• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 186
  • 33
  • 15
  • 11
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 294
  • 294
  • 40
  • 34
  • 29
  • 29
  • 27
  • 25
  • 25
  • 24
  • 23
  • 23
  • 18
  • 17
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Caracterização de espelhos para telescópios Cherenkov / Mirror characterizing for Cherenkov telescopes

Dipold, Jessica 10 February 2015 (has links)
Raios γ são bilhões de vezes mais energéticos do que fótons visíveis. Através da observação do céu deste tipo de radiação, é possível estudar fenômenos como a emissão de pulsares, explosões de super-novas e buracos negros, assim como os gamma ray bursts, um dos maiores mistérios da astrofísica moderna. A principal técnica utilizada em observações astrofísicas de chuveiros de raios gama é a de Telescópios Cherenkov, que podem reconstruir a trajetória dos raios γ durante sua passagem pela atmosfera observando sua emissão de radiação Cherenkov. Existem diversos experimentos bem-sucedidos em funcionamento, tais como o VERITAS, MAGIC e HESS. Em 2006 um novo observatório foi proposto, com sensibilidade uma ordem de magnitude melhor do que qualquer outro experimento atual. O Cherenkov Telescope Array (CTA) está em fase de protótipo e consistirá de dezenas de telescópios Cherenkov com tamanhos diferentes, o que possibilitará observações em muitas regiões do espectro de raios-gama. O local onde o Observatório será construído ainda não foi decidido e dependerá de várias características geográficas para fazê-lo, sendo uma das mais importantes o tempo observável, que deve ser maior que 80% para ser considerado um possível sítio. Um dos locais propostos está localizado no norte da Argentina, próximo a cidade de San Antonio de los Cobres (SAC). Para demonstrar a funcionalidade deste sítio, desenvolvemos um espaço nele para testarmos propriedades ópticas e mecânicas de quatro protótipos de espelhos, além de suas condições de condensação. Três espelhos hexagonais de Vidro/Alumínio, com 1.5 metro de base a base, e um circular de Vidro/Dielétrico, com 0.5 metro de diâmetro, todos esféricos com posição focal entre 15 e 16 metros, foram expostos às condições ambientais de SAC entre Maio/2013 até Junho/2014. Para testar a variação de suas propriedades mecânicas e ópticas devido à exposição ao meio ambiente, dois testes foram feitos. Para verificar se a curvatura e a suavidade da superfície do espelho permaneceram constantes, desenvolvemos um equipamento no Instituto de Física de São Carlos que media a posição 2f do espelho, onde a imagem formada é a menor possível, e sua Função Ponto Espalhada (PSF), o tamanho da imagem feita pelo espelho de uma fonte pontual. A posição focal de todos os espelhos foi estável, enquanto a PSF mostrou pequena variação com o tempo de exposição. Para analisar a variação da cobertura de Alumínio (ou Dielétrico) dos espelhos, nós medimos a variação de sua refletividade através de um espectrômetro portátil fabricado pela OceanOptics, que mostrou que a cobertura dielétrica é mais estável do que as de alumínio, que tiveram pouca variação entre 300-400 nm na maioria dos espelhos. E, finalmente, para testar a qualidade de ambos espelho e sítio em relação ao tempo de observação, calculamos o tempo de condensação de dois espelhos durante o período de Dezembro/2013 até Abril/2014. Isso foi feito através de fotos automáticas de cada espelho tiradas remotamente durante a noite, fornecendo dados para observar mudanças diárias na qualidade da superfície dos espelhos assim como a condensação durante esse período. Um espelho de Vidro/Alumínio e um de Vidro/Dielétrico foram testados, ambos mostrando resultados similares de aproximadamente 20% de tempo condensado, estando no limite de 80% de tempo observacional mencionado anteriormente. Através destes testes, pretendemos criar uma técnica para o cálculo do tempo de condensação em qualquer sítio proposto. / γrays are billions of times more energetic than visible photons. Through the sky observation of this kind of radiation, it is possible to study phenomena like the emission from pulsars, supernova explosions and black holes, as well as gamma-ray bursts, one of the greatest mysteries in modern astrophysics. The main technique used in astrophysical observations in γrays showers is the Imaging Cherenkov Telescope, which can image the trajectory of gamma-rays during its passage through the atmosphere by observing its emission of Cherenkov radiation. There are several successful experiments currently functioning, such as VERITAS, MAGIC and HESS. In 2006, a new observatory was proposed, which will have a sensitivity one order of magnitude better than any of the existing experiments. The Cherenkov Telescope Array (CTA) is in its prototype phase, and will consist of several tens of Cherenkov telescopes with different sizes, which will allow observation in many different regions of the γray spectrum. The site where the Observatory will be constructed is not yet decided and it depends on several geographic characteristics, being one of the most important the observable time, which must be above 80% to be considered as a possible site. One of the proposed sites is located in the north of Argentina, close to the city of San Antonio de los Cobres (SAC). In order to demonstrate the functionality of the site, we developed a facility on it to test the optical and mechanical properties of four prototype mirrors, as well as their condensation conditions. Three Glass/Aluminum hexagonal mirrors, 1.5 meters flat-to-flat diameter, and one Glass/Dielectric circular mirror, 0.5 meters diameter, all spherical with a focal position between 15 and 16 meters, were exposed to the environmental conditions of SAC from May/2013 until June/2014. To test their mechanical and optical properties variation because of the environment exposition, two different tests were made. In order to verify if the curvature and smoothness of the mirrors remained constant, we developed an equipment at the Instituto the Física de São Carlos that could measure the 2f position, where the image formed by the mirror is the smallest as possible, and its Point Spread Function (PSF), the size of the image made by the mirror by a punctual source. The focal position of all mirrors was proven to be stable, while the PSF size showed small differences according to the exposure time. To examine the variation of the Aluminum (or Dielectric) covering of the mirrors we measured its reflectivity variation through a portable spectrometer fabricated by OceanOptics, which showed that the dielectric covering is more stable than the Aluminum ones, even though all of them showed a constant reflectivity in the 300-400 nm range. And finally, to test both the mirror and the site quality in observation time, we calculated the condensed time of two mirrors during the period of December/2013 until April/2014. This was done through automatic pictures of each mirror taken remotely during the night, providing data to observe daily changes in the quality of the mirror surfaces as well as if there is condensation during that period. A Glass/Aluminum mirror and the Glass/Dielectric one were tested, both showing very similar results of around 20% condensed time, being in the limit of the 80% of observational time forementioned. Through these tests, we intend to provide a technique for the calculation of condensed time in any proposed site.
172

Estudo da função resposta de um detector cintilador de Nal(TI) / A Study on the Response Function of a NaI(Tl) Scintilation Detector

Villa, Marcelo Barros 17 March 2014 (has links)
O conhecimento preciso do espectro energético de fótons é de extrema importância na radioterapia no que se refere à escolha adequada das doses a que os pacientes são submetidos. Os dados de saída dos detectores de radiação são apenas espectros de altura de pulso (PHD), ao invés de espectros de energia, que correspondem a informações distorcidas sobre a fonte e seus decaimentos devido a diversos erros associados ao processo de cintilação do cristal e à eletrônica. Os resultados medidos foram obtidos com o uso de um detector cintilador de NaI(Tl) e as simulações Monte Carlo foram feitas com o uso do programa EGSnrc. A partir das características do detector obtidas experimentalmente, nossas simulações puderam ser validadas para se aproximarem o mais próximo possível do caso real em laboratório. Dessas medidas experimentais de fontes radioativas de calibração e simulações, foi montada uma matriz resposta inversa que transforma PHD em espectro de energia de fótons. Uma vez que a faixa energética das fontes radioativas medidas teve um limite de 1.6MeV, a matriz resposta também o apresenta, mas que pode ser contornado de acordo com a geometria usada para a obtenção do PHD a ser corrigido. Observa-se que a resposta do detector é diretamente proporcional à energia e assim, dependendo da energia incidente a ser estudada, dois tipos de matriz resposta inversa podem ser aplicadas. Os resultados desta transformação de PHD para espectro de energia de fótons são apresentados. / The accurate knowledge of the photon energy spectrum in radiotherapy is of extremely importance when it comes to the appropriate choice for doses whose patients are submitted. The output data from the radiation detectors is described as pulse high distributions, instead of energy spectra, that correspond to distorted information about the source and its decays due to many errors associated to the crystal scintillation process and the electronics. The measured results were obtained with a NaI(Tl) scintillation detector and Monte Carlo simulations were performed by the EGSnrc program. From the detector characteristics obtained experimentally, the simulations were validated so they could approximate the more real as possible as in laboratory. Using these simulated and experimental calibration sources, an inverse response matrix was built and transforms pulse high distributions in photons energy spectrum. Once the correction energy limit due to the radiation sources used is approximately 1.6 MeV, so the response matrix has a limit, but it can be overcame by the beam incident angle and the geometry used when the pulse high distributions to be corrected is going to be measured. One can realize that the detector response is directly proportional to the incident energy and, when it is intense as in a LINAC or weak as in a calibration source, different types of matrix can be applied. The results from these transformations are presented.
173

Estudo do efeito da radiação ionizante na utilização dos catalisadores desativados de craqueamento / Study of the effect of ionizing radiation for utilization of spent cracking catalysts

Kondo, Fernando Mantovani 09 December 2014 (has links)
Catalisador é uma substância que altera a velocidade de uma reação. Na indústria do petróleo os catalisadores mais utilizados são os catalisadores de Fluid Catalytic Cracking (FCC) e Hidrocatalytic Cracking (HCC) cada qual utilizado em uma determinada etapa do processo. Esses catalisadores são usados para facilitar a quebra das cadeias moleculares que darão origem a uma mistura de hidrocarbonetos. Contudo, o catalisador perde progressivamente sua atividade, seja pela mudança de sua estrutura molecular original ou pela sua contaminação provenientes de outras moléculas do petróleo. A aplicação das radiações ionizantes (feixe de elétrons e raios gama) nesses catalisadores desativados foi estudada para auxiliar na extração de metais ou terras-raras de alto valor agregado. Nos ensaios realizados com os catalisadores de FCC utilizaram-se das técnicas de irradiação por 60Co e por feixe de elétrons (EB) e tiveram como estudo a extração do lantânio (La2O3), a regeneração e utilização desses catalisadores. Entretanto, o uso da radiação ionizante não contribuiu nesses processos. Já nos catalisadores de HCC foi utilizado a irradiação por feixe de elétrons e como estudo a extração do molibdênio (MoO3). Na temperatura em torno de 750°C nesses catalisadores irradiados do leito inferior obteve-se um rendimento de extração duas vezes maior em comparação aos não irradiados, ou seja de 57,65% e 26,24% respectivamente. / Catalyst is a substance that changes the rate of a reaction. In the petroleum industry the commonly catalysts are used for Fluid Catalytic Cracking (FCC) and Hidrocatalytic Cracking (HCC), which one applied in a specific stage. These catalysts are used to facilitate the molecular chains cracking which will generate a mixture of hydrocarbons. However, the catalyst gradually loses its activity, either by changing its original molecular structure or by its contamination from other petroleum molecules. The application of ionizing radiation (electron beam and gamma rays) over these spent catalysts was studied to contribute with the extraction of metals or rare-earths of high added-value. Tests carried out with FCC catalysts were used the techniques of 60Co irradiation and electron beam (EB) and had as a subject the extraction of lanthanum (La2O3), regeneration and utilization of these catalysts. However, the use of ionizing radiation has not contributed in these processes. Meanwhile with HCC catalysts the irradiation used was electron beam and had as a subject the extraction of molybdenum (MoO3). In temperature around 750°C, these irradiated catalysts of the lower region have an extraction yield twice higher compared to non-irradiated ones, in other words 57.65% and 26.24% respectively.
174

Estudo do efeito da radiação ionizante na utilização dos catalisadores desativados de craqueamento / Study of the effect of ionizing radiation for utilization of spent cracking catalysts

Fernando Mantovani Kondo 09 December 2014 (has links)
Catalisador é uma substância que altera a velocidade de uma reação. Na indústria do petróleo os catalisadores mais utilizados são os catalisadores de Fluid Catalytic Cracking (FCC) e Hidrocatalytic Cracking (HCC) cada qual utilizado em uma determinada etapa do processo. Esses catalisadores são usados para facilitar a quebra das cadeias moleculares que darão origem a uma mistura de hidrocarbonetos. Contudo, o catalisador perde progressivamente sua atividade, seja pela mudança de sua estrutura molecular original ou pela sua contaminação provenientes de outras moléculas do petróleo. A aplicação das radiações ionizantes (feixe de elétrons e raios gama) nesses catalisadores desativados foi estudada para auxiliar na extração de metais ou terras-raras de alto valor agregado. Nos ensaios realizados com os catalisadores de FCC utilizaram-se das técnicas de irradiação por 60Co e por feixe de elétrons (EB) e tiveram como estudo a extração do lantânio (La2O3), a regeneração e utilização desses catalisadores. Entretanto, o uso da radiação ionizante não contribuiu nesses processos. Já nos catalisadores de HCC foi utilizado a irradiação por feixe de elétrons e como estudo a extração do molibdênio (MoO3). Na temperatura em torno de 750°C nesses catalisadores irradiados do leito inferior obteve-se um rendimento de extração duas vezes maior em comparação aos não irradiados, ou seja de 57,65% e 26,24% respectivamente. / Catalyst is a substance that changes the rate of a reaction. In the petroleum industry the commonly catalysts are used for Fluid Catalytic Cracking (FCC) and Hidrocatalytic Cracking (HCC), which one applied in a specific stage. These catalysts are used to facilitate the molecular chains cracking which will generate a mixture of hydrocarbons. However, the catalyst gradually loses its activity, either by changing its original molecular structure or by its contamination from other petroleum molecules. The application of ionizing radiation (electron beam and gamma rays) over these spent catalysts was studied to contribute with the extraction of metals or rare-earths of high added-value. Tests carried out with FCC catalysts were used the techniques of 60Co irradiation and electron beam (EB) and had as a subject the extraction of lanthanum (La2O3), regeneration and utilization of these catalysts. However, the use of ionizing radiation has not contributed in these processes. Meanwhile with HCC catalysts the irradiation used was electron beam and had as a subject the extraction of molybdenum (MoO3). In temperature around 750°C, these irradiated catalysts of the lower region have an extraction yield twice higher compared to non-irradiated ones, in other words 57.65% and 26.24% respectively.
175

Avaliação morfofuncional de pele humana conservada em glicerol e submetida à radiação gama: estudo em camundongos atímicos / Morphofunctional evaluation of human skin preserved in glycerol and exposed to gamma radiation: a study in athymic mice

Bringel, Fabiana de Andrade 27 April 2011 (has links)
Extensas lesões na pele expõem o organismo a uma série de agentes agressores, dificultando a reparação espontânea da pele e muitas vezes levando o paciente a óbito. Nesse caso, se não houver áreas doadoras de autoenxertos, pode se utilizar aloenxertos. Neste tipo de enxerto, os tecidos são processados em Bancos de Tecidos, onde se pode empregar a radiação ionizante como método de esterilização. De acordo com estudos in vitro, a radiação gama, em doses acima de 25 kGy, provoca desestruturação das fibrilas de colágeno I da derme conservada em glicerol na concentração de 85%, reduzindo significativamente a resistência à tração dos tecidos irradiados. Observações clínicas sugerem, ainda, integração mais rápida da derme humana, conservada em glicerol e submetida à radiação ionizante, com os tecidos do receptor, quando comparada à derme somente conservada em glicerol. Para verificar se essas alterações relatadas in vitro, comprometeriam o emprego in vivo, de amostras de pele humana, submetidas à radiação gama, foram realizados transplantes de peles humanas, irradiadas ou não, em camundongos Nude. A pele dos camundongos foi submetida à análise macroscópica, imagens de tomografia de coerência óptica, histologia e ensaios biomecânicos. Foi possível concluir que os enxertos irradiados a 25 kGy promoveram uma contração inicial maior, mas essa alteração não interferiu na dimensão da área final de reparação, ainda, os animais que receberam esses enxertos apresentaram mais rápido fechamento da ferida em comparação com os demais, além disso o emprego de enxertos irradiados (25 e 50 kGy) promoveu a formação de um processo de reparação mais organizado e sem efeitos significantes nas propriedades biomecânicas. / Extensive skin lesions expose the body to damaging agents, which makes spontaneous regeneration difficult and, in many cases, leads patient to death. In such cases, if there are no donating areas for autograft, allografts can be used. In this type of graft, tissue is processed in tissue banks, where it can be subjected to radiosterilization. According to in vitro studies, gamma radiation, in doses higher than 25 kGy, induces alterations in skin preserved in glycerol at 85%, reducing the tensile strength of irradiated tissue. Clinical observation also suggests faster integration of such graft with the receptors tissue. In order to assess if the alterations observed in vitro, would compromise in vivo use, transplants of human tissue, irradiated or not, were performed in Nude mice. The skin of the mice was subjected to macroscopic analysis, optical coherence tomography imaging, histological and biomechanical assays. It was possible to conclude that grafts irradiated with 25 kGy promoted greater initial contraction, without alteration of the final dimensions of the repair area, also displaying a faster closing of the wound. Moreover, the use of irradiated grafts (25 and 50 kGy) enabled the formation of a more organized healing process without significant effects on biomechanical properties.
176

66Ga como padrão de calibração de raios de altas energias para detectores HPGe / Ga66 as a standard for high energy gamma rays

Serra, André da Silva 20 May 2008 (has links)
Este trabalho trata do estudo da eficiencia de pico e fun¸cao resposta de detetores semicondutores do tipo HPGe na faixa de energia entre 2 a 5 MeV, um pouco acima da faixa de energia das fontes usualmente dispon´veis em espectroscopia . Ele faz parte de um projeto de calibra¸cao de detetores em altas energias (at´e 20 MeV). Os resultados serao utilizados na obten¸cao das intensidades das radia¸coes de rea¸coes foto-nucleares produzidas por meio do bremstrahlung do feixe de el´etrons de 38 MeV do acelerador Microton em constru¸cao. Trabalhos anteriores utilizaram raios produzidos por rea¸coes ressonantes de captura de pr´otons (p,x ). Entretanto, a cinem´atica da rea¸cao, em particular o efeito Doppler, altera a posi¸cao e forma dos picos observados. De modo a evitar estes efeitos indesej´aveis, este experimento utilizou uma fonte radioativa de raios de altas energias 66Ga (que recentemente tornou-se um dos padroes secund´arios de calibra¸cao). A fonte de 66Ga foi produzida por meio do bombardeamento de uma chapa de 1,0 mm de natZn de alta pureza (> 99,99%) utilizando um feixe de pr´otons de 15 MeV do ciclotron Cyclone 30 do Instituto de Pesquisas Energ´eticas e Nucleares IPEN, atrav´es das rea¸coes nucleares 66Zn(p,n) e 67Zn(p,2n). O espectro resultante foi analisado com o software IDFIX e foi obtida a curva de calibra¸cao de eficiencia de pico de um detetor HPGe de 162 cm3 de volume ativo e eficiencia de pico de 33% relativa a um cristal de 3×3 de Na(Tl) para o gama de 1332 keV do 60Co. Finalmente, foi realizada uma simula ¸cao do processo de transporte de radia¸cao por meio do software MNCP5 e os resultados obtidos encontram-se em acordo com os experimentais. / This work involves the study of the peak efficiency and response function of HPGe detectors for gamma rays in the energy range of 2 to 5 MeV, somewhat above the energy range of the available calibration sources for gamma spectroscopy. It is part of a high energy (up to 20MeV) -ray project to obtain intensity of rays from photo nuclear reactions produced with the bremstrahlung from the 38MeV electron beam of the Microtron accelerator. Former works carried out in the Laborat´orio do Acelerador Linear - LAL (IFUSP) used gamma rays produced by well-known (p,x ) resonant reactions. However reaction kinematics disturbs the position and form of the observed gamma peaks mainly due to the Doppler effect. In order to avoid these problems, a radioactive source with high energy gamma-rays, 66Ga (which recently became one of the secondary efficiency calibration standard), was used. The 66Ga source was produced by bombarding a 1.0 mm foil of pure natZn (> 99,99%) with the 15MeV and 0.1A proton beam from the Cyclone 30 cyclotron of the Instituto de Pesquisas Energ´eticas e Nucleares - IPEN with 66Zn(p,n) and 67Zn(p,2n) nuclear reactions. The resultant spectra were analyzed using the IDFIX program and the peak efficiency calibration curve was obtained for the HPGe detector with 162cm3 of active volume and a efficiency of 33% relative to a 3×3Na(Tl) crystal for 1332 keV 60Co ray. Finally, it was undertaken a Monte Carlo radiation transport analysis using a software such as MNCP5. The experiment was simulated and the results are in agreement with the experimental ones.
177

Comparação entre a nefrotoxicidade da crotoxina nativa e a irradiada com raios gama de Co-60 em camundongos / Comparative nephrotoxicity of native or Co-60gamma rays irradiated crotoxin in mice

Rocha, André Moreira 28 January 2016 (has links)
Os venenos das serpentes são compostos protéicos complexos com extensas atividades biológicas. Estas moléculas abrangem até 95% do peso seco do veneno, e compreendem enzimas, toxinas não enzimáticas e proteínas atóxicas. Dentre as complicações fisiológicas, a Insuficiência Renal Aguda - IRA é bem comum nos acidentes crotálicos, onde as concentrações renais do veneno se apresentam até 50% maiores do que na concentração plasmática. A fração tóxica responsável por essa complicação é a crotoxina. O veneno das serpentes, quando irradiado com raios gama de 60Co, tem a sua toxicidade diminuída, entretanto, são mantidas as suas propriedades imunológicas. Nossa hipótese é que a utilização de veneno irradiado em substituição ao nativo pode reduzir a taxa de lesões renais em animais de grande porte durante a produção de soros antiofídicos, propiciando melhor qualidade de vida e bem estar desses animais. No presente estudo realizou-se o isolamento da crotoxina por técnicas cromatográficas, a partir do veneno da serpente Crotalus durissus terrificus. Parte da toxina isolada foi reservada e denominada crotoxina nativa (CTXN) enquanto que outra parte foi irradiada com 2 kGy de raios gama oriundos de uma fonte de 60Co e denominada crotoxina irradiada (CTXI). Diferentes grupos de camundongos Balb/c receberam a toxina nativa ou irradiada e tiveram seus rins removidos em diferentes tempos pós-injeção da crotoxina. Realizou-se a nefrectomia dos animais e foi feito o preparo dos cortes histológicos em Hematoxilina-Eosina (HE) e cortes de imunohistoquímica com anticorpo policlonal de coelho anticrotoxina. As alterações histopatológicas encontradas nas amostras foram glomerulonefrite (GN), congestão capilar (CC) e necrose tubular aguda (NTA). Verificou-se que a GN teve maior ocorrência no grupo CTXN que no grupo CTXI. A NTA foi dominante no grupo CTXN em relação ao grupo CTXI. A CC foi predominante no grupo CTXI que no grupo CTXN. Entretanto esta diferença não é estatisticamente significante segundo o teste t Student de amostras independentes. O tratamento imunohistoquímico revelou que a concentração de antígeno marcado com o anticorpo é decrescente segundo os intervalos de tempo de eutanásia dos animais do grupo inoculado com CTXI, pois a crotoxina quando irradiada tem a sua excreção renal facilitada. Conclui-se que as alterações histopatológicas GN e a NTA foram significativamente menos frequentes em rins de animais inoculados com CTXI. Diferentemente da crotoxina nativa, a crotoxina irradiada é detectada pelo anticorpo anticrotoxina apenas nos tempos intermediários pós-inoculação e em baixa concentração, indicando que a radiação gama promoveu mudanças na forma de ligação da toxina ao tecido renal, facilitando sua eliminação e diminuindo, portanto, as chances de lesão. Esses resultados reforçam as evidências de que o uso de veneno irradiado no processo de imunização garante uma melhor qualidade de vida e bem estar aos animais soroprodutores. / Snake venoms are complex mixtures of proteins and peptides with a wide spectrum of physiological targets such as the blood coagulation and cardiovascular systems and the motor end plate among others. Acute renal failure is a common complication in accidents with the South American rattlesnake. The toxin involved in this pathology is crotoxin, a major component of the venom in terms of concentration and toxicity. Snake venoms, when irradiated with 60Co gamma rays present a significant decrease in toxicity while the immunogenic properties of its components are preserved. The use of irradiated rattlesnake venom is an attractive alternative for antisera production since it might reduce the appearance of renal lesions improving the welfare and lifespan of animals employed for antivenom production. In the present work, we have isolated crotoxin from crude venom of C. d. terrificus and irradiates part of it with 2 kGy of gamma rays from 60Co and compared the effects of native (CTXN) and irradiated (CTXI) crotoxin on the mice renal function. We conducted nephrectomy of animals and preparation of histological sections with hematoxylin-eosin (HE) and immunohistochemistry with polyclonal rabbit anticrotoxin for analysis in optical microscopy. Histopatological changes found in the samples were glomerulonephritis (GN), capillary congestion (CC) acute kidney tubular necrosis (NTA). Immunohistochemistry indicates that the concentration of bound antibody labelled antigen decreases in a time dependent manner. The GN ante NTA were significantly less frequent in kidneys of animals inoculated with irradiated toxin. The capillary congestion was evidenced in all animals treated with irradiated or native crotoxin. Concluding, ionizing radiation appears to mitigate the nephrotoxic effects of crotoxin and may represent an alternative for antivenin production, improving welfare for seroproductor animal.
178

"Medidas das secções de choque de fotonêutrons do 9Be, 13C e 17O com radiação Gama de captura de Nêutrons térmicos" / PHOTONEUTRON CROSS SECTIONS MEASUREMENTS IN 9Be, 13C e 17O WITH THERMAL NEUTRON CAPTURE GAMMA-RAYS

Semmler, Renato 19 May 2006 (has links)
Medidas das secções de choque de fotonêutrons do 9Be, 13C e 17O foram obtidas no intervalo de energia entre 1,6 e 10,8 MeV, utilizando radiação gama de alta resolução em energia (3 a 21 eV) produzida na captura de nêutrons térmicos por 21 materiais alvo, quando posicionados no interior de um canal tangencial, junto ao núcleo do reator de pesquisa IEAR1 (5 MW) do IPEN/CNEN-SP. As amostras foram irradiadas no interior de um sistema detector de nêutrons “Long Counter", de geometria 4π, a 520,5 cm de distância do alvo de captura. O fluxo de raios gama foi determinado por meio da análise do espectro gama obtido fazendo uso de um detector de estado sólido do tipo Ge(Li) (EG&G ORTEC, 25 cm3, 5%), previamente calibrado com raios gama de captura produzidos por uma amostra padrão de nitrogênio (Melamina). A secção de choque de fotonêutron foi medida para o espectro de raios gama de captura de cada alvo (secção de choque composta). Uma metodologia de inversão de matrizes para a resolução de problemas inverso discretos foi utilizada para a deconvolução do conjunto de valores experimentais da secção de choque composta, com a finalidade de obter a secção de choque em valores específicos de energia de excitação (energia das linhas gama principais dos alvos de captura). As secções de choque obtidas, nas energias das linhas gama principais de todos os alvos, foram comparadas com as medidas realizadas por outros autores utilizando diferentes fontes de radiação gama. Uma boa concordância foi observada entre os resultados experimentais deste trabalho com as relatados na literatura. / Photoneutron cross sections measurements of 9Be, 13C e 17O have been obtained in the energy interval between 1,6 and 10,8 MeV, using neutron capture gamma-rays with high resolution in energy (3 a 21 eV), produced by 21 target materials, placed inside a tangential beam port, near the core of the IPEN/CNEN-SP IEA-R1 (5 MW) research reactor. The samples have been irradiated inside a 4π geometry neutron detector system “Long Counter", 520,5 cm away from the capture target. The capture gamma-ray flux was determined by means of the analysis of the gamma spectrum obtained by using a Ge(Li) solid-state detector(EG&G ORTEC, 25 cm3, 5%), previously calibrated with capture gamma-rays from a standard target of Nitrogen (Melamine). The neutron photoproduction cross section has been measured for each target capture gamma-ray spectrum (compound cross section). A inversion matrix methodology to solve inversion problems for unfolding the set of experimental compound cross sections, was used in order to obtain the cross sections at specific excitation energy values (principal gamma line energies of the capture targets). The cross sections obtained at the energy values of the principal gamma lines were compared with experimental data reported by other authors, with have employed different gamma-ray sources. A good agreement was observed among the experimental data in this work with reported in the literature.
179

Characterization of drug and radiation sensitivity mechanisms in human hepatocellular carcinoma Hep G2 cells after fractionated gamma-irradiation. / CUHK electronic theses & dissertations collection

January 2004 (has links)
Tang Wan-yee. / "July 2004." / Thesis (Ph.D.)--Chinese University of Hong Kong, 2004. / Includes bibliographical references (p. 192-212). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Mode of access: World Wide Web.
180

Comparação entre a nefrotoxicidade da crotoxina nativa e a irradiada com raios gama de Co-60 em camundongos / Comparative nephrotoxicity of native or Co-60gamma rays irradiated crotoxin in mice

André Moreira Rocha 28 January 2016 (has links)
Os venenos das serpentes são compostos protéicos complexos com extensas atividades biológicas. Estas moléculas abrangem até 95% do peso seco do veneno, e compreendem enzimas, toxinas não enzimáticas e proteínas atóxicas. Dentre as complicações fisiológicas, a Insuficiência Renal Aguda - IRA é bem comum nos acidentes crotálicos, onde as concentrações renais do veneno se apresentam até 50% maiores do que na concentração plasmática. A fração tóxica responsável por essa complicação é a crotoxina. O veneno das serpentes, quando irradiado com raios gama de 60Co, tem a sua toxicidade diminuída, entretanto, são mantidas as suas propriedades imunológicas. Nossa hipótese é que a utilização de veneno irradiado em substituição ao nativo pode reduzir a taxa de lesões renais em animais de grande porte durante a produção de soros antiofídicos, propiciando melhor qualidade de vida e bem estar desses animais. No presente estudo realizou-se o isolamento da crotoxina por técnicas cromatográficas, a partir do veneno da serpente Crotalus durissus terrificus. Parte da toxina isolada foi reservada e denominada crotoxina nativa (CTXN) enquanto que outra parte foi irradiada com 2 kGy de raios gama oriundos de uma fonte de 60Co e denominada crotoxina irradiada (CTXI). Diferentes grupos de camundongos Balb/c receberam a toxina nativa ou irradiada e tiveram seus rins removidos em diferentes tempos pós-injeção da crotoxina. Realizou-se a nefrectomia dos animais e foi feito o preparo dos cortes histológicos em Hematoxilina-Eosina (HE) e cortes de imunohistoquímica com anticorpo policlonal de coelho anticrotoxina. As alterações histopatológicas encontradas nas amostras foram glomerulonefrite (GN), congestão capilar (CC) e necrose tubular aguda (NTA). Verificou-se que a GN teve maior ocorrência no grupo CTXN que no grupo CTXI. A NTA foi dominante no grupo CTXN em relação ao grupo CTXI. A CC foi predominante no grupo CTXI que no grupo CTXN. Entretanto esta diferença não é estatisticamente significante segundo o teste t Student de amostras independentes. O tratamento imunohistoquímico revelou que a concentração de antígeno marcado com o anticorpo é decrescente segundo os intervalos de tempo de eutanásia dos animais do grupo inoculado com CTXI, pois a crotoxina quando irradiada tem a sua excreção renal facilitada. Conclui-se que as alterações histopatológicas GN e a NTA foram significativamente menos frequentes em rins de animais inoculados com CTXI. Diferentemente da crotoxina nativa, a crotoxina irradiada é detectada pelo anticorpo anticrotoxina apenas nos tempos intermediários pós-inoculação e em baixa concentração, indicando que a radiação gama promoveu mudanças na forma de ligação da toxina ao tecido renal, facilitando sua eliminação e diminuindo, portanto, as chances de lesão. Esses resultados reforçam as evidências de que o uso de veneno irradiado no processo de imunização garante uma melhor qualidade de vida e bem estar aos animais soroprodutores. / Snake venoms are complex mixtures of proteins and peptides with a wide spectrum of physiological targets such as the blood coagulation and cardiovascular systems and the motor end plate among others. Acute renal failure is a common complication in accidents with the South American rattlesnake. The toxin involved in this pathology is crotoxin, a major component of the venom in terms of concentration and toxicity. Snake venoms, when irradiated with 60Co gamma rays present a significant decrease in toxicity while the immunogenic properties of its components are preserved. The use of irradiated rattlesnake venom is an attractive alternative for antisera production since it might reduce the appearance of renal lesions improving the welfare and lifespan of animals employed for antivenom production. In the present work, we have isolated crotoxin from crude venom of C. d. terrificus and irradiates part of it with 2 kGy of gamma rays from 60Co and compared the effects of native (CTXN) and irradiated (CTXI) crotoxin on the mice renal function. We conducted nephrectomy of animals and preparation of histological sections with hematoxylin-eosin (HE) and immunohistochemistry with polyclonal rabbit anticrotoxin for analysis in optical microscopy. Histopatological changes found in the samples were glomerulonephritis (GN), capillary congestion (CC) acute kidney tubular necrosis (NTA). Immunohistochemistry indicates that the concentration of bound antibody labelled antigen decreases in a time dependent manner. The GN ante NTA were significantly less frequent in kidneys of animals inoculated with irradiated toxin. The capillary congestion was evidenced in all animals treated with irradiated or native crotoxin. Concluding, ionizing radiation appears to mitigate the nephrotoxic effects of crotoxin and may represent an alternative for antivenin production, improving welfare for seroproductor animal.

Page generated in 0.0474 seconds