• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 37
  • 37
  • 36
  • 20
  • 20
  • 13
  • 12
  • 11
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da fadiga por rotação em instrumentos rotatórios exploratórios com diferentes tratamentos térmicos de níquel-titânio(NITI)

Viana, Luiz Carlos Trevia Morais Correia 14 July 2017 (has links)
Made available in DSpace on 2019-03-30T00:26:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2017-07-14 / Introduction: The aim of the present study was to compare the cyclic fatigue resistance of rotary pathfinding instruments made of nickel-titanium (NiTi) alloys submitted to different heat-treatments. Methods: Eighty NiTi endodontic files were used. The study groups were composed of Scout Race 15.02 (FKG Deintaire SA), Pathfile 19.02 (Dentsply Maillefer, Ballaigues, Switzerland), Proglider 16.02 (Dentsply Maillefer, Ballaigues, Switzerland), and Hyflex GPS 20.02 (Coltène Whaledent, Allstatten, Switzerland) instruments, which were subjected to cyclic fatigue testing using simulated canals with 6 mm radius and 30° and 45° curvature angles. The data obtained were organized in an Excel spreadsheet and analyzed statistically using BioEstat 5.3 software (Marimauá Institute, Manaus, Brazil). The nonparametric Kruskal-Wallis test was used for... and the Mann-Whitney U-test was used for multiple comparisons, at a significance level of 5%. Results: The Hyflex instrument was superior to all the other instruments (p < 0.05), and Pathfile had a superior fatigue time (p < 0.05) compared to Scout Race and Proglider, for both curvature angles analyzed. No significant difference was observed between Scout Race and Proglider. Conclusion: Cyclic fatigue resistance of the HyFlex GPF instrument was the highest among the instruments tested, and the curvature had a significant effect on fatigue resistance. A significant decrease in the time of cyclic fatigue was observed with an increase in flexion (curvature angle),irrespective of the instrument analyzed. / O presente estudo propôs a comparação da resistência da fadiga por rotação em limas exploratórias rotatórias com diferentes tratamento térmicos de níquel-titânio(NITI). Metodologia: Para conduzir esse experimento, foram utilizadas 80 limas endodônticas de NITI. Foram escolhidas as limas: Scout Race 15.02 (FKG Deintaire SA), Pathfile 19.02 (Dentsply Maillefer, Ballaigues, Suíça), Proglider 16.02 (Dentsply Maillefer, Ballaigues, Suíça), Hyflex GPS 20.02 (Coltène Whaledent, Allstatten, Suíça). Os grupos foram submetidos ao teste de fadiga cíclica através de dispositivos que simulam raio de 6 mm e ângulos de curvatura de 30° e 45°. Todas as limas foram acionadas até que ocorresse a fratura visual das mesmas, sendo o tempo entre o início de funcionamento até a fratura de cada instrumento protocolado através de um cronômetro 1/100 segundos e tabulado, registrado por apenas um avaliador. Os dados obtidos foram organizados em planilhas de Excel e analisados estatisticamente com o auxílio do software BioEstat 5.3(Instituto Marimauá, Manaus, Brasil). Tendo em vista as diferenças significativas entre os resultados dos grupos, foi utilizado o teste não-paramétrico Kruskal-Wallis. O teste U de Mann-Whitney foi utilizado para comparações múltiplas, utilizando-se o nível de significância de 5%. Resultados: De acordo com os resultados analisados, pode-se notar que o aumento da flexão(angulação) promoveu significativa diminuição do tempo de fadiga cíclica, independentemente do grupo analisado(p<0,05). O instrumento Hyflex obteve resultado superior em relação aos demais, independentemente da flexão sob análise. Na sequência, em ambas as flexões analisadas, o instrumento Pathfile apresentou tempo de fadiga superior(p <0.05) em relação aos instrumentos Scout Race e Proglider. Os instrumentos Scout Race e Proglider não apresentaram diferenças estatisticamente significativas entre si. Conclusão: A lima Hyflex GPF apresentou, estatisticamente, maior resistência à fadiga cíclica em comparação com as outras limas utilizadas na metodologia, independente do grau de curvatura utilizado. Houve uma diminuição significativa no tempo de fadiga cíclica com o aumento do ângulo da curvatura.
2

Avaliação da resistência à fratura de dentes tratados endodonticamente restaurados com pinos dentários e com pinos de fibras de polietileno / Evaluation of Fracture Resistance of Endodontically Treated Teeth Reconstructed with Dentinal Post and Cores and Polyethylene Woven Fiber Ribbon Post and Cores

Kaizer, Osvaldo Bazzan 05 May 2003 (has links)
Avaliou-se a resistência à fratura de dentes tratados endodonticamente reconstruídos com pinos de fibras de polietileno e com pinos dentários. Para tal, selecionaram-se 60 caninos superiores humanos seccionados na junção cementoesmalte, tratados endodonticamente (condutos desobturados até a profundidade de 8mm) e fixados em blocos de resina acrílica. Distribuíram-se os corpos de prova aleatoriamente em quatro grupos de 15 unidades: 1) preparo convencional dos condutos e confecção de pinos de fibras de polietileno; 2) preparo convencional dos condutos e pinos dentários; 3) condutos medianamente alargados e pinos dentários; 4) condutos amplamente alargados e pinos dentários. Nos grupos 1 e 2, dilataram-se os condutos até a broca Largo de número 4; nos grupos 3 e 4, os condutos sofreram desgastes seqüenciais padronizados, simulando raízes medianamente ou amplamente destruídas. No grupo 4, a espessura das paredes do conduto no terço cervical era de 0,5mm. Realizou-se a cimentação dos pinos com sistema adesivo Scotchbond Multi-Uso Plus e cimento resinoso Enforce. Construiu-se a porção coronária dos núcleos com resina composta autopolimerizável reforçada com titânio Ti-Core. Armazenaram-se os espécimes por 24 horas em água destilada, submetendo-os então aos testes de resistência à fratura sob compressão na máquina de ensaios universal Kratos, até falha do sistema. A força de compressão foi de 100 kgf e a velocidade de 0,5mm/min, sendo aplicada em ângulo de 135° em relação ao longo eixo da raiz. Os valores de resistência à fratura encontrados foram, em ordem decrescente: Grupo 3 - 58,67kgf; Grupo 2 - 3,30kgf; Grupo 4 - 47,91kgf; Grupo 1 - 45,46kgf, sendo que a análise estatística (ANOVA e Tukey) demonstrou diferença estatisticamente significante somente entre os grupos 1 e 3. Em relação ao padrão de fratura, observou-se: Grupo 1 – ampla predominância de fratura da porção coronária do núcleo; Grupo 2 e Grupo 3 – padrão variado de fraturas (tanto radiculares como do pino e/ou porção coronária); Grupo 4 – todas as raízes fraturaram. / Fracture resistance of endodontically treated teeth reconstructed with polyethylene woven fiber ribbon post and cores and dentinal post and cores has been evaluated. For that purpose, 60 human maxillary canines were selected, cut on the cementoenamel junction, endodontically treated (non- filled canal to a depth of 8mm)and fixed in acrylic resin blocks. The specimens were randomly distributed in 4 groups of 15 units each: 1) conventional canal preparation and making of polyethylene woven fiber ribbon post and cores; 2) conventional preparation of canals and dentinal post and cores; 3) fairly flared canals and dentinal post and cores; 4) greatly flared canals and dentinal post and cores. On groups 1 and 2, canals were enlarged as much as number 4 Largo bur; on groups 3 and 4, canals were subjected to standardized sequential cutting to permit a simulation of fairly or greatly flared roots. On group 4, the width of canal walls on the gingival third was 0.5mm. Post cementation was performed with the use of Scotchbond Multi-Purpose Plus bonding agent and Enforce resin cement. The core was built with self-curing composite reinforced with Ti-Core titanium. Specimens were stored in distilled water for 24 hours and subsequently subjected to compression fracture resistance tests on the Kratos universal testing machine until system failure. Load of 100kgf was applied at a speed of 0.5mm/min at an 135° angle in relation to the long axis of the root. Fracture resistance under compression presented the following values (in decreasing order): 1) group 3 – 58.67kgf; 2) group 2 – 53.30kgf; 3) group 4 – 47.91kgf; 4) group 1 – 45.46kgf. Results were subjected to statistical analysis (ANOVA and Tukey),which only showed significant statistical difference between groups 1 and 3. As to the patterns of failure, the figures observed were: group 1 - 86.6% on the post and/or core; group 2 - 46.6% on the gingival third of the root and an equal figure for post and/or core; group 3 - 40% on the gingival third of the root and 53.3% on the post and/or core; group 4 - 66% on the gingival third of the root and 33.3% on the middle third of the root.
3

Avaliação da resistência à fratura de dentes tratados endodonticamente restaurados com pinos dentários e com pinos de fibras de polietileno / Evaluation of Fracture Resistance of Endodontically Treated Teeth Reconstructed with Dentinal Post and Cores and Polyethylene Woven Fiber Ribbon Post and Cores

Osvaldo Bazzan Kaizer 05 May 2003 (has links)
Avaliou-se a resistência à fratura de dentes tratados endodonticamente reconstruídos com pinos de fibras de polietileno e com pinos dentários. Para tal, selecionaram-se 60 caninos superiores humanos seccionados na junção cementoesmalte, tratados endodonticamente (condutos desobturados até a profundidade de 8mm) e fixados em blocos de resina acrílica. Distribuíram-se os corpos de prova aleatoriamente em quatro grupos de 15 unidades: 1) preparo convencional dos condutos e confecção de pinos de fibras de polietileno; 2) preparo convencional dos condutos e pinos dentários; 3) condutos medianamente alargados e pinos dentários; 4) condutos amplamente alargados e pinos dentários. Nos grupos 1 e 2, dilataram-se os condutos até a broca Largo de número 4; nos grupos 3 e 4, os condutos sofreram desgastes seqüenciais padronizados, simulando raízes medianamente ou amplamente destruídas. No grupo 4, a espessura das paredes do conduto no terço cervical era de 0,5mm. Realizou-se a cimentação dos pinos com sistema adesivo Scotchbond Multi-Uso Plus e cimento resinoso Enforce. Construiu-se a porção coronária dos núcleos com resina composta autopolimerizável reforçada com titânio Ti-Core. Armazenaram-se os espécimes por 24 horas em água destilada, submetendo-os então aos testes de resistência à fratura sob compressão na máquina de ensaios universal Kratos, até falha do sistema. A força de compressão foi de 100 kgf e a velocidade de 0,5mm/min, sendo aplicada em ângulo de 135° em relação ao longo eixo da raiz. Os valores de resistência à fratura encontrados foram, em ordem decrescente: Grupo 3 - 58,67kgf; Grupo 2 - 3,30kgf; Grupo 4 - 47,91kgf; Grupo 1 - 45,46kgf, sendo que a análise estatística (ANOVA e Tukey) demonstrou diferença estatisticamente significante somente entre os grupos 1 e 3. Em relação ao padrão de fratura, observou-se: Grupo 1 – ampla predominância de fratura da porção coronária do núcleo; Grupo 2 e Grupo 3 – padrão variado de fraturas (tanto radiculares como do pino e/ou porção coronária); Grupo 4 – todas as raízes fraturaram. / Fracture resistance of endodontically treated teeth reconstructed with polyethylene woven fiber ribbon post and cores and dentinal post and cores has been evaluated. For that purpose, 60 human maxillary canines were selected, cut on the cementoenamel junction, endodontically treated (non- filled canal to a depth of 8mm)and fixed in acrylic resin blocks. The specimens were randomly distributed in 4 groups of 15 units each: 1) conventional canal preparation and making of polyethylene woven fiber ribbon post and cores; 2) conventional preparation of canals and dentinal post and cores; 3) fairly flared canals and dentinal post and cores; 4) greatly flared canals and dentinal post and cores. On groups 1 and 2, canals were enlarged as much as number 4 Largo bur; on groups 3 and 4, canals were subjected to standardized sequential cutting to permit a simulation of fairly or greatly flared roots. On group 4, the width of canal walls on the gingival third was 0.5mm. Post cementation was performed with the use of Scotchbond Multi-Purpose Plus bonding agent and Enforce resin cement. The core was built with self-curing composite reinforced with Ti-Core titanium. Specimens were stored in distilled water for 24 hours and subsequently subjected to compression fracture resistance tests on the Kratos universal testing machine until system failure. Load of 100kgf was applied at a speed of 0.5mm/min at an 135° angle in relation to the long axis of the root. Fracture resistance under compression presented the following values (in decreasing order): 1) group 3 – 58.67kgf; 2) group 2 – 53.30kgf; 3) group 4 – 47.91kgf; 4) group 1 – 45.46kgf. Results were subjected to statistical analysis (ANOVA and Tukey),which only showed significant statistical difference between groups 1 and 3. As to the patterns of failure, the figures observed were: group 1 - 86.6% on the post and/or core; group 2 - 46.6% on the gingival third of the root and an equal figure for post and/or core; group 3 - 40% on the gingival third of the root and 53.3% on the post and/or core; group 4 - 66% on the gingival third of the root and 33.3% on the middle third of the root.
4

Avaliação da resistência à fratura de dentes com condutos alargados e reconstruídos com pinos de fibras de vidro pré-fabricados (associados a pinos acessórios ou fitas de fibras) ou com pinos anatômicos / Evaluation of fracture resistance of teeth with flared root canals reconstructed with prefabricated glass fiber posts (associated with accessory posts or fiber strips) or with anatomic posts

Kaizer, Osvaldo Bazzan 06 June 2006 (has links)
Avaliou-se a resistência à fratura de dentes tratados endodonticamente e reconstruídos com núcleos metálicos fundidos ou com diferentes procedimentos restauradores empregando pinos de fibras de vidro. Selecionaram-se 50 dentes caninos seccionados na junção cemento-esmalte, tratados endodonticamente e fixados em blocos de resina acrílica. Os dentes foram distribuídos aleatoriamente em cinco grupos, subdividididos de acordo com o tratamento instituído (10 espécimes cada): 1) núcleo metálico fundido com liga de Ni-Cr (grupo controle); 2) pino de fibras de vidro convencional FibreKor n° 2 (1,25mm de diâmetro); 3) pino de fibras de vidro envolvido por fitas de fibras de vidro (Interlig); 4) pino de fibras de vidro combinado com pinos acessórios de fibras de vidro (Reforpin); 5) pino anatômico (pino de fibras de vidro reembasado com resina composta de baixa viscosidade (Filtek Flow). O preparo do conduto nos cinco grupos simulou raízes com canais largos e foi executado de forma escalonada (dois degraus). Para este preparo, utilizou-se a ponta diamantada 1016HL (diâmetro de 1,8mm), que penetrou 10mm no conduto (profundidade total de preparo do conduto). A seguir, a ponta diamantada 3017HL (diâmetro de 2,5mm) penetrou 5mm no conduto. Realizou-se a cimentação dos pinos com sistema adesivo Scotchbond Multi-Uso Plus e cimento resinoso RelyX CRA. Coroas totais metálicas fundidas em liga de Níquel-Cromo foram cimentadas sobre a porção coronária de todos os espécimes. Os espécimes foram armazenados por 24 horas em água destilada a 37°C e submetidos ao teste de resistência à fratura sob compressão na máquina de ensaios universal Kratos. A carga foi aplicada em ângulo de 135° com o longo eixo da raiz, na velocidade de 0,5mm/min. Os valores de resistência à fratura encontrados foram, em ordem decrescente: Grupo 1 ? 110,85kgf; Grupo 4 - 93,88kgf; Grupo 5 ? 89,34kgf; Grupo 3 - 79,07kgf; Grupo 2 - 76,04kgf, sendo que a análise estatística (ANOVA e Tukey) demonstrou diferença estatisticamente significativa (p < 0,05) entre o grupo 1 e o grupo 2, bem como entre o grupo 1 e o grupo 3. Em relação ao padrão de fratura, observou-se: grupo 1 ? todas as raízes fraturaram (60% no terço médio); grupo 2 e grupo 4 - 40% de fraturas no terço cervical da raiz e 30 a 40% de falhas da porção coronária do núcleo; grupo 3 ? predominância de fraturas no terço cervical da raiz (60%); grupo 5 ? 50% das falhas na porção coronária do núcleo. / This study evaluated the fracture resistance of endodontically treated teeth reconstructed with cast metallic posts or different restorative procedures using glass fiber posts. Fifty canines were sectioned at the cementoenamel junction, endodontically treated and fixated in acrylic resin blocks. Teeth were randomly divided into five groups (10 specimens each): 1) cast metallic post (control group); 2) conventional glass fiber post FibreKor n. 2 (1.25mm diameter); 3) glass fiber post surrounded by glass fiber strips (Interlig); 4) glass fiber post combined with accessory glass fiber posts (Reforpin); 5) anatomic post (glass fiber post covered with low-viscosity composite resin (Filtek Flow). Root canal preparation in the five groups simulated roots with wide root canals and was performed by the step-down technique (two steps). This preparation was performed with a diamond bur n. 1016HL (1.8-mm diameter), which penetrated into the root canal in 10mm (total depth of root canal preparation). The cervical step was prepared with 5-mm depth with a diamond bur n. 3017HL (2.5-mm diameter). Posts were luted with the adhesive system Scotchbond Multi-Uso Plus and resin cement RelyX CRA. After fabrication of the coronal portion of posts (standardized with aid of polypropylene templates) with composite resin Enforce-Core, a metallic full crown cast in nickel-chromium alloy was cemented on it. Specimens were stored in distilled water at 37ºC for 24 hours and submitted to compressive fracture resistance test in a universal testing machine Kratos. Load was applied at 135° to the root long axis, at a crosshead speed of 0.5mm/min. Fracture resistance values were the following, in decreasing order: Group 1 ? 110.85kgf; Group 4 ? 93.88kgf; Group 5 ? 89.34kgf; Group 3 ? 79.07kgf; Group 2 ? 76.04kgf; statistical analysis (ANOVA and Tukey) revealed statistically significant difference (p < 0.05) between groups 1 and 2 and between groups 1 and 3. Concerning the pattern of fracture, all roots in group 1 presented fracture (60% at the middle third); groups 2 and 4 presented 40% of fractures at the cervical root third and 30 to 40% of failure at the coronal portion of the post; group 3 demonstrated predominance of fracture at the cervical root third (60%); in group 5, 50% of failures occurred at the coronal portion of the post
5

Avaliação da resistência à fratura de dentes tratados endodonticamente com pinos pré-fabricados e resinas compostas variando a quantidade de remanescente dentário coronal / Fracture strength assessment of teeth endodontically treated, restored with prefabricated posts and compound resins, and varying amount of remaining coronal dental structure

Melo, Murilo Pereira de 17 February 2003 (has links)
O objetivo desta pesquisa foi avaliar a influência do remanescente dentário coronal de dentes tratados endodonticamente, restaurados com pinos pré-fabricados e duas resinas como núcleos de preenchimento, uma de presa dual (Enforce Core) e outra fotopolimerizável (Z-250). Foram utilizados 40 caninos superiores humanos extraídos, divididos em quatro grupos de 10 espécimes: Grupo l – com remanescente dentário coronal de 3mm e restaurados com Enforce Core; Grupo ll – com remanescente dentário coronal de 3mm e restaurado com Z-250; Grupo III – sem remanescente dentário coronal e restaurado com Enforce Core; Grupo IV – sem remanescente dentário coronal e restaurado com Z-250. Após restaurados, os dentes foram levados a uma Máquina de Ensaio Universal e submetidos a uma força de compressão à 45º até que ocorresse fratura da restauração. A análise dos resultados (ANOVA, p>0,05) mostrou não haver diferença estatisticamente significativa entre os dentes com e sem remanescente dentário coronal. Com relação ao material utilizado para o preenchimento coronário, constatou-se diferença significativa, sendo que os valores mais elevados de resistência à fratura foram encontrados no grupo restaurado com a resina fotopolimerizável. / The aim of this study was to evaluate the remaining coronal dental structure influence of endodontically treated teeth, restored with prefabricated posts and two different types of resin filling cores, a dual cure resin (Enforce Core) and a photopolymerizing resin (Z-250). 40 extracted upper canine human teeth were used, divided into four groups of 10 specimens each: Group I – with coronal dental structure of 3mm restored with Enforce Core; Group II – with coronal dental structure of 3mm restored with Z-250; Group III – without any remaining coronal dental structure restored with Enforce Core; Group IV – without any remaining coronal dental structure restored with Z-250. After the complete restoration, the teeth were taken to a universal test machine, and then submitted to compression forces at 45º, until reaching the fracture of the restoration. The analysis of the results (ANOVA, p>0,05) showed no statistically significant difference between the teeth with or without coronal dental structure. In relation to the material used for the coronal filling, there has been a statistically significant difference. Higher fracture strength values were found in the group restored with photopolymerizing resin.
6

Avaliação da resistência à fratura por compressão de infraestruturas de próteses fixas de três elementos (1º pré-molar a 1º molar) confeccionadas com cerâmicas IPS Empress II e In-Ceram

Mendes, Vagner 27 March 2003 (has links)
O apelo estético tem obrigado as indústrias de materiais odontológicos e os pesquisadores a buscar materiais que apresentem, além da estética, resistência suficiente para resistir às forças mastigatórias. Assim o objetivo deste trabalho foi comparar a resistência à fratura por compressão axial de infraestruturas de próteses fixas de três elementos (1º pré-molar a 1º molar) confeccionadas com dois sistemas de porcelanas, In-Ceram Zircônia e IPS Empress 2. Foram selecionados 20 pré-molares e 20 molares que receberam preparos tipos “inlays" com caixas oclusais e proximais (DO nos pré-molares e MO nos molares), tendo-se o cuidado de obter caixas proximais com 4,0 mm de altura por 4,0 mm de largura. Após obtenção dos modelos em gesso, as infraestruturas foram confeccionadas em laboratórios credenciados pelos fabricantes de acordo com o protocolo determinado para cada material. A cimentação foi feita com o cimento Variolink II. Após a cimentação, as infraestruturas foram submetidas a teste de carga por compressão pela ação de uma ponta de aço com 2,0 mm de diâmetro, em uma máquina de ensaio universal, numa velocidade de 0,5 mm/min. Os resultados mostraram uma superioridade estatisticamente significante (p = 0,025) da porcelana Empress 2 (86,68 Kgf) em relação à porcelana In-Ceram Zircônia (67,87 Kgf), e não foi encontrada correlação estatística entre as medidas das áreas de conexão com os valores máximos de carga. O modo de fratura mostrou que em todos os corpos de prova de Empress 2 e em seis corpos de prova de In-Ceram a fratura ocorreu no sentido oblíquo se estendendo da região onde a carga foi aplicada até a área de conexão. Três corpos de prova de In-Ceram fraturam verticalmente na área de conexão e um corpo de prova fraturou-se verticalmente na região do pôntico sem ocorrer danos à área de conexão. / The aesthetic appeal has influenced the dental materials industries and the researchers to develop materials that present, besides the aesthetics, enough resistance to oclusal forces. Thus, the aim of this research was to compare the compressive fracture strength of IPS Empress 2 and In-Ceram Zirconia of frameworks of three unit resin-bonded fixed partial denture. Forty natural extracted teeth (twenty maxilar first premolars and twenty molars) were selected and received inlay preparations, according to the ceramic manufacturer´s directions. The frameworks were made by two experimented technicians, and cemented with Variolink II. The axial compressive load was conducted in a universal testing machine at a cross-head speed of 0,5 mm/min. The results showed a statistical significant superiority (p = 0,025) of the Empress 2 (105,30 Kgf) regarding to In-Ceram (101,68 Kgf). It wasn't found statistical correlation between measures of the connection areas and maximum values. All Empress 2 and six In-Ceram frameworks showed a similar mode of fracture extending obliquely from the region where the load was applied until the connection area. Three In-Ceram framewoks fractured vertically at the connection area and one was fractured vertically at the pontic area.
7

Influência do acesso endodôntico minimamente invasivo na localização dos canais radiculares, eficácia da instrumentação e resistência à fratura de molares superiores

Rover, Gabriela January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2017. / Made available in DSpace on 2017-10-24T03:17:36Z (GMT). No. of bitstreams: 1 347976.pdf: 1074094 bytes, checksum: de072b74bc727925f1792b4e2fdd7244 (MD5) Previous issue date: 2017 / Introdução: O acesso endodôntico minimamente invasivo (AEMI) prioriza a mínima remoção de dentina, com o intuito de elevar a resistência à fratura do elemento dental. O objetivo deste estudo foi analisar a influência do AEMI na localização dos canais radiculares, na eficácia da instrumentação e na resistência à fratura de molares superiores. Metodologia: Trinta primeiros molares superiores humanos foram selecionados por meio de imagens de microtomografia computadorizada (micro-CT) e divididos em dois grupos (n = 15) de acordo com a forma do acesso: acesso endodôntico tradicional, AET; e AEMI. Feito o acesso, a localização dos canais foi realizada em 3 etapas: 1, visão direta; 2, com auxílio de microscópio operatório (MO); 3, com auxílio de MO e desgastes com insertos ultrassônicos. Após a instrumentação dos canais com limas Reciproc, as amostras foram novamente escaneadas. A análise do volume dos canais foi realizada antes e após o preparo, e o percentual de debris acumulados após o preparo do canal. Para calcular o transporte do canal e centralização do preparo em 3 níveis (3, 5 e 7 mm do forame apical) as imagens pré e pós-instrumentação foram mensuradas utilizando o software ImageJ. Após a obturação dos canais e restauração das cavidades endodônticas, as amostras foram submetidas ao teste de resistência à fratura em uma máquina de testes universal (EMIC). Força de compressão contínua foiaplicada no sulco principal dos molares superiores em 30° no sentido do longo eixo do dente a uma velocidade de 1 mm/min. até que ocorresse a fratura. Os dados foram analisados pelos testes exato de Fisher, Shapiro-Wilk e t de student (p > 0.05). Resultados: No grupo AET, foi possível localizar todos os canais das amostras nas etapas 1-3 em 73,33%, 80% e 86,67% respectivamente, enquanto que no grupo AEMI, foi possível localizar todos os canais nas etapas 1-3 em 26,67%, 33,33% e 80% respectivamente. O AET localizou significativamente mais canais radiculares nas etapas 1 e 2 (p < 0,05). Não houve diferenças significativas no percentual de áreas não tocadas e no percentual de debris acumulados após a instrumentação entre os grupos testados. O AEMI transportou significativamente mais o canal palatino, a 7 mm do ápice (p < 0,05). O AET manteve o preparo do canal radicular mais centralizado no canal palatino a 5 e 7 mm do ápice (p < 0,05). O AEMI manteve o preparo do canal radicular mais centralizado no canal disto-vestibular, a 5 mm do ápice (p < 0,05). Não houve diferença na resistência a fratura entre o grupo AET (937,55 ± 347,25 N) e AEMI (996,30 ± 490,78 N) (p > 0,05). Conclusões: O AEMI comprometeu a localização dos canais radiculares nos primeiros molares superiores quando não foi utilizado microscópio operatório associado ao ultrassom. Essa forma de acesso pode influenciar negativamente na instrumentação do canal palatino nos molares superiores e não foi capaz de aumentar a sua resistência à fratura.<br> / Abstract : Introduction: Conservative endodontic cavity (CEC) recommends the minimum removal of dentin, in order to increase the fracture resistance of the dental element. This study assessed the influence of CEC on root canal detection, instrumentation efficacy and fracture resistance of maxillary molars. Methodology: Thirty human maxillary first molars were selected through micro-computed tomography (micro-CT) images, assigned to CEC or TEC (traditional endodontic cavities) groups (n = 15/group), and accessed accordingly. Root canal detection was carried out in three stages: 1, no magnification; 2, under operating microscope (OM); 3, under OM and ultrasonic wear. After instrumentation of the root canals with Reciproc files, the samples were scanned again. Canal volume analysis was performed before and after preparation, and percentage of debris after preparation. From pre- and post-instrumentation images, were analysed canal transportation and centring ratio at three cross-section levels (3, 5 and 7 mm from the apical end of the root) using ImageJ software. After root canal filling and cavities restoration, the samples were submitted to the fracture resistance test (FR) in the universal testing machine. A continuous compressive force was applied at the central fossa at 30° from the tooth long axis at 1 mm/min until failure occurred. Data were analyzed by the Fisher exact, Shapiro-Wilk and t-tests (a = 0.05). Results: In TEC group it was possible to locate all the root canals of the samples in stages 1, 2 and 3in 73.33%, 80% and 86.67%, respectively. In CEC group these percentages were 26.67%, 33.33% and 80%, respectively. TEC Located more root canals in stages 1 and 2 (p < 0.05). After preparation, the proportion of the untouched canal wall and accumulated debris were similar between the groups. Canal transportation was significantly higher in palatal canal at 7 mm from de apical end (p < 0.05). The preparation of the root canal was more centralized with the TEC in palatal canal at 5 and 7 mm from de apical end (p < 0.05), and with the CEC in disto-bucal canal at 5 mm from de apical end (p < 0.05). There was no difference in FR between the groups TEC (937.55 ± 347.25 N) and CEC (996.30 ± 490.78 N) (p > 0.05). Conclusion: CEC compromised the detection of the root canals in the maxillary molars when no ultrasonic associated OM was used. This cavity design had a negative influence on the instrumentation of the palatal canal and did not contribute to the increase of fracture resistance of the molars evaluated.
8

Detecção de fraturas radiculares por meio da tomografia computadorizada de feixe cônico em imagens reconstruídas com voxels diferentes aos de aquisição / Detection of root fractures by cone beam computed tomography images with variation of voxel reconstruction

Marchini, Monikelly do Carmo Nascimento, 1986- 18 August 2018 (has links)
Orientador: Solange Maria de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:47:58Z (GMT). No. of bitstreams: 1 Marchini_MonikellydoCarmoNascimento_M.pdf: 1171679 bytes, checksum: e017160a8fc47671be3a04ceeee1a993 (MD5) Previous issue date: 2011 / Resumo: O diagnóstico de fraturas radiculares longitudinais sem separação dos fragmentos é um grande desafio na prática clínica. Portanto, o objetivo neste trabalho foi avaliar a eficácia da Tomografia Computadorizada de Feixe Cônico (TCFC) na detecção de fraturas radiculares longitudinais e comparar as imagens adquiridas e reconstruídas com o mesmo voxel com as imagens reconstruídas com voxels menores aos de aquisição. Para realização desta pesquisa foram utilizados 40 dentes humanos posteriores extraídos que foram instrumentados com o sistema rotatório K3. As fraturas obtidas se caracterizaram por serem incompletas e sem separação dos fragmentos, sendo realizadas em uma máquina de ensaio universal (Instron 4411), com a introdução de uma ponta cônica com força controlada aplicada na entrada dos canais. Para aquisição das imagens, os dentes foram posicionados em uma mandíbula macerada e escaneados em um aparelho de TCFC antes e após a realização das fraturas. As imagens foram adquiridas utilizando-se 3 protocolos com tempos de aquisição de 10, 20 e 40 segundos e valores de voxel de 0,4; 0,3; e 0,25mm, respectivamente. Depois de reconstruídas em um mesmo voxel (0,25mm), foram avaliadas nos três planos de corte (axial, coronal e sagital) por 3 avaliadores. Após a análise estatística de Mc Nemar e curva ROC, foi observado que não houve diferença estatisticamente significante entre as imagens adquiridas/reconstruídas com valores de voxel de 0,4/0,25mm(p= 0,0022), 0,3/0,25mm (p= 0,0056) e 0,25/0,25mm (p= 0,0005). A sensibilidade (50%, 55% e 70%), especificidade (90%, 90% e 100%) e acurácia (70%, 72,5% e 85%) aumentaram de acordo com a diminuição do valor do voxel adquirido. Conclui-se que a TCFC mostrou-se eficaz no diagnóstico de fraturas radiculares longitudinais e que as imagens reconstruídas com voxels menores aos de aquisição diminuíram a sensibilidade e a especificidade em relação às imagens adquiridas e reconstruídas com o mesmo voxel, porém estatisticamente não obtiveram diferenças significantes entre si na detecção dessas fraturas / Abstract: Longitudinal root fractures diagnosis with no separation of the fragments is a greater challenge in clinical practice. Therefore, the aim of this study was to evaluate the effectiveness of Cone Beam Computed Tomography (CBCT) in the detection of longitudinal root fractures and to compare the images acquired and reconstructed with the same voxel in the reconstructed images with the smaller acquisition voxels. For this study, 40 extracted human posterior teeth were instrumented with K3 rotary system. The fractures obtained were characterized by incompleteness and without separation of the fragments, being held in a universal testing machine (Instron 4411) with the introduction of a conical tip with controlled force applied inside the root. For image acquisition, the teeth were placed in a dry mandible and scanned on a CBCT device before and after the fractures. Images were acquired with 3 protocols for acquisition times of 10, 20 and 40 seconds, voxel values of 0.4 mm, 0.3 mm and 0.25 mm, respectively. After reconstructed in the same voxel (0.25 mm) were evaluated in three planes (axial, coronal and sagital) for 3 observers. After statistical McNemar analysis and ROC curve was observed that there was no statistically significant difference between images acquired/reconstructed with voxel values of 0.4/0,25 mm (p = 0.0022), 0.3/0,25 mm (p = 0.0056) and 0.25/0,25 mm (p = 0.0005). The sensitivity (50%, 55% and 70%), specificity (90%, 90% and 100%) and accuracy (70%, 72.5% and 85%) increased according to the declining value of the acquired voxel. It could be concluded the CBCT proved to be effective in the diagnosis of longitudinal root fractures and that the images reconstructed with the smaller acquisition voxels decreased sensitivity and specificity regarding the images acquired and reconstructed with the same voxel, but had no statistically significant differences each other in detecting these fractures / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
9

Avaliação da resistência à fratura de dentes tratados endodonticamente com pinos pré-fabricados e resinas compostas variando a quantidade de remanescente dentário coronal / Fracture strength assessment of teeth endodontically treated, restored with prefabricated posts and compound resins, and varying amount of remaining coronal dental structure

Murilo Pereira de Melo 17 February 2003 (has links)
O objetivo desta pesquisa foi avaliar a influência do remanescente dentário coronal de dentes tratados endodonticamente, restaurados com pinos pré-fabricados e duas resinas como núcleos de preenchimento, uma de presa dual (Enforce Core) e outra fotopolimerizável (Z-250). Foram utilizados 40 caninos superiores humanos extraídos, divididos em quatro grupos de 10 espécimes: Grupo l – com remanescente dentário coronal de 3mm e restaurados com Enforce Core; Grupo ll – com remanescente dentário coronal de 3mm e restaurado com Z-250; Grupo III – sem remanescente dentário coronal e restaurado com Enforce Core; Grupo IV – sem remanescente dentário coronal e restaurado com Z-250. Após restaurados, os dentes foram levados a uma Máquina de Ensaio Universal e submetidos a uma força de compressão à 45º até que ocorresse fratura da restauração. A análise dos resultados (ANOVA, p>0,05) mostrou não haver diferença estatisticamente significativa entre os dentes com e sem remanescente dentário coronal. Com relação ao material utilizado para o preenchimento coronário, constatou-se diferença significativa, sendo que os valores mais elevados de resistência à fratura foram encontrados no grupo restaurado com a resina fotopolimerizável. / The aim of this study was to evaluate the remaining coronal dental structure influence of endodontically treated teeth, restored with prefabricated posts and two different types of resin filling cores, a dual cure resin (Enforce Core) and a photopolymerizing resin (Z-250). 40 extracted upper canine human teeth were used, divided into four groups of 10 specimens each: Group I – with coronal dental structure of 3mm restored with Enforce Core; Group II – with coronal dental structure of 3mm restored with Z-250; Group III – without any remaining coronal dental structure restored with Enforce Core; Group IV – without any remaining coronal dental structure restored with Z-250. After the complete restoration, the teeth were taken to a universal test machine, and then submitted to compression forces at 45º, until reaching the fracture of the restoration. The analysis of the results (ANOVA, p>0,05) showed no statistically significant difference between the teeth with or without coronal dental structure. In relation to the material used for the coronal filling, there has been a statistically significant difference. Higher fracture strength values were found in the group restored with photopolymerizing resin.
10

Avaliação da resistência à fratura por compressão de infraestruturas de próteses fixas de três elementos (1º pré-molar a 1º molar) confeccionadas com cerâmicas IPS Empress II e In-Ceram

Vagner Mendes 27 March 2003 (has links)
O apelo estético tem obrigado as indústrias de materiais odontológicos e os pesquisadores a buscar materiais que apresentem, além da estética, resistência suficiente para resistir às forças mastigatórias. Assim o objetivo deste trabalho foi comparar a resistência à fratura por compressão axial de infraestruturas de próteses fixas de três elementos (1º pré-molar a 1º molar) confeccionadas com dois sistemas de porcelanas, In-Ceram Zircônia e IPS Empress 2. Foram selecionados 20 pré-molares e 20 molares que receberam preparos tipos “inlays” com caixas oclusais e proximais (DO nos pré-molares e MO nos molares), tendo-se o cuidado de obter caixas proximais com 4,0 mm de altura por 4,0 mm de largura. Após obtenção dos modelos em gesso, as infraestruturas foram confeccionadas em laboratórios credenciados pelos fabricantes de acordo com o protocolo determinado para cada material. A cimentação foi feita com o cimento Variolink II. Após a cimentação, as infraestruturas foram submetidas a teste de carga por compressão pela ação de uma ponta de aço com 2,0 mm de diâmetro, em uma máquina de ensaio universal, numa velocidade de 0,5 mm/min. Os resultados mostraram uma superioridade estatisticamente significante (p = 0,025) da porcelana Empress 2 (86,68 Kgf) em relação à porcelana In-Ceram Zircônia (67,87 Kgf), e não foi encontrada correlação estatística entre as medidas das áreas de conexão com os valores máximos de carga. O modo de fratura mostrou que em todos os corpos de prova de Empress 2 e em seis corpos de prova de In-Ceram a fratura ocorreu no sentido oblíquo se estendendo da região onde a carga foi aplicada até a área de conexão. Três corpos de prova de In-Ceram fraturam verticalmente na área de conexão e um corpo de prova fraturou-se verticalmente na região do pôntico sem ocorrer danos à área de conexão. / The aesthetic appeal has influenced the dental materials industries and the researchers to develop materials that present, besides the aesthetics, enough resistance to oclusal forces. Thus, the aim of this research was to compare the compressive fracture strength of IPS Empress 2 and In-Ceram Zirconia of frameworks of three unit resin-bonded fixed partial denture. Forty natural extracted teeth (twenty maxilar first premolars and twenty molars) were selected and received inlay preparations, according to the ceramic manufacturer´s directions. The frameworks were made by two experimented technicians, and cemented with Variolink II. The axial compressive load was conducted in a universal testing machine at a cross-head speed of 0,5 mm/min. The results showed a statistical significant superiority (p = 0,025) of the Empress 2 (105,30 Kgf) regarding to In-Ceram (101,68 Kgf). It wasn't found statistical correlation between measures of the connection areas and maximum values. All Empress 2 and six In-Ceram frameworks showed a similar mode of fracture extending obliquely from the region where the load was applied until the connection area. Three In-Ceram framewoks fractured vertically at the connection area and one was fractured vertically at the pontic area.

Page generated in 0.1596 seconds