• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • 3
  • 1
  • 1
  • Tagged with
  • 68
  • 45
  • 23
  • 19
  • 16
  • 14
  • 13
  • 13
  • 11
  • 11
  • 9
  • 9
  • 9
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Obtenção de nanocarreadores magnéticos para hipertermia e liberação controlada de fármacos / Obtain magnetic nanocarriers for hyperthermia and drug Delivery

Freire, Rafael Melo January 2012 (has links)
FREIRE, R. M. Obtenção de nanocarreadores magnéticos para hipertermia e liberação controlada de fármacos. 2012. 113 f. Dissertação (Mestrado em Química) - Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Daniel Eduardo Alencar da Silva (dealencar.silva@gmail.com) on 2014-11-28T18:01:01Z No. of bitstreams: 1 2012_dis_rmfreire.pdf: 3699481 bytes, checksum: 9cca2cc7d0872308e85e24e5e9304d6b (MD5) / Approved for entry into archive by José Jairo Viana de Sousa(jairo@ufc.br) on 2014-12-15T23:41:13Z (GMT) No. of bitstreams: 1 2012_dis_rmfreire.pdf: 3699481 bytes, checksum: 9cca2cc7d0872308e85e24e5e9304d6b (MD5) / Made available in DSpace on 2014-12-15T23:41:13Z (GMT). No. of bitstreams: 1 2012_dis_rmfreire.pdf: 3699481 bytes, checksum: 9cca2cc7d0872308e85e24e5e9304d6b (MD5) Previous issue date: 2012 / In this work, nanoparticles of the M0,5Zn0,5Fe2O4 (M = Ni ou Mn) have been prepared by hydrothermal synthesis in mild conditions without any calcinations process. MFe2O4 (M = Zn, Ni or Mn) nanoparticles were also prepared for comparison. The structural and magnetic properties of the ferrites were investigated by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, Mössbauer spectroscopy, vibrating sample magnetometer (VSM) and Transmission electron microscopy (TEM). XRD analysis showed peaks of the spinel phase for all samples. The average particle size was obtained by XRD, TEM and VSM and values around 10 nm were found for M0,5Zn0,5Fe2O4. TEM images showed particles of cubic morphology. The magnetic parameters observed by Mössbauer and VSM shown superparamagnetic behavior for the samples containing Zn and high saturation magnetization values (~55 emu/g) for Ni0,5Zn0,5Fe2O4. Due to this, it was chosen for formulating the nanocarrier. Thus, it was first modified with oleic acid. The TG and FTIR analysis revealed the presence of oleate molecules on the surface of the nanoparticle. Furthermore, the coating coefficient of the process carried was 3.7 oleate / nm2. A study of piplartine adsorption on the modified nanoparticle (NiZn-AO) was performed and the optimum relationship (NiZn-AO: piplartine) was 1 : 2 (w / w). After the adsorptive process, the system containing NiZn-AO and piplartine was coated with polymeric matrix consisting of F127 and P123 to confer biocompatibility to the system and form the nanocarrier. Hyperthermia tests were performed in nanoparticles and it was observed that a field of 126 Oe leads to heat generation to attain a temperature of 42°C within the range of moderate hyperthermia. Therefore, the fabricated nanocarrier had potential for biomedical applications. / No presente trabalho, nanopartículas de M0,5Zn0,5Fe2O4 (M= Ni ou Mn) foram preparadas por síntese hidrotérmica sob condições brandas sem qualquer procedimento de calcinação. Amostras de composição MFe2O4 (M = Zn, Ni ou Mn) também foram sintetizadas para fins de comparação. As propriedades estruturais e magnéticas das amostras foram investigadas por Difração de Raios-X (DRX), Espectroscopia na Região do Infravermelho com Transformada de Fourier (FTIR), Espectroscopia Raman, Espectroscopia Mössbauer, Magnetômetro de Amostra Vibrante (VSM) e Microscopia Eletrônica de Transmissão (TEM). As análises de DRX exibiram picos característicos da fase de espinélio em todas as amostras sintetizadas. O tamanho médio de partícula foi obtido por DRX, VSM e TEM e apresentou valor em torno de 10 nm para o M0,5Zn0,5Fe2O4. As imagens de TEM exibiram nanopartículas de morfologia cúbica. Os parâmetros magnéticos observados por Mössbauer e VSM mostraram comportamento superparamagnético para todas as amostras contendo Zn, além de altos valores de magnetização de saturação (~55 meu/g) para a amostra Ni0,5Zn0,5Fe2O4. Devido a isto, este núcleo magnético foi escolhido para a formulação do nanocarreador. Desta forma, este foi inicialmente modificado com ácido oléico. As análises de TG e FTIR evidenciaram a presença de moléculas de oleato na superfície da nanopartícula. Além disso, o coeficiente de revestimento do processo realizado foi 3,7 oleato / nm2. Um estudo de adsorção da piplartina na nanopartícula modificada (NiZn-AO) foi realizado e observou-se relação (NiZn-AO : Piplartina) ótima de 1 : 2 (m/m). Após o processo adsortivo, o sistema contendo NiZn-AO e piplartina foi revestido com matriz polimérica constituída de P123 e F127 para conferir biocompatibilidade ao sistema, e formar o nanocarreador. Testes preliminares de hipertermia foram realizados na nanopartícula e observou-se que um campo de 126 Oe conduz a geração de calor para alcançar uma temperatura de 42°C, dentro da faixa de hipertermia moderada. Portanto, o nanocarreador formulado apresenta potencial para aplicações biomédicas.
2

Propuesta de Plan de Negocio para implementación del servicio de Baños de Hipertermia en la empresa SPAVIDA de Lima Norte / Business Plan proposal for the implementation of Hyperthermia Bath services in the SPAVIDA company of Lima Norte

Guillén Castro, Ada Maurina 22 December 2019 (has links)
: / El siguiente proyecto es un trabajo de Tesis desarrollada para Spa Vida con el objetivo de lanzar un nuevo servicio al mercado de nombre “Baños de Hipertermia”, servicio que ayudará a reducir el alto nivel de estrés que tiene el nuevo consumidor. Este lanzamiento traerá beneficios como el incremento de ventas para la empresa, así como la consolidación de la misma en el mercado de Lima y Lima Norte a través de una alta calidad percibida en sus servicios y en el caso del cliente, la reducción de su alto nivel de estrés. En base a lo indicado, Spa Vida busca llegar a todos los consumidores de Lima y Lima Norte de los sectores económicos A, B y C de 25 a 55 años de edad, que tengan conocimiento o que no, acerca de los servicios que ofrece un Spa, pero que por su perfil y estilo de vida son potenciales consumidores, Los estudios de mercado cuantitativos realizados por la propia empresa, demuestran que un 73.3 % de las personas encuestadas No conocen un Spa, mientras que un 26.7 % indicaron que Si conocían, de esta manera el presente trabajo se focalizara en atraer a los posibles clientes y fidelizar la marca a los clientes que se encuentran en cartera. La orientación de la empresa va dirigida hacia el cliente brindándole mayores beneficios y redescubriendo sus necesidades a través de los diferentes insight obtenidos de los resultados de las encuestas propias de la empresa. / The following project is a thesis work developed for Spa Vida with the aim of launching a new service to the market called “Baños de Hypertermia”, a service that will help reduce the high level of stress that the new consumer has. This launch will bring benefits such as the increase in sales for the company, as well as the consolidation of the same in the market of Lima and North Lima through a high quality perceived in its services and in the case of the client, the reduction of its high stress level Based on the above, Spa Vida seeks to reach all consumers in Lima and North Lima of economic sectors A, B and C from 25 to 55 years of age, who have knowledge or not, about the services offered by a Spa, but because of their profile and lifestyle they are potential consumers, Quantitative market studies carried out by the company itself, show that 73.3% of the people surveyed do not know a Spa, while 26.7% indicated that if they knew, in this way the present work will focus on attracting potential customers and Loyalty of the brand to customers in the portfolio. The orientation of the company is directed towards the client, offering greater benefits and rediscovering their needs through the different insithg obtained from the results of the company's own surveys. / Tesis
3

Investigação da hipertermia maligna em Santa Catarina

Batti, Maria Anita Costa Spindola Bez January 2005 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Ciências Médicas / Made available in DSpace on 2013-07-15T23:20:09Z (GMT). No. of bitstreams: 1 228652.pdf: 444495 bytes, checksum: 765ef0c45fd21327988308b6fee2c29e (MD5)
4

Construção de um sistema de atuação magnética por campos em baixa frequência baseado na topologia de bobinas de Helmholtz

Oliveira, Victor Ferreira Antunes de 01 November 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-02-26T20:14:23Z No. of bitstreams: 1 2017_VictorFerreiraAntunesdeOliveira.pdf: 5754880 bytes, checksum: 422b778f72355f9eb9b9669d14da1ae9 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-02-26T21:30:45Z (GMT) No. of bitstreams: 1 2017_VictorFerreiraAntunesdeOliveira.pdf: 5754880 bytes, checksum: 422b778f72355f9eb9b9669d14da1ae9 (MD5) / Made available in DSpace on 2018-02-26T21:30:45Z (GMT). No. of bitstreams: 1 2017_VictorFerreiraAntunesdeOliveira.pdf: 5754880 bytes, checksum: 422b778f72355f9eb9b9669d14da1ae9 (MD5) Previous issue date: 2018-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / No presente trabalho, buscou-se o desenvolvimento e a caracterização eletrônica de um sistema de atuação magnética multidimensional baseado na topologia de bobinas de Helmholtz. O equipamento em questão é capaz de gerar campos magnéticos contínuos, ou modulados em pulsos senoidais, que originam diferentes padrões direcionais e fornecem graus de liberdade tanto translacionais quanto rotacionais para o controle e a ativação de unidades diversas, suscetíveis a campos magnéticos. As bobinas foram dimensionadas para a execução de testes laboratoriais em escala de bancada, fornecendo uma área útil de aporte amostral de até 8 cm, onde a uniformidade do campo produzido deve ser satisfatória e previsível. Na implementação aqui apresentada, a interação mais importante entre os campos magnéticos gerados é a de campo rotatório, que ocorre com a alimentação simultânea dos pares de bobinas perpendiculares em frequências oscilatórias entre 100 Hz e 1000 Hz. No universo de aplicações biomédicas, essas frequências relativamente baixas são conjecturadas como efetivas para aplicações de hipertermia por atrito quando aplicadas sobre as nanoestruturas apropriadas. Portanto, deu-se continuidade à prototipagem das bobinas e à elucidação e adoção de um sistema de amplificação de sinais elétricos, o qual regula a passagem de corrente nas espiras. Para a redução da reatância indutiva indesejável, foi projetado um banco de capacitores variável que auxilia na funcionalidade e na eficiência energética do protótipo. Em seguida, foram realizadas simulações computacionais que modelaram as proporções reais do equipamento para a validação dos padrões circulares dos campos e para a projeção dos valores das forças magnéticas. Por fim, o sistema foi caracterizado quanto à intensidade dos campos gerados e às faixas de frequências operantes em correntes alternadas, nas quais as perdas energéticas são mínimas. Possibilitou-se, assim, o uso do campo magnético de maior intensidade, na faixa de 30mT, para testes preliminares de hipertermia. / A multidimensional magnetic actuation system based on the Helmholtz coil topology was developed and characterized electronically. This equipment generates both continuous magnetic fields and modulated ones in sinusoidal pulses, which provide different directional patterns and multiple degrees of translational and rotational freedom for the control and activation of magnetic units. The coils were designed for bench-scale laboratory tests, providing a sample loading area of up to 8 cm, where the uniformity of the field produced should be satisfactory and predictable. In the implementation phase, it was observed that the most important interaction among the magnetic fields generated is the rotational field, which occurs with the simultaneous activation of both pairs of perpendicular coils in oscillatory frequencies between 100 Hz and 1000 Hz. In the biomedical universe, such low-frequency magnetic fields are thought as potentially effective tools for friction hyperthermia when applied on the appropriate nanostructures. Therefore, the prototyping of the coils and the adoption of an electrical signal amplification system were carried out for the conduction of the necessary electric current. In order to reduce undesirable inductive reactance, a variable capacitor bank was designed which assists the functionality and energy efficiency of the prototype. Then, computational simulations that modeled the actual proportions of the equipment were performed to validate the circular patterns of the magnetic fields and the projection of their values. Finally, the system was characterized in terms of the intensity of the alternating magnetic fields and the bands of frequencies, in which the energy losses were minimal. Thus, the use of the field with highest intensity (in the range of 30mT) was made possible for preliminary tests of hyperthermia.
5

Diseño y desarrollo de sistemas electrónicos de hipertermia y liberación controlada para aplicaciones bioquímicas y farmacológicas

Montes Robles, Roberto 04 May 2018 (has links)
La hipertermia es una técnica de aplicación oncológica comúnmente utilizada en la lucha contra el cáncer que consiste en el calentamiento de los tejidos enfermos a una temperatura entre 40 oC a 48 oC. Su finalidad es la de debilitar y conducir a una muerte natural las células enfermas mediante apoptosis. Desde las primeras aplicaciones de esta técnica, la hipertermia ha progresado sustancialmente, focalizándose cada vez más en la zona tumoral. En dicha evolución, la nanotecnología ha supuesto un gran avance. El reducido tamaño de estos nuevos materiales ha permitido realizar tratamientos mucho más focalizados, pudiendo trabajar incluso a nivel celular. Al contrario que ocurría con las técnicas convencionales, en la hipertermia mediada por nanopartículas, el calor producido mana de dentro de tumor hacia fuera, mejorando sustancialmente la técnica. El presente trabajo se centra en el desarrollo de dos equipos capaces de interactuar sobre nanocompuestos diseñados en laboratorio. Ambos han sido confeccionados para ser utilizados en ensayos in vitro de hipertermia y de liberación controlada de medicamentos. Para ello se ha desarrollado un dispositivo láser, capaz de interaccionar con nanopartículas de oro y un equipo de inducción electromagnética, útil para la excitación de nanopartículas magnéticas. Tras su implementación se han realizado distintas experiencias, destinadas por un lado a verificación de las especificaciones y a la validación en pruebas de campo de los prototipos. A lo largo de los distintos capítulos se explica de forma razonada su elaboración e implementación, tanto de los equipos principales como la de sus accesorios auxiliares. / Hyperthermia is an oncological treatment frequently used that consists of warming ill tissues above 40oC to 48oC. The purpose of this is to weaken and lead the ill cells into a natural death by apoptosis. Hyperthermia has successfully progressed since its first applications focussing more on the tumour area. In this evolution nanotechnology has supposed a huge improvement. The small size of these new materials has allowed to carry out treatments much more focussed. In contrast to conventional techniques, in hyperthermia by nanoparticles, the heat produced flows from inside to outside of the tumour, which substantially improves the technique. This work is focussed on the development of two devices capable to interact with designed nano-composite in laboratory. Both devices have been made to be used in vitro hyperthermia essays and controlled release drug. To get these results a laser device able to interact with gold nanoparticles and an induction electromagnetic device has been developed, useful for exciting magnetic nanoparticles. After its implementation different experiences have been performed, on the one hand to verify the specifications and on the other hand to validate the prototypes in field tests. Through the different chapters, the elaboration and implementation of both the main equipment and its auxiliary accessories are well-reasoned. / La hipertèrmia és una tècnica d'aplicació oncològica comunament utilitzada en la lluita contra el càncer que consisteix en el calfament dels teixits malalts a una temperatura entre 40 °C a 48 °C. La seua finalitat és la de debilitar i conduir a una mort natural les cèl·lules malaltes per mitjà d'apoptosi. Des de les primeres aplicacions d'aquesta tècnica, la hipertèrmia ha progressat substancialment, focalitzant-se cada vegada més en la zona tumoral. En aquesta evolució, la nanotecnologia ha suposat un gran avanç. La reduïda dimensió d'aquests nous materials ha permés realitzar tractaments molt més focalitzats, podent treballar inclús a escala cel·lular. Al contrari que ocorria amb les tècniques convencionals, en la hipertèrmia mitjançada per nanopartícules, la calor produïda brolla de dins de tumor cap a fora, millorant substancialment la tècnica. El present treball se centra en el desenrotllament de dos equips capaços d'interactuar sobre nano compostos dissenyats en laboratori. Ambdós han sigut confeccionats per a ser utilitzats en assajos in vitro d'hipertèrmia i d'alliberament controlada de medicaments. Per això s'ha desenvolupat un dispositiu làser, capaç d'interaccionar amb nanopartícules d'or i un equip d'inducció electromagnètica, útil per a l'excitació de nanopartícules magnètiques. Després de la seua implementació s'han realitzat distintes experiències, destinades per un costat a la verificació de les especificacions i a la validació en proves de camp dels prototips. Al llarg dels distints capítols s'explica de forma raonada la seua elaboració i implementació, tant dels equips principals com la dels seus accessoris auxiliars. / Montes Robles, R. (2018). Diseño y desarrollo de sistemas electrónicos de hipertermia y liberación controlada para aplicaciones bioquímicas y farmacológicas [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/101285
6

Desenvolvimento de gerador de campo magnético alternado para avaliação in vitro de hipertermia em cultura celular

PEDERIVA, Mansueto Bartelega 20 May 2014 (has links)
O corpo humano é formado por milhões de células que se reproduzem por divisão celular e que, em condições normais, é controlada, mas em algumas situações as células perdem a capacidade de controlar seu próprio crescimento, formando o que se conhece como tumor maligno ou câncer. O combate ao câncer pode ser efetuado através de fármacos, cirurgia, radioterapia entre outros. Recentemente surgiu uma técnica experimental: a utilização de nanopartículas magnéticas em um tecido doente e provocar a destruição de suas células através de seu aquecimento acima de 41 °C utilizando-se de equipamentos denominados de geradores de campo magnético alternado. Os equipamentos disponíveis no mercado são todos importados e de alto custo formado por circuitos eletrônicos de difícil ajuste. A fim de nacionalizar e baixar o custo desta tecnologia, foi objetivo deste trabalho a construção de um gerador de campo magnético alternado para avaliação in vitro de hipertermia em cultura celular. Para seu desenvolvimento foi necessário estudar o funcionamento de equipamentos similares importados. Em seguida, foi constatada a existência de um aparelho de produção nacional e de custo acessível para uso industrial com a finalidade de aquecer metais, porém com o mesmo princípio de funcionamento destes equipamentos importados. Os circuitos foram construídos e modificados para o aquecimento de nanopartículas magnéticas. O protótipo foi construído e avaliado comparando-o com um equipamento importado destinado ao aquecimento de nanopartículas magnéticas. Foi comprovado que o protótipo aquece, acima de 41 °C, tanto a magnetita em tamanho micrométrico como a magnetita dispersa em água e com tamanho nanométrico. Também foi observado que a intensidade de campo magnético alternado e sua frequência provocam alteração nos perfis de aquecimento das nanopartículas magnéticas diluídas em água (ferrofluidos) a medida de sua proporção em comparação com a massa de água presente. O protótipo atingiu o valor de aquecimento para hipertermia demonstrando viabilidade técnica para implantação do piloto como gerador de campo magnético alternado nacional para estudo do uso de nanopartículas magnéticas no tratamento de câncer via hipertermia ou liberação controlada de fármacos. / The human body is made of millions of cells that reproduce through cell division and that, under normal conditions, is controlled, but in some situations the cells lose the capacity to control their own growth, forming what is known as a malignant tumor or cancer. There are several ways to treat cancer such as drugs, surgery, radiotherapy among others. Lately emerged a technique based on magnetic nanoparticles used in association to the hyperthermia. The new technique consists in insert magnetic nanoparticles in the diseased tissue and cause the destruction of cancer cells through its heating above 41 °C using an alternating magnetic field generators. Nowadays, only imported equipment is in the market at a high cost and made by complex electronic circuits. In order to nationalize and decrease the cost of this technology, the aim of this work was the construction of an alternating magnetic field generator for evaluation of hyperthermia in vitro in cell culture. It was necessary to evaluate how similar imported equipment works. As a started point model, a national industrial equipment used for melting metals was used. The circuits were built and modified for heating magnetic nanoparticles. The prototype was built and compared with the imported equipment used to heat magnetic nanoparticles. It was observed that the prototype heats the magnetite particles even in micrometric or nanometric sizes above 41°C. It was also observed a relation between the intensity of the alternating magnetic field and its frequency with the amount of water present as dispersion media for magnetic particles. The prototype was able to heat magnetic nanoparticles achieving a value of heating satisfactory to hyperthermia treatment. Thus, the feasibility to construct a pilot as national alternating magnetic field generator was proven.
7

Modelagem computacional da biotransferência de calor no tratamento por hipertemia em tumores de duodeno através do método dos volumes finitos em malhas não-estruturada

Simone Cardoso Guimarães, Carla January 2003 (has links)
Made available in DSpace on 2014-06-12T17:39:28Z (GMT). No. of bitstreams: 2 arquivo7336_1.pdf: 1559868 bytes, checksum: 343cbe4a79bc3bb42a57042b8cc84f9f (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / Diversos procedimentos médicos, inclusive aqueles cirúrgicos que utilizam laser, têm como principal fator limitante o aumento de temperatura no tecido vivo fato que pode causar danos irreversíveis ao mesmo, chegando até à sua evaporação. A hipertermia pode ser o processo terapêutico em si (tratamento de tumores com laser, com radiofreqüência e ablação) ou decorrente dele (cirurgias oftalmológicas refrativas com uso de laser). Ferramentas numéricas e computacionais, utilizadas na engenharia, são cada dia mais usadas na simulação de tais procedimentos com o intuito de calcular o campo de temperaturas, tendo como propósito guiar o médico mais precisamente antes de uma intervenção. Algumas aplicações podem ser simuladas com o uso de coordenadas cilíndricas ou esféricas. Em outras, o uso de malhas não-estruturadas é mais adequado devido à presença maciça de geometrias irregulares no corpo humano. Tumores não-operáveis podem ser irradiados com fontes de laser por via endoscópica. Sua função é causar uma elevação de temperatura local a fim de destruir as células cancerígenas, sem, no entanto, causar dano térmico à região sadia circunvizinha. A precisão desta análise está ligada à utilização de métodos numéricos adequados. O presente trabalho visa o desenvolvimento de uma ferramenta computacional através da utilização do método dos volumes finitos (MVF) para solucionar a equação da biotransferência de calor em malhas bidimensionais triangulares não-estruturadas. Serão feitas descrições: do modelo físico-matemático pertinente; da função dano; da técnica para obtenção do domínio geométrico de interesse; das propriedades termofísicas dos tecidos envolvidos na questão; bem como da escolha da fonte de laser mais adequada à utilização no procedimento a ser simulado. Em seguida será descrita a formulação do método dos volumes finitos com estrutura de dados por arestas, e apresentada a aproximação usada na solução das integrais envolvidas no modelo. Descreve-se então todo o ciclo envolvido na modelagem e implementação computacional da metodologia adotada, que compreende as seguintes etapas: captura e digitalização da imagem; modelagem geométrica e geração da malha discreta; préprocessamento dos dados; programa de análise via Método dos Volumes Finitos (MVF); pósprocessamento e visualização dos resultados. Alguns exemplos usados para validação do programa de análise são apresentados. Finalmente, apresenta-se o problema analisado, onde um tumor de duodeno de 2cm de diâmetro foi aquecido, através de uma sonda de laser Nd:YAG, em três pontos diferentes, durante um tempo total de 120s, divididos em dois ciclos de 60s. As temperaturas nos pontos mais críticos atingiram valores da ordem de 135°C, com o dano alcançando valores da ordem de 1018. Porém a interface entre o tumor e o tecido sadio, não apresentou dano térmico, sob as condições supracitadas
8

Estudo do comportamento físico da hidroxiapatita dopada com ferro / Study of physical behavior of hydroxyapatite calcined with iron

Pinto Filho, Francisco 09 April 2008 (has links)
PINTO FILHO, F. Estudo do comportamento físico da hidroxiapatita dopada com ferro. 2008. 63 f. Dissertação (Mestrado em Ciência de Materiais) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2008. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-03-31T17:11:18Z No. of bitstreams: 1 2008_dis_fpintofilho.pdf: 2968474 bytes, checksum: e64e32d11fd90b5635c94a8a1189b9ac (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-04-01T19:36:55Z (GMT) No. of bitstreams: 1 2008_dis_fpintofilho.pdf: 2968474 bytes, checksum: e64e32d11fd90b5635c94a8a1189b9ac (MD5) / Made available in DSpace on 2016-04-01T19:36:55Z (GMT). No. of bitstreams: 1 2008_dis_fpintofilho.pdf: 2968474 bytes, checksum: e64e32d11fd90b5635c94a8a1189b9ac (MD5) Previous issue date: 2008-04-09 / The bioceramic called hydroxyapatite (HA) is a biocompatible material which can be an important tool in hyperthermia applications for the treatment of bony cancer. In this work the effect of the addition of Fe ions in the structure of the HA was investigated with the objective of obtaining a magnetic bioceramic to be used in the hyperthermic treatment against the cancer. The samples were prepared by the ceramic method and characterized by the X-ray diffraction (XRD), infrared spectroscopy (FTIR), Vickers hardness, electric properties (constant and loss dielectric) and scanning electronic microscopy (SEM). The presence of the phase Ca2Fe2O5 was verified by X-ray diffraction analysis, showing a structure Brownmillerite. The improvement of the mechanical and electric properties was verified with the increase of the sintering temperature. It was observed that the increase of the Fe addition and the sintering temperature caused morphologic changes in the grains. / A biocerâmica de hidroxiapatita (HA) é um material biocompatível no corpo humano e pode ser uma importante ferramenta em aplicações de hipertermia para o tratamento no câncer ósseo. Neste trabalho investigou-se o efeito da adição de íons de ferro na estrutura da HA com o objetivo de obter uma biocerâmica que venha ser utilizado no tratamento hipertérmico contra o câncer. As amostras foram preparadas pelo método cerâmico e caracterizadas pela difração de raios-X, espectroscopia do infravermelho (FTIR), microdureza Vickers, medidas elétricas (constante e perda dielétrica) e microscopia eletrônica de varredura (MEV). Através da difração de raios-X verificou-se a presença da fase Ca2Fe2O5 que apresenta uma estrutura denominada Brownmillerite. Verificou-se melhoria das propriedades mecânicas e elétricas com o aumento da temperatura de sinterização. Observou-se que o aumento da concentração de ferro e da temperatura de sinterização ocasionaram mudanças morfológicas nos grãos.
9

Desenvolvimento e caracterização de nanopartículas de Óxido de Ferro para o tratamento de leishmaniose cutânea via hipertermia por ondas curtas

Mendonça, Ayrles Silva Gonçalves Barbosa, 92-98116-8814 30 March 2017 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-07-31T13:23:03Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-07-31T13:23:17Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-07-31T13:23:38Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) / Made available in DSpace on 2017-07-31T13:23:38Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) Previous issue date: 2017-03-30 / Leishmaniasis is a disease that affects around 12 million people worldwide, being prevalent in 5 continents and considered endemic in 98 countries. The cutaneous form is the most common and can be caused by approximately 20 species. In Brazil, the antimony drug is used as the first choice in the treatment of leishmaniasis. After intravenous administration, it is rapidly absorbed and almost 90% of the antimony is excreted within the first 48 hours by the kidneys. As a consequence, the administration of high doses is indispensable, which generates many side effects, including cardiorespiratory and renal alterations. In this sense, the general objective of this work was the development of pure maghemite nanoparticles and coated with glucuronic and fructose acid, shortwave, aiming to generate an innovative treatment protocol, via hyperthermia for the treatment of cutaneous leishmaniasis lesions. In addition to the synthesis of nanoparticles, characterization tests were performed, including field emission gun microscopy (FEG); X-ray diffraction; Fourier-transformed infrared spectroscopy (FTIR); Möusbauer spectroscopy and magnetic measurements (ZFC). Short-wave parameter definition tests and in vitro cell viability assays, with and without the use of short waves, were also performed. Results: The results of the FEG revealed a well ordered structure of nanoparticles, with an average diameter of 60nm. X-ray diffraction data, together with Möusbauer, indicated the oxidation state and crystalline phase of the iron oxide compatible with a pure sample of maghemite. The FTIR measurements indicated adsorption of the binders to the nanoparticles, especially when coated with glucuronic acid. The magnetization measurements by ZFC indicated, in all samples, magnetic properties compatible with ferromagnetic regime and saturation magnetization between 56 and 59 emu /g, indicating that these materials when exposed to an alternating electromagnetic field will allow hyperthermia. Finally, the in vitro assays indicated a real leishmanicidal effect when the pure or coated nanoparticles were exposed to the alternating magnetic field of the short waves for 30 minutes, which generated hyperthermia and consequent death of the pathogen. In view of the above, it is possible to conclude that the application of the proposed leishmanicide method indicated a high potential of use for the treatment of cutaneous leishmaniasis lesions / A leishmaniose é uma patologia que afeta cerca de 12 milhões de pessoas em todo mundo, sendo prevalente em 5 continentes e considerada endêmica em 98 países. A forma cutânea é a mais comum e pode ser causada por aproximadamente 20 espécies. No Brasil, o medicamento à base de antimônio é utilizado como primeira escolha na terapêutica da leishmaniose. Após administração endovenosa, ele é rapidamente absorvido e praticamente 90% do antimônio é excretado nas primeiras 48h pelos rins. Em conseqüência, faz-se indispensável a administração de doses elevadas, o que gera muitos efeitos colaterais, incluindo alterações cardiorrespiratórias e renais. Nesse sentido, o objetivo geral do presente trabalho constituiu-se como o desenvolvimento e caracterização de nanopartículas de maghemita puras e revestidas com ácido glicurônico e frutose, atrelado a aplicação de ondas curtas, visando a geração de um protocolo de tratamento inovador, via hipertermia, para o tratamento de lesões de leishmaniose cutânea. Para tanto, foram realizados, além da síntese das nanopartículas, ensaios de caracterização, que incluem, entre outros, microscopia de varredura, via FEG; difração de Raio-X; espectroscopia na região do infravermelho (FTIR); espectroscopia de Möusbauer e medidas magnéticas (ZFC). Ensaios de definição de parâmetro de ondas-curtas e ensaios de viabilidade celular in vitro, com e sem o uso de ondas curtas, também foram realizados. Os resultados do FEG revelaram uma estrutura bem ordenada de nanopartículas, com diâmetro médio na ordem de 60nm. Os dados de difração de raio-X, juntamente com Möusbauer, indicaram o estado de oxidação e fase cristalina do oxido de ferro compatível com uma amostra pura de maghemita. As medidas do FTIR indicaram adsorção dos ligantes às nanopartículas, sobretudo quando revestidas com ácido glicurônico. As medidas de magnetização por ZFC indicaram, em todas as amostras, propriedades magnéticas compatíveis com regime ferromagnético e magnetização de saturação entre 56 e 59 emu/g, indicando que esses materiais quando expostos à um campo eletromagnético alternado permitirão a hipertermia. Por fim, os ensaios in vitro indicaram um real efeito leishmanicida quando as nanopartículas puras ou revestidas foram expostas ao campo magnético alternado do ondas-curtas por 30 minutos, o que gerou hipertermia e consequente morte do patógeno. Diante do exposto, é possível concluir que a aplicação do método leishmanicida proposto indicou um alto potencial de utilização para o tratamento de lesões de leishmaniose cutânea via hipertermia por ondas-curtas com nanopartículas de maghemita.
10

Síntese e caracterização de LaCoO3 em bulk com falhas e de nanopartículas de La0,75Sr0,25MnO3 com estudos de aquecimento

Pimentel, Bruno Martins 04 May 2017 (has links)
Submitted by Biblioteca do Instituto de Física (bif@ndc.uff.br) on 2017-05-04T18:37:39Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertação Bruno Martins Pimentel.pdf: 23833817 bytes, checksum: 94eecaa5577cf1389dbe6937db8cdbc8 (MD5) / Made available in DSpace on 2017-05-04T18:37:39Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertação Bruno Martins Pimentel.pdf: 23833817 bytes, checksum: 94eecaa5577cf1389dbe6937db8cdbc8 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Óxidos de metal de transição tem propriedades físicas fascinantes que são governadas por interações entre os graus de liberdade de cargas, spins, rede e orbital. Especi camente as perovskitas de LaCoO3 tem atraído muita atenção principalmente devido ao grau de liberdade de spin, onde transições de spin induzidos pela temperatura levam a diferentes comportamentos magnéticos. Já as perovskitas de La0,75Sr0,25MnO3, como são manganitas, tem muitos estudos a respeito de agnetorresistencia colossal e, nas últimas décadas, este material vem sendo proposto para tratamento de câncer via hipertermia magnética. Com isso, o presente trabalho foi separado em dois trabalho, onde a partir do método sol-gel, série de LaCoO3 e nanopartículas de La0:75Sr0:25MnO3 foram sintetizadas para estudos de seus comportamentos. O primeiro trabalho consiste em compostos bulk com falhas estruturais de LaCoO3 . Estes foram sintetizados para a tentativa de simulação das nanopartículas, pois estas possuem um defeito de superfície, que é a provavel causa do ferromagnetismo nelas, o que não é observado na forma bulk. Para isto, foram sintetizados os compostos La1x xCoO3, onde x=0.04, 0.08 e 0.12 e representa a falha. A partir disso, caracterizações por difração de raios-X e medidas magnéticas de MxH e MxT foram feitos. Discussão acerca do comportamento magnético, a partir do peff , p e constante de Curie dos compostos com falha foram realizadas. Foi observado comportamento semelhante dos compostos com falhas no bulk com as nanopartículas de LaCoO3, revelando que o comportamento magnético das nanopartículas provém de falhas no composto. Um modelo básico de 2 sub-redes dispostas anti-paralelamente compostas de Co4+ (devido a vacância do lantânio) e Co3+ foi proposto para este problema. O segundo trabalho consiste em avaliar o comportamento de La0:75Sr0:25MnO3 nanoparticulados quando submetidos à um campo magnético externo AC, para possível aplicação em hipertermia magnética, devido à mecanismos de aquecimento. Para isso, nanopartículas foram sintetizadas e, a partir da difração de raios-X, foi constatado o tamanho médio do cristalito de 43.2 nm. A principal propriedade para um material candidato à aplicação em hipertermia magnética é a sua capacidade em controlar a temperatura, com isso, aliado ao controle da temperatura de Curie, medidas de aquecimento foram feitas, constatando que a temperatura para de aquecer na temperatura de bloqueio, o que permite o controle da temperatura máxima. A estabilização da temperatura em função do campo magnético revelou que, em 100 Oe, a temperatura é aplicável para propósitos médicos. / Transition metal oxides has fascinating properties that are ruled by interaction between charges, spin, lattice and orbital degrees of freedom. Speci cally the LaCoO3 perovskites have attracted much attention mainly due to the spin degree of freedom, where spin transition induced by temperature lead to di erent magnetic behaviors. The La0,75Sr0,25MnO3 perovskite, such as manganites, has many studies on colossal magnetoresistance and, in recent decades, this material has been proposed for cancer treatment throught magnetic hyperthermia. So, the present work was separated in two, where from the sol-gel method, LaCoO3 series and La0,75Sr0,25MnO3 nanoparticles were synthesized to study their behaviors. The rst work consist in bulk compounds with structural failures of LaCoO3. These were synthesized to try simulate nanoparticles, because they have a surface defect, which is probably the cause of their ferromagnetism, which is not observed in bulk form. For this, the compounds La1x xCoO3, where x=0.04, 0.08 e 0.12 and represents the failures were synthesized. From this, characterizations by x-ray di raction and magnetic measurements of MxH and MxT were made. Discussion of the magnetic behavior, from peff , p and Curie constant of the compounds with failure were performed. Similar behavior of bulk compounds with failure with the nanoparticles were observed, revealing that the magnetic behavior of the nanoparticles rise from failures on compounds. A basic 2 su-lattice model arranged anti-parallel composed of Co4+ (due the lanthanum vacancy) and Co3+ was proposed for this problem. The second work consist in evaluating the behavior of La0,75Sr0,25MnO3 nanoparticles when submited to an external magnetic eld AC , for possible maagnetic hyperthermia application, due to heating mecanisms. For this, nanoparticles were synthesized and, from x-ray di raction, the average size of 43.2 nm were found. The main property for a material candidate for application in magnetic hyperthermia is its ability of self-control of temperature, thus, allied to Curie temperature control, heating measurements were made, noting that the temperature stops to rise at blocking temperature, which allows maximum temperature control. The stabilization temperature as a function of magnetic eld revealed that, at 100 Oe, the temperature is applicable for medicinal purposes.

Page generated in 0.023 seconds