• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 9
  • 7
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Métodos para otimização de abertura dinâmica da nova fonte de luz síncrotron brasileira - Sirius / Methods for optmisation of the dynamic aperture of the new Brazilian synchrotron light source

Marcondes, Rafael José França, 1987- 03 August 2012 (has links)
Orientador: Eduardo Granado Monteiro da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-19T18:24:03Z (GMT). No. of bitstreams: 1 Marcondes_RafaelJoseFranca_M.pdf: 4781078 bytes, checksum: 963ca375d793021d73e27eaf311966c2 (MD5) Previous issue date: 2012 / Resumo: Um novo anel de armazenamento de elétrons está sendo projetado para a produção de luz síncrotron de alto brilho no Laboratório Nacional de Luz Síncrotron (LNLS), em Campinas. Para atingir um alto brilho, requer-se uma forte focalização do feixe, levando a fortes não-linearidades dos campos magnéticos, o que limita a região de estabilidade do movimento dos elétrons. Neste trabalho, estudamos a dinâmica destas partículas no anel e aplicamos métodos para a otimização da abertura dinâmica / Abstract: A new electron storage ring, Sirius, is being designed for the production of high brightness synchrotron light at the Brazilian Synchrotron Light Laboratory (LNLS), in Campinas. To achieve high brightness, strong focusing of the beam is required, leading to strong non-linearities in the magnetic elds, which limit the region of stable motion of the electrons. In this work we study the dynamics of these particles in the ring and apply methods for the optimisation of the dynamic aperture / Mestrado / Mestre em Física
2

Desenvolvimento de uma fonte luminosa baseada em lâmpadas halógenas para aplicações na fotobiologia e fotomedicina / Development of a light source based in halogen lamps for applications in the photobiology and photomedicine.

Fonzi, Wagner 15 August 2008 (has links)
Este projeto teve como finalidade construir uma fonte de luz baseada em lâmpadas halógenas que apresentasse características técnicas adequadas para aplicações em fotobiologia e fotomedicina, versátil e comercialmente viável. Foram analisadas as características de diferentes lâmpadas halógenas e realizados os experimentos com duas lâmpadas escolhidas, das quais utilizamos a lâmpada de menor divergência luminosa. Foi analisado também o material do corpo da fonte, com relação a características de aquecimento e peso, sendo escolhido um corpo de alumínio produzido industrialmente. Foram avaliadas as características ópticas das lentes, sendo escolhidas as lentes de vidro utilizadas em retroprojetores. Foram analisados os materiais e a construção de filtros térmicos para diminuir o aquecimento do objeto sob irradiação, sendo que escolhemos construir um filtro térmico próprio, que utiliza a água como absorvedor de calor. Medimos e avaliamos as características: espectrais, térmicas, a potência radiante (irradiância) e sua distribuição espacial de três protótipos, onde cada um recebeu modificações de modo a torná-los mais adequados para aplicações na fotoquimeoterapia. Foram também realizados testes preliminares de fotocitotoxicidade do protótipo final com o composto fotossensibilizador de nome comercial Photogem® aplicado em células tumorais de adenocarcinoma de colo retal humano (HT29), cujo resultado foi a ativação do composto fotossensibilizador e indução da morte celular. / The aim of this work was to produce a light source based in halogen lamps. This source should have appropriated technical characteristic for application in photobiology and photomedicine, it has easy operation and be commercially viable. The characteristics of different halogen lamps were evaluated and the lamp of smaller luminous divergence was chosen. We also have evaluated the material of the source holder, especially heating characteristics and weight; finally we chose an aluminum holder. Then, the lenses optical characteristics were studied, and we decided that the glass lenses used in projectors were the best. The materials and the construction of thermal filters were evaluated in order to reduce the heating of the object under irradiation, and we preferred to construct a thermal filter, that uses water as an heat absorber. The spectral and thermal characteristics, the radiant power (irradiance) and its space distribution of three prototypes were measured and evaluated, each one received modifications to become more appropriated to applications in photochemotherapy. We also made preliminaries tests of photocytotoxicity and the final prototype was used with the photosensitizer (Photogem®) in human colon carcinoma cell lines HT-29, resulting in the photosensitizer activation, that induced cellular death.
3

Avaliação da efetividade da fotoativação de dois materiais resinosos com diferentes fontes de luz, por meio da microdureza Knoop, resistência à compressão, resistência flexural e caracterização dos materiais / Evaluation of the effect of the light source on the photo polymerization of two resin material by the Knoop microhardness, compressive strength, flexural strength and material characterization

Cecy Martins Silva 15 September 2006 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / O objetivo deste trabalho foi avaliar o efeito de um diodo emissor de luz (LED) Smart Lite PS (Dentsply) e da lâmpada halógena convencional Curing Light XL 3000 (3M) na efetividade de polimerização do compômero Dyract Ap (Dentsply) e da resina composta TPH Spectrum (Dentsply) por meio de testes de microdureza Knoop, resistência à compressão e resistência flexural e caracterização dos materiais. Foram confeccionadas 100 amostras e divididas em 12 grupos de acordo com o teste aplicado, a luz de polimerização e o material utilizado. A lâmpada halógena convencional selecionada, Curing Light XL 3000 (3M), tinha intensidade de 470mW/cm2 e comprimento de onda entre 400 e 510nm; o LED Smart Lite PS (Dentsply) tinha intensidade de 950mW/cm2 e comprimento de onda entre 450 e 490nm. O tempo de fotopolimerização para cada incremento com 2mm de espessura foi de 40 s. para a lâmpada halógena convencional e 10 s. para o LED. Para os testes de microdureza Knoop foram confeccionadas 20 amostras numa matriz cilíndrica com 8,0mm de diâmetro e 2,0mm de altura. As leituras da microdureza foram realizadas nas superfícies superiores e inferiores das amostras utilizando um microdurômetro Micromet 2003, com uma carga de 50 gf por 15 s. Para o teste de resistência à compressão foram confeccionadas 40 amostras numa matriz cilíndrica com 4,0mm de diâmetro e 8,0mm de altura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 500Kgf e velocidade de carregamento de 0,5 mm/min. Para o teste de resistência flexural foram construídas 40 amostras numa matriz em forma de caixa com 25,0mm de comprimento, 2,0mm de altura e 2,0mm de largura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 50Kgf e velocidade de carregamento de 0,5 mm/min. Cada material foi caracterizado pela termogravimetria, espectrometria no infravermelho, espectrometria de ressonância magnética nuclear, teor de cinzas, fluorescência de raios-X e microscopia eletrônica de varredura. Os resultados foram tratados por ANOVA e teste de SNK (p<0,05). Os resultados de microdureza Knoop, resistência à compressão e resistência flexural providos pela luz halógena foram melhores que os dos LED. A resina composta apresentou melhor performance que o compômero em todos os testes. / The goal of this work was to evaluate the effects of the blue light emitting diodes (LEDs) Smart Lite PS (Dentsply) and the conventional halogen lamp Curing Light XL 3000 (3M) on the polymerization effectiveness of the Dyract Ap compomer (Dentsply) and the TPH Spectrum composite resin (Dentsply) by the Knoop microhardness, compressive strength, flexural strength and material characterization tests. A hundred samples were prepared and divided into 12 groups according to the test applied, the polymerization light and the material. The conventional halogen lamp light had power of 470mW/cm and wavelength between 400 and 510nm; the LED light had power of 950mW/cm and wavelength between 450 and 490nm. The polymerization time for each material 2mm buildup was 40 seconds for the conventional halogen lamp and 10 seconds for LED. For the Knoop microhardness tests the 20 samples were cylinder shaped, 8mm diameter and 2mm height. The hardness was read in the upper and lower side of the samples by a micrometer (Micromet 2003), with 50 gf for 15 seconds. For the compressive strength test the 40 samples were cylinder shaped, 4mm diameter and 8mm height. The strength was measured in an universal testing machine Emic DL 10.000 with 500Kgf and cross-head speed of 0,5 mm/min. For the flexural strength test the 40 samples were box shaped, 25mm length, 2mm width and 2mm height. The strength was measured in an universal testing machine Emic DL 10.000 machine with 50Kgf and cross-head speed of 0,5 mm/min. Each material was characterized by Thermogravimetry, FT-IR analysis, Nuclear Magnetic Resonance, Ash Content Test, X-Ray Fluorescence and Scanning Electron Microscopy. The results were treated by ANOVA and SNK tests (p<0,05). The Knoop microhardness, compressive strength and flexural strength results provided by the halogen light lamp were better than the LED ones. The composite resin performed better than the compomer in all mechanical tests.
4

Avaliação da efetividade da fotoativação de dois materiais resinosos com diferentes fontes de luz, por meio da microdureza Knoop, resistência à compressão, resistência flexural e caracterização dos materiais / Evaluation of the effect of the light source on the photo polymerization of two resin material by the Knoop microhardness, compressive strength, flexural strength and material characterization

Cecy Martins Silva 15 September 2006 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / O objetivo deste trabalho foi avaliar o efeito de um diodo emissor de luz (LED) Smart Lite PS (Dentsply) e da lâmpada halógena convencional Curing Light XL 3000 (3M) na efetividade de polimerização do compômero Dyract Ap (Dentsply) e da resina composta TPH Spectrum (Dentsply) por meio de testes de microdureza Knoop, resistência à compressão e resistência flexural e caracterização dos materiais. Foram confeccionadas 100 amostras e divididas em 12 grupos de acordo com o teste aplicado, a luz de polimerização e o material utilizado. A lâmpada halógena convencional selecionada, Curing Light XL 3000 (3M), tinha intensidade de 470mW/cm2 e comprimento de onda entre 400 e 510nm; o LED Smart Lite PS (Dentsply) tinha intensidade de 950mW/cm2 e comprimento de onda entre 450 e 490nm. O tempo de fotopolimerização para cada incremento com 2mm de espessura foi de 40 s. para a lâmpada halógena convencional e 10 s. para o LED. Para os testes de microdureza Knoop foram confeccionadas 20 amostras numa matriz cilíndrica com 8,0mm de diâmetro e 2,0mm de altura. As leituras da microdureza foram realizadas nas superfícies superiores e inferiores das amostras utilizando um microdurômetro Micromet 2003, com uma carga de 50 gf por 15 s. Para o teste de resistência à compressão foram confeccionadas 40 amostras numa matriz cilíndrica com 4,0mm de diâmetro e 8,0mm de altura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 500Kgf e velocidade de carregamento de 0,5 mm/min. Para o teste de resistência flexural foram construídas 40 amostras numa matriz em forma de caixa com 25,0mm de comprimento, 2,0mm de altura e 2,0mm de largura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 50Kgf e velocidade de carregamento de 0,5 mm/min. Cada material foi caracterizado pela termogravimetria, espectrometria no infravermelho, espectrometria de ressonância magnética nuclear, teor de cinzas, fluorescência de raios-X e microscopia eletrônica de varredura. Os resultados foram tratados por ANOVA e teste de SNK (p<0,05). Os resultados de microdureza Knoop, resistência à compressão e resistência flexural providos pela luz halógena foram melhores que os dos LED. A resina composta apresentou melhor performance que o compômero em todos os testes. / The goal of this work was to evaluate the effects of the blue light emitting diodes (LEDs) Smart Lite PS (Dentsply) and the conventional halogen lamp Curing Light XL 3000 (3M) on the polymerization effectiveness of the Dyract Ap compomer (Dentsply) and the TPH Spectrum composite resin (Dentsply) by the Knoop microhardness, compressive strength, flexural strength and material characterization tests. A hundred samples were prepared and divided into 12 groups according to the test applied, the polymerization light and the material. The conventional halogen lamp light had power of 470mW/cm and wavelength between 400 and 510nm; the LED light had power of 950mW/cm and wavelength between 450 and 490nm. The polymerization time for each material 2mm buildup was 40 seconds for the conventional halogen lamp and 10 seconds for LED. For the Knoop microhardness tests the 20 samples were cylinder shaped, 8mm diameter and 2mm height. The hardness was read in the upper and lower side of the samples by a micrometer (Micromet 2003), with 50 gf for 15 seconds. For the compressive strength test the 40 samples were cylinder shaped, 4mm diameter and 8mm height. The strength was measured in an universal testing machine Emic DL 10.000 with 500Kgf and cross-head speed of 0,5 mm/min. For the flexural strength test the 40 samples were box shaped, 25mm length, 2mm width and 2mm height. The strength was measured in an universal testing machine Emic DL 10.000 machine with 50Kgf and cross-head speed of 0,5 mm/min. Each material was characterized by Thermogravimetry, FT-IR analysis, Nuclear Magnetic Resonance, Ash Content Test, X-Ray Fluorescence and Scanning Electron Microscopy. The results were treated by ANOVA and SNK tests (p<0,05). The Knoop microhardness, compressive strength and flexural strength results provided by the halogen light lamp were better than the LED ones. The composite resin performed better than the compomer in all mechanical tests.
5

Desenvolvimento de uma fonte luminosa baseada em lâmpadas halógenas para aplicações na fotobiologia e fotomedicina / Development of a light source based in halogen lamps for applications in the photobiology and photomedicine.

Wagner Fonzi 15 August 2008 (has links)
Este projeto teve como finalidade construir uma fonte de luz baseada em lâmpadas halógenas que apresentasse características técnicas adequadas para aplicações em fotobiologia e fotomedicina, versátil e comercialmente viável. Foram analisadas as características de diferentes lâmpadas halógenas e realizados os experimentos com duas lâmpadas escolhidas, das quais utilizamos a lâmpada de menor divergência luminosa. Foi analisado também o material do corpo da fonte, com relação a características de aquecimento e peso, sendo escolhido um corpo de alumínio produzido industrialmente. Foram avaliadas as características ópticas das lentes, sendo escolhidas as lentes de vidro utilizadas em retroprojetores. Foram analisados os materiais e a construção de filtros térmicos para diminuir o aquecimento do objeto sob irradiação, sendo que escolhemos construir um filtro térmico próprio, que utiliza a água como absorvedor de calor. Medimos e avaliamos as características: espectrais, térmicas, a potência radiante (irradiância) e sua distribuição espacial de três protótipos, onde cada um recebeu modificações de modo a torná-los mais adequados para aplicações na fotoquimeoterapia. Foram também realizados testes preliminares de fotocitotoxicidade do protótipo final com o composto fotossensibilizador de nome comercial Photogem® aplicado em células tumorais de adenocarcinoma de colo retal humano (HT29), cujo resultado foi a ativação do composto fotossensibilizador e indução da morte celular. / The aim of this work was to produce a light source based in halogen lamps. This source should have appropriated technical characteristic for application in photobiology and photomedicine, it has easy operation and be commercially viable. The characteristics of different halogen lamps were evaluated and the lamp of smaller luminous divergence was chosen. We also have evaluated the material of the source holder, especially heating characteristics and weight; finally we chose an aluminum holder. Then, the lenses optical characteristics were studied, and we decided that the glass lenses used in projectors were the best. The materials and the construction of thermal filters were evaluated in order to reduce the heating of the object under irradiation, and we preferred to construct a thermal filter, that uses water as an heat absorber. The spectral and thermal characteristics, the radiant power (irradiance) and its space distribution of three prototypes were measured and evaluated, each one received modifications to become more appropriated to applications in photochemotherapy. We also made preliminaries tests of photocytotoxicity and the final prototype was used with the photosensitizer (Photogem®) in human colon carcinoma cell lines HT-29, resulting in the photosensitizer activation, that induced cellular death.
6

Efeito da fonte de luz e enxaguatórios bucais na microdureza longitudinal de resinas compostas diretas. Análise complementar por espectroscopia Raman / Effect of the light curing units and mouthrise in the longitudinal microhardness of direct composite resins. Backing analysis for Ramam spectroscopy

Silva, Flaviane Renó Gonzaga 26 June 2009 (has links)
Neste estudo foi realizada avaliação longitudinal da microdureza Vickers e análise complementar do grau de conversão, de resinas compostas diretas, pelo método de espectroscopia Raman. As resinas compostas estudadas (M1: Charisma, M2: Z100 e M3: Filtek Supreme) foram fotopolimerizadas por diferentes fontes de luz (F1: Diodo emissor de F2: Luz e Halógena) e submetidos à ação de diferentes enxaguatórios bucais (S1: Saliva artificial, S2: Listerine e S3: Cepacol) e analisadas nas diferentes profundidades (P1 = 2mm, P2 = 4mm e P3 = 6mm). Para análise de microdureza Vickers - VHN (kg/cm3) foram confeccionados 07 corpos-de-prova (cp) para cada condição experimental (total = 180) por meio de matrizes em teflon, constituídas de dois dispositivos, o primeiro contendo uma cavidade de 02X04X06mm de base arredondada e um segundo dispositivo de superfície lisa que foi contraposto ao primeiro, as leituras foram realizadas 24 horas após a confecção dos cp por meio do microdurômetro Shimadzu HMV-200. A análise espectroscópica foi realizada por espectroscopia Raman (espalhamento Raman) (GC), para tal foram selecionadas aleatoriamente 06 amostras de cada resina estudada, das condições experimentais propostas (dentre as utilizadas para o teste de microdureza) e obtidos 06 cp para cada profundidade (total = 18 para cada resina), conforme metodologia preconizada pelo Laboratório do Departamento de Química da FFCLRP-USP. Os valores obtidos foram submetidos à análise de variância (ANOVA) e, para as comparações individuais, foi realizado o teste de Tukey (p<0,05). Os resultados permitiram observar que para o fator Profundidade os valores de VHN e GC foram maiores para P1 e menores para P3 nas resinas R1 e R3; para o fator Fonte F2 determinou maiores valores de VHN para R1 e R2 e maiores valores de GC para todas as resinas analisadas; para o fator Solução S3 determinou maiores valores de VHN para todas as resinas, no entanto, não houve diferença no GC entre as Soluções; entre as resinas R2>R3>R1 para VHN e para DC R3>R1>R2. Logo, todos os fatores analisados influenciaram a microdureza e o grau de conversão das resinas. / In this study was made longitudinal evaluation of the microhardness Vickers and backing analysis of the conversion degree was accomplished, of direct composite resins, by the method of Raman spectroscopy. The composite resins studied (M1: Charisma, M2: Z100 and M3: Filtek Supreme) was photopolymerized by different sources of light (F1: light emitting diode and F2:quartz-tungsten-halogenous) and submitted to the action of different mouthrise (S1: Artificial saliva, S2: Listerine and S3: Cepacol) and analysed in the different depths (P1= 2mm, P2= 4mm e P3= 6mm). For analysis of microhardness Vickers - VHN (kg/cm3) were confectioned 07 samples for each experimental condition (total = 180) by means of matrix in teflon, constituted of two devices, first containing a socket of 02X04X06mm of rounded base and a second dispositive of smooth surface that was opposed to first, the readings were accomplished 24 hours after the confection of sample by means of the equipmente Shimadzu HMV-200. The spectroscopic analysis was accomplished by Raman spectroscopy (Raman scattering) (DC), for such 06 samples of each studied resin were selected randomly, of the experimental conditions proposals (amongst the used ones for the microhardness test) e obtained 06 samples for each depth (total=18 for each resin), as methodology praised for the Laboratory of the Department of Chemistry of the FFCLRP-USP. The obtained values were submitted to the analysis of variance (ANOVA) and, for the individual matchings, were accomplished the test of Tukey (p<0,05). The results had allowed to observe that for the factor Depth the values of VHN and DC were bigger for P1 and lesser for P3 in the resins R1 and R3; for the factor F2 Source it determined greaters values of VHN for R1 and R2 and greaters values of DC for all the analysed resins; for the factor S3 Solution it determined greaters values of VHN for all the resins, however, it did not have difference in the DC between the Solutions; between resins R2>R3>R1 for VHN and for DC R3>R1>R2. Soon, all the analysed factors had influenced the microhardness and the degree of conversion of resins.
7

Efeito da fonte de luz e enxaguatórios bucais na microdureza longitudinal de resinas compostas diretas. Análise complementar por espectroscopia Raman / Effect of the light curing units and mouthrise in the longitudinal microhardness of direct composite resins. Backing analysis for Ramam spectroscopy

Flaviane Renó Gonzaga Silva 26 June 2009 (has links)
Neste estudo foi realizada avaliação longitudinal da microdureza Vickers e análise complementar do grau de conversão, de resinas compostas diretas, pelo método de espectroscopia Raman. As resinas compostas estudadas (M1: Charisma, M2: Z100 e M3: Filtek Supreme) foram fotopolimerizadas por diferentes fontes de luz (F1: Diodo emissor de F2: Luz e Halógena) e submetidos à ação de diferentes enxaguatórios bucais (S1: Saliva artificial, S2: Listerine e S3: Cepacol) e analisadas nas diferentes profundidades (P1 = 2mm, P2 = 4mm e P3 = 6mm). Para análise de microdureza Vickers - VHN (kg/cm3) foram confeccionados 07 corpos-de-prova (cp) para cada condição experimental (total = 180) por meio de matrizes em teflon, constituídas de dois dispositivos, o primeiro contendo uma cavidade de 02X04X06mm de base arredondada e um segundo dispositivo de superfície lisa que foi contraposto ao primeiro, as leituras foram realizadas 24 horas após a confecção dos cp por meio do microdurômetro Shimadzu HMV-200. A análise espectroscópica foi realizada por espectroscopia Raman (espalhamento Raman) (GC), para tal foram selecionadas aleatoriamente 06 amostras de cada resina estudada, das condições experimentais propostas (dentre as utilizadas para o teste de microdureza) e obtidos 06 cp para cada profundidade (total = 18 para cada resina), conforme metodologia preconizada pelo Laboratório do Departamento de Química da FFCLRP-USP. Os valores obtidos foram submetidos à análise de variância (ANOVA) e, para as comparações individuais, foi realizado o teste de Tukey (p<0,05). Os resultados permitiram observar que para o fator Profundidade os valores de VHN e GC foram maiores para P1 e menores para P3 nas resinas R1 e R3; para o fator Fonte F2 determinou maiores valores de VHN para R1 e R2 e maiores valores de GC para todas as resinas analisadas; para o fator Solução S3 determinou maiores valores de VHN para todas as resinas, no entanto, não houve diferença no GC entre as Soluções; entre as resinas R2>R3>R1 para VHN e para DC R3>R1>R2. Logo, todos os fatores analisados influenciaram a microdureza e o grau de conversão das resinas. / In this study was made longitudinal evaluation of the microhardness Vickers and backing analysis of the conversion degree was accomplished, of direct composite resins, by the method of Raman spectroscopy. The composite resins studied (M1: Charisma, M2: Z100 and M3: Filtek Supreme) was photopolymerized by different sources of light (F1: light emitting diode and F2:quartz-tungsten-halogenous) and submitted to the action of different mouthrise (S1: Artificial saliva, S2: Listerine and S3: Cepacol) and analysed in the different depths (P1= 2mm, P2= 4mm e P3= 6mm). For analysis of microhardness Vickers - VHN (kg/cm3) were confectioned 07 samples for each experimental condition (total = 180) by means of matrix in teflon, constituted of two devices, first containing a socket of 02X04X06mm of rounded base and a second dispositive of smooth surface that was opposed to first, the readings were accomplished 24 hours after the confection of sample by means of the equipmente Shimadzu HMV-200. The spectroscopic analysis was accomplished by Raman spectroscopy (Raman scattering) (DC), for such 06 samples of each studied resin were selected randomly, of the experimental conditions proposals (amongst the used ones for the microhardness test) e obtained 06 samples for each depth (total=18 for each resin), as methodology praised for the Laboratory of the Department of Chemistry of the FFCLRP-USP. The obtained values were submitted to the analysis of variance (ANOVA) and, for the individual matchings, were accomplished the test of Tukey (p<0,05). The results had allowed to observe that for the factor Depth the values of VHN and DC were bigger for P1 and lesser for P3 in the resins R1 and R3; for the factor F2 Source it determined greaters values of VHN for R1 and R2 and greaters values of DC for all the analysed resins; for the factor S3 Solution it determined greaters values of VHN for all the resins, however, it did not have difference in the DC between the Solutions; between resins R2>R3>R1 for VHN and for DC R3>R1>R2. Soon, all the analysed factors had influenced the microhardness and the degree of conversion of resins.
8

Efeito do tipo de fonte de luz sobre propriedades físicas de cimentos resinosos experimentais contendo diferentes sistemas fotoiniciadores / Effect of light curing units on the physical properties of experimental resin cements containing different photoinitiators systems

Leonardo Freitas da Silveira 25 March 2013 (has links)
Cimentos resinosos experimentais contendo diferentes sistemas fotoiniciadores apresentaram propriedades físicas semelhantes ou superiores a cimentos resinosos convencionais sob efeito de diferentes tipos de fonte de luz. Objetivo: Analisar o espectro de diferentes fontes de luz e sistemas fotoiniciadores e sua influência nas propriedades físicas de cimentos resinosos quando ativados, através de um anteparo cerâmico, por fontes de luz halógena e LED. Metodologia: Cimentos resinosos experimentais contendo uma mistura de BisGMA, TEGDMA (50wt%) e partículas de carga silanizadas (65wt%), foram preparados com o uso dos fotoiniciadores Canforoquinona (CQ), Fenil Propanodiona (PPD) e Óxido bis-alquil fosfínico (BAPO) de forma isolada e combinados. Os co-iniciadores utilizados foram Difenil Iodônio (DFIHFP) e a amina terciária DMAEMA. As fontes de luz utilizadas foram: lâmpada halógena (XL 2500) e duas fontes de diodo emissor de luz - LED (FreeLigth 2 e Bluephase). Um anteparo cerâmico (IPS e.max Press) apresentando 13,0mm x 1,0mm de espessura foi utilizado durante os testes. Amostras com 7,0mm x 2,0mm x 1,0mm foram confeccionadas (n=360). A avaliação do Grau de Conversão (GC) dos cimentos experimentais foi realizada por Espectroscopia de Infravermelho Transformada de Fourier (FTIR), sendo em seguida submetidas ao teste de resistência à mini-flexão, módulo flexural e microdureza Knoop. Os resultados obtidos em todos os testes foram submetidos à análise de variância dois fatores - ANOVA e teste de Tukey (5%). Resultados: A associação do DFIHFP aos fotoiniciadores aumentou as propriedades avaliadas de todos os cimentos experimentais independente da fonte de luz (FL) utilizada. O fotoiniciador BAPO apresentou resultados superiores ou iguais estatisticamente em comparação ao grupo controle (CQ/amina), independente da FL utilizada. Conclusão: A utilização de sistemas iniciadores e co-iniciadores alternativos possibilita a obtenção de propriedades superiores ou iguais ao sistema convencional, tornando-se um sistema promissor para atuar de forma isolada ou associada. / Resin cements containing different experimental photoinitiators systems present physical properties similar to or better than conventional resin cements under the effect of different types of light source. Objective: To analyze the spectrum of different light sources and systems photoinitiators and their influence on physical properties of resin cements when activated through a bulkhead ceramic, halogen light sources and LED. Methodology: experimental resin cements containing a mixture of BisGMA, TEGDMA (50wt%) and silanized filler particles (65wt%) were prepared with the use of photoinitiators camphorquinone (CQ), phenyl oxide bis-propanedione (PPD) and alkyl phosphinic (BAPO) separately and combined. The primers used were co-diphenyl iodonium (DFIHFP) tertiary amine and DMAEMA. The light sources used were: halogen lamp (XL 2500) and two sources of light emitting diode - LED (FreeLigth bluephase and 2). A ceramic shield (IPS e.max Press) having 13.0mm x 1.0mm thick was used for testing. Samples with 7.0mm x 2.0mm x 1.0mm were fabricated (n=360). The evaluation of the degree of conversion (GC) of experimental cements was performed by Infrared Spectroscopy Fourier Transform, and then to test for resistance to mini-bending, flexural modulus and microhardness. The results in all tests were subjected to two-factor analysis of variance - ANOVA and Tukey test (5%). Results: The combination of photoinitiators DFIHFP to improve board properties of all the experimental cements independent light source (LCU) used. The photoinitiator BAPO showed statistically equal or better results compared to the control group (CQ / amine), regardless of LCU used. Conclusion: The use of systems co-initiators and initiators to obtain alternative provides equal or better properties to the conventional system, making it a promising system to act in isolation or in combination.
9

Projeto e implementação de lâmpadas para iluminação de interiores empregando diodos emissores de luz(LEDS) / Design and implementation of interior lighting systems using light emitting diodes(LEDS)

Pinto, Rafael Adaime 31 October 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work presents an efficient lighting system using high intensity light emitting diodes (LEDs). The goal is to develop a compact and low cost electronic circuit to drive and control the current of LEDs disposed in a single enclosure. The proposal aims energy saving, high luminous efficacy and high useful life when replacing traditional lighting systems, as dichroic, incandescent or compact fluorescent lamps by LEDs without any change in electrical system installation. Furthermore, an emergency lighting system integrated into the lamp is proposed, allowing the use of the same equipment in the daily activities, supplied by mains, and under a possible break in the electrical network. To supply the LEDs through the mains with universal input voltage and charge the battery, a Buck converter was employed. To supply the LEDs with a continuous current through the battery, a Boost converter was used. The converters operate at high frequency and control the current through the LEDs independently. The battery can be composed of three rechargeable Ni-MH batteries (1,2 V) or a Li-ion battery (3,6 V). The design attends the Brazilian standard and international standard for emergency lighting systems. To validate the proposed idea, the circuits were designed and implemented. The experimental results are shown with the intention to prove the satisfactory behavior of the lamps. / Este trabalho apresenta um sistema de iluminação eficiente empregando diodos emissores de luz (LEDs) de alta intensidade. O objetivo é desenvolver um circuito eletrônico, compacto e de baixo custo, para acionamento e controle da corrente dos LEDs contidos em um único invólucro. A proposta visa a racionalização no uso da energia elétrica através de uma elevada eficácia luminosa e longa vida útil na substituição dos sistemas de iluminação tradicionais, como lâmpadas dicróicas, incandescentes ou fluorescentes compactas, por LEDs sem qualquer alteração na instalação elétrica. Além disso, é proposto um sistema de iluminação de emergência integrado a esta lâmpada, permitindo a utilização de um único equipamento para iluminação convencional, alimentada pela rede elétrica, e sob uma possível falha no fornecimento de energia. Para alimentar os LEDs, através da rede elétrica, com tensão de entrada universal e ainda carregar a bateria, um conversor Buck é empregado. Para alimentar os LEDs em corrente contínua através da bateria, um conversor Boost é utilizado. Os conversores operam em alta freqüência e controlam a corrente nos LEDs de forma independente. A bateria pode ser composta por três pilhas recarregáveis de Ni-MH (1,2 V) ou por uma bateria de Li-Ion (3,6 V). O projeto atende às exigências da norma brasileira (NBR 10898) e da norma internacional (IEEE Std 446-1995) para sistemas de iluminação de emergência. Para analisar a idéia proposta, os circuitos são projetados e implementados. Os resultados experimentais são apresentados de forma a comprovar o comportamento satisfatório das lâmpadas.

Page generated in 0.0779 seconds