• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1383
  • 113
  • 47
  • 44
  • 44
  • 43
  • 26
  • 16
  • 13
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 1556
  • 886
  • 745
  • 656
  • 292
  • 235
  • 207
  • 162
  • 156
  • 140
  • 139
  • 138
  • 137
  • 136
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Biocompatilibidade in vivo de implantes de titânio submetidos ao processo biomimético

Machado, Ana Cristina Posch [UNESP] 13 February 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-02-13Bitstream added on 2014-06-13T19:01:08Z : No. of bitstreams: 1 machado_acp_dr_sjc.pdf: 3944406 bytes, checksum: 12231bfae0b05fe47117cdc9fa22d4f3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Propõe-se neste estudo avaliar a neoformação óssea no interior dos poros e ao redor de implantes porosos de titânio, submetidos ao processo biomimético modificado, inseridos em tíbias de coelhos. Foram confeccionados 180 implantes de titânio puro grau 2, com porosidade controlada, obtidos por meio da metalurgia do pó. Noventa implantes foram pré-tratados com solução de NaOH à 130ºC/1h, submetidos à temperatura de 200ºC/1h e posteriormente imersos em fluido corpóreo simulado modificado por 14 dias. Os implantes foram inseridos em 30 coelhos sendo que cada um recebeu 3 implantes tratados na tíbia esquerda e 3 sem tratamento na tíbia direita. Os animais foram sacrificados em 15, 30 e 45 dias após a cirurgia e os fragmentos das tíbias contendo os implantes foram submetidos à análise histológica, histomorfométrica e teste mecânico de cisalhamento. A análise microestrutural das amostras foi realizada por microscopia eletrônica de varredura (MEV), espectrometria por energia dispersiva de raios X (EDS) e espectroscopia Raman e a avaliação da neoformação óssea por microscopia de luz (MO) e MEV, comparando implantes sem tratamento com aqueles submetidos ao tratamento biomimético. O EDS indicou que a superfície do implante após o tratamento biomimético continha principalmente cálcio (Ca) e fósforo (P) além da presença de titânio. A Espectroscopia Raman do implante de titânio, após o tratamento biomimético, indicou pico característico e de grande magnitude a 960cm-1 devido à formação de uma camada de hidroxiapatita. As imagens ao MO e MEV demonstraram que houve neoformação óssea na interface osso-implante e no interior dos poros, inclusive naqueles mais centrais. Observou–se que a porcentagem média de neoformação óssea nos implantes tratados nos três tempos de sacrifício foi maior do que nos implantes não tratados, sendo observada diferença... / The purpose of this study is to define the coating on porous titanium implants submitted to modified biomimetic process and to evaluate bone neoformation inside the porous and around these implants when inserted in tibiae of rabbits. One hundred and eighty pure titanium implants, fabricated by powder metallurgy, were made. Ninety implants were pretreated with NaOH solution at 130ºC/1h and submitted to the temperature of 200ºC/1h and immersed in modified simulated body fluid for 14 days. The implants were inserted in 30 rabbits; each rabbit received 3 treated implants in the left tibia and 3 untreated implants in the right tibia. The animals were sacrificed after 15, 30, and 45 days of surgery and the tibia fragments containing the implants were submitted to histological and histomorphometric analyses and shear strength test. The microstructure analysis of the samples was performed by scanning electron microscope (SEM), energy dispersive spectrometry (EDS) and Raman spectroscopy; the bone neoformation was evaluated by light microscopy (MO) and SEM comparing only sinterized implants with those submitted to biomimetic treatment. The EDS indicated that the implant surface after biomimetic treatment contained mainly calcium (Ca) and phosphorous (P) in addition to the presence of titanium. The Raman spectroscopy of the titanium implant, after biomimetic treatment, indicated the formation of a hydroxyapatite layer due to the characteristic peak and of great magnitude at 960cm-1. The MO and SEM images showed bone neoformation on the interface bone-implant and inside the porous, including the most internal ones. It was observed that the mean percentage of bone neoformation in the treated implants for the three sacrifice periods were higher than the untreated implants, statistically significant for the 15-day period. The mechanical test showed that the coated implants... (Complete abstract, click electronic access below)
182

Comparação das avaliações histológica, clínica e por meio de exames de imagens da qualidade óssea da região maxilomandibular para a instalação de implantes dentários / Comparison of histological, clinical and imaging evaluations of the bone quality of different maxillomandibular regions for placement of dental implants

Oliveira, Marina Reis [UNESP] 14 March 2017 (has links)
Submitted by Marina Reis Oliveira (marinareis89@hotmail.com) on 2017-03-27T11:56:30Z No. of bitstreams: 1 Tese Doutorado - Marina Reis Oliveira.pdf: 3425386 bytes, checksum: ec09aa76b0be923cb1b87f76fc5aee71 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-03-29T18:49:21Z (GMT) No. of bitstreams: 1 oliveira_mr_dr_arafo.pdf: 3425386 bytes, checksum: ec09aa76b0be923cb1b87f76fc5aee71 (MD5) / Made available in DSpace on 2017-03-29T18:49:21Z (GMT). No. of bitstreams: 1 oliveira_mr_dr_arafo.pdf: 3425386 bytes, checksum: ec09aa76b0be923cb1b87f76fc5aee71 (MD5) Previous issue date: 2017-03-14 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O presente trabalho teve como objetivo avaliar a qualidade óssea das diferentes regiões alveolares da maxila e da mandíbula por meio da classificação óssea proposta por Leckholm e Zarb (1985) (L & Z), radiografias panorâmicas e periapicais, quociente de estabilidade do implante (ISQ), torque de inserção (TI), microtomografia computadorizada (micro-CT) e histomorfometria. Como objetivo secundário, foi avaliada a correlação entre os diversos métodos citados acima. Foram avaliadas 60 áreas edêntulas, sendo 15 áreas de cada quadrante da maxila e da mandíbula. A qualidade óssea tipo III foi a mais frequente na maxila posterior (73,33%) e anterior (73,33%), já a tipo II foi mais frequente na mandíbula posterior (53,33%) e anterior (60,00%). Foi observada uma diferença estatisticamente significante na densidade óssea óptica avaliada por meio de radiografias periapicais na região posterior da maxila (2,38±1,06) e posterior da mandíbula (3,84±0,68), em relação às demais regiões alveolares avaliadas (p≤0,015). Nas radiografias panorâmicas não foram observadas diferenças entre a densidade óptica das regiões alveolares (p=0,6322). A estabilidade inicial dos implantes instalados na região posterior da maxila foi estatisticamente diferente dos instalados na região posterior da mandíbula, tanto na avaliação por meio do TI como por meio do ISQ (p<0,05). Também foi possível detectar diferenças na qualidade óssea das regiões alveolares da maxila e da mandíbula por meio de vários parâmetros da micro-CT (BV, p≤0,002; BV/BT, p≤0,044; BS, p<0,027; BS/BV, p<0,05; BS/TV, p<0,05; Tb.N, p<0,01 e Tb.Sp, p<0,05). Por meio da histometria foi verificada diferença estatística na quantidade de tecido ósseo da região posterior da maxila em relação a região anterior e posterior da mandíbula (p≤0,043). Entretanto, não houve diferenças na contagem de osteócitos entre as regiões alveolares (p=0,2946). Quanto à análise de correlação, a densidade óssea óptica avaliada por meio das radiografias periapicais correlacionou-se com o TI, com o ISQ e com vários parâmetros da micro-CT (BV, BV/BT, Tb.Th, Tb.N, BS/BV, Tb.Pf e ISM) (rho≤0,471; p≤0,028). Entretanto, a radiografia panorâmica apresentou apenas correlação com a BS e a BS/TV (rho≤0,290; p≤0,031). O TI apresentou correlação com o ISQ, histometria e vários parâmetros da micro-CT (BV, BS/TV, Tb.Th, Tb.N, BS/BV, Tb.Pf, Tb.Sp, BV/BT) (rho≤0,550; p≤0,022). Em contrapartida, o ISQ não apresentou correlação com nenhum parâmetro da micro-CT. A classificação de L & Z mostrou correlação com a densidade óptica avaliada por meio das radiografias periapicais, histometria, contagem de osteócitos, TI e vários parâmetros da micro-CT (BS/BV, Tb.Sp, Tb.Pf, BV, BS/TV, Tb.Th, Tb.N) (rho≤0,344; p≤0,042). Esses resultados sugerem que a classificação óssea de L & Z e o TI podem ser considerados métodos confiáveis na avaliação da qualidade óssea. As radiografias periapicais são um método aceitável na avaliação da qualidade óssea. A radiografia panorâmica, por sua vez, não se mostrou um método confiável para a avaliação da qualidade óssea. / This study aimed to evaluate the bone quality of the different alveolar regions of the maxilla and mandible through of the classification proposed by Leckholm e Zarb (1985) (L & Z), panoramic and periapical radiographs, implant stability quotient (ISQ), insertion torque (IT), microcomputed tomography (micro-CT) and histomorphometric analysis. The secondary objective was to evaluate the correlation between the several methods mentioned above. Sixty edentulous areas were evaluated, being 15 areas from each quadrant of the maxilla and mandible. The bone quality III was the most frequent in the posterior (73.33%) and anterior maxilla (73.33%) and quality II was the most frequent in the posterior (53.33%) and anterior (60.00%) mandible. A significant statistical difference was observed in the optical bone density evaluated through periapical radiographs of the posterior maxilla (2.38 ± 1.06) and posterior mandible (3.84 ± 0.68), in relation to the other alveolar regions (p≤0.015). With the panoramic radiograph no differences were observed between the optical density of the alveolar regions (p= 0.6322). The primary stability of the implants in the posterior maxilla was different from the posterior mandible, both in the evaluation through the TI and ISQ (p<0.05). It was possible to detect differences in the bone quality of the alveolar regions using several micro-CT parameters (BV, p≤0.002; BV/BT, p≤0.044; BS/TV, p <0.05; Tb.N, p<0.01 and Tb.Sp, p <0.05). With the histometry it was possible to detect difference in the amount of bone of the posterior maxilla in relation to the anterior and posterior mandible (p≤0,043). However, there were no differences in osteocyte counts between the alveolar regions (p=0.2946). Concerning the correlation analysis, the optical bone density evaluated by the periapical radiographs correlated with the TI, ISQ and various parameters of the micro-CT (BV, BV/BT, Tb.Th, Tb.N, BS/BV, Tb.Pf and ISM) (rho≤0.471, p≤0.028). In contrast, the ISQ did not correlate with any of the micro-CT parameters. The L & Z classification showed correlation with the optical density evaluated by periapical radiographs, histometry, osteocyte count, TI and several microCT parameters (BS/BV, Tb.Sp, Tb.Pf, BV, BS/TV, Tb.Th, Tb.N) (rho≤0.344; p≤0.042). Those results suggest that the L & Z bone classification and TI can be considered reliable methods for evaluating bone quality. Periapical radiographs are an acceptable method for assessing bone quality. The panoramic radiograph, on the other hand, is not a reliable method for evaluating bone quality. / FAPESP: 2014/25253-1
183

Avaliação da injeção de polietileno gel no subcutâneo de ratos /

Bernardes, Suely Romano. January 2002 (has links)
Orientador: Silvana Artioli Schellini / Resumo: Esta pesquisa foi realizada com o objetivo de se avaliar o comportamento do polietileno gel como um material para ser usado para a reposição de volume ou aumento de tecidos moles e para se estudar as reações teciduais que se seguem à sua injeção no subcutâneo dorsal de ratos. Material e método: uma injeção de 01 cc de polietileno gel (Makron Biopolímeros Ltda. - Mogi das Cruzes - SP - Brasil) foi efetuada na região subcutânea dorsal de 24 ratos brancos, machos, pesando cerca de 200 gramas cada um, sob anestesia geral, tricotomia e assepsia. Os animais foram separados em oito grupos e foram sacrificados 7 (G1), 15 (G2), 30 (G3), 45 (G4), 60 (G5), 90 (G6), 180 (G7) e 365 (G8) dias após a injeção da substância a ser estudada. Os espécimes foram removidos e preparados para o exame histopatológico. Este foi realizado ao microscópio óptico e foi realizada também a análise morfométrica dos dados obtidos. Os resultados foram submetidos à análise estatística (Kruskal-Wallis). Resultados: a comparação entre os grupos revelou que o polietileno gel esteve presente através de todo o período experimental, provocando escassa reação tecidual, com poucas células inflamatórias, principalmente na periferia do material e no começo do experimento. Posteriormente, essa reação foi mais densa, avançando para o centro do material e também com poucas células inflamatórias. Nenhum sinal de infecção foi observado durante o período experimental. Conclusões: a manutenção do PG, com reação inflamatória muito discreta e sem sinais de rejeição ou infecção, leva-nos a considerar este material como sendo uma boa opção para reposição de volume e para aumento de tecidos moles. / Abstract: This research was performed in order to evaluate the effects of gel polyethylene as a material to be used for reposition of lack of volume or soft-tissue augmentation and to study the tissue reactions following the injection of this substance into the dorsum subcutaneous region of rats. Material and methods: an injection of 1 cc of gel polyethylene (Makron Biopolímeros Ltda.- Mogi das Cruzes - SP - Brasil) was performed into the dorsal subcutaneous region of 24 white male rats, weighting about 200 grams each one, under general anesthesia, skin shaving and asepsis. The animals were separated into eight groups and they were sacrificed 7 (G1), 15 (G2), 30 (G3), 45 (G4), 60 (G5), 90 (G6), 180 (G7) and 365 (G8) days after the injection of the substance to be studied. The specimens were removed and they were prepared for the histopatologic examination, under optical microscopy. It was also performed the morphometric analysis of the observed data. The results were submitted to the statistic analysis (Kruskal-Wallis). Results: the comparison among the groups revealed that the maintenance of the presence of the gel polyethylene occurs throughout the experimental period, provoking a slack tissue reaction, with few inflammatory cells, mainly at the beginning of the experience. Later, the tissue reaction became denser, advancing to the center of the material, with also few inflammatory cells. The integration with the host was progressive and no sign of infection was observed throughout the experimental period. Conclusions: the injected gel polyethylene was present throughout the complete study, provoking a very slight inflammatory reaction and with a good integration with the host, taking us to consider that material as a good option for soft-tissue augmentation and lack of volume replacement. / Mestre
184

Usinabilidade e integridade superficial de implantes dentários /

Manera, Rodolfo da Silva. January 2014 (has links)
Orientador: Alessandro Roger Rodrigues / Banca: Hidekasu Matsumoto / Banca: Marcos Valerio Ribeiro / Resumo: Ligas metálicas destinadas a implantes, de um modo geral, têm sido cada vez mais pesquisadas quanto às suas propriedades mecânicas, microestruturais e características de biocompatibilidade. Apesar do surgimento de inúmeros materiais poliméricos, o titânio e suas ligas representam ainda a grande gama de aplicações na área da implantodontia. O titânio é considerado um material de difícil usinabilidade, pois desenvolve altas tensões e temperaturas em uma área de corte 2/3 menor que a de outros materiais. Assim, os parâmetros de usinagem e a ferramenta de corte necessitam ser adequadamente especificados, pois tanto a matéria-prima quanto o processo de fabricação levam a um alto valor agregado do produto final. Este trabalho determinou os efeitos da velocidade de corte e da profundidade de usinagem na usinabilidade (força de corte e energia específica de corte) e integridade superficial (microdureza e acabamento) no roscamento de implantes dentários de titânio comercialmente puro (grau 4, ASTM F67). Os ensaios foram realizados em torno CNC de cabeçote móvel, empregando ferramenta de metal duro revestida de TiAlN e fluido de corte abundante. Com base na Análise de Variância (ANOVA), os resultados mostraram que os parâmetros de corte afetam a usinabilidade e a integridade superficial da rosca, sendo a profundidade de usinagem o fator mais influente. Níveis muito baixos ou altos da profundidade de usinagem elevam a energia específica e a força de corte, respectivamente, encruando a subsuperfície da rosca e prejudicando a rugosidade dos flancos dos filetes. Velocidades de corte menores tendem a aumentar a força e a energia específica de corte, prejudicando o acabamento da rosca, mas não influem em sua dureza. Rugosidades estatísticas "Skewness" e "Kurtosis" apontaram a prevalência de picos agudos na superfície da rosca, favorecendo a osseointegração. Testes na condição High-Speed Cutting (HSC) indicaram ... / Abstract: Metallic alloys applied to implants have been researched aiming at improving their mechanical properties, microstructure and biocompatibility. Despite appearing several types of polymers in the last years, titanium and its alloys are still used extensively in the implantology. Titanium is considered a hard-to-cut material, because it develops high stresses and temperatures in a small cutting area (2/3 smaller than for other materials). Thus cutting parameters and tools need to be specified properly, since both raw material and manufacturing process increase the costs of the final product. This research determined the effects of cutting speed and depth of cut on machinability (cutting force and specific cutting energy) and surface integrity (microhardness and roughness) when threading pure commercially dental implants (grade 4, ASTM F67). Machining tests were carried out in a CNC lathe by applying TiAlN coated carbides and cutting fluid. Based on Analysis of Variance (ANOVA), the main results indicated that cutting parameters influence on machinability and surface integrity of the implant screw, being depth of cut the more influent. Low and high levels of depth of cut increase specific cutting energy and cutting force, respectively, hardening the screw subsurface and damaging the roughness of the thread flanks. Lower cutting speeds trend to raise both cutting force and specific cutting energy, damaging the screw finishing, but they do not affect its subsurface microhardness. Skewness and Kurtosis roughness parameters indicated the predominance of spiky surface on screw which is favorable to osseointegration. Tests at High-Speed Cutting (HSC) showed it is possible to machine implant screws, but depth of cut cannot be high so that avoiding vibration in threads / Mestre
185

Retorque de parafusos de pilares protéticos com recobrimento de carbono tipo diamante: uma análise da manutenção do torque após fadiga mecânica /

Canavezi, Rafaela Cristiane. January 2015 (has links)
Orientador: Lafayette Nogueira Júnior / Banca: Tarcísio José Arruda de Paes Junior / Banca: Argemiro Soares da Silva Sobrinho / Resumo: Esta pesquisa se propôs verificar a manutenção do torque, após fadiga mecânica, de parafusos de pilares protéticos com recobrimento de carbono tipo diamante (DLC) e com dopagem de diamantes (CD-DLC) submetidos ao retorque, em conexões hexagonais externa (HE) e interna (HI). Implantes HE e HI e diferentes tratamentos do parafuso protético foram alocados em grupos experimentais (n = 5): sem tratamento e não submetidos a fadiga (HE-CON) (HI-CON); sem tratamento fadigados (HECONF) (HI-CONF); com DLC fadigado (HE-DLCF) (HI-DLCF) e com CDDLC fadigados (HE-CD-DLCF) (HI-CD-DLCF). Os recobrimentos de DLC e CD-DLC foram depositados a plasma pelo método PECVD. As amostras (implante + parafusos + coroa metálica), que já haviam sido expostas a 1 milhão de ciclos de fadiga, foram retorqueadas com torquímetro digital, com o torque recomendado pelo fabricante 30 N (HE) e 20 N (HI), e submetidos novamente a 1 milhão de ciclos mecânicos. Ao término da fadiga, os parafusos foram destorqueados para verificar a manutenção do torque. Parafusos de cada grupo experimental foram selecionados para observação em MEV. A análise estatística foi realizada pelo teste Anova 2- Fatores (α = 0,05). Não houve interação entre os fatores em estudo (p = 0,765); o tratamento dos parafusos (p = 0,638) e o tipo de conexão (p = 0,615) não apresentaram diferença estatística. Alterações como danos nas roscas do parafuso e remoção do filme foram observados entre os grupos experimentais. Os grupos com revestimento apresentaram pouco ou nenhum dano nas roscas dos parafusos. O revestimento de DLC e CDDLC parece não ter interferido na adaptação do parafuso ao implante. Parafusos protéticos recobertos com DLC e CD-DLC, após o retorque, não elevaram a manutenção do torque / Abstract: The study analyzed the torque maintain of the screw abutments, with coating of diamond-like carbon (DLC) and doping of diamond (CD-DLC), submitted the retorque in external hexagonal (EH) and internal (IH) connections; after mechanical fatigue. HE and HI implants and different treatments of the abutments screws were divided into experimental groups (n = 5): untreated and not subjected to fatigue (EH-CON) (IHICON); fatigued untreatment (EH-CONF) (IH-CONF); fatigued with DLC (EH- DLCF) (IH-DLCF) and fatigued with CD-DLC (EH-CD-DLCF) (IH-CD-DLCF). The DLC and CD-DLC coating was deposited by plasma, PECVD method. Samples (Implant + abutment screew + metal crown), which had been exposed to 1 million fatigue cycles were retorquiadas, digital torque wrench, to the torque recommended by the manufacturer 30 N (HE) and 20 N (HI), and submitted again to 1 million cycles mechanics. At the end of fatigue, the screws were destorquiados to check the maintenance of torque. Screws from each experimental group were selected for observation by SEM. Statistical analysis was performed by ANOVA 2 Factors test (α = 0.05). There was no interaction among the factors studied (p = 0.765); the treatment of screws (p = 0.638) and the connection type (p = 0.615) showed no statistical difference. The microscopy images showed damage the threads and covering the presence of HI connections. Changes such as damage on the screws threads and film removal were observed among the experimental groups. The coating groups showed little or no damage on the screws threads. The DLC and CD-DLC coating did not interfere in the screw adaptation on the implant. Abutments screew coating with DLC and CD-DLC, after retorque, no raised torque maintenance / Mestre
186

Coating of polyethylene medical devices

Silva, Marta Alves da January 2008 (has links)
Tese de mestrado. Engenharia Biomédica. Faculdade de Engenharia. Universidade do Porto, Faculdade de Medicina Dentária. Universidade do Porto. 2008
187

Desenvolvimento de um dispositivo para avaliação dimensional de um processo de fabrico de implantes dentários

Carvalho, João Diogo Cardoso de January 2013 (has links)
Trabalho realizado na empresa BringConcept, orientado pelo Prof. Dr. Casimiro de Andrade / Tese de Mestrado Integrado. Engenharia Metalúrgica e de Materiais. Faculdade de Engenharia. Universidade do Porto. 2013
188

Adesão bacteriana e formação de biofilme em materiais para implantes dentários /

Avila, Erica Dorigatti de. January 2015 (has links)
Orientador: Francisco de Assis Mollo Junior / Co-orientador: Carlos Eduardo Vergani / Banca: Ana Claudia Pavarina / Banca: Gelson Luis Adabo / Banca: Cassio do Nascimento / Resumo: O sucesso clínico da terapia com implantes depende da osseointegração primária e da ausência de inflamação no tecido peri-implantar. Um importante fator contribuinte para o desenvolvimento da inflamação é a colonização de microrganismos e subsequente formação de biofilme tanto nos materiais para implante quanto para componentes protéticos. Neste estudo, nós focamos no efeito de um tratamento de superfície para implante de titânio (Ti) e em materiais para abutments na adesão de bactérias e formação de biofilme. O tratamento em questão, consiste na conversão das propriedades hidrofóbicas do Ti para hidrofílicas por meio da foto funcionalização da luz UV. Biofilme foi desenvolvido pela incubação dos discos com e sem tratamento, em rico meio de cultura contendo uma complexa comunidade oral representativa da saliva humana. A biomassa e o perfil das bactérias aderidas em ambas as superfícies foram analisadas após 3 e 16 horas. Para os demais experimentos, foram utilizados discos de Ti e zircônia (ZrO2) simulando as superfícies dos abutments de implantes e esmalte bovino (EB) como controle positivo. Biofilmes simples, com Streptococcus mutans (S. mutans), Porphyromonas gingivalis (P. gingivalis) e Fusobacterium nucleatum (F. nucleatum), e em multiespécie (P. gingivalis e F. nucleatum) foram desenvolvidos sobre as amostras e os resultados foram analisados quantitativamente e qualitativamente. O perfil das bactérias, também, foi analisado por meio do método de eletroforese em gel com gradiente desnaturante (DGGE). Em relação ao primeiro trabalho, embora o perfil das bactérias aderidas apresentou similaridade após 16 horas de incubação, a biomassa do biofilme formado sobre as superfícies de Ti tratado com a luz UV, foi significativamente menor. Ti e ZrO2 apresentaram fortes características hidrofóbicas enquanto o EB... ((Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Dental implant rehabilitation has become a routine procedure to replace missing teeth. Its success depends on proper osseointegration, as well as the lack of inflammation. An important factor contributing to the development of inflammation is the attachment of microorganisms and subsequent development of biofilms on the prosthetic components. This study focused on effect of materials and treatment surfaces on the bacterial adhesion and biofilm formation. We, first, assessed the biofilm formation on machined titanium (Ti) discs treated and untreated with UV photofunctionalization. UV-treatment was performed using a photo-device for 12 minutes. Hydrophobic-to-hydrophilic conversion was confirmed on UV-treated titanium surfaces. Biofilm was formed by incubating the discs in rich medium containing a complex representative saliva-derived oral microbial community. After 3 and 16 hours, the biomass of biofilm and the bacteria profile was analyzed. For other experiments, it was used titanium and zirconia (ZrO2) discs as abutment implants and bovine enamel (BE) as a positive control. Roughness means that topography and energy-free surface analysis were performed prior to applying microbiology biofilms onto materials. Biofilms in single species with Streptococcus mutans (S. mutans), Porphyromonas gingivalis (P. gingivalis) and Fusobacterium nucleatum (F. nucleatum) and multi species with P. gingivalis and F. nucleatum were developed on each samples and quantitatively evaluated by counting forming units (CFU) and qualitatively by confocal microscopy. Also, we analyzed the development of a complex oral biofilm on two different abutments implants surfaces. Quantitatively and qualitatively analysis were performed after 16 and 48 hours of incubation under anaerobic conditions. In relation to first study, the biomass of biofilm formed on UV treated surfaces was significantly... (Complete abstract electronic access below)
189

Efeito do recobrimento de filmes de carbono tipo diamante depositados a plasma na manutenção do torque de parafusos protéticos /

Lepesqueur, Laura Soares Souto. January 2014 (has links)
Orientador: Lafayette Nogueira Júnior / Co-orientador: Marcos Massi / Banca: Tarcisio José de Arruda Paes Junior / Banca: Luís Guilherme Scavone de Macedo / Resumo: Objetivo: Avaliar os valores de torque reverso RT(%) de parafusos protéticos de liga de titânio recobertos com um filme de carbono amorfo tipo diamante (DLC) e filme dopado com partículas de diamante(CD-DLC) comparando-os com parafusos sem tratamento (controle). Método: Foram utilizados 60 implantes de plataforma regular, divididos de acordo com o tipo de conexão (hexágono externo e hexágono interno) e o tratamento do parafuso protético (n=10): Grupo A1: hexágono externo/parafuso controle; Grupo A2: hexágono externo/parafuso com DLC; Grupo A3: hexágono externo/parafuso com CD-DLC; Grupo B1: hexágono interno/parafuso controle; Grupo B2: hexágono interno/parafuso com DLC; Grupo B3: hexágono interno/parafuso com CD-DLC. Os filmes de DLC e CD-DLC foram depositados pelo processo conhecido como PECVD (Plasma Enhanced Chemical Vapour Deposition). Os implantes foram inseridos em blocos de poliuretano e as coroas protéticas cimentadas sobre os pilares que foram parafusados aos implantes. O torque reverso foi mensurado após ciclagem mecânica (1.106 ciclos). A análise estatística foi realizada pelo teste Anova 1 fator e Teste de Tukey e Teste t-student com nível de significância de 5%. Resultados: A análise dos resultados mostraram que após a ciclagem mecânica o torque reverso RT(%) do grupo sem tratamento (A1) foi significativamente maior que a dos grupos DLC (A2) e CD-DLC (A3) (p=0,0001), para os parafusos das conexões HE. Entretanto não houve diferença estatística entre os grupos com e sem tratamento na manutenção do torque para os parafusos dos grupos de conexão HI (p= 0.5476). Conclusão: Nas condições estudadas, concluiu-se que os parafusos revestidos com filmes DLC não foram efetivos na manutenção do torque reverso em relação aos parafusos sem tratamento para ambas... / Abstract: Objective: To evaluate the values of reverse torque RT ( % ) of prosthetic screws titanium alloy coated with a film of diamond-like carbon (DLC) and DLC film doped with diamond particles (CD- DLC) comparing them with screws without treatment (control). Method: Sixty implants were divided into six groups according to the type of connection (external or internal hex) and type of abutment screw (n = 10 ): Group A1: external hexagon / screw control, Group A2: external hexagon / screw with DLC; group A3: external hexagon / screw with CD- DLC; group B1: internal hex / screw control; group B2: internal hex / screw with DLC; group B3: internal hex / screw with CD- DLC. The DLC films and CD - DLC were deposited by PECVD process (Plasma Enhanced Chemical Vapour Deposition). The implants were inserted into polyurethane resin, and crowns of nickel chrome cast were cimented and the abutments screwed into the implants. The reverse torque was measured after the mechanical cycling (1.106 cycles). Statistical analysis was performed by one factor ANOVA and Tukey's test, with significance level of 5%. Analysis was performed screws through scanning electron microscopy (SEM) before and after loading . Results: The results showed that after mechanical reverse torque RT (%) for the untreated group (A1) was significantly higher than the one of the DLC groups (A2) and CD -DLC (A3) (p = 0.0001). However, there was no statistical difference for the groups with and without coating in maintaining torque for the screws' internal hex connections (p = 0.5476). Conclusion: After mechanical cycling, the diamond-like carbon with and without doping of diamond on the screws for abutments, showed no improvement in maintaining the torque in external and internal hex connections... (Complete abstract click electronic access below) / Mestre
190

Avaliação da influência da quimioterapia com cisplatina ou 5-fluorouracil sobre o processo de reparo ósseo em implantes osseointegrados instalados em tíbias de ratos expostos ou não à nicotina /

Matheus, Henrique Rinaldi. January 2019 (has links)
Orientador: Juliano Milanezi de Almeida / Banca: Edilson Ervolino / Banca: Estevam Augusto Bonfante / Resumo: Objetivo: avaliar a influência da nicotina e dos agentes antineoplásicos Cisplatina (CIS) e 5-fluorouracil (5-FU) sobre os tecidos peri-implantares, bem como os efeitos desses agentes antineoplásicos sobre os tecidos peri-implantares em animais previamente expostos à nicotina. Material e métodos: 180 ratos machos (Wistar) foram randomizados para dois grandes grupos (n=90), NIC e SS, em seguida, para três subgrupos (n=30) de acordo com os agentes antineoplásicos. Receberam 0,5ml de solução de cloreto de sódio 0,9% (SS) ou 3 mg/kg de hemissulfato de nicotina (NIC), de acordo com cada grupo, 30 dias antes e 30 dias após a cirurgia. No dia 0, todos os animais receberam os implantes de titânio (DSP Biomedical®, 4 mm x 2,2 mm) nas tíbias direita e esquerda. Aos 30 dias após a cirurgia, as aplicações de SS e NIC foram interrompidas por 5 dias e, aos 35 e 37 dias, foram administrados os agentes antineoplásicos CIS, 5-FU ou 0,5 ml de SS, via intraperitoneal, respeitando intervalo de 48 h entre as aplicações. Para CIS, 5 mg/kg e 2,5 mg/kg, e para 5-FU, 60 mg/kg e 40 mg/kg, respetivamente. SS-SS: receberam SS via subcutânea e intraperitoneal. SS-CIS: receberam SS via subcutânea e CIS via intraperitoneal. SS-5FU: receberam SS via subcutânea e 5-FU via intraperitoneal. NIC-SS: receberam NIC via subcutânea e SS via intraperitoneal. NIC-CIS: receberam NIC via subcutânea e CIS via intraperitoneal. NIC-5FU: receberam NIC via subcutânea e 5-FU via intraperitoneal. Dez animais por grupo/período... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: to evaluate the influence of nicotine and the antineoplastic agents Cisplatin (CIS) and 5-fluorouracil (5-FU) over the peri-implant tissues, as well as the effects of these agents over peri-implant tissues in animals previously exposed to nicotine. Material and Methods: 180 male rats (Wistar) were initially randomized to two groups (n=90), NIC and SS. Then, to three subgroups (n=30) according to the protocol of antineoplastic agents. Received 0.5 ml of sodium chloride 0.9% (SS) or 3 mg/kg of nicotine hemissulfate (NIC) according to each group, subcutaneously, 30 days before and after surgical procedure for implants placement. At day 0, all animals received the titanium implants (DSP Biomedical®, 4 mm x 2.2 mm) in both right and left tibiae. At 30 days after surgery SS and NIC was interrupted, and at 35 and 37 days were intraperitoneally administered the antineoplastic agents CIS, 5FU or 0.5 ml SS, with 48 h interval between applications. For CIS, 5 mg/kg and 2,5 mg/kg, and 5-FU, 60 mg/kg and 40 mg/kg, respectively. SS-SS: received SS subcutaneously and intraperitoneally. SS-CIS: received SS subcutaneously and CIS intraperitoneally. SS-5FU: received SS subcutaneously and 5-FU intraperitoneally. NIC-SS: received NIC subcutaneously and SS intraperitoneally. NIC-CIS: received NIC subcutaneously and CIS intraperitoneally. NIC-5FU: received NIC subcutaneously and 5-FU intraperitoneally. Ten animals per group and period were euthanized at 50, 65 and 95 days after implants placement. The collected specimens were fixed in buffered formaldehyde solution 4% for 48h and assigned to ground section processing for analysis of bone/implant contact (BIC), or conventional histologic processing with demineralization and paraffin embedding for histometric analysis of percentage of newly-formed bone (PNFB) (Complete abstract electronic access below) / Mestre

Page generated in 0.0392 seconds