Spelling suggestions: "subject:"implante dentário"" "subject:"implante mentário""
61 |
Avaliação clínico-radiográfica e estabilidade implantar em overdenture mandibular retida por implante unitário / Clinical radiographic and implant stability evaluation of single implant-retained mandibular overdenturesNogueira, Túlio Eduardo 03 April 2014 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2015-03-02T14:42:20Z
No. of bitstreams: 2
Dissertação - Tulio Eduardo Nogueira - 2014.pdf: 2052325 bytes, checksum: a10ec63df3d099550385e5493ffd24d6 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-03-02T15:29:11Z (GMT) No. of bitstreams: 2
Dissertação - Tulio Eduardo Nogueira - 2014.pdf: 2052325 bytes, checksum: a10ec63df3d099550385e5493ffd24d6 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-03-02T15:29:11Z (GMT). No. of bitstreams: 2
Dissertação - Tulio Eduardo Nogueira - 2014.pdf: 2052325 bytes, checksum: a10ec63df3d099550385e5493ffd24d6 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2014-04-03 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / Objective: To conduct a longitudinal evaluation of marginal bone loss, peri-implant aspects and stability in single implant used to retain mandibular overdenture, and to evaluate outcomes related to the overdenture. Methods: Forty-five completely edentulous individuals were treated using mandibular overdenture retained by a single implant (Titamax IT Cortical, Neodent, Curitiba, Brazil) opposed to conventional dentures. According to the primary stability obtained in the implant placement patients were treated with an immediate loading protocol when torque was at least 30 Ncm and implant stability quotient (ISQ) at least 60. In cases of values below cited conventional loading protocol were adopted. O’Ring attachment system from two different commercially available companies were used and allocated systematically between subjects. Follow-up evaluations were performed immediately and at 3 and 6 months after implant placement, when parameters related to implant stability, periimplant tissue aspects, implant survival rate and need for the maintenance of the overdenture were noted. Results: 38 (84.4%) of 45 patients received immediate loaded implants. Implant failure occurred in 3 cases, 2 of them in the conventional loading group (early loss before implant loading). There was an increase in ISQ values in subsequent periods after implant placement, evidenced between baseline and 6 months (p=0.004) and between 3 and 6 months (p<0.001). The mean marginal bone loss at follow-up was 0.50 mm (SD=0.66). It was observed gradual reduction of the gingival height up to 6 months (p=0.006), as well as progressive reduction in plaque index (p=0.028) and bleeding on probing (p=0.021). There was no difference in clinical condition concerning the attachments that were compared. However, Neodent attachments showed better clinical performance and lower replacement rates (p=0.014). Conclusion: This clinical study suggested that the single implant-retained mandibular overdenture is a feasible treatment for mandibular edentulousness, showing favorable clinical and radiographic periimplant outcomes as well as maintenance of the implant stability. / Objetivo: Realizar avaliação longitudinal da perda óssea marginal, aspectos periimplantares e da estabilidade em implante unitário utilizado para retenção de overdenturs mandibular, além de avaliar desfechos relacionados às próteses. Métodos: Quarenta e cinco indivíduos desdentados totais foram tratados com overdenture mandibular retida por implante unitário em oposição a prótese total superior convencional. De acordo com a estabilidade primária obtida no momento de instalação do implante, os indivíduos foram tratados com protocolo de carregamento do implante imediato quando o torque final de instalação era de no mínimo 30 Ncm e o quociente de estabilidade implantar (ISQ) de no mínimo 60. Em casos de valores abaixo dos citados, era adotado o protocolo de carga convencional. Utilizou-se o sistema de retenção O’Ring de duas marcas comerciais, alocados sistematicamente entre os sujeitos. Os desfechos avaliados foram: estabilidade do implante, aspectos teciduais periimplantares e necessidade de manutenção das próteses. O acompanhamento foi realizado nos períodos imediato, 3 e 6 meses após instalação dos implantes. Resultado: Dos 45 pacientes, 38 (84,4%) receberam implante com carga imediata. Houve perda de 3 implantes, sendo 2 no grupo de carga convencional (perda antes do carregamento do implante). O valor médio de ISQ aumentou nos períodos subsequentes à instalação dos implantes, entre o período inicial e de 6 meses (p=0,004) e entre os períodos de 3 e 6 meses (p<0,001). A perda óssea marginal média no período de acompanhamento foi de 0,50 mm (DP=0,66). Foi observada redução progressiva da altura gengival até o período de 6 meses (p=0,006), resultado da acomodação dos tecidos periimplantares, bem como diminuição do índice de placa (p=0,028) e sangramento à sondagem (p=0,021). Não houve diferença na condição clínica em relação às marcas comerciais do sistema de retenção, porém a marca Neodent apresentou desempenho clínico superior com menor ocorrência de substituição da matriz de retenção e maior tempo até necessidade de substituição (p=0,014). Conclusão: O presente estudo clínico mostrou resultados satisfatórios do tratamento com overdenture mandibular retida por implante unitário em relação aos parâmetros clínicos e radiográficos, além da manutenção da estabilidade do implante.
|
62 |
Análise qualitativa e quantitativa, pelo método dos elementos finitos, da distribuição de tensão em diferentes rebordos reabilitados com próteses metalocerâmicas sobre implantes do tipo cone Morse, de diferentes comprimentos / Qualitative and quantitative analysis by finite element method of the stress distribution at different bony edges rehabilitated with Morse taper implant- supported metalloceramic prostheses, of different lengthsToniollo, Marcelo Bighetti 16 December 2011 (has links)
O emprego dos implantes osseointegráveis na odontologia moderna tem sido crescente. Dentre os tipos de conexões existentes, o cone Morse tem se mostrado com vantagens e atrativos interessantes. Com relação ao comprimento, a aplicabilidade de implantes curtos para casos de perda óssea vertical intensa se faz muito presente, principalmente em áreas mandibulares posteriores, a fim de se evitar procedimentos cirúrgicos mais complexos que envolvam maior morbidade. Juntamente com a perda óssea, a necessidade da manutenção do plano oclusal nivelado é inquestionável, sendo necessário o uso de próteses sobre implantes curtos com dimensões maiores, podendo haver sobrecarga sobre tais implantes e estruturas de suporte. O método dos elementos finitos (MEF) possibilitou avaliar as tensões na superfície dos implantes e componentes, e na interface entre implantes e rebordo ósseo. Neste estudo foram usados modelos de implantes cone Morse e próteses sobre implantes do tipo metalocerâmicas, individualizadas, de diferentes dimensões, alojados em diferentes rebordos com reabsorção óssea vertical. Todas as estruturas foram desenhadas por meio do programa SolidWorks (SolidWorks Corporation, Massachusetts, USA), e análises qualitativas e quantitativas das tensões equivalentes de Von Mises foram realizadas nos rebordos ósseos e implantes por meio do programa AnsysWorkbench10.0 (Swanson, Analysis Systems, Inc., Houston, USA). Os grupos foram: grupo controle (3 implantes de 11mm comprimento), grupo 1 (implantes de 13mm, 11mm e 5mm comprimento), grupo 2 (1 implante de 11mm e 2 implantes de 5mm comprimento) e grupo 3 (3 implantes de 5mm comprimento). As alturas dos pilares usados foram 3.5mm para implantes de 13mm e 11mm (regulares) e 0.8mm para implantes de 5mm (curtos). Foram simuladas forças oblíquas de 365N em molares e 200N em pré-molares. Os resultados mostraram que, com relação aos implantes e componentes, os pilares com 0.8mm de altura geraram menores tensões equivalentes de Von Mises comparativamente aos de 3.5mm de altura. A associação de implantes curtos com coroas de maiores dimensões concentrou maiores valores e distribuição de tensões na superfície destes implantes, principalmente na face vestibular (direção das cargas oblíquas). O implante mais distal sempre concentrou maiores tensões. Já com relação ao osso, houve 50% mais tensão no osso cortical para os implantes de 5mm do que os de 13mm e 11mm de comprimento. Houve 80% mais tensão no osso esponjoso para os implantes de 5mm do que os de 13mm e 11mm de comprimento. Houve maior concentração de tensão na região óssea cervical aos implantes curtos. No entanto, tais implantes foram capazes de realizar boa dissipação das tensões aos ossos frente às cargas aplicadas, apesar de atingir seu limiar próximo entre deformação elástica e plástica para o osso trabecular. Implantes mais distais e/ou com maior mesa oclusal geraram regiões de maior tensão no osso circunjacente. Concluiu-se que pacientes que se faz necessária a instalação de implantes curtos associados a próteses sobre implantes de dimensões aumentadas necessitam de cuidadosa avaliação e ajuste oclusal, já que uma eventual sobrecarga nestes implantes curtos, e até mesmo nos de comprimento regular, podem gerar tensões que vão além do limiar fisiológico do osso circunjacente, podendo acarretar danos a todo o sistema. / The use of dental implants is increasing in dentistry. Among the different types of connections existent, the Morse taper has been highlighted on several positive features. Regarding to the length, the use of short implants in cases of severe vertical bone loss are becoming frequent, especially in mandibular posterior areas, avoiding more complex surgical procedures and greater morbidity. As a consequence of bone loss, the need for rehabilitation to maintain the occlusal plane level is unquestionable, leading to the use of implants prostheses with larger dimensions, which may cause overload on these short implants and the supporting structure. This finite element analysis (FEA) compared stress distribution on external surface of Morse taper implants, their abutments and at bone/implant interface of different bone ridges, varying implants length and dimensions of each metal-ceramic crowns. All structures were designed using the SolidWorks software (SolidWorks Corporation, Massachusetts, USA), and qualitative and quantitative analysis of the equivalent Von Mises stresses were ran on AnsysWorkbench10.0 (Swanson Analysis Systems, Inc., Houston, USA). Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11mm length; group 1, implants of 13mm, 11mm and 5mm length; group 2, 1 implant of 11mm and 2 implants of 5mm length; group 3, 3 implants of 5mm length. The abutments heights were 3.5mm for 13mm and 11mm implants (regular) and 0.8mm for 5mm implants (short). Evaluation was performed on Ansys software, with oblique loads of 365N for molars and 200N for premolars. The results, for implants and abutments, showed that abutments with 0.8mm height generated less von Mises stresses compared with 3.5mm height. The use of short implants associated with bigger crowns concentrated higher stress distribution and stress values on the surface implants, mainly on the vestibular side (oblique loads). The more distal implants had the higher stress mesures. The results for the bone showed that there was 50% higher stress on cortical bone on the 5mm implants length than 13mm and 11mm implants. There was 80% higher stress on trabecular bone for the 5mm implants length than 13mm and 11mm implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable to dissipate the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, which may compromise the whole system.
|
63 |
Precisão das técnicas de moldagem e vazamento para próteses implantossuportadasDel'Acqua, Marcelo Antonialli [UNESP] 03 May 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-05-03Bitstream added on 2014-06-13T19:37:32Z : No. of bitstreams: 1
delacqua_ma_me_arafo.pdf: 2803470 bytes, checksum: c3da6f0cf6b27aff80e479e792d68cd7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo... / Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below)
|
64 |
Efetividade de parafusos com tratamento de superfície na estabilidade de pilares em zircônia após carga cíclicaBasílio, Mariana de Almeida [UNESP] 18 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-03-18Bitstream added on 2014-06-13T19:16:53Z : No. of bitstreams: 1
basilio_ma_me_arafo.pdf: 801760 bytes, checksum: 7941402e0f93534f3eda18455ce01460 (MD5) / Com o objetivo de prevenir o afrouxamento, parafusos do pilar com lubrificantes sólidos de superfície foram desenvolvidos e introduzidos no mercado. Assim, foi proposto avaliar a efetividade de parafusos de liga de titânio com e sem tratamento de superfície sobre a estabilidade de pilares em zircônia (ZrO2) após carga cíclica, bem como observar alterações estruturais por meio de microscopia eletrônica de varredura (MEV). Para isso, 20 pilares UCLA em ZrO2 foram fixados sobre implantes do tipo hexágono externo com torque de 20 Ncm e divididos em 2 grupos (n=10), conforme o parafuso do pilar: (A) pilar-implante e parafuso de liga de titânio (Ti); (B) pilar-implante e parafuso de liga de titânio com cobertura Diamond Like Carbon (DLC/Ti). O valor do torque reverso (pré-carga) foi mensurado antes e após o carregamento. O teste foi realizado de acordo com a norma ISO 14801. Cargas cíclicas (0,5 x 106; 15 Hz) entre 11 - 211 N foram aplicadas com 30º de inclinação em relação ao longo eixo dos implantes. As médias dos grupos foram calculadas e comparadas utilizando análise de variância de dois fatores e testes F (α=0,05). Os resultados mostraram que antes do carregamento a média do grupo Ti foi significativamente maior que a do grupo DLC/Ti (p=0,021). Após o carregamento ambas as médias 14 diminuíram significativamente, sem diferença significante entre elas (p=0,499). As imagens obtidas na MEV revelaram micro-fraturas na base de assentamento do pilar. Nas condições estudadas, concluiu-se que: (1) os parafusos estudados apresentaram efetividade similar com relação à manutenção da pré-carga; (2) a redução significativa no torque reverso e os danos observados na MEV indicam que o acompanhamento dos pacientes é necessário para assegurar a longevidade das restaurações de ZrO2 implanto-suportadas. / In an attempt to prevent screw-loosening problem, abutment screws with surface treatment were developed. Thus, the aim of the current study was to evaluate comparatively the effectiveness of titanium alloy coated screws and noncoated screws on the stability of ZrO2-ceramic abutments after cyclic loading, as soon as observe possible microdamaging in the structure of the components using a scanning electron microscope (SEM). For this, 20 prefabricated ZrO2-ceramic UCLA abutments were tightened to 20 Ncm on their respective external hex implants and divided equally into 2 groups (n=10), according to the type of screws used: (A) implant-abutment and noncoated titanium alloy screw (Ti); (B) implant–abutment and titanium alloy screw with Diamond Like Carbon surface coating (DLC/Ti). The reverse torque value (preload) of the abutment screw was measured before and after loading. The tests were performed according to ISO norm 14801. A cyclic loading (0,5 x 106; 15 Hz) between 11 - 211 N was applied at an angle of 30 degrees to the long axis of the implants. Group means were calculated and compared using ANOVA and F tests (α=0,05). The results showed that before cyclic loading, the mean of Ti group was significantly higher than the DLC/Ti group (p=0,021). After cyclic loading, both means decreased significantly, with no significant differences 16 between them (p=0,499). Under the studied conditions, it can be concluded that: (1) the two abutment screw types presented similar effectiveness in maintaining preload; (2) the significant decrease in reverse torque values and the microdamaging detected at SEM analysis indicate that patient follow-up is needed to ensure the integrity of the ZrO2-ceramic single-implant restorations.
|
65 |
Aderência in vitro de Streptococcus sanguinis e Candida albicans em implantes dentários de superfície lisa ou tratadaRomeiro, Rogério de Lima [UNESP] 14 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:55Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-07-14Bitstream added on 2014-06-13T19:22:47Z : No. of bitstreams: 1
romeiro_rl_dr_sjc.pdf: 889307 bytes, checksum: b97ee7a898e0c8f57f25ac75008f2fc8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse trabalho foi analisar in vitro a aderência de Streptococcus sanguinis, Candida albicans e associações destes microrganismos com Streptococcus mutans às superfícies dos implantes dentários tratados com jateamento de fosfato de cálcio, anodização, duplo ataque ácido e os de superfície lisa, com ou sem a prévia incubação em saliva ou plasma sanguíneo. Foram selecionados 120 implantes, sendo 30 de cada superfície para cada microrganismo e associações estudadas. Para análise da aderência, foram preparadas suspensões de microrganismos contendo 106 células/ml em espectrofotômetro. Além disso, cada microrganismo e associações foram divididos em três grupos: em um, o implante foi removido da embalagem e colocado diretamente no caldo, em outro, foi previamente embebido em saliva humana por uma hora e no último em plasma humano, também por uma hora. Os implantes foram acondicionados separadamente em poços de placas de cultura de células contendo caldo sacarosado (placa in vitro) e a suspensão do microrganismo. Após 24h de incubação a 37 °C e 5% de CO2, os implantes foram lavados três vezes durante um minuto em solução salina estéril e colocados em sonicador com 10 ml de salina para dispersão das células aderidas. A seguir, foram realizadas diluições seriadas e semeaduras em meios de cultura específico para cada microrganismo. Após 48h de incubação a 37 °C e 5% de CO2, foi realizada a contagem de unidades formadoras de colônias (UFC/ml) e os dados foram submetidos a análise de variância (ANOVA), teste de tukey, com nível de significância de 5%. Para ilustrar a aderência dos microrganismos, foram selecionados o microrganismo Streptococcus sanguinis, e as associações Streptococcus sanguinis e Candida albicans e Streptococcus sanguinis, Streptococcus mutans... / The aim of this study has been to analyze, in vitro the adherence of Streptococcus sanguinis, Candida albicans and associations of those microorganisms with Streptococcus mutans to the surfaces of dental implants treated with calcium phosphate jetting, anodization, double acid attack and to those of smooth surface, with or without previous saliva or blood plasma incubation. Ten implants from each surface were selected for every studied microorganism and association. In order to analyze the adherence, suspensions of microorganisms bearing 106 viable cells/ml in spectrophotometer were prepared. Additionally, every microorganism and association was divided in three groups: in the first, an implant was removed from its wrap and put right away into the sauce; the second, it was previously drenched into saliva for one hour; and the last one, into plasma, for one hour, as well. The implants were separately placed in culturing plaque wells of cells containing saccharose sauce (in vitro plaque) and the microorganism’s suspension. After 24 hours of incubation time at 37 °C and 5% of CO2, the implants were taken washed three times for a minute in saline sterile solution and put in a sonicator holding 10 ml of saline in order to disperse adherent cells. Then, seriated dilutions were done, and sowing in culture media specific for each of the. After a 48hincubation time at 37°C and 5% of CO2, a counting was carried, of the colony forming units (UFC/ml) and the data were submitted to the ANOVA, Tukey test, at a significance level of 5%. To illustrate the adherence of the microorganisms, some samples were exposed to electronic sweeping microscopy. The results did show great microorganism adherence to the surfaces studied, mainly when associated forming a biofilm. The anodized surface... (Complete abstract click electronic access below)
|
66 |
Atividade biológica do óleo essencial de Cymbopogon nardus e do fitoconstituinte citronelal sobre cepas de Candida envolvidas com infecções peri-implantaresTrindade, Leonardo Antunes 26 February 2014 (has links)
Made available in DSpace on 2015-05-14T12:56:04Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 1501652 bytes, checksum: 4c9d4fada2cc41f87661b7f25404ae20 (MD5)
Previous issue date: 2014-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The study aimed to evaluate the biological activity of the essential oil of Cymbopogon nardus and citronellal phytochemical on Candida strains, checking the possible inhibition of adhesion to dental implants and cover screws. Initially, a screening was performed by the disk diffusion technique in Sabouraud Dextrose Agar (SDA) for the essential oils of Cinnamomum camphora (White Camphor), Melissa officinalis (Lemon Balm), Ocimum basilicum (Basil) and Cymbopogon nardus (citronella), as well as phytochemicals alpha pinene, citral, citronellal and carvacrol. After screening, the essential oil of C. nardus and citronellal were selected because they displayed significant antifungal activity. Then, essential oil was analyzed by Gas chromatography mass spectrometry (GC-MS). Subsequently, were determined MIC and MFC of essential oil and citronellal against 12 strains of Candida and tests of inhibition of adhesion to dental implants and cover screws, using the MIC of substances evaluated, followed by analysis on a Scanning Electron Microscope (SEM). Assays were performed in triplicate and chlorhexidine and nystatin were used as positive control. The data were analyzed on the software GraphPad Prism 4. Analysis of variance (ANOVA) with Tukey s post-test was carried out, with a confidence interval of 95%. The GC-MS analysis of the essential oil identified the major substance as citronellal terpenoid. The essential oil, citronellal, chlorhexidine and nystatin able to inhibit 100% of the strains was 64 μg/mL, 512 μg/mL, 64 μg/mL, 32 μg/mL, respectively. The essential oil inhibited the adhesion of C. albicans in the dental implants and cover screws (p <0.001). Citronellal only inhibited the growth of the strain in dental implants (p <0.001) with no significant results in the cover screws (p> 0.05) compared to the growth control. We conclude that the essential oil of C. nardus and citronellal have antifungal activity and are able to inhibit the in vitro adherence of C. abicans. / O estudo teve como objetivo avaliar a atividade biológica do óleo essencial de Cymbopogon nardus e do fitoconstituinte citronelal sobre cepas de Candida, verificando a possível inibição da aderência aos implantes dentários e cover screws. Inicialmente, foi realizado uma triagem por meio da técnica de disco-difusão em Agar Sabouraud Dextrose (ASD), para os óleos essenciais de Cinnamomum camphora (Cânfora Branca), Melissa officinalis (Erva Cidreira), Ocimum basilicum (Manjericão) e Cymbopogon nardus (Citronela), bem como dos fitoconstituintes alfa pineno, citral, citronelal e carvacrol. Após a triagem, o óleo essencial de C. nardus e o citronelal foram selecionados por terem apresentado expressiva atividade antifúngica. Em seguida, o óleo essencial foi analisado por cromatografia gasosa acoplada ao espectro de massa (GC-MS). Posteriormente, foram determinadas a CIM e CFM do óleo essencial e citronelal frente a 12 cepas de Candida e realizados testes de inibição da aderência aos implantes dentários e cover screws, utilizando-se a CIM das substâncias avaliadas, seguida de análise em Microscópio Eletrônico de Varredura (MEV). Os ensaios foram realizados em triplicata e a nistatina e clorexidina foram utilizadas como controle positivo. Os dados foram analisados no software GraphPad Prism 4. Foi realizada uma análise de variância (ANOVA) com pós-teste de Tukey ao nível de confiança de 95%. A análise por GC-MS do óleo essencial permitiu a identificação do terpenoide citronelal como substância majoritária. A CIM do óleo essencial, citronelal, clorexidina e nistatina capaz de inibir 100% das cepas foi 64 μg/mL; 512 μg/mL; 64 μg/mL; 32 μg/mL, respectivamente. O óleo essencial inibiu a aderência de C. albicans nos implantes dentários e cover screws (p<0,001). O citronelal inibiu apenas o crescimento da cepa nos implantes dentários (p<0,001), não apresentando resultados significantes nos cover screws (p>0,05) em relação ao controle de crescimento. Conclui-se que o óleo essencial de C. nardus e citronelal possuem atividade antifúngica e são capazes de inibir a aderência in vitro de C. abicans.
|
67 |
Overdentures mandibulares retidas por mini-implantes: acompanhamento de 2 anos de um ensaio clínico randomizado / Mini-implant-retained mandibular overdentures: 2-year follow-up a randomized trialLuciana Costa Crizóstomo 25 July 2017 (has links)
O tratamento com mini-implantes tem sido utilizado para retenção de overdentures por possuir menor custo, menor desconforto pós-operatório e proporcionar adequada reabilitação da estética, função e fonação. Este ensaio clínico randomizado, com acompanhamento de 2 anos, foi realizado com o intuito de comparar a qualidade de vida associada à saúde bucal (QVSB), satisfação do paciente, bem como as taxas de sucesso de implantes e overdentures, retidas por implantes ou mini-implantes. Na fase inicial, a amostra foi composta de 120 indivíduos edêntulos que foram alocados aleatoriamente em três grupos de acordo com o tratamento recebido: (GI) quatro mini-implantes, (GII) dois mini-implantes, ou (GIII) dois implantes regulares. Durante o acompanhamento de 1 e 2 anos, a amostra foi reduzida para 106 e 96 participantes, respectivamente. A QVSB, mensurada pelo questionário OHIP-EDENT, e a satisfação (aferida por questões específicas respondidas em EVA 100mm) foram avaliadas antes da intervenção e após o período de acompanhamento. Outra variável utilizada para verificar a efetividade do tratamento foi a taxa de sucesso de implantes e overdentures, que foi obtida por meio de parâmetros clínicos e sobrevivência dos implantes. Os grupos foram comparados por meio de Equações de Estimação Generalizadas (EEG) (α=0,05), e teste post hoc de Bonferroni. Após análise da diferença entre as médias dos escores obtidos para QVSB e satisfação, verificou-se diferença significante, entre grupos tratados e tempo, apenas para a segunda variável. Assim, a modalidade de tratamento não interferiu na qualidade de vida dos participantes após 1 e 2 anos. Para este período, a satisfação foi maior para o grupo I (GI: 1ano - Δ61 mm, 2 anos - Δ55 mm), embora o grupo II (GII: 1 ano - Δ52 mm, 2 anos - Δ 45 mm) apresentasse valores intermediários e o grupo 3 (GIII: 1 ano 32 mm, 2 anos - 31 mm), valores aceitáveis dentro do tratamento. A taxa de sobrevivência dos implantes foi maior para o grupo de implantes regulares: GI (n=152): 88,8%; GII (n=84): 82,1% e GIII (n=80): 97,5%. Para os critérios de sucesso, os únicos parâmetros a apresentarem diferenças entre os grupos foram dor (maior frequência, GIII) e sangramento à sondagem (maior frequência, GI), apenas no 2º ano. Índice de placa, sangramento e profundidade de sondagem aumentaram com o tempo, sendo que GI e GII atingiram menor média. Conclui-se que o tratamento com overdenture, independente do tipo de implantes, teve impacto positivo na QVSB, enquanto a satisfação foi maior no grupo de quatro mini-implantes. Além disso, overdentures retidas por mini-implantes ou implantes regulares atingiram sucesso clínico em 2 anos. / Mandibular overdentures retained by mini implants have provide a good retention and lower cost, postoperative discomfort in rehabilitation of aesthetics, function and phonation. This study aimed to follow up a 2-year randomized clinical trial to compare the quality of life associated with oral health (QVSB), patient satisfaction, as well as the success rates of implants and overdentures after the installation Of mini-implants (two or four) or two conventional implants. In the initial phase, the sample consisted of 120 edentulous individuals were randomly allocated into three groups according to the treatment received: (GI) four mini-implants, (GII) two mini-implants, or (GIII) two regular implants. During follow-up of 1 and 2 years the sample was reduced to 106 and 96 participants, respectively. The QVSB, measured by the OHIP-EDENT questionnaire, and satisfaction (measured by specific questions answered in EVA 100mm) were evaluated before the intervention and after the follow-up period. Another variable used to verify the effectiveness of the treatment was the success rate of implants and overdentures, which was obtained through clinical parameters and implant survival. The groups were compared using Generalized Estimation Equations (EEG) (α= 0.05), and post hoc Bonferroni test. After analyzing the difference between the means of the scores obtained for QVSB and satisfaction, a significant difference was observed between treated groups and time, only for the second variable. Thus, the treatment modality did not interfere in the participants\' quality of life after 1 and 2 years. For this period, the satisfaction was highest for the groups of four mini-implants (GI: 1 year - Δ61 mm, 2 years - Δ 55 mm), although the two mini-implants (GII: 1 year - Δ52 mm, 2 years - Δ 45 mm) presented intermediate values and the groups of regular implants (GIII: 1 year - 32 mm, 2 years - 31 mm) had acceptable values within the treatment. The survival rate of the implants was higher for the group of conventional implants: GI (n = 152): 88.8%; GII (n = 84): 82.1% and GIII (n = 80): 97.5%. For the success criteria, the only parameters to present differences between the groups in the second year were pain and bleeding. The first occurred more frequently in the GIII while the second occurred in the GI. Peri-implant parameters (IP, SS, PS) increased with time and groups of mini-implants reached lower mean. It was concluded that overdenture treatment, regardless of the type of implant, has a positive impact on QVSB, while satisfaction was higher in the group of four mini-implants. In addition, overdentures retained by mini-implants or regular implants have achieved clinical success in 2 years.
|
68 |
Avaliação de dispositivo para viabilização de análise de frequência de ressonância em implantes dentários em ovelhas / Cristiane Marques Dorce 13 April 2018 (has links)
Afirmação do problema. Estudos experimentais em animais são utilizados para avaliar previamente o resultado de pesquisas e sua necessidade de serem realizadas em humanos. Estudos em animais são fundamentais na implantodontia para que haja uma melhor compreensão da osseointegração. Durante o processo de execução de pesquisas nesse tipo de estudo, algumas dificuldades relacionadas ao manuseio, custos de manutenção e bem-estar dos animais tendem a dificultar o seu desenvolvimento. Finalidade. Esse estudo tem como objetivo, testar um novo dispositivo acoplado sobre o implante, para que possa atuar como uma extensão do mesmo, facilitando a realização da Análise de Frequência de Ressonância durante o processo de osseointegração permitindo que implantes instalados em ovelhas em diferentes períodos, possam ser reabertos sem que haja a necessidade de etapas cirúrgicas para a reabertura durante a realização de testes. Material e métodos. Foram utilizadas 4 ovelhas, sendo uma do Grupo Controle (GC) e 3 do Grupo Teste (GT). Cada animal recebeu oito implantes localizados próximos ao ângulo da mandíbula, sendo quatro do lado esquerdo e quatro do lado direito, totalizando, 32 implantes cone-morse Acqua® de 3,5 de diâmetro por 8,5mm de comprimento da empresa Neodent® que foram avaliados pela análise de frequência de ressonância com a medição do ISQ (Quociente de Estabilidade do Implante) utilizando um transdutor (SmartPeg) expressos numa escala de 0 a 100. Para o Grupo Controle (GC) as medições de ISQ foram realizadas pelo método convencional, onde o SmartPeg foi acoplado diretamente sobre a plataforma do implante. Já no Grupo Teste (GT) o dispositivo estudado, foi acoplado ao implante para que pudesse ser realizada a medição. Os períodos estudados foram: imediatamente após a cirurgia e com quatro semanas de osseointegração. Para a análise estatística foram empregados os testes de Wilcoxon e Man-Whitney com a probabilidade de 5% (p<0.05). Resultados. As médias obtidas no GC foram 50,47 imediatamente após cirurgia e 65,68 após 4 semana, enquanto que no GT foram 34,74 e 34,81, respectivamente. Comparando a diferença entre os grupos nas médias de ISQ imediatas e após quatro semanas, houve diferença significativa com p= 0.0321 e p= 0.0027, respectivamente, demonstrando que os resultados no GT nos dois períodos não foram equivalentes quando comparados ao GC. Conclusão. Os resultados demonstraram que o grupo teste, apesar de trazer benefícios em relação ao manuseio dos animais, não apresentou benefícios com relação à eficiência na leitura do ISQ, quando comparado ao método convencional. / Statement of the problem. Experimental studies in animals are used to pre-evaluate the results of research and their need to be performed in humans. Animal studies are fundamental in implantology so that there is a better understanding of osseointegration. During the execution of research in this type of study, some difficulties related to handling, maintenance costs and animal welfare tend to hinder its development. Purpose. This study aims to test a new device coupled on the implant, so that it can act as an extension of the same, facilitating the performance of the Resonance Frequency Analysis during the osseointegration process allowing implants installed in different periods of time, can be reopened without the need for surgical steps for reopening during testing. Material and methods. Four sheep were used, one being from the Control Group (GC) and 3 from the Test Group (GT). Each animal received eight implants located near the angle of the mandible, four on the left side and four on the right side, totaling 32 Acqua® 3.5 mm diameter 8.5 mm long implants of the company Neodent® that were evaluated by the resonance frequency analysis with the ISQ (Implant Stability Ratio) measurement using a transducer (SmartPeg) expressed on a scale of 0 to 100. For the Control Group (GC) the ISQ measurements were performed by the conventional method, where the SmartPeg was attached directly onto the implant platform. In the Test Group (GT) the studied device was attached to the implant so that the measurement could be performed. The periods studied were: immediately after surgery and four weeks of osseointegration. For the statistical analysis Wilcoxon and Man-Whitney tests were used, with a probability of 5% (p <0.05). Results. The averages obtained in the CG were 50.47 immediately after surgery and 65.68 after 4 weeks, while in the GT were 34.74 and 34.81, respectively. Comparing the difference between the groups in the means of immediate SAI and after four weeks, there was a significant difference with p = 0.0321 and p = 0.0027, respectively, demonstrating that the results in the WG in the two periods were not equivalent when compared to the CG. Conclusion. The results showed that the test group, despite having benefits in relation to the handling of the animals, did not present benefits in relation to the efficiency of the ISQ reading when compared to the conventional method.
|
69 |
Avaliação clínica e radiográfica do implante imediato e provisionalização na zona estética: estudo retrospectivoNeves, Leonardo da Costa January 2013 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2015-04-15T02:26:46Z
No. of bitstreams: 1
LEONARDO DA COSTA NEVES.pdf: 1692397 bytes, checksum: cf234ab38c6b5ede04f9548b2617473b (MD5) / Made available in DSpace on 2015-04-15T02:26:46Z (GMT). No. of bitstreams: 1
LEONARDO DA COSTA NEVES.pdf: 1692397 bytes, checksum: cf234ab38c6b5ede04f9548b2617473b (MD5)
Previous issue date: 2013 / O sucesso da terapia com implantes dentários vem das excelentes taxas de sobrevivência e dos benefícios psicológicos, estéticos e funcionais dos pacientes. Nas duas últimas décadas, o protocolo clínico para instalação de implantes imediatos em alvéolos frescos vem evoluindo, passando de um protocolo de duas fases, onde se faziam cirurgias com retalho total e muitas vezes sem retalho, com instalação de implante e posterior provisionalização, até atingir o estado atual, no qual se instala a prótese provisória imediatamente após a instalação do implante (IIPP). Este protocolo terapêutico vem sendo utilizando e aperfeiçoado ao longo do tempo, trazendo benefícios, como a preservação tecidual, diminuição do tempo de tratamento e maior aceitação do paciente. Apesar de a técnica ser bastante difundida, pouco se conhece sobre os principais determinantes ou fatores que possam afetar o comportamento dos tecidos peri-implantares em longo prazo. Sabe-se que uma combinação complexa de fatores clínicos e biológicos podem influenciar na estabilidade e manutenção do arcabouço dos tecidos peri-implantares, tais como: protocolo cirúrgico e protético, o biotipo gengival, posição do implante, tipo de abutment e formato da prótese. Este trabalho explora através de uma revisão de literatura alguns fatores relacionados ao IIPP, que possam interferir ou influenciar o comportamento dos tecidos periimplantares ao longo do tempo.
|
70 |
Implantes osseointegráveis instalados sobre raízes reimplantadas tardiamenteCardoso, Leandro de Carvalho [UNESP] 05 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-12-05Bitstream added on 2014-06-13T21:02:13Z : No. of bitstreams: 1
cardoso_lc_dr_araca.pdf: 1917765 bytes, checksum: a068b0645b4f20057a8f729027757d38 (MD5) / O objetivo deste trabalho foi analisar o reparo ósseo peri-implantar de implantes instalados sobre raízes dentárias reimplantadas tardiamente, apresentando processo de anquilose e reabsorção por substituição. Foram utilizados os terceiros e quartos pré-molares inferiores de 4 cães machos (Beagle). Os dentes foram seccionados, e as raízes mesiais extraídas e mantidas durante 1 hora em temperatura ambiente. Após a remoção do ligamento periodontal necrótico e tratamento endodôntico, imergiram-se em fluoreto de sódio por 5 minutos e reimplantou a porção no alvéolo esplintando nas porções distais. Nestas foram realizadas pulpotomia e restauração. Decorridos 30 dias, as porções mesiais tiveram suas coroas seccionadas. Após 5 meses, cinco implantes foram instalados em osso reparado, grupo I, (Controle); nove foram instalados nos alvéolos frescos pós-exodônticos das porções distais (Grupo II – Imediato) e doze implantes foram instalados sobre as raízes mesiais em processo de reabsorção radicular externa (Grupo III – experimental). Decorridos 120 dias, os resultados foram analisados pelo contato osso implante da superfície do implante sem roscas e das três primeiras roscas. Foi avaliada, também, a área de tecido ósseo presente nos espaços internos das três primeiras roscas e da área espelho correspondente. O contato osso implante foi de 55% no grupo controle, 48% no imediato e 40% no grupo experimental. A área de tecido ósseo foi, respectivamente, 71%, 61% e 55%, e a área espelho de tecido ósseo foi de 62%, 60% e 58%. Conclui-se que o reparo ósseo perimplantar de implantes instalados sobre raízes apresentou um pequeno em relação aos outros dois grupos. / The purpose of this study was to analyze the peri-implant bone repair of dental implants placed on delayed reimplated roots, with process of ankylosis and reabsorption by substitution. The lower third and fourth pre-molar of four male dogs (Beagle) was used. The teeth were cut, and the mesial roots were extracted and kept out for 1 hour at ambient temperature. After removal of necrotic periodontal ligament and endodontic treatment, the root was immersed in sodium fluoride for 5 minutes. Then it was reimplanted in the correspondent alveolar bone and splinted in distal portion. A pulpotomy and a crown restoration were conducted on the distal portion. After 30 days, the mesial portions had their crowns cut (decoronation).Moreover, 5 months later, five implants were installed in bone repair, Group I (Control), and nine were installed in the fresh socket of the distal portions, which were extracted (Group II - Immediate). Finally, twelve implants were installed on the mesial roots, with process of external resorption (Group III - experimental). After 120 days, the results were analyzed by bone implant contact, from the surface of the implant without threads to the first three threads. It was also evaluated the area of the bone tissue located in the internal spaces of the first three threads and the corresponding mirror area. The bone implant contact was 55% in the control group, 48% in the immediate group and 40% in the experimental group. The area of bone tissue in the internal threads area was respectively 71%, 61% and 55%, and the mirror area of bone tissue had the following results: 62%, 60% and 58%. It was concluded that peri-implant bone repair of the implant put on the roots with an external resorption showed delay compared to the other two groups.
|
Page generated in 0.0619 seconds