• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 453
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 467
  • 169
  • 133
  • 82
  • 79
  • 72
  • 65
  • 52
  • 52
  • 49
  • 48
  • 46
  • 44
  • 43
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

Preenchimento e iluminação interativa de modelos 2.5 D

Marques, Bruno Augusto Dorta January 2014 (has links)
Orientador: Prof. Dr. João Paulo Gois / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Ciência da Computação, 2015. / Os avanços recentes para a criação de desenhos animados têm incorporado características que fazem alusão a profundidade e orientação tanto de efeitos de iluminação e sombreamento, como também a simulação de transformações geométricas 3D. Esses recursos melhoram a percepção visual de modelos cartoons e permitem a utilização de efeitos distintos e únicos. Um avanço que ganhou atenção nos últimos anos é o Modelo 2.5D, que simula transformações 3D a partir de um conjunto de imagens vetoriais 2D. Com isso, é criada não somente a percepção de orientação 3D, mas também a automatização do processo de criação de quadros intermediários (in-betweening) em uma animação. Entretanto, as técnicas atuais de modelagem 2.5D não permitem o uso de efeitos interativos de iluminação e preenchimento. Neste trabalho, é apresentado uma resolução ao problema de aplicar efeitos de iluminação em modelos 2.5D. A técnica proposta procura explorar, de forma inédita, a flexibilidade da GPU para inferir relevo e simular transformações 3D nos efeitos de preenchimento e iluminação de modelos 2D em tempo real. Demonstramos a aplicação de diversos efeitos, entre eles Phong shading, Cartoon shading, environment mapping, simulação de pelo (fur shading), mapeamento de texturas estáticas e dinâmicas e hatching shading. / Recent advances for designing and animating cartoons have incorporated depth and orientation cues such as shading and lighting effects, as well as the simulation of 3D geometrical transformations. These features improve the visual perception of cartoon models while increase the artists flexibility to achieve distinctive design styles. A recent advance that has gained attention in the last years is the 2.5D modeling, which simulates 3D transformations from a set of 2D vector arts. Therefore it creates not only the perception of animated 3D orientation, but also automatizes the inbetweening process. However, current 2.5D modeling techniques do not allow the use of interactive shading effects. In this work we approach the problem of delivering interactive 3D shading effects to 2.5D modeling. Our technique relies on the graphics pipeline to infer relief and to simulate the 3D transformations of the shading effect inside the 2D models in real-time. We demonstrate the application on Phong, Gooch and cel shadings, as well as environment mapping, fur simulation, animated texture mapping and (object-space and screen-space) texture hatchings.
352

ANÁLISE DA DISPONIBILIDADE DE ILUMINAÇÃO NATURAL E ARTIFICIAL EM SALAS DE AULA DE INSTITUIÇÃO PÚBLICA DE ENSINO SUPERIOR / ANALYSIS OF AVAILABILITY OF NATURAL AND ARTIFICIAL LIGHTING IN CLASSROOMS IN PUBLIC INSTITUTION OF HIGHER EDUCATION

Mansilha, Raquel Brandão 20 June 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The classrooms are the more permanent environments at schools; therefore their thermal, visual and acoustic characteristics must be carefully considered. Visual comfort can be achieved only with daylighting; artificial lighting is necessary when the daylighting is insufficient. The artificial lighting is responsible for high energy consumption in buildings. According to Klüsener (2009), who analysed a building of UFSM in accordance with Brazilian energy efficiency standards (RTQ-C), the artificial lighting systems reached the level E (on a A-E scale). In general, simple actions could be improving the energy efficiency of the building lighting system. Considering that the university buildings have a similar performance, the adaptation of lighting systems is important for low-energy consumption. This study aims to define classrooms guidelines for visual comfort in accordance with illuminance levels available and their distribution on the work surface where tasks are performed, as well as the energy efficiency of the classrooms lighting systems. The classrooms were selected to represent the existing universe buildings. The classrooms were characterized with regard to dimensions, surface light reflections, opening systems, solar orientation, sun shading systems, external obstructions and artificial electrical lighting systems. The illuminance levels were measured in two classrooms simultaneously with Instrutherm luximeters, model LDR 225. The measurements were in accordance with the Brazilian standards (NBR 15215) and were carried out at six points on an orthogonal grid. A comparative analysis was made for the classrooms that were simultaneously measured. Additionally the partial RTQ-C lighting criteria were applied on the classrooms lighting systems and the theoretical external illuminance levels were calculated in order to generate the daylight factor (DF). The results pointed that the internal daylight distribution is affected by external obstructions that reduce the portion of visible sky and these are not considered in the windows design. For simultaneous daylighting and artificial lighting, the illuminance levels are excessive and poorly distributed; consequently they cause high energy consumption. The existence of unnecessary sun shading systems, for southern solar orientations and for windows with complete sky obstructions, contributes for the insufficient classrooms illuminance levels. The RTQ-C criteria analysis point levels E and C for the classrooms. In general, the DF do not correspond to expected values indicated by international recommendations. / As salas de aula, por serem ambientes de maior permanência dos alunos, devem possuir condições de conforto térmico, visual e acústico adequadas. O conforto visual pode ser obtido com a iluminação natural ou com auxilio da artificial quando a natural não é suficiente. Quando se utiliza a iluminação artificial, existe a preocupação com o consumo energético da edificação. Segundo estudos realizados por Klüsener (2009), que aplicou o Regulamento Técnico da Qualidade para Etiquetagem do Nível de Eficiência Energética de Edifícios (RTQ-C) em uma edificação do campus da UFSM em Camobi, o sistema de iluminação é de baixa eficiência energética, tendo atingido o nível E. No entanto, segundo o mesmo estudo, existe um potencial para a melhoria da eficiência energética a partir de ações simples. Partindo-se do pressuposto que as outras edificações da universidade possuem um desempenho semelhante, percebe-se a importância de adequar os seus sistemas de iluminação a fim de reduzir o consumo de energia. Esse trabalho tem como objetivo apontar diretrizes que visem o conforto visual no que diz respeito aos níveis de iluminância disponíveis e sua distribuição no ambiente, bem como à eficiência energética de sistemas de iluminação de salas de aula. Para isso, foram selecionadas salas de aula que fossem representativas do universo existente no campus. Após, foram feitos os levantamentos de suas características físicas (dimensões, cores das superfícies, tipos de aberturas, orientação solar, tipos de proteções solares, presença de obstruções externas, tipos e distribuição de luminárias e lâmpadas) e foram realizadas medições in loco com luxímetros digitais da marca Instrutherm, modelo LDR 225 e segundo recomendações da NBR 15215 (ABNT, 2005d). Também foi feita uma análise parcial segundo os Requisitos Técnicos da Qualidade para o Nível de Eficiência Energética de Edifícios Comerciais, de Serviços e Públicos (RTQ-C) e uma análise comparativa entre os níveis de iluminância medidos e os coeficientes de contribuição de iluminação natural (CIN) estimados. Com os resultados obtidos, verificou-se que a distribuição da iluminação natural é afetada por condições do entorno que causam obstruções do céu visível, não sendo consideradas no projeto das aberturas. Nas medições com iluminação natural mais artificial, os níveis são excessivos e mal distribuídos, causando consumo desnecessário de energia. As proteções solares presentes nas orientações a norte desconsideram as condições do entorno. A avaliação parcial através da aplicação dos requisitos específicos do RTQ-C para os sistemas de iluminação resultou em nível E para as salas do CE e em nível C para as outras. Os CIN calculados em grande parte do tempo não corresponderam aos valores teóricos esperados para salas de aula, conforme literatura.
353

Desempenho termoenergético de habitação de interesse social

Rios, Gisele Auxiliadora de Almeida [UNESP] 06 February 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-06. Added 1 bitstream(s) on 2015-06-18T12:48:49Z : No. of bitstreams: 1 000829876.pdf: 3780639 bytes, checksum: 87fdda098e7d088f6a27c1796e19b655 (MD5) / Ações de eficiência energética em edificações exigem análise interdisciplinar, capaz de contemplar a complexidade expressa pelas relações de produção do ambiente construído e habitabilidade. O objetivo geral desta pesquisa foi analisar o impacto da aplicação de estratégias bioclimáticas, na eficiência termoenergética de Habitações de Interesse Social (HIS). À partir de um objeto de estudo (HIS) localizado em Cuiabá-MT, as etapas metodológicas compreenderam a avaliação de desempenho térmico e de eficiência energética de três modelos: HIS padrão (HISp) e duas propostas mais eficientes denominados HISeT (com pintura de cor branca na cobertura) e HISeTPJ (com pintura de cor branca na cobertura e nas paredes externas, com alteração das janelas). Por meio de simulação computacional utilizando o EnergyPlus, obteve-se a projeção dos consumos de referência para 13.437 habitações construídas pelo Programa Minha Casa Minha Vida, em Cuiabá-Várzea Grande (período 2009-2013). Os resultados demonstram que o modelo HISeTPJ apresentou melhor desempenho termoenergético, possibilitando uma economia de energia equivalente ao atendimento de mais de 1.000UC, pelo período de um ano. Uma das contribuições deste trabalho foi apresentar uma sistemática para determinação das correlações entre as variações das temperaturas internas e dos consumos de energia elétrica de referência, em função de intervenções na envoltória. Verificou-se a redução de 10,85kWh e de 10,95kWh nos consumos de energia elétrica das HISeT e HISeTPJ, quando ocorrer a redução de 1°C na temperatura interna das mesmas. Este estudo de intervenções na envoltória constitui-se proposta inovadora e com viabilidade econômica demonstrada por meio de Relação Custo-Benefício de 0,38. Evidencia-se a importância de estudos interdisciplinares para definição de políticas públicas para eficiência energética e habitacionais / Energy efficiency actions require interdisciplinary analysis, able to contemplate the complexity expressed by environmental production relations built and habitability. The general purpose of this research was to analyze the impact of the application of bioclimatic strategies in thermoenergy efficiency of social housing (HIS). The research adopted a social housing (HIS) located in Cuiabá / MT as object of study, the methodological steps involved the evaluation of thermal performance and energy efficiency based on the Brazilian normative of three models: standard HIS (HISp), and two more efficient scenarios denominated HISeT (with thermal ink painting on the cover) and HISeTPJ (with paint on the cover and external walls, and windows changed). Through computacional simulation using the EnergyPlus, was obtained projection of the reference consumptions for 13,437 housing built by Minha Casa Minha Vida, in Cuiabá-Várzea Grande (2009-2013). The results show that the model presented better HISeTPJ thermoenergetic performance, enabling energy savings equivalent service over 1.000UC for a period of one year. One of the contributions of this work was to present a system for determining the correlations between changes in internal temperatures and electric power reference consumption, due to interventions in the envelope. It was found a reduction 10,95kWh and 10,85kWh on the electric power consumptions of HISeT and HISeTPJ, when it occurs a 1 ° C decrease in internal temperature of the same. This study interventions in the envelope constitutes innovative proposal and economic viability demonstrated through Cost-Benefit 0.38. It ́s evident the importance of interdisciplinary studies for definition of public policies for energy efficiency and housing
354

Princípios bioclimáticos e princípios de arquitetura moderna - evidências no edifício hospitalar

Mascarello, Vera Lucia Dutra January 2005 (has links)
O edifício hospitalar é um tipo arquitetônico funcionalmente complexo que, segundo se observa, sofreu substanciais alterações no decorrer dos tempos, passando de pavilhonar a monobloco vertical. Esse estudo apresenta uma visão sobre a transformação tipológica do edifício hospitalar, identificando exemplos que apresentam qualidades espaciais de conforto nas unidades de internação e correlacionando princípios corbusianos de projeto e estratégias bioclimáticas. A arquitetura bioclimática explora os benefícios do clima, com soluções integradas para o conforto ambiental como princípio de projeto. O estudo relaciona as variáveis que afetam o conforto ambiental numa internação hospitalar, onde as premências de qualidade de vida são fundamentais para o pronto restabelecimento dos pacientes, uma vez que abrigam pessoas fragilizadas e com alto nível de estresse. Ao longo da revisão bibliográfica, constata-se que o edifício hospitalar concebido durante a arquitetura moderna beneficia soluções de uma arquitetura adaptada ao meio ambiente.O presente trabalho tem como objetivo analisar as relações da arquitetura bioclimática com os fatores climáticos, o conforto do ser humano e as soluções de arquitetura no contexto do ambiente hospitalar, projetado e construído a partir dos princípios corbusianos. Foi realizado um estudo de caso no Hospital Fêmina de Porto Alegre, por se tratar de um exemplo de arquitetura moderna bioclimática. Os espaços estudados são os quartos das unidades de internação e os elementos de arquitetura moderna contemplados no edifício. Os critérios de avaliação no estudo de caso são: medições de temperatura, iluminação natural e realização de entrevistas e questionários aos usuários, combinados com as análises dos princípios de projeto da arquitetura moderna. As interpretações dos resultados do estudo de caso e análises forneceram subsídios para a discussão das hipóteses levantadas e a elaboração das recomendações de projeto para o conforto ambiental nas internações hospitalares.
355

Eficiência energética em instalações residenciais considerando o novo ambiente de medição de consumo /

León, María Fernanda Trujillo. January 2016 (has links)
Orientador: Oscar Armando Maldonado Astorga / Banca: Durval Luiz Silva Ricciulli / Banca: Pedro da Costa Junior / Resumo: O uso de novas tecnologias em equipamentos e dispositivos de consumo de energia elétrica, vem sendo uma ferramenta cada vez mais utilizada para aumentar a eficiência energética na geração, transporte e distribuição de energia. Mesmo com a crise econômica dos últimos anos, a demanda de energia elétrica tem apresentado um crescimento constante em alguns setores da distribuição, principalmente no consumo de instalações residenciais. Neste tipo de instalação, a introdução de tecnologia LED no sistema de iluminação vem crescendo de forma sistêmica resultando em economia para o consumidor que paga a energia consumida em kWh, sem preocupação com aspectos importantes que o consumidor industrial enfrenta como o baixo fator de potência e a distorção harmônica presente na instalação. Este quadro tende rapidamente a mudar com a instalação, nas residências, dos novos medidores digitais pelas distribuidoras, capazes de medir estes tipos de parâmetros. Atualmente, quando vista do lado do sistema de geração, a economia do consumidor em kWh pode não representar uma economia na geração de energia pois, por tratar-se de cargas não lineares, a relação entre o consumo na instalação e a energia necessária que precisa ser gerada nas Usinas para o seu atendimento, medido em kVA, pode não apresentar a mesma vantagem ou mesmo ser uma desvantagem para o sistema elétrico. Este trabalho tem por objetivo apresentar uma análise da utilização de tecnologia LED na iluminação em instalações residenciais, lev... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of new technologies in equipments and power consumption devices, it has been a tool to increase energy efficiency in the generation, transmission, and distribution of energy. Even with the economic crisis of recent years, electricity demand has shown a steady growth in some distribution sectors, especially in the consumer residential. In this type of plant facilities, the use of LED technology in lighting grows systemically resulting in the economy for the residential consumer who pays per kWh, without regard to important aspects that industrial consumers face as a low power factor and harmonic distortion present in the installation. This frame quickly tends to change with home electrical circuits, new digital meters by distributors, capable of measuring such parameters. Currently, from the viewpoint of the power generation system, the consumer economy in kWh may not represent savings in energy production. This assumption is valid because, as it is in non-linear loads the ratio between consumption in the installation and the required power must be provided in plants for your service, measured in kVA, can not present the same advantage or even be a disadvantage to the electrical system. This study aims to present an analysis of the use of LED technology in lighting in residential systems, considering the non-linearity of this new technology and the subsequent introduction in the installation, the increase in electrical losses this may entail. For this purpose, an experimental setup was performed using some of the most common appliances in residential appliances. These devices operate in conjunction with the lighting system. Thus, the outcomes of the different analyses led to considerations for the consumer and the certification agency. The Brazilian utilities are deploying a new digital measurement scenario, and the service clients must observe ... (Complete abstract click electroni access below) / Mestre
356

Análise de técnicas de normalização aplicadas ao reconhecimento facial

Andrezza, Igor Lucena Peixoto 27 February 2015 (has links)
Submitted by Viviane Lima da Cunha (viviane@biblioteca.ufpb.br) on 2016-02-18T10:52:41Z No. of bitstreams: 1 arquivototal.pdf: 2258673 bytes, checksum: 21b44b2c7c089c792e07c8e4e298daf6 (MD5) / Made available in DSpace on 2016-02-18T10:52:41Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2258673 bytes, checksum: 21b44b2c7c089c792e07c8e4e298daf6 (MD5) Previous issue date: 2015-02-27 / Biometrics offers a reliable authentication mechanism that identifies the users through their physical and behavioral characteristics. The problem of face recognition is not trivial because there are many factors that affect the face detection and recognition, as for example, lighting, face position, hair, beard, etc. This work proposes to analyze the effects of geometric and lighting normalization on face recognition techniques, aiming to adapt them to uncontrolled environments. The results show that the utilization of background information in the normalization process increases the face recognition error rates and this happens in many papers in the literature. The lighting and geometric normalization methods, when performed with precise points of the eyes centers, effectively help in face recognition. / A biometria oferece um mecanismo de autenticação confiável, que identifica os usuários por intermédio de suas características físicas e comportamentais. O problema do reconhecimento facial não é trivial, pois existem muitos fatores que influenciam na detecção e no reconhecimento de face como, por exemplo, a iluminação, a posição da face, cabelo, barba, etc. Este trabalho se propõe a analisar os efeitos de técnicas de normalização geométrica e de iluminação sobre métodos de reconhecimento de face, visando adequar esses métodos para ambientes não controlados. Os resultados mostram que a presença do plano de fundo no processo de normalização contribui para aumentar as taxas de erro no reconhecimento de face, fato que ocorre em vários trabalhos presentes na literatura. Nesta dissertação, verificou-se que a aplicação de técnicas de normalização de iluminação e normalização geométrica, quando realizadas com pontos precisos dos centros dos olhos, efetivamente ajuda na tarefa de reconhecimento facial.
357

Desempenho de poedeiras em diferentes programas de luz ao início da postura / Performance of layers in different lighting programs in the onset of lay

Yuri, Flavio Manabu 01 March 2013 (has links)
Made available in DSpace on 2016-12-08T16:24:18Z (GMT). No. of bitstreams: 1 PGCA14MA139.pdf: 23015 bytes, checksum: 79359edb3078879f5ca9aa0338da2c45 (MD5) Previous issue date: 2013-03-01 / With the objective of evaluate the effect of continuous and intermittent lighting programs on the production and quality egg of laying hens in the early lay pullets rearing in open poultry house, a trial was conducted at Aviculture Section of Santa Catarina State University, Lages, SC, Brazil. Were used 420 laying hens with 21 weeks during seven periods of 28 days, they were submitted to three different lighting programs in a completely randomized design with 10 replications. The continuous program with 16 hour photoperiod (daylight + artificial light) and escotoperiod eight hours. The intermitente lighting program of 30 minutes had two photophases of 30 min between natural light and main night eight hours and two escotofases and intermitente lighting of 15 minutes, this program is similar to the previous program, with two photophases 15 min between natural light, a main night eight hours and two escotofases. The avaliation was based on the feed intake (g/bird/day), egg production (%/bird/day), egg weight (g), feed conversion (g/g), egg mass (g), specific gravity (g/cm³), albumen height (mm), Haugh unit, egg componente yield (%), organ index (%) and the means compared by Tukey test (5%). The results presented for feed conversion, specific gravity, weight of fresh egg and stored for 14 and 28 days, egg yield componentes and organs index showed no difference (P>0.05). The intermitente lighting programs 30 minutes and 15 minutes showed significant differences (P<0.05) for feed intake in the second, sixth and seventh trial period, but no significant differences (P>0.05) in egg production. The egg weight, egg mass, showed no significant difference (P>0.05) as well as albumen height and Haugh unit showed no significant difference (P>0.05) for continuous and intermitente lighting programs 30 min and 15 min. Intermittent lighting programs applied in laying hens in the early lay pullets rearing in open poultry house not adversely affect the production performance, egg quality and internal organs of birds, as well as shorten the use of artificial lighting, reducing energy consumption / Com o objetivo de avaliar o efeito de programas de iluminação contínuo e intermitentes sobre produção e qualidade de ovos de poedeiras comerciais semipesadas em início de postura criadas em galpão aberto, realizou-se um trabalho no Setor de Avicultura da Universidade do Estado de Santa Catarina, Lages - SC. Utilizou-se 420 galinhas de 21 semanas de idade durante sete períodos de 28 dias, as quais foram submetidas a três diferentes programas de iluminação em um delineamento inteiramente ao acaso com 10 repetições. O programa contínuo contou com fotoperíodo de 16 horas (luz natural + luz artificial) e escotoperíodo de oito horas. O programa de iluminação intermitente 30 minutos teve duas fotofases de30min entre a luz natural e uma noite principal de oito horas e duas escotofases e o programa de iluminação intermitente 15 minutos, semelhante ao programa anterior, com duas fotofases de 15min entre a luz natural, uma noite principal de oito horas e duas escotofases. Avaliou-se o consumo de ração (g/ave/dia), produção de ovos (%/ave/dia), peso dos ovos (g), conversão alimentar (g/g), massa de ovos (g), gravidade específica (g/cm³), altura de albúmen (mm), unidade Haugh, rendimento dos componentes do ovo (%), índice de órgãos (%) sendo as médias comparadas pelo teste Tukey (5%). Os resultados apresentados para conversão alimentar, gravidade específica, peso de ovo fresco e armazenado por 14 e 28 dias, rendimento dos componentes do ovo e índices de órgãos não apresentaram diferença (P>0,05). Os programas de iluminação intermitente 30 min e intermitente 15 min apresentaram diferenças significativas (P<0,05) para consumo de ração no segundo, sexto e sétimo período experimental, porém não apresentaram diferenças significativas (P>0,05) na produção de ovos. O peso de ovo, massa do ovo, não apresentou diferença significativa (P>0,05), assim como altura de albúmen e unidade Haugh não apresentaram diferença significativa (P>0,05) para os programas de iluminação contínuo e intermitentes 30min e 15min. Programas de iluminação intermitentes aplicados em poedeiras semipesadas ao início da postura criadas em galpões abertos não afetam negativamente o desempenho zootécnico, a qualidade de ovos e órgãos internos das aves, além de diminuir o tempo de uso de iluminação artificial, reduzindo o consumo de energia elétrica
358

Análise da eficiência de elementos de proteção solar em relação ao sombreamento e a iluminação natural estudo de caso: salas de aula do campus I da UFPB

Marques, Matheus Peixoto de Paula 29 March 2012 (has links)
Made available in DSpace on 2015-05-14T12:09:17Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 11721835 bytes, checksum: d91df33daa9451f253a6f22c8d5b1f6b (MD5) Previous issue date: 2012-03-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work addresses topics such as shading devices, shading and daylighting. It aims at verifying the efficiency of shading devices found classroom buildings at UFPB's campus I, with respect to shading and daylighting. The results of the research focus in the diagnosis of the solutions in the case study, by using three dimensional models (3D) and computer simulation. The digital models were constructed from data collected in field surveys. The computer programs used were the Solar Tool, Ecotect and Daysim. In parallel, we investigated a set of hypothetical situations, considering all the solutions found in the survey, in order to identify the performance of the solutions in other orientation facade. The evaluation of the models was made from performance measures such as the percentage of shading, percentage of sky visibility and useful daylight illuminances (UDI). From the results, we observed that: a) south-oriented façades with unprotected openings allow for environments with higher levels and better distribution of natural lighting; b) a large part of the orientation facade analyzed, except in the northwest and east, more than 50% of the samples obtained a good performance of daylighting; c) the percentage of shading is not enough to say whether an element of sunscreen is effective or not, which can generate misleading conclusions when used alone; d) the correlation of the performance of daylighting and performance of shading with the percentage of sky visibility, showed that for every orientation facade there is an optimal ratio between the percentage of shading and the percentage of sky visibility, and for the facade analyzed, the values of these measures are generally around 88.7% of shading of the opening and 8.1% of sky visibility. / Este trabalho aborda temas como elementos de proteção solar, sombreamento e iluminação natural. Tem como objetivo a verificação da eficiência de proteções solares encontradas em edificações de salas de aula no campus I da UFPB, no que diz respeito ao sombreamento e à iluminação natural. Os resultados da investigação centram-se no diagnóstico das soluções encontradas no estudo de caso, através da utilização de modelos tridimensionais (3D) e simulação computacional. Os modelos digitais foram construídos a partir de dados coletados em levantamento de campo. Os programas computacionais utilizados foram o Solar Tool, Daysim e o Ecotect. Em paralelo, foi investigado um conjunto de situações hipotéticas, considerando todas as soluções encontradas no levantamento, com objetivo de identificar o desempenho das soluções em outras orientações. A avaliação dos modelos foi feita a partir de medidas de desempenho como o percentual de sombreamento, percentual de visibilidade do céu e do useful daylight illuminances (UDI). Com os resultados obtidos foi possível observar que: a) fachadas com aberturas sem proteção orientadas para o Sul geram ambientes com melhores níveis e distribuição da iluminação natural; b) em grande parte das orientações analisadas, exceto na Noroeste e Leste, mais de 50% da amostra obteve um bom desempenho da iluminação natural; c) o percentual de sombreamento não é suficiente para afirmar se um sombreamento é eficaz ou não, podendo gerar conclusões equivocadas quando utilizado isoladamente; d) a correlação da performance da iluminação natural e do desempenho do sombreamento com o percentual de visibilidade do céu, mostrou que para cada orientação existe uma relação ideal do percentual de sombreamento com o percentual de visibilidade do céu, sendo que para as orientações analisadas os valores destas medidas se encontraram, em geral, próximo de 88,7% de sombreamento da abertura e 8,1% de visibilidade do céu.
359

Desempenho termoenergético de habitação de interesse social /

Rios, Gisele Auxiliadora de Almeida. January 2015 (has links)
Orientador: Luis Carlos Origa De Oliveira / Banca: Júlio Borges de Souza / Banca: Mariangela Carvalho Bovolato / Banca: Arnulfo Barroso de Vasconcellos / Banca: Luciane Cleonice Durante / Resumo: Ações de eficiência energética em edificações exigem análise interdisciplinar, capaz de contemplar a complexidade expressa pelas relações de produção do ambiente construído e habitabilidade. O objetivo geral desta pesquisa foi analisar o impacto da aplicação de estratégias bioclimáticas, na eficiência termoenergética de Habitações de Interesse Social (HIS). À partir de um objeto de estudo (HIS) localizado em Cuiabá-MT, as etapas metodológicas compreenderam a avaliação de desempenho térmico e de eficiência energética de três modelos: HIS padrão (HISp) e duas propostas mais eficientes denominados HISeT (com pintura de cor branca na cobertura) e HISeTPJ (com pintura de cor branca na cobertura e nas paredes externas, com alteração das janelas). Por meio de simulação computacional utilizando o EnergyPlus, obteve-se a projeção dos consumos de referência para 13.437 habitações construídas pelo Programa Minha Casa Minha Vida, em Cuiabá-Várzea Grande (período 2009-2013). Os resultados demonstram que o modelo HISeTPJ apresentou melhor desempenho termoenergético, possibilitando uma economia de energia equivalente ao atendimento de mais de 1.000UC, pelo período de um ano. Uma das contribuições deste trabalho foi apresentar uma sistemática para determinação das correlações entre as variações das temperaturas internas e dos consumos de energia elétrica de referência, em função de intervenções na envoltória. Verificou-se a redução de 10,85kWh e de 10,95kWh nos consumos de energia elétrica das HISeT e HISeTPJ, quando ocorrer a redução de 1°C na temperatura interna das mesmas. Este estudo de intervenções na envoltória constitui-se proposta inovadora e com viabilidade econômica demonstrada por meio de Relação Custo-Benefício de 0,38. Evidencia-se a importância de estudos interdisciplinares para definição de políticas públicas para eficiência energética e habitacionais / Abstract: Energy efficiency actions require interdisciplinary analysis, able to contemplate the complexity expressed by environmental production relations built and habitability. The general purpose of this research was to analyze the impact of the application of bioclimatic strategies in thermoenergy efficiency of social housing (HIS). The research adopted a social housing (HIS) located in Cuiabá / MT as object of study, the methodological steps involved the evaluation of thermal performance and energy efficiency based on the Brazilian normative of three models: standard HIS (HISp), and two more efficient scenarios denominated HISeT (with thermal ink painting on the cover) and HISeTPJ (with paint on the cover and external walls, and windows changed). Through computacional simulation using the EnergyPlus, was obtained projection of the reference consumptions for 13,437 housing built by Minha Casa Minha Vida, in Cuiabá-Várzea Grande (2009-2013). The results show that the model presented better HISeTPJ thermoenergetic performance, enabling energy savings equivalent service over 1.000UC for a period of one year. One of the contributions of this work was to present a system for determining the correlations between changes in internal temperatures and electric power reference consumption, due to interventions in the envelope. It was found a reduction 10,95kWh and 10,85kWh on the electric power consumptions of HISeT and HISeTPJ, when it occurs a 1 ° C decrease in internal temperature of the same. This study interventions in the envelope constitutes innovative proposal and economic viability demonstrated through Cost-Benefit 0.38. It ́s evident the importance of interdisciplinary studies for definition of public policies for energy efficiency and housing / Doutor
360

Conversor de único estágio baseado na integração Charge-Pump Valley-Fill para acionamento de LEDs de potência / Single-stage converter based on Charge-Pump Valley-Fill integration to drive power LEDs

Motta, Leandro Chelski da 28 June 2017 (has links)
Este trabalho propõe um sistema eletrônico de único estágio para acionar LEDs de potência empregando os conceitos Charge-Pump e Valley-Fill. Ambos conceitos estão relacionados a configurações topológicas baseadas na integração de um retificador boost de entrada com um inversor meia onda de saída, caracterizando o sistema de único estágio. A configuração Charge-Pump é utilizada para diminuir a ondulação de corrente dos LEDs. A configuração Valley-Fill é empregada para grampear a tensão de barramento CC em níveis inferiores ao valor de pico da tensão da fonte de entrada durante um longo intervalo de tempo no período da rede de alimentação, mantendo o sistema com elevado fator de potência. Desta forma é possível utilizar capacitores de barramento com valores reduzidos. O princípio de funcionamento do conversor proposto, que em regime permanente inclui três modos de operação, será apresentado e analisado. Uma metodologia de projeto, bem como resultados de simulação também serão apresentados para que se possa verificar as características operacionais do sistema. Neste trabalho será utilizado o comando simétrico em uma frequência de comutação de 67 kHz e 90 kHz. A tensão de alimentação é de 220 V e a carga é composta por 18 LEDs conectados em série com potência total de 47 W. / This work proposes a single stage electronic system to drive power LEDs employing Charge-Pump and Valley-Fill concepts. Both concepts are related to topological configurations based on the integration of an input boost rectifier with an output halfbridge inverter, characterizing the single stage system. The Charge-Pump configuration is used to decrease LEDs' current ripple. The Valley-Fill configuration is used to restrict the DC bus voltage at levels lower than the input source voltage peak value over a long period of time in the source period, keeping a high power-factor system. Thus, it is possible to use bus capacitors with reduced values. The proposed converter operation principle, which in steady-state includes three operation modes, that will be presented and analyzed. A design methodology as well as simulation results will also be presented so that the system operational characteristics can be verified. In this paperwork, the symmetric command will be used at a switching frequency of 67 KHz. The supply voltage is 220 V and the load is composed of 18 LEDs series connected with total power of 47 W.

Page generated in 0.1305 seconds