• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 168
  • 7
  • 7
  • 7
  • 7
  • 6
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 172
  • 172
  • 128
  • 122
  • 52
  • 36
  • 32
  • 26
  • 23
  • 23
  • 22
  • 21
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação da resistência à corrosão de titânio comercialmente puro submetido à desinfecção química e polarização em salivas artificiais com diferentes pHs / Evaluation of corrosion resistance of commercially pure titanium submitted to chemical disinfection and polarization in artificialsalivas with different pHs

Lariça Barbosa Raimundo 26 August 2010 (has links)
O objetivo desse estudo foi avaliar a ação de hipoclorito de sódio e ácido peracético na resistência à corrosão de titânio comercialmente puro, grau 4, (Ticp-4) em salivas artificiais, ácida e neutra, com diferentes períodos de imersão, por meio de ensaio de polarização potenciodinâmica anódica, microscopia eletrônica de varredura e espectrometria dispersiva de raios-X. Corpos-de-prova cilíndricos (5 mm x 5 mm) de Ticp-4 foram envolvidos com fio de cobre e fita isolante, este conjunto foi incluído em tubos de PVC (25 mm x 15 mm) e preenchidos com resina poliéster quimicamente ativada, após a polimerização da resina esses eletrodos de trabalho que foram polidos mecanicamente com lixas, feltros e pastas. Os 54 eletrodos de trabalho foram divididos em nove grupos (n=6) referentes às soluções e períodos de imersão: água destilada (controle), hipoclorito de sódio 1% (10 e 40 minutos), ácido peracético 0,2% (10, 30, 40 e 120 minutos) e ácido peracético 2% (30 e 120 minutos). Após serem imersos nas soluções, foram divididos em 2 subgrupos (n=3), pois os ensaios de polarização anódica foram realizados em triplicatas e utilizados dois eletrólitos, salivas artificiais pH 4,8 e pH 6,8. No ensaio de polarização anódica foi utilizada uma célula eletroquímica constituída por um eletrodo de referência do tipo calomelano saturado (ECS), um contra-eletrodo de platina e o eletrodo de trabalho constituído pelas amostras de Ticp-4, com taxa de varredura de 1 mV/s, partindo-se do potencial de corrosão (Ecorr) até 800 mVECS. Os dados do potencial de corrosão (Ecorr) e corrente de passivação (Ipass) obtidos das curvas de polarização foram analisados estatisticamente pelo teste t Student. Na comparação entre salivas ácida e neutra os valores de Ecorr e Ipass em todas soluções desinfetantes e períodos propostos não apresentaram diferença estatísitica. A comparação dos valores de Ecorr e Ipass entre água destilada (controle) e soluções desinfetantes em saliva ácida também não mostrou diferença, porém em saliva neutra houve diferença entre os valores de Ipass entre água destilada e hipoclorito de sódio 1% por 40 minutos e entre os valores de Ecorr entre água destilada e ácido peracético 2% por 120 minutos. Entre períodos de imersão, em saliva ácida, houve diferença entre os valores de Ipass do hipoclorito de sódio 1% 10 e 40 minutos e entre os valores de Ecorr do ácido peracético 0,2%. A microscopia eletrônica de varredura associada à energia dispersiva por Raio-X não mostrou diferença entre água destilada e as diferentes soluções desinfetantes frente as salivas ácida e neutra. Conclui-se que as curvas de polarização anódica foram similares em todos os ensaios, apesar das diferenças estatísticas salientadas para Ipass e Ecorr, não ocorreu corrosão superficial em quaisquer amostras após desinfecção e polarização em salivas ácida e neutra. A análise por microscopia eletrônica de varredura associada à espectrometria por dissolução de raios-X não revelaram alterações superficiais nas amostras de titânio comercialmente puro. / This study aimed to assess the corrosion resistance in a grade-4 commercially pure titanium (CP Ti-4) under action of sodium hypochlorite or peracetic acid, during different immersion periods, in acid or neutral artificial saliva for anodic potentiodynamic polarization test. Scanning Electron Microscopy (SEM) was used in conjunction with Energy Dispersive X-Ray Spectroscopy (EDS). This study aimed to assess the corrosion resistance in a grade-4 commercially pure titanium (CP Ti-4) under action of sodium hypochlorite or peracetic acid, during different immersion periods, in acid or neutral artificial saliva for anodic potentiodynamic polarization test. Scanning Electron Microscopy (SEM) was used in conjunction with Energy Dispersive X-Ray Spectroscopy (EDS). Cylindrical CP Ti-4 specimens (5 mm x 5 mm) were involved with copper wire and electrical tape, this set was enclosed in PVC pipe (25 mm x 15 mm) and filled with chemically activated polyester resin to obtain the fifty-four working electrodes which were, then, mechanically polished with sandpaper, felt and polishing paste. The 54 working electrodes were divided into nine groups (n = 6) for solutions and immersion periods: distilled water (control), sodium hypochlorite 1% (10 and 40 minutes), peracetic acid 0.2% ( 10, 30, 40 and 120 minutes) and 2% peracetic acid (30 and 120 minutes). After being immersed in the solutions, they were divided into two subgroups (n = 3), because the anodic polarization tests were performed in triplicate and two electrolytes were used: artificial saliva pH 4.8 and pH 6.8. A saturated calomel electrode (SCE) was used as a reference electrochemical electrode for the anodic polarization test with a platinum counter electrode and a working electrode consisting of CP Ti-4 samples with a 1 mV/s scan rate , starting from the corrosion potential (Ecorr) to 800 mVECS. Data for corrosion potential (Ecorr) and for passive current (Ipass) obtatined from the polarization curves were statistically analyzed by Students t-test. When comparing the Ecorr and Ipass values for acid and neutral saliva and disinfectant solutions during all the periods the statistics presented no difference. The comparison of Ecorr and Ipass values between distilled water (control) and disinfecting solutions in acid saliva also showed no difference, but in neutral saliva there was difference for the values of Ipass between distilled water and 1% sodium hypochlorite for 40 minutes and for the values of Ecorr between distilled water and 2% peracetic acid for 120 minutes. When comparing immersion periods, the acid saliva showed different Ipass values for 1% sodium hypochlorite in 10 and 40 minutes and between the Ecorr values for 0.2% peracetic acid. The scanning electron microscopy associated with Energy Dispersive X-Ray Spectroscopy showed no difference between distilled water and the different disinfectant solutions when in acid or neutral saliva. It is concluded that the polarization anodic curves for both acid and neutral saliva were similar in all trials, despite the statistical differences highlighted for Ipass and Ecorr, surface corrosion did not occur in any samples after disinfection and polarization in acidic and neutral saliva. Analysis by Scanning Electron Microscopy associated with Energy Dispersive X-Ray Spectroscopy revealed no surface changes in the commercially pure titanium samples studied.
112

Degradação de interfaces adesivas formadas após desmineralização e desproteinização da dentina / Long-term bond strengths of adhesive systems applied to etched and deproteinized dentin

Gómez, Ninoshka Uceda 07 December 2007 (has links)
O objetivo deste estudo foi avaliar a resistência de união de 2 sistemas adesivos convencionais de dois passos (Single Bond-SB, 3MESPE e One Step-OS, Bisco) aplicados à dentina desmineralizada [SH] e desmineralizada e desproteinizada com NaOCl a 10% [CH], tanto no tempo imediato [IM] como após 12 meses de imersão em água [12M]. Realizou-se também a observação da morfologia das interfaces de união entre os sistemas adesivos e a superfície de dentina em Microscópio Eletrônico de Varredura (MEV) para cada grupo experimental. O esmalte oclusal de 20 molares permanentes hígidos foi removido para expor as superfícies planas de dentina, que foram condicionadas com H3PO4 a 37%, lavadas e secas (grupos SH). Para os grupos CH após o condicionamento ácido foi aplicado hipoclorito de sódio a 10% durante 60 s, seguido de lavagem por 15 s. Os sistemas adesivos foram aplicados de acordo com as recomendações dos fabricantes. Coroas de resina composta (Z-250, 3MESPE) foram construídas de forma incremental (600 mW/cm² por 40 s). Após armazenagem em água por 24h a 37°C, os espécimes foram secionados para obter corpos-de-prova na forma de palitos (0,8mm²), que foram testados sob tração (0,5 mm/min) no tempo imediato [IM] ou após 12 meses de armazenamento em água. Dois dentes de cada grupo foram observados em MEV nos dois períodos de tempo. Os dados de resistência de união foram submetidos à uma análise de variância de três fatores e teste de Tukey para contraste das médias (p = 0,05). As interações duplas e triplas não foram estatisticamente significantes (p> 0,05), assim como o fator principal Tratamento de superfície (p = 0,05). Somente os fatores principais Adesivo e Tempo de armazenagem foram significantes (p = 0,04 e p = 0,03, respectivamente). O adesivo SB (43,3 ± 9,1 MPa) apresentou altos valores de resistência de união quando comparado com o OS (33,3 ± 11,6 MPa). A resistência de união do grupo IM (42,5 ± 8,7) foi estatisticamente superior à grupo 12M (33,3 ± 11,8). / The aim of this study was to evaluate the early and 12-month bond strengths of two adhesive systems (Single Bond-SB, 3MESPE and One Step-OS, Bisco) applied to demineralized dentin (WH) and demineralized/NaOCl-treated dentin (H). The adhesive interfaces were also micromorphologically evaluated by Scanning Electron Microscopy (SEM). Twenty flat dentin surfaces were exposed. They were etched, rinsed and slightly dried. For the H groups, a solution of 10% NaOCl was applied for 60s, rinsed (15 s) and slightly dried. The adhesives were applied according to the manufacturer\'s instructions and composite resin crowns were incrementally constructed. After 24 h (water-37°C), the sample was sectioned in order to obtain resin-dentin sticks (0.8 mm²). The specimens were tested in tension (0.5 mm/min) immediately (IM) or after 12 months of water storage (12M). Two teeth from each experimental group were restored as described previously and evaluated under SEM, under the two storage periods. The data (MPa) were subjected to three-way ANOVA and Tukey\'s test (? = 0.05). No significant effects for the triple and double interactions (p > 0.05) as well as for the main factor Surface treatment were observed (p > 0.05). Only the main factors Adhesive and Storage time were statistically significant (p = 0.004 and p = 0.003, respectively). The adhesive SB (42.3 ± 9.1) showed higher bond strengths than OS (33.6 ± 11.6). The mean bond strength for IM-group (42.5 ± 8.7) was statistically superior to 12M (33.3 ± 11.8). The use of 10% sodium hypochlorite, after acid etching, did not improve the immediate and the long term resin-dentin bond strengths for acetone and water/alcohol based adhesive systems.
113

Análise "in vitro" da resistência adesiva de sistemas adesivos autocondicionantes com o substrato dentinário após a desproteinização dentinária

Antury, José David Ruan 18 November 2005 (has links)
Made available in DSpace on 2017-07-24T19:22:14Z (GMT). No. of bitstreams: 1 Jose David.pdf: 1396926 bytes, checksum: 7d3efdcd4df11b4c6bee44febd2ff0bb (MD5) Previous issue date: 2005-11-18 / The purpose of this study was to evaluate “in vitro” the bond strength of the self etch adhesive systems One Coat SE Bond, Self Etch Bond, and XENO®III with the dentin substrate, by means of the microtensile bond strength test, after dentin deproteinization. The conventional adhesive system Adper Single Bond™/3M™-ESPE™ was used as group control. Thirty five human integral third molars were chosen. Theirs occlusal surfaces were cut 3mm±1mm. The dentin surfaces polished with silicon carbide sandpaper of granulation 600 during 1min, in a Politriz. Each group (n=5) received its respective adhesive systems, GI: controle (hybrid layer); GII, GIV and GVI: self etch adhesive systems (reaction-integration); GIII, GV and GVII: self etch adhesive systems (deproteinization). The teeth were restored with resin composite Filtek Z-250 3M™/ESPE™. 24 hours after, the teeth were sectioned using a diamond saw mounted in a Labcut 1010 machine, to get perpendicular sections to the bonding interface with a cross-sectional area to the approximately 0,7 mm2. Were selected 3 specimens per group. Which were prepared and analyzed through the scanning electronic microscope of camp emission and the “confocal laser scanning microscope”, the remaining specimens were submitted to microtensile bond strength in an universal testing machine, at a crosshead speed of 1 mm/min. the mode of fracture was observed using a optic microscope. For each one of the self etching adhesive systems a viscosity test was accomplished. The values of bond strength were submitted to statistical analysis using the Kruskal-Wallis test. The results had shown that the self etch adhesive system XENO®III, after the deproteinization with NaOCl 5,2% (43,60±11,44 MPa) presented the higher values of bond strength. The lowest values were observed in the self etch adhesive system One Coat SE Bond with and without deproteinization (27,50±8,75 MPa) and (27,07±7,27 MPa) respectively. The Self Etch Bond with NaOCl 5,2% demonstrated higher values of bond strength. The microscopy analyses allowed to observed the differences between the adhesive interfaces gotten (hybrid layer, reaction-integration, deproteinization). By this study was possible demonstrated that the dentin deproteinization through the application of NaOCl 5,2%, not influenced on the bond strength of the self etch adhesive systems One Coat SE Bond and XENO®III. In the self etch adhesive system Self Etch Bond with NaOCl the bond strength increased significantly. / O objetivo deste trabalho foi avaliar “in vitro” a resistência adesiva dos sistemas adesivos autocondicionantes One Coat SE Bond, Self Etch Bond, e o XENO®III com o substrato dentinário, por meio do teste de microtração, após a desproteinização dentinária. O sistema adesivo convencional Adper Single Bond™/3M™-ESPE™ foi utilizado como grupo controle. Foram selecionados 35 terceiros molares humanos íntegros. As superfícies oclusais foram cortadas 3mm±1mm. As superfícies de dentina polidas com lixas de carbureto de silício de granulação 600 por 1 min., numa Politriz. Cada grupo (n=5) recebeu os respectivos sistemas adesivos GI: controle (camada híbrida); GII, GIV e GVI: sistemas adesivos autocondicionantes (reação-integração); GIII, GV e GVII: sistemas adesivos autocondicionantes (desproteinização). Os dentes foram restaurados com resina composta Filtek Z-250 3M™/ESPE™. 24 horas após, os dentes foram seccionados usando um disco de diamante montado numa máquina LABCUT 1010, e obter seções perpendiculares da interface adesiva, com uma área de seção transversal de aproximadamente 0,7 mm2 . Foram selecionados 3 espécimes por grupo, os quais foram preparados e analisados em microscópio eletrônico de varredura de emissão de campo e “confocal laser scanning microscope”, os espécimes restantes foram submetidos ao teste de microtração, numa máquina de ensaios universal, a uma velocidade de 1 mm/min. Os modos de fratura foram visualizados utilizando um microscópio óptico. Para cada um dos sistemas adesivos autocondicionantes foi realizado um teste de viscosidade. Os valores de resistência foram submetidos ao teste estatístico de Kruskal-Wallis. Os resultados mostraram que o sistema adesivo autocondicionantes XENO®III após a desproteinização com NaOCl 5,2% (43,60±11,44 MPa), apresentou os maiores valores de resistência adesiva. Os menores valores foram observados no sistema adesivo autocondicionante One Coat SE Bond com e sem desproteinização (27,50±8,75 MPa) e (27,07±7,27 MPa) respectivamente. O Self Etch Bond com NaOCl 5,2%, apresentou maiores valores de resistência adesiva. A análise de microscopia permitiu observar as diferenças entre as interfaces adesivas obtidas (camada híbrida, reação-integração, e desproteinização). Para este estudo foi possível demonstrar que, a desproteinização dentinária por meio da aplicação de NaOCl 5,2% por 40 seg., não influenciou na resistência adesiva, dos adesivos autocondicionantes One Coat SE Bond e do XENO®III. No adesivo autocondicionante Self Etch Bond com NaOCl, a resistência adesiva aumentou significativamente. Palavras-Chave: Sistemas Adesivos; Hipoclorito de sódio; Resistência Adesiva à Tração.
114

Controle de Salmonella sp. em carcaças de frango pelo uso de descontaminantes químicos durante o processo de abate e as consequências na qualidade da carne /

Nicolau, Juliana Pampana. January 2016 (has links)
Orientador: Elisa Helena Giglio Ponsano / Coorientador: Marcos Franke Pinto / Banca: Maria Luiza Poiatti / Banca:Andréa Fontes Garcia / Banca: Flavia Lombardi Lopes / Banca:Marcelo Vasconcelos Meireles / Resumo: O Brasil é um grande produtor e exportador de carne de frango e, por isso, deve primar em fornecer o produto com segurança e qualidade. A Salmonella sp. destaca-se dentre os patógenos que podem contaminar a carne de frango e, para minimizar sua prevalência, a legislação brasileira permite o uso de até 5 ppm de hipoclorito de sódio no pré-resfriamento de carcaças de frango, enquanto que outros países preconizam o uso de ozônio e ácido láctico para a mesma finalidade. Este estudo objetivou verificar se diferentes concentrações de hipoclorito de sódio, ozônio e ácido láctico, utilizados isoladamente e em conjunto na descontaminação de carcaças de frango, são eficazes na eliminação desse patógeno e se provocam alterações em suas características de qualidade. Para pesquisar a eliminação da Salmonella sp., carcaças foram contaminadas com Salmonella Enteritidis e, em seguida, submetidas aos tratamentos com os sanitizantes. Para a pesquisa sobre as características da carne, as carcaças foram tratadas com os sanitizantes e analisadas quanto a pH, rancidez, cor e sabor. O hipoclorito de sódio foi o sanitizante mais eficiente para a descontaminação das carcaças e, também, o que mais provocou alterações nas características da carne, como a redução do pH e da rancidez e o aumento da luminosidade. Na análise sensorial, não se encontrou diferença entre os tratamentos com os diferentes sanitizantes. Concluiu-se que o uso isolado do hipoclorito de sódio na concentração máxima permitida no Bra... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Brazil is a major producer and exporter of poultry meat and must aim to provide the product with safety and quality. Salmonella sp. is among the pathogens that can contaminate poultry meat and, to minimize its prevalence, Brazilian laws allow the use of up to 5 ppm of sodium hypochlorite in the precooling of poultry carcasses while other countries recommend the use of ozone and lactic acid. This study aimed to investigate if sodium hypochlorite, ozone and lactic acid used in different concentrations for the decontamination of broilers carcasses, alone or in combination, are effective for eliminating this pathogen and if their use may change the quality characteristics of broiler meat. To investigate the elimination of Salmonella sp., the carcasses were contaminated with Salmonella Enteritidis and then treated with the sanitizers. For the evaluation of the meat characteristics, carcasses were treated with the sanitizers and analyzed for pH, rancidity, color and flavor. Sodium hypochlorite was the most efficient sanitizer for the decontamination of the carcasses and also the one which caused most changes in meat characteristics, such as lowering pH and rancidity and increasing lightness. Sensory analysis showed no difference among treatments. In conclusion, the use of sodium hypochlorite alone at the maximum allowable concentration in Brazil was enough to eliminate the pathogen, not requiring the use of any other sanitizers for the same purpose, and the changes it caused to mea... (Complete abstract click electronic access below) / Doutor
115

Eficácia da ação antimicrobiana de soluções químicas - hipoclorito alcalino e mamona (Ricinus communis) - frente a micro-organismos específicos / Efficacy of antimicrobial action of chemical solutions - alkaline hypochlorite and castor oil (Ricinus communis) - against specific microorganisms

Salles, Marcela Moreira 27 June 2013 (has links)
O objetivo deste trabalho foi avaliar, por meio de estudo laboratorial e clínico, a eficácia de soluções de hipoclorito alcalino (0,25% e 0,5%) e à base de mamona (Ricinus communis) a 10% quanto à ação antimicrobiana frente a micro-organismos específicos, por meio da contagem de Unidades Formadoras de Colônias (UFC). No estudo laboratorial, a partir de matrizes metálicas quadrangulares (10 x 2 mm), foram confeccionados 360 corpos de prova de resina acrílica termopolimerizável (Lucitone 550), os quais foram esterilizados em micro-ondas (650W, por 6 minutos), contaminados com cepas de Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, Bacillus subtilis, Escherichia coli, Streptococcus mutans, Enterococcus faecalis e Candida glabrata e imersos (20 minutos) em soluções higienizadoras (n=10): Grupo A - Hipoclorito de sódio 0,25%; Grupo B - Hipoclorito de sódio 0,5%; Grupo C - Solução de mamona a 10%; Grupo D (Controle positivo) - solução salina e Grupo E (Controle negativo) - sem contaminação e imerso em solução salina (n=5). Em seguida, foram lavados em solução salina e imersos em meio de cultura líquido (Letheen), a partir do qual foram obtidas diluições seriadas (100 e 10-3), as quais foram semeadas em meios de cultura seletivos. Após incubação a 37ºC por 24 horas, as colônias foram contadas e os valores de UFC/mL calculados. No estudo clínico, 64 pacientes, usuários de próteses totais, foram orientados a escovar suas próteses (escova Bitufo® e sabonete líquido neutro) três vezes ao dia e imergí-las (20 minutos), uma vez ao dia, em soluções: Solução 1 - Hipoclorito de sódio 0,25%; Solução 2 - Hipoclorito de sódio 0,5%; Solução 3 - Solução de mamona a 10% e Solução 4 - solução salina (controle). De acordo com uma sequência aleatorizada, cada solução foi utilizada por 7 dias, com um período de wash out entre elas. A avaliação da ação antimicrobiana foi realizada antes dos uso dos produtos (Baseline) e após os 7 dias de uso de cada uma das soluções, por meio da contagem de Unidades Formadoras de Colônias (UFC) de Streptococcus mutans, Candida spp. e gram negativos. Para coleta do biofilme, cada prótese total superior foi colocada em placa de Petri e a superfície interna escovada (escova Tek e solução salina) por 2 minutos, sendo a suspensão transferida para tubo de ensaio. Após diluições decimais (100 até 10-3), alíquotas de 50 &mu;L foram semeadas em placas de Petri contendo Mitis Salivarius Agar Base, Chromagar® Candida e Mac Conkey Agar para a detecção de Streptococcus mutans, Candida spp. ou gram negativo, respectivamente. Após incubação a 37ºC (em microaerofilia durante 48-72 horas para grupo mutans e aerobiose durante 48 horas para Candida spp. e gram negativo), de acordo com morfologia típica, o número de colônias características foi mensurado e o número de UFC/mL calculado. Os dados obtidos foram transformados de acordo com a fórmula log10 (UFC+1) e analisados estatisticamente por meio do teste t de Student (&alpha;=0,05), para a análise laboratorial, e teste de Friedman (&alpha;=0,05), para a análise clínica. Os resultados mostraram que, no estudo laboratorial, as soluções de hipoclorito de sódio (0,25% e 0,5%) eliminaram completamente todos os micro-organismos. A solução de mamona eliminou completamente B. subtilis, não apresentou efeito sobre E. faecalis e apresentou ação antimicrobiana moderada frente às demais cepas, havendo redução significante (p < 0,05) do número de UFC quando comparado com o grupo D (controle positivo). No estudo clínico, houve diferença significante entre as soluções (P < 0,001), sendo que o hipoclorito de sódio a 0,5% apresentou ação efetiva sobre todos os micro-organismos avaliados (Candida spp., S. mutans e gram negativos); o hipoclorito de sódio 0,25%, ação efetiva sobre S. mutans e moderada sobre Candida spp. e gram negativos, e a solução de mamona, ação efetiva sobre S. mutans e moderada contra Candida spp. A espécie de Candida mais frequentemente isolada foi C. albicans, seguida pelas espécies C. tropicalis e C. glabrata. Concluiu-se que a solução de hipoclorito de sódio 0,5% foi a mais efetiva, apresentando ação antimicrobiana sobre ambos os biofilmes (in vitro e in vivo), seguida pela solução de hipoclorito de sódio 0,25% que apresentou ação antimicrobiana sobre o biofilme in vitro e sobre S. mutans (biofilme in vivo). A solução de mamona (10%) foi a menos efetiva, apresentando ação antimicrobiana sobre B. subtilis (biofilme in vitro) e S. mutans (biofilme in vivo). / The objective of this study was to evaluate, through laboratory and clinical study, the efficacy of alkaline hypochlorite solutions (0.25% and 0.5%) and 10% castor oil solution (Ricinus communis) about the antimicrobial action against specific microorganisms, by counting the number of Colony Forming Units (CFU). In the laboratory study, 360 denture base acrylic resin specimens (Lucitone 550) were obtained from square metal matrix (10 mm x 2 mm), which were sterilized with microwave (650W, for 6 minutes), contaminated with Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, Bacillus subtilis, Escherichia coli, Streptococcus mutans, Enterococcus faecalis and Candida glabrata and immersed (20 minutes) in the hygiene solutions (n = 10): Group A - 0.25% Sodium Hypochlorite; Group - B - 0.5% Sodium hypochlorite; Group C - 10% Castor oil solution; Group D (Positive Control) - saline and Group E (Negative Control) - no contamination and immersed in saline (n = 5). The specimens were washed in saline solution and immersed in liquid culture medium (Letheen), from which were obtained serial dilutions (100 to 10-3) and seeded into selective solid media. After incubation at 37º C for 24 hours, the colonies were counted and the values of CFU/mL calculated. In the clinical study, 64 complete denture wearers were instructed to brush their dentures (Bitufo ® brush and liquid neutral soap) three times a day and to soak them (20 minutes), once a day, in the solutions: Solution 1 - 0.25% Sodium Hypochlorite; Solution 2 - 0.5% Sodium hypochlorite; Solution 3 - 10% Castor oil and Solution 4 - saline (control). According to a randomized sequence, each solution was used for 7 days, with a period of wash out between them. The evaluation of the antimicrobial action was performed before the use of the products (Baseline) and after 7 days after using each solution, by counting the Colony Forming Units (CFU) of Streptococcus mutans, Candida spp. and gram negative. For collection of the biofilm, each upper complete denture was placed in a Petri dish, the internal surface was brushed with saline solution for 2 minutes and the suspension was transferred to a test tube. After decimal dilutions (100 to 10-3), aliquots of 50 uL were seeded inside Petri dishes containing Mitis Salivarius Agar Base, Candida Chromagar ® and Mac Conkey Agar for the detection of Streptococcus mutans, Candida spp. or gram negative, respectively. After incubation at 37° C (in microaerophilic conditions for 48-72 hours for mutans and aerobiosis for 48 hours for Candida spp. and gram negative), in accordance with characteristic morphology, the number of characteristic colonies was countedand the number of CFU/ml calculated. Data were processed following transformation into the formula log10 (CFU +1) and statistically analyzed using the Student t test (&alpha; = 0.05) for laboratory analysis, and Friedman test (&alpha; = 0.05), for clinical analysis. The results showed that, in the laboratory study, sodium hypochlorite (0.25% and 0.5%) eliminated completely all microorganisms. The Castor oil solution eliminated B. subtilis, had no effect on E. faecalis and showed moderate antimicrobial activity against other strains, with a significant reduction (p <0.05) in the number of CFU compared with group D (positive control). In the clinical study, there was significant difference between the solutions (P <0.001), and 0.5% sodium hypochlorite had effective action on all evaluated microorganisms (Candida spp., S. mutans and gram negative); 0.25% sodium hypochlorite had effective action on S. mutans and moderate on Candida spp. and gram negative, and the castor oil solution had effective action on S. mutans and moderate against Candida spp. . The Candida species most often isolated was C. albicans, followed by the species C. tropicalis and C. glabrata. It was concluded that the solution of 0.5% sodium hypochlorite was the most effective presenting antimicrobial action on both biofilms (in vitro and in vivo), followed by 0.25% sodium hypochlorite solution that showed antimicrobial activity on biofilms in vitro and on S. mutans (biofilm in vivo). The 10% castor oil was less effective, with antimicrobial action on Bacillus subtilis (biofilm in vitro) and S. mutans (biofilm in vivo).
116

Utilização da terapia fotodinâmica associada ou não ao hipoclorito de sódio na instrumentação de canais radiculares contaminados com Enterococcus faecalis / The use of photodynamic therapy associated or not to sodium hypochlorite in the instrumentation of radicular canals contaminated by Enterococcus faecalis

Lilian Ferreira Freitas 22 May 2009 (has links)
O presente trabalho teve por objetivo avaliar a ação do laser de baixa intensidade associado ao corante azul de toluidina, como agente bactericida durante a fase de instrumentação dos canais radiculares, comparando sua utilização associada ou não ao hipoclorito de sódio 0,5%. Para tal, 90 caninos humanos foram instrumentados, autoclavados e 88 imersos em caldo TSB(Tryptcase Soy Broth). Em seguida foram inoculados com suspensão de E. faecalis e incubados em estufa a 37C, por 72 horas, para permitir a formação do biofilme. As amostras foram randomicamente divididas em 4 grupos de 22 dentes cada e 1 grupo controle negativo com 2 dentes. Grupo I: reinstrumentados e irrigados com soro fisiológico com posterior aplicação de terapia fotodinâmica (PDT); Grupo II: reinstrumentados e irrigados com hipoclorito de sódio a 0,5% com posterior aplicação de PDT; Grupo III: reinstrumentados e irrigados com hipoclorito de sódio a 0,5%; Grupo IV controle positivo: não foi realizado nenhum tipo de tratamento antes da coleta do material e Grupo V controle negativo:não foram contaminados. Para a coleta da dentina intracanal utilizou-se uma broca Gates Glidden número 6. A atividade antimicrobiana foi avaliada por meio da contagem de UFCs (unidades formadoras de colônias). Os dentes foram então imersos em meio seletivo para enterococos, incubados em estufa a 37 C por 72 horas e avaliados quanto à alteração de coloração do meio. Todas as amostras, exceto o controle negativo, apresentaram-se positivas. Com a finalidade de certificar-se da formação do biofilme e da confirmação dos resultados das contagens das UFCs, 9 amostras foram avaliadas ao MEV (microscopia eletrônica de varredura). Para a análise dos resultados utilizou-se o teste de Kruskal-Wallis e o teste de comparações múltiplas de Tukey, ambos com o nível de significância de 5%. Baseado nos resultados obtidos parece-nos lícito concluir que não houve diferença estatística significante entre o grupo hipoclorito e o hipoclorito com laser e que PDT associada à instrumentação com soro fisiológico não foi capaz de eliminar o E. faecalis de forma significativa. / This current paper aims to assess the action of low-intensity laser together with toluidine blue as a bactericidal agent during the instrumentation phase of radicular canals, comparing its associated or non-associated use with sodium hypochlorite 0.5%. To do so, 90 human canines were instrumented, autoclaved, and 88 were immersed into TSB, and were then inoculated with an E. faecalis suspension and brought into an incubator at 37 degrees Celsius for 72 hours in order to allow the formation of biofilm. The samples were randomly divided into 5 groups, 4 of which composed of 22 samples each plus 1 negative control. Group I: reinstrumented and irrigated with saline solution and subsequent application of photodynamic therapy (PDT); Group II: reinstrumented and irrigated with sodium hypochlorite 0.5% and subsequent PDT application; Group III: reinstrumented and irrigated with sodium hypochlorite 0.5%; Group IV: positive control (no previous treatment before material collection); Group V: negative control (2 samples) with no contamination. The collection of intracanal dentin was obtained by using a Gates Glidden drill #6. The antimicrobial activity was assessed by CFUs counting. The teeth were then immersed in a selected medium for Enterococcus, incubated at 37 degrees Celsius for 72 hours. They were then assessed for medium turbidity. All samples, with the exception of the negative control, showed positive. In order to make sure of the formation of biofilm and the confirmation of the CFUs counting, 9 samples were scavenged under the electron microscope. For result assessment, the Kruskal-Wallis test and the Tukeys multiple comparison test were utilized, presenting both tests a rate and significance of 5%. Based on the results obtained, we may licitly conclude that there was no significant statistical difference between the hypochlorite group and the hypochlorite group with laser. We may still conclude that PDT associated with saline solution instrumentation was not possible to significantly eliminate E. faecalis.
117

EFEITO DA DESINFECÇÃO DE CANAIS PROTÉTICOS NA RESISTÊNCIA ADESIVA DE PINOS DE FIBRA DE VIDRO À DENTINA RADICULAR / EFFECTS OF DISINFECTION OF ROOT CANAL IN THE BOND STRENGTH OF GLASS FIBER POSTS IN RADICULAR DENTIN

Ravanello, Luciane Noal 31 March 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The root canal preparation for placement of endodontical posts, more than in coronary preparations, produces smear layer rich in remains of dentine, filling materials and microorganisms, which may decrease the penetration and action of the adhesives, as well it favors the infection recidivation. This study investigated the effect of root canal disinfection on bond strength of glass fiber posts (White Post DC) cemented with two adhesive cements at cervical, middle and apical root. Sixty roots were randomly divided into six groups (n = 10) in accordance with the cleaning technique: water (control), 5% sodium hypochlorite and sodium hypochlorite 5% + ultrasonic agitation; and the strategies of cementation: etching with phosphoric acid 37% (Condac, FGM) +_Adper Single Bond 2 adhesive resin + RelyX ARC adhesive resin cement conventional or self-adhesive resin cementRelyX U100 (3M ESPE). After fiber posts cementation and core build-up with composite resin Z350 (3M ESPE), the reconstructed teeth were subjected to 1,000,000 cycles of mechanical fatigue (ER 11000, manufacturer, city, state, country). The specimens were then sectioned into slices of 2.0 mm thickness with a cutting machine (Labcut 1010, Extec, city, state, country) for the push-out test (EMIC City, PR, Brazil). The results were analyzed statistically (three-way ANOVA and Tukey´s test). Cleaning methods did not interfere on the bond strength in the groups with conventional cement and there was no difference between the thirds in the control groups and sodium hypochlorite, but in groups that used sodium hypochlorite associated with ultrasonic agitation, the cervical third provided significantly higher bond strength. In groups associated with the self-adhesive cement the bond strength was higher in the control group in all thirds; in the sodium hypochlorite group, the bond strength was greater in the apical third. However, there was no significant difference between the thirds in the control groups and sodium hypochlorite associated with ultrasonic agitation. The selfadhesive cement has provided higher bond strength than the conventional in all groups. In this study, the use of sodium hypochlorite reduced the bond strength for the self-adhesive cement. / O preparo do canal protético para colocação de pinos, mais do que em preparos coronários, produz smear layer rica em restos de dentina, materiais obturadores e microorganismos, que podem diminuir a penetração e a ação dos adesivos, bem como favorece a recidiva de processos infecciosos. Este estudo investigou o efeito da desinfecção dos canais protéticos na resistência adesiva de pinos de fibra de vidro (White Post DC, FGM, Joinvile, SC, Brasil) cimentados com 2 cimentos adesivos nos terços cervical, médio e apical da raiz. Sessenta raízes foram aleatoriamente divididas em 6 grupos (n=10) conforme a técnica de limpeza: água (controle); hipoclorito de sódio 5% e hipoclorito de sódio 5% + ultrassom; e a estratégia de cimentação: condicionamento com ácido fosfórico 37% (Condac, FGM) + sistema adesivo Adper Single Bond 2 (3M ESPE, St Paul, MN, EUA) + cimento adesivo convencional RelyX ARC ou cimento resinoso auto-adesivo RelyX U100 (3M ESPE). Após a cimentação dos pinos de fibra e a reconstrução do núcleo coronário com resina composta Z350 (3M ESPE), os dentes reconstruídos foram submetidos a 1.000.000 de ciclos de fadiga mecânica (ER 11000, ERIOS, São Paulo, SP, Brasil). Os espécimes foram, então, seccionados em fatias de 2,0 mm de espessura em uma máquina de corte (Labcut 1010, Extec Corp., Enfield, CT, USA) para o teste de push-out (EMIC Equipamentos e Sistemas Ltda./ São José dos Pinhais-PR, Brasil). Os resultados foram analisados estatisticamente (Análise de variância de 3 fatores e Tukey). Os métodos de limpeza não interferiram sobre a resistência adesiva nos grupos com o cimento convencional; não houve diferença entre os terços nos grupos controle e hipoclorito de sódio, mas nos grupos que usaram hipoclorito de sódio associado a ultrassom o terço cervical proporcionou resistência adesiva significativamente maior. Nos grupos associados com o cimento autoadesivo a resistência adesiva foi maior no grupo controle, em todos os terços; no grupo hipoclorito de sódio, a resistência adesiva foi maior no terço apical. Entretanto, não houve diferença entre os terços nos grupos controle e hipoclorito de sódio associados ao ultrassom. O cimento autoadesivo proporcionou resistência de união maior que o convencional em todos os grupos. Neste estudo, a utilização do hipoclorito de sódio diminuiu a resistência de união para o sistema autoadesivo.
118

PRÉ-TRATAMENTOS DENTINÁRIOS: EFEITO NA RESISTÊNCIA DE UNIÃO UTILIZANDO SISTEMA ADESIVO UNIVERSAL / DENTIN PRETREATMENT: EFFECT ON BOND STRENGTH USING UNIVERSAL ADHESIVE SYSTEM

Monteiro, Leticia Lese 27 June 2014 (has links)
The aim of this study was to evaluate the effect of dentin pretreatment with chlorhexidine and sodium hypochlorite in the bond strength of adhesive systems. Seventy-two sound human third molars were divided in 12 groups according to the adhesive system (Single Bond 2 - SB2, Clearfil SE Bond - SE, Single Bond Universal - SBU ) pretreatment (control, 2% chlorhexidine and hypochlorite sodium 10% ) and strategies ( self-etching or total etching ). The adhesive protocols followed the recommendation of the respective manufacturers and resin restorations were made of 5mm. After restoration, the teeth were stored in distilled water for 24 hours and sectioned to obtain specimens with interface area of 1.0 mm². Then, the specimens were subjected to microtensile testing in a universal testing machine until its failure. The results of the test microtensile bond strength were recorded in Mpa. Mean and standard deviation were calculated for each of the experimental groups. The mean bond strengths were subjected to analysis of variance (ANOVA) and differences between groups were assessed by Tukey test. For all analyzes the significance level was 5%. Analysis of variance showed that treatment surface factor exerted significant influence on the values of bond strength. The use of sodium hypochlorite to 10 % reduced the values of bond strength when compared to other treatments for all adhesive systems and should not be considered as a pretreatment of dentin. / O objetivo deste estudo foi avaliar o efeito de pré-tratamentos dentinários com clorexedina e hipoclorito de sódio, na resistência de união de sistemas adesivos. Setenta e dois terceiros molares humanos hígidos foram alocados em quatro grupos experimentais de acordo com o sistema adesivo (Single Bond 2 SB2, Clearfil SE Bond SE, Single Bond Universal - SBU) pré-tratamento (controle, Clorexedina 2% e Hipoclorito de Sódio 10%) e estratégias de uso (autocondicionante ou condicionamento ácido total). Os protocolos adesivos seguiram recomendação dos respectivos fabricantes e restaurações de resina de 5mm foram confeccionadas. Após restaurados, os dentes foram armazenados em água destilada durante 24h e seccionados para obtenção dos espécimes com área na interface de 1,0 mm² . Em seguida, os espécimes foram submetidos ao ensaio de microtração em máquina de ensaios universais até a ruptura. Os resultados de resistência adesiva ao ensaio de microtração foram registrados em MPa e elaboradas médias e desvios padrão para cada um dos grupos experimentais. As médias de resistência adesiva foram submetidas à análise de variância (ANOVA) e as diferenças entre os grupos foram submetidas ao teste de Tukey. Para todas as análises, o nível de significância considerado foi de 5%. A análise de variância mostrou que o fator tratamento de superfície exerceu influência significante nos valores de resistência de união. A aplicação de hipoclorito de Sódio a 10% reduziu os valores de resistência de união quando comparados aos tratamentos controle e clorexedina para todos os sistemas adesivos testados, não devendo portanto ser considerado como um pré-tratamento em dentina.
119

Comparação entre os métodos químico-mecânicos, Carisolv® e Papacárie®, com método mecânico manual na remoção de dentina cariada

Lima, Daniela Coelho de [UNESP] 15 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-15Bitstream added on 2014-06-13T20:56:48Z : No. of bitstreams: 1 lima_dc_me_araca.pdf: 774525 bytes, checksum: 538ef364e5dbda059945006d226d6a66 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Na Odontologia atualmente têm-se enfatizado a prática de técnicas menos invasivas para a remoção de tecido cariado, que preservem ao máximo as estruturas dentárias. O interesse clínico e laboratorial por essas técnicas tem aumentado em função da realização de estudos que comprovaram a eficácia da remoção manual de dentina infectada, bem como as vantagens da técnica conservadora e indolor. O objetivo desse estudo foi analisar e comparar os tratamentos mecânico manual (ART convencional) e químico-mecânicos (CarisolvTM e Papa-cárie®) na remoção de dentina cariada, por meio da contagem de Streptococcus mutans e Lactobacillus e avaliação clínica de sintomatologia dolorosa durante o procedimento restaurador. Para a realização do presente estudo foram selecionadas 32 crianças, de ambos os sexos, com idade entre 6 e 10 anos, que apresentavam no mínimo dois molares decíduos, com exposição de dentina cariada. As crianças foram divididas aleatoriamente em dois grupos homogêneos, totalizando 64 dentes. O grupo I foi submetido à remoção mecânica em um elemento dental e em outro dente a químico-mecânica com o uso de Carisolv e o grupo II, a remoção mecânica e a químico-mecânica com o uso do Papacárie®. Durante a realização dos tratamentos foram feitas coletas de dentina, antes e após a remoção de tecido cariado e aplicação de um questionário para a avaliação clínica. Posteriormente, foram realizadas diluições seriadas e cultivo das amostras em meios específicos, Mitis salivarius bacitracina sacarose para a contagem de Streptococcus mutans e Rogosa, para contagem de Lactobacillus ssp. Após o período de incubação, a 37º C e 72 horas, foi realizada a contagem de Unidades Formadoras de Colônias (UFC) e obtidos os valores médios do número de bactérias. / In Dentistry, nowadays, it has been emphasizing the practice of techniques less invasive for the removal of decayed tissue that preserve the maximum the dental structure. The clinical laboratorial interest for those techniques have been increasing due to studies that proved the effectiveness of the manual removal of infected dentine, as well as the advantages of the conservative and painless technique. The objective of this study was to analyze and to compare the manual mechanic (conventional ART) and chemical-mechanic (Carisolv and Papa-carie®) treatments in the removal of decayed dentine, through the score of Streptococcus mutans and Lactobacillus and clinical evaluation of pain symptoms during the restorative procedure. For the performance of the present study 32 children were selected, of both genders, with age between 6 and 10 years that presented at least two deciduous molars, with exhibition of decayed dentine. The children were divided at random in two groups, summing 64 teeth. The group I was submitted to the mechanical and chemical-mechanical removal with the use of Carisolv and the group II, mechanical and chemical-mechanic removal with Papacárie®. During the performance of the treatments, dentine sample were collected, before and after the removal of decayed tissue and application of a questionnaire for the clinical evaluation. Later, it was carried out seriate dilutions and cultivation of the samples in Mitis- salivarius bacitracin sucrose for the score of Streptococcus mutans and Rogosa, for score of Lactobacillus ssp. After the incubation period, at 37° C and 72 hours, it was carried out the score of the ColonY Forming Units (CFU) and obtained the mean values of the bacteria number.
120

RESISTÊNCIA DE UNIÃO DE SISTEMAS ADESIVOS ATUAIS EM DENTINA SUBMETIDA A DIFERENTES TRATAMENTOS / BOND STRENGTH OF ADHESIVE SYSTEMS IN DENTIN SUBMITTED TO DIFFERENT TREATMENTS

Montagner, Anelise Fernandes 17 December 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Studies have shown that the longevity of adhesive restorations is adversely affected by collagen degradation. The purpose of this study was to evaluate the effect of different treatments on the bond strength of adhesive systems in different dentin surfaces. Forty healthy human third molars were randomly assigned to 24 experimental groups (n = 5) according to adhesive systems (Single Bond - SB, Clearfil SE Bond - SE, Adper SE Plus - AP, G Bond - GB), treatments (control and deproteination) and dentin surfaces (proximal, superficial and deep occlusal). For the deproteinization treatment was applied 10% sodium hypochlorite, for 1 minute, to previously conditioned dentin and the adhesive systems were applied according to manufactures directions. In each specimen were made cylindrical cavities in the proximal and occlusal surfaces and, after immersion in destilated water for 24 hours, one slice and 2 slices of occlusal and proximal surfaces were, respectively, obtained. The slices were submitted to push-out test and after it a fracture analysis was performed. The values in MPa were submitted to ANOVA 3-factors and Tukey (p <0.05), indicating a statistically significant difference between the adhesive systems (p = 0.000) and dentin surfaces (p = 0.005), However, the type of treatment (p = 0.058) did not significantly affect the values of bond strength. The bond strength values were higher for proximal surface, followed by superficial oclusal and later by deep occlusal, being influenced by the adhesive system. The collagen removal from the conditioned surface can be considered a way to decrease the sensitivity technique without compromising the adhesive effectiveness. / Estudos têm demonstrado que a longevidade de restaurações adesivas é negativamente afetada pela degradação das fibras colágenas. O objetivo deste estudo foi avaliar o efeito de diferentes tratamentos na resistência de união de sistemas adesivos em diferentes regiões dentinárias. Quarenta dentes terceiros molares humanos hígidos foram alocados randomizadamente em 24 grupos experimentais (n=5) de acordo com: tipo de sistema adesivo (Adper Single Bond - SB, Clearfil SE Bond - SE, Adper SE Plus - AP, G Bond - GB), tipo de tratamento (controle e desproteinização) e tipo de região dentinária (proximal, oclusal superficial e profunda). Para desproteinização da dentina foi utilizado hipoclorito de sódio 10%, por 1 minuto, na dentina previamente condicionada; e os sistemas adesivos foram aplicados conforme indicações dos fabricantes. Cavidades cilíndricas foram realizadas na superfície proximal e oclusal de cada espécime, de onde se obteve, 24 horas após o armazenamento em água destilada, 1 slice e 2 slices, respectivamente. Os slices foram submetidos a teste de push-out e logo após, a análise de fratura. Os valores obtidos em MPa foram submetidos à análise de variância de 3-fatores e teste Tukey (p<0.05), indicando diferenças estatisticamente significantes entre o tipo de sistema adesivo (p=0.000) e o tipo de região dentinária (p=0.005), porém o tipo de tratamento (p=0.058) não afetou significativamente os valores de resistência de união. Os valores de resistência de união foram maiores para superfície proximal, seguida de oclusal superficial e posterior oclusal profunda, sendo influenciados pelo tipo de sistema adesivo. A remoção de colágeno da superfície condicionada pode ser considerada caminho para diminuir a sensibilidade da técnica sem comprometer a efetividade adesiva.

Page generated in 0.0254 seconds