• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1383
  • 113
  • 47
  • 44
  • 44
  • 43
  • 26
  • 16
  • 13
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 1556
  • 886
  • 745
  • 656
  • 292
  • 235
  • 207
  • 162
  • 156
  • 140
  • 139
  • 138
  • 137
  • 136
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Efeito de três sistemas de osteotomia - ultrassom cirúrgico, laser Er, Cr: YSGG e sistema rotatório - sobre o processo de osseointegração e reparo de defeitos ósseos em tíbia de ratos: estudo histomorfométrico, imuno-histoquímico e biomecânico

Esteves, Jônatas Caldeira [UNESP] 14 March 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-14Bitstream added on 2015-01-26T13:30:19Z : No. of bitstreams: 1 000805961_20170314.pdf: 349223 bytes, checksum: 448acffc1a9c58492a9b1e664b17feac (MD5) Bitstreams deleted on 2017-03-17T12:38:10Z: 000805961_20170314.pdf,. Added 1 bitstream(s) on 2017-03-17T12:39:09Z : No. of bitstreams: 1 000805961.pdf: 4843456 bytes, checksum: f128a369968d68e92229dadbd28be7df (MD5) / O objetivo deste trabalho foi avaliar o processo de reparo ósseo e a osseointegração de implantes inseridos em leitos cirúrgicos preparados por meio de Brocas Convencionais, Ultrassom Piezoelétrico e LASER Er,Cr:YSGG. Como objetivo secundário, foi testada a habilidade do ultrassom cirúrgico de estumilar a liberação de citocinas e fatores de crescimento ósseo durante o processo de reparo. Para tanto, dois estudos distintos foram conduzidos. No Estudo 1, 144 ratos foram divididos em 3 grupos (Grupos Broca, LASER e Piezo) com 48 animais cada. Mini implantes usinados foram instalados em ambas as tíbias de cada animal em alvéolos cirúrgicos preparados pelos 3 sistemas testados de acordo com o grupo ao qual o animal pertencia Após a intervenção cirúrgica, 8 animais por grupo foram sacrificados aos 0, 3, 7, 14, 30 e 60 dias pós-operatórios.. O implante da tíbia direita foi utilizado para o ensaio de torque de remoção e o da tíbia esquerda, para análise de Contato-Osso-Implante (COI) e Fração de Área Ocupada por Osso (FAOO). No Estudo 2, 174 animais foram divididos nos mesmos grupos experimentais – Broca, Piezo e Laser – com 63, 63 e 48 animais cada, respectivamente. Defeitos ósseos de 2mm de diâmetro foram produzidos na tíbia direita dos animais usando um dos três dispositivos testados de acordo com o grupo ao qual o animal foi designado. Oito animais de cada grupo foram sacrificados aos 0, 3, 7, 14 30 e 60 dias e a cicatrização óssea foi analisada por histomorfometria e detecção imuno-histoquímica de Osteocalcina, Osteoprotegerina, Rankl, Vegf e Caspase-3. Cinco animais dos Grupos Broca e Piezo foram sacrificados aos 3, 7 e 14 dias e o espécimes coletados foram utilizados para análise de PCR quantitativo (Q-PCR). Os resultados do Estudo 1 demonstraram a osseointegração dos implantes no três grupos estudados. No Grupo Broca a formação óssea ocorreu mais precocemente, porém um aumento significativo no... / The aim of this study was to evaluate the bone healing process and osseointegration of implants placed in sockets prepared by conventional Drills, Piezosurgery and Er,Cr:YSGG laser. As a secondary objective we tested the hability of Piezosurgery of enhancing the bone repair by releasing of citokynes and growth factor. Therefore, two different studies were conducted. In study 1, 144 rats were assigned to 3 groups: Groups Drill, Laser and Piezo, with 48 animals in each group. Machined mini-implants were placed in both tibiae of each animal in sockets prepared by the three tested systems, according to the group in which it was assigned. After the surgical procedures, 8 animals were sacrificed postoperatively at 0, 3, 7, 14, 30 and 60 days in each group. The implant of the right tibia was used for removal torque test and the left tibia implant was used for Bone-to-Implant Contact (BIC) and Bone Area Fraction Occupancy (BAFO) analysis. In Study 2, 174 animals were ssigned to the same experimental Goups - Drill, Piezo and Laser – with 63, 63 and 48 animals in each group. Bone defects with 2mm in diameter were created in the righ tibia of each animal using one of the three tested devices according to the group in which it was assigned. Eight animals of each group was sacrificed at 0, 3, 7, 14 , 30 and 60 days and bone healing were analyzed by means of histomorphometry and immunohistochemical detection of Osteocalcin, Osteoprotegerin, Rankl, Vegf and Caspase-3. Also, 5 animals form Gorups Drill and Piezo were sacrificed at 3, 7 and 14 days and the bone samples were used for quantitative PCR (Q-PCR) analysis. Results of Study 1 demonstrated implant osseointegration in all experimental groups. The Group Drill presented early bone formation, however, significant increasing in torque removal values occurred only at 30 days. In Groups Laser and Piezo, removal torque increased early and bone healing around the implant was progressively increased until...
132

Análise comparativa do vocabulário em crianças usuárias de implante coclear

Teixeira, Marina Santos 01 December 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2015-05-19T17:28:29Z No. of bitstreams: 1 2014_MarinaSantosTeixeira.pdf: 1763731 bytes, checksum: d8b615208e672650ece3e3c92d820222 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2015-05-19T21:00:21Z (GMT) No. of bitstreams: 1 2014_MarinaSantosTeixeira.pdf: 1763731 bytes, checksum: d8b615208e672650ece3e3c92d820222 (MD5) / Made available in DSpace on 2015-05-19T21:00:21Z (GMT). No. of bitstreams: 1 2014_MarinaSantosTeixeira.pdf: 1763731 bytes, checksum: d8b615208e672650ece3e3c92d820222 (MD5) / Para maior conhecimento sobre o desenvolvimento das habilidades de linguagem de usuários de Implante Coclear (IC) faz-se necessário a utilização de testes que avaliem a expressão oral destes usuários. O ABFW- Teste de Linguagem Infantil nas Áreas de Fonologia, Vocabulário, Fluência e Pragmática é um teste que avalia também o vocabulário e pode ser usado com essas crianças. Objetivo: Avaliar o vocabulário de crianças usuárias de Implante Coclear. Método: O estudo foi feito com 16 crianças que realizaram a cirurgia de IC entre 08 meses e 04 anos e 04 meses de idade. Cinco grupos foram formados: Grupo 01, 03 crianças com idade auditiva entre 01 ano e 01 ano e 11 meses, usuárias de implante coclear unilateral. Grupo 02, 03 crianças com idade auditiva entre 01 ano e 01 ano e 11 meses de idade, porém com implante bilateral. Grupo 03, 03 crianças com idade auditiva entre 02 anos e 02 anos e 11 meses. Grupo 04, 03 crianças com idade auditiva entre 03 anos e 03 anos e 11 meses. Grupo 05, 04 crianças com idade auditiva entre 04 anos e 04 anos e 11 meses. Resultados: No teste de vocabulário quando se compararam as crianças usuárias de IC, levando em conta a idade de desenvolvimento auditivo cerebral x idade cronológica de crianças ouvintes, todas as crianças usuárias de implante apresentaram desempenho melhor. Na comparação entre crianças com implante unilateral x bilateral, estas últimas demonstraram melhores resultados. Quando comparados o desempenho no teste levando em consideração a idade cronológica tanto das crianças surdas quanto das crianças ouvintes, estas últimas obtiveram melhor desempenho, porém há aproximação de resultados com uso efetivo do IC e presença na reabilitação auditiva. Conclusão: O vocabulário de crianças usuárias de IC deste presente estudo se assemelha ao vocabulário de crianças ouvintes. Com uso efetivo do IC e assiduidade na terapia fonoaudiológica as crianças deficientes auditivas conseguem alcançar seus pares ouvintes aos 05 anos de idade. O teste de vocabulário, embora com resultados preliminares, se mostrou uma medida efetiva para observar as lacunas, controlar e direcionar a terapia fonoaudiológica para o desenvolvimento pleno das habilidades de linguagem e fala destas crianças. ______________________________________________________________________________________________ ABSTRACT / Introduction: In order to have a better knowledge about the development of language skills in cochlear implant (CI) users it is necessary to evaluate the speech of these subjects using appropriate tests. The ABFW- Child Language Test is a tool that relates to various areas: phonology, vocabulary, fluency and pragmatics, and that can be used with cochlear implant users for the purposes of this study.Objective: To evaluate the vocabulary of children who are cochlear implant users. Method: This study evaluated 16 children who had CI surgery between 08 and 52 months of age. The subjects were divided in five groups according to the age at the time of the CI activation, as follows: Group 1: 3 children implanted unilaterally with hearing age between 12 and 23 months of age; Group 2: children implanted bilaterally with hearing age between 12 months and 23 months of age; Group 3: 3 children implanted unilaterally with hearing age between 24 and 35 months of age; Group 4: 3 children implanted unilaterally with hearing age between 36 and 47 months of age and Group 5: 4 children implanted unilaterally with hearing age between 48 years and 59 months of age. Results: In the vocabulary test, when comparing CI users considering the auditory brain development age and the chronological age of normal hearing children, all CI users performed better than the standards for normal hearing children. When comparing children with unilateral and bilateral CI, the bilateral cochlear implant users showed better results. When comparing test performance considering the chronological age, normal hearing children performed better, but the results were similar in CI users that systematically use the device and attend auditory rehabilitation sessions.Conclusion: The vocabulary of CI users in the present study was similar to normal hearing children’s vocabulary. The vocabulary test proved to be an effective measure to observe the gaps in development and helped the conduction of speech therapy in order to achieve the full development of speech and language skills of these children.
133

Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas / Resistance to retention rate for traction systems implants nasal implantorretidas

Lima, Walkiria Mendes de 27 October 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-02-16T14:21:44Z No. of bitstreams: 1 2015_WalkiriaMendesdeLima.pdf: 1739133 bytes, checksum: 63e1d3f7ac1d5eda2a16de45eb6c10b3 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-02-18T17:08:14Z (GMT) No. of bitstreams: 1 2015_WalkiriaMendesdeLima.pdf: 1739133 bytes, checksum: 63e1d3f7ac1d5eda2a16de45eb6c10b3 (MD5) / Made available in DSpace on 2016-02-18T17:08:14Z (GMT). No. of bitstreams: 1 2015_WalkiriaMendesdeLima.pdf: 1739133 bytes, checksum: 63e1d3f7ac1d5eda2a16de45eb6c10b3 (MD5) / Este estudo foi dividido em dois capítulos, o primeiro capítulo objetivou revisar a literatura e estabelecer um comparativo da resistência à tração entre os sistemas de retenção: magneto, barra-clipe e o’ring. A busca foi realizada na base de dados PubMed, utilizando as palavras-chave "prostheses retention, maxillofacial prosthetics, prostheses and implant, traction”. Os critérios de inclusão foram artigos com ano de publicação entre 2005-2015, de pesquisa científica, revisões de literatura, ou ensaios clínicos em inglês. Foram selecionados sete artigos, que traziam em seu conteúdo, a resistência à tração dos sistemas de retenção barra-clipe, o’ring e magneto. Concluiu-se que o sistema de retenção com melhor desempenho de força de tração foi o barra-clipe, seguido do o’ring e magneto. O segundo capítulo foi um estudo in vitro que comparou forças de retenção de três sistemas: o’ring, barra-clipe e magneto, em função da ciclagem mecânica com 2160 ciclos. Os sistemas foram submetidos à análise da resistência à tração pelo equipamento Instron 4411 (USA) antes e após os ciclos mecânicos (1080-2160), realizados no equipamento MTS 810 (USA). Pode-se observar, nos resultados apresentados, que houve diferença estatística significativa, entre o sistema de retenção barra-clipe e os demais. Conclui-se que o sistema barra-clipe apresentou diferença estatística quando comparado à força de retenção do sistema o’ring e magneto. O uso dos três sistemas de retenção estudados está indicado para o uso clínico, sendo que a manutenção do sistema pode não ser necessária até 1080 ciclos. / This study was divided into two chapters, the first chapter aimed to review the literature and to establish a comparison of the tensile strength of the restraint systems: magnet, bar-clip and O-ring. The search was conducted in the PubMed database, using the keywords "retention prostheses, maxillofacial prosthetics, prostheses and implant, traction". Inclusion criteria were articles with year of publication in 2005-2015, scientific research, revisions literature, or clinical trials in English. We selected seven articles, which brought in its content, the tensile strength of the bar-clip restraint systems, O-ring and magnet. It was concluded that the restraint system with better power performance Draw-bar clip was followed by the O-ring and the second magnet section foium vitro study comparing three systems retention forces:. O-ring, and magneto-bar clip on the basis of mechanical cycling at 2160 cycles . The systems were subjected to analysis of tensile strength by Instron equipment 4411 (USA) before and after the mechanical cycles (1080-2160), conducted in 810 MTS (USA) equipment. It can be seen, in our results, there was statistically significant difference between the restraint bar-clip and others. We conclude that the bar-clip system showed statistically significant differences when compared to the O-ring retention system strength and magnet. The use of the three studied restraint systems are suitable for clinical use, and the system maintenance may be required up to 1080 cycles.
134

Plataforma regular versus switching : estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e interno /

Freitas Júnior, Amilcar Chagas. January 2011 (has links)
Orientador: Eduardo Passos Rocha / Banca: Wirley Gonçalves Assunção / Banca: Idelmo Rangel Garcia Júnior / Banca: Paulo Guilherme Coelho / Banca: Paulo Francisco César / Resumo: Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below) / Doutor
135

Efeito da teriparatida (PTH 1-34) no reparo ósseo periimplantar em ratos submetidos à orquiectomia /

Ferreira, Pedro Henrique Silva Gomes. January 2017 (has links)
Orientador: Roberta Okamoto / Coorientador: Leonardo Perez Faverani / Banca: Idelmo Rangel Garcia Junior / Banca: Clóvis Marzola / Resumo: Objetivos: Avaliar a morfometria e dinâmica óssea periimplantar em ratos submetidos à orquiectomia, tratados com teriparatida. Materiais e Métodos: 18 ratos foram divididos em 3 grupos: SHAM - cirurgia fictícia, ORQ - orquiectomia, e ORQTERI - orquiectomia bilateral, tratados com teriparatida. Cada animal recebeu um implante na metáfise tibial. Aos 14 e 42 dias de pós-operatório, foram administrados os fluorocromos calceína e alizarina, respectivamente. A eutanásia ocorreu ao 60 dias após a instalação dos implantes. As peças foram analisadas na microtomografia computadorizada (microCT) para avaliação dos parâmetros de volume e percentual de volume ósseo (BV, BV/TV), espessura do trabeculado (Tb.Th), número e separação de trabéculas (Tb.N, Tb.Sp) e percentual de porosidade total, (Po-tot). Para microscopia confocal a laser, a mensuração da área dos fluorocromos, da taxa diária de aposição mineral (MAR), da extensão linear de contato osso/implante (ELCOI) e área de osso neoformado (AON), foi realizada no programa Image J. Os dados não paramétricos foram comparados pelo teste Kruskal-Wallis e paramétricos pelo teste ANOVA 1 ou 2 fatores. Como pós-teste, os testes de Holm-Sidak, ou Tukey foram aplicados, com nível de significância a 5%. Resultados: Para os parâmetros BV, BV/TV, Tb.Th, o grupo ORQTERI apresentou os maiores valores em relação aos demais grupos e, para Po-tot, os menores valores foram para o grupo ORQTERI (ORQ: p<0,05 e SHAM: p>0,05). Para Tb.Sp o grupo SHAM apres... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objectives: To evaluate morphometry and peri-implant bone dynamics in rats submitted to orchiectomy, treated with teriparatide. Materials and Methods: 18 rats were divided into 3 groups: SHAM - fictitious surgery, ORQ - orchiectomy, and ORQTERI - bilateral orchiectomy, treated with teriparatide. Each animal received an implant in the tibial metaphysis. At the 14 and 42 postoperative days, calcein and alizarin were administered, respectively. Euthanasia occurred 60 days after implant installation. The pieces were analyzed by computerized microtomography (microCT) for evaluation of volume and percentage of bone volume (BV, BV/TV), trabecular thickness (Tb.Th), number and separation of trabeculae (Tb.N, Tb.Sp) and percentage of total porosity, (Po-tot). For laser confocal microscopy, the area of the fluorochromes, the mineral apposition rate (MAR), the linear bone implant contact (ELCOI) and the newly formed bone area (AON) were measured in Image J. The nonparametric data were compared by the Kruskal-Wallis test and parametric by the ANOVA 1 or 2 factor test. As a post-test, the Holm-Sidak or Tukey tests were applied, with significance level at 5%. Results: For the parameters BV, BV/TV, Tb.Th, the ORQTERI group presented the highest values in relation to the other groups and, for Po-tot, the lowest values were for the ORQTERI group (ORQ: p <0.05 and SHAM: p> 0.05). For !27 Tb.Sp the SHAM group presented the best result (ORQ: p<0.05 and ORQTERI: p>0.05), and Tb.N, there was no statistically significant difference in the comparison of intragroup results (p>0.05). For MAR and fluorochemical evaluation, ORQTERI showed better peri-implantar bone turnover (ORQ: p <0.05), for ELCOI and AON, the SHAM group presented the highest results (ORQ: p <0.05). Conclusions: Treatment with Teriparatide improves bone dynamics, in addition to increasing the volume and quality of peri-implant bone / Mestre
136

Avaliação da manutenção óssea em implantes instalados a partir da abordagem trimodal: acompanhamento de 1-4 anos

Sczepanik, Fábio Sá Carneiro January 2015 (has links)
Made available in DSpace on 2015-05-29T12:51:02Z (GMT). No. of bitstreams: 1 000469538-Texto+Completo-0.pdf: 1770446 bytes, checksum: 90b8e8696e775e37ea2dd8f6aec011bc (MD5) Previous issue date: 2015 / Purpose : The purpose of this retrospective investigation was to evaluate, radiographically and clinically, a group of patients treated with immediate single-tooth placement, immediate restoration implants with a customized definitive abutment with a flapless approach in the area between both maxillary canines. Marginal bone level (MBL) and marginal bone level of neighboring teeth (MBLN) were assessed.Methods : A sample of 20 subjects received 20 tapered platform-switching implants using a minimally invasive surgery (trimodal approach). The mean age was 55. 2 years (range 25 - 71 years), and the mean follow-up period was 2. 2 years (range 12 - 48 months).Results : The overall treatment survival was 100%. There was no statistically significant difference between MBLN in both mesial and distal aspects, comparing baseline to final follow-up and between the four radiographs independently (i. e. , at baseline, at 06 months, at 12 months, and at final follow-up). There was a statistically significant difference between MBL in both mesial and distal aspects at baseline and at final follow-up (p<0. 05).Conclusion : Within the limitations of this study, it has demonstrated that the trimodal approach might offer an advantage in terms of marginal bone levels, especially in MBLN, in a mean follow-up time of 26 months. Additionally, reduced overall treatment time, one surgical intervention, and immediate esthetics can be obtained with 100% survival and success rates using a minimally invasive approach. / Objetivos : O objetivo desta investigação retrospectiva foi avaliar, radiograficamente e clinicamente, um grupo de pacientes tratados com instalação imediata de implantes unitários, provisório imediato com um pilar protético personalizado, com uma abordagem sem descolamento de retalho mucoperiostal na região ântero superior. Nível da crista óssea marginal e crista óssea marginal a nível dos dentes adjacentes foram avaliados.Materiais e métodos : Uma amostra de 20 indivíduos recebeu 20 implantes cônicos com mudança de plataforma através de uma abordagem minimamente invasiva (abordagem trimodal). A média de idade foi de 55,2 anos (variando de 25 a 71 anos) e o período médio de acompanhamento foi de 2,2 anos (variando de 12 a 48 meses).Resultados : A taxa total de sobrevivência dos implantes e coroas definitivas foi de 100%. Não houve diferença estatisticamente significativa entre MBLN nas faces mesial e distal, comparando-se baseline ao controle final, assim como não houve entre as quatro radiografias independentemente (i. e. baseline, 6 meses, 12 meses e controle final). Houve diferença estatisticamente significativa entre MBL nas faces mesial e distal entre baseline e o controle final (p<0,05).Conclusão : Dentro das limitações deste estudo, demonstramos que a abordagem trimodal pode oferecer uma vantagem em termos de níveis de crista óssea marginal, especialmente em MBLN, durante um período médio de acompanhamento de 26 meses. Adicionalmente, reduzido tempo total de tratamento, apenas uma etapa cirúrgica e estética imediata podem ser obtidos com 100% de taxas de sobrevivência e sucesso, utilizando uma abordagem minimamente invasiva.
137

Estudo das microdeformações geradas ao redor de implantes de hexágono interno com roscas convencionais e implantes com platôs, sob a aplicação de carga vertical /

Santos, Vivian Mayumi Miyazaki. January 2013 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Eduardo Shigueyuki Uemura / Banca: Luis Gustavo de Oliveira Vasconcellos / Resumo: O objetivo deste estudo foi avaliar a micro deformação ao redor de implantes hexágono interno e implantes com roscas platô sob carregamento vertical. Foram confeccionados 10 blocos de poliuretano com 190X30X12 mm. Na face de menor largura e maior comprimento de cada bloco foi inserido um implante de cada sistema (implante hexágono interno de 4 mm X 8,5 mm e implante platô de 4,5 mm X 8 mm) que depois receberam um pilar com 10 mm de altura. O pilar do implante hexágono interno recebeu torque de 20 N com auxilio de torquímetro manual, enquanto o pilar do implante platô foi inserido no implante com o auxilio de martelete. Quatro extensômetros foram colados ao redor dos implantes. Também foram colados extensômetros na lateral do bloco na região do terço médio e apical dos implantes. Os implantes foram submetidos a uma carga vertical estática de 30 Kg. Os dados foram submetidos a análise estatística ANOVA e Tukey (5%). Foi verificado que houve diferença estatística significante para a região cervical (horizontal) dos implantes em relação à região média e apical (vertical), sendo o P=0.0259. Com o teste Tukey, foi verificado que a região horizontal dos implantes platôs apresentaram uma maior micro deformação em relação a região vertical e da região horizontal e vertical dos implantes hexágono interno. Pode-se concluir que o implante platô demonstrou maior micro deformação do que o implante hexágono interno, a região cervical obteve uma maior concentração de tensões em relação à região do terço médio e apical e que o tipo de conexão pilar/implante interfere na micro deformação distribuída ao redor do implante / Abstract: The aim of the study was to evaluate the micro strain around internal hexagon implant and plateau screws implant under vertical load. 10 polyurethane blocks were produce with 190X30X12 mm. On the narrower face of each block was inserted in each system implant (internal hexagon implant 4 mm X 8,5 mm and plateau implant 4,5 mm X 8 mm) which then received one abutment with 10 mm high. The internal hexagon abutment received torque of 20 N with aid manual torquemeter and plateau abutment was inserted with surgical mallet. Four strain gauge were bonded around of the implants. Also the strain gauges were bonded in the lateral block in the middle and apical region implants. The implants were subjected to a static vertical load of 30 kg. The data were submitted to ANOVA and Tukey (5%). It was found that there was statistically significant difference for the cervical region (horizontal) of the implants to the middle and apical region (vertical), with P = 0.0259. In the Tukey test, it was found that the horizontal region of the plateau implants was higher micro strain than vertical region of the plateau implants and horizontal and vertical region of the internal hexagon implants. It concluded that the implant had a higher plateau micro strain of the implant internal hexagon, the cervical region showed a higher stress concentration towards the region of the middle and apical, and the connection type abutment/implant interferes with micro strain distributed around the implant / Mestre
138

Influência da deposição de filmes de carbono tipo diamante na infiltração bacteriana pela interface entre implantes e pilares protéticos /

Cardoso, Mayra. January 2013 (has links)
Orientador: Lafayette Nogueira Junior / Co-orientador: Argemiro Soares da Silva Sobrinho / Banca: Cristiane Yumi Koga-Ito / Banca: Luiz Carlos Santiago da Costa / Banca: Marcos Massi / Banca : Nelson Luiz de Macedo / Resumo: O estudo avaliou a influência da deposição de filmes de DLC na infiltração bacteriana pela interface entre pilares protéticos e implantes de hexágono externo (HE) e interno (HI). Também avaliou a aderência microbiana a estes filmes, depositados sobre titânio. A deposição dos filmes foi realizada por PECVD (Deposição Química a Vapor Assistida por Plasma), e sua caracterização foi feita pelas análises de perfilometria mecânica, espectroscopia Raman, rugosidade, análise tribológica, espectroscopia de energia dispersiva e ângulo de contato. Para avaliação da aderência microbiana, lâminas de titânio (N=45; n=15) foram divididas em três grupos: (1) sem filme (controle); (2) com filme de DLC; e (3) com filme de DLC dopado com prata (DLC-Ag). Elas foram suspensas em poços contendo saliva-glicerol e caldo de cultura. Após 48 h de incubação, elas foram agitadas em ultrassom e a suspensão resultante foi diluída e semeada em placas para contagem de microrganismos. Para avaliação da infiltração bacteriana pela interface implante/pilar, conjuntos de implantes e pilares HE e HI (N=180; n=30) foram divididos de acordo com o tratamento da base do pilar: (1) nenhum tratamento (controle); (2) deposição de filme de DLC; e (3) deposição de filme de DLC-Ag. Sob condições assépticas, foi inoculado 1 μL de suspensão de Enterococcus faecalis no interior dos implantes, e os pilares foram parafusados com 20 Ncm. Os conjuntos foram testados para contaminação externa imediata, suspensos em tubos de ensaio contendo caldo de cultura estéril, e acompanhados por cinco dias. A turvação do caldo indicou infiltração bacteriana. Ao final do período, os pilares foram desparafusados e o conteúdo interno dos implantes foi coletado com cone de papel e semeado em placas de Petri. Estas foram levadas a estufa bacteriológica por 24 h para verificação da viabilidade bacteriana.... / Abstract: This study evaluated the influence of DLC films on bacterial leakage through the interface between abutments and dental implants of external hexagon (HE) and internal hexagon (HI). It also evaluated microbial adhesion to these films deposited on titanium. The deposition of the films was performed by PECVD (Plasma Enhanced Chemical Vapor Deposition), and its characterizations were done by mechanical profilometry, Raman spectroscopy, surface roughness, tribological analysis, energy dispersive spectroscopy and contact angle. To evaluate the microbial adhesion, titanium blades (N=45, n=15) were divided into three groups: (1) without film (control), (2) with DLC film, and (3) with DLC film doped with silver (Ag-DLC). They were suspended in wells containing saliva-glycerol broth. After 48 h incubation they were ultrasonicated and the resulting suspension was diluted and plated for CFU counting. For evaluation of bacterial leakage through implant/abutment interface, sets of implants and abutments (N=180, n=30) were divided according to the treatment of the base of the abutment: (1) no treatment (control); (2) deposition of DLC film, and (3) deposition of Ag-DLC film. Under aseptic conditions, 1 μL of Enterococcus faecalis was inoculated inside the implants, and abutments were tightened to 20 Ncm. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed for five days. The turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper cone and seeded in Petri dishes. These were incubated for 24 h for assessment of bacterial viability and CFU counting. The roughness and log10CFU/mL data were analyzed by analysis of variance. The bacterial leakage was analyzed by Chi-square test, Fisher exact test, Kaplan-Meier and .... / Doutor
139

Efeito de três sistemas de osteotomia - ultrassom cirúrgico, laser Er, Cr: YSGG e sistema rotatório - sobre o processo de osseointegração e reparo de defeitos ósseos em tíbia de ratos : estudo histomorfométrico, imuno-histoquímico e biomecânico /

Esteves, Jônatas Caldeira. January 2014 (has links)
Orientador: Elcio Marcantonio Junior / Banca: Roberto Henrique Barbeiro / Banca: Wilson Roberto Poi / Banca: Thalita Pereira Queiroz / Banca: Paulo Tambasco de Oliveira / Resumo: O objetivo deste trabalho foi avaliar o processo de reparo ósseo e a osseointegração de implantes inseridos em leitos cirúrgicos preparados por meio de Brocas Convencionais, Ultrassom Piezoelétrico e LASER Er,Cr:YSGG. Como objetivo secundário, foi testada a habilidade do ultrassom cirúrgico de estumilar a liberação de citocinas e fatores de crescimento ósseo durante o processo de reparo. Para tanto, dois estudos distintos foram conduzidos. No Estudo 1, 144 ratos foram divididos em 3 grupos (Grupos Broca, LASER e Piezo) com 48 animais cada. Mini implantes usinados foram instalados em ambas as tíbias de cada animal em alvéolos cirúrgicos preparados pelos 3 sistemas testados de acordo com o grupo ao qual o animal pertencia Após a intervenção cirúrgica, 8 animais por grupo foram sacrificados aos 0, 3, 7, 14, 30 e 60 dias pós-operatórios.. O implante da tíbia direita foi utilizado para o ensaio de torque de remoção e o da tíbia esquerda, para análise de Contato-Osso-Implante (COI) e Fração de Área Ocupada por Osso (FAOO). No Estudo 2, 174 animais foram divididos nos mesmos grupos experimentais - Broca, Piezo e Laser - com 63, 63 e 48 animais cada, respectivamente. Defeitos ósseos de 2mm de diâmetro foram produzidos na tíbia direita dos animais usando um dos três dispositivos testados de acordo com o grupo ao qual o animal foi designado. Oito animais de cada grupo foram sacrificados aos 0, 3, 7, 14 30 e 60 dias e a cicatrização óssea foi analisada por histomorfometria e detecção imuno-histoquímica de Osteocalcina, Osteoprotegerina, Rankl, Vegf e Caspase-3. Cinco animais dos Grupos Broca e Piezo foram sacrificados aos 3, 7 e 14 dias e o espécimes coletados foram utilizados para análise de PCR quantitativo (Q-PCR). Os resultados do Estudo 1 demonstraram a osseointegração dos implantes no três grupos estudados. No Grupo Broca a formação óssea ocorreu mais precocemente, porém um aumento significativo no... / Abstract: The aim of this study was to evaluate the bone healing process and osseointegration of implants placed in sockets prepared by conventional Drills, Piezosurgery and Er,Cr:YSGG laser. As a secondary objective we tested the hability of Piezosurgery of enhancing the bone repair by releasing of citokynes and growth factor. Therefore, two different studies were conducted. In study 1, 144 rats were assigned to 3 groups: Groups Drill, Laser and Piezo, with 48 animals in each group. Machined mini-implants were placed in both tibiae of each animal in sockets prepared by the three tested systems, according to the group in which it was assigned. After the surgical procedures, 8 animals were sacrificed postoperatively at 0, 3, 7, 14, 30 and 60 days in each group. The implant of the right tibia was used for removal torque test and the left tibia implant was used for Bone-to-Implant Contact (BIC) and Bone Area Fraction Occupancy (BAFO) analysis. In Study 2, 174 animals were ssigned to the same experimental Goups - Drill, Piezo and Laser - with 63, 63 and 48 animals in each group. Bone defects with 2mm in diameter were created in the righ tibia of each animal using one of the three tested devices according to the group in which it was assigned. Eight animals of each group was sacrificed at 0, 3, 7, 14 , 30 and 60 days and bone healing were analyzed by means of histomorphometry and immunohistochemical detection of Osteocalcin, Osteoprotegerin, Rankl, Vegf and Caspase-3. Also, 5 animals form Gorups Drill and Piezo were sacrificed at 3, 7 and 14 days and the bone samples were used for quantitative PCR (Q-PCR) analysis. Results of Study 1 demonstrated implant osseointegration in all experimental groups. The Group Drill presented early bone formation, however, significant increasing in torque removal values occurred only at 30 days. In Groups Laser and Piezo, removal torque increased early and bone healing around the implant was progressively increased until... / Doutor
140

Influência dos tratamentos térmicos na microestrutura e nos micromecanismos de fratura da liga ti-6al-4v produzida por sinterização direta de metal por laser (DMLS) /

Roque, Lidiane Kümpel. January 2015 (has links)
Orientador: Ruís Camargo Tokimatsu / Co-orientador: Maria Aparecida Larosa / Banca: Vicente Afonso Ventrella / Banca: Cecília Amelia de Carvalho Zavaglia / Resumo: A liga Ti-6A-4V é um biomaterial que tem se mostrado muito adequado na fabricação de implantes para reparar lesões craniofaciais. Entre outros requisitos, é importante que o implante resista a solicitação mecânica para garantir uma resposta clínica satisfatória de modo a proporcionar conforto e segurança ao paciente. O propósito específico do presente trabalho de pesquisa é determinar a influência de diferentes ciclos térmicos na microestrutura da amostra da Ti-6Al-4V produzida pelo processo de sinterização direta de metal por laser (DMLS) e no micromecanismo de fratura resultante de tensionamento uniaxial em tração. Para isso foram fabricados corpos-de-prova de tração, utilizando a técnica DMLS, e os mesmos foram submetidos a diferentes ciclos térmicos de 650 °C/1h, 650 °C/3h, 800 °C/4h e 850 °C/2h. Posteriormente, os corpos-de-prova foram submetidos a ensaios de tração. A caracterização microestrutural foi realizada com auxílio de microscopia óptica (MO) e eletrônica de varredura (MEV). As superfícies de fratura resultantes para as diferentes condições de ciclos térmicos foram analisadas por microscopia eletrônica de varredura. A microestrutura final da amostra como produzida resultante do processo de manufatura aditiva por DMLS revelou uma microestrutura martensita hexagonal α'. Para a amostra A6501H, a microestrutura martensítica resultante do processo DMLS não se decompôs. Na amostra A6503H a microestrutura martensítica começa a se decompor, pois são observados precipitados da fase β. Já nas amostras A8004H e A8502H observa-se uma estrutura (α +β), com cristais de fase α e fase β precipitada nos contornos. De acordo com a análise fractográfica todas as condições estudadas apresentaram fratura dúctil caracterizada pela formação e coalescência de microcavidades com forma e tamanhos variados / Abstract: The Ti-6A-4V alloy is a biomaterial that has proved very suitable for the manufacture of prostheses to repair craniofacial injuries. Among other requirements, it is important that the prosthesis resist mechanical stress to ensure a satisfactory clinical response in order to provide comfort and safety to patients. The specific purpose of this research is to determine the influence of thermal cycles - as prototyped, 650 °C (1h); 650 °C (3h), 800 °C (2h) and 850 °C (4h) - on the microstructure and fracture micromechanisms resulting from uniaxial tension in traction. Therefore it was manufactured by DMLS technique bodies - of - proof traction which were subsequently subjected to different thermal cycles. Then, the bodies -specimens were subjected to tensile test. Microstructural characterization was carried out using optical and scanning electron microscopy (SEM). The resulting fracture surfaces of the five conditions for thermal cycling were analyzed by SEM. The final sample microstructure produced as a result of the additive manufacturing process DMLS revealed a hexagonal martensitic microstructure α '. For A6501H sample, the resulting martensitic microstructure DMLS process is not decomposed. In A6503H martensitic microstructure sample begins to decompose, as are observed precipitates of β phase. Already in the samples A8004H and A8502H observe a structure (α + β) with α and β phase crystal phase precipitated in the contours. According to fractographic analysis of all studied showed ductile fracture conditions characterized by the formation and coalescence wells with varying shape and sizes / Mestre

Page generated in 0.0641 seconds