Spelling suggestions: "subject:"implante dentário"" "subject:"implante mentário""
51 |
Avaliação da deformação gerada nos componentes intermediários de prótese fixa implanto-suportada com diferentes alturas, com a utilização de extensômetros lineares elétricos / Assessment of the deformation of the generated in different heights of abutments of mandibular implant-supported prosthesis, with the use of strain GaugesSuedam, Valdey 10 June 2005 (has links)
Em prótese total fixa implanto-suportada as diferentes alturas dos intermediários traduzem-se em diferentes braços de alavanca aos quais os implantes são submetidos levando a um efeito de deformação dos componentes que até o momento é desconhecido. O objetivo deste trabalho foi verificar a deformação gerada em diferentes alturas de componentes intermediários de prótese total fixa mandibular implanto-suportada. Para isto foi utilizado um modelo mestre de forma circular confeccionado em aço comum (Aço 1010/20) com cinco perfurações onde foram adaptadas as réplicas de fixação de 3,75mm de diâmetro, nas quais foram fixados os intermediários. O trabalho apresentou dois grupos de três corpos de prova cada, divididos de acordo com o tipo de liga das infra-estruturas(CoCr ou PdAg) e altura dos intermediários (4,0 mm, 5,5 mm e 7,0 mm), respectivamente. Foi aplicada uma força de 100N, em um ponto de referência pré-determinado na extremidade livre, a uma distância de 15mm do centro da réplica de fixação terminal e realizadas leituras das deformações geradas na mesial e na distal de cada intermediário, com o uso de extensômetros lineares elétricos. Os resultados do estudo demonstraram que o aumento da deformação captada no intermediário adjacente ao cantilever é promovido pelo aumento da altura dos intermediários e também pela utilização de uma liga de alto módulo de elasticidade. / In implant-supported prosthesis the different heights of abutments represent different lever arms to which the implants are submitted, leading to a deformation of the components that is not completely understood. The objective of this study was to assess the deformation ocurring in different heights of abutments of mandibular implant-supported fixed prosthesis. A circular master cast made of steel (Steel 1010/20) was used with five perforations containing implant replicas of 3,75mm of diameter in which the abutments were seated. The specimens were divided in two groups of three specimens each, according to the type of alloy of the framework (CoCr or PdAg) and the abutment's height (4,0 mm, 5,5 mm and 7,0 mm), respectively. A force of 100N was applied at a point 15mm distal to the center of the terminal abutment. Readings of the deformations generated on the mesial and distal aspects of the abutment were obtained with the use of strain gauges. The results of this study demonstrated that the deformation observed in the abutments adjacent to the cantilever arm is proportional to the increase of the abutment's height and elastic modulous of the alloy.
|
52 |
Avaliação da distribuição das tensões ao redor de implantes em diferentes níves de inserção / Stress distribution around dental implants placed at different depths: a photoelastic evaluationZanardi, Piero Rocha 16 February 2017 (has links)
A perda óssea progressiva ao redor da plataforma dos implantes dentários é um desafio a ser vencido na clínica, uma vez que, interfere na manutenção e controle dos tecidos peri-implantares e pode afetar a estética. Esta pesquisa teve como objetivo avaliar a concentração de tensões ao redor de diferentes implantes dentários, variando a macrogeometria, conexão protética e profundidade da inserção da plataforma protética, sob carregamento axial ou oblíquo. Foram criados três modelos de resina fotoelástica para cada tipo de implante avaliado (hexágono externo, hexágono externo wedge, hexágono interno e cone Morse). Cada corpo de prova se diferenciou pelo posicionamento da plataforma do implante em relação à margem superior do bloco, em três posições diferentes: I - plataforma posicionada 2mm abaixo da margem do bloco; II - plataforma posicionada no mesmo nível da margem do bloco; III - plataforma posicionada 2mm acima da margem do bloco. Foi aplicada uma força de 100N através de um dispositivo instalado sobre pilares retos e angulados, simulando um carregamento axial e oblíquo respectivamente. Um total de 4 pontos foram avaliados de um lado do implante. Dados quantitativos foram coletados e utilizados para análise estatística. A regressão linear múltipla mostrou relação entre a distribuição das tensões com relação à profundidade de inserção independentemente do tipo de conexão protética ou do carregamento oclusal. O grupo I (2mm abaixo da margem) foi o que apresentou os menores valores (p<0.05) de tensão quando comparado com os outros grupos (II e III). De acordo com as limitações deste estudo pode-se concluir que a macrogeometria, profundidade de inserção da plataforma e tipo de carregamento oclusal influenciam no comportamento da distribuição das tensões ao redor dos implantes. Em relação à conexão protética, os resultados mostraram padrões de franjas semelhantes independentemente do tipo de conexão / The progressive bone loss at the neck of dental implant is a clinical concern since it affects the maintenance of dental esthetics. The stress concentration, the connection type and the microgap appear to be factors that cause alterations at the marginal bone level. The aim of this research was to evaluate the stress concentration around different dental implants, varying the macrogeometry, prosthetic connection and depth of the insertion of the prosthetic platform, under axial or oblique loading. Three blocks of photoelastic resin for each type of implant connection (external hexagon, external hexagon flattened, internal hexagon and Morse taper) were built. Each block differed in the position of the implant platform in relative to the upper margin of the block: I (2mm below), II (at the same level) and III (2mm above). A force of 100N was applied to both a straight and tilted abutments. A multiple linear regression showed the relation between the stress distribution and the insertion depth. For all the implant types, both with straight and tilted abutments, Group I presented the lowest stress concentration around the fixture when compared to group II and III (p<0,05). According to the limitations of this study it could be concluded that the macrogeometry, depth of insertion of the platform and type of occlusal loading influence the behavior of the distribution of stresses around the implants. Regarding the prosthetic connection, the results showed similar patterns of fringes regardless of the type of connection
|
53 |
Análise microbiológica da vedação com selante industrial de microgaps nas diferentes conexões implantares: estudo in vitro / Microbiological analysis of the seal with industrial sealant on the microgaps in the different implant connections: in vitro studyTunes, Fábio Sanches Magalhães 29 June 2018 (has links)
A utilização de implantes osseointegráveis e componentes protéticos tornaram-se recursos muito viáveis à resolução de casos simples e complexos na odontologia reabilitadora. No entanto, a junção implante componente pode apresentar problemas, tais como a presença de um microgap entre essas partes constituintes. Assim, vários materiais tem sido testados na tentativa de obstruir esse espaço, com resultados controversos. O objetivo deste estudo foi avaliar in vitro o comportamento de um adesivo anaeróbico (Loctite® 510, Henkel Ltda) monocomponente, de alta resistência e inerte, na vedação do microgap impedindo a passagem bacteriana do meio externo para o interno do conjunto. Foram utilizados 90 implantes de conexão externa hexagonal (n = 30), conexão interna hexagonal (n = 30) e conexão interna cônica (n = 30), divididos em Grupo Controle (n = 45) e Grupo Teste (n = 45). Os implantes foram abertos em fluxo laminar e cada unidade recebeu 3l de BHI estéril internamente. Sobre cada unidade era parafusado um componente protético especifico para cada marca e com torques recomendados pelos fabricantes com torquímetro digital. Os conjuntos Teste receberam ainda uma fina camada de adesivo que era aplicada com microbrush entre as partes; e todas as unidades dos grupos Controle e Teste foram vedados com material obturador provisório na sua porção mais coronal. Cada conjunto foi então imerso em 75 l de Enterococcus faecalis (ATCC 29212) em minitubos até o limite entre a junção implante/componente protético. Todas as amostras foram incubadas em estufa bacteriológica por 7, 14 e 28 dias a 37oC antes de serem reabertas. Após o período proposto, o conteúdo interno dos implantes foi coletado com cones de papel estéreis, diluído e semeado em placas de Petri, incubadas por 48 horas. Houve diferença significante entre o grupo teste e controle no grupo de conexão externa hexagonal, em todos os tempos (Teste de Fischer e Qui-quadrado, p 0.05). O adesivo anaeróbico testado funciona como barreira, não permitindo a migração de bactérias para o meio interno do conjunto implante/componente protético. / The use of dental implants and prosthetic components have become very feasible resources to solve simple and complex cases in rehabilitation dentistry. However, the implant component junction may present problems, such as the presence of a microgap between these components parts.Therefore, several materials have been tested in an attempt to obstruct this space, with controversial results. The objective of this study was to evaluate in vitro the behavior of an anaerobic monocomponent adhesive (Loctite® 510, Henkel Ltda), high resistance and inert characteristics, in the microgap seal preventing bacterial passage from the external side to the inner side of the assembly. A total of 90 implants were used, with hexagonal external connection (n = 30), internal hexagonal connection (n = 30) and internal conical connection (n = 30) divided into Control Group (n = 45). Implants were opened in laminar flow cabinet and each unit received 3l of sterile BHI internally. On each unit a specific prosthetic component was screwed in for each brand and with torques recommended by the manufacturers with digital torque wrench. The sets of Test also received a thin layer of adhesive that was applied with microbrush between the parts; and all units of the Control and Test groups were sealed with provisional obturator material in their most coronal portion. Each set was immersed in 75 l of Enterococcus faecalis (ATCC - 29212) in mini-tubes to the limit between the implant / prosthetic component junction. All samples were incubated in a bacteriological incubator for 7, 14 and 28 days at 37oC before being reopened. After the proposed period, the internal contents of the implants were collected with sterile paper cones, diluted and seeded in Petri dishes, incubated for 48 hours. There was a significant difference between the test and control groups in the hexagonal external connection group at all times (Fischer and Chi-square test, p 0.05). The anaerobic adhesive tested works as a barrier, not allowing the migration of bacteria into the internal environment of the implant / prosthetic component assembly.
|
54 |
Efeito de terapia fotodinâmica utilizando curcumina como fotossensibilizante sobre o biofilme de S. gordonii formado sobre superfícies lisa e rugosa de titânio / Effect of photodynamic therapy using curcumin as a photosensitizer on the S. gordonii biofilm formed on smooth and rough surfaces of titaniumRancan, Flavia Luiza 13 March 2017 (has links)
A prevenção das doenças periimplantares baseia-se em procedimentos de rotina na clínica, com a remoção mecânica do biofilme associada ou não de agentes antimicrobianos locais e sistêmicos. No entanto, o controle do biofilme oral sobre a superfície de implantes é dificultado particularmente sobre as superfícies rugosas do titânio, que apesar de facilitarem a osseointegração, também favorecem a formação do biofilme. Objetivos: Objetivou-se analisar in vitro o efeito da TFD (Terapia fotodinâmica) usando curcumina como fotossensibilizador sobre o biofilme formado na superfície de discos de titânio com superfície rugosa e lisa. Material e Métodos: Biofilme mono espécie de Streptococus gordonii, colonizador inicial do biofilme dental, foi formado em superfícies lisas (usinadas) e rugosas (tratadas) de discos de titânio por 72 horas. Os discos lisos e rugosos foram então distribuídos em 3 grupos: tratados por 5 minutos com curcumina (60?M), clorexidina 0,12% como controle positivo e solução de DMSO (dimetilsufóxido), etanol e água como controle negativo (veículo da curcumina). As amostras foram divididas em 2 sub-grupos: ativado por LED azul (455-492nm) por 7 minutos e não-ativado. A atividade metabólica do biofilme foi determinada pelo método de redução do Sal tetralisol XTT e os resultados analisados estatisticamente pela análise da variância (ANOVA) seguida pelo teste de Tukey (p < 0,05). Resultados: Na ausência de luz, apenas o tratamento com clorexidina promoveu redução microbiana (controle positivo). O tratamento com curcumina ativada pela luz azul reduziu o número de bactérias viáveis no biofilme em 71% nos discos lisos e em 77% nos rugosos, não havendo diferença estatística com o controlepositivo.Conclusão: Os dados in vitro indicam que TFD associada à curcumina tem atividade sobre biofilme microbiano, sugerindo seu potencial no controle do biofilme oral sobre a superfície de titânio, e que este efeito independe da topografia da superfície. / Prevention of periimplant diseases is based on routine procedures in the clinic, with the mechanical removal of biofilm associated or not with local and systemic antimicrobial agents. However, the control of oral biofilm on the surface of implants is particularly difficult on the rough surfaces of titanium, which, although facilitating osseointegration, also favors biofilm formation. Objectives: The objective of this study was to analyze in vitro the effect of PDT using curcumin as a photosensitizer on the biofilm formed on the surface of titanium discs with a rough and smooth surface. Material and Methods: Biofilm mono species of Streptococus gordonii, initial colonizer of the dental biofilm, was formed on smooth (machined) and rough (treated) surfaces of titanium discs for 72 hours. The smooth and rough discs were then divided into 3 groups: treated for 5 minutes with curcumin (60 ?M), 0.1% chlorhexidine as a positive control and DMSO, ethanol and water solution as a negative control. The samples were divided into 2 subgroups: activated by blue LED (455-492nm) for 7 minutes and non-activated. The metabolic activity of the biofilm was determined by the reduction XTT salt method and the results analyzed statistically by ANOVA followed by the Tukey\'s test (p <0.05) Results: In the absence of light, only the chlorhexidine treatment promoted microbial reduction (positive control). The blue light-activated curcumin treatment reduced the number of viable bacteria in the biofilm in 71% in the smooth discs and in 77% in the wrinkles, and there was no statistical difference with the positive control. Conclusion: In vitro data indicate that PDT associated with curcumin has activity on microbial biofilm, suggesting its potential in the control of oral biofilm on the titanium surface, and that this effect is independent of surface topography.
|
55 |
Efeito do material de recobrimento na deformação sofrida por infra-estruturas de próteses fixas implanto-suportadas, utilizando extensômetros lineares elétricosGrando, Antônio Francisco 31 March 2003 (has links)
O sucesso dos implantes osseointegrados tem a influência decisiva dos aspectos biomecânicos, os quais interagem implantes, tecido ósseo e as próteses. O equilíbrio das forças que atuam sobre este complexo, remete-nos às diversas técnicas e materiais utilizados para a confecção das próteses fixas implanto-suportadas. O desenvolvimento de técnicas e materiais, bem como os desenhos das próteses vem trazendo um novo alento nas pesquisas. Este trabalho teve como objetivo averiguar a influência dos materiais de recobrimento estético, utilizados na confecção de próteses fixas implanto-suportadas, com relação à deformação destas próteses. Esta análise foi feita utilizando-se extensômetros lineares elétricos, analisando dois materiais de recobrimento. Um corpo de prova simulando uma prótese fixa de arco total, fundida em liga de paládioprata e recoberta em uma de suas metades por porcelana e na outra, por resina acrílica termopolimerizável. O corpo de prova foi fixado a um modelo-mestre e, após, aplicada uma carga estática vertical de 35,2 N, na extremidade livre, a uma distância de 10, 15 e 20 mm para distal do centro do implante terminal. Os resultados demonstraram que a aplicação de materiais de recobrimento estético, sobre uma infraestrutura metálica, tornam a mesma mais rígida e conseqüentemente com menor deformação. Outro fator confirmado nesta pesquisa foi a influência direta da extensão da extremidade livre que, nos pontos mais distantes de aplicação da carga, proporcionou maiores deformações. A pesquisa demonstrou que a porcelana proporciona menores índices de deformação da infra-estrutura metálica a ela associada, porém, fatores clínicos como qualidade e quantidade óssea, número e disposição dos implantes é que definem a escolha do material de recobrimento mais apropriado para cada situação. / The success of osseointegrated implants has a decisive influence of biomechanical aspects in wich implants, bone tissue and prosthesis are involved. The balance between the forces acting on this complex refer us to the diversity of methods and materials used to fabricate implant supported prosthesis. The aim of this study was to verify the influence of aesthetic covering materials on the deformation of cantilevered frameworks. Strain gauges were bonded to the inferior surface of a silver-palladium framework covered with ceramic and thermoacrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2N vertical static load was apllied to the free end at the distances of 10, 15 and 20mm distal to the terminal abutment. The results showed that the use of a rigid material such as ceramic stiffen even more the framework, with consequently less deformation. Another finding that was confirmed in this study was the direct influence of cantilever length on deformation of implant supported frameworks.
|
56 |
Efeitos do tratamento químico na descontaminação de superfícies de implantes metálicos: estudo microscópico em subcutâneos de ratos / Effects of chemical treatment of surfaces in decontamination of metallic implants: microscopic study in subcutaneous ratsLara, Rafael Mansano de Castro 09 March 2012 (has links)
O objetivo deste trabalho foi avaliar o efeito do tratamento químico com ácido cítrico, tetraciclina, EDTA e ácido fosfórico em discos de titânio de superfícies lisas e rugosas, após serem contaminados por biofilme bacteriano humano, e inseridos no tecido conjuntivo subcutâneo de ratos. Utilizou-se 180 discos de titânio, sendo 90 lisos e 90 rugosos, que foram colocados em 19 placas de acrílico utilizadas por voluntários durante 7 dias. Estes discos foram divididos em 12 grupos contendo 15 discos cada um: Grupo 1L: 15 discos lisos tratados com ácido cítrico; Grupo 1R: 15 discos rugosos tratados com ácido cítrico; Grupo 2L: 15 discos lisos tratados com tetraciclina ácida; Grupo 2R: 15 discos rugosos tratados com tetraciclina ácida; Grupo 3L: 15 discos lisos tratados com EDTA; Grupo 3R: 15 discos rugosos tratados com EDTA; Grupo 4L: 15 discos lisos tratados com ácido fosfórico; Grupo 4R: 15 discos rugosos tratados com ácido fosfórico; Grupo CL: 15 discos lisos que não receberam descontaminação (controle positivo liso); Grupo CR: 15 discos rugosos que não receberam descontaminação (controle positivo rugoso); Grupo EL: 15 discos lisos que não foram contaminados (controle negativo liso) e Grupo ER: 15 discos rugosos que não foram contaminados (controle negativo rugoso). Estes discos foram implantados no subcutâneo de ratos, os quais foram sacrificados após 7, 28 ou 84 dias. Foi realizada a avaliação microscópica descritiva e quantitativa do tecido conjuntivo formado nestes ratos. Foram avaliadas as médias das espessuras das cápsulas, a densidade de fibroblastos e de neutrófilos nos 3 períodos de tempo. Os resultados mostraram diferença na densidade de neutrófilos principalmente aos 7 dias e o ácido fosfórico mostrou os melhores resultados neste período, e ao final de 84 dias todos os tratamentos apresentaram resultados similares inclusive com relação ao grupo controle contaminado. Com relação à rugosidade os discos de superfícies lisas, apresentaram menor média na espessura da cápsula comparandose com os discos de superfícies rugosas, talvez demonstrando um aspecto de maior biocompatibilidade da superfície lisa após receber o tratamento de descontaminação, o que sugeriria maior efetividade na descontaminação dos protótipos lisos. / The purpose of this investigation was to evaluate the effects of treatment with citric acid, tetracycline, EDTA and phosphoric acid in titanium disks in smooth and roughened surfaces contaminated by bacterial biofilms in the connective tissue of rats. One hundred eighty titanium disks were used; 90 smooth surfaces and 90 roughened titanium surfaces, which were placed in 19 acrylic plates that were used by volunteers for 7 days. These disks were divided into 12 groups containing 15 disks each; Group 1L: 15 smooth disks were treated with citric acid; Group 1R: 15 roughened disks were treated with citric acid; Group 2L: 15 smooth disks were treated with tetracycline acid; Group 2R: 15 roughened disks were treated with tetracycline rough acid; Group 3L: 15 smooth disks were treated with EDTA; Group 3R: 15 roughened disks were treated with EDTA; Group 4L: 15 smooth disks were treated with phosphoric acid; Group 4R: 15 roughened disks were treated with phosphoric acid; Group CL: 15 smooth disks received no econtamination (smooth positive control); CR: 15 roughened disks did not receive decontamination (roughened positive control); EL: 15 smooth disks were not infected (smooth negative control) and ER: 15 roughened disks were not infected (roughened negative control). These disks were implanted subcutaneously in rats that were sacrificed after 7, 28 or 84 days. A descriptive and quantitative microscopic evaluation was performed. The average thickness of the capsules and the density of fibroblasts and neutrophils in three time periods were evaluated. The results showed differences in the density of neutrophilis mainly at 7 days and phosphoric acid showed the best results in this period, and at the end of 84 days, all treatments showed similar results even with the control group infected. In relation to the roughness, the smooth disks had a lower average capsule thickness compared with roughened disks, perhaps demonstrating an aspect of greater biocompatibility smooth surface, which would suggest greater effectiveness in decontamination of smooth disks.
|
57 |
Overdentures mandibulares retidas por mini-implantes: acompanhamento de 2 anos de um ensaio clínico randomizado / Mini-implant-retained mandibular overdentures: 2-year follow-up a randomized trialCrizóstomo, Luciana Costa 25 July 2017 (has links)
O tratamento com mini-implantes tem sido utilizado para retenção de overdentures por possuir menor custo, menor desconforto pós-operatório e proporcionar adequada reabilitação da estética, função e fonação. Este ensaio clínico randomizado, com acompanhamento de 2 anos, foi realizado com o intuito de comparar a qualidade de vida associada à saúde bucal (QVSB), satisfação do paciente, bem como as taxas de sucesso de implantes e overdentures, retidas por implantes ou mini-implantes. Na fase inicial, a amostra foi composta de 120 indivíduos edêntulos que foram alocados aleatoriamente em três grupos de acordo com o tratamento recebido: (GI) quatro mini-implantes, (GII) dois mini-implantes, ou (GIII) dois implantes regulares. Durante o acompanhamento de 1 e 2 anos, a amostra foi reduzida para 106 e 96 participantes, respectivamente. A QVSB, mensurada pelo questionário OHIP-EDENT, e a satisfação (aferida por questões específicas respondidas em EVA 100mm) foram avaliadas antes da intervenção e após o período de acompanhamento. Outra variável utilizada para verificar a efetividade do tratamento foi a taxa de sucesso de implantes e overdentures, que foi obtida por meio de parâmetros clínicos e sobrevivência dos implantes. Os grupos foram comparados por meio de Equações de Estimação Generalizadas (EEG) (α=0,05), e teste post hoc de Bonferroni. Após análise da diferença entre as médias dos escores obtidos para QVSB e satisfação, verificou-se diferença significante, entre grupos tratados e tempo, apenas para a segunda variável. Assim, a modalidade de tratamento não interferiu na qualidade de vida dos participantes após 1 e 2 anos. Para este período, a satisfação foi maior para o grupo I (GI: 1ano - Δ61 mm, 2 anos - Δ55 mm), embora o grupo II (GII: 1 ano - Δ52 mm, 2 anos - Δ 45 mm) apresentasse valores intermediários e o grupo 3 (GIII: 1 ano 32 mm, 2 anos - 31 mm), valores aceitáveis dentro do tratamento. A taxa de sobrevivência dos implantes foi maior para o grupo de implantes regulares: GI (n=152): 88,8%; GII (n=84): 82,1% e GIII (n=80): 97,5%. Para os critérios de sucesso, os únicos parâmetros a apresentarem diferenças entre os grupos foram dor (maior frequência, GIII) e sangramento à sondagem (maior frequência, GI), apenas no 2º ano. Índice de placa, sangramento e profundidade de sondagem aumentaram com o tempo, sendo que GI e GII atingiram menor média. Conclui-se que o tratamento com overdenture, independente do tipo de implantes, teve impacto positivo na QVSB, enquanto a satisfação foi maior no grupo de quatro mini-implantes. Além disso, overdentures retidas por mini-implantes ou implantes regulares atingiram sucesso clínico em 2 anos. / Mandibular overdentures retained by mini implants have provide a good retention and lower cost, postoperative discomfort in rehabilitation of aesthetics, function and phonation. This study aimed to follow up a 2-year randomized clinical trial to compare the quality of life associated with oral health (QVSB), patient satisfaction, as well as the success rates of implants and overdentures after the installation Of mini-implants (two or four) or two conventional implants. In the initial phase, the sample consisted of 120 edentulous individuals were randomly allocated into three groups according to the treatment received: (GI) four mini-implants, (GII) two mini-implants, or (GIII) two regular implants. During follow-up of 1 and 2 years the sample was reduced to 106 and 96 participants, respectively. The QVSB, measured by the OHIP-EDENT questionnaire, and satisfaction (measured by specific questions answered in EVA 100mm) were evaluated before the intervention and after the follow-up period. Another variable used to verify the effectiveness of the treatment was the success rate of implants and overdentures, which was obtained through clinical parameters and implant survival. The groups were compared using Generalized Estimation Equations (EEG) (α= 0.05), and post hoc Bonferroni test. After analyzing the difference between the means of the scores obtained for QVSB and satisfaction, a significant difference was observed between treated groups and time, only for the second variable. Thus, the treatment modality did not interfere in the participants\' quality of life after 1 and 2 years. For this period, the satisfaction was highest for the groups of four mini-implants (GI: 1 year - Δ61 mm, 2 years - Δ 55 mm), although the two mini-implants (GII: 1 year - Δ52 mm, 2 years - Δ 45 mm) presented intermediate values and the groups of regular implants (GIII: 1 year - 32 mm, 2 years - 31 mm) had acceptable values within the treatment. The survival rate of the implants was higher for the group of conventional implants: GI (n = 152): 88.8%; GII (n = 84): 82.1% and GIII (n = 80): 97.5%. For the success criteria, the only parameters to present differences between the groups in the second year were pain and bleeding. The first occurred more frequently in the GIII while the second occurred in the GI. Peri-implant parameters (IP, SS, PS) increased with time and groups of mini-implants reached lower mean. It was concluded that overdenture treatment, regardless of the type of implant, has a positive impact on QVSB, while satisfaction was higher in the group of four mini-implants. In addition, overdentures retained by mini-implants or regular implants have achieved clinical success in 2 years.
|
58 |
Análise da durabilidade, retenção e tensão em overdentures retidas por implantes associadas ou não a mini-implantes posteriores / Durability, retention and stress analysis of implants-retained overdentures associated or not to posterior mini-implantsAlves, Suleima do Vale 02 June 2017 (has links)
O objetivo desse estudo in vitro foi analisar a durabilidade, retenção e tensão gerada nos implantes de overdenture retidas por sistema bola/O\'ring ou barra/clipe, associados ou não a mini-implantes na região posterior da mandíbula. Foram utilizados implantes anteriores cone-Morse (3,75 x 11 mm) e mini-implantes de corpo único (2 x 10 mm) e os grupos divididos em (n=12): G2O: overdenture sobre 2 implantes com bola/O´rings; G1B: overdenture sobre 2 implantes com barra/clipe; G4O: overdenture sobre 2 implantes com bola/O´rings e 2 mini-implantes na região posterior; G1B2O: overdenture sobre 2 implantes com barra/clipe e 2 mini-implantes na região posterior. Para avaliação qualitativa das áreas de compressão e/ou tração nos modelos em poliuretano, foi realizado o método de correlação de imagens digitais, com carregamento oclusal (300 N) e pontual (250 N) com captura em vista frontal e lateral dos modelos experimentais. Foi realizado ensaio de fadiga acelerada progressiva com cargas de 80 N, 140 N, 200 N, 260 N, 320 N e 380 N, frequência de 5Hz, totalizando 120.000 ciclos. Para avaliação da retenção os modelos foram submetidos a ensaio de tração previamente a termociclagem (Tempo 1), após 200 N (Tempo 2) e após 380 N (Tempo 3) e a força de retenção foi registradas em triplicata e a média obtida em cada tempo. A análise da durabilidade dos componentes retentivos foi realizada após os ensaios de tração nos tempos determinados por microscopia óptica. As imagens da aplicação de carga oclusal, mostraram que as tensões nos grupos 1B e 1B2O foram semelhantes, nos grupos 2O e 4O apresentaram tensões de tração na região anterior, porém no grupo 4O houve melhor distribuição por toda área analisada. Na aplicação de carga pontual, todos os modelos apresentaram tensões de compressão na região posterior e de tração na anterior, porém com maior intensidade nos modelos 2O e 4O, e menor intensidade nos modelos 1B e 1B2O. Nas análises sobre a retenção dos componentes, não houve diferença significativa (p < 0,05) entre os grupos 1B-1B2O, porém houve diferença significativa entre os grupos 2O-4O, notando maior força retentiva no grupo 4O. As comparações entre os grupos, 1B-2O e 1B2O-4O houve diferença significativa, sendo que os grupos com sistema barra/clipe obtiveram maior retenção que os grupos com O´rings. Nas imagens microscópicas não houve diferença significativa na estrutura interna dos O´rings, porém houve diferença significativa nos clipes. Conclui-se que a durabilidade, retenção e distribuição de tensão não se altera com a colocação de mini-implantes posteriores em overdentures com sistema retentivo barra/clipe. Com sistema retentivo bola/O\'ring a instalação de mini-implantes aumentou a força de retenção e favoreceu a distribuição das tensões, reduzindo a alavanca para posterior. / The purpose of this in vitro study was to analyze the durability, retention and strength caused for implants-retained overdentures by ball/O-ring system or bar/clip, associated or not mini-implants in the posterior region of the mandible. Anterior Morse taper connection implants (3.75 x 11 mm) and single-body mini-implants (2 x 10 mm) were used and the groups divided to (n=12): G2O: implants-retained overdentures 2 implants with ball/O-rings ; G1B: implants-retained overdentures 2 bar/clip implants; G4O: implants-retained overdentures 2 implants with ball/O-rings and 2 mini-implants in the posterior region ; G1B2O: implants-retained overdentures 2 implants with bar/clip and 2 mini-implants in the posterior region. For the qualitative evaluation of compression and/or traction areas in polyurethane models, a digital image correlation method (DIC) with occlusal (300 N) and punctual (250 N) loading was applied with frontal and lateral views of the experimental models. An accelerated progressive fatigue test with loads of 80 N, 140 N, 200 N, 260 N, 320 N and 380 N, frequency of 5 Hz, completing120,000 cycles. In order to evaluate the retention force, the models were submitted to traction force, previously to thermocycling (Time 1) after 200 N (Time 2) and posteriorly 380 N (Time 3), being the retention force recorded in triplicate. The durability analysis, by optic microscopy, of the retentive components was performed after the traction tests at the determined times. The application images of the occlusal load, showed that the stress in groups 1B and 1B2O were similar, in groups 2O and 4O presented stress in the anterior region, but in the 4O group, there was better distribution throughout the analyzed area. In the application of punctual loading, all the models presented compression tensions in the posterior region and traction in the anterior one, but with greater intensity in the 2O and 4O models, and lower intensity in the 1B and 1B2O models. In the retention analyzes of the components, there was no significant difference (p <0.05) between groups 1B-1B2O, but there was a significant difference between groups 2O-4O, noting a higher retentive force in the 4O group. The comparisons between the groups, 1B-2O and 1B2O-4O showed a significant difference, and the groups with bar/clip systems obtained higher retention than the groups with O-rings. In the microscopic images, there was no significant difference in the O-rings internal structure, but there was a significant difference in the clips images. It was concluded that the durability, retention and stress distribution do not change with the placement of posterior mini-implants in overdentures with retentive bar/clip system. With retentive system ball/O-ring the installation of mini-implants increased the retention force and favored much the distribution of the stress, thus reducing the forefoot leverage to the posterior part of the prosthesis.
|
59 |
Citocompatibilidade de filmes nanoestruturados associados à prata aplicados sobre titânio: análise em cultura de osteoblastos / Biocompatibility of nanostructured films associated to silver applied on titanium: analysis in osteoblasts cultureChristiana Fontão Kassab 17 April 2015 (has links)
A contaminação dos implantes e seus componentes protéticos por patógenos específicos, ainda é um problema a ser resolvido na Implantodontia. Nanoestruturas associadas à prata, aplicadas em superfície de titânio, têm sido investigadas e vêm demonstrando inibir significativamente a adesão, crescimento e colonização de uma vasta gama de microrganismos patogênicos, inclusive os resistentes a antibióticos. O objetivo deste experimento foi verificar a presença de toxicidade de nanoestruturas associadas à prata, aplicadas à superfície de titânio, frente a cultura de osteoblastos, visando desenvolver um material biocompatível, promissor na corrida pela prevenção da colonização bacteriana dos implantes. Discos de titânio comercialmente puro foram revestidos com três tipos diferentes filmes nanoestruturados. As amostras foram expostas a culturas de linhagens imortalizadas de osteoblastos (MC3T3-E1) e submetidas a ensaios de toxicidade direta (MTT), após 24h, 48h e 72h de incubação, a fim de determinar a taxa de proliferação e redução da viabilidade celular. Além disso, para verificar adesão e morfologia celular, foi realizada Microscopia Eletrônica de Varredura (MEV) após 24h de incubação. No ensaio de toxicidade celular MTT, após 48h de incubação, as superfícies nanoestruturadas, nomeadas TiAg, TiAA e SiO2, comportaram-se de maneira muito similar ao grupo controle de titânio puro (Ti) (p<0,05). O grupo SiO2 registrou maior absorbância em 24h, com diferença relevante em relação a todos os outros grupos (testes e controles). Em MEV foram verificadas uma morfologia celular compatível com viabilidade e presença de adesão dos osteoblastos em todas as superfícies testadas, similar aos grupos controles. Dessa forma, verificou-se que os três filmes nanoestruturados demonstraram biocompatibilidade a osteoblastos. / Contamination of implants and their prosthetic components by specific pathogens is still a problem to be solved in Implantology. Nanostructures associated to silver applied on titanium surface have been investigating, and have showing to inhibit significantly the adhesion, and growth of a broad range of pathogenic microorganisms, including antibiotic-resistant ones. The aim of this experiment was to verify the presence of toxicity in nanostructures associated to silver applied to titanium surface against osteoblast culture, in order to develop a biocompatible promising material in the race for prevention on implants bacterial colonization. Each commercially pure titanium disk received one of three different nanostructured films: SiO2, TiAg, and TiAA. Samples have exposed to cultures of immortalized lines osteoblasts (MC3T3-E1), and submitted to direct toxicity assay (MTT) after 24h, 48h and 72h of incubation to determine the proliferation rate and cell viability reduction. Furthermore, to verify adhesion and cell morphology, Scanning Electron Microscopy (SEM) has performed after 24h incubation. The 48h MTT cell toxicity assay showed similarity in results among test surfaces and pure titanium control group (Ti) (p <0.05). The SiO2 group registered higher absorbance in 24h, with significant difference regarding to all other groups (tests and controls). SEM exhibited cell morphology indicative of viability, and presence of osteoblast adhesion on all test surfaces, similar to control groups. Thus, it found of that three nanostructured films demonstrated osteoblasts compatibility.
|
60 |
Avaliação da citotoxicidade dos extratos da corrosão de mini-implantes ortodônticos de TI- 6AL-4V após imersão em saliva artificial fluoretada por 30, 90 ou 180 diasLemes, Sandra Stival dos Santos 25 February 2008 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-02-12T19:32:51Z
No. of bitstreams: 2
Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-02-12T19:33:13Z (GMT) No. of bitstreams: 2
Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-02-12T19:33:13Z (GMT). No. of bitstreams: 2
Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2008-02-25 / The alloys used in the orthodontic therapy are subject to the corrosion process in the oral
environment. Orthodontic mini-implants Ti-6Al-4V are an excellent source for intraoral
anchorage; however, their corrosion resistance in the presence of fluoride is currently
unknown. The purpose of this in vitro study was to evaluate the cytotoxic effects of the
corrosion extracts of mini-implants Ti-6Al-4V from three different manufacturers when
exposed to 200 g/L of sodium fluoride containing artificial saliva for 30, 90 or 180 days. The
cytotoxic effects of their corrosion products on L929 cell culture was evaluated by MTT (3-
[4,5-dimethylthiazol-2-yl]2,5-diphenyltetrazolium bromide) assay, for cell metabolism and
proliferation. The extracts were not cytotoxic and the cytotoxicity assay demonstrated a
similar behavior for the samples immersed in artificial saliva in the three evaluated periods.
The qualitative analysis, through SEM did not show characteristics of corrosion. The results
indicated that the mini-implants tested presented a high corrosion resistance and
biocompatibility. / As ligas metálicas utilizadas na terapia ortodôntica estão sujeitas ao processo de corrosão na
cavidade bucal. Mini-implantes de Ti-6Al-4V utilizados em ortodontia tornou-se um ótimo
recurso de ancoragem intrabucal, contudo, sua resistência à corrosão na presença de flúor é
pouco conhecida. O objetivo deste trabalho in vitro foi avaliar a citotoxicidade dos extratos da
corrosão de mini-implantes ortodônticos de Ti-6Al-4V de três diferentes marcas comerciais,
quando expostos em saliva artificial fluoretada contendo 200 µg/L de fluoreto de sódio, por
30, 90 ou 180 dias. A citotoxicidade dos extratos foi avaliada, em cultura de células L929,
por meio da análise do ensaio do MTT (3-{4,5-dimetiltiazol-2il} -2,5-difenil brometo de
tetrazólio). Os extratos não foram citotóxicos e o ensaio de citotoxicidade revelou não haver
diferenças entre as amostras, demonstrando um comportamento semelhante para os extratos
provenientes dos mini-implantes imersos em saliva nos três períodos avaliados. A análise
qualitativa, por meio do MEV não revelou áreas com características de corrosão propriamente
dita. Os resultados demonstraram que os mini-implantes testados apresentam alta resistência à
corrosão e sugerem que são biocompatíveis.
|
Page generated in 0.0559 seconds