• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 833
  • 523
  • 82
  • 45
  • 31
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 17
  • 13
  • 12
  • 11
  • Tagged with
  • 1885
  • 853
  • 745
  • 493
  • 257
  • 239
  • 196
  • 185
  • 175
  • 148
  • 141
  • 134
  • 133
  • 128
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

A study of the effect of low intensity laser therapy on the osseointegration of hydroxyapatite implants

Rajab, Arif Ali January 1999 (has links)
No description available.
412

Early Communicative Behaviors in a Two Year Old Child with a Cochlear Implant in an Auditory-Verbal Program

Okon, Martis R. (Martis Rebecca) 12 1900 (has links)
The communicative interchanges of a congenitally deaf child who received a cochlear implant at 24 months of age were videotaped in fifteen hourly sessions over a nine month period while she participated in auditory-verbal therapy prior to and following implantation. The present study examined selected early communicative behaviors. Using Tait's (1993) protocol for charting communicative adult-child interaction, gestures, eye-gaze, and sound uttered either by the child or an adult during communicative interchanges were transcribed from the videotapes. Results corresponded with Tait's, revealing growth in the child's communicative interaction across sessions. In less than three months following implantation phonemic measures rose dramatically. Almost all phonemic measure correlations were significant, high, and positive.
413

Caractérisation d'un organogel à base d'un dérivé amphiphile de la L-alanine

Motulsky, Aude January 2005 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
414

Dental implant retaining screws: the effect of using gold or titanium on preload

Doolabh, Rajesh 14 February 2011 (has links)
MDent, Faculty of Health Sciences, University of the Witwatersrand / PURPOSE The purpose of this in vitro investigation was to determine the effect of using either gold or titanium retaining screws on preload in the dental implant body-abutment complex. This preload is of vital importance for the long term success of the dental implant complex. Inadequate preload results in either loosening or fracture of the retaining screw, and is the most commonly occurring mechanical complication in implant supported/retained prostheses. Similar complications occur when excessive preload is applied to the retaining screws. These complications can result in unscheduled visits with costly and time consuming repairs for the clinician and patient. Routine maintenance protocols for implant supported prostheses range from biannually to five year visits to the dentist. Maintenance visits involve removal of the prosthesis facilitating cleaning of both the implant and prosthesis and inspection of retaining screws . This study sought to gain insight into changes in preload generation after repeated torque application to gold and titanium screws and to observe whether gold or titanium generated better preload. A maintenance protocol would be suggested if any observable pattern was noted. MATERIALS AND METHODS The test setup consisted of an implant body, a cylindrical transmucosal abutment and the retaining screws (gold or titanium). The implant body was anchored using a load cell. Transmucosal abutments were attached to the implant body using either a gold or titanium v retaining screw. A torque gauge was used to apply torque of 20Ncm, 32Ncm and 40Ncm to the retaining screws. This was undertaken to investigate the effect of gold or titanium on preload generated. The effect of applying torque beyond manufacturers recommended 32Ncm was carried out to see if greater preloads could be achieved. All components were from the Southern Implant system. RESULTS Gold retaining screws were found to achieve consistently higher preload values than titanium retaining screws. Preload values were not significantly different from the first to the tenth torque cycle. Titanium screws showed more consistent preload values, albeit lower than those of gold retaining screws. However due to possible galling of the internal thread of the implant body by titanium screws, gold screws remain the retaining screw of choice. Maintenance protocols suggest replacing retaining screws every 20 years. After ten torque cycles were applied to each screw there was an insignificant change in preload generated in both titanium and gold screws. This study was therefore inconclusive with regards to maintenance protocols. CONCLUSION Within the limitations of this study, gold retaining screws generated better preload than titanium. Torque application beyond manufacturers’ recommendations resulted in a more stable implant complex. Further investigation into repeated torque application to retaining screws is required, to determine ideal maintenance protocols.
415

Análise biomecânica de próteses unitárias sobre implante cone Morse em região pré-maxilar variando-se o tamanho do implante e tipo de ancoragem óssea : estudo pelo método dos elementos finitos 3-D /

Oliveira, Hiskell Francine Fernandes e. January 2017 (has links)
Orientador: Fellippo Ramos Verri / Banca: Karina Helga Turcio de Carvalho / Banca: Joel Ferreira Santiago Junior / Resumo: Análise biomecânica de próteses unitárias sobre implante cone Morse em região pré - maxilar variando - se o tamanho do implante e tipo de ancoragem óssea. Estudo pelo método dos elementos finitos 3 - D . [Dissertação]. Araçatuba: Faculdade de Odontologia da Universidade Estadual Paulista; 2017. Resumo Este trabalho teve como objetivo analisar a distribuição das tensões em próteses unitárias implantossuportadas de cone morse, em região de maxila anterior, variando o tipo de ancoragem óssea em colocação convencional, bicorticalizado e bicorticalizado com levantamento de assoalho nasal, com diferentes comprimento s do implante, sendo eles de 8,5, 10 e 11,5mm e diâmetro de 4,0 mm, através do método dos elemen tos fin itos tridimensionais. F oram simulados 3 modelos tridimensionais maxilares da região anterior envolvendo o elemento 11, com auxílio de programas de criação de modelos a partir de tomografias, o InVesalius (CTI, São Paulo, Brasil) e programas de desen ho assistido, o Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA) e o SolidWorks 2011 (SolidWorks Corp, USA). Os modelos dos blocos ósseos foram reconstruídos a partir da tomografia computadorizada, com a presença de um implante nas dimensões citadas acima, com coroa livres de metal em zircônia e cimentada s. Os modelos 3D foram exportados para o programa de elementos finitos FEMAP v.11 (Siemens Product Lifecycle Management Software Inc.USA) para dis cretização dos modelos, geração da malha de elementos finitos e análise posterior a processamento no programa NEiNastran 11 (Noran Engineering, Inc., USA). Foram aplicadas cargas de 178N, em ângulo de 0º, 30º e 60º, considerando - se o longo eixo do im plante como referência . Os resultados foram visualizados por meio de mapas de deslocamento, tensão de von Mises, tensão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to analyze the distribution of tensions in morse tapper implants supporting single crowns in the anterior region of maxilla, varying the type of bone anchorage in conventional, bicorticalized and bicorticalized placement with nasal floor elevation, and different lengths of implants (8.5, 10 and 11.5mm) with 4.0 mm of diameter, using the 3D finite element analyses. Three 3-dimensional maxillary models of the anterior region including element #11 were simulated using software InVesalius for CT Scan recomposition (CTI, São Paulo, Brazil) and CAD-software Rhinoceros 3D 4.0 (NURBS Modeling For Windows, USA) and SolidWorks 2011 (SolidWorks Corp, USA). The bone block models were reconstructed from the computed tomography, with the presence of an implant in the dimensions mentioned above, with cemented zirconium metal free crowns. The 3D models were exported to the FEMAP v.11 finite element software (Siemens Product Lifecycle Management Software Inc.) for models discretizadion, mesh generation and post-processing analysis after processing progress in the NEiNastran 11 program (Noran Engineering, Inc ., USA). Loads of 178N were applied at angle of 0º, 30º and 60º, considering the implant long axis as reference. The results were visualized by means of displacement maps, von Mises maps, Max Principal maps and microstrain. Analyzing all stress maps, the bicortical models were the ones that showed with better stress and strain distributions, both in the implant a... (Complete abstract click electronic access below) / Mestre
416

Análise das intercorrências e complicações interferentes na instalação e perda primária dos implantes dentais osteointegráveis - um estudo retrospectivo / Analysis of intercurrences and complications interfering in the placement and primary loss of osseointegratable dental implants a retrospective study

Silva, Alessandro Costa da 09 October 2008 (has links)
Intrinsecamente, todo procedimento cirúrgico apresenta um certo índice de intercorrências e/ou complicações associadas. Hemorragias, infecções, parestesias ou disestesias e perda primária dos implantes são algumas das intercorrências e complicações mais comuns relacionadas a procedimentos cirúrgicos para implantodontia. Este estudo avaliou retrospectivamente o índice de intercorrências e complicações após cirurgia para a instalação de implantes dentais osteointegráveis. Foram avaliados, retrospectivamente, 660 prontuários clínicos de pacientes submetidos à instalação de implantes osteointegráveis no período 8 anos atendidos na Área de Cirurgia Buco-Maxilo-Facial da Faculdade de Odontologia de Piracicaba - Unicamp. Os resultados demonstraram que houve um maior índice de intercorrências e complicações quando os pacientes eram atendidos por alunos de especialização (p= 0,015) e quando o exame por imagem realizado era somente a radiografia panorâmica convencional (p= 0,011). Os resultados demonstraram também um maior índice de intercorrências e complicações nos pacientes quando estes eram submetidos a procedimentos cirúrgicos de reconstrução óssea alveolar (p< 0,0001). A presença de infecção pós-operatória influenciou significativamente para o aumento no índice de perda primária de implantes (p< 0,0001). / Intrinsically, every surgical procedure presents a certain rate of associated intercurrences and/or complications. Hemorrhages, infections, paresthesias or dysesthesias and primary loss of implants are some of the most common intercurrences and complications related to surgical procedures in implant dentistry. This study conducted a retrospective evaluation of the rate of intercurrences and complications related to patients submitted to osseointegratable dental implant placement. A retrospective evaluation was made of 660 clinical record charts of patients submitted to osseointegratable dental implants in the period of 8 years, attended in the Oral and Maxillofacial Surgery Department of Piracicaba Dental School - Unicamp. The results showed that there was a higher rate of intercurrences and complications when patients were attended by residents (p= 0.015) and when the panoramic radiograph was the only preoperative image exam requested (p= 0.011). The results also showed a higher rate of intercurrences and complications in patients when they were submitted to surgical procedures of alveolar bone reconstruction (p< 0.0001). The presence of post-operative infection had a significant influence on the increase in the primary loss of implants (p< 0.0001).
417

Avaliação histológica e histomorfométrica do comportamento ósseo em relação à profundidade da linha marginal de cimentação de próteses sobre implantes Cone Morse: estudo experimental em cães / Histologic and histomorphometric evaluation of bone behavior in relation to the depth of the line of marginal cementation on Morse taper implants: experimental study in dogs

Stancari, Fernanda Herrera 18 May 2015 (has links)
A utilização dos implantes cone morse muito favorece a estética peri-implantar e seu uso em conjunto com próteses cimentadas favorece ainda mais a estabilidade do sistema, simplificando também os procedimentos protéticos. O presente estudo histológico e histomorfométrico utilizou os implantes cone morse com o intuito de avaliar o comportamento tecidual com relação à posição da margem da cimentação protética em relação ao tecido ósseo quando se faz o uso próteses cimentadas. Foram utilizados quatro cães, os quais tiveram todos os pré-molares inferiores extraídos numa primeira fase cirúrgica. Após três meses, realizou-se a segunda fase cirúrgica, na qual foi realizada a técnica da carga imediata, com a instalação dos implantes juntamente com os pilares protéticos. Foram instalados vinte e quatro implantes numa profundidade de 3 mm infra óssea e eles foram igualmente divididos entre os grupos Controle e Experimental. Os pilares protéticos utilizados foram do tipo munhão universal e apresentavam diferentes alturas transmucosas iguais a 1.5 mm, 3.5 mm, e 5.5 mm. Isto fez com que a margem da cimentação se posicionasse a 1.5 mm infra óssea, a 0.5 mm supra óssea e a 2.5 mm supra óssea. No grupo Controle, foi realizada a instalação dos implantes e dos pilares protéticos somente. No grupo Experimental, foi realizada a instalação dos implantes, dos pilares protéticos e, sobre estes, foram cimentados cilindros de alumina. Os animais permaneceram sobre controle de placa durante 10 semanas subsequentes a instalação dos implantes, sendo este o tempo final do experimento através da realização da eutanásia. As amostras foram preparadas para análise histológica e avaliação dos tecidos peri-implantares. A região de interesse foi medida através da distância entre a margem do pilar protético e a porção mais coronal da crista óssea peri-implantar. Foram utilizados os testes estatísticos ANOVA a três critérios com medidas repetidas e teste de Tukey com o nível de significância de p < 0.05. Os resultados mostraram que não houve diferenças estatisticamente significantes entre os grupos Controle e Experimental (p = 0.2764) e que os pilares de 1.5 mm mostram menos perda óssea comparada aos outros pilares, considerando que a distância média da remodelação óssea foi menor neste grupo (0.6859 mm) comparada com os pilares de 3.5 mm (1.2917 mm) e 5.5 mm (1.0823 mm). Conclui-se que não há influência da profundidade da margem da cimentação protética no comportamento da crista óssea e que a utilização de diferentes alturas dos pilares protéticos não parece alterar o tecido ósseo marginal ao redor dos implantes Cone Morse. / The use of Morse taper implants has increased because of some positive features. Cemented crowns can be extensively used, taking advantage of the system connection stability, also simplifying the prosthetic procedures. The present histological and histomorphometric study used Morse taper implants with the purpose of evaluating bone behavior with respect to the cementation margin position of the prosthetic crown. Four dogs had all premolars extracted at a first surgical procedure. After three months, there was a second surgical procedure with simultaneous installation of implants and abutments, submitted to immediate load. Twenty four implants were installed 3 mm below the bone level and they were equally divided between Control and Experimental groups. The universal post abutments used had three different transmucosal heights, 1.5 mm, 3.5 mm and 5.5 mm. Thus there were implants with the level of the cementation margin positioned 1.5 mm below the bone level, as well as 0.5 mm and 2.5 mm above the bone level. In the Control group, installation of implants and abutments only was performed. In the Experimental group immediately after the placement of implants and abutments alumina cylinders were cemented. The animals were kept on plaque control for 10 weeks after implant placement and then euthanized. Samples were prepared for histological analysis and evaluation of peri-implant tissues. The region of interest was measured by the distance between the prosthetic margin of the abutment to the most coronal peri-implant bone crest. ANOVA test at three criteria with repeated measures and Tukey test with a significance level of p < 0.05 were applied. The results showed no statistically significant differences between Control and Experimental groups (p = 0.2764). The 1.5 mm abutments presented less bone loss compared to all other abutments tested, because the distance average of bone remodelation was shorter in this group (0.6859 mm) compared to the 3.5 mm abutment (1.2917 mm) and the 5.5 mm one (1.0823 mm). Conclusion: There is no influence of the depth of prosthetic marginal cementation on the behavior of bone crest and the use of different transmucosal heights of abutments does not seem to change the marginal bone surrounding morse taper implants.
418

Avaliação de massa e rugosidade superficial de pastilhas de Ti-6Al-4V com aplicação de nanopartículas de prata submetidos ao teste de escovação / Evaluation of mass and surface roughness of Ti-6Al-4V tablets with silver nanoparticles application submitted to brushing test

Marques, Vinícius Rizzo 09 December 2015 (has links)
Este estudo teve por objetivo avaliar a variação da massa e rugosidade de pastilhas de Ti-6Al-4V com e sem aplicação superficial de nanopartículas de prata coloidal (BSafe®) de dimensões 1,5 cm; 0,5 cm e 0,2 cm, submetidas à teste de escovação e imersão pelo período experimental de 10 anos. No teste de escovação, quinze espécimes de Ti-6Al-4V (TE), quinze com B-Safe® (BE) e quinze de PMMA (PE) como controle foram subdivididos em três condições de escovação: dentifrício comum (DC), dentifrício experimental (DE) e controle com água destilada (H2O) por 200 mil ciclos em máquina de escovação. Os resultados foram submetidos ao teste ANOVA a 2 critérios (condição de escovação e ciclos) e teste de Tukey (&#x3B1;=0,05) para comparações múltiplas. Foi observada variação de massa apenas quando a condição de escovação foi DC nos espécimes do grupo PE e TE. Houve diferença estatisticamente significante nos valores da variação de rugosidade no grupo TE e PE quando a condição de escovação foi DC; no grupo BE, houve diferença quando a condição foi DC e DE, porém em DE houve redução dos valores médios. No teste de imersão, objetivando analisar a ação dos dentifrícios sem o atrito das cerdas, seis espécimes de Ti-6Al-4V (TI) e seis com B-Safe® (BI) foram subdivididos em três condições de imersão: DC, DE e H2O pelo período de 244 horas. Os resultados foram submetidos ao teste t de student pareado. Não foi observada diferença estatística entre as variações de massa e rugosidade de nenhum dos corpos de prova após o teste. Complementar aos ensaios, foi realizado um protocolo de desinfecção com terapia fotodinâmica com azul de metileno pelo período de 4 semanas nos espécimes escovados. Após todos os testes, foi realizada espectrometria de energia dispersiva de raios-X (EDS) para caracterização dos elementos químicos presentes nos espécimes, onde não se observou variações. Os resultados sugerem que o DE é mais indicado para utilização com implantes, enquanto DC apresenta um poder abrasivo capaz de danificar a superfície do Ti-6Al- 4V. Não foi observado nenhum indício de corrosão em nenhum grupo testado. / This study aimed to evaluate the variation of mass and roughness of Ti-6Al-4V tablets with and without superficial application of colloidal silver nanoparticles (BSafe®) with dimensions of 1,5 cm; 0,5 cm and 0,2 cm, submitted to brushing and immersion test for an experimental period of 10 years. For the brushing test, fifteen specimens of Ti-6Al-4V (TE), fifteen with B-Safe® (BE) and fifteen of PMMA (PE) as control were subdivided into three brushing conditions: normal toothpaste (DC), experimental toothpaste (DE) and control with distilled water (H2O) by 200 thousand cycles in brushing machine. The results were submitted to the ANOVA test on 2 criteria (brushing condition and cycles) and the Tukey test ((&#x3B1;= 0,05) for multiple comparisons. Mass variation was observed only when the brushing condition was DC, in PE and TE groups. Statistically significant difference was observed in the values of roughness variation on TE and PE group when the brushing condition was DC; in the BE group, there was difference when the condition was DC and DE, however in DE there was reduction of the average values. In the immersion test, aiming to analyze the action of toothpastes without the friction of the bristles, six specimens of Ti-6Al-4V (TI) and six with B-Safe® (BI) were subdivided into three immersion conditions: DC, DE and H2O for a period of 244 hours. The results were submitted to paired student t-test. No statistical difference was observed between mass and roughness variation for any of the specimens after the test. Additional to the tests, a disinfection protocol with photodynamic therapy with methylene blue was performed for a 4-week period on the brushed specimens. After all tests, Energydispersive X-ray Spectroscopy (EDS) was performed for characterization of the chemical elements present in the specimens, in which no variations were observed. The results suggest that DE is most suitable for use with implants, while DC has a higher abrasive power capable of damaging the Ti-6Al-4V surface. There was no evidence of corrosion in any tested group.
419

Análise clínica e de marcadores biológicos no fluido do sulco peri-implantar correlacionando-os à mucosa ceratinizada ao redor de implantes dentários / Clinical and biological markers analysis in peri-implant fluid and correlation with the keratinized mucosa around dental implants

Souza, Andréia Pereira de 10 February 2017 (has links)
Uma faixa adequada de mucosa ceratinizada (MC) é importante para garantir condições mínimas necessárias para o estabelecimento da homeostasia do periodonto de proteção. Frente à infecção bacteriana, os tecidos periodontais e peri-implantares desenvolvem uma resposta imune inflamatória local, resultando na produção e liberação de diversos mediadores inflamatórios que podem ser encontrados no fluido do sulco gengival e peri-implantar. Entretanto, é escassa a literatura acerca dos níveis desses mediadores em sítios peri-implantares considerando a faixa de MC. Assim, o objetivo deste trabalho foi avaliar a associação entre a quantidade e qualidade da MC peri-implantar e parâmetros clínicos e a qualidade da resposta imune através da análise da concentração de mediadores inflamatórios (IL-1, IL-4, IL-6, IL-8, MIP-1, TNF- e VEGF) presentes no fluido peri-implantar humano antes (T1) e depois (T2) da raspagem subgengival, através de imunoensaio. Parâmetros clínicos avaliaram índice de placa (IP), supuração a sondagem (S), profundidade de sondagem (mesial-PSM, centro-PSC e distal-PSD), índice de sangramento (mesial-ISM, centro-ISC e distal-ISD), nível de inserção relativo (NIR), largura (LMC) e espessura (EMC) da MC na face vestibular. Amostras de fluido sulcular foram coletadas e analisadas. Os implantes foram divididos em grupos de acordo com a faixa de MC (G12mm e G2>2mm) e espessura de MC (GA11mm e GB1>1mm; GA21,5mm e GB2>1,5mm). Foram avaliados 20 pacientes (11 homens e 9 mulheres) com idade entre 40 e 80 anos (53,45±10,32), que apresentaram 42 implantes (G1=25 e G2=17). Os resultados clínicos demonstraram diferença estatística significativa apenas entre T1 e T2 dentro do G1 para IP (T1=56% e T2=16%) e ISM (T1=68% e T2=40%). Foi observada diferença estatística entre G1 e G2 apenas para IL-1 em T2 (G1=9,77pg/ml±12,44 e G2=30,13pg/ml±32,29). Intra-grupos, todas as citocinas aumentaram significativamente, mas apenas no G2, demonstrando diferença de reatividade entre grupos. Quanto à espessura da MC (GA1=6 e GB1=36), resultados clínicos revelaram diferença inter-grupos para ISC em T2 (GA1=16,67% e GB1=61,11%) e intra-grupos para IP no GB1 (T1=52,78% e T2=27,78%). Houve aumento significativo no GB1 para todas as citocinas, exceto VEGF, assim como para IL-1 no GA1. Quando a amostra foi redistribuída em GA2=24 e GB2=18, os resultados clínicos indicaram diferença estatística inter-grupos para PSC em T2 (GA2=2,58mm±1,06 e GB2=3,11mm±1,02) e intra-grupos para IP (T1=62,5% e T2=20,83%) e PSC (T1=2,92mm±1,18 e T2=2,58mm±1,06) no GA2 e para ISM (T1=55,56% e T2=27,78%) no GB2. Intra-grupos observou-se aumento significativo para todas as citocinas no GA2 exceto VEGF, assim como IL-8 no GB2. Conclui-se que as diferenças clínicas apresentadas tenderam a evidenciar a importância da MC principalmente após o preparo inicial e, além disso, uma faixa de MC maior que 2mm influenciou os níveis dos mediadores inflamatórios avaliados após a raspagem subgengival. Adicionalmente, a falta de diferença estatística significativa na comparação entre grupos com diferentes espessuras de MC, bem como tal diferença ora no grupo espesso ora no grupo fino quando se adotam diferentes valores de corte (1mm ou 1,5mm respectivamente), demonstra resultados inconclusivos, ressaltando a importância de novas pesquisas para responder esta questão. / An adequate keratinized mucosa (KM) width is important to ensure minimal conditions necessary to establish protect periodontium homeostasis. When a bacterial infection occurs, periodontal and peri-implant tissues develop a local inflammatory immune response that results in production and release of several inflammatory mediators that may be found in gingival crevicular and in peri-implant fluids. However, there is a lack of literature concerning about the levels of these mediators in peri-implant sites considering KM width. The aim of this study was to evaluate the association between KM peri-implant quantity and quality and clinical parameters and immune response quality by analyzing the inflammatory mediators concentration (IL-1, IL-4, IL-6, IL-8, MIP-1, TNF- and VEGF) present in human peri-implant fluid before (T1) and after (T2) subgingival scaling, by immunoassay. Clinical parameters evaluated plate index (PI), probing suppuration (S), probing depth (mesial-PDM, center-PDC and distal-PDD), bleeding index (mesial-BIM, center-BIC and distal-BID), relative attachment level (RAL), keratinized mucosa width (KMW) and thickness (KMT) on the buccal face. Sulcular fluid samples were collected and analyzed. The implants were divided in groups according KM width (G12mm and G2>2mm) and KM thickness (GA11mm and GB1>1mm, GA21,5mm and GB2>1,5mm). Twenty patients (11 men and 9 women) aged 40 to 80 years (53,45±10,32) were evaluated, with 42 implants (G1=25 and G2=17). Clinical results showed a significant statistical difference only between T1 and T2 within G1 for PI (T1=56% and T2=16%) and BIM (T1=68% and T2=40%). Statistical difference was observed between G1 and G2 only for IL-1 in T2 (G1=9,77pg/ml±12,44 and G2=30,13pg/ml±32,29). Intra-groups, all cytokines increased significantly, but only in G2, showing reactivity difference between groups. As to KM thickness (GA1=6 and GB1=36), clinical results revealed intergroup differences for BIC in T2 (GA1=16,67% and GB1=61,11%) and intra-groups for PI in GB1 (T1=52,78% and T2=27,78%). There was a significant increase in GB1 for all cytokines except VEGF, as well as for IL-1 in GA1. When the sample was redistributed in GA2=24 and GB2=18, clinical results indicated statistical inter-group differences for PDC in T2 (GA2=2,58mm±1,06 and GB2=3,11mm±1,02) and intra-groups for PI (T1=62,5% and T2=20,83%) and PDC (T1=2,92mm±1,18 and T2=2,58mm±1,06) in GA2 and for BIM (T1=55,56% and T2=27,78%) in GB2. Intra-groups were observed significantly increase for all cytokines in GA2 except VEGF, as well as IL-8 in GB2. Concluded that clinical differences presented tended to show the KM importance principally after the initial preparation and, in addition, KM width greater than 2mm influenced the inflammatory mediators levels evaluated after subgingival scaling. Additionally, the absence of significant statistic difference between groups when comparing the keratinized mucosa thickness, as well as this difference sometimes in the thick group or in the thin group when different court values was adopted (1mm or 1,5mm respectively), show inconclusive results, emphasizing the importance of new research that may answer this question.
420

Avaliação da resistência à flexão de mini-implantes desenvolvidos para ancoragem esquelética do aparelho de Herbst - Estudo em Minipig br1 / Flexure resistance evaluation of mini implants prototypes developed for Herbst appliance anchorage Study in Minipig br1

Batista, Klaus Barretto dos Santos Lopes 23 April 2010 (has links)
Um efeito colateral indesejável do uso do aparelho de Herbst é a vestibularização excessiva dos incisivos inferiores que pode estar relacionada à retração gengival, à perda óssea marginal e à reabsorção radicular. A ancoragem esquelética do aparelho de Herbst poderia evitar estes problemas. O objetivo do presente estudo foi o de avaliar, em Minipigs br1, a resistência à flexão de protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst, comparar a resistência dos protótipos entre as duas regiões escolhidas para inserção e avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Após o cálculo do tamanho da amostra, 13 protótipos de mini-implantes foram colocados nas regiões posterior da maxila e anterior da mandíbula de três Minipigs br1, após terem sido mortos. Corpos de prova contendo os protótipos de mini-implantes inseridos em osso foram submetidos a uma força de flexão por engastamento simples utilizandose uma máquina universal de ensaios mecânicos Instron, calculando-se a média e o desvio padrão para cada região. Com o objetivo de comparar a resistência dos protótipos entre as regiões de inserção foi utilizado o Teste t de Student para duas amostras não pareadas. O teste de hipótese foi realizado para cada região para avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Para fins de comparação foram consideradas forças ortopédicas acima de 1,0 kgf. O nível de significância adotado foi P < 0,05. Os protótipos de miniimplantes apresentaram resistência à força de flexão de 13,86 kgf (DP = 2,3) para a região posterior da maxila e 20,55 kgf (DP = 5,2) para a região anterior da mandíbula. Houve diferença estatisticamente significativa entre as duas regiões com relação à força de resistência dos mini-implantes (P = 0,015), sendo que a resistência maior foi na região anterior da mandíbula. A hipótese de que os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas foi confirmada para as regiões posterior da maxila e anterior da mandíbula. Os autores concluíram que, em Minipigs br1, os protótipos de mini-implantes desenvolvidos para a ancoragem do aparelho de Herbst foram capazes de resistir a forças entre 13,86 e 20,55 kgf, sendo estatisticamente mais resistentes na região anterior da mandíbula e capazes de suportar forças ortopédicas. / An undesirable tooth movement resulting from use of the Herbst appliance is the excessive proclination of the anterior mandibular teeth, which is commonly associated with gingival recession, marginal bone loss, and root resorption. Skeletal anchorage of the Herbst appliance could prevent these problems. The present study was designed to evaluate, in Minipigs br1, the flexure resistance of prototype miniimplants developed for Herbst appliance anchorage, to compare the prototype resistance between the regions in which the mini-implants were placed, and to test the hypothesis that these mini-implant prototypes can withstand orthopedic forces. After calculation of sample size, 13 mini-implant prototypes (2 mm in diameter x 10 mm long) were inserted in the posterior region of the maxilla and the anterior region of the mandible, in three recently killed minipigs. The specimens were submitted to a single cantilever flexure test using an Instron testing machine. Mean and standard deviation were calculated for each region. To compare the resistance of the prototypes between the sites of mini-implant insertion, a 2-Sample Students t test was calculated. The test was carried out individually for each region, to evaluate if the prototype mini-implants developed for Herbst appliance anchorage could withstand orthopedic forces. Orthopedic forces above 1.0 kgf were considered. The level of significance was set at P < 0.05. The prototype mini-implant showed a flexure strength of 13.86 kgf (SD = 2.3) for the posterior region of the maxilla, and 20.55 kgf (SD = 5.2) for the anterior region of the mandible. A significant statistically difference was found in the resistance of the prototypes between the two regions (P = 0.015). The hypothesis that the prototype mini-implants can withstand orthopedic forces was confirmed. The authors concluded that, in Minipigs br1, the prototype mini-implants developed for Herbst appliance anchorage could resist forces from 13.86 to 20.55 kgf, were statistically more resistant in the anterior region of the mandible, and were capable of withstanding orthopedic forces.

Page generated in 0.3701 seconds