• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 113
  • 80
  • 11
  • 8
  • 5
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 241
  • 69
  • 68
  • 59
  • 58
  • 58
  • 56
  • 51
  • 48
  • 41
  • 40
  • 28
  • 27
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

利用新式生物反應器培養動物細胞生產日本腦炎病毒 / Using a novel bioreactor to cultivate animal cell for Japanese encephalitis virus production

王琪婷, Chi-ting Wang January 1994 (has links)
摘 要 本研究主要是探討利用新式生物反應器以固定化細胞培養技術生產日本腦炎病毒(Japanese encephalitis virus;JEV)之研究,首先根據所培養細胞的生長特性與原有生物反應器之缺點,利用已改良設計之新式生物反應器,評估此新式生物反應器適用性、效能,以及所培養細胞之生長代謝情形與病毒力價。整個實驗過程大致分為幾個階段,第一個階段探討細胞固定化培養之最適化培養條件與生長代謝情形,第二個階段找出細胞固定化培養於此新式生物反應器中最佳生長狀態,最後一個階段為病毒的培養。實驗後發現Vero細胞經固定化貼附於FIBRA-CEL®載體上,可擴大培養於新式生物反應器,Vero細胞最佳生長量達到6.6×106cells/mL。希望藉由此改良之新式生物反應器提供細胞與病毒一個良好之生長培養環境,獲得高產量、品質穩定一致之細胞生物製品,以提供ㄧ設備簡單與製程操作容易、低成本、低能源消耗之細胞製品生產基座。 / Abstract In this study, we investigated the production of Japanese encephalitis virus (JEV) by the immobilized cell technology in a novel bioreactor. According to the disadvantages of original bioreactor and growth characteristics of cell culture, we evaluated the suitability and efficiency of a design-improved novel bioreactor as well as the growth and metabolic situation of cultured cells and titers of JEV. All studies including three major stages: (1) investigation of the optimal conditions and metabolic situation for the growth of immobilized cells, (2) finding the optimal conditions for the growth of immobilized cells in this novel bioreactor, and (3) growth of JEV using immobilized cells in this novel bioreactor. Our results showed that after immobilization on the FIBRA-CEL® carries, Vero cells can grow on the novel bioreactor up to the density of 6.6 × 106 cells/mL. Hopefully, the improvement of the novel bioreactor will provide an optimal growth condition for both the cells and viruses. Furthermore, it will also provide the basis for the production of cell products with advantages of simple-equipped, easy-to-operate, low cost, and low energy consumption. / 目 錄 誌謝------------------------------------------------- i 中文摘要 -------------------------------------------- ii 英文摘要 -------------------------------------------- iii 目錄 -------------------------------------------- iv 表目錄 -------------------------------------------- v 圖目錄 -------------------------------------------- vi 第一章 緒論---------------------------------------- 1 第二章 文獻探討------------------------------------ 3 第一節 日本腦炎病毒疫苗---------------------------- 3 第二節 動物細胞的培養------------------------------ 4 第三節 載體上動物細胞的培養------------------------ 5 第四節 動物細胞培養於生物反應器-------------------- 7 第三章 材料與方法---------------------------------- 10 一 細胞株的培養-------------------------------- 10 二 細胞冷凍保存與解凍培養---------------------- 10 三 細胞滾瓶培養-------------------------------- 11 四 病毒株的培養-------------------------------- 12 五 固定化載體材料製備-------------------------- 12 六 載體上細胞數的測定-------------------------- 12 七 細胞貼壁率的計算---------------------------- 13 八 生物反應器結構特性與固定化細胞培養---------- 13 九 日本腦炎病毒力價測定------------------------ 19 十 葡萄糖的測定-------------------------------- 19 第四章 結果與討論---------------------------------- 20 一 固定化載體材料比例對Vero細胞生長的影響------ 20 二 細胞貼附固定化時間對Vero細胞生長的影響------ 23 三 細胞接種量對Vero細胞生長的影響-------------- 24 四 生物反應器培養系統對Vero細胞生長的影響------ 25 五 新鮮培養基更換對Vero細胞生長的影響---------- 27 六 最適化細胞生長條件培養日本腦炎病毒---------- 29 第五章 結論與建議---------------------------------- 30 參考文獻 -------------------------------------------- 31 附錄一 PBS配製方法--------------------------------- 62 附錄二 Medium 199配製方法-------------------------- 62 附錄三 MEM medium配製方法-------------------------- 62
222

BTEX: Desenvolvimento de barras de extração sortiva, determinação em efluente hospitalar e degradação por meio de fotocatálise heterogênea com TiO2 suportado em polímeros / BTEX: Development of bars sorptive extraction, determination in hospital effluent and degradation by heterogeneous photocatalysis with TIO2 supported in polymers

Silva, Daiane Skupin da 24 February 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / In this work were developed low cost bars of sorptive extraction, using commercial adhesive based on polydimethylsiloxane (PDMS) for the preconcentration and determination of benzene, toluene, ethylbenzene and xylene (BTEX) in effluent from the University Hospital of Santa Maria (HUSM). It was applied multivariate fractional factorial design (26-2) to investigate the significance of the independent variables for the sorptive extraction of BTEX. The best conditions in aqueous solution and in hospital effluent were: 25 °C and 15 min of adsorption, 35 °C and 30 min of desorption, pH 9. Thus, in aqueous solution it was obtained recovery rates of BTEX between 72.2 74.0%, with RSD between 5.4 and 6.4%, while, for hospital effluent spiked with the analytes, the recovery rates ranged around 72.0 74.8% with RSD between 4.68 and 5.62%. The concentrations of benzene, toluene, ethylbenzene and xylene found in the effluent of HUSM were, respectively: 1.2 μg L-1 (RSD 4.6%), 10.4 μg L-1 (RSD 2.1%), 1.7 μg L-1 (RSD 4.4%), 15.8 μg L-1 (RSD 3.5%). The use of bars of sorptive extraction of PDMS have been eliminated the morose stage of vacuum filtration of the effluent and allowed the determination of volatile compounds as BTEX by HPLC-FLD, which to the best of our knowledge, there are not reported in the literature yet. As remediation methodology was applied oxidative processes, heterogeneous photocatalysis and direct photolysis, it was used a stirred tank reactor with thermostatic jacket. Ultraviolet radiation (UV) was generated by mercury vapor lamp medium pressure, 125 W and 401 W m-2. Polymer bars were prepared with polydimethylsiloxane (PDMS) or polyurethane (PU) and TiO2 supported in order to evaluate the degradation of BTEX in aqueous solution and in effluent hospital by heterogeneous photocatalysis. The polymer bars were tested in the absence of UV radiation and the results showed that the analytes do not adsorb themselves in a irreversible way, in both kinds of polymer bars, which could mask the photodegradation. The overall efficiency of the system with TiO2 immobilized, for samples of effluent, is higher than with TiO2 in suspension (and for direct photolysis). To the aqueous solution, fully transparent, the direct photolysis showed better efficiency in the degradation of BTEX. The best conditions for the factorial design (33-1) to the complete degradation of BTEX in aqueous solution were: 20 °C, pH 5 and photolysis (irradiation without TiO2 polymer bars). For hospital effluent in wastewater spiked with the analytes the best conditions were: 20 °C, pH 9 and the use of irradiation with PDMS/TiO2 bars. At 120 min of irradiation it happens the degradation of 100% for all analytes, but the reduction of Chemical Oxygen Demand (COD) was around 25% in hospital effluent. Using a stirred tank reactor, with benzene as a model compound, in toxicity tests with the bioindicator Artemia salina, the reduced of LC50 was 65% compared with the LC50 of the effluent without treatment. / Neste trabalho foram desenvolvidas barras de extração sortiva, de baixo custo, utilizando-se adesivo comercial à base de polidimetilsiloxano (PDMS), para pré-concentração e determinação de benzeno, tolueno, etilbenzeno e xileno (BTEX) no efluente do Hospital Universitário de Santa Maria (HUSM). Para investigar as variáveis independentes significativas na extração sortiva de BTEX aplicou-se planejamento fatorial fracionado (26-2). As melhores condições obtidas, em solução aquosa e em efluente hospitalar foram: 25 °C e 15 minutos de adsorção; 35 °C e 30 minutos de dessorção; pH 9. Desta forma, obtiveram-se taxas de recuperação de BTEX em solução aquosa entre 72,2 74,0% com desvio padrão relativo (RSD) entre 5,5 6,5%. Já para o efluente hospitalar fortificado com os analitos, as taxas de recuperação variaram em torno de 71,9 74,8% (RSD 4,7 5,6%). As concentrações de benzeno, tolueno, etilbenzeno e xileno encontradas no efluente do HUSM foram, respectivamente: 1,2 μg L-1 (RSD 4,6%); 10,4 μg L-1 (RSD 2,1%); 1,8 μg L-1 (RSD 4,4%); 15,9 μg L-1 (RSD 3,5%). O emprego de barras suspensas de PDMS dispensa a etapa morosa de filtração à vácuo do efluente e permitiu que compostos voláteis como BTEX pudessem ser determinados diretamente por HPLC-FLD, o que, no melhor de nosso conhecimento, não tem ainda registro na literatura. Como metodologia de remediação aplicou-se processos oxidativos, fotocatálise heterogênea e fotólise direta, empregando-se reator tanque agitado com jaqueta termostática. A radiação ultravioleta (UV) foi gerada por lâmpada de vapor de mercúrio de pressão média, 125 W e 401 W m-2. Barras poliméricas, com polidimetilsiloxano (PDMS) ou poliuretano (PU), e TiO2 suportado foram preparadas a fim de avaliar a degradação de BTEX em solução aquosa e em efluente hospitalar por meio de fotocatálise heterogênea. As barras poliméricas foram testadas na ausência de radiação UV e os resultados demonstraram que os analitos não são adsorvidos de maneira irreversível, em ambos os tipos de barras poliméricas, o que poderia mascarar a fotodegradação. A eficiência global do sistema com TiO2 imobilizado, para amostras de efluente, é maior que com TiO2 em suspensão (e, maior ainda que na fotólise simples). Para a solução aquosa, totalmente transparente, a fotólise direta apresentou maior eficiência na degradação de BTEX. As melhores condições, do planejamento fatorial (33-1), para a degradação completa de BTEX em solução aquosa foram: 20 °C, pH 5 e fotólise direta (irradiação sem barras poliméricas com TiO2). Em efluente hospitalar fortificado com os analitos as melhores condições foram: 20 °C, pH 9 e irradiação com uso de barras de PDMS/TiO2. Em 120 min de irradiação ocorre a degradação de 100%, para todos os analitos, porém a redução da DQO ficou em torno de 25%, em efluente hospitalar. Utilizando o reator tanque agitado e tendo benzeno como composto modelo, nos testes de toxicidade com o bioindicador Artemia salina, a redução da LC50 foi de 65% comparada com a LC50 do efluente sem tratamento.
223

Modelagem e simulação dinâmica de reatores de leito fixo

Rodrigues, Caroline 25 February 2011 (has links)
Made available in DSpace on 2016-06-02T19:56:42Z (GMT). No. of bitstreams: 1 3506.pdf: 2271432 bytes, checksum: fc1d05123fb3be32395a9e84b2da5ad8 (MD5) Previous issue date: 2011-02-25 / Universidade Federal de Sao Carlos / This work investigated numerical methods in the solution of mathematical models of fixed-bed reactors. For the reactors modeling and simulation, two numerical methods were used: sequencing method (SM) and finite volume method (FVM). There were also proposed two mathematical models: the pseudo-homogeneous model and the dimensionless one, which is based on the Peclet (Pe) and Biot (Bi) numbers. A horizontal-flow anaerobic immobilized sludge (HAIS) reactor developed in bench scale and after a scale-up, reducing the COD in the wastewater treatment was simulated by sequencing method, varying the numbers of mesh; a tubular fixed-bed reactor with biomass immobilized for the startup period of lactic acid fermentation, also simulated by sequencing method and compared with experimental data; and was also evaluated the precision of sequencing and finite volume methods over the reactor s profile, varying the Peclet e Biot numbers. The models development was based on studies about hydrodynamics and biochemistry kinetics. Both methods described satisfactorily the behavior of the reactors in the performed simulations, but in high values of Peclet, the finite volume method generated inadequacies such as oscillatory responses and over the limit. This paper is an elucidation to sequencing method, which besides its huge range and simplicity, still is not so studied neither known, because it s a recent method. / Este trabalho investigou metodos numericos na solucao de modelos matematicos para reatores de leito fixo. Para a modelagem e simulacao dos reatores, foram utilizados dois metodos numericos: metodo da sequencia (SM) e metodo dos volumes finitos (FVM). Foram propostos dois modelos matematicos: o pseudo-homogeneo e o adimensional, sendo este ultimo baseado nos numeros de Peclet (Pe) e Biot (Bi). Um reator anaerobio horizontal de leito fixo (RAHLF) desenvolvido inicialmente em escala de bancada e posterior aumento de escala na reducao da DQO de aguas residuarias foi simulado pelo metodo da sequencia, variando-se o numero de malhas; um reator tubular de leito fixo com biomassa anaerobia imobilizada no periodo da partida da fermentacao de acido latico, tambem simulado pelo metodo da sequencia e comparado com dados experimentais; e avaliou-se a precisao dos metodos da sequencia e dos volumes finitos sobre o perfil da concentracao de um reator, variando-se os valores de Peclet e Biot. O desenvolvimento dos modelos foi baseado em estudos sobre caracteristicas hidrodinamicas do sistema e de cinetica bioquimica. Ambos os metodos descreveram satisfatoriamente o comportamento dos reatores nas simulacoes realizadas, porem em valores elevados de Peclet, o metodo dos volumes finitos gerou inadequacoes como respostas oscilatorias e superiores ao limite. Este trabalho foi uma elucidacao ao metodo da sequencia, que apesar da sua grande abrangencia e simplicidade, por ser um metodo recente, ainda e pouco estudado e conhecido.
224

Tratamento de água residuária com alta concentração de lipídios em reatores anaeróbios e em sistema de reatores combinados, enzimático-biológico / Lipid-rich concentration wastewater treatment in anaerobic reactors in a combined enzymatic-biologic reactors system

Douglas José da Silva 23 April 2004 (has links)
Este trabalho teve por objetivo investigar a degradação de lipídios em três sistemas anaeróbios de tratamento: um reator anaeróbio de fluxo horizontal de leito fixo (RAHLF) , um sistema combinado composto por um reator enzimático de leito expandido invertido (RELI) seguido por um RAHLF e um reator anaeróbio de manta de lodo (UASB). Os sistemas foram monitorados em uma câmara com temperatura controlada a 30,0 ± 0,5°C e alimentados com substrato sintético a base de lipídios, com concentração, em termos de demanda química de oxigênio (DQO) de 8748 ± 711 mg/L e concentração de óleos e graxas de 1820 ± 512 mg/L, O reator RAHLF foi operado com tempo de detenção hidráulica (TDH) de 24 horas por 100 dias e apresentou eficiências médias de remoção de DQO e de lipídios de 98,9 ± 0,4% e 94,9 ± 3,2%, respectivamente. O sistema combinado (reator enzimático / reator anaeróbio) apresentou eficiências médias de remoção de DQO e de lipídios de 99,0 ± 0,3% e 94,2 ± 2,8%, respectivamente, operado com TDH de 30 min no reator enzimático e 24 h no reator microbiológico. Posteriormente, o reator RAHLF foi submetido à diminuição do TDH de 24 para 8 h. As eficiências médias de remoção de DQO e lipídios foram de 87,0 ± 3,2% e 90,5 ± 2,7% verificadas para o menor TDH aplicado (8 h). O modelo cinético baseado em reações paralelas e em série, de primeira ordem, indicaram que a velocidade de reação aumenta com o aumento da velocidade superficial no reator RAHLF. Este comportamento pode ser atribuído à diminuição contínua da resistência à transferência de massa da fase líquida. O reator UASB apresentou baixa eficiência devido à flotação de 85% da manta de lodo granular, após 18 dias de operação. Os resultados obtidos neste trabalho permitem concluir que o reator RAHLF pode ser utilizado como unidade única no tratamento de efluentes com alta concentração de lipídios, devido a ter apresentado performance similar à observada no sistema integrado enzimático-anaeróbio. / The aim of this work was the investigation of the lipid degradation in three anaerobic treatment systems: a horizontal-flow anaerobic immobilized biomass (HAIB) reactor, a combined system composed by an inverted expanded-bed enzymatic reactor (EIBE) followed by a HAIB reactor and an up-flow anaerobic sludge blanket (UASB) reactor. The systems were monitored in a chamber under controlled temperature of 30 ± 0.5°C and fed with lipid-based synthetic wastewater, with chemical oxygen demand (COD) of 8748 ± 711 mg/L and 1820 ± 512 mg/L of oil and grease concentration. The HAIB reactor was operated with hydraulic detention time (HDI) of 24 hours for 100 days and it presented average COD and lipids removal efficiencies of 98.9 ± 0.4% and 94.9 ± 3.2%, respectively. The combined system (enzymatic/anaerobic reactors) presented COD and lipids removal efficiencies of 99.0 ± 0.3% and 94.2 ± 2.8%, respectively, operating with a HDI of 30 min in the enzymatic reactor and 24 h in the microbiological one. Afterwards, the HAIB reactor was subjected to decreasing HDI values from 24 to 8 h. Average COD and the lipids removal efficiencies of 87.04 ± 3.2% and 90.5 ± 2.7%, respectively, were achieved for the lower HDI applied (8 h). A kinetic model, based on first-order series and parallel reactions, indicated that the lipids reaction rate increased as the liquid superficial velocity was increased in the HAIB reactor, since the liquid-phase mass transfer resistance decreased continuously. The UASB reactor presented a poor performance, presenting flotation of the 85% of the granular sludge bed after 18 days of operation. The results obtained in this work permit the potential indication of HAIB reactor as the sole unit to treat lipid-rich wastewater, since the performance of the HAIB reactor was similar to that observed for the integrated hydrolytic-anaerobic system.
225

Comparação entre analisadores com fluxo constante ou pulsado: aplicação a amostras de relevância farmacêutica, agronômica e/ou ambiental / Comparison of flow analyzers exploiting constant or pulsed flows: application to samples of pharmaceutical, agronomical and/or environmental relevance

Milton Katsumi Sasaki 24 November 2015 (has links)
Sistemas de análises químicas em fluxo com multi-impulsão empregam bombas solenoide como unidade propulsora de fluidos, as quais proporcionam fluxos pulsados. Estes provêm um eficiente transporte radial de massas, o que garante boa homogeneização das soluções envolvidas, mesmo em situações de dispersão limitada. O objetivo principal deste trabalho foi então comparar o desempenho de metodologias envolvendo reagentes imobilizados em sistemas de análises em fluxo com fluxos constantes ou pulsados. Para isto, foram selecionadas as determinações espectrofotométricas de ácido ascórbico em produtos farmacêuticos, utilizando reator tubular de polietileno (50 cm) com MnO2(s) imobilizado, e reação com formaldoxima (0,25 mol L-1); e de carbaril em águas naturais, explorando extração líquido-líquido com xileno imobilizado em membrana de PVDF, e solução de NaOH a 0,1 mol L-1 como fluxo aceptor. Adicionalmente, compararam-se os dois tipos de fluxo em uma nova titulação em fluxo, a titulação monitorada por traçador; a determinação de acidez total em vinagres foi selecionada e utilizaram-se as titulações por injeção em fluxo e programada em triângulo, ambas empregando solução de NaOH a 0,01 mol L-1 como titulante e fenolftaleína como indicador ácido-base, com monitoramento por traçador empregando azul brilhante FCF (ca. 6 mg L-1). Na determinação de ácido ascórbico, o desempenho do sistema com fluxos pulsados foi superior àquele com fluxos constantes quanto ao limite de detecção: 0,33 contra 0,60 mg L-1 (critério 3,3 ?), e à repetibilidade: d.p.r. estimado como 2,5 contra 5,6% (n = 20); quanto à exatidão, não foi encontrada diferença estatisticamente significativa entre o método proposto e o da Farmacopeia Britânica ao nível de confiança de 95%. Na determinação de carbaril, o uso de fluxos pulsados favoreceu a extração do analito, obtendo-se uma sensibilidade 9,3% maior relativamente ao emprego de fluxos constantes, além de uma melhor linearidade da curva analítica; entretanto, o método mostrou-se susceptível a interferência de outros metilcarbamatos, o que comprometeu sua aplicação à análise de águas naturais. Na determinação de acidez total, a exploração de fluxos pulsados proporcionou menores variações da razão dos valores de absorbância relativos ao monitoramento do traçador e do indicador; não foi encontrada diferença estatística entre as titulações em fluxo propostas e o método titulométrico de referência ao nível de confiança de 95% / Multi-pumping flow systems use solenoid pumps as fluid propelling devices, which deliver pulsed flows. These flows provide an efficient radial mass transport, thus good mixing conditions even in limited sample dispersion situations. The main objective of this work was then to compare the performance of methodologies involving immobilized reagents in flow systems with constant or pulsed flows. To this end, the spectrophotometric determinations of ascorbic acid in pharmaceutical products using a 50-cm polyethylene tubular reactor with immobilized MnO2(s) with further colour-forming reaction with 0.25 mol L-1 formaldoxime; and carbaryl in natural waters exploiting liquid-liquid extraction with xylene immobilized in a PVDF membrane and a 0.1 mol L-1 ¬¬NaOH solution as acceptor stream, were selected. Moreover, constant and pulsed flows were compared in relation to a novel strategy for flow titration, named tracer-monitored titration; the determination of total acidity in vinegars was selected and flow injection and triangle-programmed titrations were applied, both using a 0.01 mol L-1 NaOH solution as titrant, phenolphtalein as acid-base indicator and ca. 6 mg L-1 brilliant blue FCF as tracer. Regarding ascorbic acid determination, the pulsed flow system was superior in relation to the constant flow system for detection limit: 0.33 against 0.60 mg L-1 (3.3 ? criterion), and for repeatability: r.s.d. estimated as 2.5 against 5.6% (n = 20); in relation to accuracy, no significant differences between the proposed method and that of the British Pharmacopoeia were found at the 95% confidence level. Regarding carbaryl determination, use of pulsed flows favored the analyte extraction, leading to a 9.3% sensitivity improvement in relation to use of constant flows; besides the attainment of better linearity of the analytical curve. The method was however susceptible to interference of other methylcarbamates, thus the application to natural water analyses was impaired. Regarding total acidity determination, pulsed flows exploitation provided lower variations in the ratio of absorbance values related to the monitoring of tracer and indicator; no significant differences between the proposed titrations and the reference method were found at the 95% confidence level
226

Tratamento de água residuária parcialmente solúvel em reator anaeróbio em batelada seqüencial contendo biomassa imobilizada e agitação mecânica: análise da influência da intensidade de agitação e do tamanho de biopartícula / Treatment of partially soluble wastewater in an anaerobic sequencing batch reactor with immobilized biomass and mechanical stirring: analysis of the influence of agitation rate and bioparticle size

Samantha Cristina de Pinho 09 June 2004 (has links)
Neste trabalho de doutorado utilizou-se um reator anaeróbio em batelada seqüencial contendo biomassa imobilizada em matrizes cúbicas de espuma de poliuretano e agitação mecânica, com volume total de 5.5 L e volume útil de 4.5 L. A agitação do meio líquido foi realizada com quatro tipos de impelidores (turbina tipo hélice, lâminas planas, lâminas planas inclinadas e lâminas curvas, testados individualmente, sempre em número de 3), com 6 cm de diâmetro. A pesquisa foi realizada em quatro etapas experimentais. A etapa 1 objetivou determinar o tempo de mistura no reator para cada tipo de impelidor, ou seja, o tempo necessário para que o meio líquido ficasse totalmente homogêneo. A etapa 2 objetivou selecionar o tipo de impelidor e a respectiva intensidade de agitação que garantisse a minimização da resistência à transferência de massa externa no sistema. As intensidades de agitação testadas variaram de 200 a 1100 rpm, dependendo do tipo de impelidor. A etapa 3 foi realizada com tipo de impelidor e intensidade de agitação definidos na etapa 2, mas variando-se o tamanho da biopartícula (0,5, 1,0, 2,0 e 3,0 cm de aresta). O objetivo desta etapa foi selecionar o tamanho de biopartícula que minimizasse a resistência à transferência de massa interna. De posse das condições operacionais otimizadas (tipo de impelidor, intensidade de agitação e tamanho de partícula de suporte), a etapa 4 constituiu na aplicação das mesmas para o tratamento de um resíduo real, sendo escolhida água residuária de suinocultura. Na etapa 1, os resultados mostraram que os tempos de mistura para todos os tipos de impelidores foram desprezíveis em relação ao tempo total de ciclo. A etapa 2 revelou tempos de partida muito curtos (cerca de 20 dias), em todas as condições testadas, sendo atingidas remoções de DQO próximas de 70%. Além disso, o tipo de impelidor exerceu grande influência na qualidade final do efluente, fato este claramente constatado quando as frações de DQO foram consideradas separadamente (filtrada e suspensa). De acordo com os resultados obtidos na etapa 3, o tamanho da biopartícula teve influência decisiva no desempenho do sistema, nas condições testadas. As velocidades de dissolução foram aparentemente influenciadas pelo empacotamento do leito de espuma, enquanto que o consumo da fração de DQO correspondente às amostras filtradas foi provavelmente influenciado por fatores mais complexos. Finalmente, o teste realizado com resíduo diluído de suinocultura demonstrou que a operação do reator em estudo para o tratamento deste tipo de água residuária é possível. Os dados operacionais mostraram que o reator permaneceu estável durante o período testado. A agitação mecânica provou ser eficiente para melhorar a degradação da DQO suspensa, um dos maiores problemas no tratamento deste tipo de água residuária. Sendo assim, de acordo com os dados experimentais obtidos ao longo do trabalho, pode-se afirmar que a agitação em reatores em batelada mostrou-se importante não somente para proporcionar boas condições de mistura ou melhorar a transferência de massa na fase líquida, mas também para melhorar a solubilização da matéria orgânica particulada, melhorando as velocidades de consumo de matéria orgânica. / The bench-scale anaerobic sequencing batch reactor containing immobilized biomass and provided with mechanical stirring employed in this work had total and useful volumes of 5.5 and 4.5 L, respectively. The biomass was immobilized on cubic polyurethane foam matrices, and the agitation of the liquid medium was provided by four types of impellers (propeller, flat-blade, pitched-blade and curved-blade turbines, individually tested, always in a set of three), with 6 cm of diameter. The research was divided into 4 experimental steps. The first one aimed at determining the mixing time in the reactor for each sort of impeller, i.e., the time necessary for the system to be completely homogeneized. As for the second step, its objective was to choose the sort of impeller and the agitation rate suitable for minimizing the external mass-transfer resistance. The agitation rates tests ranged from 200 to 1100 rpm, depending on the impeller type. The step 3 was carried out utilizing the chosen impeller and agitation rate, but varying the bioparticle size (0.5, 1.0, 2.0 and 3.0 cm of side). The aim of these experiments was to determine the bioparticle size that minimized the solid-phase mass transfer. Using these optimized operational conditions (type of impeller and bioparticle size), the step 4 consisted of the utilization of them in the treatment of a real wastewater (diluted swine manure). As for the results, step 1 showed the mixing times were very low compared to the total cycle times employed in the experiments (8 and 24 h). Very short start-up periods were revealed by the second experimental part (about 20 days in average) for all conditions tested, and the removal efficiencies reached approximately 70%. Besides that, the impeller type exerted great influence on the final quality of the effluent, fact clearly observed when the COD fractions were analyzed separately (filtered and suspended). According to the data obtained in the step 3, the bioparticle size influenced decisively on the performance of the system, in the conditions tested. The bed packing apparently influenced the dissolution rates, whereas the consumption of the COD correspondent to the filtered samples was defined by more complex factors. Finally, the test with the diluted swine manure demonstrated that the operation of this reactor with this type of wastewater is feasible, as the operational data showed the reactor remained stable during all the period tested. The mechanical stirring proved to be efficient to improve the degradation of the suspended COD, one of the major problems in the treatment of this type of wastewater. In this sense, according to the experimental data obtained in this work, it can be affirmed the mechanical stirring in anaerobic sequencing batch reactors showed to be not only important to provide good mixing conditions and improve the liquid phase mass transfer, but also to improve the solubilization of the particulate organic matter and increase the overall organic matter consumption rates.
227

Avaliação da recirculação da fase líquida e do regime de alimentação no reator anaeróbio, em escala piloto, operado em bateladas seqüenciais contendo biomassa imobilizada (ASBBR), no tratamento de esgoto sanitário / Influence of the liquid phase recirculation and the feeding regimen on a pilot anaerobic immobilized biomass sequencing batch reactor treating domestic sewage

Katt Regina Lapa 19 December 2006 (has links)
Avaliou-se a influência da recirculação da fase líquida e do regime de alimentação em reator anaeróbio no tratamento de esgoto sanitário. Utilizou-se um reator anaeróbio operado em bateladas seqüenciais, contendo biomassa imobilizada (ASBBR), em escala piloto, com volume total de 1,2 \'M POT.3\' (\'fi\' 1,0 m e altura 1,53 m). O leito suporte para a imobilização da biomassa era constituído por matrizes cúbicas de espuma de poliuretano, com 5 cm de aresta, confinadas em cesto de aço inox 304, colocado no interior do reator. A influência da recirculação da fase líquida sobre o desempenho do ASBBR quanto à remoção de matéria orgânica e quanto ao arraste de sólidos foi avaliada submetendo-se o reator às velocidades ascensionais de 1,27; 3,82; 7,64 e 10,18 m/h resultantes das diferentes vazões de recirculação impostas. Contrariamente ao observado em pesquisas anteriores em reatores operados em escala de bancada e alimentados com água residuária sintética, não houve aumento significativo da eficiência do reator com o aumento da velocidade ascensional no tratamento de esgoto sanitário. A influência do regime de alimentação de esgoto sanitário no desempenho do ASBBR foi avaliada submetendo-se o reator a tempos de enchimento correspondentes a 0,25 e 0,5 do tempo total de ciclo, utilizando-se a vazão de recirculação de 6 \'M POT.3\'/h, que foi a que apresentou os melhores resultados nos ensaios anteriores. Concluiu-se que o reator pode ser operado sob batelada alimentada com duração de até 0,5 tempo de ciclo, sem que seu desempenho seja significativamente alterado. Esse resultado é importante, pois representa que o sistema de tratamento composto por reatores ASBBR pode ser projetado com número menor de reatores. A fim de esclarecer dúvidas sobre o desempenho do ASBBR observado no tratamento de água residuária de composição complexa (esgoto sanitário), o reator foi alimentado com água residuária facilmente degradável (etanol). O desempenho do reator foi aquém do esperado, mesmo quando alimentado com composto de fácil degradação. Os ensaios de atividade metanogênica específica (AME) demonstraram que houve decréscimo dos valores de AME com o aumento da velocidade ascensional. Os valores obtidos foram 0,0632; 0,0509; 0,0248 e 0,0299 g DQO-CH4/(g STV.d), respectivamente, para os valores de Va de 1,27; 3,82; 7,64 e 10,19 m/h. Concluiu-se que a baixa eficiência de remoção de matéria orgânica deveu-se ao abaixamento progressivo da atividade metanogênica do lodo, cujas causas não puderam ser completamente esclarecidas nesta pesquisa. / The influence of the liquid phase recirculation and the feeding regimen on the performance of an anaerobic sequencing batch reactor containing immobilized biomass (ASBBR) applied for the treatment of domestic sewage was evaluated. Biomass immobilization was provided by a basket containing cubic polyurethane foam matrices (5 cm side) inside the 1.2 \'M POT.3\' (1.0 m diameter and 1.53 m height) pilot-scale reactor. The influence of the liquid phase recirculation on the reactor performance in respect to organic matter and solids wash-out was verified by subjecting the reactor to a wide range of up flow velocities (1.27; 3.82; 7.64 and 10.18 m/h) resulting from different recirculation flow rates imposed. The increase of the up flow velocity did not increase the efficiency of the pilot reactor as expected. This result contradicts those obtained with bench-scale ASBBR experiments treating synthetic wastewaters. The influence of the feeding regimen was verified by subjecting the reactor to feeding times correspondent to 0.25 and 0.50 of the total cycle time, at the recirculation flow rate of 6 \'M POT.3\'/h. It could be concluded that the reactor can be operated at the feeding batch mode up to 0.5 of the cycle time. This result is important for full scale applications considering that a treatment system composed of ASBBR reactors can be designed using a lower number of units. In order to clear some aspects related to the limited performance of the ASBBR reactor treating a complex wastewater (sewage), the reactor was subjected to an easily degradable wastewater (ethanol). However, the performance was not improved even when the reactor was treating an easily degradable compound. The results from the specific methanogenic activity (SMA) demonstrated a decrease on the values of SMA with the increase of the up flow velocity. The values of SMA were 0.0632; 0.0509; 0.0248 and 0.0299 g DQO-CH4/(g STV.d) for the Va of 1.27; 3.82; 7.64 and 10.19 m/h respectively. It could be concluded that the low efficiency obtained for organic matter removal was due mainly to the progressive decrease of the sludge methanogenic activity. The causes for that behaviour could not be completely explained in this research. It could be concluded that the reactor performance was iv clearly limited by the low productivity of the methanogenic populations present in the biomass.
228

Efeitos da temperatura e velocidade superficial em sistema anaeróbio de duas fases tratando esgoto sanitário sintético em reatores horizontais com células imobilizadas / not available

Marcio Gomes Barboza 20 September 2002 (has links)
Este trabalho investigou o efeito da temperatura nos sistemas aneróbios com células imobilizadas tendo como estudo de caso um sistema anaeróbio em duas fases. Inicialmente, foram realizados experimentos preliminares com um sistema em duas fases composto por Reator Acidogênico Horizontal Tubular (RAHT) seguido de Reator Anaeróbio Horizontal de Leito Fixo (RAHLF), nas temperaturas de 15ºC, 20ºC e 25ºC. Os resultados mostraram que o RAHT alcançou 48% de remoção de DQO e que a desvantagem da ausência de microrganismos consumidores de H2 no sistema praticamente não afetou a produção de ácido acético. Pôde-se observar que na faixa de temperatura estudada o RAHT não apresentou mudanças significativas em seu desempenho. Posteriormente foram realizados experimentos com cinco reatores metanogênicos do tipo RAHLF, alimentados com esgoto sintético simulando o efluente do RAHT, com velocidades de 10,4 cm/h, a 52,0 cm/h e temperatura de 15ºC a 35ºC. Os resultados permitiriam o desenvolvimento de um modelo empírico-estatístico para simulação do desempenho dos reatores, tendo como variáveis a velocidade superficial do líquido sobre as biopartículas e a temperatura de operação. Os resultados preditos pelo modelo demonstraram boa representatividade dos valores experimentais. Com isso, foi possível observar as influências da velocidade superficial (vs) e da temperatura, nas concentrações residuais de substrato (Sr) e nas constantes cinéticas aparentes de primeira ordem (K1app). Conclui-se então, que apesar do aumento de vs resultar em maiores valores de K1app, também foi observado aumento no valor de Sr indicando que existe um tempo de contato mínimo entre os microrganismos e o substrato. / The effects of temperature and superficial velocity in an anaerobic methanogenic immobilized cell rector of a two phase-system were investigated. Preliminarily, a Tubular Horizontal Acidogenic Reactor (THAR) followed by Horizontal-flow Anaerobic Immobilized Biomass (HAIB) composed the experimental system, operated at the temperatures of 15°C, 20°C and 25°C. COD removal efficiency of 48% was observed in the THAR. Likewise, the disadvantage of the absence of H2-consumer methanogenics microorganisms in the system almost did not affect the production of acetic acid. The temperature variation has not caused significant changes in the THAR performance. The next step was the development of experiments using five methanogenics HAIB reactors fed on synthetic wastewater simulating THAR effluent having superficial velocities from 10,4 cm/h to 52,0 cm/h and temperature from 15°C to 35°C. The results enabled the development of a statistical-empiric modeling to simulate the reactors performance using the liquid superficial velocities and the temperature operation as model variables. The model demonstrated a good agreement with the experimental values. The influence of the superficial velocities (vs) and temperature, in the substrate residual concentration (Sr) and in the first order (K1app) apparent kinetic constant was observed. Despite the K1app values have increased largely with vs, the Sr concentration also increased. These results permit to conclude that a minimum contact time between the microorganisms and the substrate may be necessary in such processes.
229

Multifunctional and Stimuli-Responsive Polymersomes for Biomedical Applications

Iyisan, Banu 16 January 2017 (has links) (PDF)
The demand for multifunctional nanocontainers possessing both recognition ability and responsive nature is increasing greatly because of their high potential in various biomedical applications. The engineering of such smart nanovesicles is useful to enhance the efficiency of many therapeutic and diagnostic tools that have the applicability in targeted drug delivery systems as well as designing sensing devices or conducting selective reactions as nanoreactors in the scope of nanobiotechnology. For this purpose, this study demonstrates the formation of multifunctional and stimuli-responsive polymersomes comprising various abilities including pH and light sensitivity as well as many reactive groups with sufficient accessibility to be used as smart and recognitive nanocontainers. The fabrication included several steps starting from the synthesis of azide and adamantane terminated block copolymers, which were then self-assembled to prepare the polymersomes with the corresponding functional groups for the subsequent post-conjugations at the vesicle periphery. The accessible and sufficiently reactive groups were quantitatively proven when UV and IR cleavable NVOC protected amino groups as well as β-cyclodextrin molecules were conjugated to the pre-formed polymersomes through click chemistry and strong host-guest complexations. The gained light responsivity with the aid of successful NVOC attachment enabled further selective photochemical reactions triggered either by UV or NIR light leading to liberated amine groups on the polymersome surface. Therein, these released amino groups were further conjugated with a model fluorescent compound as mimicking the attachment of biorecognition elements to see the direct picture of the applicability. To realize this concept in a more localized and selective way as well as to avoid the possible side effects of UV light, the NIR-light induced photochemical reactions and further dye coupling were performed when polymersomes were immobilized onto solid substrates. This fixation was achieved by adapting the host-guest chemistry into this part and conjugating the adamantane decorated polymersomes onto β-cyclodextrin coated substrates. Several investigations including adhesion behavior, pH sensitivity and mechanical properties of the established multifunctional polymersomes under liquid phase have been performed. It has been found that the polymersome shape is highly dependent on the attractive forces of the substrate and needs to be optimized to avoid the flattening of the vesicles. For these optimization steps, different conditions were investigated including the decrease of cyclodextrin amount and additional surface passivation with PEG molecules on the solid substrates. Besides, the calculated Young’s and bending modulus of the polymersome membrane from AFM measurements showed a robust but still flexible “breathable” membrane which is an important criterion for the applicability of these smart and stable vesicles. In addition, the hosting ability as well as diffusion limits and sufficient membrane permeability of the polymersomes were observed by encapsulating gold nanoparticles as a smart cargo and doxorubicin molecules as an anticancer drug. In conclusion, the established multifunctional polymersomes are highly versatile and thus present new opportunities in the design of targeted and selective recognition systems which is highly interesting for various applications including development of microsystem devices, design of chemo/biosensors, and also for conducting enhanced, combined therapy in the field of drug delivery.
230

Integração do tratamento microbiológico com células imobilizadas e tecnologias emergentes (Processos Oxidativos Avançados) para o tratamento de efluentes gerados na indústria têxtil. / Integration of microbiological treatment with immobilized cells and emerging (Advanced Oxidation Process) technologies for wastewater treatment generated in the textile industry.

Ivy dos Santos Oliveira 13 November 2009 (has links)
A integração de diferentes processos de tratamento na degradação de efluente têxtil foi avaliada utilizando-se a técnica de precipitação, processos oxidativos avançados (POA) e tratamento biológico aeróbio. Os POAs (Ozônio/UV e reagente de Fenton/UV) foram avaliados com experimentos em bateladas de acordo com um planejamento fatorial L18 (Método Tagushi) em função da vazão de ozônio, concentração de reagente Fenton, radiação UV, pH e temperatura. No tratamento microbiológico por processo contínuo, foi utilizado um reator de leito fluidizado com células imobilizadas de zeólitas e avaliados parâmetros como pré-tratamento com POAs, vazão de aeração, taxa de diluição. Concluiu-se que com o pré-tratamento físico-químico obteve-se resultados bastante satisfatórios na redução da DQO e COT, porém gerou uma quantidade desnecessária de lodo. A integração lodo ativado/Reagente Fenton mostrou-se bastante adequada, principalmente na remoção da cor e turbidez; a variedade e freqüência dos microrganismos observados durante o monitoramento biológico foram condizentes com os sistemas de lodo ativado operando eficientemente e o emprego de zeólitas como suporte mostrou-se significativo, alcançando 63,3 % de imobilização do microrganismo no suporte. / The integration of different treatment processes in the degradation of textile wastewater was evaluated using precipitation technique, advanced oxidation processes (AOP) and aerobic biological treatment. AOPs (Ozone/UV and reagent of Fenton/UV) were evaluated in batch experiments according to a factorial planning L18 (Tagushi Method) in function of the flow of ozone, concentration of reagent Fenton, UV radiation, pH and temperature. In the microbiological treatment for continuous process, a reactor of bed fluidized was used with immobilized cells of zeolites some parameters were evaluated such as pre-treatment with AOPs, aeration flow, diluition rate. Satisfactory results were obtained with the physical-chemistry pre-treatment in the reduction of COD and TOC, however it generated an unnecessary amount of sludge. The integration activated sludge/Reagent Fenton was shown quite appropriate, mainly in the removal of the color and turbidity; the variety and frequency of the microorganisms observed during the biological monitorament were suitable with the systems of activated sludge operating efficiently and the use of zeolites as support was shown significant, reaching 63,3 % of immobilization of the microorganism in the support.

Page generated in 0.0601 seconds