e analisadas matrizes hospedeiras em estado sólido que fossem capazes de hospedar sistemas moleculares corantes sensíveis a certas substâncias específicas. A seguir, foi proposta e executada a integração direta dos filmes hospedeiros, dopados com moléculas corantes ativas, diretamente na superfície ativa de dispositivos fotodetectores para detecção de O2 e OD. Os resultados obtidos com estes sistemas que integram o detector e o filme ativo mostraram o mesmo nível de desempenho aos espectrômetros de bancada. Finalmente, de posse destes resultados, foi projetado e desenvolvido um sistema colorimétrico e fluorimétrico portátil e embarcado em uma placa de aquisição (myRIO-1900) da National Instruments, aplicado na detecção e classificação de íons metálicos. Destaque principal é outorgado à aplicação do colorímetro que, juntamente com o processamento de sinais e análises de padrões, utilizando o método de discriminante de Fisher, permitiu obter resultados excelentes na detecção e classificação dos íons de Pb2+, Cd2+, Zn2+, Cu2+, Fe3+ e Ni2+, com os mesmos níveis de desempenho que os obtidos a partir de espectrômetros de bancada de elevada resolução espectral. O sistema portátil desenvolvido sugere sua aplicação no controle ambiental in situ e em tempo real, podendo ser integrado em uma rede de sensores que possam fornecer dados de maneira contínua e receber comandos de centros de controle de monitoramento ambiental. No entanto, seria necessária a formulação de algoritmos eficientes no processo de mineração de dados da rede de sensores. / The continuous and in real time environmental monitoring are challenges of the current days of large urban centers, with the aim of preventing environmental disasters that could endanger human health and the existence of biological systems. In this thesis we have proposed and developed portable optoelectronic systems applied to the detection of O2, OD and heavy metal ions, aiming its use in monitoring hydrological systems such as oceans, rivers, lakes and groundwater. The final definition of the portable system structure was achieved after the systematic development of different experimental assays. First, host matrices were studied and analyzed in solid state which were able to host dye molecular systems sensitive to certain substances. Then, we proposed and executed the direct integration of the host film, doped with active dye molecules directly on the active surface of photodetector devices to the detection of O2 and OD. The results obtained with these systems that integrate the detector and the active film showed the same level of performance than those of benchtop spectrometers. Finally, with these results, we designed and developed a colorimetric and fluorimetric portable system with an embedded acquisition board (myRIO-1900) from National Instruments, applied to the detection and classification of metal ions. Main focus is given to the application of the colorimeter which, along with the signal processing and pattern analysis using the Fisher discriminant method, allowed to obtain excellent results in the detection and classification of Pb2+, Cd2+, Zn2+, Cu2+, Fe3+ and Ni2+ ions, with the same level of performance related to those obtained from high spectral resolution benchtop spectrometers. The portable system developed in the present thesis suggests its application in environmental control in situ and in real time, so that it can be integrated in a network of sensors that may provide continuous data and receive commands from environmental monitoring control center; nevertheless, requiring for that the development of efficient algorithms in data mining process of the sensor network.

Page generated in 0.0777 seconds