• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 527
  • 119
  • 70
  • 61
  • 54
  • 35
  • 35
  • 35
  • 35
  • 35
  • 35
  • 15
  • 9
  • 8
  • 7
  • Tagged with
  • 1085
  • 1085
  • 430
  • 368
  • 205
  • 172
  • 93
  • 84
  • 83
  • 76
  • 73
  • 73
  • 71
  • 68
  • 67
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
421

Avaliação da conversão da resina composta polimerizada com luz halógena e LED com espectometria do infravermelho /

Sarabia Quiroz, Ana María. January 2004 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Welingtom Dinelli / Banca: Camilo Anauate Netto / Resumo: O presente estudo avaliou a conversão da polimerização de resinas compostas expostas à luz halógena e LED. Foram realizados corpos de prova e divididos em 64 grupos experimentais, onde variaram o tipo de luz (halógena e LED) utilizada, tempo de exposição à luz (20 e 40 segundos), profundidade do corpo de prova (1,2,3,e 4mm) e tempo de avaliação após a irradiação (0, 24,48 e 168 horas após a irradiação), cada grupo tinha cinco repetições. Os corpos de resina foram cortados e armazenados em ambiente seco e escuro. Foram confeccionadas pastilhas com 5mg de KBr e 50æg de pó de resina e os picos de absorbância foram registrados com o espectrômetro de infravermelho (FTIR). Os valores de conversão foram determinados na proporção das áreas obtidas com Microcal Origin 6.0 de C=O (pico em 1720) / C=C (pico em 1638). Os resultados da conversão foram analisados estatisticamente com os testes de ANOVA e Tukey. Obtendo-se, os seguintes resultados: A luz Halógena dá melhores resultados de polimerização que o LED, 40 segundos de exposição a luz dá melhores resultados de conversão, independente do tipo de luz, a menor profundidade o valor de conversão é melhor as 168 horas, que as observadas as 24 e 0 horas. Concluindo-se, que a conversão de polimerização das resinas compostas está influenciada pela fonte de luz, tempo de exposição à luz, profundidade do corpo de prova e tempo de avaliação. / Abstract: The purpose of this study was to determine the polymerization conversion of the resin-composites exposed to halogen light and LED. Five specimens were made for each of the 64 groups, varying type of light (halogen and LED), time of exposure (40 and 20 seconds) deepness of the specimen (1, 2, 3 and 4mm) and time of the evaluation (0, 24, 48 and 168 hours after light irradiation) .The specimens were stored in a dry and dark area and were pulverized into a fine powder with a mortar and a pestle. Fifty æg of powder were mixed with approximately 5mg of potassium bromide, and the absorbance peaks were recorded by FTIR. The value of conversion was determined from the ratio of areas obtained with Microcal Origin 6.0 of C=O (peak at 1720) /C=C (peak at 1638). The results were statistically analyzed with ANOVA and Tukey tests. The results observed were the following: i) halogen light gives better polymerization results than LED light, ii) 40 seconds to light exposure give s better results of conversion, iii) as less deepness , more is the conversion (with both types of light) , iv) With 168 hours of observation, the polymerization is better than with 0 or 24 hours of observation. Conclusion: polymerization conversion of the resin composites is influenced by the type of light, time of exposure to light, deepness of the specimen and time of observation. / Mestre
422

Construção e adequação de uma bancada de ensaios para investigações de técnicas não destrutivas de detecção de falhas incipientes em rolamentos

Alegranzi, Selvino Bork January 2012 (has links)
O monitoramento de vibração de máquinas rotativas é de grande interesse da indústria, uma vez que se tem a possibilidade de detectar, com certa antecedência, problemas relacionados à condição de funcionamento do equipamento, possibilitando reparos, ajustes ou consertos e, assim, minimizando custos no caso de falhas graves ou paradas inesperadas. Neste trabalho é feita a adequação de uma bancada de testes para estudo de técnicas de detecção de falhas em rolamentos de esferas por análise de vibração. O objetivo é o de localizar falhas em rolamentos utilizando o monitoramento dos sinais das vibrações (aceleração) no mancal que suporta o rolamento de teste e o posterior processamento com o auxílio de alguma técnica de detecção. Neste trabalho a técnica do envelope foi escolhida. A bancada, assim desenvolvida, permite a retirada e colocação dos rolamentos em estudo de maneira simples e rápida, permitindo a execução de diversos testes com rapidez. A investigação da detecção de falhas em rolamentos é feita comparando-se rolamentos em condições normais com rolamentos que têm um defeito induzido. Inicialmente é apresentada a descrição das origens e formas de propagação das falhas em elementos de rolamentos e também as formas como estas falhas são induzidas em locais específicos de cada rolamento. Uma breve revisão sobre métodos de detecção de falhas no domínio do tempo e da frequência é feita. Ênfase é dada ao método do envelope que faz uso da transformada de Hilbert (Hilbert Transform) conjuntamente com a transformada Rápida de Fourier (Fast Fourier Transform). Em seguida, descreve-se como foram geradas as falhas e separados os grupos de teste, também é descrito como os ensaios foram executados com os danos induzidos em local pré-determinado no rolamento. Os resultados obtidos possibilitaram identificar as origens das falhas induzidas tanto na pista externa quanto na interna dos rolamentos analisando os sinais de vibração do mancal onde está montado o rolamento em teste com o pós-processamento dos mesmos com a técnica investigada. Os testes simulam as condições extremas encontradas em sistemas rotativos de equipamentos industriais através da imposição de cargas verticais ao rolamento. Este estudo de detecção das falhas em rolamentos propiciou uma melhor compreensão e análise do processo de falha nestes componentes. / The vibration monitoring of rotating machines is of great interest to industries since it has the ability to detect, in advance, problems related to the operational condition of the equipment, enabling fixing, adjustments or repair, and thus, minimizing the cost in case of faults or unexpected downtime. In this work, the study of the adequacy of a test bench for detecting faults in ball bearings by vibration analysis techniques is developed. It aims at locating faults in ball bearings using vibration monitoring signals (acceleration) in the journal bearings that support this elements and further processing with the aid of some detection technique. In this work the envelope technique was chosen. The developed test bench thus allows the removal and placement of the bearings in a simple and fast way allowing running quickly several tests. The investigation of detecting faults in ball bearings is made by comparing the bearings under normal conditions with bearings which have an induced defect. First of all is presented a description of the origins and forms of propagation of faults in bearing elements and also the ways in which these failures are induced in specific locations of each bearing. A brief review of methods for detecting faults in the time and frequency domain is made. Emphasis is given to the Envelope Method which uses the Hilbert Transform with the Fast Fourier Transform. Then it is described how the tests were accomplished with the induced damage in predetermined sites in the bearing. The results obtained allowed to identify the origins of the induced bearing failures in both outer and inner races just by reading the vibration signals and post-processing them with the investigated technique. The tests take care to simulate conditions close to those found in actual rotatory systems of industrial equipment by imposing vertical loads to the bearing. This study in detecting flaws in balls bearings provided a better understanding of the analysis failure process in these components.
423

Avaliação dos métodos de espectroscopia Raman, de espectroscopia de absorção de infravermelho e testes de nanodureza para o estudo de cones de guta-percha / Evaluation of gutta-percha through Raman spectroscopy, fourier transform infrared and hardness tests

Vaucher, Alessandra Tolfo Ledur January 2013 (has links)
O objetivo deste estudo foi avaliar os métodos de espectroscopia Raman e espectroscopia de absorção de infravermelho (FTIR) na identificação da degradação do trans-1,4-poliisopreno de cones de guta-percha sem uso, e o comportamento do material após diferentes períodos decorridos de sua fabricação por testes de indentação de nanodureza (IHT). Para a análise, foram selecionadas 27 amostras de cones de guta-percha sem uso, de 5 marcas comerciais vendidas no mercado brasileiro, cedidas por Cirurgiões-dentistas. As amostras foram avaliadas através de espectroscopia Raman, com base no sinal da ligação C=C, indicando a presença de trans-1,4-poliisopreno; FTIR, levando-se em consideração a ligação C=O, indicativa de oxidação do material; IHT, avaliando-se rigidez e módulo de elasticidade. Os dados foram analisados de maneira descritiva. Observam-se, nos espectros de Raman, amostras nas quais os picos relativos à ligação C=C foram identificados, bem como outras em que não foi percebido o referido pico, sem uma relação direta com os tempos decorridos da fabricação dos cones de guta-percha sem uso. Em relação ao FTIR, em todas as amostras analisadas foram observados picos relativos à ligação C=O, indicando haver algum grau de oxidação no material. Os testes de nanodureza, realizados em cones sem uso, mostraram não haver homogeneidade dos valores de dureza e módulo de elasticidade. A análise pelos métodos de espectroscopia Raman e FTIR em cones de guta-percha é dificultada pelos vários componentes presentes no material e a separação do polímero trans-1,4-poliisopreno pode evitar número excessivo de picos e facilitar a interpretação dos espectros. Espectroscopia Raman e FTIR são capazes de identificar a degradação do poliisopreno. A presença, ou não, da ligação C=C, nos espectros de Raman, não teve relação direta com a idade dos cones. Os cones de guta-percha sem uso apresentaram algum grau de degradação, devido à presença da oxigênio no polímero. As análises de nanodureza não foram conclusivas quanto ao comportamento do material relacionado ao envelhecimento. / The aim of the present study was to evaluate the methods Raman spectroscopy and infrared absorption spectroscopy (FTIR) to analyze the degradation of trans-1,4-polyisoprene polymer in gutta-percha points, before use. Mechanical properties were assessed through the instrumented hardness tests (IHT). Twenty-seven samples of gutta-percha cones collected before use, belonging to five different commercial brands sold in Brazil, were obtained from Dental Surgeons. The samples were evaluated by Raman spectroscopy, based on the sign of the C=C bond (representing the trans-1,4-polyisoprene polymer); FTIR, considering the C=O bond (indicating polymer oxidation), and instrumented hardness tests (IHT), to assess both rigidity and elasticity modulus. Descriptive analysis was performed. Raman spectra showed that there were samples of gutta-percha before use where the C=C was identified, an others no. There was no relation between its detection and the time from manufacturing. FTIR showed C=O bond in all samples, indicating that there was some degree of oxidation on the material. Nanoindentation tests showed no homogeneity between hardness and modulus of elasticity. The analysis by Raman and FTIR in gutta-percha points is difficult because there are several components that form the material, and polymer isolation can facilitate the interpretation of the spectra. Both methods were able to evaluate polymers’ degradation. The presence of C=C bond, in Raman spectra, have no relation to their age. The gutta-percha points showed some degree of degradation, due to the presence of oxygen in the polymer. Nanoindentation tests did not provid conclusive results regarding the material’s aging behavior.
424

Projeto e construção de sistema de aquisição e processamento de dados para espectroscopia por transformada rápida de Fourier / Project and building of data acquisition system for fast Fourier transform spectrometer.

Walter Soto Encinas Junior 03 April 1995 (has links)
No presente trabalho procurou-se desenvolver um sistema computacional para a automação de um Espectrofotômetro de Varredura Refrativa. Este sistema é baseado em um computador hospedeiro da linha IBM-PC, que pode ser de qualquer modelo, desde que possua barramento ISA de 16 bits. O sistema se divide em dois módulos - aquisição e processamento. O modulo de aquisição e capaz de atingir taxas de aquisição de ate 200 KHz, com resolução de 12 bits. É independente de controle do hospedeiro pois possui lógica de controle e sistema de armazenamento próprio. O módulo de processamento envolve o uso de um processador vetorial de sinais digitais ZORAN ZR34161 dedicado a efetuar eficientemente a Transformada Rápida de Fourier (FFT). Também opera independentemente do computador hospedeiro. Este módulo é capaz de efetuar a FFT em um vetor real de 4096 pontos em 19,64 ms / This work was intended to develop a computational system to control a fast Fourier spectrophotometer. This system is based in an IBM-PC type host computer, with ISA bus 16 bits wide. The system has two modules - acquisition and processing. The acquisition module works at 200 KHz sample rate, with 12 bits of resolution, and also works without host control, due to its own memory system and control logic. The processing module uses a ZORAN ZR34161 vector signal processor, dedicated to do the Fast Fourier Transform (FFT) in the most efficient way. No management of host is required, and it can compute a FFT of a 4096 points real vector in 19,64 ms
425

Construção e adequação de uma bancada de ensaios para investigações de técnicas não destrutivas de detecção de falhas incipientes em rolamentos

Alegranzi, Selvino Bork January 2012 (has links)
O monitoramento de vibração de máquinas rotativas é de grande interesse da indústria, uma vez que se tem a possibilidade de detectar, com certa antecedência, problemas relacionados à condição de funcionamento do equipamento, possibilitando reparos, ajustes ou consertos e, assim, minimizando custos no caso de falhas graves ou paradas inesperadas. Neste trabalho é feita a adequação de uma bancada de testes para estudo de técnicas de detecção de falhas em rolamentos de esferas por análise de vibração. O objetivo é o de localizar falhas em rolamentos utilizando o monitoramento dos sinais das vibrações (aceleração) no mancal que suporta o rolamento de teste e o posterior processamento com o auxílio de alguma técnica de detecção. Neste trabalho a técnica do envelope foi escolhida. A bancada, assim desenvolvida, permite a retirada e colocação dos rolamentos em estudo de maneira simples e rápida, permitindo a execução de diversos testes com rapidez. A investigação da detecção de falhas em rolamentos é feita comparando-se rolamentos em condições normais com rolamentos que têm um defeito induzido. Inicialmente é apresentada a descrição das origens e formas de propagação das falhas em elementos de rolamentos e também as formas como estas falhas são induzidas em locais específicos de cada rolamento. Uma breve revisão sobre métodos de detecção de falhas no domínio do tempo e da frequência é feita. Ênfase é dada ao método do envelope que faz uso da transformada de Hilbert (Hilbert Transform) conjuntamente com a transformada Rápida de Fourier (Fast Fourier Transform). Em seguida, descreve-se como foram geradas as falhas e separados os grupos de teste, também é descrito como os ensaios foram executados com os danos induzidos em local pré-determinado no rolamento. Os resultados obtidos possibilitaram identificar as origens das falhas induzidas tanto na pista externa quanto na interna dos rolamentos analisando os sinais de vibração do mancal onde está montado o rolamento em teste com o pós-processamento dos mesmos com a técnica investigada. Os testes simulam as condições extremas encontradas em sistemas rotativos de equipamentos industriais através da imposição de cargas verticais ao rolamento. Este estudo de detecção das falhas em rolamentos propiciou uma melhor compreensão e análise do processo de falha nestes componentes. / The vibration monitoring of rotating machines is of great interest to industries since it has the ability to detect, in advance, problems related to the operational condition of the equipment, enabling fixing, adjustments or repair, and thus, minimizing the cost in case of faults or unexpected downtime. In this work, the study of the adequacy of a test bench for detecting faults in ball bearings by vibration analysis techniques is developed. It aims at locating faults in ball bearings using vibration monitoring signals (acceleration) in the journal bearings that support this elements and further processing with the aid of some detection technique. In this work the envelope technique was chosen. The developed test bench thus allows the removal and placement of the bearings in a simple and fast way allowing running quickly several tests. The investigation of detecting faults in ball bearings is made by comparing the bearings under normal conditions with bearings which have an induced defect. First of all is presented a description of the origins and forms of propagation of faults in bearing elements and also the ways in which these failures are induced in specific locations of each bearing. A brief review of methods for detecting faults in the time and frequency domain is made. Emphasis is given to the Envelope Method which uses the Hilbert Transform with the Fast Fourier Transform. Then it is described how the tests were accomplished with the induced damage in predetermined sites in the bearing. The results obtained allowed to identify the origins of the induced bearing failures in both outer and inner races just by reading the vibration signals and post-processing them with the investigated technique. The tests take care to simulate conditions close to those found in actual rotatory systems of industrial equipment by imposing vertical loads to the bearing. This study in detecting flaws in balls bearings provided a better understanding of the analysis failure process in these components.
426

Hidroxiapatita sintetica nanoestruturada e esmalte dental aquecidos e irradiados por laser de Er, Cr:YSGG. Caracterizacao por FTIR e por DRX / Nanostructured synthetic hydroxyapatite and dental enamel heated e irradiated by Er,Cr:YSGG. Characterized by FTIR and XRD

RABELO NETO, JOSE da S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:11Z (GMT). No. of bitstreams: 0 / Este estudo procurou avaliar as mudanças físicas e/ou químicas que ocorrem na hidroxiapatita (HAP) sintética e na presente no esmalte dental sob ação de aquecimento térmico em forno ou irradiação com o laser de Er,Cr:YSGG (2,79 m). Busca-se obter variações em sua estrutura a fim de torná-los mais resistentes à desmineralização, visando e prevenir a formação da cárie dental. A HAP sintética foi produzida pela reação das soluções de Ca(NO3) e (NH4)2HPO4 com controle de temperatura e pH. O esmalte foi coletado do dentes bovinos e triturados. As amostras em pó de HAP sintética e esmalte foram submetidas a aquecimento térmico em forno nas temperaturas de 200 °C, 400 °C, 600 °C, 800 °C e 1000 °C. Foram feitas irradiações laser com 5,79 J/cm2, 7,65 J/cm2, 10,55 e 13,84 J/cm2 para a HAP sintética e de 7,53 J/cm2, 10,95 J/cm2 e 13,74 J/cm2 para o esmalte. As amostras foram avaliadas por difração de raios-X(DRX) para análise das fases cristalográficas presentes e análise pelo método de Rietveld para comprovação destas fases cristalográficas e determinação de respectivas proporções no material. Foram obtidos também as variações de parâmetros de rede da cela unitária (eixo-a, eixo-c e volume), tamanho dos cristalitos e taxas de ocupações dos sítios dos átomos de Ca e P de ambos os materiais. As amostras foram ainda analisadas por espectroscopia de absorção no infravermelho por transformada de Fourier (FTIR), que mostrou as variações composicionais ocasionadas pelos tratamentos calculando-se as áreas das bandas referentes aos radicais carbonato, fosfato, água adsorvida e hidroxila. A termografia no infravermelho foi usada para medir a temperatura superficial gerada pelo feixe do laser nas amostras sólidas de esmalte. Com relação às fases cristalográficas presentes só foram encontradas além da fase majoritária de hidroxiapatita, as fases de fosfato de octacálcio (OCP) nas amostra de HAP sintética e tricálcio 9 fosfato da fase b (b -TCP) no esmalte aquecido a 800 °C. Apresentaram-se mudanças nos parâmetros de rede da cela unitária da HAP sintética e do esmalte, com diminuição do eixo-a, volume e tamanho dos cristalitos até as temperaturas entre 400 °C e 600 °C e também nas amostras irradiadas a laser. Acima da temperatura de 600 °C há o aumento destes parâmetros de rede. A relação Ca/P em todas as amostras sofreram diminuições, sendo que na amostra de esmalte irradiada a 7,53 J/cm2 apresentou Ca/P igual a 1,6817 e a irradiada a 13,74 J/cm2 apresentou Ca/P igual a 1,6831. A espectroscopia mostrou que os efeitos tanto do aquecimento como da irradiação laser podem ser observados principalmente nas bandas de carbonato, água adsorvida e hidroxila e que as mudanças da rede cristalográfica podem ser correlacionadas com substituições de carbonato em sítios de hidroxilas e fosfatos. Ambos os tratamentos causam também diminuição da concentração de carbonatos, sendo que este efeito ocorreu com maior intensidade nas irradiações a laser e houve ainda diminuição na quantidades de água adsorvida e hidroxilas. Todas estas alterações modificam as propriedades do material, como sua solubilidade e consequentemente influenciam na resistência à desmineralização de interesse para processos como prevenção da cárie dental e erosão dental. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
427

Efeitos nas caracteristicas fisico-quimicas, microbiologicas e sensoriais em amostras de mel de abelhas submetidas a radiacao gama / Effects on physicochemical, microbiological and sensory characteristics of honey bee samples submitted to gamma radiation

BERA, ALEXANDRE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:08Z (GMT). No. of bitstreams: 0 / A produção de mel no Brasil tem aumentado consideravelmente e vem ganhando destaque no mercado internacional, consequentemente muitas exigências passaram a fazer parte da cadeia produtiva apícola. Além das análises previstas na legislação brasileira, o mercado externo procura produtos que atendam aos mais rigorosos padrões de qualidade. O mel possui características interessantes devido a sua constituição, porém, existem problemas que podem alterar seu padrão de identidade e qualidade. A aplicação da radiação gama é uma proposta viável que promove a diminuição da carga microbiana sem alterar a constituição e as características físico-químicas, com perdas nutricionais menores quando comparada a outros tratamentos usados em alimentos. Neste estudo, além dos parâmetros físico-químicos exigidos pela legislação brasileira (MAPA), também foram incluídas outras análises pertinentes, inclusive a técnica de espectroscopia no infravermelho com transformada de Fourier (FTIR-ATR). As análises microbiológicas foram realizadas nas amostras de méis puros, nas quais, posteriormente, foram inoculadas cargas microbianas conhecidas para avaliar a ação da radiação gama nas doses de 5 e 10 kGy. O teste triangular foi utilizado na análise sensorial para diferenciar as amostras não-irradiadas das irradiadas. As maiores modificações nas amostras de méis foram, principalmente, nas concentrações de HMF (hidroximetilfurfural) e na atividade diastásica, ocorrendo diminuição significativa em todas as amostras analisadas. Houve redução na carga microbiana a partir da aplicação da dose de 5 kGy, atingindo a ausência com a aplicação de 10 kGy de dose, com exceção do Paenibacillus larvae que mostrou ser mais resistente. A análise sensorial realizada nas amostras de mel e mel irradiado, com doses de 5, 10 e 15 kGy, apontou não haver diferença significativa (5%) entre as amostras controle e irradiadas. A aplicação da radiação gama em méis mostrou ser um método muito útil na descontaminação microbiológica, apresentando poucas alterações no produto com doses de até 10 kGy. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
428

Estudo da reparação óssea por espectroscopia ATR-FTIR após remoção de fragmento da região mandibular com laser de Er, Cr:YSGG ou broca multilaminada / Study of bone repair ATR-FTIR spectroscopy technique after the removal of a fragment from jaw region using Er, Cr:YSGG laser or drill

BENETTI, CAROLINA 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T12:16:48Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T12:16:48Z (GMT). No. of bitstreams: 0 / A reparação óssea é um fator crítico para o sucesso de procedimentos odontológicos e ortopédicos que necessitem do corte ósseo, sendo desejado que esta ocorra de forma rápida e eficaz. Uma maior compreensão da reparação óssea em um nível estrutural e molecular é o primeiro passo para o desenvolvimento de técnicas de corte e terapias regenerativas. Neste contexto, a técnica de FTIR possibilita obter informações sobre a estrutura e composição de tecido mineralizado. O principal objetivo deste projeto foi verificar a eficácia da espectroscopia FTIR na caracterização de diferentes estágios da reparação óssea após a realização de remoção óssea utilizando duas ferramentas de corte: o laser de Er,Cr:YSGG ou uma broca carbide multilaminada, em alta rotação. Foi realizada a remoção de dois fragmentos ósseos da mandíbula de 30 coelhos, e o processo de reparação óssea foi estudado imediatamente, 3, 7, 15, 21, e 28 dias após o procedimento cirúrgico. Utilizou-se a técnica de espectroscopia FTIR para a aquisição das imagens espectrais dos diferentes estágios de reparação, e foi analisada a proporção entre os compostos do tecido utilizando as bandas de amidas, colágeno, carbonato e fosfato dos espectros de absorção. Também foi realizada a análise histológica dos mesmos estágios de reparação estudados. A técnica de espectroscopia FTIR se mostrou eficaz na caracterização do processo de reparação óssea. Observou-se uma tendência de aumento na proporção de compostos orgânicos até o Grupo 15D, após o qual houve aumento na proporção de compostos inorgânicos indicando maior mineralização após este período. Os resultados da análise histológica mostraram diferenças nos primeiros estágios de reparação entre o corte ósseo com o laser de Er,Cr:YSGG e a broca em alta rotação. Essas diferenças não foram detectadas na espectroscopia FTIR com as técnicas de análise utilizadas. Ainda assim, os resultados obtidos mostraram que a técnica de espectroscopia FTIR foi sensível às alterações de conteúdo orgânico no processo de reparação do tecido ósseo, podendo auxiliar com o desenvolvimento de novas técnicas e ferramentas para melhorar a eficiência deste processo. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
429

Processamento e caracterização de material compósito polimérico obtido com nanotubo de carbono funcionalizado / Processing and characterization of polymeric composite material obtained with functionalized carbon nanotube

LEBRAO, GUILHERME W. 17 March 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-03-17T10:45:40Z No. of bitstreams: 0 / Made available in DSpace on 2015-03-17T10:45:40Z (GMT). No. of bitstreams: 0 / Desenvolveu-se neste trabalho um procedimento para incorporação de nanotubos de carbono (NTC) em uma resina fenol / epóxi a ser utilizado como matriz de um compósito de fibra de carbono. Realizando para tal, a oxidação dos NTC com o uso de micro-ondas e sua funcionalização com 3-amino-propil-tri-etoxi-silano, usado com agente de acoplamento entre a resina e o NTC. Após o processamento, como resultado da adição dos NTC na resina, obteve-se um aumento na sua temperatura de transição vítrea e uma melhora no limite de resistência à flexão e impacto. No material compósito fibra de carbono, obtido por laminação manual, onde a resina fenol / epóxi mais NTC foi usada como matriz, obteve-se o aumento do limite de resistência à tração e ao impacto, confirmado por uma análise de variância com 95% de confiança, mostrando a eficácia no tratamento dos NTC. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
430

Influencia do tipo de fonte de luz, tempo e distancia de fotoativação sobre o grau de conversão de diferentes sistemas adesivos / Effect of light-curing unit, light attenuation and exposure time on the degree of conversion of various adhesive systems

Voltarelli, Fernanda Regina 15 August 2018 (has links)
Orientador: Giselle Maria Marchi Baron / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T22:38:37Z (GMT). No. of bitstreams: 1 Voltarelli_FernandaRegina_D.pdf: 2059748 bytes, checksum: 5c76919f1c67fc154dd391b4ba4d28b4 (MD5) Previous issue date: 2010 / Resumo: O objetivo do presente estudo foi avaliar o efeito do tipo de fonte de luz (Lâmpada Halógena/HAL; Diodos emissores de luz/ LED), da distância de fotoativação (2, 4 e 6 mm) e do tempo de exposição (10, 20, 40 e 60s) sobre o grau de conversão (%) de cinco sistemas adesivos comerciais (Excite/EX; Adesivo de cobertura do sistema Clearfil Protect Bond /PB; Clearfil S3 Bond/S3; Single Bond Plus/SB; Adesivo de cobertura do sistema Scotchbond Multipurpose/SBMP). Cento e cinquenta amostras dos sistemas adesivos foram distribuídas em 30 grupos (n= 5) de acordo com o sistema adesivo, fonte de luz e distância da ponteira. Amostras de 3 µl foram gotejadas sobre um cristal de seleneto de zinco e, o grau de conversão/GC mensurado através de espectrofotômetro infravermelho por transformada de Fourier equipado com dispositivo de reflectância total atenuada (faixa espectral entre 1500-1800 cm-1; resolução de 8.0 cm-1; velocidade de deslocamento de 2,8 mm/s). Para EX, S3 e SB, jatos de ar foram aplicados durante 20s para auxiliar a evaporação do solvente. Imagens dos espectros obtidos antes da polimerização e imediatamente após completados os determinados tempos de exposição foram utilizadas para o cálculo do GC. Os valores de GC para distância e tempo de exposição foram analisados através de análise de variância para medidas repetidas no tempo com a metodologia PROC MIXED (?= 5%). Para EX e S3, HAL resultou em melhor grau de conversão em todos os tempos e distância de fotoativação. Quando fotoativados com HAL, SBMP, SB e PB demonstraram melhor grau de conversão a partir de 40s de fotoativação. Para S3, melhor grau de conversão foi observado após 20s de fotoativação. Quando fotoativados com LED, SBMP, SB e PB demonstraram melhor grau de conversão a partir de 20s de fotoativação. Para S3 melhor grau de conversão foi observado com o tempo máximo de fotoativação (60s). Para EX o efeito do tempo de fotoativação variou de acordo com a distância da ponta polimerizadora. Todas as variáveis (fonte de luz, distância e tempo de exposição) foram capazes de influenciar os valores de GC. Entretanto, tempos de exposição prolongados resultaram em significante melhoria do GC obtido para todos os sistemas adesivos testados. / Abstract: The aim of the present study was to evaluate the effect of the type of light curing unit (Halogen Lamp/HAL; Light Emitting Diodes/LED), of the light curing distance (2, 4 and 6 mm) and of the light curing exposure time (10, 20, 40 e 60s) on the degree of conversion (%) of five commercial adhesive systems (Excite/EX; Bond component from Clearfil Protect Bond /PB; Clearfil S3 Bond/S3; Single Bond Plus/SB; Bond component from Scotchbond Multipurpose/SBMP). Hundred and fifty samples were allocated into 30 groups (n = 5) according to the type of adhesive system, light curing unit and the distance from the light unit end point. Adhesive system samples of 3 ?l were dropped on the top of a zinc selenide crystal and the degree of conversion/DC was measured using Fourier Transform Infrared Spectroscopy equipped with Attenuated Total Reflectance attachment (spectral range between 1500-1800 cm-1; resolution of 8.0 cm-1; crosshead speed of 2.8 mm/s). For EX, S3 and SB, air drying streams for 20s were used to help solvent evaporation. Spectral images obtained before polymerization and immediately after each light curing exposure time were used for DC determination. DC values for the light curing distance and exposure time were analyzed using repeated measure ANOVA with PROC MIXED methodology (?= 5%). For EX and S3, HAL has shown improved degree of conversion for all light exposure times and for all light curing distances. When light cured with HAL, SBMP, SB and PB have shown improved degree of conversion following 40s of light curing exposure time. For S3, improved degree of conversion was observed after 20s of light curing exposure time. When light cured with LED, SBMP, SB and PB have shown improved degree of conversion following 20s of light curing exposure time. For S3, improved degree of conversion was observed with the ultimate light curing exposure time (60s). For EX, the effect of light curing exposure time varied according to the distance of the light curing end point. All variables (light curing unit, light curing distance and exposure time) were able to influence the DC values. However, longer exposure times resulted in significant improvement of the DC of all adhesive systems tested in this study. / Doutorado / Dentística / Doutor em Clínica Odontológica

Page generated in 0.0961 seconds