• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 23
  • 10
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 84
  • 84
  • 33
  • 29
  • 24
  • 22
  • 16
  • 15
  • 14
  • 12
  • 11
  • 11
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

[en] FORCED CONVECTION OF A CHANNEL PARTIALLY BLOCKED BY A HEAT DISSIPATING ELEMENT / [pt] CONVECÇÃO FORCADA EM UM CANAL PARCIALMENTE OBSTRUÍDO POR UM ELEMENTO GERADOR DE CALOR: UMA INVESTIGAÇÃO NUMÉRICA

SERGIO LUIZ FREY 15 March 2018 (has links)
[pt] No presente trabalho foi realizada uma investigação numérica de um escoamento forçado em um canal plano parcialmente construído por um elemento retangular aquecido com temperatura da parede constante. O elemento tem dimensões fixas e foi estudado em diferentes posições do canal, ao passo que este tem comprimento fixo e largura variável, de modo a obter-se uma razão de aspecto entre 21,8 e 4,0. A faixa investigada do número de Reynolds foi de 100 a 1500, e o número de Prandtl foi fixado em 0,7, a fim de simular escoamento de ar com propriedades constantes. O método numérico utilizado na resolução das equações de conservação que regem o escoamento foi o método dos volumes de controle desenvolvido por Suhas V. Patankar. A partir dos perfis de velocidade, pressão e temperatura foram calculados a perda de carga ao longo do canal e o número de Nusselt médio em torno do elemento. Foram também realizadas comparações com outros trabalhos; tanto dos resultados hidrodinâmicos como dos térmicos, e boas concordâncias foram obtidas. / [en] A numerical investigation of a forced flow in a partially obstructed plate channel was performed in the present work. The obstruction was an isothermal rectangular element. The effect of the element, which had fixed dimensions, was studied for different channel positions. The channel had a fixed length but its width was variable, making it possible to obtain an aspect ratio between 21,8 and 4.0. The investigation was made for Reynolds number from 100 to 1500 and the Prandtl number was fixed at 0.7, to simulate a constant property air flow. The numerical method used in the solution of the conservation law equations which govern the flow was the control volume numerical method, developed by Suhas V. Patankar. From the velocity, pressure and temperature profiles, the head loss along the channel and the average Nusselt number around the element surface. The hydrodynamical and thermal results were compared, when possible, with previous papers, and a good agreement was obtained.
32

[en] INTERNAL AIRFLOW OVER A MATRIX OF RECTANGULAR BLOCKS: EFFECT OF NONUNIFORMITIES IN HEAT TRANSFER AND PRESSURE DROP / [pt] ESCOAMENTO INTERNO DE AR SOBRE UMA MATRIZ DE MÓDULOS RETANGULARES: EFEITOS DE NÃO-UNIFORMIDADES NA TRANSFERÊNCIA DE CALOR E PERDA DE CARGA

WILSON FERNANDO NOGUEIRA DOS SANTOS 03 April 2018 (has links)
[pt] Efeitos na transferência de calor e perda de carga de uma matriz de módulos retangulares, localizada no interior de um duto retangular plano, foram analisados experimentalmente tendo-as ar como fluido de trabalho. A pesquisa foi desenvolvida objetivando simular a refrigeração de componentes eletrônicos por convecção forçada. Aplicando-se a técnica de sublimação de naftaleno determinaram-se os coeficientes de transferência de massa (calor) para três situações investigadas durante o curso da experiência. São elas: (a) para a matriz base formada apenas por módulos regulares, (b) para um módulo alto inserido em todas as posições na linha de centro na matriz, (c) para os módulos vizinhos ao módulo alto na matriz. A partir dos resultados obtidos, determinaram-se correlações para o Número de Sherwood em função do Número de Reynolds compreendido na faixa de 2000 a 7000. O Número de Sherwood do môdulo alto, mostrou-se substancialmente maior comparado com o módulo regular da mesma posição. Esse acréscimo foi da ordem de 90 por cento a 95 por cento na região completamente desenvolvida, para baixo Número de Reynolds. Verificou-se que a presença do módulo alto causou um significativo aumento no coeficiente de transferência de calor nos modulos vizinhos, atingindo em alguns casos, aumento de 50 por cento. O módulo posicionado ao lado do módulo alto acusou o maior acréscimo de transferência de calor. Medidas de pressão na matriz sem e com módulo alto foram realizadas. Com a introdução do módulo alto, um acréscimo na perda de carga for verificado, sendo que, para o menor Número de Reynolds, este incremento corresponde a perda de carga equivalente a aproximadamente seis fileiras de módulos regulares. / [en] Heat transfer and pressure drop characteristics an array of rectangular modules inside a rectangular duct were experimentally studied using air as the working fluid. The research was conducted with the aim of simulating the cooling of eletronic components by forced convection. Mass ( Heat ) transfer coefficients were determined via naphthalene sublimation technique for three different situations, namely (a) for modules in the basic array, composed of regular modules only, (b) for a tall module positioned at all positions in the array center longitudinal row, and (c) for the modules in the neighborhood of the tall module. With basis on the results obtained, relations for the Sherwood (Nusselt) Number were obtained as a function of the Reynolds Number, which varied from 2000 to 7000. The Sherwood Number for the tall module was found to be higher than the one for the regular module at the same position. This increase was of the order of 90-95 percent, in the fully developed region and for low Reynolds Number. It was found that the presence tall module caused of the significant enhancements on the heat (mass) transfer coefficient of the neighboring modules, reaching in same cases 50 percent increases. The regular modules situated by the sides of the tall module underwent the highest enhancements on heat transfer. Pressure Measurements on the array with and without the tnll module where performed. In the presence of the tall module, an additional pressure loss was observed, being equivalent to the loss associated with approximately six transversal rows of regular modules, for the lower Reynolds Number.
33

Resfriamento conjugado de aquecedores protuberantes em um duto retangular / Conjugate cooling of protruding heaters in a rectangular duct

Loiola, Bruna Rafaella, 1987- 12 May 2013 (has links)
Orientador: Carlos Alberto Carrasco Altemani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-24T09:07:23Z (GMT). No. of bitstreams: 1 Loiola_BrunaRafaella_M.pdf: 2801156 bytes, checksum: 0bbef2296c5a3a938f63b6246554ab2d (MD5) Previous issue date: 2013 / Resumo: A transferência de calor conjugada por convecção forçada-condução de dois aquecedores protuberantes montados na parede inferior (substrato) de um duto retangular foi investigada através de medidas experimentais em laboratório. Potência elétrica era dissipada em resistências embutidas nos aquecedores feitos de alumínio, que eram resfriados em regime permanente por um escoamento forçado de ar no duto. Cada aquecedor transferia calor por convecção diretamente das suas superfícies em contato com o escoamento e por condução para a placa do substrato através da interface comum. Esta condução de calor espalhava na placa do substrato e era transferida por convecção da placa para o escoamento de ar no duto. O resfriamento conjugado dos aquecedores na placa de substrato foi descrito por uma matriz de coeficientes conjugados obtidos por meio de testes experimentais realizados com um aquecedor ativo por vez, em uma faixa do número de Reynolds do escoamento entre 1600 e 6400. Foram utilizadas duas montagens experimentais praticamente idênticas, uma com a placa do substrato de acrílico e a outra, de alumínio. O número de Nusselt adiabático, que é um descritor invariante do processo convectivo de troca de calor, também foi avaliado nos testes com o substrato de acrílico. Os coeficientes conjugados obtidos nestes testes foram então utilizados para prever as temperaturas dos aquecedores em testes adicionais com os dois simultaneamente ativos, sob condições variadas de escoamento e aquecimento. A concordância dessas temperaturas indicou que esses coeficientes são descritores invariantes do resfriamento conjugado dos aquecedores discretos no duto. Simulações numéricas do escoamento e da transferência de calor no duto considerado foram efetuadas com o pacote computacional PHOENICS em um domínio tridimensional semelhante ao duto experimental. Os resultados numéricos obtidos foram comparados com as medidas experimentais / Abstract: Conjugate heat transfer by forced convection-conduction of two protruding heaters mounted on the lower wall (substrate) of a rectangular duct was investigated through experiments in laboratory. Electric power dissipation in the Aluminum heaters¿ embedded resistances was transferred under steady state conditions to forced airflow in the duct. Heat losses from each heater included direct convection from its surfaces in contact with the airflow and conduction to the substrate plate through their common interface. This heat conduction was spread in the substrate plate and eventually transferred by convection from the plate to the airflow in the duct. The heaters¿ conjugate cooling was described by a conjugate matrix with coefficients obtained from experimental tests with a single active heater at a time, in the range of the airflow Reynolds number from 1,600 to 6,400. Two almost identical assemblies were used, one with a Plexiglas plate and the other with Aluminum. The adiabatic Nusselt number, an invariant descriptor of the convective heat transfer, was also evaluated in the tests with the Plexiglas plate. The conjugate coefficients were used to predict the heaters¿ temperatures from additional tests with both active heaters, for arbitrary airflow rates and heaters¿ power dissipation. An agreement of these temperatures indicated that the conjugate coefficients are invariant descriptors of their conjugate cooling. Numerical CFD simulations were performed using the PHOENICS software in a three dimensional domain similar to the experimental assembly. The numerical results were compared to those of the experiments / Mestrado / Termica e Fluidos / Mestra em Engenharia Mecânica
34

Numerical Simulation of Magnetohydrodynamic (MHD) Effect on Forced, Natural and Mixed Convection Flows

Kalapurakal, Dipin 13 August 2012 (has links)
No description available.
35

Corrosion Studies of Molten Chloride Salt: Electrochemical Measurements and Forced Flow Loop Tests

Zhang, Mingyang 23 August 2023 (has links)
This study encompasses various aspects of corrosion in chloride molten salt environments, employing electrochemical techniques and a forced convection loop. It explores corrosion thermodynamic properties, electrochemical corrosion kinetics, and flow-induced dynamic corrosion. The study developed a novel electrochemical method for measuring thermodynamic properties of corrosion products and develops a new analysis theory for potentiodynamic polarization data obtained from cathodic diffusion-controlled reactions. Additionally, the design and operation experience of a forced convection chloride molten salt loop is shared. Particularly, the study presents novel findings on the turbulent flow-induced corrosion phenomenon and mechanism of Fe-based alloys in Mg-based chloride molten salt. These outcomes provide valuable insights into the corrosion mechanisms and flow-induced corrosion of Fe-based alloys in chloride molten salt. The results and experiences shared in this paper have implications for the successful implementation of molten salt as an advanced heat transfer fluid and thermal energy storage material in high-temperature applications, benefiting the nuclear and concentrating solar communities. / Doctor of Philosophy / This study explores the corrosion behavior of materials chloride molten salt, which is used in advanced energy systems. By using advanced techniques, the researchers investigated how these materials react and corrode in different conditions. They developed new methods to measure the properties of the corrosion products and analyzed how different factors affect the corrosion process. Additionally, they shared their experiences in building and operating a flow loop to simulate these conditions. The study discovered interesting phenomena, such as how the flow of molten salt can cause corrosion in certain types of metals. These findings provide important insights for improving the use of molten salt as a heat transfer fluid and energy storage material in advanced energy technologies.
36

A Numerical Study of Transport Phenomena in Porous Media

Liou, May-Fun 09 June 2005 (has links)
No description available.
37

NUMERICAL, EXPERIMENTAL AND ANALYTICAL STUDY OF THERMAL HEATING OF SPHERE AND DISK SHAPED BIOCRYSTALS EXPOSED TO 3 <sup>RD</sup>GENERATION SYNCHROTON SOURCES

SAMPATH KUMAR, RAGHAV 02 October 2006 (has links)
No description available.
38

Experimental and theoretical analysis of single-phase convective heat transfer in channel with resistive heater and thermoelectric modules for hydronic cooling and heating device

Gupta, Abhishek 17 April 2009 (has links)
No description available.
39

Experimental Study - High Altitude Forced Convective Cooling of Electromechanical Actuation Systems

Racine, Evan Michael January 2015 (has links)
No description available.
40

Solução numérica de escoamentos termofluidodinâmicos bidimensionais laminares pelo método de Lattice-Boltzmann / Numerical solution of two-dimensional laminar thermofluidynamic flows using Lattice-Boltzmann Method

Mapelli, Vinícius Pessôa 22 February 2019 (has links)
O método de Lattice-Boltzmann (MLB) vem ganhando destaque nas últimas décadas pela sua capacidade de solução de escoamentos complexos como escoamentos multifásicos e multicomponentes, meios porosos e magnetohidrodinâmicos. Também existem extensões do método para a solução de problemas de advecção-difusão, que permitem acoplamento dessa metodologia para a solução numérica do conjunto de equação Navier-Stokes-Fourier. No trabalho presente, os objetivos iniciais podem ser resumidos no estudo dos conceitos básicos necessários para entender a derivação do método a partir da teoria cinética e estudo do método de Lattice Boltzmann, com operador de colisão mais simples conhecido como operador BGK, para problemas bidimensionais térmicos e fluidodinâmicos. A implementação numérica do método foi realizada em linguagem C, Matlab e CUDA C, com foco na solução de cinco problemas incompressíveis e laminares em regime permanente, conhecidos na literatura: equação viscosa de Burgers, escoamento de Poiseuille com transferência de calor, convecção natural em uma cavidade quadrada, regimes de convecção natural, forçada e mista em uma cavidade com uma das fronteiras móvel, e por fim, convecção forçada em uma cavidade ventilada, com uma entrada e uma saída. Além disso, um pequeno estudo no tempo computacional utilizando três implementações distintas foram testadas: implementação em série, uso de interpolações entre malhas grosseiras como condição inicial para malhas mais refinadas, e por fim, a adição da implementação do código em paralelo. Os ganhos de tempo entre a primeira e segunda estratégia ficaram entre 1.5 e 6, ao passo que o código paralelizado mostrou-se entre 20 e 25 vezes mais rápido que a segunda estratégia testada, comprovando o benefício de utilizar o processamento em paralelo em unidades gráficas. Os resultados obtidos para os problemas foram comparados com outros trabalhos da literatura, mostrando boa concordância para os primeiros quatro problemas estudados. Para a cavidade ventilada, diferenças relativas de até 15.7% no coeficiente de troca de calor e de até 28.38% para o coeficiente de queda de pressão adimensional foram observadas. Análises a respeito dos termos de erros do método apresentado, e a utilização de outras metodologias com método de Lattice Boltzmann, como por exemplo, o emprego de outros operadores de colisão, para trazerem mais estabilidade e precisão, podem elucidar melhor as divergências observados entre o trabalho presente e outros trabalhos da literatura. / Lattice-Boltzmann Method (LBM) has gained attention over last decades due to its performance in solving complex flows such as multiphase and multicomponent flow, porous media and magnetohydrodynamics. There are also further techniques which makes LBM able to solve advection-difussion problems, which allows coupling this methodology to solve Navier-Stokes-Fourier equations. In this work, initial goals are, in a few words, studying main concepts required to understand numerical method origins from kinectic thery, and studying the method implemetantion to solve 2D fluid dynamic and thermal problems. Numerical implemetation was written in C, CUDA C and Matlab languages, keeping in focus five different cases of laminar incompressible flows in steady state: viscous Burgers\' equation, thermal Poiseuille, natural convection in square cavities, natural, forced and mixed convection in a lid driven cavity, and, finally, forced convection in a ventilated cavity, with one inlet and outlet ports. Besides that, a quick study regarding impact in simulation time of three distinct approaches was conducted. First approach consists in implementing a serial code, the second in using interpolation for coarser grids results as initial condition for finer meshes, and the last one is adding parallelized code implementation. Time gains between first and second approach range from 1.5 to 6, while parallelized code was able to converge from 20 to 25 times faster than second approach, confirming great benefits in using graphics processing units. Results obtained from numerical solutions of problems were compared with other works from literature, and a good agreement among them was observed, specially in the first four problems studied. In ventilated cavity problem, relative differences up to 15.7% in heat transfer coefficient and up to 28.38% in dimensionless pressure drop coefficient were observed. A further error terms analysis of method used in this work, and use of distinct approaches, such as different collision operators, in order to increase numerical solution stability and accurarcy, may shed a light on results divergences observed between this work and others from literature.

Page generated in 0.1155 seconds