• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1383
  • 114
  • 47
  • 44
  • 44
  • 43
  • 26
  • 16
  • 13
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 1557
  • 886
  • 745
  • 656
  • 292
  • 235
  • 207
  • 162
  • 156
  • 140
  • 139
  • 138
  • 137
  • 136
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação do comportamento mecanico de proteses fixas implantossuportadas por meio da tecnica de extensometria eletrica / Evaluation of mechanic behavior of fixed prosthesis implantsupported by means of electric extensometry technic

Prado, Devanir Silva Vieira, 1951- 13 August 2018 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:38:34Z (GMT). No. of bitstreams: 1 Prado_DevanirSilvaVieira_M.pdf: 895028 bytes, checksum: fe09fdf9bad8a966f0302b161600791e (MD5) Previous issue date: 2009 / Resumo: Muitas vezes, as tensões são causadas por alterações nas adaptações das estruturas protéticas ao implante, além dos desajustes marginais entre as fixações e as reabilitações protéticas. Este trabalho tem como objetivo, avaliar a distribuição de compressão e tração dos pilares protéticos e infra-estrutura metálica fundida em liga de cobalto-cromo, pela técnica de monobloco, simulando uma prótese fixa implantossuportadas sobre 06 implantes com distância de 10 mm entre implantes e com extremo livre (cantilever) bilateral com extensão de 20 mm, colocados através da curvatura da linha oclusal mandibular. Em cada pilar foram colados quatro extensômetros e um em cada cantilever, após o apertamento de todos pilares e a infra-estrutura aos implantes, foi submetido a um ensaio mecânico com cargas compressivas verticais de 150 N, analisando quantitativamente os resultados bem precisos através da extensometria. Os resultados foram obtidos usando os maiores valores de carga axial registrados em cada ponto de força aplicado, registrando deformação para infra-estrutura, pilares e os cantilevers. Com aplicação de carga nos pontos entre os pilares, foi obtido nos pilares mais próximos a aplicação da carga um maior grau de compressão e nos pilares mais distantes, em menor grau de acordo com a distribuição de carga deformação por compressão e ou/ tração. Com aplicação de carga vertical máxima no cantilever, o pilar adjacente foi o mais solicitado por compressão, independente do ponto de aplicação da carga e o último pilar do lado oposto em menor intensidade, também solicitado por compressão, formando um eixo de rotação, no qual os componentes anteriores foram solicitados em regime de tração (alavanca). O carregamento mecânico registrou deformação para a infraestrutura, pilares e cantilever. / Abstract: Frequently, stresses are caused by changes in adaptations of prosthetic structures to the implant besides marginal disajustment between prosthetic fixing and rehabilitations. This study aims to evaluate the distribution of compression and traction of the prosthetic sustainers and the methalic framework melted in cromocobalt alloy, through the monoblock technic simulating a fixed prosthesis implantsupported on 06 implants at the distance of 10mm between each other and with bilateral cantilever extending to 20mm, placed along the mandibular oclusal line curvature, with the extensometry technic. In each abutment there have been placed four strain guages and one in each cantilever, in configuration "Wheatstone Bridge", after all components having been fixed to the framework, it was submitted to a mechanic essay with vertical pressing charges of 150Ncm, checking quantitatively the accurate result through extensometry. Results have been obtained by using the greatest values of axial charge registered in each place of applied force,. On nearest pillars to the charge, It has been obtained a greater degree of compression (fulcrum), what corresponds to the amount of oclusal force applied to the equalizing stress force. And, therefore, the most distant pillars will assimilate a negative deformation ( compression) or a positive deformation (traction, seesaw), proportional to the lever arm. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
62

Avaliação da regeneração ossea em defeitos peri-implantares de deiscencia tratados com uma abordagem combinada associando celulas derivadas da medula ossea e regeneração ossea guiada : estudo histomorfometrico em cães / Evaluation of bone regeneration in dehiscence type peri-implant defects treated with a combined approach using bone marrow-derived cells and guided bone regeneration : a histomorphometrical study in dogs

Ribeiro, Fernanda Vieira 12 September 2009 (has links)
Orientadores: Marcio Zaffalon Casati, Karina Gonzales Silverio Ruiz / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T23:45:21Z (GMT). No. of bitstreams: 1 Ribeiro_FernandaVieira_D.pdf: 8018060 bytes, checksum: 8fc3b530db926d929facce5cfd30fb4e (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi avaliar histometricamente o reparo ósseo em defeitos periimplantares do tipo deiscência, criados cirurgicamente em cães, tratados com a associação de células derivadas da medula óssea (CMs) e regeneração óssea guiada (ROG). A medula óssea foi obtida a partir da crista ilíaca de oito cães beagle adultos machos. Células derivadas da medula óssea (CMs) foram isoladas, cultivadas in vitro e fenotipicamente caracterizadas com relação as suas propriedades osteogênicas. Os mesmos animais foram submetidos à extração bilateral dos primeiros molares e terceiro e quarto pré-molares inferiores. Após três meses, três leitos para a colocação de implantes foram confeccionados em cada lado da mandíbula, deiscências ósseas vestibulares foram criadas e, então, implantes de titânio de superfície usinada foram colocados. As deiscências ósseas foram tratadas aleatoriamente, de acordo com um dos seguintes grupos: 1) ROG+CMs+C: membrana de PTFE-e com reforço de titânio associada às células derivadas da medula óssea semeadas no carreador, 2) ROG+C: membrana de PTFE-e com reforço de titânio associada ao uso do carreador sem células, 3) CMs+C: células derivadas da medula semeadas no carreador, 4) ROG: membrana de PTFE-e com reforço de titânio, 5) C: carreador sem células e 6) Controle: nenhum tratamento. Após três meses, os animais foram sacrificados e os implantes em conjunto com os tecidos adjacentes foram processados laboratorialmente para obtenção de secções não descalcificadas. Os parâmetros avaliados foram: Contato direto osso-implante (CO), Preenchimento ósseo dentro das roscas do implante (PR) e Área de tecido ósseo fora das roscas (AF). In vitro, a caracterização fenotípica demonstrou que células derivadas da medula óssea apresentaram potencial osteogênico identificado pela formação de nódulos minerais e expressão de marcadores ósseos (fosfatase alcalina, sialoproteína óssea e colágeno tipo I). As análises histométricas revelaram que todos os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) demonstraram resultados estatisticamente similares (p>0,05) com relação à área de novo osso formado fora das roscas do implante, apresentando, no entanto, maior quantidade de osso neoformado fora dos limites das roscas, quando comparados aos demais grupos (CMs+C, C e Controle) (p<0,05). Adicionalmente, foi observado que o preenchimento ósseo dentro das roscas foi estatisticamente semelhante entre os grupos que utilizaram membrana (ROG+CMs+C, ROG+C, ROG) e o grupo tratado com células sem barreira (CMs+C) (p>0,05), enquanto todos estes grupos mostraram um preenchimento ósseo significativamente superior ao grupo Controle (p<0,05). Com relação à porcentagem de contato osso-implante, embora os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) tenham apresentado valores estatisticamente maiores quando comparados aos defeitos dos grupos C e Controle (p<0,05), uma tendência para aumento da extensão de contato osso-implante foi observada nos defeitos tratados com células sem a associação da ROG (grupo CMs+C). Dentro dos limites do presente estudo, pôde-se concluir que embora as células derivadas da medula óssea, utilizadas isoladamente, tenham promovido bons resultados em relação à formação óssea dentro das roscas do implante, o seu uso, associado à ROG, não promoveu benefícios adicionais na formação óssea em defeitos peri-implantares de deiscência. / Abstract: The purpose of this investigation was to histometrically evaluate the bone healing in surgically created dehiscence-type defects around titanium implants treated with an association of bone marrow-derived cells (BMCs) and guided bone regeneration (GBR). Bone marrow cells were harvested from eight male adult beagle dogs, cultured in vitro and phenotypically characterized with regard to their osteogenic properties. Following, the same animals were subjected to bilaterally teeth extraction (lower premolars and the first molar) and three months later, three implant sites were drilled in each side of mandible, buccal bone dehiscences were created and titanium dental implants with machined surface were placed. Dehiscences were randomly assigned to one of the following groups: 1) GBR+BMCs+C: PTFE-e barrier placement associated with BMCs into the carrier, 2) GBR+C: PTFE-e barrier placement associated with carrier, 3) GBR: PTFE-e barrier placement, 4) BMCs+C: BMCs into the carrier, 5) C: carrier without cells e 6) Control: no treatment. After 3 months, the animals were sacrificed and the implants in conjunction with adjacent hard tissues were processed for undecalcified sections. Bone-to-implant contact (BIC), bone filling within the limits of implant threads (BF) and new bone area (BA) in a zone lateral to the implant surface were obtained. Results: In vitro, phenotypic characterization demonstrated that BMCs presented osteogenic potential identified by the mineral nodule formation and the expression of bone markers. Histometrically, inter-group analysis demonstrated that all defects treated with GBR (GBR+BMCs+C, GBR+C and GBR) were statistically similar in terms of BA (p>0.05), presenting significantly higher BA as compared with other groups (BMCs+C, C and Control) (p<0.05). With respect the BF, no differences were observed among GBR+BMCs+C, GBR+C, GBR and BMCs+C groups (p>0.05), whereas all these groups showed statistically superior BF as compared to Control group (p<0.05). Additionally, although the percentage of BIC has been significantly higher in the defects treated by barrier membrane (GBR+BMCs+C, GBR+C and GBR) as compared to C and Control groups (p<0.05), a trend towards to a greater extension of BIC has been observed for the defects treated with BMCs+C. Within the limits of this study, it was concluded that although the use of bone marrowderived cells has provided promising outcomes in terms of bone formation within the limits of implant threads, their use, in combination with GBR, has not promoted additional benefits on the bone regeneration in peri-implantar dehiscence type bone defects. / Doutorado / Periodontia / Doutor em Clínica Odontológica
63

Avaliação da perda de pre-carga e infiltração bacteriana em sistemas de implantes de encaixe conico e hexagono externo / Evaluation of reload loss and bacterial penetration on conical and external hexagon connection implant systems

Ricomini Filho, Antônio Pedro, 1983- 12 April 2009 (has links)
Orientador: Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T23:43:34Z (GMT). No. of bitstreams: 1 RicominiFilho_AntonioPedro_M.pdf: 1929547 bytes, checksum: 3218196794c582fbd092c07948036e16 (MD5) Previous issue date: 2009 / Resumo: A presença de microrganismos na interface implante e pilar é um dos fatores associado ao insucesso de implantes osseointegrados. Sistemas de implantes de encaixe cônico visam precisa adaptação entre o implante e o pilar, entretanto não se sabe o comportamento desses sistemas frente a condições de estresse da cavidade oral quanto à manutenção da pré-carga e capacidade de selamento bacteriano. Assim, o objetivo deste estudo foi avaliar a perda de précarga e a infiltração bacteriana na interface implante e pilar de sistemas de encaixe cônico e hexágono externo, submetidos à ciclagem térmica e fadiga mecânica (CF). Foram utilizados 48 implantes de quatro sistemas de implante-pilar divididos em 8 grupos (n=6): (1) hexágono externo e munhão universal; (2) hexágono externo e munhão universal com CF; (3) cone morse e munhão universal; (4) cone morse e munhão universal com CF; (5) cone morse e munhão universal parafuso passante; (6) cone morse e munhão universal parafuso passante com CF; (7) cônica justaposição e pilar padrão; (8) cônica justaposição e pilar padrão com CF. Os implantes foram fixados em resina epóxica e os pilares acoplados, realizando a pré-carga. Os espécimes (implante-pilar) foram submetidos à ciclagem térmica de 1.000 ciclos a 5°C e 55°C, com permanência de 60 s em cada banho, e à fadiga mecânica de 1,0 milhão de ciclos, 1,0 Hz e 120 N. O ensaio de infiltração bacteriana foi realizado com o microrganismo Streptococcus sanguinis (NCTC 10904). Os espécimes foram imersos em meio Tryptic Soy + Yeast Extract (TY) contendo S. sanguinis e incubados a 37°C e 10% CO2 por 72 h. Os valores de destorque foram registrados e os pilares foram desacoplados. Cone de papel estéril foi esfregado na parte interna do implante, inserido em um tubo contendo meio TY estéril e incubado. A presença de infiltração bacteriana foi avaliada por meio da turbidez do caldo. Implantes e pilares foram avaliados por meio de MEV. Os dados de perda de pré-carga foram submetidos à análise de variância a 2 critérios e ao teste de Tukey. Todos os sistemas apresentaram maiores valores de destorque quando submetidos à CF (p<0,05). O sistema cone morse com munhão universal apresentou os maiores valores de destorque quando comparado aos demais sistemas (p<0,01). Todos os sistemas cônicos apresentaram infiltração bacteriana. Dentro das condições experimentais, o sistema cone morse com munhão universal apresentou os maiores valores de destorque e não foi observado relação entre a perda da précarga e infiltração bacteriana. / Abstract: The presence of microorganisms in the implant and abutment interface is one of the factors associated to the osseointegrated implant failures. Conical junction implant systems have aimed a precise fit between implant and abutment, however, the behavior of these systems it is not known when submitted to the stress environment as found in the oral cavity, related to the preload maintenance and bacterial seal ability. Thus, the aim of this study was to evaluate the preload loss and the bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems, submitted to thermal cycling and mechanical fatigue (TM). Forty eight implants of four different implant-abutment systems were divided in 8 groups (n=6): (1) external hexagon and universal post; (2) external hexagon and universal post with TM; (3) morse taper and universal post; (4) morse taper and universal post with TM; (5) morse taper and universal post two pieces; (6) morse taper and universal post two pieces with TM; (7) locking taper and standard abutment; (8) locking taper and standard abutment with TM. The implants were embedded in epoxy resin and the abutments were connected, setting the preload. The assemblies (implant-abutment) were submitted to thermal cycling of 1.000 cycles at 5°C and 55°C, with a dwell time of 60 s each and to mechanical fatigue, 1.0 million cycles, 1.0 Hz, 120 N. Bacterial penetration assay was performed with Streptococcus sanguinis (NCTC 10904). The assemblies were immersed in Tryptic Soy + Yeast Extract (TY) broth containing S. sanguinis and incubated at 37°C and 10% CO2 for 72 h. Detorque values were recorded and the abutments were disconnected. Sterile paper points were rubbed on the inner part of the implant and inserted in a tube with sterile TY broth and incubated. The presence or absence of bacterial penetration was assessed by the broth turbidity. Implants and abutments were observed by SEM. The preload loss data was analyzed by two-way ANOVA, followed by Tukey test. All the screw systems showed higher detorque values when submitted to TM(p<0,05). The morse taper system with universal post showed the highest detorque values when compared with the other systems (p<0,01). All the conical systems showed bacteria penetration. Within these experimental conditions, the morse taper system with universal post showed the higher detorque values and no relation between the preload loss and the bacterial penetration was observed. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
64

Efeito da aplicação intermitente do PTH (1-34) sobre o tecido osseo ao redor de implantes inseridos em ratas expostas ou não a fumaça de cigarro / Effect of intermittent PTH (1-34) on bone tissue around implants in rats exposed or not to cigarette smoke inalation

Lima, Liana Linhares 15 August 2018 (has links)
Orientadores: Marcio Zaffalon Casati, João Batista Cesar Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T00:47:10Z (GMT). No. of bitstreams: 1 Lima_LianaLinhares_D.pdf: 1779418 bytes, checksum: 5170e97149f324c7dae9d9edd2c763fb (MD5) Previous issue date: 2009 / Resumo: O objetivo do presente estudo foi avaliar histometricamente a influência do PTH (1-34) sobre o reparo ósseo e osseointegração de implantes de titânio instalados em tíbias de ratas expostas ou não à inalação da fumaça de cigarro. Foram utilizadas 61 ratas Wistar adultas aleatoriamente divididas em: grupo 1 (n=15) : animais que receberam a aplicação do veículo necessário para a dissolução do hormônio após a instalação do implante; grupo 2 (n=16) : inalação de fumaça de cigarro (IFC) por 60 dias no pré e pós-operatório da colocação do implante; grupo 3 (n = 17): tratamento do grupo 2 associado à injeções subcutâneas de 40 fxg/kg de PTH sintético (1-34) três vezes por semana, após a colocação do implante e grupo 4 (n=13) : injeções subcutâneas de 40 Hg/kg de PTH sintético (1-34) três vezes por semana após a instalação dos implantes. Os animais foram sacrificados sessenta dias após a colocação dos implantes, secções não descalcificadas foram obtidas e avaliadas histometricamente, segundo os seguintes parâmetros: porcentagem de tecido ósseo em contato direto com a superfície do implante (CD), porcentagem de preenchimento ósseo das roscas do implante (AO) e porcentagem de tecido mineralizado numa zona de 500 um, adjacente à superfície do implante (PTM). Os parâmetros foram obtidos separadamente para região cortical e região medular. Não foram detectadas diferenças entre os grupos que receberam aplicação de PTH (1-34) (Grupos 3 e 4) em todos os parâmetros avaliados (p>0,05). Além disso, o PTH promoveu um aumento significativo no CD, AO e PTM em ambas as regiões, mesmo na presença de IFC (p<0.05) (exceto para AO na região cortical). Uma influência negativa da IFC foi observada para o parâmetro CD na região cortical, uma vez que o grupo 2 apresentou os menores valores de CD, seguidos do grupo 1. Resultados semelhantes foram observados para PTM em ambas as regiões analisadas. Dentro dos limites deste estudo pode-se concluir que a aplicação intermitente de PTH (1-34) é capaz de minimizar os impactos negativos da inalação da fumaça de cigarro na osseointegração de implantes de titânio inseridos em tíbias de ratas. / Abstract: The aim of this study was to investigate the synthetic parathyroid hormone, PTH (1-34), can mitigate the effect of cigarette smoke inhalation (CSI) on the bone healing around titanium implants inserted in rats. 61 female Wistar rats were randomly assigned to one of four groups: group l(n = 15): animals that received the application of the necessary vehicle for the dissolution of the hormone after installation of the implant; group 2 (n = 16): cigarette smoke inhalation (CSI) for 60 days preoperatively and sixty days after implant placement group 3(n = 17), treatment group 2, associated with subcutaneous injections of 40 u-g / kg of synthetic PTH (1-34) three times a week after implant placement and group 4 (n = 13): subcutaneous injections of 40 ug / kg of synthetic PTH (1-34) three times a week after placement of implants. The animals were sacrificed sixty days after the placement of implants, not decalcified sections were obtained and evaluated histometrically, according to the following parameters: percentage of bone tissue in direct contact with the implant surface (BIC), percentage of bone filling the threads of the implant (BF) and percentage of mineralized tissue in an area of 500 urn adjacent to the implant surface (BA). The parameters were obtained separately for the cortical and cancellous bone. No differences were found between the groups that received PTH (1-34) (Groups 3 and 4) in all evaluations (p> 0.05). In addition, PTH (1-34) caused a significant increase in BIC, BF and BA in both regions, even in the presence of CSI (p <0.05) (except for BF in the cortical region). A negative influence of the IFC was observed for the parameter BIC in the cortical region, as group 2 had the lowest values of BIC, followed by group 1. Similar results were observed for BA in both regions analyzed. Within the limits of this study can conclude that the intermittent application of PTH (1-34) is able to reversing the negative effects of cigarette smoke inhalation on osseointegration of titanium implants inserted in rats. / Doutorado / Periodontia / Doutor em Clínica Odontológica
65

Influencia da inclinação da mandibula em medidas do rebordo alveolar em exames de tomografia computadorizada de feixe conico para implantes / Cone beam computed tomography for dental implants : influence of the mandibular positioning on the bone height and widht

Menezes, Alynne Vieira de 06 August 2010 (has links)
Orientador: Solange Maria de Almeida / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T20:48:17Z (GMT). No. of bitstreams: 1 Menezes_AlynneVieirade_D.pdf: 1911461 bytes, checksum: 9eed499fb3fe7db23a7c4de2811423d3 (MD5) Previous issue date: 2010 / Resumo: A utilização de implantes dentários para a reabilitação de regiões edêntulas é uma das atividades mais crescentes da Odontologia e a utilização de imagens é um fator essencial para se alcançar o almejado sucesso. Vários métodos de imagem vêm sendo utilizados com esse propósito e a tomografia computadorizada de feixe cônico (TCFC) vem se estabelecendo como um dos métodos promissores nesse sentido, pois se trata de um método confiável, capaz de produzir imagens em tamanho real, sem sobreposição e com dose de radiação menor que a tomografia computadorizada fan beam. Neste trabalho teve-se como objetivo avaliar a influência da posição da mandíbula na realização de medidas da altura e da espessura de sítios implantares em cortes ortorradiais de TCFC. Para tanto, foram utilizadas 10 mandíbulas maceradas, sendo obtidas imagens utilizando-se o tomógrafo de feixe cônico i-CAT. Foi realizada uma única imagem de cada mandíbula e a partir dessa imagem, os cortes ortorradiais foram obtidos considerando-se 3 diferentes posições: 1: base da mandíbula paralela ao plano horizontal (Posição Normal - PN); 2: base com inclinação de +10° (Posição Superior - PS) e 3: com inclinação de -10° (Posição Inferior - PI). A altura e a espessura óssea de cada região foram mensuradas por um único examinador e os dados obtidos nos grupos experimentais (PS e PI) foram comparados com os dados obtidos do grupo controle (PN) usando a análise de variância two-way (a=0,05). Os valores médios de altura e de espessura ósseas não variaram significativamente entre as posições inclinadas (PS e PI) e a posição padrão (PN), o que permite concluir que nas inclinações avaliadas, a direção do plano axial não influenciou nas medidas obtidas / Abstract: Dental implants have became part of routine treatment plans in many cases of edentulous patients and an important part of preimplant examination is provided by images of the existing bone structures in addition to the clinical findings. Several imaging modalities have been used for preimplant assessment and the cone-beam computed tomography may indeed be the next major advancement, since provides clinicians with accurate images of high diagnostic quality with relatively short scanning times and a reported radiation dose lower than fan beam computed tomography. The aim of this present study was to investigate the influence of mandibular inclination on the measured height and width of the cortical bone in reformatted cross-sectional cone beam computed tomography. Ten human dry mandibles were scanned with dental CBCT (i-CAT). It was performed only one scan of any mandible and reformatted cross-sectional scans were obtained at three different positions: (1) parallel to the lower border of the mandible (standard position); (2) with a inclination of +10° (Upper Position) and (3) with a n inclination of -10°(Lower Position). The alveolar bone height and width were measured for one examiner and data subjected to two-way analysis of variance and to compare the means obtained for the experimental groups (UP and LP) with the control group (standard position) (a=0,05). Mean values of bone height and width did not varied significantly between the inclined (UP and LP) and the standard positions. It could be concluded that in the positions analyzed, the direction of the axial planes did not influence the measurements obtained / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
66

Efeito de duas diferentes rugosidades do intermediário de titânio no aspecto histológico do tecido peri-implantar de pacientes utilizando sobre-dentadura.

Sérgio Kiyoshi Ishikiriama 24 April 2000 (has links)
O sucesso da osseointegração depende, entre outros fatores, da integridade da interface entre os tecidos moles peri-implantares e componente intermediário do implante. Nesta região ocorre um vedamento que separa o meio interno e externo, responsável pela manutenção a longo prazo da osseointegração. Para que este mecanismo ocorra com êxito, é necessário que os tecidos moles possam exercer suas funções normais em um ambiente livre de inflamação e contaminação bacteriana. Levando-se em conta que os intermediários acumulam placa bacteriana devido à sua rugosidade superficial, o presente trabalho objetivou determinar a influência desta rugosidade na inflamação dos tecidos moles peri-implantares. Dois intermediários com diferentes rugosidades (intermediário padrão e polido) foram colocados em dez pacientes portadores de sobre-dentaduras inferiores, retidas por dois implantes do sistema NAPIO, desenvolvido na Faculdade de Odontologia de Bauru – USP, por um período de 3 meses. Após este período, biópsias foram realizadas e analisadas em microscópio de luz comum. A contagem morfométrica celular indicou que os tecidos moles peri-implantares ao redor dos intermediários polidos (grupo teste) apresentaram-se com uma quantidade média significantemente menor de linfócitos, quando comparados ao grupo controle (p<0.05). Portanto, a lisura superficial obtida no processo de polimento utilizado no presente trabalho foi considerada satisfatória no que tange a minimizar a inflamação dos tecidos moles peri-implantares e sugere-se que as superfícies dos intermediários devam ser o mais lisas possível no intuito de facilitar o controle de placa pelo próprio paciente. / The osseointegration success depends on the integrity of the interface between abutment and peri-implant soft tissues. In this region, a seal closes the opening between the oral mucosal and the implant, preventing the ingress of bacteria, plaque and other debris into the tissues of the internal environment and it is responsible for the long term maintenance of osseointegration. To acquire a complete seal, soft tissues must be free of inflammation and bacterial contamination. Since superficial roughness of abutments can facilitate the bacterial plaque accumulation, the aim of the present study was to determine the relation between abutment roughness and soft tissue inflammation. Abutments with 2 different levels of roughness (standard and polished abutment) were installed in 10 pacientes treated with mandibular overdentures anchored by 2 implants (NAPIO). After a period of 3 months, biopsies were removed and analyzed on a light microscope. The cell morfometric results showed that soft tissues around polished abutments harbored significantly less linfocytes than soft tissues around standard abutments. Therefore, the reduced superficial roughness presented on polished abutments successfully minimized the soft tissue inflammation and it is suggested that abutment surface should be as polished as possible to allowed a better plaque control by patients.
67

Avaliação da adaptação vertical entre intermediários do tipo esteticone e cilindros metálicos pré-usinados, variando as condições: sobrefundição, torques e parafusos de fixação

Luciana Martins Crês Moraes 27 August 2003 (has links)
A adaptação de próteses sobre implantes é considerada um fator primordial para o sucesso destas longitudinalmente. Este estudo observou a adaptação vertical entre intermediário tipo esteticone e cilindros pré-fabricados antirotacionais para próteses unitárias em diferentes ligas. Foram selecionados cilindros de ouro da empresa Conexão (Conexão Sistemas de Prótese - São Paulo- SP- Brasil) e cilindros de níquel/cromo pré-fabricados em um laboratório comercial. A mensuração da adaptação vertical foi realizada em microscópio óptico, antes da sobrefundição, ao torque de 10Ncm e 20Ncm variando-se os parafusos de fixação. Encontraram-se medidas que variaram de 14,02 ± 5,63 µm para os cilindros de níquel/cromo, antes da sobrefundição ao torque de 10Ncm, e 10,95 ± 5.68 µm para o torque de 20Ncm. E para os cilindros de ouro, ao torque de 10Ncm, a média encontrada foi de 14,41 ± 3,84 µm e ao torque de 20Ncm foi de 12,26 ± 3.69 µm. Após as leituras iniciais, os cilindros receberam enceramento, foram incluídos e fundidos com ligas de paládio/prata para o cilindro de ouro, e níquel/cromo para o cilindro de níquel/cromo e novamente analisados. As medidas variaram de 20,93 ± 7,10 µm a 10Ncm e 15,77 ± 4,72 µm a 20Ncm para os cilindos de níquel/cromo fundidos em níquel /cromo, e de 11,79 ± 4,06 µm ao torque de 10Ncm e 9,59 ± 3,25 µm à 20Ncm para os cilindros de ouro sobrefundidos em paládio/prata. Os resultados obtidos demonstraram que o cilindros de ouro com maior torque apresentaram-se mais adaptados antes e após a sobrefundição. Foram encontradas diferenças estatisticamentes significantes também quando a liga de paládio/prata foi empregada. Concluiu-se então que as próteses unitárias sobre implantes são indicadas sendo que ligas nobres e seminobres apresentam menores variações estruturais. / The fitting of prostheses over implants is regarded as a fundamental factor for their success in the long-term. This study evaluated the vertical fitting between esteticone abutments and anti-rotational prefabricated cylinder implants of several alloys for single-tooth prosthesis. Gold cylinders of the brand Conexao (Conexao Sistemas de Protese – Sao Paulo, SP, Brazil) and nickel-chromium cylinders prefabricated in a commercial laboratory were selected. Measurement of the vertical fitting was conducted in a light microscope, before overcasting with 10 Ncm and 20 Ncm of torque, with variations in the fixing screws. The measurements ranged from 14.03±5.63µm for the nickel-chromium cylinders before overcasting with 10 Ncm of torque and 10.95±5.68µm with 20 Ncm of torque. Concerning the gold cylinders, the values found were 14.41±3.84µm with 10 Ncm of torque and 12.26±3.69µm with 20 Ncm of torque. After the initial readings, the cylinders were submitted to waxing, investment and casting with palladium-silver alloy for the gold cylinders and nickel-chromium alloy for the nickel-chromium cylinders, and then reevaluated. The measurements revealed 20.93±7.10µm with 10 Ncm and 15.77±4.72µm with 20 Ncm for the nickelchromium cylinders cast with nickel-chromium, and 11.79±4.06µm with 10 Ncm and 9.59±3.25µm with 20 Ncm for the gold cylinder overcast with palladium-silver. The results demonstrated that the gold cylinders with the higher torque exhibited the best fitting before and after overcastting. Statistically significant differences were also observed with employment of the palladium-silver alloy. It was concluded that single-tooth implant-supported prosthesis may be indicated, being that noble and semi noble alloys present the smallest structural variations.
68

Avaliação por elementos finitos de tensões ocorridas em diferentes seções transversais do sistema de retenção de overdenture tipo barra-clipe com desajuste vertical : Evaluation by finite element analysis of stress at different cross-sections design of overdenture's bar framework with vertical misfit / Evaluation by finite element analysis of stress at different cross-sections design of overdenture's bar framework with vertical misfit

Nogueira, Moises da Costa Ferraz, 1989- 06 June 2014 (has links)
Orientadores: Rafael Leonardo Xediek Consani, Mateus Bertolini Fernandes dos Santos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T21:15:14Z (GMT). No. of bitstreams: 1 Nogueira_MoisesdaCostaFerraz_M.pdf: 1749031 bytes, checksum: 8fa4481a045e127aabb629294129a5b0 (MD5) Previous issue date: 2014 / Resumo: O objetivo neste estudo foi avaliar por meio da análise por elemento finito 3-D, as tensões ocorridas em overdentures com sistemas de retenção barra-clipe, quando diferentes formas da seção transversal (circular, ovóide ou Hader) apresentam diferentes níveis de desajuste vertical (50, 100 e 200 µm) e são confeccionadas com diferentes ligas metálicas (Au tipo IV, Ag-Pd, Co-Cr e Ti cp). Modelos tridimensionais foram feitos utilizando software para modelagem 3-D (SolidWorks 2010) e importados para o software de simulação mecânica (ANSYS Workbench 11). Aperto simulado do parafuso foi realizado até obter assentamento adequado entre infraestrutura e plataforma protética. As análises foram realizadas com o objetivo de obter as tensões Máxima Principal e de von Mises (MPa). Os valores da tensão aumentaram com o aumento do desajuste vertical, assim como a barra Hader proporcionou os maiores valores. Barras circulares feitas com Au tipo IV causaram os menores valores na barra e no parafuso protético. Ligas resilientes mostraram melhores resultados que as rígidas, enquanto a maior complexidade da seção transversal da barra e o maior nível de desajuste vertical aumentaram a concentração das tensões na barra, parafuso protético e tecido ósseo cortical. Conclui-se que as tensões induzidas na barra, parafuso protético e tecido ósseo peri-implantar foram influenciadas pelo aumento do desajuste vertical, complexidade da seção transversal e liga da barra / Abstract: The objective of this study was to evaluate by 3-D finite element analysis tensions occurred in overdentures with bar-clip retention systems, when different cross-sectional geometries (circular, oval or Hader) have different levels of vertical misfit (50, 100 and 200 µm) and were maded from different metallic alloys (type IV Au , Ag-Pd , Co-Cr and Ti cp). Three-dimensional models were maded using 3-D modeling software (SolidWorks 2010) and imported into the software of mechanical simulation (ANSYS Workbench 11). A displacement simulating screw tightening was done until proper fitting of the prosthetic platform infrastructure. The analyzes were performed in order to obtain the Maximum Principal Stress and von Mises (MPa). The stress values increased proportionally with the level of vertical misfit and Hader bar showed the highest values. Circular bars made with Au type IV showed the lowest values on the bar and prosthetic screw. Resilient alloys performed better than hard, while the greater complexity of the cross section of the bar and the highest levels of vertical misfit increased stress concentration on the infrastructure of the bar, prosthetic screw and cortical bone tissue. The stress induced on the bar, prosthetic screw and peri-implant bone tissue were influenced by increased vertical misfit, complexity of cross section and different alloys of the bar / Mestrado / Protese Dental / Mestre em Clínica Odontológica
69

Avaliação da força de retenção de sistemas de encaixes para overdentures em função do numero de ciclos de união e separação dos componentes

Botega, Daniela Maffei, 1977- 14 November 2002 (has links)
Orientador : Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:31:26Z (GMT). No. of bitstreams: 1 Botega_DanielaMaffei_M.pdf: 2444917 bytes, checksum: 5e47f571486882534d0a9fc484da1e9e (MD5) Previous issue date: 2002 / Resumo: Este estudo teve como objetivo avaliar a força de retenção de dois sistemas de encaixe para Overdentures em função do número de ciclos de união e separação dos componentes. Foram confeccionadas 20 amostras, divididas em 4 grupos, 5 por grupo: 1) Sistema O'ring; 2) Sistema Barra-Clip (Conexão Sistemas de Prótese); 3) Sistema O'ring; e 4) Sistema Barra-Clip (Lifecore Biomedical). As amostras imersas em saliva artificial foram submetidas ao ensaio de ciclagem mecânica em máquina servohidráulica MTS-81 O, realizando-se 5500 ciclos de inserção e remoção (0,8 Hz). Durante o ensaio, os valores da força de retenção foram monitorados em 4 registros por meio de ensaio de tração, utilizando o programa Test Work for Test Star (1 mm/min), e célula de carga de I kN: 1Q­ retenção inicial; 2Q- após 1500 ciclos; 3Q- após 3000 ciclos; e 4Q- após 5500 ciclos. Os dados obtidos foram submetidos à Análise de Variância e aplicado o teste de Tukey (p<0,05). Os resultados mostraram que o grupo 2 apresentou resultados superiores ao 4, sendo estatisticamente significantes (44,61 N e 18,44 N, respectivamente). O grupo 1 apresentou valores inferiores ao grupo 3, sendo estatisticamente significantes, exceto em 1500 ciclos, onde os valores não apresentaram diferença (13,91 N e 19,75 N, respectivamente). O grupo 2 apresentou valores sempre superiores ao grupo I, sendo estatisticamente significantes (44,61 N e 13,91 N). Os grupos 3 e 4 apresentaram valores semelhantes (19,75 N e 18,44 N). Desse modo, conclui-se que: os sistemas avaliados neste estudo apresentaram valores de força de retenção satisfatórios antes e após ensaio de ciclagem mecânica, sendo os mais elevados apresentados pelo grupo 2; o ensaio simulando 5 anos de inserção e remoção da prótese não provocou diminuição nos valores da força de retenção ou fratura dos componentes / Abstract: The aim of this study was to evaluate the strength of two Overdenture attachments systems according to the number of insertion and removal cycles. Twenty samples were prepared, divided in 4 groups, 5 specimens in each group as follows: 1) O'ring System and 2) Bar and Clip System (Conexão Sistemas de Prótese); 3) O'ring System and 4) Bar and Clip System (Lifecore Biomedical). The samples imersed in artificial saliva were submitted to mechanical test using a servohidraulic machine MTS-810, performing 5500 cycles of insertion and removal (0.8Hz). The retention force values were controled during the test, recording the values in 4 intervals, using the tensile test (Test Works for Test Star), with speed of Imm/min., and load cel of 1 kN: lst- initial; 2nd after 1500 cycles; 3rd- after 3000 cycles; and 4th - after 5500 cycles. Data were statistically analysed by Variance Analysis followed by Tukey's test (p<0.05). The results obtained showed that group 2 had higher values than group 4, showing significant difference (44.61 N and 18.44 N, respectivelly). Group 1 showed lower values when compared with group 3, being statistically significant, except in 1500 cycles, where there was no difference between them (13.91 N and 19.75 N, respectivelly). The values of group 2 were always higher than group 1, being differents (44.61 N and 13.91 N). Groups 3 and 4 showed similar values (19.75 N and 18.44 N). The conclusion is that: the systems evaluated in this study showed satisfactory values of retention force before and after the mechanical test, and the highest values belonged to group 2; the simulation of 5 years of insertion and removal did not cause a decrease in the values of retention or the components' fracture / Mestrado / Protese Dental / Mestre em Clínica Odontológica
70

Analise in vitro da contaminação bacteriana na interface implante/conector protetico em tres sistemas de implantes endosseos

Cravinhos, Julio Cesar de Paulo 03 August 2018 (has links)
Orientador : Renato Mazzonetto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T14:39:35Z (GMT). No. of bitstreams: 1 Cravinhos_JulioCesardePaulo_M.pdf: 1159055 bytes, checksum: f08ec26d27fdeac90561fc608b698f2d (MD5) Previous issue date: 2003 / Mestrado

Page generated in 0.0595 seconds