• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1383
  • 113
  • 47
  • 44
  • 44
  • 43
  • 26
  • 16
  • 13
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 1556
  • 886
  • 745
  • 656
  • 292
  • 235
  • 207
  • 162
  • 156
  • 140
  • 139
  • 138
  • 137
  • 136
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Análise da microbiota dos sulcos dos implantes de pacientes tratados com implantes dentais

Gibaja, Raynier Omar Aldana January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T15:56:56Z (GMT). No. of bitstreams: 0 / O presente trabalho analisa a qualidade da microbiota dos sulcos dos implantes dentais em humanos mediante a análise de material coletado de sulcos subgengivais. Foram analisadas 11 amostras retiradas do sulco subgengival. Os materiais foram incubados em anaerobiose durante sete dias à 37OC. Placas com meio seletivo para Actinobacillus actinomycetemcomitans foram incubadas em jarra com vela. Após o período de incubação as jarras foram abertas. Colônias de espécies diferentes na morfologia colonial foram repicadas para meio BHI, adicionado de hemina e vitamina K; após o crescimento foram caracterizadas quanto ao Gram e ao tipo respiratório. As amostras retiradas dos implantes saudáveis foram colonizados por estreptococos e bastonetes Gram-positivos. as amostras de implantes com perimplantite foram colonizados por bastonetes Gram-negativos e bastonetes Gram-negativos pigmentados de preto, a amostra do implante com mucosite foi colonizado por estreptococos e bastonetes Gram-negativos. Actinobacillus actinomycetemcomitans não foi detectado.
42

Avaliação da influência da velocidade de perfuração na reabsorção óssea ao redor de implantes osseointegrados instalados por meio de cirurgia guiada sem retalho: estudo clínico, radiográfico e histológico

Landázuri Del Barrio, Ricardo Andrés [UNESP] 19 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-19Bitstream added on 2014-06-13T18:43:56Z : No. of bitstreams: 1 landazuridelbarrio_ra_dr_arafo.pdf: 1068855 bytes, checksum: 6b1cfc32b5ec4d0105c7d549652c1515 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo realizado em humanos e animais foi avaliar clínica, radiográfica e histologicamente a influência da velocidade de perfuração no tecido ósseo peri-implantar em implantes instalados com cirurgia guiada sem retalho. No estudo em animais, 30 implantes foram instalados em ambas as tíbias de 15 coelhos com diferentes velocidades de perfuração (Controle – 1500 r.p.m e Teste – 50 r.p.m.) para avaliação histológica de BIC e BA nos períodos de 4, 8 e 12 semanas. Na segunda parte do estudo, foram realizadas 30 perfurações ósseas nas tíbias de 15 coelhos. A distribuição dos grupos foi de acordo com a velocidade de perfuração utilizada na primeira parte do estudo para avaliação histológica nos períodos de 0, 7 e 14 dias. No estudo em humanos, 64 implantes foram instalados com cirurgia guiada sem retalho em 16 mandíbulas edêntulas. Em cada paciente foram instalados 2 implantes utilizando as duas velocidades de perfuração do estudo em coelhos. A avaliação clínica e radiográfica foi realizada durante 1, 3, 6 e 12 meses. No estudo em coelhos, os 2 grupos mostraram regeneração óssea progressiva na região do defeito sem mostrar diferença estatística. Na avaliação do contato osso-implante e área óssea entre as espiras, não foram observadas diferenças significantes entre os grupos. No estudo clínico foi observado um índice de sucesso de 90% após um ano em função. O nível ósseo médio durante o período experimental foi de 0,83 mm. Treze em 16 próteses pré-fabricadas não apresentaram adaptação confirmada por radiografias periapicais digitais. Três implantes de cada grupo foram perdidos durante o período de avaliação de 3 meses. Um dos implantes perdidos foi avaliado mediante histologia e apresentou necrose na região apical. Não foi observada diferença significante entre os grupos com relação ao IP, SS e à avaliação... / The aim of this study was to evaluate clinical, histologic and radiographically the effect of drilling speed on bone tissue around implants installed with flapless guided surgery. Thirty implants were installed in the tibial metaphysis of 15 rabbits with 2 different drilling speed (Control – 1500 r.p.m and Test – 50 r.p.m.). BIC and BA were assessed during 4, 8 and 12 weeks after implant placement. Then, 30 bone defects were performed in the tibial metaphysis of 15 rabbits with the same drilling speed groups. The histologic evaluation was performed at 0, 7 and 14 days. In the clinical study, 64 implants were installed in 16 edentulous mandibles with flapless guided surgery. Two implants per patient were instaled wtih the same protocol and distribution of drilling speed groups of the animal study and they were clinical and radiographically evaluated during 1, 3, 6 and 12 months. In rabbits, both groups showed progressive bone repair around the defect without statistical differences. No differences between groups were showed in terms of bone implant-contact and bone area. The clinical evaluation showed 90% of implant survival during the experimental period. Mean bone level after 12 months of function was 0.83 mm. A radiographically misfit was observed in 13 of 16 patients between abutment and pre-fabricated prostheses. Three implants of both experimental groups were lost during 3 months evaluation. One implant was assessed histologically and showed apical necrotic bone. No statistical difference between groups were showed at PI, BoP and implant stability. Statistically difference (p<0.05) was showed between groups at mean gray level of bone gain and mean area of bone gain and bone loss evaluation. Within the limitations of this study, it can be concluded that the drilling speed do not have effect on bone repair and it did not present alterations on the osseointegration pattern... (Complete abstract click electronic access below)
43

Análise da distribuição de tensões em implantes curtos e coroas longas, através do método de elemento finito 3-D

Cruz, Rafael Evaristo da January 2016 (has links)
Orientador: Prof. Dr. Nelson Luis Barbosa Rebellato / Coorientador: Prof. Dr. Delson João da Costa / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Odontologia. Defesa: Curitiba, 2016 / Inclui referências : f. 37-44;56-58 / Área de concentração / Resumo: Este estudo analisou através do método de elemento finito tridimensional (MEF) a distribuição de tensões mastigatórias sobre implantes curtos com coroas alongadas, na região do elemento 36. Os modelos de implantes utilizados foram: M1- Neodent Titamax WS® 4x5mm e M2 - Neodent Titamax WS® 5x5mm. A análise verificou a distribuição das tensões nos implantes e no tecido ósseo, sob cargas de incidência axial e oblíqua e avaliou a influência da diferença no diâmetro dos implantes sobre a distribuição das tensões mastigatórias. Os resultados mostraram que sob incidência de forças axiais, os modelos analisados obtiveram resultados satisfatórios, sem exceder os limites de resistência do tecido ósseo e os limites de escoamento dos implantes e componentes protéticos envolvidos. Porém, sob incidência de forças oblíquas, os modelos apresentaram picos de tensão que ultrapassaram os limites de resistência do osso, indicando uma possível reabsorção óssea, de maior evidência no modelo M1. Verificamos um excesso de tensão incidindo sobre o terço cervical dos implantes analisados sob força oblíqua, porém de maior intensidade no modelo M1, podendo levar a uma falha estrutural deste implante. Observamos que o fato de aumentar o diâmetro do implante favoreceu a distribuição das tensões mastigatórias, tanto nos implantes como no tecido ósseo. Conclui-se que o uso de implantes de maior diâmetro possuem um melhor desempenho para dissipar as forças e reduzir a tensão no implante e no osso circunjacente, e que forças oblíquas são potencialmente prejudiciais ao sistema implante/osso, principalmente em implantes curtos com coroas superdimensionadas. A indicação no uso de implantes curtos unitários deve ser cautelosa e o planejamento protético deve ser rigoroso, favorecendo as cargas oclusais ou axiais e minimizando as cargas oblíquas. Palavras-chave: Análise de elementos finitos, implantes dentários, força de mordida. / Abstract: This study analyzed through 3-D finite element method (FEM) simulation of the distribution of masticatory tension on short implants with long length crowns, in 36 region. The CAD SolidWorks® 2015 (Dassault Systemes, Solidworks Corps, USA) and the Ansys Workbench® V16. (Ansys Inc., Canonsburg, PA, USA) softwares were used. The selected implant models were: M1- Neodent Titamax WS® 4x5mm and M2 - Neodent Titamax WS® 5x5mm. The files with the models of implants and abutments were provided by Neodent® company, Curitiba, Brazil. The analysis showed the stress distribution in the bone tissue and implants under axial and oblique forces incidence and evaluated the influence of the difference in diameter of the implants on the distribution of masticatory tensions. The results showed that under effect of axial forces, the models achieve satisfactory results, without reaching or exceeding the strength limits in bone tissue, implants and prosthetic components involved. However, under oblique forces, the models showed maximum tension values exceeding the bone strength limits, indicating a possible bone resorption, more evident in M1. An excess of tension was found on the cervical third of implants analyzed under oblique incidence, but a greater intensity in the M1 led to structural failure of the implant. We note that the fact of increasing the diameter of the short implants favored the distribution of masticatory stress both the implants and the bone tissue. We conclude that the use of larger diameter implants have a better performance to dissipate the forces, and reduce the tension in the walls of the implant and the surrounding bone, and oblique forces are potentially harmful to the implant / bone system, especially for short implants with oversized crown. The indication on the use of single short implants should be cautious and prosthetic planning should be strict, favoring the occlusal or axial loads and minimizing the oblique loads. Keywords: Finite element analysis, dental implants, bite force
44

Plataforma regular versus switching: estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e interno

Freitas Júnior, Amilcar Chagas [UNESP] 30 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-30Bitstream added on 2014-06-13T20:25:50Z : No. of bitstreams: 1 freitasjunior_ac_dr_araca.pdf: 626707 bytes, checksum: 01bcfeff181d77eb6eaa682b52483519 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)... / Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below)
45

Ativação de neutrófilos por superfícies de titânio e zircônia

Resende, Roberto Vieira 31 July 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Graduação em Patologia Molecular, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-04-13T21:19:06Z No. of bitstreams: 1 2017_RobertoVieiraResende.pdf: 3460980 bytes, checksum: ee92906dcea8b64da90b6b60babe2513 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-05-09T12:19:05Z (GMT) No. of bitstreams: 1 2017_RobertoVieiraResende.pdf: 3460980 bytes, checksum: ee92906dcea8b64da90b6b60babe2513 (MD5) / Made available in DSpace on 2018-05-09T12:19:05Z (GMT). No. of bitstreams: 1 2017_RobertoVieiraResende.pdf: 3460980 bytes, checksum: ee92906dcea8b64da90b6b60babe2513 (MD5) Previous issue date: 2018-05-09 / Os glóbulos brancos neutrófilos são as primeiras células de defesa a chegar a qualquer local lesionado, seja lesão por processo biológico, seja por trauma acidental ou cirúrgico. No caso de implantes osteointegráveis, os neutrófilos interagem com a superfície dos implantes desencadeando uma série de sinalização. O titânio é reconhecidamente o material de implante mais bem estudado com altos índices de sucesso. Recentemente, a zircônia está tendendo a substituir o titânio, em diversas partes do corpo humano, como material de implante. Foram separados neutrófilos do sangue periférico de 8 doadores, jovens, sadios, do sexo masculino. Esses neutrófilos foram colocados sobre superfícies de titânio, zircônia comum, zircônia sinterizada e polietileno (controle), e incubados por 1 hora, para permitir a ativação. Depois, as amostras foram centrifugadas para testar a adesão dos neutrófilos e descartar aqueles fracamente aderidos. Tanto as amostras quanto o precipitado foram preparadas para microscopia eletrônica de varredura, teste de produção de espécies reativas de oxigênio (NBT lâmina e colorimétrico). Os exames de microscopia mostraram neutrófilos altamente ativados e aderidos às superfícies de titânio, zircônia e zircônia sinterizada. Quanto à produção de EROs, o titânio causou maior produção que a zircônia comum que, por sua vez causou maior produção que a zircônia sinterizada. Pode-se concluir que superfícies de titânio, zircônia e zircônia sinterizada promovem ativação de neutrófilos, que se aderem fortemente a suas superfícies, e produzem espécies reativas de oxigênio. Há necessidades de mais pesquisas para desvendar os mecanismos e mediadores dessa adesão. / Neutrophil white blood cells are the first imune cells to reach any injured part of the human body, when wounded by biological causes, accidental or surgical trauma. In relation to osteointegrated implants, the neutrophils interact with the surface of the implants triggering a series of signaling. Titanium is recognized as the best studied implant material with high success rates. Recently, zirconia was proposed as a substitute to titanium as implant material in different parts of the human body. In our experimental design, neutrophils were separated from the blood of 8 healthy young, male donors. These neutrophils were placed on surfaces of titanium, common zirconia, sintered zirconia and polyethylene (control), and incubated for 1 hour to allow activation. The samples were then centrifuged to test for adhesion of neutrophils and to separate the weakly adhered cells. Both the samples and the precipitate were prepared for scanning electron microscopy, and reactive oxygen species production test (colorimetric and slide NBT). Microscopy studies showed highly activated neutrophils adhering to the surfaces of titanium, zirconia and sintered zirconia. The tests for detection of ROS showed that titanium produced higher level than ordinary zirconia, which showed higher production than sintered zirconia. Conclusions were that titanium, zirconia and sintered zirconia surfaces promote activation of neutrophils, which adhere strongly to their surfaces, and produce Reactive Oxygen Species. There is a need for deep researches to find out the mechanisms and mediators of these adhesion and signaling.
46

Avaliação da prevalência de canais mandibulares bífidos em tomografia computadorizada por feixe cônico

Villaça-Carvalho, Maria Fernanda Lima [UNESP] 12 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-12Bitstream added on 2014-06-13T18:58:43Z : No. of bitstreams: 1 carvalho_mflv_me_sjc.pdf: 376473 bytes, checksum: fd3cb649deb141adcb6ff92fcc6eaeb7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O canal mandibular pode apresentar diferentes morfologias, em alguns casos, existe a presença de um canal acessório chamado bífido. O objetivo deste estudo foi avaliar a prevalência de canais mandibulares bífidos (CMB) por meio de Tomografia Computadorizada por Feixe Cônico (TCFC). Examinaram-se tomografias de 300 pacientes tanto do sexo masculino quanto do feminino, com idade compreendida entre, 25 a 87 anos, submetidos ao exame para avaliação da mandíbula. Os indivíduos foram divididos em dois grupos de acordo com o sexo, GM para o masculino e GF para o feminino, e dois subgrupos de acordo com o lado examinado, D para o direito e E para o esquerdo. Todas as aquisições tomográficas seguiram um mesmo protocolo de aquisição e a análise das imagens se deu num mesmo software. Foram utilizados filtros de imagens associados aos cortes transversais, oblíquos e reconstrução panorâmica para análise do CMB. Realizaram-se análises descritivas dos valores e comparações entre os fatores pelo teste Anova com significância de 95%. Foi possível observar que os CMB ocorreram em 80 casos (26,67%), destes, 39 (48,75%) no sexo masculino e 41 (51,25%) no feminino, não sendo verificadas diferenças nas mensurações comparadas por sexo (masc p=0,788; fem p=0,140) nem por lado acometido (dir p=0,365; esq p=0,412), apesar do direito ter sido mais frequente (66,67%) em ambos os sexos. Desta forma, pode-se concluir que a prevalência dos CMB é significante e não deve ser negligenciada pelos cirurgiões dentistas / The mandibular canal can have different morphologies, in some cases is present a second canal (bifid). The aim of this study was to evaluate the incidence of bifid mandibular canals (BMC) by Cone Beam Computed Tomography (CBCT). Cone beam CT scans of 300 patients, both male and female, aged 25 to 87 years old, who underwent the examination for evaluation of the mandible, were examined. Patients were divided into two groups according to sex, GM for male and GF for females, and two subgroups according to the side examined, R for right and L for left. All tomographic acquisitions were followed by the same protocol and images analysis were made on the same software. Image filters associated with cross-seccional slices, oblique and panoramic reconstruction for the analysis of BMC were used. Analyses of descriptive values and comparisons were made between ANOVA test with a significance of 95%. It was observed that there were 80 cases of BMC (26. 67%), 39 (48. 75%) in male and 41 (51. 25%) in females. There was no difference in measurements compared by sex (p=0.788 male; p=0.140 female) and for the affected side (p=0.365 right, p=0.412 left), although the right side was more frequent (66.67%) in both sexes. Thus, it can be concluded that the incidence of BMC is relevant and should not be overlooked by dentists
47

Avaliação da prevalência de canais mandibulares bífidos em tomografia computadorizada por feixe cônico /

Villaça-Carvalho, Maria Fernanda Lima. January 2012 (has links)
Orientador: Júlio Cézar de Melo Castilho / Banca: Leonardo Marchini / Banca: Rívea Inês Ferreira / Resumo: O canal mandibular pode apresentar diferentes morfologias, em alguns casos, existe a presença de um canal acessório chamado bífido. O objetivo deste estudo foi avaliar a prevalência de canais mandibulares bífidos (CMB) por meio de Tomografia Computadorizada por Feixe Cônico (TCFC). Examinaram-se tomografias de 300 pacientes tanto do sexo masculino quanto do feminino, com idade compreendida entre, 25 a 87 anos, submetidos ao exame para avaliação da mandíbula. Os indivíduos foram divididos em dois grupos de acordo com o sexo, GM para o masculino e GF para o feminino, e dois subgrupos de acordo com o lado examinado, D para o direito e E para o esquerdo. Todas as aquisições tomográficas seguiram um mesmo protocolo de aquisição e a análise das imagens se deu num mesmo software. Foram utilizados filtros de imagens associados aos cortes transversais, oblíquos e reconstrução panorâmica para análise do CMB. Realizaram-se análises descritivas dos valores e comparações entre os fatores pelo teste Anova com significância de 95%. Foi possível observar que os CMB ocorreram em 80 casos (26,67%), destes, 39 (48,75%) no sexo masculino e 41 (51,25%) no feminino, não sendo verificadas diferenças nas mensurações comparadas por sexo (masc p=0,788; fem p=0,140) nem por lado acometido (dir p=0,365; esq p=0,412), apesar do direito ter sido mais frequente (66,67%) em ambos os sexos. Desta forma, pode-se concluir que a prevalência dos CMB é significante e não deve ser negligenciada pelos cirurgiões dentistas / Abstract: The mandibular canal can have different morphologies, in some cases is present a second canal (bifid). The aim of this study was to evaluate the incidence of bifid mandibular canals (BMC) by Cone Beam Computed Tomography (CBCT). Cone beam CT scans of 300 patients, both male and female, aged 25 to 87 years old, who underwent the examination for evaluation of the mandible, were examined. Patients were divided into two groups according to sex, GM for male and GF for females, and two subgroups according to the side examined, R for right and L for left. All tomographic acquisitions were followed by the same protocol and images analysis were made on the same software. Image filters associated with cross-seccional slices, oblique and panoramic reconstruction for the analysis of BMC were used. Analyses of descriptive values and comparisons were made between ANOVA test with a significance of 95%. It was observed that there were 80 cases of BMC (26. 67%), 39 (48. 75%) in male and 41 (51. 25%) in females. There was no difference in measurements compared by sex (p=0.788 male; p=0.140 female) and for the affected side (p=0.365 right, p=0.412 left), although the right side was more frequent (66.67%) in both sexes. Thus, it can be concluded that the incidence of BMC is relevant and should not be overlooked by dentists / Mestre
48

Preparação de superfície bioativa na Liga Ti-7,5Mo para uso em Odontologia /

Escada, Ana Lúcia do Amaral. January 2009 (has links)
Resumo: Titânio e suas ligas têm sido utilizados em Odontologia devido sua biocompatibilidade e excelente resistência a corrosão. Esses metais são cobertos espontaneamente com uma fina camada de óxido em sua superfície quando em contato com o ar. No entanto, essa superfície do titânio é bioinerte e não se fixa quimicamente ao tecido ósseo. A proposta deste trabalho foi avaliar a bioatividade da liga Ti-7,5Mo após tratamento de superfície químico e subseqüente tratamento térmico. Os lingotes foram obtidos a partir de titânio comercialmente puro e molibdênio utilizando um forno a arco voltaico. Depois submetidos a tratamento térmico a 1100ºC por uma hora, resfriados em água, conformados a frio e torneados para obter microestrutura e morfologia próximas aos implantes dentários. A rugosidade média (Ra) foi medida em rugosímetro (1,3 e 2,6Ym) e discos (10 mm de diâmetro e 4 mm de espessura) foram cortados a cada usinagem. As amostras foram divididas em dois grupos de acordo com a rugosidade: Grupo I (1,3Ym) e Grupo II (2,6Ym), e dois sub-grupos (tratamento alcalino e tratamento alcalino + tratamento térmico). Para o tratamento alcalino, as amostras foram imersas em solução aquosa de NaOH a 5M , por 3 dias a 80ºC, lavadas em água destilada e secas a 40ºC por 24h. Para o tratamento térmico, após o tratamento alcalino, as amostras foram aquecidas a 600 ºC por 1h em forno elétrico. Depois, todas as amostras foram imersas em SBF (Simulated Body Fluid) por 7 e 14 dias para a formação de uma camada de apatita na superfície. As superfícies das amostras foram caracterizadas por perfilometria óptica e microscopia eletrônica de varredura. Nas amostras com tratamento alcalino observou-se a formação de um filme poroso de titanato de sódio e após a imersão em SBF, para os mesmos valores de rugosidade, observou-se que um maior período de imersão (14 dias) levou a um... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium and its alloys have been used in dentistry due to their excellent corrosion resistance and biocompatibility. These metals are covered with a thin oxide layer formed spontaneously on their surface when in contact with air. However, titanium coating is bioinert and it cannot bond chemically to bone tissue. The purpose of this work was to evaluate the bioactivity of Ti-7,5Mo alloy after processing, surface chemical treatment and subsequent heat treatment. Ingots were obtained from titanium and molybdenum by using an arc-melting furnace. They were submitted to heat treatment at 1100ºC for one hour, cooled in water, cold worked by swaging and machined with a CNC lathe in order to achieve microstructure and morphology close to those of dental implants. Average roughness (Ra) was measured by roughness meter (1.3 and 2.6Ym) and discs (10 mm in diameter and 4 mm in thickness) were cut for each one. Samples were divided in two groups according to the roughness: Group I (1.3Ym) and Group II (2.6Ym) and two subgroups (with or without heat treatment). They were ultrasonically cleaned with distilled water and acetone, and air dried prior to the surface treatment. For alkaline surface treatment, samples were immersed in aqueous NaOH solution with 5.0M at 80ºC for 3 days, washed with distilled water and dried at 40ºC for 24h. For heat treatment, after the alkaline treatment, samples were heat treated at 600ºC for 1h in a electrical furnace in air. Then, all samples were immersed in SBF (Simulated Body Fluid) for 7 and 14 days to form an apatite layer on the surface. After the immersion time, the samples were carefully washed and dried, and their surfaces were characterized by optical profilometer and scanning electron microscope. Samples with alkaline treatment were observed to form a film of porous sodium titanate and after immersion in SBF, for the same values of roughness... (Complete abstract click electronic access below) / Orientadora: Ana Paula Rosifini Alves Claro / Coorientadora: Maria Cristina Rosifini Alves Rezende / Banca: Carlos Roberto Grandini / Banca: Durval Rodrigues Junior / Mestre
49

Avaliação in vitro da influência de cargas axiais em próteses parciais fixas implanto-suportadas, por meio da extensometria /

Vasconcellos, Luis Gustavo Oliveira de . January 2008 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Renato Sussumu Nishioka / Banca: Diego Klee de Vasconcellos / Resumo: O objetivo deste estudo foi avaliar in vitro, por meio da extensometria, a influência da aplicação de cargas axiais em próteses parciais fixas de 3 elementos, suportadas por implantes de conexão hexágono interno (HI), variando o tipo de cilindro e o ponto de aplicação de carga. Inicialmente foram inseridos, em disposição linear, três implantes de HI em um bloco de poliuretano. Em seguida, pilares protéticos microunit foram conectados aos implantes com torque de 20Ncm, e sobre estes foram parafusados cilindros usinados de Co-Cr e cilindros plásticos, as quais receberam enceramentos padronizados que foram posteriormente fundidos em liga de Co-Cr (n=5). Quatro extensômetros (SG) foram colados na superfície do bloco, tangenciando os implantes visando mensurar a microdeformação peri-implantar no momento da aplicação das cargas. Cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10Ncm e a seguir foi realizada a aplicação de carga axial de 30kg em 5 pontos pré-determinados. Os dados obtidos na extensometria foram submetidos aos testes estatísticos ANOVA e Tukey (α=5%). Os resultados mostraram diferença estatisticamente significante para o ponto de aplicação de carga (p=0,0001), sendo que o ponto B gerou a menor microdeformação (239,49με) e o ponto D a maior microdeformação (442,77με). Com relação ao tipo de cilindro, não foi observada diferença estatisticamente significante (p=0,748). Concluiu-se que o tipo de cilindro não interferiu na magnitude da microdeformação peri-implantar durante a aplicação de cargas axiais e que a localização da aplicação de carga axial influenciou a magnitude desta microdeformação. / Abstract: The aim of this study was to evaluate in vitro, by means of strain gauge analysis, the influence of aplication of axial loading in three-units fixed partial prostheses, supported by implants with internal hexagon connection (IH), varying the type of cylinders, and the point of load application. Three fixtures IH were inserted in linear arrangement, into a polyurethane block. Microunit abutments were connected to implants with torque of 20Ncm. The framework were fabricated as a one piece casting using plastic burn out components and Co-Cr prefabricated cylinders components (n=5). Four strain gauge were bonded around the microunit abutments on block surface to measure the peri-implant microstrain at the time of application of loads. Each framework was tight on the abutments with torque of 10Ncm and then was made the application of axial load of 30kg in 5 points pre-determined. The data obtained in the strain gauge analysis were submitted to the statistical tests ANOVA and Tukey (α=5%). The results showed a statistically significant difference to the point of application of load (p = 0.0001), whereas the point B has generated the lowest microstrain (239.49 με) and the point D has provided the highest microstrain (442.77 με). Regarding the type of cylinder, statistically significant difference was not observed (p = 0.748). It was concluded that the type of cylinder did not interfere on the magnitude of peri implant microstrain during the application of axial loads and that the location of the application of axial load influenced the magnitude of this microstrain. / Mestre
50

Biocompatilibidade in vivo de implantes de titânio submetidos ao processo biomimético /

Machado, Ana Cristina Posch. January 2008 (has links)
Resumo: Propõe-se neste estudo avaliar a neoformação óssea no interior dos poros e ao redor de implantes porosos de titânio, submetidos ao processo biomimético modificado, inseridos em tíbias de coelhos. Foram confeccionados 180 implantes de titânio puro grau 2, com porosidade controlada, obtidos por meio da metalurgia do pó. Noventa implantes foram pré-tratados com solução de NaOH à 130ºC/1h, submetidos à temperatura de 200ºC/1h e posteriormente imersos em fluido corpóreo simulado modificado por 14 dias. Os implantes foram inseridos em 30 coelhos sendo que cada um recebeu 3 implantes tratados na tíbia esquerda e 3 sem tratamento na tíbia direita. Os animais foram sacrificados em 15, 30 e 45 dias após a cirurgia e os fragmentos das tíbias contendo os implantes foram submetidos à análise histológica, histomorfométrica e teste mecânico de cisalhamento. A análise microestrutural das amostras foi realizada por microscopia eletrônica de varredura (MEV), espectrometria por energia dispersiva de raios X (EDS) e espectroscopia Raman e a avaliação da neoformação óssea por microscopia de luz (MO) e MEV, comparando implantes sem tratamento com aqueles submetidos ao tratamento biomimético. O EDS indicou que a superfície do implante após o tratamento biomimético continha principalmente cálcio (Ca) e fósforo (P) além da presença de titânio. A Espectroscopia Raman do implante de titânio, após o tratamento biomimético, indicou pico característico e de grande magnitude a 960cm-1 devido à formação de uma camada de hidroxiapatita. As imagens ao MO e MEV demonstraram que houve neoformação óssea na interface osso-implante e no interior dos poros, inclusive naqueles mais centrais. Observou-se que a porcentagem média de neoformação óssea nos implantes tratados nos três tempos de sacrifício foi maior do que nos implantes não tratados, sendo observada diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study is to define the coating on porous titanium implants submitted to modified biomimetic process and to evaluate bone neoformation inside the porous and around these implants when inserted in tibiae of rabbits. One hundred and eighty pure titanium implants, fabricated by powder metallurgy, were made. Ninety implants were pretreated with NaOH solution at 130ºC/1h and submitted to the temperature of 200ºC/1h and immersed in modified simulated body fluid for 14 days. The implants were inserted in 30 rabbits; each rabbit received 3 treated implants in the left tibia and 3 untreated implants in the right tibia. The animals were sacrificed after 15, 30, and 45 days of surgery and the tibia fragments containing the implants were submitted to histological and histomorphometric analyses and shear strength test. The microstructure analysis of the samples was performed by scanning electron microscope (SEM), energy dispersive spectrometry (EDS) and Raman spectroscopy; the bone neoformation was evaluated by light microscopy (MO) and SEM comparing only sinterized implants with those submitted to biomimetic treatment. The EDS indicated that the implant surface after biomimetic treatment contained mainly calcium (Ca) and phosphorous (P) in addition to the presence of titanium. The Raman spectroscopy of the titanium implant, after biomimetic treatment, indicated the formation of a hydroxyapatite layer due to the characteristic peak and of great magnitude at 960cm-1. The MO and SEM images showed bone neoformation on the interface bone-implant and inside the porous, including the most internal ones. It was observed that the mean percentage of bone neoformation in the treated implants for the three sacrifice periods were higher than the untreated implants, statistically significant for the 15-day period. The mechanical test showed that the coated implants... (Complete abstract, click electronic access below) / Orientador: Yasmin Rodarte Carvalho / Coorientador: Marize Varella de Oliveira / Banca: Yasmin Rodarte Carvalho / Banca: Marize Varella de Oliveira / Banca: Luana Marotta Reis de Vasconcellos / Banca: Paulo Tambasco de Oliveira / Banca: Carlos Alberto Alves Cairo / Banca: Monica Calixto Andrade / Doutor

Page generated in 0.0721 seconds