Spelling suggestions: "subject:"implantes"" "subject:"aimplantes""
161 |
Estudio comparativo de tres métodos antopométricos para determinar la posición de los caninos en maxilar superiorMeléndez Rivero, Katherine January 2007 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Autor no autoriza el acceso a texto completo de su documento / El objetivo de este estudio fue comparar la capacidad de tres métodos
antropométricos para determinar la posición de los caninos superiores en una población
eugnásica. Fueron seleccionados tres relaciones antropométricas presentes en la
literatura que permitirían la ubicación del canino en el desdentado total. Las relaciones
seleccionadas fueron: Relación de Schiffman, Relación de Grove y Cristensen y
Relación establecida por el método BPS (Sistema Protésico Biofuncional). Se
obtuvieron 50 modelos de yeso del maxilar superior provenientes de pacientes que
presentaran un mínimo de catorce dientes en este sector, que fueran aceptables desde el
aspecto estético (sin migraciones, diastemas ni rotaciones). Tres observadores
independientes aplicaron las tres relaciones en ocasiones diferentes sobre los modelos
obtenidos previamente. Las mediciones obtenidas fueron promediadas y analizadas.
Se procedió a evaluar mediante la variable dicotómica cumple o no cumple el
porcentaje de éxito de las relaciones aplicadas según lo definido por los autores y lo
presente en las literatura referente al tema. La significancia de las diferencias entre los
métodos para estos porcentajes fueron evaluados mediante diferencia de proporciones
(p<0.05). Luego se procedió a analizar la distribución y los promedios de los resultados
en milímetros.
Schiffman presentó un porcentaje de éxito de 71% (n=71) con un promedio para
las mediciones de 0.94 mm hacia anterior de la cúspide y 0.97 mm hacia posterior de
ésta. Grove y Christensen presentó un porcentaje de éxito de 67% (n=67) con un
promedio para las mediciones de 0.6 mm hacia anterior del punto de contacto distal y
1.36 mm hacia posterior de éste. La relación del método BPS con respecto a la cúspide
presentó un porcentaje de éxito de 13% (n=13) con un promedio para las mediciones de
0.94 mm hacia anterior de la cúspide y 0.97 mm hacia posterior de ésta. La relación del
método BPS con respecto a la cúspide presentó un porcentaje de éxito de 27% (n=27)
con un promedio para las mediciones de 0.94 mm hacia anterior de la cúspide y 0.97
mm hacia posterior de ésta
Los resultados obtenidos en las relaciones de Schiffman y de Grove-Christensen
fueron similares a lo descrito en otros estudios, es por esto que es posible afirmar que
estas relaciones permiten adecuadamente la ubicación de la cúspide y punto de contacto
distal canino respectivamente con lo cual pueden ser una referencia, en el caso de
desdentados totales, al momento de posicionar los dientes en el maxilar superior. Las
relaciones establecidas para el método BPS no mostraron ser eficaces en la ubicación
exacta de la cúspide ni del punto de contacto distal canino, sin embargo otras relaciones
a través del eje central de la ruga palatina pueden ser halladas.
|
162 |
Análise de resistência mecânica em implantes de ossoBento, Daniela Águida January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2012-10-21T04:24:39Z (GMT). No. of bitstreams: 1
191947.pdf: 9398490 bytes, checksum: 267c0cabf73f2da4def32a7c1abe12dc (MD5) / Os implantes, utilizados atualmente em ortopedia e odontologia, apresentam inúmeros inconvenientes, dentre os quais se destaca a rejeição biológica que provoca a redução do desempenho biomecânico na região de tratamento. Uma alternativa para este problema seria a utilização de um material para estes implantes que atue como elemento estrutural durante o período de reparo e que seja posteriormente absorvido pelo organismo, evitando assim a necessidade de sua remoção. Esta é a proposta dos implantes fabricados em osso. Neste trabalho é investigado o comportamento biomecânico de parafusos de osso cortical bovino liofilizado, implantados na diáfise femoral de coelhos, através de análise experimental e numérica em três grupos de fêmures: com implante de osso, com implante de titânio e sem implante. Na análise experimental, estes fêmures foram submetidos ao ensaio mecânico destrutivo de flexão por quatro pontos. A simulação computacional destes ensaios foi realizada através de modelos de elementos finitos 3D para cada grupo, para a verificação das tensões e deformações induzidas nos implantes e região próxima a este, em função da condição de osseointegração. Os resultados obtidos demonstram que os implantes de osso cortical bovino liofilizado apresentam requisitos biomecânicos satisfatórios, entretanto, são necessárias pesquisas complementares, para poder validar a sua aplicação em tratamentos específicos.
|
163 |
Avaliação da osseointegração promovida por implantes jateados por Al2O3: análises histológica e histométrica em cãesPonzoni, Daniela [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T19:41:00Z : No. of bitstreams: 1
ponzoni_d_dr_araca.pdf: 781446 bytes, checksum: 6716157527edd6e5ca653e94715b65fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A formação de uma interface osseointegrada é mais previsível quando osso denso e saudável está em contato com a superfície do implante no momento da instalação. Porém, a colocação de implantes imediatos após exodontia apresenta inúmeras vantagens, entre elas a preservação da arquitetura óssea e gengival dos processos alveolares, além da diminuição do tempo cirúrgico. A utilização de uma superfície modificada proporciona um maior contato ósseo com o implante; baseado em princípios biológicos. A proposta deste trabalho é avaliar qualitativa e quantitativamente a interface entre osso e os implantes de titânio, jateados por Al2O3 instalados imediatamente após exodontias, em cães. Os implantes foram instalados nos alvéolos de pré-molares mandibulares bilateralmente em quatro cães. Foram instalados quatro implantes para cada animal (4mm de diâmetro e 10mm de comprimento) do Sistema Colosso (Emfils®), sendo dois de cada lado da mandíbula. Os animais foram sacrificados aos 120 dias pós-operatórios. As peças foram desmineralizadas, e os implantes removidos. Três implantes foram perdidos, três fibrointegrados e dez osseointegrados. A análise quantitativa foi realizada considerando-se cinco roscas apicais e o fundo do implante. A análise histológica mostrou tecido ósseo saudável em fase de maturação em íntimo contato com os implantes osseointegrados. Na análise histométrica, observou-se um contato ósseo de 76% nos implantes osseointegrados. / An osseointegrated interface could be predictable when dense and healthy bone is in contact with the titanium implant surface at the moment of implant insertion. However, immediate implantation after exodontia presents numerous advantages, among them, maintenance of bone and gingival architecture and decrease of operative time. The use of an implant with modified surface favors bone contact, according to biological principles. This study aims to evaluate the interface between bone and Al2O3 blasted titanium implants installed in 4 dogs immediately after bilateral exodontias of mandibular premolars. Four Emfils® implants (Sistema Colosso - 4mm diameter; 10mm length), 2 per side, were used in each dog. Animals were sacrificed after 120 days of surgery and the samples removed. Bone was decalcified and the implants removed. Three implants were lost, 3 had fibrointegration and 10 osseointegrated. Histological analysis showed a healthy tissue in process of maturation interfacing osseointegrated implants. Quantitative analysis was focused in 5 apical threads and the bottom of the implants. It was shown a contact of 76% between bone and the implants. Osseointegration was achieved around Al2O3 blasted titanium implants installed immediately after exodontias.
|
164 |
Estudio comparativo in vitro, de la resistencia flexural de materiales utilizados en la realización de provisionales para la ferulización rígida de implantes oseointegrados : acrílico v/s acrílico con refuerzo de metal coladoAvilés Nahuelpán, Felipe January 2008 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Autor no autoriza el acceso a texto completo de su documento / Se realizó un estudio comparativo in Vitro para evaluar la resistencia
flexural del acrílico reforzado con metal colado y la del acrílico sin refuerzo.
Dichas posibilidades son normalmente utilizadas como medio de ferulización
rígida de implantes oseointegrados con carga inmediata.
Se confeccionaron probetas, de acrílico de termopolimerización con y sin
refuerzo interno de metal colado Cr-Ni, las cuales fueron utilizadas para la
aplicación de la prueba de presión en tres puntos. Dichos instrumentos de
prueba fueron cargados mecánicamente hasta su fractura, siendo registrados
los valores de carga requeridos para cada uno.
Considerando las dimensiones y la fuerza necesaria para el quiebre de
cada probeta, se calculó su resistencia flexural. Los valores fueron analizados
estadísticamente de forma descriptiva y comparativa para la determinación de
diferencias significativas entre ambos grupos.
No se encontraron diferencias significativas de resistencia flexural entre
el acrílico reforzado con metal colado y el acrílico libre de refuerzo.
|
165 |
Estudo clínico prospectivo utilizando implantes curtos unitários posteriores / Prospective clinical trial using short implants in posterior single crowsSilveira Júnior, Clebio Domingues da 30 June 2011 (has links)
O objetivo deste estudo foi avaliar clínica e radiograficamente implantes curtos com 5 e 6 mm de comprimento (Titamax WS Neodent/ Curitiba-Brasil) unitários instalados em região posterior de mandíbula e maxila com pouca altura óssea. Foram instalados 10 implantes em 8 pacientes devidamente selecionados a partir de critérios de inclusão pré-determinados. Os mesmos receberam carregamento protético somente após o tempo convencional de espera para a osseointegração. Seis implantes foram instalados em mandíbula e 4 implantes em maxila. Tomadas radiográficas foram realizadas para avaliação das perdas ósseas verticais e horizontais nos tempos T0 (Instalação cirúrgica), T1 (Reabertura), T2 (Instalação protética) e T3 (Acompanhamento de 6 meses). Foram avaliados parâmetros biológicos como, sangramento gengival, índice de mucosa ceratinizada, índice de placa e índice de inflamação gengival. Também foram avaliados parâmetros protéticos como proporção coroa-implante e distância mesiodistal. Apenas um implante (Titamax WS Cortical 5.0x6.0) foi perdido ainda no período de osseointegração portanto o índice de sucesso foi de 90% no período avaliado. A alteração do nível ósseo foi analisada em três períodos diferentes, da instalação cirúrgica à cirurgia de reabertura (período 1), da reabertura à instalação protética (Período 2) e da instalação protética ao controle de seis meses (Período 3). Avaliando-se a perda óssea vertical nos três períodos separadamente foram encontrados valores muito semelhantes, inclusive iguais estatisticamente (ANOVA, p<0,05). O valor de perda óssea no período 1 foi de 0,32mm; no período 2 foi de 0,22mm e no período 3 foi de 0,29mm. Isso significa que os procedimentos cirúrgicos foram igualmente causadores de perda óssea marginal mesmo tomando-se alguns cuidados na execução destas etapas. A média de perda óssea vertical e horizontal no período total de acompanhamento foi de 0,87 ±0,46 e 0,24± 0,34 respectivamente. Estes valores foram considerados dentro do intervalo de perda óssea esperado. A boa condição de saúde gengival e higiene oral descartaram a possibilidade de associação entre os índices periodontais e a perda óssea periimplantar. O teste estatístico de Regressão Linear (p<0,05) mostrou não haver relação de causa/efeito entre perda óssea e os parâmetros protéticos, apesar de elevada proporção coroa/implantes (média 1,88). Com base nos resultados encontrados neste trabalho, concluiu-se que os implantes curtos, mesmo os de comprimento 5 e 6mm, devem ser considerados como uma importante alternativa de tratamento para casos unitários. Sugere-se porém, um maior tempo clínico de acompanhamento para que seja possível traçar um perfil do comportamento destes implantes a longo prazo. / The aim of this study was to evaluate clinically and radiographically short unit implants with 5 and 6 mm in length (Titamax WS - Neodent / Curitiba, Brazil) installed in the posterior mandible and maxilla with little bone height. Ten implants were installed in eight carefully selected patients from inclusion criteria pre-determined. They received prosthetic loading only after the conventional time waiting for the osseointegration. Six implants were placed in the mandible and four implants in the maxilla. Radiographs were performed to evaluate the vertical and horizontal bone loss in T0 (surgery installation), T1 (uncovering), T2 (prosthetic installation) and T3 (follow-up of 6 months). Biological parameters were evaluated such as gingival bleeding index, keratinized mucosa amount, plaque index and gingival inflammation index. Prosthetic parameters were also evaluated as crown-implant ratio and mesiodistal distance. Only one implant (Titamax WS Cortical 5.0x6.0) was lost, it occurred during the healing fase. Therefore the success rate was 90% in the period. Bone level change was analyzed in three different periods, from surgical installation to uncovering surgery (1st period), from uncovering to prosthetic installation (2nd Period) and from prosthetic installation prosthetic to six months control (3rd Period ). Vertical bone loss values were very similar when evaluated in the three periods separately, even the same statistically (ANOVA, p <0.05). The amount of bone loss in 1st period was 0.32 mm in the 2nd period was 0.22 mm and in the 3rd period was 0.29 mm. This means that surgical procedures were also cause marginal bone loss even taking some care in implementing these steps. The average vertical and horizontal bone loss in the total period of observation was 0.87 ± 0.46 and 0.24 ± 0.34 respectively. These values were considered within the range of bone loss expected. The gingival good condition of health and oral hygiene ruled out the possibility of an association between periodontal indices and bone loss. Statistical analysis of linear regression (p <0.05) showed no cause and effect relationship between bone loss and prosthetic parameters, despite the high crown / implant ratio (average 1.88). Based on the findings of this study, it was concluded that short implants, even the 5 and 6 mm in length, should be considered as an important alternative treatment for single crows. It is suggested a longer clinical follow-up to make it possible to trace a pattern of behavior of these implants over the long term.
|
166 |
"Análise da deformação gerada em infra-estruturas de prótese fixa implanto-suportada, através do uso de extensômetros".Janson, Vinicius dos Reis Pereira 13 May 2002 (has links)
O êxito clínico dos implantes osseointegrados é amplamente determinado, pela maneira como o estresse mecânico é transferido do implante, ao tecido ósseo circundante, sem gerar forças de grande magnitude, o que poderia colocar em risco a longevidade do próprio implante e da restauração protética. Inúmeros aprimoramentos técnicos, assim como desenhos e ligas metálicas alternativas para a confecção de infra-estruturas, têm sido propostos para melhorar os procedimentos protéticos. O objetivo deste trabalho foi verificar a distribuição de estresse em infra-estruturas de prótese fixa implanto -suportada, através do uso de extensômetros, em função de duas ligas metálicas. Corpos de prova simulando infra-estruturas para uma situação de prótese total fixa mandibular, foram confeccionados em liga de cobalto-cromo e paládio-prata e posicionados sobre um modelo-mestre. Uma carga estática vertical de 100N foi aplicada na extremidade livre, a uma distância de 10, 15 e 20mm para distal do centro do intermediário terminal. Os resultados demonstraram que em grandes extensões de cantilever, a liga de cobalto-cromo apresentou deformação semelhante à liga de paládio-prata com cantilever curto. O emprego de uma liga de cobalto -cromo na confecção de infra-estruturas para prótese sobre implantes pode permitir braços de cantilever mais extensos. / The clinical success of osseointegrated implants are largely influenced by the manner mechanical deformation are transferred from implant to surrounding bone, without generating forces of a magnitude that would jeopardize the longevity of implant and prosthesis. A variety of technical improvements, as well as alternative framework designs and alloys have been reported to improve prosthetic procedures. The aim of this study was to analyze the deformation on frameworks of a fixed implant-supported prosthesis, fabricated with two metal alloys. The samples simulated a typical mandibular fixed complete -arch framework and were fabricated on cobalt-chromium alloy and palladium-silver alloy and positioned on a master-cast. A vertical estatic load of 100N was applied on the cantilever arm at a distance of 10, 15 and 20mm from the center of distal abutment. Strain gauges were positioned on the distal aspect of last abutment to capture deformation. The results demonstrated that for large cantilever extensions, the cobalt-chromium alloy presented deformation similar to that observed for palladium-silver alloy with short cantilever. Using a cobalt-chromium alloy may allow longer cantilever arms.
|
167 |
Rediseño del sistema mecánico del exoesqueleto PUCP para rehabilitación de miembros inferioresDávila Portals, Diego 10 July 2018 (has links)
En este Proyecto de tesis se realizó el diseño de mejoras para el sistema mecánico del
Exoesqueleto PUCP para rehabilitación de miembros inferiores. El resultado ha sido
planos de fabricación y de ensamble que se basan en el método de diseño en ingeniería
de acuerdo a la norma VDI 2221, así como una estimación de costos para la realización
de estas mejoras. El costo de realización de este Proyecto es de aproximadamente S/.
72,600.00, lo cual incluye el costo de fabricación de los componentes (aprox. S/.
54,600.00), el costo de los componentes comerciales que se necesitarían comprar
(aprox. S/. 3,000.00), los costos de logística y montaje, así como el costo de diseño (S/.
15,000.00).
El diseño se realizó tomando como punto de partida las necesidades de los pacientes
que requieren de terapias para la rehabilitación de la marcha, así como las exigencias
mecánicas que se deben cumplir para el funcionamiento del Exoesqueleto. La
metodología seguida fue, descrita a grandes rasgos: se revisaron los fundamentos para
la rehabilitación de la marcha humana y las tecnologías existentes para apoyarla, luego
se evaluaron los problemas y limitaciones que presenta el sistema mecánico del
Exoesqueleto PUCP, para así elaborar las principales propuestas de mejora, y
finalmente, se realizaron los cálculos de ingeniería y los planos correspondientes, así
como una estimación del costo de implementación.
En el capítulo 3 de este Proyecto se exponen los cálculos realizados para la ingeniería
de detalle. Se realizaron análisis de cargas, así como análisis de esfuerzos en las
secciones críticas de los elementos y verificación de rigidez por deflexión. Las fuentes
de las teorías utilizadas para el análisis están referenciadas a lo largo de este capítulo.
En base a las piezas diseñadas se realizó también una estimación de costos de este
Proyecto.
Finalmente se hizo una auto evaluación del trabajo realizado de modo que se pudieran
identificar mejoras que no se pudieron abordar en este Proyecto y limitantes generadas
por los alcances del mismo. También se evaluaron los resultados obtenidos durante la
realización del Proyecto y su impacto en el contexto actual. / Tesis
|
168 |
Diseño de un prototipo de mecanismo de exoesqueleto posicionador de espalda para entrenamiento deportivo de tiro con arcoMamani Aliaga, Kendy Elvis 23 January 2018 (has links)
La presente tesis consiste en el diseño del prototipo del mecanismo de un
exoesqueleto posicionador de espalda enfocado en contribuir con el entrenamiento
deportivo del tiro con arco. Un exoesqueleto es un implemento mecánico, accionado
generalmente por actuadores electrónicos o neumáticos, el cual es portado por una
persona a fin de guiar su movimiento y a su vez mejorar habilidades físicas como la
fuerza o motrices como la precisión del usuario. Respecto a esto se vienen realizando
estudios que indican que estos mecanismos también permiten a personas con
problemas o lesiones motoras acelerar la recuperación de sus habilidades motrices,
por ello estos mecanismos vienen demostrando su eficacia en terapias de
rehabilitación. El principio de las terapias de rehabilitación consiste en la repetición
continua de determinados movimientos en el miembro afectado y precisamente estos
mecanismos pueden programarse a fin de repetir infinidad de veces estos
movimientos con una gran precisión. Por otro lado en el caso de personas sin
problemas motores se ha demostrado que estos mecanismos contribuyen con
acelerar el aprendizaje de movimientos nuevos y a su vez contribuir con la mejora de
habilidades motrices como la precisión del movimiento. Igual que en el caso anterior
esto se logra mediante la repetición continua del movimiento nuevo que se quiere
aprender o mejorar.
El tiro con arco es un deporte con gran potencial de masificación en el país, se puede
practicar a cualquier edad y no requiere un biotipo en especial. Si bien esta disciplina
requiere pocos movimientos durante su ejecución deben realizarse con gran
precisión. Habilidad que puede desarrollarse con el uso de un exoesqueleto.
Para el diseño del mecanismo se tuvieron que realizar visitas a centros deportivos de
tiro con arco a fin de reconocer los movimientos característicos para dirigir el
movimiento de la flecha. Se pudo reconocer que al mantener los brazos tensados al
apuntar era la espalda la que permitía controlar la dirección final de la flecha.
Posteriormente se realizó un modelo matemático para obtener los parámetros
inerciales de un individuo con las medidas del peruano promedio. Se planteó un
diseño preliminar, se reconoció la distribución de cargas sobre el mecanismo y se
realizó la ingeniería de detalles para finalmente obtener los planos de fabricación del
mecanismo propuesto / Tesis
|
169 |
Synthesis of Hydroxyapatite thin films on PMMA Printed SubstratesSauñi Camposano, Yesenia Haydee 19 January 2018 (has links)
Each year millions of people suffer from bone defects resulting from trauma, tumors or
bone-related injuries. Therefore there is a need to continuously develop new materials or
improve the properties of the materials currently used, for bone replacement or implant
applications. Polymethyl methacrylate (PMMA) has proven to be a promising alternative
as a material for implants; however, there are still some limitations inherent to this
material, particularly related to its surface properties.
This thesis work is focused on the fabrication of hydroxyapatite (HAp) thin films on the
surface of 3D printed PMMA substrates. 3D printing, particularly the Fused Deposition
Modeling (FDM) technique was used to fabricate PMMA substrates with different surface
porosity levels. FDM technique exhibits the potential for fabricating customized freeform
structures for several applications including craniofacial reconstruction. HAp thin films
were deposited by Radio Frequency Magnetron Sputtering (RFMS) and Ion Beam
Sputtering (IBS) techniques, with a commercial target and an “in house” sintered target,
respectively. A structural, chemical, mechanical, and morphological characterization was
conducted in the generated surfaces by means of X-ray diffraction (XRD), scanning
electron microscopy (SEM), energy dispersive spectroscopy (EDS), and hardness and
roughness measurements.
The results of the XRD analysis revealed an amorphous structure for the films produced by
both RFMS and IBS techniques on the PMMA substrates. The micrographs obtained by
SEM showed a columnar morphology and a low density for the films produced by RFMS;
the same technique revealed a structure of ridges of standing platelets with curved
contours for the IBS deposited films. The amorphous structure and the morphology of the
films, as well as the hardness and roughness can be propitious to improve surface
properties and promote the osseointegration capabilities of PMMA.
This work contributes to the basis for the development of a PMMA implant manufacturing
process using 3D printing and HAp film deposition techniques, with improved
osseointegration properties. / Cada año, millones de personas sufren defectos óseos como resultado de traumas, tumores
o lesiones relacionadas con los huesos. Por lo tanto, existe la necesidad de desarrollar
continuamente nuevos materiales o mejorar las propiedades de los materiales utilizados
actualmente, para aplicaciones de reemplazo óseo o implantes. El polimetilmetacrilato
(PMMA) ha demostrado ser una alternativa prometedora como material para implantes;
sin embargo, todavía existen algunas limitaciones inherentes a este material,
particularmente relacionadas con sus propiedades superficiales.
Este trabajo de tesis se centra en la fabricación de películas delgadas de hidroxiapatita
(HAp) en la superficie de sustratos de PMMA impresos en 3D. La impresión 3D,
particularmente la técnica de modelado de deposición fundida (FDM), se utilizó para
fabricar sustratos de PMMA con diferentes niveles de porosidad superficial. La técnica
FDM exhibe el potencial para fabricar estructuras personalizadas de para varias
aplicaciones, incluida la reconstrucción craneofacial. Las películas delgadas de HAp se
depositaron mediante técnicas de deposición catódica con Magnetrón y radio frecuencia
(RFMS) y deposición catódica con haz de iones (IBS), con un target comercial y un target
sinterizado "in house", respectivamente. Se realizó una caracterización estructural,
química, mecánica y morfológica en las superficies generadas por medio de difracción de
rayos X (XRD), microscopía electrónica de barrido (SEM), espectroscopía de energía
dispersiva (EDS) y medidas de dureza y rugosidad.
Los resultados del análisis de XRD revelaron una estructura amorfa para las películas
producidas por ambas técnicas RFMS e IBS en los sustratos de PMMA. Las micrografías
obtenidas por SEM mostraron una morfología columnar y una baja densidad para las
películas producidas por RFMS; la misma técnica reveló una estructura de crestas de
plaquetas con contornos curvados para las películas depositadas IBS. La estructura amorfa
y la morfología de las películas, así como la dureza y la rugosidad pueden ser propicias
para mejorar las propiedades de la superficie y promover las capacidades de
oseointegración del PMMA.
Este trabajo contribuye a la base para el desarrollo de un proceso de fabricación de
implantes de PMMA usando impresión 3D y técnicas de deposición de película HAp, con
propiedades mejoradas de oseointegración. / Tesis
|
170 |
Modelado y optimización de una placa (implante) para sujeción de injerto en la columna vertebral por el método de los elementos finitosÁlvarez Sánchez, Helard Henry 09 May 2011 (has links)
El objetivo del trabajo es analizar la placa (implante) a través de un modelo capaz de proporcionar valores de tensiones y desplazamientos bajo las diferentes condiciones de carga en distintos puntos de la placa que pueden son necesarios conocer. Esta información es de gran importancia, porque una cirugía persigue que la prótesis hueso del sistema este bajo un estado mecánico íntimo al hueso, promueve una estabilidad más grande y durabilidad de la placa y reduce el número de cirugías necesarias durante la vida del paciente. / Tesis
|