• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 2
  • 1
  • Tagged with
  • 14
  • 14
  • 12
  • 12
  • 12
  • 11
  • 11
  • 11
  • 11
  • 11
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Usos do território e políticas de ciência, tecnologia e inovação em saúde: uma abordagem a partir da circularidade produtiva do radiofármaco FDG-18F para estudos PET-CT na Argentina e no Brasil / Uses of territory and science, technology and health innovation policies:a perspective on the productive circularity of the radiopharmaceutical FDG-18F for PET-CT studies in Argentina and Brazil

Iozzi, Fabíola Lana 18 February 2014 (has links)
Argentina e Brasil apresentam, cada um com suas particularidades, situações deficitárias no que diz respeito à base produtiva de alta intensidadetecnológica. Nesse amplo contexto, mostram-se de forte relevância políticas públicas de ciência, tecnologia e inovação voltadas para o fortalecimento e aprimoramento das áreas de produção e pesquisa nacionais em campos estratégicos. Por conformar um ramo fortemente demandante e dependente de produtos e serviços com intenso conteúdo tecnológico e ser um dos pilares do sistema de proteção social, o campo da saúde ganha destaque. Com isso, aparece como central para as políticas públicas nacionais dos países subdesenvolvidos, tendo em vista a importância de alcançarem maiores graus de autonomia frente aos oligopólios mundiais que dominam a produção de medicamentos e equipamentos para a saúde. É nesse conjunto de circunstâncias que se insere a proposta do presente trabalho, cujo objetivo é analisar umcircuito espacial produtivo e seus respectivos círculos de cooperação (SANTOS, 1986) que envolvem um serviço de alta densidade tecnológica na área da saúde. O recorte mais específico é a circularidade produtiva do radiofármaco fluordesoxiglucose (FDG-18F) para estudos em equipamento de tomografia por emissão de pósitrons (PET-CT) na Argentina e no Brasil. Para alcançar esse objetivo, além de pesquisa bibliográfica sobre o tema, empreendeu-se uma análise das políticas de ciência, tecnologia e inovação em saúde nos dois países. Destaca-se a realização de entrevistas com atores-chaves de várias instituições argentinas e brasileiras, abarcando representantes dos mais diversos segmentos envolvidos no circuito espacial produtivo estudado. O conjunto analítico explorado possibilitou o encontro de relevantes similitudes entre o funcionamento sistêmico dos elementos em questão nos dois países analisados, fundamentalmente no que concerne à lógica de atuação de setores privados na oferta e disponibilização de equipamentos e na prestação de serviços sofisticados de diagnóstico por imagem, como o caso do PET-CT. As estratégias de incorporação da tomografia computadorizada por emissão de pósitrons nos sistemas de saúde brasileiro e argentino são exemplos significativos, na área da saúde, de como as políticas do Estado e das empresas têm articulado os lugares para promover circuitos espaciais produtivos e círculos de cooperação que, todavia, nem sempre respondem aos princípios de universalização da saúde / Argentina and Brazil are found to be lacking in terms of a production base of high intensity technology.In this broad context, public policies on science, technology and innovation aimed at strengthening and improving national production and research in strategic fields are highly significant.Constituting a segment that is both heavily demanding and dependent on high technological content products and services and as one of the pillars of the social protection system, the field of health care is of particular importance.Thus it appears as central to the national public policies of developing countries, bearing in mind the importance of achieving greater degrees of autonomy from the global oligopolies that dominate the production of drugs and health care equipment.It is within this set of circumstances that the proposal for this study is placed, with the aim of analysing a productive spatial circuit and its respective circles of cooperation (Milton Santos, 1986) involved in the service of technological high density in the area of health.The most specific example is the productive circularity of the radiopharmaceutical fluorodeoxyglucose (FDG-18F) for studies in positron emission tomography equipment (PET-CT) in Argentina and Brazil.To achieve this aim, as well as a bibliographic study on the topic, a review was conducted into the science, technology and innovation policies in health in both countries.This featured interviews with key players from several Argentinian and Brazilian institutions, encompassing representatives from the most diverse segments involved in the productive spatial circuit under investigation. The analytical set explored enabled the finding of significant similarities between the systemic functioning of the elements in question in both countries, fundamentally as regards the role played by the private sector in the supply of equipment and the provision of sophisticated diagnostic imaging services, such as PET-CT.Strategies to incorporate PETCT scans into the Brazilian and Argentinian health systems is a significant example of how the policies of the State and of private companies have underpinned the places to promote productive spatial circuits and circles of cooperation that do not always answer to the principles of universalized health care
12

Nova técnica para pesquisa de viabilidade miocárdica com 18F-fluoro-desoxi-glicose utilizando dieta restrita em carboidratos: estudo comparativo com o clamp hiperinsulínico euglicêmico / New method in myocardial viability detection with 18F-fluoro-desoxi-glucose using a low-carbohydrate diet: a comparative study with euglycemic hyperinsulinemic clamp

Rodrigues Filho, Filadelfo 26 September 2008 (has links)
INTRODUÇÃO: Em pacientes com infarto do miocárdio (IM) e disfunção cardíaca, a evidência de viabilidade miocárdica é primordial, e o exame tomográfico por emissão de pósitrons com 18F-fluoro-desoxi-glicose (18FDG-PET) é o padrão-ouro para essa identificação. Existe preferência, na literatura, pela realização do clamp hiperínsulínico euglicêmico (CLAMP) antes da injeção de 18FDG para estimular todo o miocárdio a consumir glicose (GLI), garantindo assim a sua captação pelas áreas de miocárdio hibernado (MH). No entanto, essa técnica é trabalhosa, além do risco de hipoglicemia durante a realização. Desenvolvemos uma nova técnica na qual o paciente é submetido a uma dieta restrita em carboidratos (DIETA) por 24 horas antes do exame, sem a necessidade de CLAMP, com o objetivo de diminuir os níveis de insulina e aumentar ácidos graxos livres (AGL), estimulando o miocárdio normal a consumir AGL, e não GLI. A área de MH, porém, não consegue realizar o metabolismo oxidativo de AGL, mantendo o consumo de GLI. OBJETIVOS: comparar o PET após DIETA (PET-DIETA) com o PET após CLAMP (PET-CLAMP), para a pesquisa de viabilidade miocárdica. MÉTODOS: Trinta pacientes com IM prévio e hipocinesia na área infartada foram submetidos à cintilografia de perfusão miocárdica com 99mTc-sestamibi (MIBI), PET-CLAMP e PET-DIETA. A DIETA limitava-se a 15-20g de carboidratos por dia. Os exames foram submetidos à análise visual e classificados por escores (0 a 4). Foram consideras áreas de mismatch (MH) aquelas com hipoperfusão ao MIBI e captação presente no PET-CLAMP ou no PET-DIETA, em um modelo de 17 segmentos, além da análise por parede, território arterial e por paciente. A análise por segmentos foi realizada ainda dividindo-se os pacientes em diabéticos (DM) e não diabéticos (NDM). O PET-DIETA também foi submetido à análise automática (por percentual de captação) RESULTADOS: Durante o CLAMP, seis (20%) pacientes apresentaram hipoglicemia. Nenhum paciente apresentou hipoglicemia após a DIETA. Houve concordância na análise visual do PET-CLAMP e PET-DIETA para detecção de áreas de mismatch em 94,5% dos segmentos analisados, com um índice kappa de 0,78 (concordância substancial). Essa concordância se manteve na análise por parede (0,80), território arterial (k=0,79) e por paciente (0,79). Quando dividimos os pacientes em NDM (22) e DM (8), encontramos k=0,78 para o subgrupo NDM e 0,70 para o subgrupo DM. A análise automática para o PET-DIETA evidenciou, quando comparada com a análise visual do PET-CLAMP, uma concordância moderada, com índice kappa de 0,50 para análise por segmento, 0,54 por parede, 0,60 por território arterial e 0,48 por paciente. CONCLUSÕES: Concluímos assim que o exame de PET-DIETA apresenta uma excelente concordância para detecção de áreas de mismatch com o PET-CLAMP, ambos em conjunto com a análise do MIBI, possivelmente com mais segurança para o paciente. Essa concordância se mantém quando avaliamos os subgrupos de DM e NDM / BACKGROUND: In patients with myocardial infarction and left ventricular dysfunction, the evidence of myocardial viability has important clinical implications. Positron emission tomography (PET) using 18F-fluoro-desoxi-glucose (18FDG) is considered the gold standard for viability detection. The euglycemic hyperinsulinemic clamping (CLAMP) before 18FDG injection stimulates uptake of both glucose and 18FDG in the myocardium, including areas of hibernating myocardium (MH), and it is the most used protocol. However, this imaging protocol has an increased risk for hypoglycemia and is relatively time-consuming. We developed a new protocol using a 24 hours low-carbohydrate diet (DIET), aiming to reduce insulin levels and increase free fatty acids (FFA). This protocol stimulates the normal myocardium to use FFA, not glucose, but the area of hibernating myocardium (viable area) may not use oxidative metabolism with FFA, keeping glucose uptake and becoming a hot spot at PET images. The aim of this study was to compare both techniques by segments, regions, vascular territories and patients. METHODS: Thirty patients with previous myocardial infarction and left ventricular dysfunction were studied. All of them underwent into a SPECT perfusion scan with 99mTc-sestamibi and two 18FDG PET studies to asses myocardial viability, one with CLAMP (PET-CLAMP) and another using a 24 hours low-carbohydrate diet (PET-DIET). For the analysis, the myocardium was divided into 17 segments, 5 regions and 3 vascular territories. A visual and an automatic semi-quantitative analysis (only for PET-DIET) were carried out according to the following score indicating radiotracer uptake: 0 = normal to 4 = absent. Myocardial viability was defined as the presence of normal or mildly reduced FDG uptake in an area with reduced perfusion (99mTc-sestamibi uptake). We also performed subgroup analyses in diabetes (DM) and non-diabetic patients (NDM). RESULTS: While using CLAMP protocol, six (20%) patients had hypoglycemia. None of the patients had hypoglycemia after using DIET. High agreement rates were observed with visual analysis in comparing mismatch areas (kappa=0,78 substancial concordance). Similar rates were find in regions (0,80), vascular territories (0,79) and patient (0,79) analysis. In subgroup analysis, DM (8) presented with kappa=0,70 and NDM (22) with kappa=0,78. Upon analysis, the automatic method for PET-DIET showed moderate agreement when compared with PET-CLAMP visual analysis by segments (Kappa=0,50), regions (0,54), vascular territories (0,60) and patient (0,48). CONCLUSIONS: This has led to the suggestion that PET-DIET study proved an excellent agreement in detects mismatch areas assessed by PET-CLAMP, with probably more safety. The same results occurs in the in diabetes and non-diabetic patients subgroups
13

Usos do território e políticas de ciência, tecnologia e inovação em saúde: uma abordagem a partir da circularidade produtiva do radiofármaco FDG-18F para estudos PET-CT na Argentina e no Brasil / Uses of territory and science, technology and health innovation policies:a perspective on the productive circularity of the radiopharmaceutical FDG-18F for PET-CT studies in Argentina and Brazil

Fabíola Lana Iozzi 18 February 2014 (has links)
Argentina e Brasil apresentam, cada um com suas particularidades, situações deficitárias no que diz respeito à base produtiva de alta intensidadetecnológica. Nesse amplo contexto, mostram-se de forte relevância políticas públicas de ciência, tecnologia e inovação voltadas para o fortalecimento e aprimoramento das áreas de produção e pesquisa nacionais em campos estratégicos. Por conformar um ramo fortemente demandante e dependente de produtos e serviços com intenso conteúdo tecnológico e ser um dos pilares do sistema de proteção social, o campo da saúde ganha destaque. Com isso, aparece como central para as políticas públicas nacionais dos países subdesenvolvidos, tendo em vista a importância de alcançarem maiores graus de autonomia frente aos oligopólios mundiais que dominam a produção de medicamentos e equipamentos para a saúde. É nesse conjunto de circunstâncias que se insere a proposta do presente trabalho, cujo objetivo é analisar umcircuito espacial produtivo e seus respectivos círculos de cooperação (SANTOS, 1986) que envolvem um serviço de alta densidade tecnológica na área da saúde. O recorte mais específico é a circularidade produtiva do radiofármaco fluordesoxiglucose (FDG-18F) para estudos em equipamento de tomografia por emissão de pósitrons (PET-CT) na Argentina e no Brasil. Para alcançar esse objetivo, além de pesquisa bibliográfica sobre o tema, empreendeu-se uma análise das políticas de ciência, tecnologia e inovação em saúde nos dois países. Destaca-se a realização de entrevistas com atores-chaves de várias instituições argentinas e brasileiras, abarcando representantes dos mais diversos segmentos envolvidos no circuito espacial produtivo estudado. O conjunto analítico explorado possibilitou o encontro de relevantes similitudes entre o funcionamento sistêmico dos elementos em questão nos dois países analisados, fundamentalmente no que concerne à lógica de atuação de setores privados na oferta e disponibilização de equipamentos e na prestação de serviços sofisticados de diagnóstico por imagem, como o caso do PET-CT. As estratégias de incorporação da tomografia computadorizada por emissão de pósitrons nos sistemas de saúde brasileiro e argentino são exemplos significativos, na área da saúde, de como as políticas do Estado e das empresas têm articulado os lugares para promover circuitos espaciais produtivos e círculos de cooperação que, todavia, nem sempre respondem aos princípios de universalização da saúde / Argentina and Brazil are found to be lacking in terms of a production base of high intensity technology.In this broad context, public policies on science, technology and innovation aimed at strengthening and improving national production and research in strategic fields are highly significant.Constituting a segment that is both heavily demanding and dependent on high technological content products and services and as one of the pillars of the social protection system, the field of health care is of particular importance.Thus it appears as central to the national public policies of developing countries, bearing in mind the importance of achieving greater degrees of autonomy from the global oligopolies that dominate the production of drugs and health care equipment.It is within this set of circumstances that the proposal for this study is placed, with the aim of analysing a productive spatial circuit and its respective circles of cooperation (Milton Santos, 1986) involved in the service of technological high density in the area of health.The most specific example is the productive circularity of the radiopharmaceutical fluorodeoxyglucose (FDG-18F) for studies in positron emission tomography equipment (PET-CT) in Argentina and Brazil.To achieve this aim, as well as a bibliographic study on the topic, a review was conducted into the science, technology and innovation policies in health in both countries.This featured interviews with key players from several Argentinian and Brazilian institutions, encompassing representatives from the most diverse segments involved in the productive spatial circuit under investigation. The analytical set explored enabled the finding of significant similarities between the systemic functioning of the elements in question in both countries, fundamentally as regards the role played by the private sector in the supply of equipment and the provision of sophisticated diagnostic imaging services, such as PET-CT.Strategies to incorporate PETCT scans into the Brazilian and Argentinian health systems is a significant example of how the policies of the State and of private companies have underpinned the places to promote productive spatial circuits and circles of cooperation that do not always answer to the principles of universalized health care
14

Nova técnica para pesquisa de viabilidade miocárdica com 18F-fluoro-desoxi-glicose utilizando dieta restrita em carboidratos: estudo comparativo com o clamp hiperinsulínico euglicêmico / New method in myocardial viability detection with 18F-fluoro-desoxi-glucose using a low-carbohydrate diet: a comparative study with euglycemic hyperinsulinemic clamp

Filadelfo Rodrigues Filho 26 September 2008 (has links)
INTRODUÇÃO: Em pacientes com infarto do miocárdio (IM) e disfunção cardíaca, a evidência de viabilidade miocárdica é primordial, e o exame tomográfico por emissão de pósitrons com 18F-fluoro-desoxi-glicose (18FDG-PET) é o padrão-ouro para essa identificação. Existe preferência, na literatura, pela realização do clamp hiperínsulínico euglicêmico (CLAMP) antes da injeção de 18FDG para estimular todo o miocárdio a consumir glicose (GLI), garantindo assim a sua captação pelas áreas de miocárdio hibernado (MH). No entanto, essa técnica é trabalhosa, além do risco de hipoglicemia durante a realização. Desenvolvemos uma nova técnica na qual o paciente é submetido a uma dieta restrita em carboidratos (DIETA) por 24 horas antes do exame, sem a necessidade de CLAMP, com o objetivo de diminuir os níveis de insulina e aumentar ácidos graxos livres (AGL), estimulando o miocárdio normal a consumir AGL, e não GLI. A área de MH, porém, não consegue realizar o metabolismo oxidativo de AGL, mantendo o consumo de GLI. OBJETIVOS: comparar o PET após DIETA (PET-DIETA) com o PET após CLAMP (PET-CLAMP), para a pesquisa de viabilidade miocárdica. MÉTODOS: Trinta pacientes com IM prévio e hipocinesia na área infartada foram submetidos à cintilografia de perfusão miocárdica com 99mTc-sestamibi (MIBI), PET-CLAMP e PET-DIETA. A DIETA limitava-se a 15-20g de carboidratos por dia. Os exames foram submetidos à análise visual e classificados por escores (0 a 4). Foram consideras áreas de mismatch (MH) aquelas com hipoperfusão ao MIBI e captação presente no PET-CLAMP ou no PET-DIETA, em um modelo de 17 segmentos, além da análise por parede, território arterial e por paciente. A análise por segmentos foi realizada ainda dividindo-se os pacientes em diabéticos (DM) e não diabéticos (NDM). O PET-DIETA também foi submetido à análise automática (por percentual de captação) RESULTADOS: Durante o CLAMP, seis (20%) pacientes apresentaram hipoglicemia. Nenhum paciente apresentou hipoglicemia após a DIETA. Houve concordância na análise visual do PET-CLAMP e PET-DIETA para detecção de áreas de mismatch em 94,5% dos segmentos analisados, com um índice kappa de 0,78 (concordância substancial). Essa concordância se manteve na análise por parede (0,80), território arterial (k=0,79) e por paciente (0,79). Quando dividimos os pacientes em NDM (22) e DM (8), encontramos k=0,78 para o subgrupo NDM e 0,70 para o subgrupo DM. A análise automática para o PET-DIETA evidenciou, quando comparada com a análise visual do PET-CLAMP, uma concordância moderada, com índice kappa de 0,50 para análise por segmento, 0,54 por parede, 0,60 por território arterial e 0,48 por paciente. CONCLUSÕES: Concluímos assim que o exame de PET-DIETA apresenta uma excelente concordância para detecção de áreas de mismatch com o PET-CLAMP, ambos em conjunto com a análise do MIBI, possivelmente com mais segurança para o paciente. Essa concordância se mantém quando avaliamos os subgrupos de DM e NDM / BACKGROUND: In patients with myocardial infarction and left ventricular dysfunction, the evidence of myocardial viability has important clinical implications. Positron emission tomography (PET) using 18F-fluoro-desoxi-glucose (18FDG) is considered the gold standard for viability detection. The euglycemic hyperinsulinemic clamping (CLAMP) before 18FDG injection stimulates uptake of both glucose and 18FDG in the myocardium, including areas of hibernating myocardium (MH), and it is the most used protocol. However, this imaging protocol has an increased risk for hypoglycemia and is relatively time-consuming. We developed a new protocol using a 24 hours low-carbohydrate diet (DIET), aiming to reduce insulin levels and increase free fatty acids (FFA). This protocol stimulates the normal myocardium to use FFA, not glucose, but the area of hibernating myocardium (viable area) may not use oxidative metabolism with FFA, keeping glucose uptake and becoming a hot spot at PET images. The aim of this study was to compare both techniques by segments, regions, vascular territories and patients. METHODS: Thirty patients with previous myocardial infarction and left ventricular dysfunction were studied. All of them underwent into a SPECT perfusion scan with 99mTc-sestamibi and two 18FDG PET studies to asses myocardial viability, one with CLAMP (PET-CLAMP) and another using a 24 hours low-carbohydrate diet (PET-DIET). For the analysis, the myocardium was divided into 17 segments, 5 regions and 3 vascular territories. A visual and an automatic semi-quantitative analysis (only for PET-DIET) were carried out according to the following score indicating radiotracer uptake: 0 = normal to 4 = absent. Myocardial viability was defined as the presence of normal or mildly reduced FDG uptake in an area with reduced perfusion (99mTc-sestamibi uptake). We also performed subgroup analyses in diabetes (DM) and non-diabetic patients (NDM). RESULTS: While using CLAMP protocol, six (20%) patients had hypoglycemia. None of the patients had hypoglycemia after using DIET. High agreement rates were observed with visual analysis in comparing mismatch areas (kappa=0,78 substancial concordance). Similar rates were find in regions (0,80), vascular territories (0,79) and patient (0,79) analysis. In subgroup analysis, DM (8) presented with kappa=0,70 and NDM (22) with kappa=0,78. Upon analysis, the automatic method for PET-DIET showed moderate agreement when compared with PET-CLAMP visual analysis by segments (Kappa=0,50), regions (0,54), vascular territories (0,60) and patient (0,48). CONCLUSIONS: This has led to the suggestion that PET-DIET study proved an excellent agreement in detects mismatch areas assessed by PET-CLAMP, with probably more safety. The same results occurs in the in diabetes and non-diabetic patients subgroups

Page generated in 0.0402 seconds