Fundamental Studies on Direct Injection Nebulisers for Sample Introduction in ICP Spectrometry : Aerosol Properties, ICP Characteristics and Analytical PerformanceGoitom Asfaha, Daniel January 2006 (has links)
The performance of different types of nebulisers: Vulkan direct injection nebuliser (Vulkan DIN), direct injection high efficiency nebuliser (DIHEN), microconcentric nebuliser coupled to cyclonic or double pass spray chamber (MCN-C or MCN-DP, respectively) was investigated and compared when used for sample introduction to ICP-MS or ICP-OES. With ICP-OES, in axial viewing mode, intensity distributions across the radius of the plasma (radial intensity profiles) were determined for different spectral lines with Esum 1.85-15.41 eV to determine fundamental plasma properties for various matrices using Vulkan DIN and MCN-C. The results showed that with the MCN-C the ionisation temperature (Tion) was about the same across the measured region of the plasma (±3.0 mm) whereas with the Vulkan DIN the Tion was significantly lower in the centre of the plasma. A large deviation from local thermodynamic equilibrium, as well as deteriorated stability, was observed for the plasma when using the Vulkan DIN. With ICP-MS noise power spectra (NPS) were generated to identify sources of noise. NPS showed that the magnitude of white noise for the tested sample introduction systems decreased in the following order: Vulkan DIN > DIHEN > MCN-C > MCN-DP. This order follows the decrease of mean droplet size and span of the size distribution, indicating that the white noise is caused by spatial and temporal non-uniform desolvation and ionisation. Another source of noise arose from the peristaltic pump and the magnitude of pump interference noise decreased in the following order: DIHEN > MCN-C/DP > Vulkan DIN. Mains power interference noise and 1/f noise were lower for the direct injection nebulisers compared to the spray chamber systems. The contribution or effects of these noise components on relative standard deviations of steady-state ion-count rate and isotope ratio measurements is discussed in this thesis. Aerosols generated by the Vulkan DIN and the DIHEN were also directly characterised using Particle Dynamic Analysis. The Vulkan DIN produced particles with a mean diameter of ~30 µm and a size distribution between 2-80 µm. With the DIHEN the corresponding values were ~11 µm and 1-40 µm, respectively, with a few particles at 55-78 µm. The mean velocity of particles from the Vulkan DIN was ~10 m s-1 and from the DIHEN ~18 m s-1. The lower velocity allows longer residence time counteracting the effects of the larger droplet size.
|
182 |
Determinação de elementos maiores e traço em tecidos de moluscos bivalves por espectrometria de emissão óptica com plasma indutivamente acopladoSantil, Darlan da Silva January 2010 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-08-30T17:05:18Z
No. of bitstreams: 1
Dissertação - Darlan S Santil.pdf: 1852568 bytes, checksum: 56dd8cda0c9cfac1cef7ea49ee2facfb (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-02T15:26:24Z (GMT) No. of bitstreams: 1
Dissertação - Darlan S Santil.pdf: 1852568 bytes, checksum: 56dd8cda0c9cfac1cef7ea49ee2facfb (MD5) / Made available in DSpace on 2016-09-02T15:26:24Z (GMT). No. of bitstreams: 1
Dissertação - Darlan S Santil.pdf: 1852568 bytes, checksum: 56dd8cda0c9cfac1cef7ea49ee2facfb (MD5) / CAPES / O presente estudo propõe a determinação de elementos maiores e traço em invertebrados marinhos por
Espectrometria de Emissão Óptica com Plasma Indutivamente Acoplado (ICP OES) após um
procedimento assistido por radiação ultrassom e centrífuga, empregando ácidos diluídos. Um
planejamento Doehlert de três fatores foi aplicado para otimizar a extração dos elementos nas amostras
de bivalves (Mytella guyanensis, Anomalocardia brasiliana e Crassostrea rhizophorae). Os fatores
foram: concentração da mistura ácida (HCl + HNO3 + H3CCOOH; 1-3 mol L-1), tempo de centrifugação
(10-40 min.), e velocidade de rotação (6000-10000 rpm). A eficiência de extração expressa em
percentual foi escolhida como resposta analítica no processo de otimização. Além disso, todos os
experimentos foram realizados analisando o material de referência certificado NIST 1566b (tecido de
ostra). O percentual de recuperação obtida nas amostras de material de referência certificado pela
martiz Doehlert variou de 45-95, 8-52, 35-71, 67-102, 38-78, 61-92, 58-100, 39-85 e 51-91%,
respectivamente, para Ca, Cd, Cu, K, Mg, Mn, Na, Sr, e Zn. Todavia, ponto de máximo não foi obtido.
Portanto, a resposta múltipla foi escolhida para obtenção dos valores máximos de extração dos metais.
As seguintes condições experimentais da resposta múltipla foram selecionadas: 20 min de tempo de
extração, 9000 rpm de velocidade de rotação e 1,0 mol L-1 da mistura ácida. A fim de avaliar o efeito do
ultrassom na extração dos elementos, uma porção de tecido de ostra certificado foi sonicada por 15 min
em um banho de ultrassom à temperatura ambiente e a solução foi centrifugada nas condições
otimizadas. Os resultados mostraram que o uso da sonicação antes da centrifugação promoveu um
aumento na porcentagem de recuperação dos elementos estudados. A repetitividade do procedimento
auxiliado por centrífuga e ultrassom foi avaliada pela determinação de elementos maiores e traço em 10
replicatas do material certificado. Os desvios padrões relativos (RSD) para o procedimento proposto
variam entre 1,8 a 4,7. A exatidão do método foi confirmada pela análise de tecido de ostra certificado
(NIST 1566b) e por comparação de método analítico de referência com procedimento de digestão ácida
para o tratamento das amostras (microondas com cavidade). Os resultaldos da análise da exatidão de
alguns elementos estudados mostraram que não havia diferenças significativas (p<0,05) entre o método
proposto e o método de referência. Concomitantemente ao desenvolvimento do método analítico, as
concentrações dos elementos menores e maiores em amostras dos bivalves coletados ao longo da Baía
de Todos os Santos, Bahia, Brasil foram determinadas por ICP OES após o procedimento de digestão
ácida em bombas Parr. Os resultados da determinação revelaram que as concentrações de As, Cu e Zn
nos bivalves estavam acima dos limites máximos estabelecidos pela ANVISA e por agências
especializadas em saúde internacionais. Esses valores de concentração sugerem que deve ser feita
uma análise de risco a / The present study proposes the determination of major and trace elements in marine invertebrates by
Inductively Coupled Plasma Optical Emission Spectroscopy (ICP OES) after a procedure assisted by
ultrasound radiation and centrifugal, employing diluted acids. A three factor Doehlert design was applied
to optimize the extraction of elements in bivalves (Mytella guyanensis, Anomalocardia brasiliana and
Crassostrea rhizophorae). The factors were: concentration of acid mixture (HCl + HNO3 + H3CCOOH;
1-3 mol L-1), centrifugation time (10-40 min.), and rotation velocity (6000-10000 rpm). The extraction
efficiency, expressed as a percentage, was chosen as the analytical response in the optimization
process. In addition, all experiments were performed by analyzing the certified reference material NIST
1566b (oyster tissue). The percentage of recovery obtained in the samples of certified reference material
by Doehlert varied from 45-95, 8-52, 35-71, 67-102, 38-78, 61-92, 58-100, 39-85 and 51-91%,
respectively, for Ca, Cd, Cu, K, Mg, Mn, Na, Sr, and Zn. However, maximum point wasn’t obtained. So,
the multiple response was chosen to obtain the maximum extraction of the metals. The following
experimental conditions of multiple response were selected: 20 min of extraction time, 9000 rpm of the
speed centrifuge and 1.0 mol L-1 of the acid mixture. In order to evaluate the ultrasound effect on the
extraction of trace elements a portion of the certified oyster tissue sample was sonicated for 15min in an
ultrasonic bath at ambient temperature, and then the solution was centrifuged at the optimized
conditions. Results showed that the use of the sonication prior to the centrifugation promoted an increase
in the percentage of recovery for most studied elements. The repeatability of the centrifugation and ultra-
sound assisted procedure was evaluated by the determination of trace and major elements in 10
replicates of the oyster tissue certified material. The relative standard deviations (RSD) for the
centrifugation and ultrasound assisted procedure varied between 1.8 and 4.7%. The accuracy of the
method was confirmed by analysis of the certified oyster tissue (NIST 1566b) and by reference analytical
method comparison with acid digestion procedure for the sample treatment (microwave cavity). The
results of the analysis of the accuracy of some elements studied showed that there were no significant
differences (p <0.05) between the proposed method and the reference method. Concurrent with the
development of the acid extraction procedure, the major and trace concentrations of elements in mussel,
oyster and clams samples collected from along coastal the zones of Todos os Santos Bay were
determined by ICP OES after Parr acid digestion bombs. The results of determination showed that
concentrations of As, Cu and Zn in the bivalves were above the limits established by ANVISA and
international agencies specializing in health. These concentration values suggest that must be a health
risk analysis mainly in the communities that collect the shellfish as a subsistence activity.
|
183 |
Estratégias analíticas para determinação de urânio em amostras de águas e efluentes industriaisSantos, Juracir Silva 16 April 2013 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-03T14:38:28Z
No. of bitstreams: 2
Juracir Santos 2011-212 SLCF.docx: 14953 bytes, checksum: ecc1d6899f344c253ec324748e3c4cc7 (MD5)
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / Rejected by Ana Hilda Fonseca(anahilda@ufba.br), reason: Retirar arquivo em doc on 2013-04-16T16:32:47Z (GMT) / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-16T16:38:31Z
No. of bitstreams: 1
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-04-16T16:39:25Z (GMT) No. of bitstreams: 1
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / Made available in DSpace on 2013-04-16T16:39:26Z (GMT). No. of bitstreams: 1
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / CAPES / O trabalho foi desenvolvido no âmbito do projeto 993/2007 – “Desenvolvimento de estratégias analíticas para a determinação de urânio em amostras ambientais e industriais – Monitoramento ambiental da cidade de Caetité, Bahia” e viabilizado através de uma parceria firmada entre a Universidade Federal da Bahia e a Comissão Nacional de Energia Nuclear. Neste trabalho foram desenvolvidas estratégias para a determinação de urânio em amostras de águas naturais e efluentes provenientes de mina de urânio. Uma avaliação crítica da determinação de urânio por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) foi realizada usando planejamentos fatoriais e Doehlert envolvendo as variáveis: concentração de ácido, potência de radiofrequência e vazão do gás de nebulização. Simultaneamente, cinco linhas de emissão foram estudadas (367,007; 385,464; 385,957; 386,592 e 409,013 nm), na presença de HNO3, H3C2OOH ou HCl. As determinações empregando o HNO3 foram as mais sensíveis. Entre as variáveis estudadas, a vazão do gás de nebulização foi a mais significativa, para as cinco linhas de emissão. A presença de cálcio causou interferência na intensidade de emissão de algumas linhas e ferro não interferiu (pelo menos até 10 mg L−1) nas cinco linhas estudadas. A presença de outros 13 elementos foi avaliada simultaneamente e, não afetou a intensidade de emissão. Sob condições otimizadas, usando a linha 385,957 nm, o método permite a determinação de urânio com limite de quantificação de 30 μg L−1 e precisão, expressa como RSD, menor que 2,2% para as concentrações de urânio de 500 e 1000 μg L−1. Na segunda estratégia, um procedimento em fluxo, com alta sensibilidade foi proposto para a determinação de urânio em amostras de água. Uma cela de caminho óptico de 100 cm baseada em guia de onda com núcleo líquido (LCW) foi usada para aumentar a sensibilidade do método do arsenazo III e possibilitar a detecção de urânio para atender aos limites estabelecidos pela legislação ambiental vigente. O sistema de fluxo foi desenvolvido com microbombas solenoide, a fim de melhorar a mistura e minimizar o consumo de reagente, bem como a geração de resíduos. A resposta linear do método observada foi 5,0-150,0 µg L-1, com limite de detecção, RSD e frequência de amostragem estimados em 1,3 µg L-1 (99,7% de confiança), 0,7% (n = 20) e 40 determinações por hora, respectivamente. O consumo de arsenazo III foi reduzido em 1250 vezes em comparação com um procedimento de pré-concentração em fase sólida. A exatidão dos métodos foi confirmada pela análise de dois materiais de referência de laboratório fornecido pela CNEN. Além disso, uma amostra de efluente foi analisada por espectrometria de massas com plasma indutivamente acoplado (ICP-MS) e as recuperações foram satisfatórias. Os métodos desenvolvidos foram aplicados na determinação de urânio em água potável, de rio e de poço, e efluentes industriais provenientes das minas de extração de urânio da cidade de Caetité. Os resultados encontrados para urânio em amostras de água potável de Caetité estavam abaixo do limite de quantificação dos métodos, exceto para uma amostra de água de poço subterrâneo (17,0 ± 0,8 µg L-1) e uma amostra de água de rio coletada nas imediações da mina (9,6 ± 0,8 µg L-1). / Salvador
|
184 |
Distribuição de elementos essenciais e não essenciais em tecidos de diversas espécies de peixes da Baia de Todos os Santos, Bahia, BrasilSilva, Edevaldo da January 2012 (has links)
204 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-06-07T14:19:48Z
No. of bitstreams: 1
Tese - Edevaldo da Silva.pdf: 4398446 bytes, checksum: 204dadfa6748f55151b537b3ef5737f9 (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-06-07T14:42:55Z (GMT) No. of bitstreams: 1
Tese - Edevaldo da Silva.pdf: 4398446 bytes, checksum: 204dadfa6748f55151b537b3ef5737f9 (MD5) / Made available in DSpace on 2013-06-07T14:42:55Z (GMT). No. of bitstreams: 1
Tese - Edevaldo da Silva.pdf: 4398446 bytes, checksum: 204dadfa6748f55151b537b3ef5737f9 (MD5)
Previous issue date: 2012 / Nesse trabalho, foi investigada a bioacumulação e distribuição de 18 elementos
químicos, essenciais (Ca, Mg, P, K, Fe, Sr, Zn, Cu, Mn, Se, Cr, Ni, Mo) e
contaminantes (Cd, Pb, Li, Sb, As), em seis tecidos (músculo, guelras, estômago,
fígado, rim, gônadas) de seis espécies de peixes marinhos (Caranx latus -
guaricema, Archosargus rhomboidalis - sambúio, Sphyraena guachancho - bicuda,
mackerel Scomberomorus cavalla - cavala, Lutjanus synagris - vermelho, Bagre
marinus - bagre). As amostras foram adquiridas entre dezembro/2010 e
janeiro/2012, oriundas da zona costeira da Baía de Todos os Santos (BTS), em
Salvador, Bahia, Brasil. Os elementos foram quantificados por espectrometria de
emissão óptica com plasma indutivamente acoplado (ICP OES) e espectrometria de
massas com plasma indutivamente acoplado (ICP-MS). As faixas de concentração
encontradas para os macroelementos (mg g-1) foram: Ca (0,71-77,54), Mg (0,31-
3,60), P (4,90-98,95), K (4,75-20,88). Os elementos traços apresentaram as
seguintes faixas de concentrações (µg g-1): Sr (1,67-820,21), Fe (6,64-1853,65), Zn
(14,18-843,92), Cu (0,17-28,12), Mn (0,11-77,87), Cr (0,35-5,46), Se (0,57-12,5), Ni
(<0,024-15,57), Mo (<0,024-1,29), Cd (<0,004-0,961), Pb (<0,010-0,600), Li (<0,009-
1,38), As (0,49-27,31). Houve variações significativas nas concentrações dos
elementos entre os tecidos e entre as diferentes espécies. Os tecidos com maior
potencial de bioacumulação para os elementos traço foram as guelras, o fígado e o
rim. A análise multivariada (PCA) demonstrou não haver correlação entre as
medidas biométricas e as concentrações dos elementos químicos, mas, fortes
associações entre pares de elementos foram observadas (Mg-Ca; Sr-Ca; P-Ca; K-
Ca; Mn-Ca; Sr-Mg; K-Mg; P-Sr; K-Sr; Se-Fe; Cr-Fe). A presença de níveis maiores
que o tolerável, nos músculos, para Cr e As e a evidência de bioacumulação desses
e de outros elementos tóxicos, tais como Pb, Ni e Cd revelam a necessidade de
mais estudos visando a analise de especiação química, além de um programa de
monitoramento na região da Baia de Todos os Santos, para se verificar a
necessidade de prováveis ações remediadoras. / Salvador
|
185 |
Desenvolvimento de estratégias analíticas visando avaliação nutricional e toxicológica de arrozSilva, Douglas Gonçalves da 12 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-12-18T15:35:02Z
No. of bitstreams: 1
Tese Doutorado Douglas Gonçalves da Silva.pdf: 2348008 bytes, checksum: 01d5eb52cbdd6aa3d019b03a07db5771 (MD5) / Approved for entry into archive by Fatima Cleômenis Botelho Maria (botelho@ufba.br) on 2015-01-14T12:18:20Z (GMT) No. of bitstreams: 1
Tese Doutorado Douglas Gonçalves da Silva.pdf: 2348008 bytes, checksum: 01d5eb52cbdd6aa3d019b03a07db5771 (MD5) / Made available in DSpace on 2015-01-14T12:18:20Z (GMT). No. of bitstreams: 1
Tese Doutorado Douglas Gonçalves da Silva.pdf: 2348008 bytes, checksum: 01d5eb52cbdd6aa3d019b03a07db5771 (MD5) / CNPq / Neste trabalho foram desenvolvidas estratégias analíticas visando a determinação
de espécies metálicas em amostras de arroz utilizando procedimento de digestão
ácida em micro-ondas e em bloco digestor para o preparo das amostras. Na primeira
parte deste trabalho desenvolveu-se um sistema automático para determinação de
mercúrio em amostras de arroz empregando injeção em fluxo com multiseringa
(MSFIA) e detecção por fluorescência atômica com vapor frio (CV-AFS).
Inicialmente, empregou-se o planejamento fatorial completo para avaliação
preliminar das variáveis que afetavam o sistema. Em seguida, o planejamento
Doehlert foi utilizado com o objetivo de se obter condições ótimas (SnCl2 3% (m/v)
em HCl 2%; vazão da amostra 3 mL min-1 e HNO3 8% (v/v)). O LD e LQ foram iguais
a 0,48 e 1,61ng g -1, respectivamente. O desvio padrão relativo foi menor que 2%
para uma amostra com concentração de mercúrio igual a 3,63 ng g-1. As
concentrações de mercúrio encontradas nas amostras de arroz variaram na faixa de
2,15 a 7,25 ng g-1. Na segunda parte deste trabalho foi proposto um procedimento
simples, eficiente e reprodutível para a determinação de cádmio em amostras de
arroz por espectrometria de absorção atômica com forno de grafite empregando
modificação química permanente com 400 μg de alumínio. Os experimentos foram
realizados utilizando-se tubo de grafite com plataforma integrada e aquecimento
transversal. Para avaliação da modificação permanente, foram realizados
experimentos na ausência e na presença de modificação química convencional com
paládio e fosfato de amônio. O programa de temperatura do forno de grafite para a
determinação de cádmio foi otimizado para cada tipo de modificador permanente a
fim de avaliar a sensibilidade por meio das curvas de pirólise e atomização. A
temperatura ótima de pirólise e atomização obtidas foram de 400 e 1800 ºC uma vez
que nestas temperaturas os níveis de fundo apresentaram-se baixo, não sendo
observada perda de sensibilidade. A massa característica (mo) e o LD do método
foram 1,32 pg e 1,8 ng g-1, respectivamente, e a vida útil do tubo de grafite foi de
1080 queimas. O desvio padrão relativo foi igual a 1,67 %, demonstrando uma boa
precisão do método. As características analíticas foram comparadas com os
métodos recomendados na literatura. No terceiro trabalho avaliou-se a composição
mineral de Ca, K, Mg, Na, Zn, Fe, Mn, Sr e Zn em arroz integral, parboilizado e
amostras de arroz branco usando ICP OES. O efeito do cozimento no conteúdo
mineral também foi investigado. Todos os dados obtidos foram avaliados utilizando
as técnicas de análise multivariada PCA e HCA. O procedimento avaliado
apresentou uma boa exatidão, evidenciada pela análise de material certificado.
Foram alcançados baixos limites de detecção e quantificação e coeficientes de
correlação maiores que 0,999. / In this work, strategies analytical were developed aiming determination of metallic
species in rice samples using acid digestion procedure in microwave and block
digestor for preparation of the samples. In the first part of this work we developed an
automated system for determination of mercury in rice samples using flow injection
with multiseringa (MSFIA) and detection by cold vapor atomic fluorescence (CVAFS).
Initially, we used a full factorial design for preliminary evaluation of the
variables affecting the system. Then, the planning Doehlert was used in order to
obtain optimal conditions (SnCl2 3% (w / v) in 2% HCl, sample flow 3 mL min-1 and
HNO3 8% (v / v)). The LD and LQ were equal to 0.48 and 1.61 ng g -1, respectively.
The relative standard deviation was less than 2% for a sample with a mercury
concentration of 3.63 ng g-1. The mercury concentrations found in samples of rice in
a range from 2.15 to 7.25 ng g-1. In the second part of this work we propose a simple,
efficient and reproducible for the determination of cadmium in rice samples by atomic
absorption spectrometry with graphite furnace employing permanent chemical
modification with 400 mg of aluminum. The experiments were performed using
graphite tube with integrated platform and cross warming. For evaluation of
permanent modification, experiments were performed in the absence and presence
of conventional chemical modification with palladium and ammonium phosphate. The
temperature program graphite furnace for the determination of cadmium was
optimized for each type of permanent modifier to assess the sensitivity curves by
means of pyrolysis and atomization. The optimum temperature pyrolysis and
atomization obtained were 400 and 1800 °C temperatu res since these background
levels are presented below, with no observed loss of sensitivity. The characteristic
mass (mo) and LD method were 1.32 pg and 1.8 ng g-1 respectively and lifetime of
the graphite tube was 1080 firings. The relative standard deviation was equal to
1.67%, showing a good accuracy of the method. The analytical characteristics were
compared with the methods recommended in the literature. In the third study
evaluated the mineral composition of Ca, K, Mg, Na, Zn, Fe, Mn, Sr and Zn in brown
rice, parboiled and white rice samples using ICP OES. The effect of cooking on the
mineral content was also investigated. All data were evaluated using multivariate
analysis PCA and HCA. The procedure evaluated showed good accuracy, as
evidenced by the analysis of certified material. Were achieved low limits of detection
and quantification and correlation coefficients greater than 0.999.
|
186 |
Otimização de métodos analíticos e caracterização da farinha de trigo refinada: uma contribuição à Tabela Brasileira de Composição de AlimentosAraujo, Rennan Geovanny Oliveira 17 May 2007 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-04-07T17:53:48Z
No. of bitstreams: 1
Tese_de_Doutorado_Rennan_G_O_Araujo.pdf: 2718676 bytes, checksum: 59eab9c3f63867e32dff273384239532 (MD5) / Approved for entry into archive by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-05-10T17:42:10Z (GMT) No. of bitstreams: 1
Tese_de_Doutorado_Rennan_G_O_Araujo.pdf: 2718676 bytes, checksum: 59eab9c3f63867e32dff273384239532 (MD5) / Made available in DSpace on 2016-05-10T17:42:10Z (GMT). No. of bitstreams: 1
Tese_de_Doutorado_Rennan_G_O_Araujo.pdf: 2718676 bytes, checksum: 59eab9c3f63867e32dff273384239532 (MD5) / CNPq e FAPESB / A farinha de trigo é um produto muito importante consumida em muitas partes do
mundo. A determinação de seus constituintes é de interesse tanto nutricional como
toxicológico. No intuito de rastrear nutrientes e contaminantes presentes na
composição mineral da farinha de trigo consumida em cidades brasileiras foi
desenvolvido um estudo de investigação de forma a ampliar dados sobre tal gênero
alimentício. Foram desenvolvidos quatro trabalhos para determinação de metais em
farinha de trigo usando técnicas espectrométricas atômicas. O primeiro trabalho
consistiu na determinação de manganês em amostras coletadas na cidade de
Salvador, Bahia, Brasil - utilizando amostragem suspensão e detecção por
espectrometria de absorção atômica com chama (FAAS). A concentração de
manganês nas amostras variou entre 5,2 ± 0,7 a 7,6 ± 0,5 μg g-1. Os limites de
detecção e de quantificação foram 0,13 e 0,44 μg g-1, respectivamente. A precisão
foi expressa através do desvio padrão relativo (%RSD) foi de 3,5 % (n=10). A
exatidão foi confirmada através de análise de três materiais de referência
certificados de farinha de arroz. O uso da calibração com padrões aquosos facilitou
um procedimento simples e rápido para determinação de manganês em farinha de
trigo. No segundo trabalho, foram comparados dois métodos analíticos para
determinação de cádmio empregando a espectrometria de absorção atômica com
atomização eletrotérmica em forno de grafite (GF AAS) sem a digestão da amostra
de farinha de trigo através da amostragem direta de sólidos (SS) e a amostragem
em suspensão com múltiplas injeções (SlS) como introdução. Após a otimização das
condições usando a mistura paládio e magnésio como modificador químico, a
temperatura de pirólise usada foi de 800 ºC, e 1600 ºC como temperatura de
atomização, sem observação de sinal fundo de absorção. A calibração versus
padrões aquosos foi utilizado para ambos os métodos otimizados. Foram
estabelecidas as figuras de mérito: massa característica 0,6 e 1,0 pg, limite de
detecção (3σ, n = 10) 0,2 e 0,7 ng g-1, limite de quantificação (10σ, n = 10) 0,7 e 2,3
ng g-1 e precisão expressa como desvio padrão relativo (n=5) de 6 – 16% e 9 – 23%
para SS e SlS, respectivamente. As análises de materiais de referência certificados
de farinha de trigo, folhas de maças, farelho de milho e pão confirmaram a exatidão
dos métodos. Seis amostras de farinha de trigo foram analisadas para determinação
de cádmio coletadas em cidades brasileiras, sendo encontrado a concentração
desse elemento variando entre 8,9 ± 0,5 e 13 ± 2 μg kg-1 nas amostras. Aplicou-se
teste t-Student aos resultados obtidos pelo os dois métodos propostos, estando os
dados concordantes para nível de 95% de confiança. O método SS foi escolhido
como método de rotina, devido à sua simplicidade, a velocidade de análise e os
melhores valores de figura de mérito. O terceiro trabalho, a composição mineral da
farinha de trigo consumida no Brasil foi avaliada. Na etapa de amostragem foram
coletadas 54 amostras em 15 cidades, incluindo as principais cidades brasileiras
como: São Paulo, Rio de Janeiro, Salvador, Porto Alegre, Recife e outras. Os
elementos determinados foram: cálcio, cobre, magnésio, manganês, ferro, fósforo,
potássio e zinco. A técnica analítica empregada foi a espectrometria de emissão
óptica com plasma indutivamente acoplado (ICP OES). A validação do método
(incluindo digestão e determinação) foi confirmada usando um material de referência
certificado de farinha de trigo fornecido pelo NIST. Considerando as 54 amostras analisadas, os resultados demonstraram que os macronutrientes: cálcio, magnésio,
potássio e fósforo encontram-se em média de 0,27; 0,35; 1,71 e 1,92 mg g-1, com
variação da concentração de 0,11 – 1,96; 0,19 – 0,51; 0,76 – 3,16 e 0,81 – 7,15 mg
g-1, respectivamente. Os micronutrientes: cobre, ferro, manganês e zinco
encontram-se em média de 1,84; 37,82; 8,25 e 9,41 g g-1, com a variação de
concentração de 1,00 – 2,80; 10,46 – 146,58; 3,89 – 14,74 e 5,07 – 13,93 g g-1,
respectivamente. Os resultados foram avaliados também usando as técnicas de
análise multivariadas: análise de componente principal (PCA) e análise de
agrupamento hierárquico (HCA). Por fim, o quarto trabalho foi desenvolvido para
determinação de Ba, Cr, Rb, Sr, V, Se e Mo empregando a espectrometria de massa
com plasma indutivamente acoplado (ICP-MS) em 25 amostras de farinha de trigo
coletadas em cidades brasileiras. Foi utilizado o procedimento de digestão assistida
por microondas em sistema fechado. A validação do método foi confirmada através
da adição e recuperação para todos analitos e análise de material de referência
certificado de farinha de trigo NIST 1567a para Se, Mo e Rb. Os valores foram
satisfatórios com uso de germano como padrão interno. Apreciando as 25 amostras
analisadas, os resultados demonstraram que concentração variou entre 1,71 – 10,83
µg g-1 para Ba; 0,060 – 0,307 µg g-1 para Cr; 0,77 – 4,23 µg g-1 para Rb; 0,61 – 5,72
µg g-1 para Sr; 0,023 – 0,108 µg g-1 para V; 0,058 – 0,952 µg g-1 para Se e 0,115 –
0,684 µg g-1 para Mo. Os resultados foram avaliados também usando as técnicas de
análise multivariadas: PCA e HCA. / The wheat flour is a very important product consumed in many parts of the world.
The determination of its constituents is of interest both nutritional and toxicological. In
order to trace nutrients and contaminants present in the mineral composition of wheat
flour consumed in Brazilian cities was conducted a research study in order to expand
data on such foodstuff. There have been four works for determination of metals in
wheat flour using atomic spectrometric techniques. The first work was the
determination of manganese in samples collected in the city of Salvador, Bahia,
Brazil - using slurry and detection by flame atomic absorption spectrometry (FAAS).
The concentration of manganese in the samples ranged between 5.2 ± 0.7 a 7.6 ±
0.5 μg g-1. The limits of detection and quantification were 0.13 and 0.44 μg g-1,
respectively. The precision was expressed by the relative standard deviation (RSD%)
was 3.5% (n=10). The accuracy was confirmed through analysis of three rice flour
certified reference materials. The use of calibration standards agaisnt aqueous
facilitated a simple and rapid procedure for determination manganese in wheat flour
samples. In the second work, were compared two methods to cadmium
determination employing graphite furnance atomic absorption spectrometry (GF AAS)
without the digestion of the wheat flour sample, through direct solid sampling (SS)
and slurry with multiple injections(SlS) as form of introduction. After the optimization
of conditions using a mixture of palladium and magnesium as chemical modifier, the
temperature pyrolysis used was 800 º C and 1600 º C as temperature, atomization,
without remark the of background. The calibration against aqueous standards was
used for both methods optimized. The parameter of merit were established:
characteristic mass of 0.6 and 1.0 pg Cd, detection limit (3σ, n = 10) of 0.2 and 0.7
ng g-1, limit of quantification (3σ, n = 10) of 0.7 and 2.3 ng g-1 and precision
expressed as standard deviation relative (n = 5) between 6-16% and 9-23% for SS
and SlS, respectively. The analysis of certified reference materials of wheat flour,
apples leaves, corn brad and brown bread confirmed the accuracy of the methods.
Six samples of wheat flour were collected in Brazilian cities and analyzed for
determination of cadmium. The cadmium concentration found range between 8.9 ±
0.5 and 13 ± 2 μg kg-1 in the samples. It was applied the Student's t-test results
obtained for two methods proposed, and the data agreement on a 95% confidence
level. The SS method was chosen as routine method, because of its simplicity, speed
of analysis and the best values of parameter of merit. The third work, the mineral
composition of wheat flour consumed in Brazil was evaluated. In the sampling step
54 samples were collected in 15 cities, including principal Brazilian cities such as:
São Paulo, Rio de Janeiro, Salvador, Porto Alegre, Recife and others. The elements
determinate were: calcium, copper, magnesium, manganese, iron, phosphorus,
potassium and zinc. The samples were digested using nitric acid and hydrogen
peroxide in open system. The analytical technique employed was Inductively
Coupled Plasma Optical Emission Spectrometry (ICP OES). The method validation
(including digestion and determination) was performed using a certified reference
material of wheat flour furnished by National Institute of Standards & Technology (NIST). Considering the 54 samples analyzed, the results demonstrated that the
macronutrients: calcium, magnesium, potassium and phosphor have average content
of 0.27, 0.35, 1.71 and 1.92 mg g-1, for concentration ranges of 0.11-1,96, 0.19-0.51,
0.76-3.16 and 0.81-7.15 mg g-1, respectively. The micronutrients: copper, iron,
manganese and zinc have average content of 1.84, 37.8, 8.2 and 9.4 μg g-1, for
concentration ranges of 1.00-2.80, 10.5-146.6, 3.9-14.7 and 5.1-13.9 μg g-1,
respectively. The results were also evaluated using the multivariate analysis
techniques: principal component analysis (PCA) and hierarchical cluster analysis
(HCA). Finally, the fourth work was conducted to determination of Ba, Cr, Rb, Sr, V,
Mo and employing inductively coupled plasma mass spectrometry (ICP-MS) in 25
samples of wheat flour collected in Brazilian cities. The procedure assisted by
microwave digestion in closed system was used. The accuracy of the method was
confirmed by the addition and recovery for all analytes and analysis of certified
reference material of wheat flour NIST 1567 for Se, Mo and Rb. The parameter of
merit were satisfactory with used isotope of german (74Ge) as internal standard. The
25 wheat flour samples were analyzed, the results showed concentration ranged
between 1.71 - 10.83 μg g-1 for Ba, 0060 - 0307 μg g-1 for Cr, 0.77 - 4.23 μg g-1 to Rb;
0.61 - 5.72 μg g-1 for Sr; 0.023 – 0.108 μg g-1 to V; 0.058 – 0.952 μg g-1 for Se and
0.115 – 0.684 μg g-1 for Mo. The results were also evaluated using the techniques of
multivariate analysis: PCA and HCA
|
187 |
Decomposição de elastômeros por combustão iniciada por microondas em sistema fechadoMoraes, Diogo Pompéu de 28 July 2006 (has links)
A rapid digestion procedure for further determination of inorganic elements in carbon black-containing elastomers has been developed using sample combustion in closed quartz vessels with oxygen pressure. Microwave radiation was used for the ignition step. Samples containing high levels of carbon black (up to 30%) were digested using the proposed procedure: nitrile-butadiene rubber (NBR) and ethylenepropylene-diene monomer (EPDM). A quartz device was used simultaneously as a sample holder and for the protection of vessel cap. Sample was pressed as pellet
and placed together a small piece of low-ash content paper in the holder. Ammonium nitrate solution (50 ml of 50% m/v) was added to the paper as aid for ignition. The influence of the absorption solution (nitric acid or water) and the necessity of an additional reflux step were evaluated. Determination of Al, Fe, Mn, Sr and Zn was performed by inductively coupled plasma optical emission spectrometry. A reference method (ASTM D 4004-064) based on conventional dry ashing followed by flame atomic absorption spectrometry determination was used for results comparison (Mn and Zn). Results were also compared to those obtained by using wet acid digestion in closed systems. As no certified reference elastomers were available analyte spikes were made for NBR and EPDM digests. Concentrated and diluted (4 mol l-1) nitric
acid, with 5 min for reflux step after the combustion process, gave better recoveries for all analytes (from 97 to 101%). For Al and Mn recoveries were bellow 90% for both open and closed vessels using HNO3 and H2SO4 mixture. For dry ashing
quantitative recoveries were found only for Zn (for Al recovery was 14%). Residual carbon content was bellow 0.5% for the proposed procedure. With the proposed procedure further determination of Al, Mn, Sr and Zn is feasible with only the combustion step but for Fe a reflux with diluted HNO3 was necessary. Then, using the proposed procedure complete sample digestion is obtained is less time than other procedures and no need of concentrated acids was considered necessary. / Neste trabalho foi proposto um procedimento para a decomposição de elastômeros (Etileno-propileno-dieno monômero e borracha do tipo nitrílica) em sistema fechado por combustão iniciada por microondas. Após a decomposição das
amostras foram determinados Al, Fe, Mn, Sr e Zn por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Para Mn e Zn, a metodologia proposta foi comparada com a metodologia oficial ASTM D 4004-064 para a decomposição de elastômeros e posterior determinação por espectrometria de absorção atômica com chama (F AAS).
Os resultados obtidos foram concordantes com a metodologia oficial para a determinação de Mn e Zn. Adicionalmente, ensaios de recuperação foram empregados para Al, Fe, Mn, Sr e Zn para avaliação do método proposto. Além disso, foram estudados dois tipos de solução absorvedora (H2O e HNO3 diluído e concentrado), além da variação do emprego do tempo de aquecimento com microondas (1 min ou 5 min). Entretanto, para se obter recuperações quantitativas
para todos os elementos, em ambas as amostras, é necessário que se utilize HNO3 4 molar ou concentrado como solução absorvedora e uma etapa adicional de refluxo
ao procedimento de combustão. Cabe destacar que outras condições podem ser utilizadas, como por exemplo, HNO3 concentrado sem a etapa adicional de refluxo, entretanto nestas condições as recuperações podem ser quantitativas para todos os elementos com exceção de ferro. Cabe salientar que, o procedimento proposto foi comparado com o procedimento da norma ASTM, onde os valores encontrados para Zn e Mn nas amostras foram concordantes pelas duas técnicas. O teor de carbono residual é baixo e comparável aos do sistema de decomposição por via seca em mufla. Desta forma é possível propor este procedimento para a decomposição de elastômeros do tipo EPDM e NBR, sendo adequado para a posterior determinação de Al, Fe, Mn, Sr e Zn.
|
188 |
Desenvolvimento de métodos espectroanalíticos aplicados à documentoscopia, bens culturais e alimentosBORBA, Flávia de S. L. 31 January 2012 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-03-10T19:22:39Z
No. of bitstreams: 2
tese_gravar_cd.pdf: 9826544 bytes, checksum: b8530b3e8f82a5777705f01c37bdaf7c (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-10T19:22:40Z (GMT). No. of bitstreams: 2
tese_gravar_cd.pdf: 9826544 bytes, checksum: b8530b3e8f82a5777705f01c37bdaf7c (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Previous issue date: 2012 / CNPq / Esta tese é composta por três trabalhos. O primeiro trabalho trata do desenvolvimento de um método analítico não destrutivo para discriminar tintas de canetas azuis do tipo gel (3 marcas), esferográfica (5 marcas) e rollerball (2 marcas). Foram adquiridos espectros de infravermelho médio por reflectância total atenuada de círculos preenchidos com tinta em três tipos de papel A4, sendo duas marcas de papel branco (papel 1 e papel 2) e uma de papel reciclado (papel 3). O algoritmo Kennard-Stone foi utilizado para selecionar os espectros do papel 1 para compor os conjuntos de treinamento, validação e teste. Foram construídos dois modelos com a análise discriminante linear sendo um com as classes compostas pelo tipo e o outro pelas marcas das tintas. Um novo conjunto de teste composto pelos espectros obtidos no papel 2 e 3 foi utilizado para avaliar a influência do papel nas predições dos modelos. Foi obtido 100% de classificação correta em todos os conjuntos de teste, exceto na classificação por marca do papel 3, em que foi obtida 91,3% de classificação correta. Na segunda parte desta tese, a espectroscopia de emissão em plasma induzido por laser (LIBS) foi empregada para analisar sete tijolos antigos e dois fragmentos de pinturas rupestres pertencentes a dois sítios arqueológicos brasileiros, sendo um no estado do Piauí (Toca da Extrema II) e outro no estado do Rio Grande do Norte (Xique-xique). Um instrumento LIBS construído no laboratório (laser Nd:YAG, 1064 nm, 5,2 ns), contendo um policromador echelle, foi empregado para a aquisição dos espectros. Devido à complexidade dos espectros, a análise de componentes principais foi empregada para explorar o conjunto de dados. Os tijolos foram discriminados pelos seus teores de Ti, Zr, Sr e Fe. Estudos preliminares envolvendo uma pintura realizada sobre uma tela de madeira contendo diferentes camadas de material foram realizados para determinar a melhor energia do pulso de laser. Para cada fragmento de pintura, foram realizados 8 pulsos sucessivos em 16 locações diferentes, sendo 8 locações sobre a pintura e 8 sobre o substrato. Neste trabalho foi demonstrado que a utilização de técnicas multivariadas é indispensável devido à grande complexidade dos espectros obtidos durante estudo de profundidade de amostras arqueológicas. Finalmente, a terceira parte desta tese foi dedicada a avaliação do efeito de matriz na determinação da concentração de 20 elementos em suplemento alimentar, por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Foram adquiridas em estabelecimentos comerciais, diferentes marcas de um suplemento alimentar inicialmente designado de “Ração Humana”, cuja composição é variada, mas pode conter cereais, farelos, fibras, farinhas, linhaça, gergelim, extrato de soja, levedo de cerveja, cacau em pó, gelatina em pó e guaraná em pó. Três procedimentos de decomposição foram avaliados: (1) decomposição assistida por microondas, (2) decomposição por combustão na mufla com aditivos e (3) decomposição por combustão na mufla sem aditivos. Os melhores resultados foram obtidos com a digestão por combustão na mufla sem aditivos. Com exceção do Mo, o nível de todos os elementos determinados de forma preliminar estão em concordância com os níveis reportados em produtos destinados à nutrição previamente descritos na literatura.
|
189 |
Zpracování vybraných druhů jedlého hmyzu pro potravinářské účely / Processing of selected species of edible insects for food purposesMasár, Martin January 2021 (has links)
Táto diplomová práca je zameraná na nutričné zhodnotenie vybraných práškov hmyzu zo svrčkov domových, z lariev múčiara obyčajného a potemníka stajňového a jedného potravinového produktu na báze hmyzu, ktorý bol tiež vyvinutý ako jeden z cieľov tejto práce. Okrem základných nutričných analýz boli použité aj ICP-OES pre zistenie obsahu minerálov a GC-FID pre zistenie zloženia mastných kyselín. Tiež bol stanovený obsah hrubej bielkoviny pomocou CHNSO analyzátora a stanovený obsah EAA. Pomocou PCA analýzy sa úspešne podarilo rozlíšiť vzorky jednotlivých hmyzích práškov, ktoré potvrdili rozmanitosť jednotlivých druhov hmyzu a vďaka projekcii do roviny hlavných komponent je možné vidieť, v ktorých nutričných parametroch sa najviac líšia. Bola tiež vykonaná senzorická analýza novo vyvinutého produktu na báze hmyzu s prídavkom prášku z potemníka stajňového v porovnaní s konkurenčnými produktmu. Súčasťou práce je aj rozsiahly spotrebiteľský prieskum na vzorke 2 019 účastníkov, týkajúci sa vnímania entomofágie v Českej republike a na Slovensku, ktorý sa uskutočnil online.
|
190 |
Elementární analýza sýrů s bílou plísní na povrchu / Elemental analysis of cheese with white mold on the surfacePavlechová, Alžbeta January 2018 (has links)
This Master's thesis deals with elementary analysis of cheeses with white mold on the surface. Theoretical part describes general characteristics of cheese, classification of cheeses, their nutritional aspects and characteristics of cheeses with white mold on the surface. Large part is focused on description of mineral substances selected for analysis. At the end of the theoretical part, the Kjeldahl method and emission spectrometry with inductively coupled plasma (ICP-OES) were described. Experimental part deals with preparation of samples, approach of analysis and processing of measured results. Eleven samples of cheeses were used for analysis. These samples were from Czech Republic, France and Slovak Republic. Kjeldahl method was used to determine protein contents and ICP-OES was used for elemental analysis. The results were compared to each other and also with results from other studies. Subsequently, they were statistically processed and evaluated in the final part.
|
Page generated in 0.0406 seconds