• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 9
  • 9
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Emprego da técnica MF-HG-AAS na determinação de estanho : análise de parâmetros analíticos e morfológicos do atomizador metálico / Employment of a metallic furnace hydride generation atomic absorption spectrometry (MF-HG-AAS) method for tin determination : analytical and morphological parameters analysis of metallic atomizer

Galazzi, Rodrigo Moretto, 1988- 22 August 2018 (has links)
Orientador: Marco Aurélio Zezzi Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-22T10:57:39Z (GMT). No. of bitstreams: 1 Galazzi_RodrigoMoretto_M.pdf: 2262907 bytes, checksum: fb6e92051f6858cd925c525071ce6540 (MD5) Previous issue date: 2013 / Resumo: Nessa dissertação, otimizou-se um método para a determinação de estanho (Sn) em amostras biológicas empregando a técnica de Espectrometria de Absorção Atômica por Geração de Hidretos e Forno Metálico (MF-HG-AAS, do inglês Metallic Furnace Hydride Generation Atomic Absorption Spectrometry). Foram avaliadas algumas variáveis químicas como o tipo e concentração do carregador/diluente da solução padrão, concentração do redutor tetraidridoborato (-1) de sódio (THB) e concentração de hidróxido de sódio, bem como variáveis físicas do sistema dentre elas a vazão de carregador, proporção de acetileno:ar na chama, volume de solução injetado, vazão de argônio como gás de arraste, vazão de água no nebulizador e área total de furos no tubo metalico Inconel600®. Foi realizado um estudo do efeito de memória observado em condições de chama oxidante nas vazões de 1,5:9; 1,4:9; 1,3:9; 1,4:10; 1,4:8 e 1,5:11 L min de acetileno:ar, respectivamente. Em todas essas proporções de chama diferentes da otimizada (1,5:10 L min acetileno:ar) há efeito de memória, o que é extremamente indesejável. Após a otimização do sistema, foram realizados testes de exatidão e precisão do mesmo com os materiais PACS-2 (sedimento) e SRM 1643e (amostra de água) em que, em ambos, foi possível recuperar o Sn adicionado obtendo limites de detecção (LD) de 7,1 mg kg e 7,6 mg L, respectivamente. Um estudo com concomitantes foi realizado para avaliar se algum dos elementos em questão poderia interferir na determinação do Sn. Foram estudados como possíveis concomitantes o cobre, chumbo e zinco em três níveis diferentes. Somente o cobre, nas razões de 1:10 e 1:20 (Sn:concomitante), interferiu na detecção de Sn. Por fim, a morfologia do atomizador foi avaliada por meio da técnica de Microscopia Eletrônica de Varredura (SEM, do inglês Scanning Electron Microscopy). Mesmo após a realização de todos os experimentos envolvendo a otimização do sistema e análise das amostras, os principais constituintes do tubo metálico Inconel600® (ferro, níquel e cromo) permaneceram homogeneamente distribuídos, indicando que esses metais podem não participar da rota de atomização do Sn. Além disso, houve formação de óxidos no atomizador que, juntamente com o uso de uma chama oxidante, sugerem uma rota de atomização do Sn via formação de óxidos. Considerando os LD, bem como a exatidão e precisão por meio da recuperação de Sn obtida nas amostras, constata-se a potencialidade da MF-HG-AAS frente a outras técnicas empregadas na determinação de Sn / Abstract: In this work, a Metallic Furnace Hydride Generation Atomic Absorption Spectrometry (MF-HG-AAS) was optimized for tin (Sn) determination in biological samples. Chemical variables, such as the type and carrier concentration, the sodium tetrahydrideborate (-1) (THB), and the sodium hydroxide concentration, as well as physical variables, such as carrier flow-rate, ratio of acetylene and air in the flame, injection volume, argon flow-rate as carrier of stannane, water flow-rate in nebulizer and total hole area of a Inconel600® metallic furnace were evaluated. A study of a memory effect observed in oxidant flame conditions such as 1.5:9; 1.4:9; 1.3:9; 1.4:10; 1.4:8 e 1.5:11 L minof acetylene:air, respectively, was realized. In any other flame flow-rate, which the optimized flame ratio (1.5:10 L min acetylene:air) was observed a memory effect, which is very undesirable. After optimizing of the system, test of accuracy and precision were realized with the PACS-2 (sediment) and SRM 1643e (water sample) materials wherein, in both, a recovery of the Sn added to the samples was possible with limits of detection (LOD) as 7,1 mg kg and 7,6 mg L, respectively. A concomitant study was carried out for checking the interferences in the Sn determination. Copper, lead and zinc at three different levels were studied as possible concomitants. Only copper, at 1:10 and 1:20 (Sn:concomitant) ratios interfered in the determination of Sn. Finally, the morphology of the atomizer employed was evaluated through Scanning Electron Microscopy (SEM) technique. Even after carrying out all experiments involved in the optimization of the system and in the sample analysis, the main constituents of Inconel600® metallic furnace (iron, nickel and chromium) remained homogeneously distributed, indicating which these elements may not participate of the Sn atomization route. Moreover, the oxide formation in the atomizer was detected, which, together with an oxidant flame used, suggests the Sn atomization route via oxides formation. Considering the LOD, as well the accuracy and precision through the Sn recovery in the samples, the MF-HG-AAS potentially is well pointed out when it is compared to other techniques employed for Sn determination / Mestrado / Quimica Analitica / Mestre em Química
2

Determinação de As, Sb e Se em material agronômico por espectrometria de emissão óptica acoplada a plasma induzido com geração de hidretos (HG-ICP-OES). / Determination of As, Sb and Se in agronomic samples by hydride generation inductively coupled plasma optical emission spectrometry.

Crispino, Carla Cripa 07 April 2005 (has links)
Made available in DSpace on 2016-06-02T20:36:57Z (GMT). No. of bitstreams: 1 DissCCC.pdf: 1000443 bytes, checksum: ddedf64b615b10f0a375f5b68b3da175 (MD5) Previous issue date: 2005-04-07 / Financiadora de Estudos e Projetos / With the objective to attain maximum productivity with small costs, organic and inorganic chemical parameters are used to evaluate and monitoring crops and animals development. Inorganic amounts in agronomic samples have great importance in the production evaluation. Some of elements in those samples could be an indicative of quality, owing to their requirement (Se) or toxicity (As, Sb), even when they are present in µg kg-1 levels, needing a technique with high sensibility for quantification. The aim of this work was the development of a simple system of hydride generation by continuous flow combined with an inductively coupled plasma optical emission spectrometry for simultaneous determination of As, Sb and Se in agronomic samples. The work attained to a gas-liquid separator development, and an experimental planning to established the chemical and instrumental conditions of hydride generation. The HCl, NaBH4 and KI concentrations, such as the R.F. power, carrier gas flow and the viewing height, were evaluated besides the study of a more appropriate sample preparation. Limits of detection of the proposed system were 0.1 µg L-1 for As, Sb and Se and the limits of quantification were 0.3, 0.2 and 0.2 µg L-1 for As, Sb and Se respectively with RSD smaller than 10% and 30 samples per hour of reading speed. In view to observe the accuracy, four different kinds of samples forage and bovine-derived samples (blood, viscera and semen) were spiking with analytes concentration in the µg L-1 level. Recoveries around 77 to 112% were found. The results present the possibility to use the proposed system in agronomic projects developed with the objective to determine essential and toxic analytes in different kinds of feed and animal samples, contributing to evaluation of nutritional demands and the increase of efficiency in the bovine production systems. / Com o objetivo de atingir a maior produtividade com menores custos, parâmetros químicos, orgânicos e inorgânicos, são usados cada vez mais para avaliar e monitorar o desenvolvimento de uma cultura ou espécie. A determinação de constituintes inorgânicos em amostras agronômicas possui grande importância na avaliação da produção. Alguns elementos presentes nessas amostras são indicativos da qualidade devido à essencialidade (Se) ou toxicidade (As, Sb), porém estão presentes na ordem de µg kg-1, necessitando de uma técnica com alta sensibilidade para quantificação. O objetivo deste trabalho foi o desenvolvimento de um sistema simples de geração de hidretos por fluxo contínuo acoplado a um espectrômetro de emissão óptica com plasma induzido para a determinação simultânea de As, Sb e Se em amostras agronômicas. Esse trabalho envolveu o desenvolvimento de uma câmara de separação gás-líquido e um planejamento experimental para a definição das melhores condições químicas e instrumentais da geração de hidretos. Foram estudadas a concentração de HCl, NaBH4 e KI; a potência de radiofreqüência do plasma, o fluxo do gás carregador e a altura de observação do plasma, além do estudo do preparo de amostra mais adequado. Usando as condições otimizadas, foram obtidos limites de detecção de 0,1 µg L-1 para As, Sb e Se e limites de quantificação de 0,3; 0,2 e 0,2 µg L-1 respectivamente para As, Sb e Se com RSD menores que 10% e velocidade de leitura de 30 amostras por hora. Para observar a exatidão do procedimento proposto quatro amostras diferentes - forrageira e amostras bovinas (sangue, víscera e sêmen) - foram dopadas com os analitos na ordem de µg L-1. Recuperações entre 77 e 112% foram encontradas. Espera-se com essa proposta a complementação dos estudos que determinam analitos essenciais e tóxicos em amostras de tecido, fluídos e na alimentação bovina, contribuindo para a avaliação das exigências nutricionais e o aumento da eficiência dos sistemas de produção de bovinos.
3

Metodologia para determinação de arsênio, antimônio e bismuto por espectrometria de emissão óptica com fonte de plasma acoplado indutivamente (ICPOES) e geração de hidretos aplicada à rochas

Borges, Elisa Moura [UNESP] 06 May 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-05-06Bitstream added on 2014-06-13T19:33:35Z : No. of bitstreams: 1 borges_em_me_rcla.pdf: 583445 bytes, checksum: a94bcee1df858747cf63f7c61d62429e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / No presente trabalho são descritas as etapas para o desenvolvimento de uma metodologia para determinação de arsênio, antimônio e bismuto em materiais geológicos, utilizando gerador de hidretos acoplado ao ICPOES, proporcionando a determinação dos elementos de interesse em baixas concentrações. O método é sensível, por isso está sujeito a interferências, como as causadas por elementos presentes na matriz. Foram realizadas otimizações nos parâmetros operacionais e analíticos do equipamento, que visaram uma melhor sensibilidade e um método eficiente de solubilização completa de amostra de rocha, que permita a determinação dos elementos de interesse em baixas concentrações. Para a etapa de validação do método foram realizados diversos ataques com adições de padrão e testes com o uso de tiouréia e iodeto de potássio com ácido ascórbico em diferentes concentrações com o objetivo de minimizar possíveis interferências presentes na matriz. Os resultados finais foram obtidos através da solubilização de materiais de referência internacionais geológicos na determinação de arsênio, bismuto e antimônio e se mostraram satisfatórios. / In this study, the steps for the development of a methodology to the determination of arsenic, antimony and bismuth in geological materials, with the use of hydride generation and ICPOES are being described. The methodology is sensitive due to that, subject is bound to suffer interferences from matrix elements. Optimizations in operations and analyticals parameters were done in the equipment. They aimed a better sensitivite and an efficient method of complete dissolution techniques in a sample of rock, which permits the determination of the analyte in low concentrations. For the steps of methodology validation, many dissolutions were realized with the addition of standard and tests with the use of thiourea and KI and acid ascorbic in different concentrations with the objective of minimizing some interferences from matrix elements. The final results were obtained through dissolutions with international reference materials in the determination of arsenic, antimony and bismuth.
4

Avaliação de estratégias analíticas para reduzir interferências em ICP-MS e ICP OES / Evaluation of analytical strategies to reduce interferences in ICP-MS and ICP OES

Bianchi, Silmara Rossana 05 August 2011 (has links)
Made available in DSpace on 2016-06-02T20:34:28Z (GMT). No. of bitstreams: 1 3868.pdf: 6248664 bytes, checksum: 10f3f9177a7071704531908c4e0d055c (MD5) Previous issue date: 2011-08-05 / Universidade Federal de Minas Gerais / Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES) are widely multi-element techniques used to analysis complex samples. Otherwise some aspects, such as spectral interferences and low transport efficiency due to pneumatic nebulization limit their applications. In this work the use of the collision-reaction interface (CRI) of ICP-MS in sequential extraction of the As, Cd, Cr, Cu, Pb, V and Zn in sample of soil treated with vinasse for removal of polyatomic interferences and online hydride generation using a Flow Blurring® multinebulizer for the elimination of matrix interferences and improvement of transport efficiency in determining the As, Sb, Se and Sn by ICP OES have been evaluated. In the evaluation of the CRI, it was found that the flow rates of 60 mL min-1 of H2 and 80 mL min-1 of He introduced into the skimmer cone were the flow rates that showed better efficiency in the correction of interferences and was necessary to perform the inorganic matrix matching (majoritarian elements) of the calibration curve and blanks. The sequential extraction of soil samples treated with vinasse showed that the addition this residue contributes to the increase in the concentration of Cu in exchangeable fraction. The proposed method for hydride generation uses an integrated system, in which the formation of volatile species occurs by interaction of aerosols generated by the different multinebulizer orifices in the ICP-OES spray chamber, without the need of any special system. To this end, two of the three multinebulizer orifices are used to continuously nebulize acid and reducing agent, respectively, while the third one is used to sample introduction. The system was optimized to obtain the highest sensitivity using factorial designs. Interference effects of transition metals were corrected by addition of thiourea. The accuracy of the method was verified by determination of antimony, arsenic, selenium and tin in standard reference materials. / Espectrometria de massa com plasma acoplado indutivamente (ICP-MS) e espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES) são técnicas multielementares muito usadas na análise de amostras complexas, porém aspectos como interferências espectrais e baixa eficiência de transporte devido à nebulização pneumática limitam suas aplicações. Neste trabalho foram avaliadas a utilização da interface de reação e colisão (CRI) de ICP-MS na extração sequencial de As, Cd, Cr, Cu, Pb, V e Zn em amostras de solos tratados com vinhaça para remoção das interferências poliatômicas, e geração de hidretos on line usando um multinebulizador Flow Blurring® para a eliminação de interferências de matriz e melhora da eficiência de transporte na determinação de As, Sb, Se e Sn por ICP OES. Na avaliação da CRI, verificou-se que as vazões de 60 mL min-1 de H2 e 80 mL min-1 de He introduzidos no cone skimmer foram as vazões que apresentaram melhor eficiência na correção de interferentes, e que é necessário realizar a compatibilização inorgânica (elementos majoritários) da curva de calibração e dos brancos. A extração sequencial das amostras de solo tratados com vinhaça mostrou que a adição desse resíduo contribui somente para o aumento no teor de Cu na fração trocável. O método proposto para a geração de hidretos utiliza um sistema integrado no qual a formação das espécies voláteis ocorre pela interação dos aerossóis gerados por diferentes orifícios do multinebulizador na câmara de nebulização de ICP OES, sem a necessidade de sistemas especiais. Para isso, dois dos três orifícios do multinebulizador são usados para a nebulização contínua de ácido e agente redutor, respectivamente, enquanto o terceiro é usado para a introdução da amostra. O sistema foi otimizado para obter a maior sensibilidade utilizando experimentos fatoriais. Efeitos de interferência de metais de transição foram corrigidos pela adição de tiouréia. A precisão do método foi comprovada por determinação de antimônio, arsênio, selênio e estanho em materiais de referência certificados.
5

Determinação sequencial rápida de As e Sb, Bi e Pb por espectrometria de absorção atômica com geração de hidretos / Fast sequential determination of as and sb, bi and pb by flame atomic absorption spectrometry with hydride generation

Batista, Érica Ferreira 22 March 2012 (has links)
Made available in DSpace on 2016-06-02T20:36:38Z (GMT). No. of bitstreams: 1 4337.pdf: 2480457 bytes, checksum: 2ba093ad45a1d2cc0ed3b023664c1c12 (MD5) Previous issue date: 2012-03-22 / Universidade Federal de Sao Carlos / In this study it was developed two systems, one for the fast sequencial determination of As and Sb and other for Bi and Pb using flame atomic absorption spectrometry with hydride generation. To optimize the system for the determination of As (193.7 nm) and Sb (217.6 nm) some variables were evaluated: concentration (in mol L-1) of HCl in the sample and carrier, concentrations (in % w v-1) of KI and NaBH4. For the system used in the determination of Bi (223.1 nm) and Pb (217.0 nm) the following variables were studied: concentration (in mol L-1) of HCl in the sample, concentrations (in % w v-1) of K3Fe(CN)6 and NaBH4. For these studies it was employed Doehlert design to select the best work conditions and obtain more information of the proposed methods. Some analytical parameters were obtained, respectively, for As, Sb, Bi and Pb: Limits of detection (LOD) (0.15; 0.16; 0.60 e 0.77 μg L-1), repeatability (RSD) (1.5; 2.0; 5.9; 6.0 %) and correlation coefficients (r) (0.999; 0.999; 0.998 e 0.997). In order to identify species that could interfere in the determination of As and Sb, Bi and Pb, a study was carried out considering the constituents commonly found in natural waters and chicken feed including Al(III), Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Ni(II) and Zn(II). It was also carried out a study to investigate the influence of the concentration of HNO3 in the As and Sb, Bi and Pb determinations. Through studies with possible interferences, can be observed that there were no significant trend for As, Sb and Bi, the percentage of interference was lower than 21% (contrasts from -4 to 5% for both analytes). In the case of Pb it was noted a strong signal interference by Co (II), Cu (II), Fe (III) and Ni (II) with contrasts varying from -62 % to 29%. The effect of HNO3 concentration was not relevant if it is lower than 10 % v v-1 for As, Sb and 20 % v v-1 for Bi. However, it was noted a strong Pb signal suppression for HNO3 concentrations higher than 0.25 % v v-1. The systems developed were applied in the determination of As and Sb, Bi and Pd in Tietê river water, sea water of Praia Grande Ubatuba, chicken feed and to validate the methods were used two certificate reference materials: Nist 1643e (Trace elements in water) e TMDW-HPS (Trace metals in drinking water). / Neste trabalho foram desenvolvidos dois sistemas, um para a determinação sequencial rápida de As e Sb, e outro para a determinação sequencial rápida de Bi e Pb utilizando a espectrometria de absorção atômica com chama com geração de hidretos. Na otimização do sistema para a determinação de As (193,7 nm) e Sb (217,6 nm) foram estudadas variáveis como: concentrações (em mol L-1) de HCl da amostra e do carregador, concentrações (em % m v-1) de KI e de NaBH4. Para o sistema utilizado na determinação de Bi (223,1 nm) e Pb (217,0 nm) foram estudadas as variáveis: concentração (em mol L-1) de HCl da amostra, concentrações (em % m v-1) de K3Fe(CN)6 e do NaBH4. Para esses estudos fez-se uso de um planejamento Doehlert, com o intuito de identificar os melhores parâmetros e extrair uma maior quantidade de informações dos métodos propostos. Alguns parâmetros analíticos foram obtidos, respectivamente para As, Sb, Bi e Pb: Limite de detecção (LD) (0,15; 0,16; 0,60 e 0,77 μg L-1), repetibilidade (RSD) (1,5; 2,0; 5,9; 6,0 %) e coeficiente de regressão (r) (0,999; 0,999; 0,998 e 0,997). Com o intuito de identificar os interferentes em potencial na determinação dos analitos, foi realizado um planejamento fatorial fracionário 28-4 com os possíveis elementos interferentes encontrados em amostras de águas do rio e do mar e em ração de frango: Al(III), Co(II), Cr(VI), Cu(II), Fe(III), Mn(II), Ni(II), e Zn(II). Foi realizado também um estudo para averiguar a influência da concentração de HNO3 nas determinações de As e Sb, Bi e Pb. Através dos estudos com possíveis interferentes, pôde-se observar que não houve nenhuma tendência significativa para As, Sb e Bi, sendo a porcentagem de interferência inferior a 21 % (contrastes de -4 a 5 %). No caso do Pb houve alteração no sinal causados pelo Co (II), Cu (II), Fe (III) e Ni (II) com contrastes de -62 % a 29 %. O efeito da concentração do HNO3 não se mostrou relevante quando inferior a 10 % v v-1 para As e Sb e 20 % v v-1 para Bi. Entretanto, uma forte supressão no sinal analítico do Pb foi observada para concentrações de HNO3 superiores a 0,25 % v v-1. Os sistemas desenvolvidos foram aplicados na determinação de As e Sb, Bi e Pb em água do rio Tietê, água do mar da Praia Grande- Ubatuba, ração de frango e para validar os métodos foram utilizados dois materiais de referência certificados: Nist 1643e (Trace elements in water) e TMDW-HPS (Trace metals in drinking water).
6

Determinação das concentrações biodisponíveis de arsênio e selênio em amostras de sedimentos por espectrometria de emissão ótica com fonte de plasma utilizando o CMA (analisador concomitante de metais) para geração de hidretos e mimização de interferências

Lopes, Watson da Luz 28 February 2018 (has links)
Submitted by Biblioteca de Pós-Graduação em Geoquímica BGQ (bgq@ndc.uff.br) on 2018-02-28T17:03:22Z No. of bitstreams: 1 Dissertação de Watson Lopes.pdf: 460692 bytes, checksum: 84daa08fc121a4dab8c57c36f24c8b2d (MD5) / Made available in DSpace on 2018-02-28T17:03:23Z (GMT). No. of bitstreams: 1 Dissertação de Watson Lopes.pdf: 460692 bytes, checksum: 84daa08fc121a4dab8c57c36f24c8b2d (MD5) / Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Universidade Federal Fluminense. Instituto de Química. Programa de Pós-Graduação em Geoquímica, Niterói, RJ / Neste trabalho, foram desenvolvidos procedimentos analíticos para a determinação das concentrações biodisponíveis de arsênio e selênio em sedimentos por espectrometria de emissão ótica com fonte de plasma indutivamente acoplado, utilizando o método de geração de hidretos com o CMA (analisador concomitante de metais) e a metodologia recomendada pela US EPA (Agência de Proteção Ambiental dos Estados Unidos) para o preparo das amostras pelo método 3051. O CMA é um gerador de hidretos usado para determinar, concomitantemente, o maior número de elementos (formadores e não formadores de hidretos), em uma única análise. Ele consiste em um sistema com nebulizador pneumático e uma câmara ciclônica especial, capaz de transportar os elementos formadores e os não formadores de hidretos, simultaneamente, sem perda de sensibilidade. As condições experimentais foram otimizadas para se obter a melhor performance de operação do CMA como gerador de hidretos. Dentre estas condições podemos citar: vazão do gás do plasma, vazão do “gás de envoltório”, vazão da amostra, vazão da solução de NaBH4, vazão da solução do ácido clorídrico, concentrações de NaBH4 e do ácido e pressão do gás de nebulização. Para minimizar as interferências produzidas pelos íons de metais de transição (Cd2+, Co2+, Cu2+, Fe3+ e Ni2+) na determinação de arsênio e selênio foi utilizada alta concentração de HCl para a geração de hidretos e a validação do método foi obtida através da análise de uma amostra de referência certificada ( lama industrial NIST-SRM 2782) e de uma amostra com valor informado ( sedimento NIST-SRM 8704). / An analytical procedure was developed in this work for the determination of bioavailable concentrations of arsenic and selenium in sediment samples by inductively coupled plasma optical emission spectrometry using hydride generation, employing a concomitant metal analyzer (CMA) and the US EPA (Environmental Protection Agency from USA) 3051 method for sample preparation. The CMA is a hydride generator that can be used to determine hydride and nonhydride forming elements in a single run. This system consists of a pneumatic nebulizer coupled to a special cyclonic chamber, in which the aerosol containing both hydride forming and non-forming elements are transported towards the ICP torch and the measurements can be done without sensitivity losses. The experimental conditions were optimized in order to obtain best CMA operational performance as a hydride generator. Several variables were studied such as: plasma gas, sheath gas, sample, sodium borohydride, hydrochloric acid flow rates as well as borohydride and hydrochloric acid concentrations and nebulization pressure. For minimization of interference due to transition metal ions (Cd2+, Co2+, Cu2+, Fe3+ and Ni2+) to the arsenic and selenium signals, a higher hydrochloric acid concentration was used for the hydride generation, and the procedure was validated by the analysis of certified reference material (NIST-SRM 2782 industrial sludge) and reference material (NIST-SRM 8704 sediment).
7

Ampliando as potencialidades da tecnica de geração de hidretos / Extending the potentialities of the hydride generation technique

Figueiredo, Eduardo Costa de 18 July 2005 (has links)
Orientador: Marco Aurelio Zezzi Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-04T22:53:39Z (GMT). No. of bitstreams: 1 Figueiredo_EduardoCostade_M.pdf: 5877197 bytes, checksum: d13ecbeef095d45a61dd1d47fe72de84 (MD5) Previous issue date: 2005 / Mestrado / Quimica Analitica / Mestre em Química
8

Desenvolvimento de procedimentos para determinação de As e Se em organismos marinhos por espectrometria de absorção atômica com geração de hidretos e amostragem de suspensão (SLS-HG AAS)

Carioni, Vivian Montes de Oca January 2010 (has links)
Orientadora: Cassiana Seimi Nomura. / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Ciência e Tecnologia/Química, 2010.
9

Avaliação de um sistema FI-HG-MF-AAS e extração assistida pro micro-onda na especiação de arsênio inorgânico / Evaluation of a FI-HG-MF-AAS system and microwave-assisted extraction on inorganic arsenic speciation

Lehmann, Eraldo Luiz, 1981- 20 August 2018 (has links)
Orientadores: Marco Aurélio Zezzi Arruda, Anne-Hélène Fostier / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-20T06:38:49Z (GMT). No. of bitstreams: 1 Lehmann_EraldoLuiz_M.pdf: 2472831 bytes, checksum: 9197e3f8344d1f42efcc6e44cd1ffe01 (MD5) Previous issue date: 2012 / Resumo: Nessa Dissertação foram avaliados um sistema de injeção em fluxo com geração de hidretos acoplado a um espectrômetro de absorção atõmica com atomizador forno metálico de liga Inconel 600® (FI-HG-MF-AAS), bem como a técnica de extração assistida por micro-onda (MAE) como método de preparo de amostra para especiação de arsênio inorgânico. Para o sistema FI-HG-MF-AAS, condições brandas (pH tamponado em 4,5 e concentração de tetraidridoborato(1-) 0,1% (m/v)) foram utilizadas para que apenas a espécie Asi(III) gerasse o seu respectivo hidreto (arsano - AsH3), atingindo-se limites de detecção de 2,0 mg L e quantificação de 6,6 mg L, tornando o método adequado para uso em análises que atendam a portaria de potabilidade de água de acordo com o Ministério da Saúde e Organização Mundial da Saúde (WHO). O Asi(V) não apresentou qualquer sinal nas condições brandas, e apenas o uso de L-cisteína como pré-redutor foi eficiente para sua conversão a Asi(III). O teste de recuperação foi realizado utilizando material de referência NIST 1643e, Traços de elementos em água, com 60,45 mg L de arsênio total. O resultado mostra que Asi(III) não está presente na amostra em concentração acima do limite de detecção, e usando L-cisteína na concentração de 3% (m/v), obteve-se 60,5 mg L de Asi total, atingindo 100% de recuperação. A técnica de extração assistida por micro-onda mostrou-se eficaz para a extração de As total no material certificado de plâncton BCR414, atingindo um nível 93% de recuperação. Também se mostrou eficiente para manter as espécies de As inorgânico (Asi(III) e Asi(V)) inalteradas, sendo assim uma técnica promissora para o preparo de amostras para a análise de especiação / Abstract: In this work a Flow Injection - Hydride Generation - Metallic Furnace - Atomic Absorption Spectrometry (FI-HG-MF-AAS) system was evaluated, using an Incone600 ® alloy tube as a metallic oven, as well as the technique of microwave-assisted extraction (MAE) for sample preparation aiming speciation of inorganic arsenic. For the FI-HG-MF-AAS system, mild conditions (buffered media at pH 4.5 and concentration of tetrahydridoborate (1-) 0.1% (m/v)) allow that only iAs(III) generates hydride (arsane - AsH3), reaching a detection limit of 2.0 m gL and limit of quantification of 6.6 mg L, making suitable for its use in analysis according to Brazilian's Ministry of Health and World Health Organization (WHO) for drinking water. The inorganic As(V) did not show signal in mild conditions, and only the use of L-cysteine as pre-reducing agent was efficient in its conversion to inorganic As(III). The recovery test was carried out using reference material NIST 1643e, Trace elements in water, with 60.45 mg L of total arsenic. The result shows that inorganic As(III) is not present at concentration above the limit of detection, and using L-cysteine 3% (w/v), was obtain a total inorganic As concentration of 60.5 mg L, reaching a recovery of 100%. Microwave-assisted extraction technique was effective for the extraction of the total arsenic in certified plankton BCR414material, reaching a recovery level of 93%. Additionally, it also proved to be effective in preserving the species of unchanged inorganic arsenic, making it a promising technique for sample preparation aiming a speciation analyzes / Mestrado / Quimica Analitica / Mestre em Química
10

Determinação de As, Bi, Sb, Se, Sn e Te por injeção em fluxo com geração de hidretos acoplada a espectrometria de massa com plasma indutivamente acoplado

Soares, Jocelene 23 July 2010 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / In this work it is proposed the development of flow injection systems for hydride generation coupled to inductively coupled plasma mass spectrometry (FI-HG-ICPMS) for determination of trace elements (As, Bi, Sb, Se, Sn and Te) in lead alloys employed in automotive battery. Due to the characteristics of the sample matrix, manly the presence of high concentrations of lead that can interfere in hydride generation technique, a detailed investigation of the influence of the physical and chemical parameters was made. The carrier solution concentration (HCl) reductant concentration (NaBH4 solution), reaction coil length and sample volume were evaluated. As the ICP-MS is a multielmentar technique, the parameters were optimized in order to determine simultaneously the highest number of elements. Three different configurations of FI systems were tested: a) a single channel system; b) a two channel system with one gas/liquid separator; and, c) a two channel system with two gas/liquid separators. According to the characteristics of the elements, two groups were separated: one group containing As, Bi, Se and Te were 6.0 mol l-1 HCl is necessary as sample carrier solution and another group containing Sb and Sn were 0.1 mol l-1 HCl is used as sample carrier. The compromise conditions of NaBH4 concentration, carrier gas (Ar) flow rate, sample volume and reactor coil length were 0.6% (m/v), 1.25 L min-1, 87 μL and 50 cm, respectively, for both groups of elements. Both systems with two reaction channels allow the simultaneous determination of the two groups of elements. Strong analyte signal suppression in presence of Pb, Ag, Bi and Cu was observed. However, the interference could be overcome by using the optimized conditions for hydride generation. By using the proposed FI-HG-ICP-MS systems it was possible to determine relatively low concentrations of Bi, Sb, Se, Sn and Te in lead alloys. The limits of detection were 0.34, 0.01, 0.01, 0.01, 0.01, 0.01 mg g-1 of As, Bi, Sb, Se, Sn and Te, respectively. The accuracy of the developed method was evaluated by using analyte recovery tests where the results were in range 94 to 103%. / Neste trabalho foram desenvolvidos sistemas de injeção em fluxo (FI) para a geração de hidretos (HG) acoplados a espectrometria de massa com plasma indutivamente acoplado (FI-HG-ICP-MS), para a determinação de elementos traço em liga de chumbo empregada em baterias automotivas. Devido às características da matriz da amostra, principalmente devido a presença de Pb, foi feita uma investigação detalhada dos parâmetros físicos e químicos da HG como, a concentração da solução carregadora (HCl), concentração do redutor, comprimento do reator e o volume de amostra injetado. Para a eficiente geração dos hidretos voláteis foi necessário estabelecer uma condição de compromisso. Desta forma, para As, Bi, Se e Te foi usada como solução carregadora da amostra HCl 6,0 mol L-1 e HCl 0,1 mol L-1 para Sb e Sn. A concentração de NaBH4, vazão do gás de arraste (Ar), volume de amostra injetado e o comprimento do reator foram 0,6% (m/v), 1,25 L min-1, 87 μL e 50 cm, respectivamente, para ambos os grupos de elementos. Após estabelecidas as condições reacionais para a geração de hidretos, foram desenvolvidos três sistemas FI. Um sistema FI com um canal de reação e dois sistemas com dois canais de reação, com um e dois separadores gás-líquido. Os sistemas com dois canais de reação permitem a determinação simultânea dos dois grupos de elementos. Forte supressão de sinal foi observada na presença de Pb, Ag, Bi e Cu porém, estas foram contornadas, particularmente, pelas condições reacionais da geração de hidretos e o reduzido volume de amostra injetado. Desta forma, utilizando os sistemas propostos foi possível a determinação de concentrações relativamente baixas para Bi, Sb, Se, Sn e Te em amostras de liga de chumbo. Os limites de detecção obtidos foram de 0,34, 0,01, 0,01, 0,01, 0,01, 0,01 mg g-1 para As, Bi, Sb, Se, Sn e Te, respectivamente. A exatidão do método proposto foi avaliada através de teste de recuperação dos analitos, sendo que os mesmos ficaram na faixa entre 94 e 103%.

Page generated in 0.0726 seconds