• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 10
  • 3
  • Tagged with
  • 26
  • 14
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Interaction lumière-nuage de particules micrométriques hautes vitesses : application à la Vélocimétrie Hétérodyne / Insight into the Photon Doppler Velocimetry response of high-speed micron-sized metallic ejecta cloud

Franzkowiak, Jean-Eloi 29 November 2018 (has links)
Au passage d’un choc sur la surface rugueuse d’un métal, un nuage de débris micrométriques est éjecté. Sa signature spectrale temps-vitesse est mesurée au moyen d’un système optique interférométrique : la Vélocimétrie Hétérodyne (VH).Dans un régime de diffusion simple de la lumière, une étude paramétrique a mis en évidence l’influence des paramètres clés du nuage sur sa réponse Doppler. Nous avons estimé, par Maximum de Vraisemblance, la courbe masse-vitesse d’un nuage d’étain et l’incertitude associée. L’allure de la mesure a également été étudiée en incorporant aux calculs le rendement optique de la sonde.Nous présentons une méthode de calcul Monte Carlo, rendant compte des effets de diffusion multiple. Appliquée à trois expériences d’éjection d’or et d’étain, la présence de vitesses non physiques sur la mesure VH, liée aux diffusions multiples nuage-surface-nuage, a été soulignée, et les décroissances progressives de la visibilité en vitesse et de la puissance rétrodiffusée justifiées. Quelle que soit la masse éjectée, la diffusion multiple doit être intégrée aux calculs, un régime de diffusion simple n’étant valable qu’asymptotiquement, dans les limites d’un temps infini et/ou d’un faisceau sonde de dimension réduite par rapport aux libres parcours moyen de diffusion. / As a shockwave reaches a roughened metal’s surface, high-speed micron-sized particles are ejected. The spectral signature of the cloud can be measured using a fiber-based interferometric setup, so-called Photon Doppler velocimetry (PDV).In the single scattering regime, we study how the parametric dependencies of the cloud influence its Doppler response. Using a Maximum Likelihood technique, we estimate the mass-velocity function of ejected material, and its uncertainty. The time-dependent statistical properties of the spectrum, coming from the complex optical collection efficiency of the probe, are also explained.We present a Monte Carlo method to incorporate multiple scattering. Three different ejecta experiments are studied and the presence of non-physical velocities attributed to multiple scattering between surface and ejecta. Cloud’s visibility and backscattered power decrease with time due to the existence of different scattering regimes. Whatever the ejected mass, multiple scattering effects have to be integrated in PDV calculations. A single scattering will only be asymptotically valid, when time reaches infinity and/or the beam diameter is negligible with respect to the scattering mean free paths.
12

Antenna resonators for quantum infrared detectors and fast heterodyne receivers / Résonateurs-antennes pour détecteurs quantiques Infrarouges et récepteurs rapides à hétérodyne

Palaferri, Danièle 12 February 2018 (has links)
Ce travail de thèse porte sur la conception et la réalisation de méta-structures pour l’amelioration des performances de détecteurs dans les gammes spectrales du moyen infrarouge et du térahertz (THz). Ces méta-structures sont des matrices de résonateurs métalliques qui actent aussi comme antennes, permettant une meilleure collection des photons et un plus fort confinement du champ électrique. Dans ce manuscrit, j’examine les résultats expérimentaux concernant deux photo-detecteurs infrarouges à puits quantiques (QWIP) résonants à une longueur d'onde de 55.5 µm (5.4 THz) et de 8.6 µm, implémentés dans des réseaux d’antennes patch. La responsivité, la détectivité et les performances thermiques des dispositifs en microcavité sont systématiquement comparées au même détecteur fabriqué en géométrie standard ‘mesa’, pour lequel le rayonnement infrarouge est couplé par le substrat. La cohérence du modèle est évaluée en comparant le gain photoconducteur de chaque structure QWIP. Dans le moyen infrarouge, le fonctionnement à température ambiante avec une source de radiation thermique est démontré pour la première fois. De plus, en exploitant la courte durée de vie des porteurs dans la zone de QWIP, une détection hétérodyne à température ambiante a été démontrée jusqu’aux fréquences de quelques GHz, limitée uniquement par la fréquence de coupure du circuit externe. Dans la dernière partie de ce manuscrit, plusieurs perspectives sont discutées concernant des structures de détecteurs quantiques couplés à la géométrie de résonateurs patch et des architectures inspirées des métamateriaux, avec la perspective d’améliorer davantage les performances des photodétécteurs / The present thesis manuscript is about the conception and the realisation of metastructures for the improvement of detector performances in the mid-infrared and terahertz (THz) spectral ranges. These meta-structures are arrays of metal resonators that also act as antennas, allowing a better collection of photons and a stronger confinement of the electric field. In this manuscript, I examine the experimental results regarding a 55.5 µm (5.4 THz) and a 8.6 µm quantum well infrared photodetectors (QWIP), implemented into patch-antennae arrays. The responsivity, the specific detectivity and the thermal performances of the antenna-coupled devices are systematically compared to the same detector processed in standard substrate-coupled ‘mesa’ geometry. In the mid-infrared, the room temperature operation using a thermal radiation source is reported for the first time. Moreover, exploiting the short carrier lifetime in semiconductor quantum wells, a room temperature heterodyne detection is demonstrated, at frequencies up to few GHz, limited only by the cut-off frequency of the external circuit. In the last part of this work, several perspectives are discussed, regarding alternative quantum detector structures coupled to the patch resonators geometry and innovative circuit-like plasmonic architectures, envisioning orders of magnitude improvement in photodetector performances
13

Nano-antennes optiques pour l'inspection des structures photoniques

Abdoulkader Ibrahim, Idriss 16 December 2010 (has links) (PDF)
L'objectif de cette thèse est de concevoir et élaborer des outils innovants, baptisés nano-antennes (NAs), pour sonder le champ électromagnétique optique au voisinage des structures de la nanooptique. Une NA est ici une nanostructure métallique placée à l'extrémité d'une sonde locale fonctionnant en mode collection. Une telle structure joue le rôle de relais entre le champ électromagnétique optique à la surface de l'échantillon et la sonde locale, attribuant à la sonde une sensibilité spécifique vis-à-vis du champ électromagnétique vectoriel. Les nano-antennes seront conçues de manière à fournir une information optique encore inaccessible par le biais de la microscopie en champ proche conventionnelle, pour répondre aux besoins actuels et futurs de la nano-optique. Dans la première partie, nous proposons une nouvelle configuration de sonde locale la nano-ouverture papillon complément d'une nano-antenne papillon et nous exposons sa fabrication aux dimensions spécifiques, à l'extrémité d'une fibre optique en polymère. Dans la deuxième partie, nous présentons une nouvelle configuration de microscopie en champ proche permettant l'accès aux lignes de champs électriques et magnétiques optiques 3D au dessus d'un échantillon, avec une résolution sub-longueur d'onde. Le microscope proposé permet de cartographier simultanément et indépendamment les distributions des amplitudes complexes des deux composantes du champ électrique transverse. La dernière partie est consacrée à l'application d'une méthode numérique dite FDTD afin d'étudier le comportement spectral et l'origine de l'exaltation au niveau de la partie centrale d'une nano-ouverture papillon.
14

Mélangeurs à bolomètres à électrons chauds sur membranes fonctionnant au-delà du THz pour l'instrument post-Herschel

Gay, Gregory 29 November 2013 (has links) (PDF)
Nous avons développé un concept original de mélangeur à bolomètre supraconducteur en structure quasi-optique destiné à la détection hétérodyne dans le domaine térahertz. Le détecteur est un bolomètre à électron chaud (HEB) en nitrure de niobium (NbN) sur une membrane diélectrique de Si3N4/SiO2 de 1,4 µm d'épaisseur. La membrane est obtenue par une gravure du substrat de silicium. Un miroir focalise le signal THz et une antenne planaire assure le couplage du rayonnement au HEB. Deux blocs mélangeurs ont été développés pendant cette thèse, l'un en configuration axiale et l'autre avec un miroir hors axe. Des antennes planaires de type spirales et double fente ont été conçues pour fonctionner sur la membrane de Si3N4 à des fréquences de 0,6 et 1,4 THz. Une caractérisation FTS réalisée avec une antenne double fente à 0,6 THz a démontré un très bon accord entre la fréquence de résonance mesurée et celle simulée. Une bande passante RF de 40% de la fréquence centrale a été mesurée. Les premières mesures de sensibilité du bloc mélangeur hors axe ont donné des résultats encourageants avec une température de bruit de récepteur de 1300 K à 0,6 THz. La bande passante absolue de la fréquence intermédiaire a été mesurée à 750 MHz. Les travaux à venir sont la montée en fréquence bien au-delà du THz, l'amélioration de la sensibilité du récepteur et le développement de matrice de HEB. Le concept de mélangeur HEB sur membrane pourrait être une solution intéressante pour l'imagerie THz.
15

Imagerie photo-acoustique à détection optique / Photo-acoustic Imaging with Optical Detection

Girardeau, Vadim 16 July 2018 (has links)
Dans le contexte d’une population vieillissante il est primordial de développer des outils de diagnostic cliniques précis, fiables, peu coûteux et faciles à mettre en place. Durant cette thèse j’ai en particulier cherché à réaliser une cartographie dynamique des vaisseaux sanguins dans le but de permettre de détecter à la fois des cancers et des maladies cardiovasculaires, deux des maladies les plus mortelles. Pour avoir un diagnostic efficace on se doit d’imager en profondeur avec une résolution spatiale et temporelle la meilleure possible. Dans le chapitre 0 j’explique les enjeux de l’imagerie médicale sur la micro-vascularisation en analysant les avantages et inconvénients de plusieurs types d’imageries médicales. Dans le chapitre 1 je développe en détail l’imagerie photo-acoustique, qui s’est avérée être la plus appropriée à notre application. Elle a l’avantage d’avoir un contraste optique et une résolution acoustique. J’utilise en particulier la photo-acoustique fréquentielle qui est peu onéreuse et peu encombrante, donc facilement intégrable dans le monde hospitalier par rapport à une imagerie photo-acoustique « classique ». Je valide cette partie sur des résultats expérimentaux in-vivo sur des oreilles de souris. Dans le chapitre 2 j’ai cherché à détecter le signal photo-acoustique de façon optique qui a pour avantage d’être sans contact donc sans souci d’encombrement entre « excitation optique » et « détection acoustique ». Je développe le traitement du signal nécessaire pour détecter une onde acoustique, i.e. des vibrations, à l’aide d’un interféromètre. Puis je présente dans le chapitre 3 un interféromètre particulier développé au laboratoire : le Laser Optical Feedback Imaging (LOFI). Il permet de s’affranchir du bruit du détecteur donc il permet de détecter des vibrations de petites amplitudes même sur des surfaces peu réfléchissantes comme la peau et cela même à faible puissance par respect des normes médicales. Dans le chapitre 4 je valide la détection du signal photo-acoustique avec notre détection optique. Enfin dans le chapitre 5 je montre à travers des simulations une technique d’imagerie innovante plein champ qui permettrait de détecter plus rapidement un signal photo-acoustique riche spectralement. / In the context of an aging population, it is essential to develop clinical diagnostic tools that are accurate, reliable, inexpensive and easy to implement. During this thesis I particularly sought to perform a dynamic mapping of blood vessels in order to detect both cancers and cardiovascular diseases, two of the most deadly diseases. In order to have an effective diagnosis, it is necessary to image in depth with the best possible spatial and temporal resolution. In chapter 0 I explain the challenges of medical imaging on micro-vascularization by analyzing the advantages and disadvantages of several types of medical imaging. In chapter 1 I develop in detail the photo-acoustic imaging, which proved to be the most appropriate for our application. It has the advantage of optical contrast and acoustic resolution. In particular, I use frequency photo-acoustics, which is inexpensive and space-saving, and can therefore be easily integrated in the hospital world compared to "traditional" photo-acoustic imaging. I validate this part on in-vivo experimental results on mouse ears. In chapter 2 I tried to detect the photo-acoustic signal in an optical way which has the advantage of being contactless and therefore without any problem of clutter between "optical excitation" and "acoustic detection". I develop the signal processing necessary to detect an acoustic wave, i.e. vibrations, using an interferometer. Then I present in chapter 3 a particular interferometer developed in the laboratory: the Laser Optical Feedback Imaging (LOFI). This interferometer allows to be limited to photon noise even with a low intensity thus it makes it possible to detect vibrations of small amplitudes even on surfaces with a low reflecting index like the skin in accordance with medical standards. In chapter 4 I validate the detection of the photo-acoustic signal with our optical detection. Finally in chapter 5 I show with simulations an innovative full field imaging technique that would allow faster detection of a spectrally rich photo-acoustic signal.
16

Conception et optimisation de la tête haute fréquence d'un récepteur hétérodyne à 1.2 THz pour l'instrument JUICE-SWI / Design and optimization at the highest frequency of a heterodyne receiver at 1.2 THz for the JUICE-SWI instrument

Moro Melgar, Diego 06 September 2017 (has links)
La conception, fabrication et caractérisation d’un récepteur hétérodyne à 1.2 THz a été effectuée par le Laboratoire d’Etudes du Rayonnement et de la Matière en Astrophysique et Atmosphères (LERMA) et constitue la base de ce rapport de thèse. Les études, analyse et résultats présentés dans ce manuscrit ont été effectués dans le cadre la mission JUpiter ICe moon Explorer (JUICE). JUICE est la première des grandes missions proposées à l’agenda du programme spatial Cosmic Vision 2015-2025 de l’Agence Spatial Européenne (ESA). La mission satellitaire JUICE est consacrée à l’étude du système Jovien. La charge utile du satellite est composée de 10 instruments à l’état-de-l’art et d'une expérience. Le développement du récepteur hétérodyne à 1.2 THz présenté dans cette thèse est dédié à SWI, acronyme anglais de “Submillimeter Wave Instrument", qui, grâce à une résolution spectrale de 107, étudiera à partir de 2030 la structure, la composition et la dynamique des températures de la stratosphère et de la troposphère de Jupiter ainsi que les exosphères et les surfaces des lunes glacées. La partie haute fréquence du récepteur est complètement basée sur la technologie de diodes Schottky planaires sur membrane d'arséniure de galium (GaAs), appelées “Planar Schottky Barrier Diodes” (PSBDs) dans le manuscrit. La réalisation du canal à 1.2 THz de SWI basé sur la technologie Schottky et entièrement développé par le consortium européen, dont fait parti le LERMA, a été le défi le plus significatif rencontré par ce dernier. L'extrême réduction de la taille des anodes des diodes Schottky nécessaire pour monter aux fréquences du THz a été atteinte en collaboration avec le Laboratoire de Photonique et de Nanostructures (LPN) en utilisant la lithographie électronique pour la fabrication de véritables “Monolithic Microwave Integrated Circuits” (MMIC).Une partie importante du ce rapport de thèse et consacrée à l’étude des phénomènes physiques additionnels qui apparaissent quand les dimensions des diodes sont fortement réduites. En particulier, les modifications du comportement résistif et capacitif des diodes Schottky dues à des phénomènes microscopiques bidimensionnels ont été étudiées au moyen d’un simulateur bidimensionnel Monte Carlo (2D-MC), en collaboration avec l’Université de Salamanca, en Espagne.Comme détaillé dans ce manuscrit, la caractérisation précise du comportement capacitif de la diode Schottky est un point critique pour déterminer la plage de fréquences de leur utilisation pour une application donnée. Toute modélisation imprécise de cette propriété de la diode peut entrainer un décalage significatif de la plage de fréquences d’opération d'un circuit THz.Cependant, la modélisation précise des diodes Schottky à ultra-hautes fréquences, n'est qu'une des étapes requises pour réussir à concevoir correctement un circuit THz. L’analyse précise et méticuleuse de l’interaction entre le comportement électromagnétique du chip MMIC et le comportement physique des diodes Schottky a été le but le plus important poursuit dans ce travail doctoral pour le développement du récepteur à 1.2 THz. Cette tâche a été abordée en utilisant les outils commerciaux “High Frequency Simulation/Structure Software” (Ansys-HFSS) et “Keysight Advance Design System” (Keysight-ADS). La combinaison des simulations électromagnétiques des structures tridimensionnelles du chip MMIC (Ansys-HFSS) et les simulations du comportement électrique non-linéaire de la diode Schottky (Keysight-ADS) est la manière actuelle d'aborder la conception de ce type de circuits THz. Le modèle électrique analytique de la diode requis par l’outil ADS a été défini par l'auteur conformément aux résultats précédemment obtenus avec le simulateur physique Monte Carlo. L’implémentation du modèle étendu de la diode Schottky dans cette méthode pour la conception et l'optimisation de chaque étage du récepteur à 1.2THz, est le sujet développé dans ce rapport de thèse. / The design, fabrication and testing of a frequency heterodyne receiver at 1.2 THz has been developed by Laboratoire d’Etudes du Rayonnement et de la Matière en Astrophysique et Atmosphères (LERMA) and it is the foundation of this dissertation. The studies, analysis and results presented in this manuscript have been carried out within the framework of the JUpiter ICe moon Explorer (JUICE) mission. JUICE is one of the proposed missions in the agenda of the European Space Agency (ESA) Cosmic Vision 2015-2025 program. The objective of the JUICE satellite mission is to study the Jovian system, especially the Jupiter atmosphere properties and the surface characteristics of its icy moons. Scientific equipment consisting of ten state-of-the-art instruments and one experiment comprise the payload of this satellite. The development of a 1.2 THz channel is part of the Submillimeter Wave Instrument (SWI) devoted to recovering the spectroscopy data of the Jupiter atmosphere and icy-moons’ surface composition. The scientific principle for this receiver is all-solid-state semiconductor technology based in GaAs Planar Schottky Barrier Diodes (PSBDs). The achievement of a 1.2 THz channel based in PSBDs totally developed by European partners was the major challenge proposed for SWI, with LERMA committed to this assignment. The required ultra-scaling of the Schottky anode size of PSBDs in the attainment of the THz range has been achieved in collaboration with Laboratoire de Photonique et de Nanostructures (LPN) using e-beam photolithography in the fabrication of Monolithic Microwave Integrated Circuits (MMIC). An important part of this dissertation addresses the appearance of additional physical phenomena when ultrascaling solid-state PSBDs. Particularly, the modification of the electrical resistivity and capacitance of SBDs due to two-dimensional phenomena has been studied by means of a physical microscopic Two-Dimensional Monte Carlo (2D-MC) simulator, in collaboration with the University of Salamanca, Salamanca, Spain. As discussed within this manuscript, the accurate characterization of the diode capacitance is one of the critical points when opening a frequency window in the required frequency range of a THz application. A misunderstanding of this modified capacitance during the design of these devices can lead to a considerable offset in the frequency range of the experimental module. However, the accurate modeling of PSBDs in such high frequency applications is only a part of the expertise required for the successful completion of this challenge. The accurate and meticulous analysis of the interrelationship between the electromagnetic behavior of the MMIC chip and the physical behavior of the integrated PSBDs is the main challenge faced in this dissertation for the development of the 1.2 THz receiver. This task has been addressed using the commercial Ansys High Frequency Simulation/Structure Software (Ansys-HFSS) and the Keysight Advance Design System (Keysight-ADS). The combination of the three-dimensional electromagnetic characterization of the chip structure (obtained with HFSS) with the non-linear electrical circuit simulation (carried out by ADS) of diodes is the current methodology for the design of these modules. The analytical electrical model of PSBDs required by ADS software has been defined by this author in agreement with the results obtained with the 2D-MC simulator. The implementation of this approach in the design and optimization of the different stages of the accomplished 1.2 THz receiver is the main subject of this dissertation. The interaction between the physical model of the PSBDs and the electromagnetic modeling of the structure will be discussed within the different chapters of this dissertation. Finally, the mechanical engineering of these applications must be addressed in this discussion.
17

Développement d'un dispositif pompe-sonde hétérodyne : application à l'imagerie en acoustique picoseconde / Setting up of a heterodyne pump-probe bench : application for the imaging with picosecond acoustic waves

Abbas, Allaoua 07 June 2013 (has links)
L' acoustique picoseconde permet l'étude de structures aux dimensions sub-microniques grâce à l'utilisation d'ultrasons dont le contenu spectral peut s' étendre au-delà du THz. La génération et la détection de ces ondes sont rendues possibles par l'association de lasers impulsionnels femtosecondes à dispositifs de type pompe-sonde. Ce manuscrit de thèse décrit la mise en place d'une expérience d' imagerie opto-acoustique avec une résolution spatiale submicronique. L' utilisation combinée d'un échantillonnage optique hétérodyne et de cavités lasers à bas taux de répétition (50 MHz) permet de gagner plusieurs ordres de grandeur sur les temps d'acquisition et de disposer d'une très bonne résolution spectrale. Le manuscrit s'articule autour de trois parties. Dans un premier temps les deux cavités laser aux taux de répértition légèrement différents permettant l'échantillonnage otpique hétérdodyne sont présentées. Puis l'architecture et les performances du système d'asservissement de leur taux de répétion sont décrites. Dans la seconde partie du manuscrit, l'implémentation de cette double cavité dans une expérience pompre-sonde est détaillée et la possibilité de détecter des ondes acoustiques sub-THz avec une résolution de 50 MHz est démontrée. Enfin, dans le dernier chapitre, la puissance de cette expérience pour réaliser de l'imagerie ultra-rapide est illustrée au travers de deux exemples : l'étude d'ondes acoustiques de surface GHz dont la dispersion est induite par la présence d'une couche nanométrique et la détection d'hétérogénéités élastiques submicroniques / Acoustic waves in the Gigahertz or Terahertz frequency range allow the mechanical characterization of submicronic structures. The generation and the detection of these waves can be performed with the use of femtosecond lasers combined with pump-probe setups. This report describes the setting-up of an opto-acoustic imaging experiment with a submicronic spatial resolution. The association of asynchronous optical sampling with the use of low repetition rate femtosecond lasers considerably increases acquisition rates and offers a high spectral resolution, respectively. The first part of this report presents the two laser cavities with slightly different repetition rates in order to perform asynchronous optical sampling. The scheme and the performances of the synchronization stage are described. In the second part, the implementation of this dual-oscillator in a pump-probe experiment is detailed and the ability to detect sub-THz acoustic waves with a 50 MHz-spectral resolution is demonstrated. Finally, in the last chapter, the strong potential of this experiment to perform ultrafast imaging is illustrated through two examples : the measurement of the dispersion of GHz surface acoustic waves due to the presence of a thin film and the imaging and the sizing of submicronic elastic heterogeneities.
18

Détection hétérodyne de molécules d'intérêt atmosphérique à l'aide de lasers à cascade quantique / Heterodyne sensing of atmospheric molecules with Quantum Cascade Laser

Mammez, Marie-Hélène 28 June 2016 (has links)
La détection hétérodyne infrarouge est une technique qui a été développée principalement pour améliorer la détectivité des détecteurs infrarouges, en particulier dans la fenêtre 8-12 μm. Cette technique a longtemps été étroitement associée à l’usage de lasers à gaz. Les domaines d’applications ont été principalement les études astrophysiques et atmosphériques. Peu d’autres applications ont pu être envisagées du fait de la complexité de mise en oeuvre et de l’encombrement de ce type d’instruments. Les progrès récents dans le domaine des lasers à semi-conducteurs (les lasers à cascade quantique - QCL - couvrent une grande partie du spectre infrarouge) permettent d’envisager de nouveaux développements et de nouvelles applications pour la détection hétérodyne infrarouge, par exemple pour la détection et l’identification à distance de molécules d’intérêt atmosphérique telles que les polluants. Les principaux atouts de la détection hétérodyne concernent la sélectivité spectrale et directionnelle de l’instrument. Elle est applicable dans le domaine civil aux molécules d’intérêt atmosphérique telles que l’ozone et le dioxyde de carbone et pour le domaine militaire à la détection d’espèces dangereuses. Un récepteur hétérodyne a été réalisé avec un QCL émettant autour de 10 μm et un corps noir stabilisé en température. Dans ce but, plusieurs systèmes ont été envisagés : un système à base de lentilles, un autre à base de miroirs paraboliques hors axes et un dernier à base de fibres optiques moyen infrarouge. Parallèlement, un héliostat a aussi été développé dans le but de réaliser des mesures atmosphériques. / Infrared heterodyne sensing is a technique which has been developed primarily toimprove the detectivity of infrared detectors, particularly in the 8 − 12 μm window. This technique has long been closely associated with the use of gas lasers. The fields of application were mainly astrophysical and atmospheric studies. Due to the complexity of implementation and the size of this type of instrument, ew other applications could have been envisaged. Recent progress in the field of semiconductor lasers (Quantum Cascade Laser - QCL - cover a large part of the infrared spectrum) enable to consider new developments and new applications for infrared heterodyne sensing, for example for the remote detection and identification of atmospheric molecules, such as pollutants. The main advantages of heterodyne sensing concern spectral and directional selectivity of the instrument. It is applicable in civil sector to atmospheric molecules such as ozone and carbon dioxide, and for the military one to detect hazardous species. A heterodyne receiver has been developed with a QCL emitting at around 10 μm and a temperature stabilized black body. To this end, several systems were considered: a system based on lens, another one based on off-axis parabolic mirrors and a last one based on mid-infrared optical fibers. Meanwhile, a heliostat has also been developed in order to do atmospheric measurements.
19

Méthode d’hétérodynage pour la caractérisation de propriétés thermophysiques par thermographie infrarouge dans une large gamme spatiale et temporelle

Clerjaud, Lilian 23 June 2010 (has links)
De nos jours, l’apport de la miniaturisation a permis d’innombrables progrès scientifiques et techniques : de la microélectronique à la microfluidique et dernièrement les nanotechnologies. Autant de domaines où les enjeux économiques de suivi de qualité ou d’optimisation de production peuvent nécessiter une étape de caractérisation des propriétés intrinsèques des constituants. Parmi ces propriétés, les données thermophysiques permettent notamment de définir la capacité à stocker ou diffuser la chaleur (conductivité, effusivité ou conductivité thermique par exemple). Une manière d’estimer ces propriétés passe par la connaissance du champ de température. Aux échelles microscopiques, seules des mesures de températures sans contact sont plus adaptées. Les travaux de cette thèse rentrent dans cette catégorie en présentant une méthode de caractérisation de propriétés thermophysiques aux échelles microscopiques par le biais de la thermographie infrarouge. En prenant exemple sur les méthodes hétérodynes développées pour la thermoréflectance, nous avons mis au point un stroboscope électronique dédiée à la thermographie infrarouge et permettant de suivre des excitations thermiques locales et périodiques de fréquences caractéristiques de l’ordre du kilohertz avec fréquence d’acquisition caméra de 25 Hz. En couplant cette méthode, que nous qualifierons de méthode d’Hétérodynage, avec une observation microscopique nous pouvons ainsi observer des phénomènes de diffusion longitudinale localisée à la surface d’échantillons diffusifs tels que les métaux et impossible à obtenir avec les applications standard de thermographie infrarouge. A partir de ces données expérimentales, nous montrons sur deux échantillons la manière de remonter à des valeurs de diffusivité dans le plan et dans l'épaisseur. De ces résultats, nous discuterons sur les limitations des estimations notamment dues à l'effet filtre passe bas du temps d'intégration de la caméra prépondérant lorsque l'excitation devient haute fréquence ou à la présence d'une couche émissive (dépôt de spray de peinture noire pour augmenter le contraste thermique) qui peut empêcher la propagation des ondes thermiques de la source au sein du matériau à caractériser dés que la fréquence d'excitation dépasse un seuil dépendant des propriétés thermiques du bicouche étudié. D'une autre manière, nous montrerons que des estimations de diffusivité thermique dans le plan ou transverse peuvent également être possible par une méthode d'hétérodynage en flash périodique. A titre d'applications futures, nous présenterons une première approche académique de modèle de diffusion avec transport sur un disque tournant pour des futures applications d'écoulement en goutes pour la microfluidique, une extension des estimations de diffusivité dans le plan pour obtenir des cartographies en scannant la zone étudiée et des résultats d'hétérodynage en régime périodique transitoire qui pourraient s'assimiler à une réponse de température en échelon. / Nowadays, the contribution of the miniaturization has led to countless advances in science and technology: microelectronics, microfluidics, nanotechnologies... All areas where the economics of quality monitoring and the optimization of production may require a step of characterizing the intrinsic properties of these constituents. Among these porperties, the thermophysical datas can defined the ability to store or distribute the heat (thermal conductivity, effusivity, diffusivity for example). A way to estimate these properties needs the knowledge of the temperature field. At microscale, the measurement temperature without contact is well adapted. The work of this thesis fall into this category by offering a method to characterize the thermophysical properties at microscopic scales by means of infrared thermography. With the help of the heterodyne methods developed for the Thermoreflectance, an electronic stroboscope has been developped. This method is dedied to the infrared thermography and allowing to follow thermal local and periodical excitations with a characteristic frequency around with a frame camera frequency of . By coupling this heterodyne method with microscope lens, it is possible to observe thermal diffusion phenomena longitudinal and transverse localized to the surface of the diffusive sample like metals and impossible to obtain with standard infrared thermography. From experimental data, the values of in-plane or transverse thermal diffusivity are obtained on two samples. Depending of these results, a debate is organized about the limitation of these estimations as the lowpass filter effect of the intregation time of the infrared camera which becomes important with high frequency excitation or the presence of an emissive of thin layer on the surface of the sample (dark spray coating for enhancing the thermal contrast) which can stopped the thermal waves propagation into the layer sample to characterize soon as the excitation frequency exceeds a threshold dependent on the thermal properties of the sample studied. In another way, the estimation of thermal in-plane or transverse diffusivity with an heterodyne method with repeated flash is shown in first results. For future applications, a first academic approach of thermal diffusion model with transport on rotating disk, an extension of the thermal in-plane diffusivity estimation to obtain cartography by scanning the sample area and few heterodyne results in transient periodic regime which are assilimated to a response level were shown.
20

Nanotubes de carbonne ultracourts pour la bioimagerie / Ultrashort carbon nanotubes for bioimaging applications

Faes, Romain 18 February 2014 (has links)
Les travaux de recherche effectués lors de cette thèse portent sur l’obtention de nanotubes de carbone ultracourts et leur biofonctionnalisation pour une utilisation comme biomarqueur proche infrarouge. Des dispersions de nanotubes de carbone en milieux aqueux ont été formulées à l’aide de différents tensioactifs. Un traitement chimique oxydant préalable et/ou l’application d’ultrasons aux nanotubes ont permis de réduire leur longueur de façon significative, la sélection des plus courts étant effectuée par ultracentrifugation en gradient de densité. Les différentes fractions sélectionnées à l’issu de ce processus ont été caractérisées par spectroscopie Raman et spectroscopie d’absorption ainsi que par microscopie à force atomique. Il est ainsi montré la sélection de nanotubes d’une longueur inférieure à 20 nm. Nous montrons également leur fonctionnalisation à l’aide d’anticorps monoclonaux et leur visualisation par imagerie photothermique hétérodyne. Des résultats prometteurs ont été obtenus avec la fixation spécifique de nanotubes de carbone ultracourts sur des cellules. Ces travaux ouvrent de nombreuses perspectives en bioimagerie et en particulier l’étude de la plasticité synaptique au sein de neurones vivants. / This thesis reports the achievement of ultrashort carbon nanotubes and their biofunctionalization for applications as near-infrared biomarker. Dispersions of carbon nanotubes in aqueous media have been formulated with various surfactants. Oxidizing chemical treatments combined with the application of ultrasounds allowed significant shortening of the carbon nanotubes. Sorting and selection of the shortest nanotubes was done by density gradient ultracentrifugation. The different fractions selected at the end of this process have been characterized by Raman spectroscopy, UV-vis absorption spectroscopy and atomic force microscopy. Selection of nanotubes of a length below 20 nm is demonstrated. We also show functionalization by antibodies and the visualization of ultrashort functionalized nanotubes by photothermal heterodyne imaging. Promising results were obtained with the specific binding of ultrashort carbon nanotubes to cells. This work open route towards bioimaging applications and in particular towards the study of the synapsis plasticity within alive neurons.

Page generated in 0.0444 seconds