• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 46
  • 1
  • Tagged with
  • 47
  • 47
  • 35
  • 33
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Gasto energético de pacientes com síndrome do intestino curto: avaliação pelo método da água duplamente marcada / Energy expenditure in patients with short bowel syndrome: assessment using the doubly labeled water method

Fassini, Priscila Giacomo 13 September 2016 (has links)
Introdução: A síndrome do intestino curto (SIC) representa um estado clínico de má absorção grave, e a gestão dietética de pacientes com SIC é extremamente desafiadora. Uma vez que o grau de desnutrição é frequentemente considerável, a intervenção dietética bem sucedida depende da estimativa mais exata possível das necessidades energéticas para prever as metas da terapia nutricional. Objetivo: Quantificar o gasto energético total (GET) em pacientes com SIC pelo método da água duplamente marcada (ADM). Materiais e Métodos: Neste estudo observacional, o GET foi mensurado pelo método da água duplamente marcada em 22 voluntários, 11 com SIC e 11 controles pareados por sexo, idade e IMC (grupo Controle). O GET foi estimado pela equação de Escott-Stump e a partir de acelerômetro, e foi comparado com o GET determinado pela ADM. O gasto energético em repouso (GER) foi mensurado por calorimetria indireta (CI) e comparado com o GER estimado pela equação de Harris e Benedict. O acelerômetro também foi utilizado para estabelecer o nível de atividade física. Resultados: Os participantes tinham idade (média ± DP) de 53 ± 8 anos. O GET medido por ADM foi significativamente menor no grupo SIC comparado ao grupo Controle (p < 0,01); no entanto, o GET estimado não diferiu significativamente entre os grupos. O GET medido foi significativamente maior do que o GET estimado por fórmula no grupo SIC, (respectivamente 1875 ± 276 e 1517 ± 175 kcal/dia, p < 0,01), assim como para o grupo Controle (2393 ± 445 e 1532 ± 178 kcal/dia, p < 0,01). No entanto, o GET medido foi significativamente menor do que o GET predito a partir do acelerômetro no grupo SIC (2075 ± 298 kcal/dia, p = 0,02), e não diferiu significativamente no grupo Controle (2207 ± 355 kcal/dia, p = 0,21). Não foram verificadas diferenças significantes entre o GER medido e predito para ambos, e entre os grupos. Conclusão: O GET medido em pacientes com SIC foi significativamente maior do que o GET estimado por fórmula, e foi menor quando comparado com os valores dos sujeitos controles. No entanto, o GET estimado a partir do acelerômetro, superestima o GET medido por ADM. As fórmulas atualmente utilizadas na prática clínica parecem subestimar as necessidades de energia de pacientes com SIC. Desta forma, adaptações da estimativa atual, aumentando as prescrições de ingestão energética nestes pacientes parecem ser adequadas para apoiar as necessidades diárias de energia e evitar a subnutrição. / Background: Short bowel syndrome (SBS) is a serious malabsorption disorder, and dietetic management of SBS patients is extremely challenging. Once the degree of undernutrition has been assessed, successful dietary intervention depends on the most accurate estimation and provision of energy needs to provide nutritional therapy goals. Objective: To quantify total energy expenditure (TEE) in SBS patients using the doubly labeled water (DLW) method. Design: In this observational study, TEE was measured by the DLW method in 22 participants, 11 with SBS and 11 gender-age-and BMI-matched controls (Control group). Predicted energy requirements were determined using the Escott-Stump equation and by using and accelerometer, and they were compared with TEE determined with DLW. Resting energy expenditure (REE) was measured using indirect calorimetry and compared with predict REE using the Harris and Benedict equation. The accelerometer was also used to determine physical activity level. Results: Participants were aged (mean ± SD) 53 ± 8 years. Measured TEE was significantly lower in the SBS group compared to the Control group (p < 0.01); however, predicted TEE did not differ significantly between the groups. Measured TEE was significantly higher than predicted TEE for the SBS group, (1875 ± 276 and 1517 ± 175 kcal/d, p < 0.01) and also for the Control group (2393 ± 445 and 1532 ± 178 kcal/d, p < 0.01) when determined by formula. However, measured TEE was significantly lower than predicted TEE (2075 ± 298 kcal/d, p = 0.02) for the SBS group, and did not differ for the Control group (2207 ± 355 kcal/d, p = 0.21) when determined by accelerometer. No significant differences were seen between measured and predicted REE both within and between groups. Conclusion: Measured TEE in SBS patients was significantly higher than predicted using standard equations, but also lower than values for age, BMI and gender-matched non-SBS controls. However, predicted TEE using accelerometer overestimated the measured TEE. Currently-used formulas in clinical practice appear to underestimate energy requirements of SBS patients. Therefore, adjustments to the current estimation, increasing the energy intake requirements in these patients appear to be adequate to support the daily energy requirements and avoid undernutrition.
22

Gasto energético de pacientes com síndrome do intestino curto: avaliação pelo método da água duplamente marcada / Energy expenditure in patients with short bowel syndrome: assessment using the doubly labeled water method

Priscila Giacomo Fassini 13 September 2016 (has links)
Introdução: A síndrome do intestino curto (SIC) representa um estado clínico de má absorção grave, e a gestão dietética de pacientes com SIC é extremamente desafiadora. Uma vez que o grau de desnutrição é frequentemente considerável, a intervenção dietética bem sucedida depende da estimativa mais exata possível das necessidades energéticas para prever as metas da terapia nutricional. Objetivo: Quantificar o gasto energético total (GET) em pacientes com SIC pelo método da água duplamente marcada (ADM). Materiais e Métodos: Neste estudo observacional, o GET foi mensurado pelo método da água duplamente marcada em 22 voluntários, 11 com SIC e 11 controles pareados por sexo, idade e IMC (grupo Controle). O GET foi estimado pela equação de Escott-Stump e a partir de acelerômetro, e foi comparado com o GET determinado pela ADM. O gasto energético em repouso (GER) foi mensurado por calorimetria indireta (CI) e comparado com o GER estimado pela equação de Harris e Benedict. O acelerômetro também foi utilizado para estabelecer o nível de atividade física. Resultados: Os participantes tinham idade (média ± DP) de 53 ± 8 anos. O GET medido por ADM foi significativamente menor no grupo SIC comparado ao grupo Controle (p < 0,01); no entanto, o GET estimado não diferiu significativamente entre os grupos. O GET medido foi significativamente maior do que o GET estimado por fórmula no grupo SIC, (respectivamente 1875 ± 276 e 1517 ± 175 kcal/dia, p < 0,01), assim como para o grupo Controle (2393 ± 445 e 1532 ± 178 kcal/dia, p < 0,01). No entanto, o GET medido foi significativamente menor do que o GET predito a partir do acelerômetro no grupo SIC (2075 ± 298 kcal/dia, p = 0,02), e não diferiu significativamente no grupo Controle (2207 ± 355 kcal/dia, p = 0,21). Não foram verificadas diferenças significantes entre o GER medido e predito para ambos, e entre os grupos. Conclusão: O GET medido em pacientes com SIC foi significativamente maior do que o GET estimado por fórmula, e foi menor quando comparado com os valores dos sujeitos controles. No entanto, o GET estimado a partir do acelerômetro, superestima o GET medido por ADM. As fórmulas atualmente utilizadas na prática clínica parecem subestimar as necessidades de energia de pacientes com SIC. Desta forma, adaptações da estimativa atual, aumentando as prescrições de ingestão energética nestes pacientes parecem ser adequadas para apoiar as necessidades diárias de energia e evitar a subnutrição. / Background: Short bowel syndrome (SBS) is a serious malabsorption disorder, and dietetic management of SBS patients is extremely challenging. Once the degree of undernutrition has been assessed, successful dietary intervention depends on the most accurate estimation and provision of energy needs to provide nutritional therapy goals. Objective: To quantify total energy expenditure (TEE) in SBS patients using the doubly labeled water (DLW) method. Design: In this observational study, TEE was measured by the DLW method in 22 participants, 11 with SBS and 11 gender-age-and BMI-matched controls (Control group). Predicted energy requirements were determined using the Escott-Stump equation and by using and accelerometer, and they were compared with TEE determined with DLW. Resting energy expenditure (REE) was measured using indirect calorimetry and compared with predict REE using the Harris and Benedict equation. The accelerometer was also used to determine physical activity level. Results: Participants were aged (mean ± SD) 53 ± 8 years. Measured TEE was significantly lower in the SBS group compared to the Control group (p < 0.01); however, predicted TEE did not differ significantly between the groups. Measured TEE was significantly higher than predicted TEE for the SBS group, (1875 ± 276 and 1517 ± 175 kcal/d, p < 0.01) and also for the Control group (2393 ± 445 and 1532 ± 178 kcal/d, p < 0.01) when determined by formula. However, measured TEE was significantly lower than predicted TEE (2075 ± 298 kcal/d, p = 0.02) for the SBS group, and did not differ for the Control group (2207 ± 355 kcal/d, p = 0.21) when determined by accelerometer. No significant differences were seen between measured and predicted REE both within and between groups. Conclusion: Measured TEE in SBS patients was significantly higher than predicted using standard equations, but also lower than values for age, BMI and gender-matched non-SBS controls. However, predicted TEE using accelerometer overestimated the measured TEE. Currently-used formulas in clinical practice appear to underestimate energy requirements of SBS patients. Therefore, adjustments to the current estimation, increasing the energy intake requirements in these patients appear to be adequate to support the daily energy requirements and avoid undernutrition.
23

Questionário de frequência alimentar para idosos saudáveis: Validação da ingestão de energia pelo método da água duplamente marcada / Food frequency questionnaire to healthy elderly: Validation of energy intake for using the doubly labeled water

Marchesi, Juliana Cristina Lemos de Souza 15 March 2018 (has links)
Espera-se que entre 2010 e 2050, a população mundial total terá um aumento de 2 bilhões de habitantes, ao passo que a população idosa chegará ao número de 1,3 bilhões de habitantes. Dentre os diversos fatores envolvidos com expectativa de vida longa, está bem estabelecido que o hábito alimentar desempenha um papel central para a saúde, o que torna importante o conhecimento do padrão alimentar nesta faixa etária. Para a avaliação da ingestão alimentar média a longo prazo em grande número de indivíduos, os Questionários de Frequência de Alimentos (QFAs) são instrumentos particularmente importantes. Objetivo: validar um questionário de frequência alimentar para idosos saudáveis. Casuística e Métodos: Participaram da pesquisa 43 idosos independentes, com a capacidade cognitiva e funcional preservadas, de ambos os gêneros, com idades > 60 anos. Foi avaliado o consumo alimentar dos indivíduos por meio de 3 recordatórios alimentares de 24 horas e um questionário de frequência alimentar, com o auxílio de um livro de fotografias para visualização do tamanho das porções dos alimentos. Como método padrão-ouro, foi utilizada a água duplamente marcada (DLW) para aferição do gasto energético total diário. Para a análise estatística, foi realizada análise descritiva dos dados, calculado o coeficiente de correlação de Spearman, construídos gráficos de dispersão e de Bland-Altman, e também o Coeficiente de Correlação Intraclasse (ICC). Foi adotado o nível de significância de 5%. Resultados: foi observada excelente concordância entre o QFA e DLW para estimativa do consumo de energia em mulheres idosas, assim boa correlação entre o R24h e DLW para estimativa do consumo de energia em homens idosos. Não foram encontradas correlações significativas entre o QFA e DLW para estimativa do consumo de energia em ambos os sexos. Conclusão: Considerando que o objetivo desta pesquisa foi validar o QFA para os dois gêneros (homem e mulher), o mesmo não foi alcançado. / Introduction: It is expected that between 2010 and 2050, the total world population will increase by 2 billion inhabitants, while the elderly population will reach 1.3 billion. Among the many factors involved in long life expectancy, it is well established that eating habits play a central role in health, which makes it important to know the food pattern in this age group. For the evaluation of the long-term average food intake in a large number of individuals, Food Frequency Questionnaires (FFQs) are particularly important instruments. Objective: to validate a food frequency questionnaire for healthy elderly. METHODS: Participants were 43 independent, with cognitive and functional capacity, of both genders, aged> 60 years. The individuals\' food consumption was evaluated through three 24-hour recalls and a food frequency questionnaire, with the aid of a photo book to visualize the size of the food portions. As a gold standard method, double-labeled water (DLW) was used to measure total daily energy expenditure. For the statistical analysis, a descriptive analysis of the data was performed, the Spearman correlation coefficient was calculated, the dispersion and Bland-Altman graphs were constructed, as well as the Intraclass Correlation Coefficient (ICC). The significance level of 5% was adopted. Results: excellent concordance was observed between the QFA and DLW for estimation of energy consumption in elderly women, thus a good correlation between R24h and DLW for estimation of energy consumption in elderly men. No significant correlations were found between the QFA and DLW to estimate the energy consumption in both sexes. Conclusion: Considering that the objective of this research was to validate the FFQ for both genders (man and woman), the same was not achieved.
24

Influência da sobrecarga de líquidos sobre estado nutricional, gasto energético de repouso e biomarcador de risco cardiovascular em pacientes tratados por diálise peritoneal / Influence of fluid overload on nutritional status, resting energy expenditure and biomarker of cardiovascular risk in patients treated by peritoneal dialysis

Santos, Nathália Zanon dos 21 November 2016 (has links)
A sobrecarga hídrica (SH) é um achado comum em pacientes em diálise peritoneal (DP) e a inadequação do estado nutricional aumenta a morbimortalidade nesta população. A bioimpedância elétrica é um método rápido e não-invasivo para estimar os compartimentos corporais, incluindo a distribuição dos fluídos corporais nos espaços intra e extracelulares. O principal objetivo foi avaliar se a SH interfere em estado nutricional, composição corporal, gasto energético de repouso e um biomarcador de risco cardiovascular, em pacientes com Doença Renal Crônica tratados por DP. Caracterizou-se como um estudo observacional transversal, realizado no Hospital das Clínicas da FMRP-USP. Foram avaliados dados de composição corporal e estado hídrico por Bioimpedância Elétrica de Frequência Simples (BIA) e Bioimpedância Elétrica Multifrequência de Espectroscopia (BIS), a concentração sérica do peptídeo natriurético atrial (Nt pro - BNP) como biomarcador de risco cardiovascular, dados antropométricos, de consumo alimentar, gasto energético de repouso (GER), exames bioquímicos e dados clínicos de rotina dos pacientes. Trinta pacientes foram incluídos e classificados em normohidratados (NH) ou hiperhidratados (HH), pelo valor de sobrecarga hídrica de 1,1 L. Para análise estatística, o nível de significância foi pré-fixado em ?= 0,05. Os pacientes HH, em comparação aos NH, apresentaram além de maior sobrecarga hídrica (3,54 L ± 1,7 X 0,14 ± 0,6), maiores valores em água corporal total (ACT - 34,98 L ± 4,74 X 30,43 L ± 5,45), água extracelular (AEC - 17,91 L ± 2,87 X 13,84 L ± 2,30) e menores valores de ângulo de fase (4,02° ± 0,81 X 5,51° ± 0,77) na avalição por BIS; o Nt Pró - BNP mostrou-se maior nos HH (7686 pg/ml ± 8872 X 1334 pg/ml ± 1034). Não houve diferença significativa entre os grupos para dados antropométricos, nos demais exames bioquímicos, em aferições da força de preensão palmar, nas pontuações do MIS (Malnutrition Inflammation Score), nos dados de ingestão alimentar, e nem no GER. O grupo com sobrecarga hídrica mostrou, de fato, uma maior concentração de água em compartimento extracelular, possivelmente gerando aumento em Nt pro - BNP e menor ângulo de fase. Quando avaliado o grupo como um todo, os métodos (BIA e BIS) mediram os resultados igualmente somente no que se refere à resistência (p = 0,71). Sendo a ACT, água intracelular (AIC), AEC, massa livre de gordura (MLG), massa celular corporal (MCC) e ângulo de fase maiores na medições da BIA e somente massa gorda maior nas medições da BIS; correlações mostraram que os dados de massa livre de gordura e massa celular corporal foram os que mais se distanciaram, com coeficientes mais fracos, enquanto que as demais variáveis apresentaram forte correlação. Para o diagnóstico nutricional em vigência de sobrecarga líquida, deve-se considerar um conjunto de variáveis interpretadas de maneira complementar, possibilitando um diagnóstico nutricional mais detalhado. O uso rotineiro da BIS pode ajudar a refinar a avaliação do estado de hidratação e composição corporal destes pacientes em DP. / The fluid overload (FO) is a common finding in patients on peritoneal dialysis (PD) and the inadequacy of the nutritional status increases the morbidity and mortality in this population. The bioelectrical impedance is a quick and non-invasive method to estimate body compartments, including the distribution of body fluids in intra- and extracellular spaces. The main objective was to assess whether the FO affects body cell mass, nutritional status, resting energy expenditure and a biomarker of cardiovascular risk in patients with chronic kidney disease treated by PD. It is characterized as a cross-sectional observational study conducted at the Hospital of FMRP-USP. We evaluated data of body composition and water status by Simple Frequency Electric Bioimpedance (BIA) and Electric Multifrequency Spectroscopy Bioimpedance (BIS), the serum concentration of atrial natriuretic peptide (NT pro - BNP) as a biomarker of cardiovascular risk, anthropometric data, food intake, resting energy expenditure (REE), biochemical and clinical data from routine patient. Thirty patients were included and classified into normal hydration (NH) or hyper hydrated (HH) by fluid overload value of 1.1 L. For statistical analysis, the level of significance was pre-set at ? = 0.05. HH patients, compared to NH, presented in addition to increased fluid overload (3.54 L ± 1.7 X 0.14 ± 0.6), higher values in total body water (TBW - 34.98 L ± 4.74 ± 5.45 x 30.43 L), extracellular water (ECW - L 17.91 ± 2.87 X 13.84 ± 2.30 L) and smaller phase angle values (± 4.02 ° 0.81 X 5.51 ± 0.77 °) in a BIS appraisal; the Nt Pro - BNP was higher in HH (7686 pg / ml ± 8872 X 1334 pg / ml ± 1034). There was no significant difference between groups for anthropometric data, in other biochemical tests on measurements of grip strength, in scores of MIS (Malnutrition Inflammation Score), the food intake data, and not the REE. The group with fluid overload shows, in fact, a higher concentration of water in the extracellular compartment, possibly generating an increase in NT pro - BNP and lower phase angle. When evaluated the group as a whole, the methods (BIA and BIS) measure only the results also as regards the resistance (p = 0.71). And TBW, intracellular water, ECW, fat-free mass, body cell mass and larger phase angle measurements in the BIA and only greater fat mass in measurements of BIS; correlations show that free mass data of fat and body cell mass are the ones who are more distanced, with weaker coefficients, while the other variables are strongly correlated. For the nutritional diagnosis of fluid overload force, should be considered a set of variables interpreted in a complementary manner, enabling a more detailed nutritional diagnosis. The routine use of BIS can help refine the assessment of hydration status and body composition of these patients on PD.
25

Comparação do Gasto energético de repouso obtido pela calorimetria indireta com as equações de predição em pacientes idosos em tratamento crônico de hemodiálise / Comparison of resting energy expenditure obtained by indirect calorimetry with predictive equations for elderly patients on chronic hemodialysis treatment

Juliana Cordeiro Dias Rodrigues 12 June 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Assim como na população geral, as necessidades energéticas diárias dos pacientes em tratamento crônico de hemodiálise (HD) podem ser calculadas multiplicando-se o gasto energético de repouso (GER) pelo nível de atividade física. Até o momento, não há estudos que avaliaram se as equações de predição são precisas para se estimar o GER de idosos em HD. O objetivo do presente estudo foi avaliar a concordância entre o GER obtido pela calorimetria indireta e as equações de predição de Harris&Benedict, Schofield e a proposta pelo documento da Organização Mundial de Saúde de 1985 (FAO 1985) nos pacientes idosos em HD. Tratou-se de um estudo transversal, onde foi avaliado o GER de 57 pacientes idosos não institucionalizados (> 60anos) em tratamento crônico de HD mensurado pela calorimetria indireta e comparado com as equações de predição de Harris&Benedict, Schofield e FAO 1985.A concordância entre o GER medido e as equações foi realizada pelo coeficiente de correlação intraclasse e pela análise de Bland-Altman. Neste estudo pode-se observar que o GER estimado pelas 3 equações foi significantemente maior do que o obtido pela calorimetria indireta. Um grau de reprodutibilidade moderado foi observado entre a calorimetria indireta e as equações. A superestimação foi o principal erro observado, sendo presente na metade dos pacientes. A subestimação foi vista em aproximadamente em 10 % dos pacientes. Com base nesses achados podemos concluir que as 3 equações tiveram uma performance similar ao estimar o GER. E estas podem ser utilizadas para calcular o GER de idosos em HD, na medida em que os nutricionistas reconheçam seus possíveis erros, principalmente quando as equações de predição subestimam o GER medido. / Objectives: The daily energy requirements of hemodialysis (HD) patients can be calculated by multiplying the resting energy expenditure (REE) by the physical activity level. Up to now, there are no studies assessing whether prediction equations are accurate to assess the REE in elderly HD. We aimed to evaluate the agreement between the REE obtained by indirect calorimetry and the prediction equations of Harris&Benedict, Schofield and World Health Organization 1985 (WHO 1985) in elderly patients on hemodialysis (HD). Design, setting and participants: This is a cross-sectional study. The REE of 57 elderly non-institutionalized patients (> 60 years) on HD was measured by indirect calorimetry and compared with the prediction equations of Harris&Benedict, Schofield and WHO 1985. The agreement between the REE and the equations were assessed by the intraclass correlation coefficient and by the Bland-Altman plot analysis. Results: The REE estimated by the 3 equations were significantly higher than that obtained by the indirect calorimetry. A moderate degree of reproducibility was observed between the indirect calorimetry and the equations. Overestimation was the main error observed, being present in half of the patients. Underestimation was seen in approximately 10% of the patients. Conclusion: These 3 equations performed similarly when estimating the REE. They can be used to calculate the REE in elderly HD, but clinicians should be aware of possible errors, mainly when prediction equations underestimate the measured REE.
26

Influência da sobrecarga de líquidos sobre estado nutricional, gasto energético de repouso e biomarcador de risco cardiovascular em pacientes tratados por diálise peritoneal / Influence of fluid overload on nutritional status, resting energy expenditure and biomarker of cardiovascular risk in patients treated by peritoneal dialysis

Nathália Zanon dos Santos 21 November 2016 (has links)
A sobrecarga hídrica (SH) é um achado comum em pacientes em diálise peritoneal (DP) e a inadequação do estado nutricional aumenta a morbimortalidade nesta população. A bioimpedância elétrica é um método rápido e não-invasivo para estimar os compartimentos corporais, incluindo a distribuição dos fluídos corporais nos espaços intra e extracelulares. O principal objetivo foi avaliar se a SH interfere em estado nutricional, composição corporal, gasto energético de repouso e um biomarcador de risco cardiovascular, em pacientes com Doença Renal Crônica tratados por DP. Caracterizou-se como um estudo observacional transversal, realizado no Hospital das Clínicas da FMRP-USP. Foram avaliados dados de composição corporal e estado hídrico por Bioimpedância Elétrica de Frequência Simples (BIA) e Bioimpedância Elétrica Multifrequência de Espectroscopia (BIS), a concentração sérica do peptídeo natriurético atrial (Nt pro - BNP) como biomarcador de risco cardiovascular, dados antropométricos, de consumo alimentar, gasto energético de repouso (GER), exames bioquímicos e dados clínicos de rotina dos pacientes. Trinta pacientes foram incluídos e classificados em normohidratados (NH) ou hiperhidratados (HH), pelo valor de sobrecarga hídrica de 1,1 L. Para análise estatística, o nível de significância foi pré-fixado em ?= 0,05. Os pacientes HH, em comparação aos NH, apresentaram além de maior sobrecarga hídrica (3,54 L ± 1,7 X 0,14 ± 0,6), maiores valores em água corporal total (ACT - 34,98 L ± 4,74 X 30,43 L ± 5,45), água extracelular (AEC - 17,91 L ± 2,87 X 13,84 L ± 2,30) e menores valores de ângulo de fase (4,02° ± 0,81 X 5,51° ± 0,77) na avalição por BIS; o Nt Pró - BNP mostrou-se maior nos HH (7686 pg/ml ± 8872 X 1334 pg/ml ± 1034). Não houve diferença significativa entre os grupos para dados antropométricos, nos demais exames bioquímicos, em aferições da força de preensão palmar, nas pontuações do MIS (Malnutrition Inflammation Score), nos dados de ingestão alimentar, e nem no GER. O grupo com sobrecarga hídrica mostrou, de fato, uma maior concentração de água em compartimento extracelular, possivelmente gerando aumento em Nt pro - BNP e menor ângulo de fase. Quando avaliado o grupo como um todo, os métodos (BIA e BIS) mediram os resultados igualmente somente no que se refere à resistência (p = 0,71). Sendo a ACT, água intracelular (AIC), AEC, massa livre de gordura (MLG), massa celular corporal (MCC) e ângulo de fase maiores na medições da BIA e somente massa gorda maior nas medições da BIS; correlações mostraram que os dados de massa livre de gordura e massa celular corporal foram os que mais se distanciaram, com coeficientes mais fracos, enquanto que as demais variáveis apresentaram forte correlação. Para o diagnóstico nutricional em vigência de sobrecarga líquida, deve-se considerar um conjunto de variáveis interpretadas de maneira complementar, possibilitando um diagnóstico nutricional mais detalhado. O uso rotineiro da BIS pode ajudar a refinar a avaliação do estado de hidratação e composição corporal destes pacientes em DP. / The fluid overload (FO) is a common finding in patients on peritoneal dialysis (PD) and the inadequacy of the nutritional status increases the morbidity and mortality in this population. The bioelectrical impedance is a quick and non-invasive method to estimate body compartments, including the distribution of body fluids in intra- and extracellular spaces. The main objective was to assess whether the FO affects body cell mass, nutritional status, resting energy expenditure and a biomarker of cardiovascular risk in patients with chronic kidney disease treated by PD. It is characterized as a cross-sectional observational study conducted at the Hospital of FMRP-USP. We evaluated data of body composition and water status by Simple Frequency Electric Bioimpedance (BIA) and Electric Multifrequency Spectroscopy Bioimpedance (BIS), the serum concentration of atrial natriuretic peptide (NT pro - BNP) as a biomarker of cardiovascular risk, anthropometric data, food intake, resting energy expenditure (REE), biochemical and clinical data from routine patient. Thirty patients were included and classified into normal hydration (NH) or hyper hydrated (HH) by fluid overload value of 1.1 L. For statistical analysis, the level of significance was pre-set at ? = 0.05. HH patients, compared to NH, presented in addition to increased fluid overload (3.54 L ± 1.7 X 0.14 ± 0.6), higher values in total body water (TBW - 34.98 L ± 4.74 ± 5.45 x 30.43 L), extracellular water (ECW - L 17.91 ± 2.87 X 13.84 ± 2.30 L) and smaller phase angle values (± 4.02 ° 0.81 X 5.51 ± 0.77 °) in a BIS appraisal; the Nt Pro - BNP was higher in HH (7686 pg / ml ± 8872 X 1334 pg / ml ± 1034). There was no significant difference between groups for anthropometric data, in other biochemical tests on measurements of grip strength, in scores of MIS (Malnutrition Inflammation Score), the food intake data, and not the REE. The group with fluid overload shows, in fact, a higher concentration of water in the extracellular compartment, possibly generating an increase in NT pro - BNP and lower phase angle. When evaluated the group as a whole, the methods (BIA and BIS) measure only the results also as regards the resistance (p = 0.71). And TBW, intracellular water, ECW, fat-free mass, body cell mass and larger phase angle measurements in the BIA and only greater fat mass in measurements of BIS; correlations show that free mass data of fat and body cell mass are the ones who are more distanced, with weaker coefficients, while the other variables are strongly correlated. For the nutritional diagnosis of fluid overload force, should be considered a set of variables interpreted in a complementary manner, enabling a more detailed nutritional diagnosis. The routine use of BIS can help refine the assessment of hydration status and body composition of these patients on PD.
27

Análise do gasto energético e composição corporal de adolescentes obesos sedentários e de adolescentes obesos submetidos a treinamento concorrente

Bastos, Karolynne das Neves [UNESP] 25 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:49Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-25Bitstream added on 2014-06-13T18:08:39Z : No. of bitstreams: 1 bastos_kn_me_prud.pdf: 909275 bytes, checksum: 47774cd02b6c9356a1379ce3a33ac502 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: Analisar o gasto energético (GE) e a composição corporal de adolescentes obesos sedentários pré e pós teste de esforço máximo e analisar os resultados de adolescentes obesos submetidos a treinamento concorrente. Metodologia: A amostra foi composta por dois grupos: 1) grupo sedentário (GS), composto por 70 adolescentes (31 meninos e 39 meninas; idade 13,7±1,4 anos); 2) grupo treinado (GT), composto por 16 adolescentes (10 meninos e 6 meninas; idade 14,7±1,0 anos), participantes de um programa para redução de gordura corporal. O Índice de Massa Corporal (IMC) foi usado para classificação da obesidade, segundo Cole et al. (2000). A composição corporal foi analisada pela Absortiometria de Raios- X de Dupla Energia (Dual-energy x-ray absorptiometry - DEXA) para estimativa da massa livre de gordura (MLG) e da massa de gordura (MG). O GE foi calculado a partir da equação de Weir (1949) [(3.941xVO2)+(1.106xVCO2)*1440], utilizando os valores de volume de oxigênio consumido (VO2) e gás carbônico produzido (VCO2), mensurados a cada 20 segundos por Calorimetria Indireta (CI) durante 20 minutos, antes (repouso – REP), durante e após (recuperação – REC) esforço máximo realizado em esteira ergométrica, com o sistema MedGraphics VO2000 no GS e no momento pré intervenção do GT, e com o sistema Parvo Medics TrueOne® 2400 no momento pós intervenção do GT. O GT participou de uma intervenção de 40 semanas de treinamento concorrente (TC), com frequência semanal de três vezes e duração de 60 minutos por sessão (aproximadamente 50% do tempo de treino aeróbio e 50% de treino resistido (musculação)). A análise estatística foi realizada no software SPSS versão 17.0 e a significância estatística foi fixada em 5%... / Objective: To analyze the energy expenditure (EE) and body composition of obese sedentary before and after maximal exercise test and analyze the results of obese adolescents undergoing concurrent training. Methods: The sample comprised two groups: 1) sedentary group (SG), composed of 70 adolescents (31 boys and 39 girls, age 13.7 ± 1.4 years), 2) the trained group (TG), composed of 16 adolescents (10 boys and 6 girls, age 14.7 ± 1.0 years) participating in a program to reduce body fat. The Body Mass Index (BMI) was used for classification of obesity according to Cole et al. (2000). Body composition was analyzed by X-ray Absorptiometry Dual Energy (DEXA) to estimate fat-free mass (FFM) and fat mass (FM). EE was calculated from the Weir (1949) equation [(3.941xVO2) + (1.106xVCO2)*1440], using the values of volume of oxygen consumed (VO2) and volume of carbon dioxide produced (VCO2), measured every 20 seconds Indirect Calorimetry (IC) for 20 minutes before (rest - RES), during and after (recovery - REC) performed maximal treadmill, with the system MedGraphics VO2000 in SG and in the pre intervention TG, and the system Parvo Medics TrueOne ® 2400 after intervention in TG. The TG participated in an intervention of 40 weeks of concurrent training (CT) with three times weekly frequency and duration of 60 minutes per session (approximately 50% of the time of aerobic training and 50% of resistance training (weight training)). Statistical analysis was performed with SPSS version 17.0 and statistical significance was set at 5%... (Complete abstract click electronic access below)
28

Comparação do Gasto energético de repouso obtido pela calorimetria indireta com as equações de predição em pacientes idosos em tratamento crônico de hemodiálise / Comparison of resting energy expenditure obtained by indirect calorimetry with predictive equations for elderly patients on chronic hemodialysis treatment

Juliana Cordeiro Dias Rodrigues 12 June 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Assim como na população geral, as necessidades energéticas diárias dos pacientes em tratamento crônico de hemodiálise (HD) podem ser calculadas multiplicando-se o gasto energético de repouso (GER) pelo nível de atividade física. Até o momento, não há estudos que avaliaram se as equações de predição são precisas para se estimar o GER de idosos em HD. O objetivo do presente estudo foi avaliar a concordância entre o GER obtido pela calorimetria indireta e as equações de predição de Harris&Benedict, Schofield e a proposta pelo documento da Organização Mundial de Saúde de 1985 (FAO 1985) nos pacientes idosos em HD. Tratou-se de um estudo transversal, onde foi avaliado o GER de 57 pacientes idosos não institucionalizados (> 60anos) em tratamento crônico de HD mensurado pela calorimetria indireta e comparado com as equações de predição de Harris&Benedict, Schofield e FAO 1985.A concordância entre o GER medido e as equações foi realizada pelo coeficiente de correlação intraclasse e pela análise de Bland-Altman. Neste estudo pode-se observar que o GER estimado pelas 3 equações foi significantemente maior do que o obtido pela calorimetria indireta. Um grau de reprodutibilidade moderado foi observado entre a calorimetria indireta e as equações. A superestimação foi o principal erro observado, sendo presente na metade dos pacientes. A subestimação foi vista em aproximadamente em 10 % dos pacientes. Com base nesses achados podemos concluir que as 3 equações tiveram uma performance similar ao estimar o GER. E estas podem ser utilizadas para calcular o GER de idosos em HD, na medida em que os nutricionistas reconheçam seus possíveis erros, principalmente quando as equações de predição subestimam o GER medido. / Objectives: The daily energy requirements of hemodialysis (HD) patients can be calculated by multiplying the resting energy expenditure (REE) by the physical activity level. Up to now, there are no studies assessing whether prediction equations are accurate to assess the REE in elderly HD. We aimed to evaluate the agreement between the REE obtained by indirect calorimetry and the prediction equations of Harris&Benedict, Schofield and World Health Organization 1985 (WHO 1985) in elderly patients on hemodialysis (HD). Design, setting and participants: This is a cross-sectional study. The REE of 57 elderly non-institutionalized patients (> 60 years) on HD was measured by indirect calorimetry and compared with the prediction equations of Harris&Benedict, Schofield and WHO 1985. The agreement between the REE and the equations were assessed by the intraclass correlation coefficient and by the Bland-Altman plot analysis. Results: The REE estimated by the 3 equations were significantly higher than that obtained by the indirect calorimetry. A moderate degree of reproducibility was observed between the indirect calorimetry and the equations. Overestimation was the main error observed, being present in half of the patients. Underestimation was seen in approximately 10% of the patients. Conclusion: These 3 equations performed similarly when estimating the REE. They can be used to calculate the REE in elderly HD, but clinicians should be aware of possible errors, mainly when prediction equations underestimate the measured REE.
29

Questionário de frequência alimentar para idosos saudáveis: Validação da ingestão de energia pelo método da água duplamente marcada / Food frequency questionnaire to healthy elderly: Validation of energy intake for using the doubly labeled water

Juliana Cristina Lemos de Souza Marchesi 15 March 2018 (has links)
Espera-se que entre 2010 e 2050, a população mundial total terá um aumento de 2 bilhões de habitantes, ao passo que a população idosa chegará ao número de 1,3 bilhões de habitantes. Dentre os diversos fatores envolvidos com expectativa de vida longa, está bem estabelecido que o hábito alimentar desempenha um papel central para a saúde, o que torna importante o conhecimento do padrão alimentar nesta faixa etária. Para a avaliação da ingestão alimentar média a longo prazo em grande número de indivíduos, os Questionários de Frequência de Alimentos (QFAs) são instrumentos particularmente importantes. Objetivo: validar um questionário de frequência alimentar para idosos saudáveis. Casuística e Métodos: Participaram da pesquisa 43 idosos independentes, com a capacidade cognitiva e funcional preservadas, de ambos os gêneros, com idades > 60 anos. Foi avaliado o consumo alimentar dos indivíduos por meio de 3 recordatórios alimentares de 24 horas e um questionário de frequência alimentar, com o auxílio de um livro de fotografias para visualização do tamanho das porções dos alimentos. Como método padrão-ouro, foi utilizada a água duplamente marcada (DLW) para aferição do gasto energético total diário. Para a análise estatística, foi realizada análise descritiva dos dados, calculado o coeficiente de correlação de Spearman, construídos gráficos de dispersão e de Bland-Altman, e também o Coeficiente de Correlação Intraclasse (ICC). Foi adotado o nível de significância de 5%. Resultados: foi observada excelente concordância entre o QFA e DLW para estimativa do consumo de energia em mulheres idosas, assim boa correlação entre o R24h e DLW para estimativa do consumo de energia em homens idosos. Não foram encontradas correlações significativas entre o QFA e DLW para estimativa do consumo de energia em ambos os sexos. Conclusão: Considerando que o objetivo desta pesquisa foi validar o QFA para os dois gêneros (homem e mulher), o mesmo não foi alcançado. / Introduction: It is expected that between 2010 and 2050, the total world population will increase by 2 billion inhabitants, while the elderly population will reach 1.3 billion. Among the many factors involved in long life expectancy, it is well established that eating habits play a central role in health, which makes it important to know the food pattern in this age group. For the evaluation of the long-term average food intake in a large number of individuals, Food Frequency Questionnaires (FFQs) are particularly important instruments. Objective: to validate a food frequency questionnaire for healthy elderly. METHODS: Participants were 43 independent, with cognitive and functional capacity, of both genders, aged> 60 years. The individuals\' food consumption was evaluated through three 24-hour recalls and a food frequency questionnaire, with the aid of a photo book to visualize the size of the food portions. As a gold standard method, double-labeled water (DLW) was used to measure total daily energy expenditure. For the statistical analysis, a descriptive analysis of the data was performed, the Spearman correlation coefficient was calculated, the dispersion and Bland-Altman graphs were constructed, as well as the Intraclass Correlation Coefficient (ICC). The significance level of 5% was adopted. Results: excellent concordance was observed between the QFA and DLW for estimation of energy consumption in elderly women, thus a good correlation between R24h and DLW for estimation of energy consumption in elderly men. No significant correlations were found between the QFA and DLW to estimate the energy consumption in both sexes. Conclusion: Considering that the objective of this research was to validate the FFQ for both genders (man and woman), the same was not achieved.
30

Avaliação antropométrica, da composição corporal, gasto energético em repouso e do perfil inflamatório em mulheres em uso de acetato de medroxiprogesterona de depósito / Anthropometric, body composition, resting energy expenditure and inflammatory status in women using depot medroxyprogesterone acetate

Batista, Gisele Almeida, 1989- 26 August 2018 (has links)
Orientador: Sarah Monte Alegre / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-26T08:26:23Z (GMT). No. of bitstreams: 1 Batista_GiseleAlmeida_M.pdf: 1859346 bytes, checksum: 3cb1bc28cbd20d9ddb7e8e3a58874a1e (MD5) Previous issue date: 2014 / Resumo: Introdução: O acetato de medroxiprogesterona de depósito (AMPD, Depoprovera®) é um método contraceptivo de alta eficácia e segurança; seu uso tem se difundido amplamente e vem sendo utilizado por milhões de mulheres. Existem poucos estudos na literatura sobre o gasto energético em repouso nas usuárias de Depoprovera®, e é possível que existam variações especialmente naquelas que ganham peso em uso do método. Objetivo: Avaliar as alterações no peso, composição corporal e gasto energético em repouso de mulheres em uso de acetato de medroxiprogesterona de depósito e DIU TCu 380 no período de 12 meses. Métodos: Estudo prospectivo com 20 usuárias de Depoprovera® e 17 usuárias de DIU TCu380, como controle, no período de um ano. Mulheres atendidas no ambulatório de Planejamento Familiar do CAISM/UNICAMP em idade fértil, que optaram como método contraceptivo o injetável Depoprovera®, sem uso prévio deste método, e que apresentavam Índice de Massa Corporal (IMC) < 30 kg/m², além de mulheres que utilizavam o método contraceptivo não hormonal DIU TCu 380A foram convidadas a participar do estudo. Resultados: Os grupos foram pareados no período basal, tornando-se um grupo homogêneo em relação a peso, idade e IMC. Após 12 meses de avaliação, pode-se observar aumento de peso, IMC e superfície corporal de forma significativa no grupo Depo. Em relação ao gasto energético em repouso e quociente respiratório, houve aumento significativo da taxa metabólica basal nos dois grupos. O quociente respiratório reduziu de forma significante nos dois grupos. Quando o grupo Depo foi subdividido por ganho de peso, o subgrupo que ganhou < 3 kg após 12 meses teve aumento significativo de peso, IMC, superfície corporal e quociente respiratório, já o subgrupo que ganhou > 3 kg aumentou significativamente peso, IMC, superfície corporal, peso de massa magra, peso de massa gorda, taxa metabólica basal, Leptina, HOMA-IR e circunferência da cintura e reduziu quociente respiratório após os 12 meses de acompanhamento. Conclusão: Nosso estudo encontrou alterações relevantes no peso, composição corporal e perfil metabólico da população estudada nos primeiros 12 meses de uso do contraceptivo. Essas alterações principalmente o aumento de peso corporal, aumento dos níveis de leptina e HOMA-IR, podem contribuir para o desenvolvimento de algumas complicações crônicas, entre elas a obesidade, resistência à insulina e diabetes mellitus / Abstract: Introduction: Depot Medroxyprogesterone Acetate (DMPA, Depoprovera®) is an high contraceptive efficacy and safety; its use has spread broadly and has been used by millions of women. There are few studies on the resting energy expenditure in Depoprovera® users, and it is possible that there are variations especially those who gain weight using the method. Objective: To evaluate the changes in weight, body composition and resting energy expenditure in women using depot medroxyprogesterone acetate and IUD TCu 380 in 12 months. Methods: This was a prospective study with 20 Depoprovera® users and 17 IUD users TCu380 as a control within one year. Women attending the outpatient clinic of CAISM / UNICAMP of childbearing age who chose the injectable contraceptive Depoprovera ® without previous use of this method, Body Mass Index (BMI) < 30kg / m², and women using non-hormonal contraception IUD TCu 380, were invited to participate in the study. Results: The groups were paired at baseline, becoming a homogeneous group in relation to age (± 1 year), and BMI (+1 kg/m²). After 12 months of evaluation, we could observe a significant increase in the DMPA group in weight, BMI and body surface. Relative to resting energy expenditure and respiratory quotient, there was an increase of baseline metabolic rate in both groups after one year. The respiratory quotient was significantly reduced after 12 months in groups DMPA and IUD. The sub-group DMPA that gained < 3kg had increased significant weight, BMI and body surface with respiratory quotient reduction, while the sub-group that gained > 3kg had a significant increase in weight, BMI, body surface, free fat mass, fat mass, baseline metabolic rate, Leptin, HOMA-IR and waist circumference, with respiratory quotient significantly reduced. Conclusion: Our study found significant changes in weight, body composition and metabolic profile of the population studied in the first 12 months of contraceptive use. These changes mainly increased body weight, leptin levels and HOMA-IR which can contribute to the development of some chronic complications, including obesity, insulin resistance and diabetes mellitus / Mestrado / Clinica Medica / Mestra em Clínica Médica

Page generated in 0.4529 seconds