Análise comparativa entre o sistema digital Digora e a digitalização da radiografia convencional na avaliação da densidade radiográfica do processo de reparo alveolar

Silva, Jordan Lima da [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T20:21:53Z : No. of bitstreams: 1 silva_jl_dr_araca.pdf: 803850 bytes, checksum: a13420fee8c9eac95ae85dcbb9659489 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A película radiográfica é uma tecnologia que os cirurgiões-dentistas estão mais familiarizados estando confortáveis em termos da técnica e da interpretação. A radiografia digital é um avanço que está sendo adotado lentamente pelo cirugião-dentista, oferecendo algumas vantagens distintas sobre a película. O propósito deste estudo é comparar o sistema radiográfico digital Digora com a digitalização da radiografia convencional, avaliando a densidade radiográfica do processo de reparo alveolar na região de molares inferiores inclusos após exodontia em humanos. Os princípios e técnica para a exodontia foram padronizados assim como para a obtenção das imagens radiográficas. Imagem sugestiva de tecido ósseo mineralizado foi observada nos períodos de 60 e 90 dias, comparando os sistemas digital e convencional digitalizado. A estatística sugere perda nos valores da densidade, nos períodos estudados, para o sistema das radiografias convencionais digitalizadas em relação ao sistema Digora. Os resultados obtidos permitem concluir que a qualidade da imagem convencional digitalizada é menos precisa quando comparada a digital, para o acompanhamento do reparo ósseo pós-operatório. / Conventional radiographic film It is a technology that the surgeon-dentists more are made familiar being comfortable to in terms of the technique and the interpretation. The digital x-ray is an advance that is being adopted slowly for the dentistry. The digital image incorporates computer science in the captation, the exposition, the distinction, and the storage of the direct radiographic images. The digital image offers some distinct advantages on the film, but as all the emergent technology presents new different challenges and so that the users surpass them. The intention of this study was to evaluate through the radiograpic examination for the Digora system the radiographic density of the behavior of the fabric bone during the process of repair in the region of molar enclosed inferiors after exodontia in human beings. Standardized procedures had been used for the surgery of the patients as well as for the attainment of the radiographic images. Bone suggestive fabric image mineralized was observed in the periods of 60 and 90 days comparing the conventional and digital method. The gotten results allow to conclude that the quality of the digital conventional image is lower efficient than the digital one gotten directly for the accompaniment of the postoperative bone repair.
12

Confiabilidade de dois métodos radiográficos para determinação da maturação esquelética por meio de imagens das vértebras cervicais e concordância com imagens de mão e punho /

Lima, Juliana Ferreira. January 2018 (has links)
Orientador: Guilherme Monteiro Tosoni / Resumo: O objetivo deste estudo foi avaliar a confiabilidade de dois métodos radiográficos de determinação da maturação esquelética das vértebras cervicais e a concordância com o método baseado nas imagens radiográficas de mão e punho. Foram analisadas imagens radiográficas digitais cefalométricas laterais e de mão e punho de 120 indivíduos, com idades variando entre 6 e 18 anos. Para o estudo da repetibilidade e reprodutibilidade, as imagens radiográficas foram interpretadas por 4 examinadores (2 radiologistas e 2 ortodontistas) em dois momentos distintos de acordo com os métodos de Hassel e Farman (VC1) e Baccetti et al. (VC2). Para o estudo de concordância, o método de Fishman também foi realizado pelos quatro examinadores. Para as análises estatísticas foi utilizada estatística Kappa (ҡ), com ponderação linear, seguida do cálculo dos intervalos de confiança (IC95%) e Coeficiente de Correlação Intraclasse (CCI). Os resultados da análise intra-examinador indicaram calibração "quase perfeita" para os quatro examinadores (ҡ>0,81) em todos os métodos de análise. Os limites inferiores dos IC estiveram todos acima de 0,71 para a análise inter-examinador. Os valores de CCI para reprodutibilidade inter-examinador foram considerados "excelentes" para os limites inferiores de todos os IC (≥0,91). Embora a proporção total de diagnósticos concordantes (acurácia) obtida nos métodos VC1 e VC2 tenha sido, respectivamente, 42% e 50% para os ortodontistas e 42% e 40% para os radiologistas, o cruza... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate the reliability of two radiographic methods to determine the skeletal maturation of the cervical vertebrae and the concordance with the method based on hand and wrist radiographic images. Were analyzed lateral cephalogram, hand and wrist digital radiographic images of 120 individuals, ranging from 6 to 18 years. For the study of repeatability and reproducibility, the images were interpreted by 4 examiners (2 radiologists and 2 orthodontists) on distinct moments, according to the methods of Hassel e Farman (CV1) and Bacetti et al. (CV2). For the concordance study, the Fishman method was also applied. Statistical analysis was performed using Kappa (ҡ), with linear weighting, followed by the calculation of confidence intermission (CI95%) and the Intraclass Correlation Coefficient (ICC). The intra-examiner analysis results indicated 'almost perfect' calibration for the examiners (ҡ>0,81) in all methods. The lower limits of Cis were all above 0.71 for the interexaminer analysis. ICC values for inter-examiner reproducibility were considered 'excellent' for the lower limits of all Cis (≥0.91). Although the total proportion of concordant diagnosis (accuracy) obtained on CV1 and CV2 methods was 42% and 50% for orthodontists and 42% and 40% for radiologists, the crossing of all Cis95% showed no significant difference. Both methods of determination of skeletal maturation of the cervical vertebrae are reliable, since they presented excellent repeatability and reproducibility. These methods showed substantial concordance with the method using radiographic images of the hand and wrist. Moreover, orthodontists and radiologists interpreted them with the same precision / Mestre
13

Estudo radiográfico digital e densitométrico em mandíbulas de suínos, submetidas a osteotomia com brocas de alta e baixa rotação, com refrigeração líquida

Monti, Lira Marcela [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:52:59Z : No. of bitstreams: 1 monti_lm_me_araca.pdf: 287560 bytes, checksum: 074e03765d9ead5baba4ea3ffcdf36ee (MD5) / Universidade Estadual Paulista (UNESP) / Avaliou-se, por meio de exames radiográficos digitais e densitométricos, a influência do tipo de instrumento rotatório para corte, no processo de reparação óssea após osteotomias em mandíbula de suíno em tempos controlados. Foram utilizados para o estudo oito suínos da raça Large White, com peso corpóreo inicial variando de 25 a 30 Kg. Dois cortes transversais do meio à base de mandíbula direita foram realizados, um por meio de instrumento rotatório de alta rotação e o outro pela ação da baixa rotação, ambos com irrigação líquida. Após períodos pré-estabelecidos (7, 28, 60 e 90 dias) os animais foram sacrificados e suas mandíbulas retiradas para estudos radiográficos digitais diretos e indiretos, pelo sistema DIGORA e ODR e de densitometria óptica por imagens radiográficas pelo sistema CROMOX. Nos períodos iniciais (7 e 28 dias) as densitometrias foram maiores na região das osteotomias realizadas com alta rotação e nos períodos finais (60 e 90 dias) as densitometrias foram maiores nas osteotomias feitas com baixa rotação, indicando uma melhor reparação óssea final quando do uso de baixa rotação. A análise qualitativa do processo de reparação foi feita pelo sistema ODR, que possibilitou a obtenção de imagens digitais tridimensionais e coloridas, permitindo comparação das espessuras ósseas com as de uma cunha de alumínio, evidenciando que aos sessenta dias a reparação óssea estava aparentemente completa. Os histogramas do DIGORA apontaram valores de médias de nível de cinza nas áreas de osteotomia, evidenciando uma maior quantidade de tons de cinza nas osteotomias de alta rotação nos primeiros tempos, e nas osteotomias com baixa-rotação nos tempos finais. / It was evaluated, through digital and densitometric radiographic exams, the influence of the type of rotating instrument for cut, in the process of bony repair after osteotomy in swine jaw in controlled times. They were used for the study eight Large White swines, with initial corporal weight varying from 25 to 30 Kg. Two traverse cuts of the middle to the base of right jaw were accomplished, one through rotating instrument of high rotation and the other for the action of the low rotation, both with liquid irrigation. After established periods (7, 28, 60 and 90 days) the animals were sacrificed and your mandibles retired for direct and indirect digital radiografic studies, for the DIGORA and ODR systems and of optical densitometry for radiographic images for the CROMOX system. In the initial periods (7 and 28 days) the densitometry were larger in osteotomy areas accomplished with high rotation and in the final periods (60 and 90 days) the densitometry were larger in the osteotomy done with low rotation, indicating a better final bony repair when of the use of low rotation. The qualitative analysis of the repair process was made by the ODR system, that made possible obtaining three-dimensional and colored digital images, allowing comparison of the bony thickness with the one of a wedge of aluminum, evidencing that to the sixty days the bony repair was apparently complete. The histograms of DIGORA pointed values of the averages of ash tones in the osteotomy areas, evidencing a larger amount of ash tones in the osteotomy of high rotation in the first times, and in the osteotomy with low-rotation in the final times.
14

Radiografia digital e a tecnica de subtração no monitoramento da desmineralização e remineralização do esmalte dentario / Digital radiography and the subtraction technique for monitoring dental enamel demineralization and remineralization

Bittar-Cortez, Juliana Araujo 25 January 2008 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T07:50:35Z (GMT). No. of bitstreams: 1 Bittar-Cortez_JulianaAraujo_D.pdf: 5858192 bytes, checksum: 3d3d3c7dbc08b34e4b7c483e7316bd88 (MD5) Previous issue date: 2008 / Resumo: O objetivo deste estudo in vitro foi comparar dois protocolos de remineralização em lesões de cárie no esmalte dentário, avaliados por meio de análises de cálcio (Ca) e fósforo (Pi), dureza do esmalte, microscopia de luz polarizada e subtração radiográfica digital (SRD); avaliar a viabilidade da utilização de dois diferentes sistemas de radiografias digitais, placa PSP (photostimulable storage phosphor) e sensor CMOS (complementary metal oxide semicondutor), no diagnóstico de desmineralizações, e a acurácia das radiografias digitais convencionais (RDC) e três métodos de SRD (linear, avançada e logarítmica) no diagnóstico de mudanças minerais; e comparar o ruído e reprodutibilidade das imagens de SRD lineares e logarítmicas produzidas a partir de dois sistemas de radiografias digitais. Para isso, lesões de cárie artificiais foram criadas em 100 superfícies proximais de dentes hígidos. Vinte dentes foram mantidos como controle e oitenta foram submetidos a dois diferentes protocolos de remineralização em 4 e 8 semanas, com a contínua imersão em saliva artificial e um tratamento adicional com flúor. Radiografias digitais foram realizadas antes e depois dos protocolos de remineralização. Cinco examinadores avaliaram a desmineralização e as mudanças minerais nas RDC, dispostas lado a lado, e três métodos da SRD. As análises de Ca / Pi e a colocação dos dentes na solução remineralizante foram considerados como padrão ouro. A média dos tons de cinza e o desvio padrão (DP) no histograma foram também mensurados. As concentrações de Ca e Pi na saliva artificial após os tratamentos foram significativamente menores do que a solução original (p<0,05); e por meio da SRD foi possível verificar diferenças entre as imagens. Entretanto, o teste de dureza e a microscopia de luz polarizada não detectaram nenhuma alteração. O sistema CMOS foi significativamente mais acurado do que a sistema PSP no diagnóstico da desmineralização e mudanças minerais, assim como a SRD linear no diagnóstico de mudanças minerais. Também foram estatisticamente diferentes os valores da média dos níveis de cinza e do DP entre os dois sistemas. Foi concluído que (a) o tratamento adicional de flúor promoveu valores maiores de ganho mineral; (b) a análise de Ca / Pi na saliva artificial foi o método mais sensível na avaliação de alteração mineral; (c) a imagem de SRD linear é um método válido na detecção do aumento de intensidade, como sinal de ganho mineral; e (d) as imagens de SRD utilizando as placas PSP tiveram um menor ruído do que nas imagens geradas pelo sensor CMOS / Abstract: The aim of this in vitro study was to compare two remineralization protocols of artificial carious lesions in enamel, evaluated by Calcium (Ca) and Phosphorus (Pi) analysis, cross-section hardness test, polarized light microscopy and digital subtraction images (DSR); to assess the feasibility of using two different systems of digital radiography, photostimulable storage phosphor (PSP) plate and complementary metal oxide semiconductor (CMOS) sensor on the demineralization diagnosis, and the accuracy of digital conventional radiographs (DCR) and three methods of DSI (linear, advanced and logarithmic) on mineral changes diagnosis; and, to compare noise and reproducibility in linear and logarithmic DSI produced from two digital radiography systems. Artificial caries-like lesions on 100 approximal surfaces of sound teeth were produced. Twenty teeth were kept as control and eighty teeth were subjected to two different remineralization protocols for 4 and 8 weeks, with continuous immersion in artificial saliva, and additional fluoride treatment. Digital radiographs were taken before and after the remineralization protocols. Five examiners assessed demineralization and mineral changes on DCR, placed side by side, and three methods of DSI. Ca / Pi analysis and the placement of the teeth on the remineralization solution was the gold standard. The mean shades of gray and the standard deviation (SD) of the histogram were also assessed. The concentrations of Ca and Pi in the artificial saliva after the treatments were significantly lower than the original solution (p<0.05); and DSR showed differences between the images. However, the Hardness test and polarized light microscopy did not detect any changes. CMOS system was significantly more accurate than PSP system on demineralization and mineral changes diagnosis, and also linear DSR on mineral changes diagnosis. It was also statistically significant different the values of mean shades of gray and SD between both systems. It was concluded that (a) the additional Fluoride treatment provided higher values of mineral gained; (b) Ca / Pi analysis in the artificial saliva were the most sensitive method of mineral change evaluation; (c) linear DSI is a valuable method to disclose an intensity increase, as a sign of mineral gained; and (d) DSR images created from PSP plates had less noise than images produced from CMOS sensor / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
15

Método computacional automático para correção do efeito \"heel\" nas imagens radiográficas / An automatic computational method for correction of the heel effect in radiographic images

Nascimento, Marcelo Zanchetta do 18 March 2005 (has links)
O diagnóstico radiográfico é baseado na análise das diferenças das densidades ópticas (DO) do filme, que deveriam ser provocadas apenas pelas estruturas anatômicas do paciente. Entretanto, a intensidade do feixe de raios X não é uniforme devido a um efeito intrínseco do equipamento de aquisição de imagem, conhecido como efeito \"heel\". Estas variações prejudicam tanto a análise visual quanto o processamento computacional (CAD) das pequenas estruturas anatômicas. O presente trabalho apresenta um método computacional que corrige as diferenças de densidades ópticas produzidas na radiografia pelo efeito \"heel\". Esse método foi implementado utilizando ambiente de programação Delphi, rotinas em C e Matlab. O método simula a distribuição da intensidade ao longo do campo de radiação, determinando o caminho de absorção que os fótons sofrem dentro do alvo utilizando os modelos de Kramers e Fritz Livingston. Calcula a correlação espacial entre a radiografia e a imagem simulada, localizando o eixo anodo/catodo e o centro do campo nas duas imagens, empregando a função de correlação estatística de Pratt e a função de mapeamento de Zitová e Flusser. Calcula tanto os percentuais de radiação recebidos para cada ponto simulado em relação à radiação ao centro do campo, quanto os percentuais dos níveis de cinza de cada pixel da radiografia e corrige esse valor em função do correspondente na simulação. O algoritmo desenvolvido permitiu determinar a posição do centro do campo de radiação com precisão em torno de 1% e eliminou aproximadamente 90% do efeito \"heel\" na radiografia permitindo que os objetos apresentassem densidades ópticas coerentes com suas absorções específicas. Um estudo preliminar mostrou que esse método poderá ser utilizado como pré-processamento dos sistemas CAD. / The radiographic diagnosis is based on the analysis of the film optical density differences that should be created only by the patient anatomical structures. However, the intensity of the x-ray beam is not uniform due to an intrinsic effect to the image acquisition equipment, known as heel effect. These variations damage the visual analysis as well the (CAD) computer processing of the small anatomical structures. The current work presents a computer method that corrects the optical densities differences generated in the radiography by heel effect. This method was implemented using Delphi Programming Environment, routines in C and Matlab. The method simulates the intensity distribution along the radiation field, determining the absorption path that photons suffer inside the target using the models of Kramers and Fritz and Livingston. It calculates the space correlation between the radiography and the simulated image, determining the anode/cathode axis and the field center in the two images, using the statistics function of Pratt and the mapping function of Zitová and Flusser. It calculates as much the received radiation, percentage for each simulated point in relation the field center radiation, as the gray scales percentage of each radiography pixel and corrects their values as function of the correspondent in the simulation. The developed algorithm has allowed to determine the center position of the radiation field with about 1% precision and approximately eliminated 90%of the heel effect in the radiography, allowing the objects to present optical densities coherent with their specific absorptions. A preliminary study has showen that this method can be used as preprocessing of CAD systems.
16

Análise densitométrica digital do processo de reparo em dentes de rato reimplantados

Giovanini, Ellen Greves [UNESP] 30 November 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-11-30Bitstream added on 2014-06-13T20:13:38Z : No. of bitstreams: 1 giovanini_eg_me_araca.pdf: 1544057 bytes, checksum: 1b518f21ba8bc63249a3f29eb78ba402 (MD5) / A avulsão dentária é caracterizada pelo completo deslocamento do dente do seu alvéolo e a melhor forma de tratar um dente avulsionado é o seu reimplante. Mesmo diante das melhores circunstâncias os reimplantes tardios falham devido à reabsorção radicular que é detectada apenas durante a avaliação radiográfica. A imagem digital surgiu como um recurso diagnóstico rápido e de fácil utilização sendo considerada precisa. Para diminuir a variabilidade de interpretação é sugerida a análise radiográfica quantitativa por meio da densidade radiográfica. O propósito deste trabalho foi analisar comparativamente o processo de reparo do reimplante dental em ratos utilizando a análise densitométrica no sistema digital Digora. Foram utilizados 30 ratos machos, divididos em 3 grupos de 10 animais, que tiveram seu incisivo superior direito extraído e tratado da seguinte forma: grupo I - reimplante imediato, grupo II - reimplante tardio sem tratamento e o grupo III - reimplante tardio com tratamento da superfície radicular utilizando raspagem do ligamento e fluoreto de sódio. Os animais foram sacrificados após 60 dias do ato operatório, suas maxilas foram separadas e as imagens radiográficas obtidas de forma que sobre cada placa óptica ficassem as duas hemimaxilas (tratada e controle), o penetrômetro de alumínio e a identificação. Foram realizadas medidas de densidade em áreas padronizadas no sistema Digora. Os valores densitométricos encontrados foram submetidos à análise de variância e teste de Tuckey, e análise não paramétrica do número de áreas de reabsorção. Podemos concluir que a análise densitométrica constitui um importante exame complementar para o acompanhamento dos reimplantes uma vez que permitiu a detecção de reabsorção radicular em todos os grupos, cuja ordem decrescente de envolvimento foi o grupo do reimplante tardio sem tratamento... / The dental replanted has been considered the best treatment of the tooth avulsion, which is characterized by complete alveolar dislodgment of the tooth. Despite of the adequate clinical situations, the delayed replantation fails due to the root resorption that is detected during the radiographic evaluation. The use of the digital image represent a fast and easy diagnostic resource, furthest more precise. The quantitative radiographic analysis has been suggested to reduce the interpretation variability through the radiographic density. The purpose of this work was to analyze the process of repair of the dental replanted using the digital densitometry in the Digora system. The 30 male rats were divided in 3 groups of 10 animals, and their right superior incisor were extracted and treated agreement with their group: group I - immediate replanted, group II - delayed replanted without treatment and the group III - delayed replanted with treatment of the root surface using fluoride of sodium. The animals were sacrificed after 60 days operative act, your jawbones were separate and the radiographic images obtained so that on each optical plate were the two jawbones (treated and control), the aluminum step wedge and the identification. The radiographic density of radicular standardized area in Digora system was measured. The densitometric values were submitted to the variance analysis and test of Tuckey and analysis non parametric of the number of areas root resoption. We can end that digital densitometry analysis it an important complementary for replanted evaluation once it allowed the detection of root reabsorption in all of the groups, whose decreasing order of involvement was the group of the delayed replanted without treatment, following for the delayed replanted with treatment and last the immediate replanted.
17

Método computacional automático para correção do efeito \"heel\" nas imagens radiográficas / An automatic computational method for correction of the heel effect in radiographic images

Marcelo Zanchetta do Nascimento 18 March 2005 (has links)
O diagnóstico radiográfico é baseado na análise das diferenças das densidades ópticas (DO) do filme, que deveriam ser provocadas apenas pelas estruturas anatômicas do paciente. Entretanto, a intensidade do feixe de raios X não é uniforme devido a um efeito intrínseco do equipamento de aquisição de imagem, conhecido como efeito \"heel\". Estas variações prejudicam tanto a análise visual quanto o processamento computacional (CAD) das pequenas estruturas anatômicas. O presente trabalho apresenta um método computacional que corrige as diferenças de densidades ópticas produzidas na radiografia pelo efeito \"heel\". Esse método foi implementado utilizando ambiente de programação Delphi, rotinas em C e Matlab. O método simula a distribuição da intensidade ao longo do campo de radiação, determinando o caminho de absorção que os fótons sofrem dentro do alvo utilizando os modelos de Kramers e Fritz Livingston. Calcula a correlação espacial entre a radiografia e a imagem simulada, localizando o eixo anodo/catodo e o centro do campo nas duas imagens, empregando a função de correlação estatística de Pratt e a função de mapeamento de Zitová e Flusser. Calcula tanto os percentuais de radiação recebidos para cada ponto simulado em relação à radiação ao centro do campo, quanto os percentuais dos níveis de cinza de cada pixel da radiografia e corrige esse valor em função do correspondente na simulação. O algoritmo desenvolvido permitiu determinar a posição do centro do campo de radiação com precisão em torno de 1% e eliminou aproximadamente 90% do efeito \"heel\" na radiografia permitindo que os objetos apresentassem densidades ópticas coerentes com suas absorções específicas. Um estudo preliminar mostrou que esse método poderá ser utilizado como pré-processamento dos sistemas CAD. / The radiographic diagnosis is based on the analysis of the film optical density differences that should be created only by the patient anatomical structures. However, the intensity of the x-ray beam is not uniform due to an intrinsic effect to the image acquisition equipment, known as heel effect. These variations damage the visual analysis as well the (CAD) computer processing of the small anatomical structures. The current work presents a computer method that corrects the optical densities differences generated in the radiography by heel effect. This method was implemented using Delphi Programming Environment, routines in C and Matlab. The method simulates the intensity distribution along the radiation field, determining the absorption path that photons suffer inside the target using the models of Kramers and Fritz and Livingston. It calculates the space correlation between the radiography and the simulated image, determining the anode/cathode axis and the field center in the two images, using the statistics function of Pratt and the mapping function of Zitová and Flusser. It calculates as much the received radiation, percentage for each simulated point in relation the field center radiation, as the gray scales percentage of each radiography pixel and corrects their values as function of the correspondent in the simulation. The developed algorithm has allowed to determine the center position of the radiation field with about 1% precision and approximately eliminated 90%of the heel effect in the radiography, allowing the objects to present optical densities coherent with their specific absorptions. A preliminary study has showen that this method can be used as preprocessing of CAD systems.
18

Exatidão de filtros de imagem na avaliação radiográfica do nível ósseo peri-implantar / Accuracy of enhancement filters in measuring in-vitro periimplant bone level

Vaz, Sergio Lins de Azevedo, 1984- 20 August 2018 (has links)
Orientador: Paulo Sérgio Flores Campos / Texto do capítulo 1 em inglês / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T12:07:20Z (GMT). No. of bitstreams: 1 Vaz_SergioLinsdeAzevedo_M.pdf: 1201820 bytes, checksum: c01a9a7bcc2ca60b934986c91f46e192 (MD5) Previous issue date: 2012 / Resumo: O objetivo neste trabalho foi identificar a exatidão de alguns filtros de imagem na mensuração do nível ósseo peri-implantar, por meio da radiografia digital. Para isso, vinte implantes de titânio (Titamax, Neodent, Curitiba, PR, Brasil) foram instalados em seis fragmentos de costelas bovinas, nas quais foram criados defeitos do tipo perda óssea. Utilizando um sistema intra-bucal de placas de fósforo (Vista Scan, Dürr Dental, Beitigheim-Bissingen, Alemanha), radiografias periapicais foram realizadas posicionando os implantes segundo a técnica do paralelismo. Após a obtenção das imagens, nove filtros do software DBSWIN foram aplicados: fine, caries 1, caries 2, perio, endo, noise reduction, invert, emboss e sculpture. Um avaliador mensurou as distâncias entre o ombro do implante à porção mais apical do defeito no software Image J. Os defeitos também foram mensurados nas costelas bovinas utilizando um paquímetro digital. O teste não-paramétrico de Friedman comparou os valores obtidos nas imagens com aplicação dos filtros aos encontrados nas imagens originais e nas costelas bovinas, adotando nível de significância de 5%. Os resultados mostraram diferenças estatisticamente significantes para os filtros caries1, caries2, endo e perio (P < 0.05) tanto em relação às imagens originais, quanto em relação às mensurações obtidas com o paquímetro. As mensurações obtidas com as imagens originais, filtros fine e emboss foram mais próximas às obtidas com o paquímetro. Concluiu-se que os filtros fine e emboss foram os mais exatos na mensuração do nível ósseo peri-implantar, sendo equiparáveis às imagens originais. Os filtros caries1, caries2, endo e perio foram os menos exatos, não sendo indicados para este fim / Abstract: This study aimed to identify the accuracy of some enhancement filters of an intraoral phosphor-plate system for measuring the simulated periimplant bone level. Twenty titanium implants (Titamax, Neodent, Curitiba, PR, Brazil) were placed into six fragments of bovine ribs and defects simulating bone loss were created. Periapical radiographs were taken with a phosphor-plate system (Vista Scan, Dürr Dental, Beitigheim-Bissingen, Germany) according to the paralleling standard technique, and nine enhancement filters were applied: fine, caries 1, caries 2, perio, endo, noise reduction, invert, emboss and sculpture. An oral radiologist measured on the Image J software the distance from the neck of the implant to the most apical contact of the bone with the implant. The Friedman non-parametric test compared the radiographic measurements to those obtained on the bovine ribs with a digital caliper. The significance level adopted was 5%. The caries1, caries2, endo, and perio filters resulted on measurements statistically different from both the original images and the measures of the digital caliper (P < 0.05). In conclusion, the fine and emboss filters resulted on the most precise filters, with similar measures to the original images. The caries1, caries2, endo, and perio filters were the less accurate for measuring the periimplant bone level / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
19

Parâmetros quantitativos obtidos por tomografia computadorizada de dupla-energia na avaliação da perfusão pulmonar em modelo experimental de embolia e lesão pulmonar / Quantitative parameters obtained from dual-energy computed tomography in the evaluation of pulmonary perfusion in an experimental model of embolism and alveolar damage

Kay, Fernando Uliana 10 August 2018 (has links)
Nesta tese, buscou-se avaliar se a tomografia computadorizada de duplaenergia pós-contraste (TCDE) é capaz de detectar diferenças regionais da perfusão pulmonar em um modelo animal suíno incluindo variações de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, comparando estes resultados com os obtidos pela perfusão de primeira passagem com a tomografia computadorizada dinâmica (TCD). Dez suínos landrace foram divididos em Grupos A (N = 5, controle) e B (N = 5). Animais do Grupo B foram submetidos ao protocolo de lesão alveolar induzida por ventilação mecânica (LPIV). O volume sanguíneo perfundido e o fluxo sanguíneo pulmonar foram, respectivamente, estimados pela TCDE (%VSPTCDE) e pela TCD (FSPTCD), em diversas condições experimentais: posição supina versus prona, presença versus ausência de LPIV, presença ou ausência de oclusão da artéria pulmonar. A correlação entre %VSPTCDE e FSPTCD foi moderada (R = 0,60) com ampla variabilidade (intervalo 0,35-0,91) entre animais. %VSPTCDE e FSPTCD demonstraram padrões similares de heterogeneidade da perfusão pulmonar nas diferentes condições experimentais. Entretanto, reduções do %VSPTCDE causadas pela oclusão com balão foram em média -29,32 %, enquanto reduções do FSPTCD foram em média -86,78 % (p < 0,001). Estimativas quantitativas do VSPTCDE tiveram um erro médio de +4.3 ml/100g em comparação com o FSPTCD, com limites de concordância de 95 % entre -16,6 ml/100g e 25,1 ml/100g. A TCDE póscontraste é capaz de prover estimativas semiquantitativas que refletem a heterogeneidade regional da perfusão pulmonar causada por mudanças de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, apresentando moderada correlação com a perfusão de primeira passagem pela TCD / We aimed to evaluate whether contrast-enhanced dual-energy CT (DECT) detects regional pulmonary perfusion changes in a swine model of acute lung injury, with variations in decubitus and transient occlusion of the pulmonary artery, comparing these results with those obtained with dynamic CT perfusion (DynCT). Ten landrace swine were assigned to Groups A (N = 5, control) and B (N = 5). Group B was subjected to ventilator-induced lung injury (VILI). Perfused blood volume and pulmonary blood flow were quantified by DECT (PBVDECT) and DynCT (PBFDynCT), respectively, under different settings: supine versus prone, and with/without balloon occlusion of a pulmonary artery (PA) branch. Correlation of regional PBVDECT versus PBFDynCT was moderate (R = 0.60) with high variability (range 0.35-0.91) among the animals. Regional pulmonary perfusion changes assessed by %PBVDECT agreed with PBFDynCT in response to decubitus changes, lung injury and balloon occlusion in the multivariate analysis. However, reductions in %PBVDECT caused by balloon occlusion were in average -29.32 %, whereas reductions in PBFDynCT were in average -86.78 % (p < 0.001). Quantitative estimates of PBVDECT had a mean bias of +4.3 ml/100g in comparison with PBVDynCT, with 95 % confidence intervals between -16.6 ml/100g and 25.1 ml/100g. Semiquantitative contrastenhanced DECT reflects regional changes in perfusion caused decubitus changes, acute lung injury, and balloon occlusion of the PA, with moderate correlation in comparison with DynCT
20

Parâmetros quantitativos obtidos por tomografia computadorizada de dupla-energia na avaliação da perfusão pulmonar em modelo experimental de embolia e lesão pulmonar / Quantitative parameters obtained from dual-energy computed tomography in the evaluation of pulmonary perfusion in an experimental model of embolism and alveolar damage

Fernando Uliana Kay 10 August 2018 (has links)
Nesta tese, buscou-se avaliar se a tomografia computadorizada de duplaenergia pós-contraste (TCDE) é capaz de detectar diferenças regionais da perfusão pulmonar em um modelo animal suíno incluindo variações de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, comparando estes resultados com os obtidos pela perfusão de primeira passagem com a tomografia computadorizada dinâmica (TCD). Dez suínos landrace foram divididos em Grupos A (N = 5, controle) e B (N = 5). Animais do Grupo B foram submetidos ao protocolo de lesão alveolar induzida por ventilação mecânica (LPIV). O volume sanguíneo perfundido e o fluxo sanguíneo pulmonar foram, respectivamente, estimados pela TCDE (%VSPTCDE) e pela TCD (FSPTCD), em diversas condições experimentais: posição supina versus prona, presença versus ausência de LPIV, presença ou ausência de oclusão da artéria pulmonar. A correlação entre %VSPTCDE e FSPTCD foi moderada (R = 0,60) com ampla variabilidade (intervalo 0,35-0,91) entre animais. %VSPTCDE e FSPTCD demonstraram padrões similares de heterogeneidade da perfusão pulmonar nas diferentes condições experimentais. Entretanto, reduções do %VSPTCDE causadas pela oclusão com balão foram em média -29,32 %, enquanto reduções do FSPTCD foram em média -86,78 % (p < 0,001). Estimativas quantitativas do VSPTCDE tiveram um erro médio de +4.3 ml/100g em comparação com o FSPTCD, com limites de concordância de 95 % entre -16,6 ml/100g e 25,1 ml/100g. A TCDE póscontraste é capaz de prover estimativas semiquantitativas que refletem a heterogeneidade regional da perfusão pulmonar causada por mudanças de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, apresentando moderada correlação com a perfusão de primeira passagem pela TCD / We aimed to evaluate whether contrast-enhanced dual-energy CT (DECT) detects regional pulmonary perfusion changes in a swine model of acute lung injury, with variations in decubitus and transient occlusion of the pulmonary artery, comparing these results with those obtained with dynamic CT perfusion (DynCT). Ten landrace swine were assigned to Groups A (N = 5, control) and B (N = 5). Group B was subjected to ventilator-induced lung injury (VILI). Perfused blood volume and pulmonary blood flow were quantified by DECT (PBVDECT) and DynCT (PBFDynCT), respectively, under different settings: supine versus prone, and with/without balloon occlusion of a pulmonary artery (PA) branch. Correlation of regional PBVDECT versus PBFDynCT was moderate (R = 0.60) with high variability (range 0.35-0.91) among the animals. Regional pulmonary perfusion changes assessed by %PBVDECT agreed with PBFDynCT in response to decubitus changes, lung injury and balloon occlusion in the multivariate analysis. However, reductions in %PBVDECT caused by balloon occlusion were in average -29.32 %, whereas reductions in PBFDynCT were in average -86.78 % (p < 0.001). Quantitative estimates of PBVDECT had a mean bias of +4.3 ml/100g in comparison with PBVDynCT, with 95 % confidence intervals between -16.6 ml/100g and 25.1 ml/100g. Semiquantitative contrastenhanced DECT reflects regional changes in perfusion caused decubitus changes, acute lung injury, and balloon occlusion of the PA, with moderate correlation in comparison with DynCT