• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1383
  • 113
  • 47
  • 44
  • 44
  • 43
  • 26
  • 16
  • 13
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 1556
  • 886
  • 745
  • 656
  • 292
  • 235
  • 207
  • 162
  • 156
  • 140
  • 139
  • 138
  • 137
  • 136
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Estudo Metodológico de Avaliação do Crescimento Ósseo ao Redor de Implantes Osseointegrados Através de Microscopia Confocal de Varredura a Laser e Torque de Remoção.

Lourenço Júnior, Evandro de Toledo 20 August 1999 (has links)
A necessidade de uma compreensão cada vez abrangente sobre o fenômeno da osseointegração faz com que os pesquisadores busquem melhorias constantes nos meios de avaliação deste processo cicatricial. Para analisar as características deste fenômeno ao redor de implantes NAPIO inseridos em tíbias de coelhos, foi realizado um duploo acompanhamento pós-operatório (forças de torque e histológico). Sete animais foram usados neste experimento e cada um recebeu a colocação de 2 implantes, um para avaliação histológica e outro para obtençào da força de remoção por torque. Os animais receberam injeções intra-musculares de 3 diferentes marcadores da atividade óssea, tetraciclina, alizarina e calceína em diferentes intervalos de tempo: Dia 0 – 14 implantes em 7 animais; Dia 7 – Tetraciclina em 6 animais Dia 15 - Sacrifício animais 1 e 2 e Alizarina animais 3, 4, 5 e 6; Dia 21 - Alizarina animais 3, 4 5 e 6; Dia 45 - Sacrifício animais 3 e 4 e Calceína animais 5 e 6; Dia 52 - Calceína animais 5 e 6; Dia 90 - Sacrifício animais 5 e 6; Dia 180 - Sacrifício animal 7 (sem marcador); No momento do sacrifício dos animais os implantes para torque foram removidos e os valores obtidos foram registrados: Animal 1 - 7,49 N.cm (15 dias após a inserção); Animal 2 – 7,12 N.cm (15 dias após a inserção) èMédia=7,30 N.cm; Animal 3 – 35,4 N.cm (45 dias após a inserção); Animal 4 – 31,1 N.cm (45 dias após a inserção) èMédia=35,25 N.cm; Animal 5 – 58,1 N.cm (90 dias após a inserção); Animal 6 – 47,2 N.cm (90 dias após a inserção) èMédia=52,65 N.cm; Animal 7 – 79,7 N.cm (180 dias após a inserção); Os implantes para avaliação histológica foram processados pela técnica de Donath e analisados por microscopia confocal a laser, sendo detectada intensa atividade óssea na interface implante/osso. Os resultados demonstraram uma contínua formação óssea circunjacente aos implantes e concomitantemente um aumento da força de remoção por torque à medida que o intervalo de tempo pósinserção aumentou. / Trying to understand osseointegration, many researches look for better means to evaluate this healing process. In order to analysis this healing process around NAPIO implants is rabbits tibia, a double follow-up was done (torque removal forces and histology). Seven animals were used in this study and each one received 2 implants (one for confocal scanning laser microscopy analysis and the other to obtain the removal torque). The animals received 3 bone labelers injections of Tetracicline, Alizarine and Calceine on different intervals. Day 0 - 14 implants on 7 animals Day 7 - Tetracicline on 6 animals (1, 2, 3, 4, 5 and 6); Day 15 - Sacrifice animals 1 and 2, and Alizarine animais 3, 4, 5 and 6; Day 21 - Alizarine on animals 3, 4, 5 and 6; Day 45 - Sacrifice animals 3 and 4; Calceine animals 5 and 6; Day 52 - Calceine on animais 5 and 6; Day 90 - Sacrifice animals 5 and 6; Day 180 - Sacrifice animals 7 (no bone labeler); At the sacrifice moment the torque removal implants were registered: Animal 1 - 7,49 Ncm; Animal 2 – 7,12 Ncm èMean=7,30 Ncm; Animal 3 – 35,4 Ncm; Animal 4 – 31,1 Ncm è Mean =35,25 Ncm Animal 5 – 58,1 Ncm; Animal 6 – 47,2 Ncm è Mean =52,65 Ncm; Animal 7 – 79,7 Ncm; The remaining implants undergone histologic preparation by Donath technique and were submetted to confocal scanning laser microscopy. This analysis demonstrated a great bone activity on bone/implant interface. The results showed a continuous bone formation around implants and na increasing torque removal force at different time intervals.
92

Estudo Metodológico de Avaliação do Crescimento Ósseo ao Redor de Implantes Osseointegrados Através de Microscopia Confocal de Varredura a Laser e Torque de Remoção.

Evandro de Toledo Lourenço Júnior 20 August 1999 (has links)
A necessidade de uma compreensão cada vez abrangente sobre o fenômeno da osseointegração faz com que os pesquisadores busquem melhorias constantes nos meios de avaliação deste processo cicatricial. Para analisar as características deste fenômeno ao redor de implantes NAPIO inseridos em tíbias de coelhos, foi realizado um duploo acompanhamento pós-operatório (forças de torque e histológico). Sete animais foram usados neste experimento e cada um recebeu a colocação de 2 implantes, um para avaliação histológica e outro para obtençào da força de remoção por torque. Os animais receberam injeções intra-musculares de 3 diferentes marcadores da atividade óssea, tetraciclina, alizarina e calceína em diferentes intervalos de tempo: Dia 0 – 14 implantes em 7 animais; Dia 7 – Tetraciclina em 6 animais Dia 15 - Sacrifício animais 1 e 2 e Alizarina animais 3, 4, 5 e 6; Dia 21 - Alizarina animais 3, 4 5 e 6; Dia 45 - Sacrifício animais 3 e 4 e Calceína animais 5 e 6; Dia 52 - Calceína animais 5 e 6; Dia 90 - Sacrifício animais 5 e 6; Dia 180 - Sacrifício animal 7 (sem marcador); No momento do sacrifício dos animais os implantes para torque foram removidos e os valores obtidos foram registrados: Animal 1 - 7,49 N.cm (15 dias após a inserção); Animal 2 – 7,12 N.cm (15 dias após a inserção) èMédia=7,30 N.cm; Animal 3 – 35,4 N.cm (45 dias após a inserção); Animal 4 – 31,1 N.cm (45 dias após a inserção) èMédia=35,25 N.cm; Animal 5 – 58,1 N.cm (90 dias após a inserção); Animal 6 – 47,2 N.cm (90 dias após a inserção) èMédia=52,65 N.cm; Animal 7 – 79,7 N.cm (180 dias após a inserção); Os implantes para avaliação histológica foram processados pela técnica de Donath e analisados por microscopia confocal a laser, sendo detectada intensa atividade óssea na interface implante/osso. Os resultados demonstraram uma contínua formação óssea circunjacente aos implantes e concomitantemente um aumento da força de remoção por torque à medida que o intervalo de tempo pósinserção aumentou. / Trying to understand osseointegration, many researches look for better means to evaluate this healing process. In order to analysis this healing process around NAPIO implants is rabbits tibia, a double follow-up was done (torque removal forces and histology). Seven animals were used in this study and each one received 2 implants (one for confocal scanning laser microscopy analysis and the other to obtain the removal torque). The animals received 3 bone labelers injections of Tetracicline, Alizarine and Calceine on different intervals. Day 0 - 14 implants on 7 animals Day 7 - Tetracicline on 6 animals (1, 2, 3, 4, 5 and 6); Day 15 - Sacrifice animals 1 and 2, and Alizarine animais 3, 4, 5 and 6; Day 21 - Alizarine on animals 3, 4, 5 and 6; Day 45 - Sacrifice animals 3 and 4; Calceine animals 5 and 6; Day 52 - Calceine on animais 5 and 6; Day 90 - Sacrifice animals 5 and 6; Day 180 - Sacrifice animals 7 (no bone labeler); At the sacrifice moment the torque removal implants were registered: Animal 1 - 7,49 Ncm; Animal 2 – 7,12 Ncm èMean=7,30 Ncm; Animal 3 – 35,4 Ncm; Animal 4 – 31,1 Ncm è Mean =35,25 Ncm Animal 5 – 58,1 Ncm; Animal 6 – 47,2 Ncm è Mean =52,65 Ncm; Animal 7 – 79,7 Ncm; The remaining implants undergone histologic preparation by Donath technique and were submetted to confocal scanning laser microscopy. This analysis demonstrated a great bone activity on bone/implant interface. The results showed a continuous bone formation around implants and na increasing torque removal force at different time intervals.
93

Análise histológica, imunoistoquímica e morfométrica de biópsias de tecidos ósseo de pacientes hipertensos compensados /

Fabris, André Luis da Silva. January 2016 (has links)
Orientador: Roberta Okamoto / Coorientador: Leonardo Perez Faverani / Banca: Idelmo Rangel Garcia Junior / Banca: Paulo Roberto Botacin / Banca: Claudio Maldonado Pastori / Banca: Ana Cláudia Rossi / Resumo: Objetivo: O presente estudo objetivou avaliar as características morfométicas, histológicas e imunoistoquímicas do tecido ósseo coletado de pacientes portadores de hipertensão arterial sistêmica compensada pelo uso de medicamentos antagonistas do sistema renina-angiotensina-aldoesterona (SRAA). Materiais e Métodos: Trinta pacientes com indicação para reabilitação por meio de implantes instalados na região posterior de mandíbula foram divididos em dois grupos, seguindo os critérios de inclusão e exclusão previamente estabelecidos. O primeiro grupo não apresentava alterações sistêmicas (GSA) e não fazia uso de qualquer medicação e, o segundo grupo foi composto por pacientes hipertensos diagnosticados e medicados por antagonistas do SRAA (GAS). Durante o procedimento cirúrgico para instalação dos implantes osseointegráveis com superfície texturizada, foram coletados blocos ósseos por meio de biópsia com broca trefina de 3,0mm de diâmetro nos locais de instalação dos implantes. As biópsias coletadas foram separadas para avaliação por microtomografia computadorizada, sendo avaliados os seguintes parâmetros: volume ósseo (BV/TV), percentual de volume ósseo (BV/TV), espessura de trabéculas (Tb.Th), número de trabéculas (Tb.N), separação entre as trabéculas (Tb.S) e porosidade total (Po-tot). Também foi realizada a análise dos cortes histológicos corados por hematoxilina e eosina, bem como a avaliação imunoistoquímica de proteínas que caracterizam as células da linhagem osteoblástica...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objectives: This study aimed to evaluate the morphometric characteristics, histological and immunohistochemical bone tissue collected from patients with hypertension offset by the use of drugs antagonists of the renin angiotensin system. Material and Methods: 30 patients referred for rehabilitation with implants placed in the posterior mandible were divided into two groups, following the criteria of inclusion and exclusion previously established. The first group showed no systemic changes (GSA) and did not use any medication and the second group was composed of diagnosed hypertensive patients treated by RAAS (GAS) antagonists. During the procedure for installation of dental implants with textured surface, they were collected bone blocks through biopsy trephine drill 3.0mm diameter implants in the installation sites. The collected biopsies were separated fo evaluatio by microtomography, being evaluated the following parameters: bone volume (BV / TV), trabecular thickness(Tb.Th), trabecular number (Tb.N), separation of the trabecular (Tb.S) and total porosity (Po-tot). Also the analysis of histological sections stained with hematoxylin and eosin staining was performed as well a the immunohistochemical evaluation of proteins that characterize the cells of osteoblast lineage: Runx2, osteopontin and osteocalcin. Results: For all parameters (BV, BV / TV, Tb.Th, Tb.N, Tb.S and E-tot) were similar in the comparison between GAS and GSA (p> 0.05, t test). The biology of bone tissue to ... (Complete abstract click electronic access below) / Doutor
94

Efeito da teriparatida (PTH 1-34) no reparo ósseo periimplantar em ratos submetidos à orquiectomia / Effect of teriparatide (PTH 1-34) on peri-implantar bone repair in orchiectomized rats

Gomes-Ferreira, Pedro Henrique Silva [UNESP] 20 February 2017 (has links)
Submitted by Pedro Henrique Silva Gomes Ferreira null (pedroferreirabmf@gmail.com) on 2017-02-23T18:22:41Z No. of bitstreams: 1 Dissertação Pedro Final.pdf: 21042558 bytes, checksum: 387d7b1440d58f7ddaf7c3daa6ef4bdc (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-03-02T17:28:49Z (GMT) No. of bitstreams: 1 gomesferreira_phs_me_araca.pdf: 21042558 bytes, checksum: 387d7b1440d58f7ddaf7c3daa6ef4bdc (MD5) / Made available in DSpace on 2017-03-02T17:28:49Z (GMT). No. of bitstreams: 1 gomesferreira_phs_me_araca.pdf: 21042558 bytes, checksum: 387d7b1440d58f7ddaf7c3daa6ef4bdc (MD5) Previous issue date: 2017-02-20 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivos: Avaliar a morfometria e dinâmica óssea periimplantar em ratos submetidos à orquiectomia, tratados com teriparatida. Materiais e Métodos: 18 ratos foram divididos em 3 grupos: SHAM - cirurgia fictícia, ORQ - orquiectomia, e ORQTERI - orquiectomia bilateral, tratados com teriparatida. Cada animal recebeu um implante na metáfise tibial. Aos 14 e 42 dias de pós-operatório, foram administrados os fluorocromos calceína e alizarina, respectivamente. A eutanásia ocorreu ao 60 dias após a instalação dos implantes. As peças foram analisadas na microtomografia computadorizada (microCT) para avaliação dos parâmetros de volume e percentual de volume ósseo (BV, BV/TV), espessura do trabeculado (Tb.Th), número e separação de trabéculas (Tb.N, Tb.Sp) e percentual de porosidade total, (Po-tot). Para microscopia confocal a laser, a mensuração da área dos fluorocromos, da taxa diária de aposição mineral (MAR), da extensão linear de contato osso/implante (ELCOI) e área de osso neoformado (AON), foi realizada no programa Image J. Os dados não paramétricos foram comparados pelo teste Kruskal-Wallis e paramétricos pelo teste ANOVA 1 ou 2 fatores. Como pós-teste, os testes de Holm-Sidak, ou Tukey foram aplicados, com nível de significância a 5%. Resultados: Para os parâmetros BV, BV/TV, Tb.Th, o grupo ORQTERI apresentou os maiores valores em relação aos demais grupos e, para Po-tot, os menores valores foram para o grupo ORQTERI (ORQ: p<0,05 e SHAM: p>0,05). Para Tb.Sp o grupo SHAM apresentou o melhor resultado (ORQ: p<0,05 e ORQTERI: p>0,05), e Tb.N, não houve diferença estatisticamente significante na comparação dos resultados intragrupos (p>0,05). Para MAR e avaliação dos fluorocromos, ORQTERI mostrou melhor turnover ósseo periimplantar (ORQ: p<0,05), para ELCOI e AON, o grupo SHAM apresentou os maiores resultados (ORQ: p<0,05). Conclusões: O tratamento com Teriparatida melhora a dinâmica óssea, além de aumentar o volume e a qualidade do osso periimplantar. / FAPESP: 2015/04649-7
95

Sobrevivência e sucesso de implantes osseointegrados com superfície tratada por ataque ácido: avaliação retrospectiva de 8 a 10 anos /

Nícoli, Lélis Gustavo. January 2014 (has links)
Orientador: Élcio Marcantonio Junior / Co-orientador: Daniela Leal Zandim-Barcelos / Banca: Sérgio Luis Scombatti de Souza / Banca: Roberto Henrique Barbeiro / Resumo: Implantes dentários com superfície tratada por ataque ácido representam uma opção clínica para a reabilitação de regiões edêntulas. No entanto, trabalhos prévios mostram que uma variedade de fatores de risco pode comprometer a longevidade do implante. O objetivo deste estudo foi avaliar retrospectivamente a taxa de sobrevivência e sucesso de implantes com superfície tratada por ataque ácido. A amostra constituiu-se de 183 implantes instalados em 44 pacientes que foram submetidos à reabilitação protética no período de 2003 a 2005. A idade média dos pacientes no momento da instalação dos implantes foi de 50 anos, sendo 18 pacientes do gênero masculino e 26 do gênero feminino. Após exames clínico e radiográfico, foi verificado que apenas 5 implantes (2,7%) foram perdidos em 4 pacientes, 1 na maxila e 4 na mandíbula, e 3 implantes (2,0%) não estavam em função. Dos implantes presentes, 155 (87%) aderiram aos critérios de sucesso e 20 (11%) apresentavam peri-implantite. Os pacientes foram reabilitados com próteses múltiplas e unitárias do tipo parafusadas ou cimentadas. Dentre as reabilitações protéticas, implantes com próteses múltiplas parafusadas apresentaram uma maior porcentagem de peri-implantite (15,3%). Baseado nestes resultados, implantes com superfície tratada com ataque ácido apresentaram uma taxa de sobrevivência de 97% e uma taxa de sucesso de 85% após um período de 8 a 10 anos em função. / Abstract: Rough-surface dental implants are a viable clinical alternative for rehabilitation of edentulous areas. However, previous studies have suggested that a vast array of risk factors may compromise the long-term success rate of dental implants. This retrospective study aimed to evaluate the survival and the success rates of dental implants with an acid-etched surface. 183 implants were performed in 44 patients who received subsequent implant-supported prosthetic treatment between the years of 2003 and 2005. Patient mean-age at the time of implant placement was 50 years. 18 patients were male and 26 female. Clinical and radiographic examination showed that only 5 implants (2,7%) were lost among 4 patients, 1 in the maxilla and 4 in the mandible and that 3 implants (2,0%) were not in function. 155 (87%) of the functioning implants fell under the success criteria employed whereas 20 (11%) of them presented peri-implantitis. Rehabilitation included screw-retained or cemented single crowns and bridges. A higher prevalence of peri-implantitis (15.3%) was noted for screw-retained bridges. Results showed a survival rate of 97,3% and a success rate of 87% for dental implants with an acid-etched surface after 8 to 10 years of loading. / Mestre
96

Estudo, caracterização e teste de uma antena microfabricada

Gomes, Vasco Ferraz de Sales January 2008 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores - Major em Telecomunicações. Faculdade de Engenharia. Universidade do Porto. 2008
97

Estudo das microdeformações geradas ao redor de implantes de hexágono interno com roscas convencionais e implantes com platôs, sob a aplicação de carga vertical

Santos, Vivian Mayumi Miyazaki [UNESP] 24 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-24Bitstream added on 2014-06-13T20:58:50Z : No. of bitstreams: 1 000758021.pdf: 2255697 bytes, checksum: 6788d35fffb3b6caf3a72279e1182869 (MD5) / O objetivo deste estudo foi avaliar a micro deformação ao redor de implantes hexágono interno e implantes com roscas platô sob carregamento vertical. Foram confeccionados 10 blocos de poliuretano com 190X30X12 mm. Na face de menor largura e maior comprimento de cada bloco foi inserido um implante de cada sistema (implante hexágono interno de 4 mm X 8,5 mm e implante platô de 4,5 mm X 8 mm) que depois receberam um pilar com 10 mm de altura. O pilar do implante hexágono interno recebeu torque de 20 N com auxilio de torquímetro manual, enquanto o pilar do implante platô foi inserido no implante com o auxilio de martelete. Quatro extensômetros foram colados ao redor dos implantes. Também foram colados extensômetros na lateral do bloco na região do terço médio e apical dos implantes. Os implantes foram submetidos a uma carga vertical estática de 30 Kg. Os dados foram submetidos a análise estatística ANOVA e Tukey (5%). Foi verificado que houve diferença estatística significante para a região cervical (horizontal) dos implantes em relação à região média e apical (vertical), sendo o P=0.0259. Com o teste Tukey, foi verificado que a região horizontal dos implantes platôs apresentaram uma maior micro deformação em relação a região vertical e da região horizontal e vertical dos implantes hexágono interno. Pode-se concluir que o implante platô demonstrou maior micro deformação do que o implante hexágono interno, a região cervical obteve uma maior concentração de tensões em relação à região do terço médio e apical e que o tipo de conexão pilar/implante interfere na micro deformação distribuída ao redor do implante / The aim of the study was to evaluate the micro strain around internal hexagon implant and plateau screws implant under vertical load. 10 polyurethane blocks were produce with 190X30X12 mm. On the narrower face of each block was inserted in each system implant (internal hexagon implant 4 mm X 8,5 mm and plateau implant 4,5 mm X 8 mm) which then received one abutment with 10 mm high. The internal hexagon abutment received torque of 20 N with aid manual torquemeter and plateau abutment was inserted with surgical mallet. Four strain gauge were bonded around of the implants. Also the strain gauges were bonded in the lateral block in the middle and apical region implants. The implants were subjected to a static vertical load of 30 kg. The data were submitted to ANOVA and Tukey (5%). It was found that there was statistically significant difference for the cervical region (horizontal) of the implants to the middle and apical region (vertical), with P = 0.0259. In the Tukey test, it was found that the horizontal region of the plateau implants was higher micro strain than vertical region of the plateau implants and horizontal and vertical region of the internal hexagon implants. It concluded that the implant had a higher plateau micro strain of the implant internal hexagon, the cervical region showed a higher stress concentration towards the region of the middle and apical, and the connection type abutment/implant interferes with micro strain distributed around the implant
98

Avaliação in vitro da influência de cargas axiais em próteses parciais fixas implanto-suportadas, por meio da extensometria

Vasconcellos, Luis Gustavo Oliveira de [UNESP] 26 June 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-06-26Bitstream added on 2014-06-13T18:35:16Z : No. of bitstreams: 1 vasconcellos_lgo_me_sjc.pdf: 497389 bytes, checksum: d4adcb9c1b4650eff9f123f6b41bceab (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar in vitro, por meio da extensometria, a influência da aplicação de cargas axiais em próteses parciais fixas de 3 elementos, suportadas por implantes de conexão hexágono interno (HI), variando o tipo de cilindro e o ponto de aplicação de carga. Inicialmente foram inseridos, em disposição linear, três implantes de HI em um bloco de poliuretano. Em seguida, pilares protéticos microunit foram conectados aos implantes com torque de 20Ncm, e sobre estes foram parafusados cilindros usinados de Co-Cr e cilindros plásticos, as quais receberam enceramentos padronizados que foram posteriormente fundidos em liga de Co-Cr (n=5). Quatro extensômetros (SG) foram colados na superfície do bloco, tangenciando os implantes visando mensurar a microdeformação peri-implantar no momento da aplicação das cargas. Cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10Ncm e a seguir foi realizada a aplicação de carga axial de 30kg em 5 pontos pré-determinados. Os dados obtidos na extensometria foram submetidos aos testes estatísticos ANOVA e Tukey (α=5%). Os resultados mostraram diferença estatisticamente significante para o ponto de aplicação de carga (p=0,0001), sendo que o ponto B gerou a menor microdeformação (239,49με) e o ponto D a maior microdeformação (442,77με). Com relação ao tipo de cilindro, não foi observada diferença estatisticamente significante (p=0,748). Concluiu-se que o tipo de cilindro não interferiu na magnitude da microdeformação peri-implantar durante a aplicação de cargas axiais e que a localização da aplicação de carga axial influenciou a magnitude desta microdeformação. / The aim of this study was to evaluate in vitro, by means of strain gauge analysis, the influence of aplication of axial loading in three-units fixed partial prostheses, supported by implants with internal hexagon connection (IH), varying the type of cylinders, and the point of load application. Three fixtures IH were inserted in linear arrangement, into a polyurethane block. Microunit abutments were connected to implants with torque of 20Ncm. The framework were fabricated as a one piece casting using plastic burn out components and Co-Cr prefabricated cylinders components (n=5). Four strain gauge were bonded around the microunit abutments on block surface to measure the peri-implant microstrain at the time of application of loads. Each framework was tight on the abutments with torque of 10Ncm and then was made the application of axial load of 30kg in 5 points pre-determined. The data obtained in the strain gauge analysis were submitted to the statistical tests ANOVA and Tukey (α=5%). The results showed a statistically significant difference to the point of application of load (p = 0.0001), whereas the point B has generated the lowest microstrain (239.49 με) and the point D has provided the highest microstrain (442.77 με). Regarding the type of cylinder, statistically significant difference was not observed (p = 0.748). It was concluded that the type of cylinder did not interfere on the magnitude of peri implant microstrain during the application of axial loads and that the location of the application of axial load influenced the magnitude of this microstrain.
99

Manejo de recesiones múltiples y colocación de implante unitario en paciente con demanda estética

Reyna Gutierrez, Julio Enrique, Reyna Gutierrez, Julio Enrique January 2017 (has links)
El documento digital no refiere un asesor / Muestra el tratamiento de recesiones gingivales múltiples y la colocación de un implante unitario en una paciente con alta demanda estética. Una paciente de sexo femenino de 70 años de edad con gingivitis, recesiones gingivales múltiples en la arcada superior y edéntula parcial. / Trabajo académico
100

Efeitos da tela de polipropileno, implantada por inguinotomia, no funículo espermático, epidídimo e testículo de cães / Effects of the polypropylene mesh, placed for inguinotomy, on the spermatic funiculus, epididimus, and testicle of dogs

Paula, Joaquim Ferreira de [UNIFESP] January 2005 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:05:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2005 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Com o objetivo de investigar os efeitos produzidos pela prótese de polipropileno, implantada na parede posterior do canal inguinal, 14 cães, adultos e sem raça definida, pesando entre 12 e 23 Kg, foram igualmente distribuídos em dois grupos de 07 e submetidos a inguinotomia bilateral, porém com colocação de prótese em somente um dos lados (grupo A = tela à esquerda; grupo B = tela à direita). A região contra-lateral com o mesmo tipo de dissecção e sem a colocação da prótese, serviu para comparação. Após 60 dias os animais foram reoperados pela mesma via de acesso, sendo realizada uma avaliação macroscópica bilateral concomitante, seguida da retirada dos funículos espermáticos, epidídimos e testículos para estudo histopatológico. Por meio de microscopia óptica estudou-se a presença de reação inflamatória agudo/crônica no 1/3 proximal do funículo espermático, no corpo do epidídimo e testículo. Nestas mesmas localizações mediu-se, respectivamente, os diâmetros da luz do ducto deferente, ducto do epidídimo e túbulo seminífero. Realizouse a análise morfológica quantitativa dos espermatozóides no epidídimo, e no testículo, das células intersticiais e espermatogênicas. Outros quatro animais, sem qualquer tipo de manipulação cirúrgica prévia, serviram como controle (grupo C). Macroscopicamente havia aderências acentuadas entre a tela e a parede posterior do canal inguinal, e moderada entre o funículo espermático e a tela. Nenhuma aderência foi observada no lado contra-lateral (sem tela), assim como no grupo controle. Ainda no lado com tela, três cães apresentaram uma congestão leve do plexo pampiniforme, sendo que um deles também apresentou uma hidrocele. Microscopicamente, no lado xx que foi implantada a tela, além de uma reação inflamatória do tipo corpo estranho, observou-se também uma reação inflamatória crônica no funículo espermático e ducto deferente em todos os animais. No lado contra-lateral havia uma reação inflamatória crônica em menor grau que do lado com tela em 86% dos funículos espermáticos e em 36% dos ductos deferentes. Três cães apresentaram uma reação inflamatória crônica no epidídimo do lado com tela, sendo que um deles também o apresentou do lado sem tela. Destes três cães, dois apresentaram uma redução dos espermatozóides no epidídimo, sendo que um deles também apresentou uma reação inflamatória crônica focal interessando a face interna da albugínea e um outro, redução acentuada da espermatogênese. No grupo controle um cão apresentou uma reação inflamatória crônica focal e um outro, um micro-abscesso no epidídimo. O cão que apresentou a reação inflamatória crônica focal no epidídimo também apresentou redução dos espermatozóides em ambos os lados. Os diâmetros médios da luz do ducto deferente, do ducto do epidídimo e do túbulo seminífero, do lado com prótese, sem prótese e grupo controle foram, respectivamente, 0,31-0,36-0,37 mm, 0,14-0,15-0,16 mm e 77- 76-78 µ. As conclusões são de que a tela provoca uma maior reação inflamatória no funículo espermático e uma redução na luz do ducto deferente de forma significante, bem como redução acentuada da espermatogênese numa minoria dos animais. / With the aim of investigating the affects produced by the prosthesis of polypropylene implanted in the back wall of the inguinal canal, 14 adult cross-bread dogs, weighing between 12 and 23 kg, were equally divided in two groups of 07 and submitted to the bilateral inguinotomy, however the placement of prosthesis in only one of the side (group A = mesh to the left; group B = mesh to the right). The contralateral region with the same type of the dissection and without the placement of the prosthesis, served for comparison. After 60 days the animals were new operated by the same initial skin incision, being carried out a bilateral macroscopic evaluation by the same time, followed by the retreated of the spermatic funiculus, epididimus and testicle for histological analysis. By means of optical microscope the presence of inflammatory reaction acute/ chronic in the 1/3 proximal of the spermatic funiculus was studied, in the body of the epididimus and testicle. In these same location, the diameters of the luminal of the deferens ductucs, epididimus ductus and seminiferous tubules was measured respectively. The quantitative morphological analysis of the spermatozoom in the epididimus, and in the testicle, of the intersticial and spermatogenic cells was achieved. Four others animals, without any type of the prior surgical manipulation, served as a control (group C). Macroscopically there were marked adhesions between the mesh and posterior wall of the inguinal canal, and moderate between the spermatic funiculus and the mesh. No adhesion was observed in contralateral side (without mesh), as well as in the control group. Still in mesh side, three dogs presented a light congestion of the plexus pampiniform, being that one of them also presented a hydrocele. Microscopically, in the side that was implanted the mesh, beyond of the an foreign body type inflammatory reaction, a chronic inflammatory reaction in the spermatic funiculus and ductus deferens in all the animals. Was also observed in contralateral side there was an inespecific chronic inflammatory reaction in lower grade that by the side with mesh in 86% of the spermatic funiculus and in 36% of the ductus deferens. Three dogs presented a chronic inflammatory reaction in the epididimus in the side with mesh, being that of them also presented in the side without mesh. Two among these three dogs, two presented a reduction of the spermatozoon in the epididimus, being that one of them also presented a focal chronic inflammatory reaction involving the internal side of the albuginea and the other, one micro-abscess in the epididimus. The dog that presented a focal chronic inflammatory reaction in the epididimus also presented an espematozoom reduction in the both side. In one of these sides mesh, there was also marked reduction of the spermatogenesis. The means diameters of the luminal of the ductus deferens, epididimus ductus and of the seminiferous tubules, of prosthesis side, without prosthesis and control group were, respectively, 0,31-0,36-0,37 mm, 0,14-0,15- 0,16 mm and 77-76-78 µ .The conclusions are that the mesh, provokes also an inflammatory reaction in the spermatic funiculus and a reduction in the light of the ductus deferens, significative, as well as accented reduction in the spermatogenesis in the minority of the animals. / BV UNIFESP: Teses e dissertações

Page generated in 0.1049 seconds