• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1383
  • 113
  • 47
  • 44
  • 44
  • 43
  • 26
  • 16
  • 13
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 1556
  • 886
  • 745
  • 656
  • 292
  • 235
  • 207
  • 162
  • 156
  • 140
  • 139
  • 138
  • 137
  • 136
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Efeito na osseointegração de um novo método de nanotexturização de superfície de implantes através de anodização /

Villaça-Carvalho, Maria Fernanda Lima. January 2016 (has links)
Orientador: Mari Eli Leonelli de Moraes / Co-orientador: Luana Marotta Reis de Vasconcellos / Banca: João Paulo Barros Machado / Banca: Natal Nerímio Regone / Banca: Maria Aparecida Neves Jardini / Banca: Sergio Lucio Pereira de Castro Lopes / Resumo: A Implantodontia é uma das áreas da Odontologia que mais tem evoluído nas últimas décadas. Diversos estudos são desenvolvidos na intenção de otimizar o processo de osseointegração utilizando a nanotopografia na superfície dos implantes. Atualmente o processo de anodização da superfície vem se destacando entre estas técnicas. Desta forma, o objetivo nesta pesquisa foi obter nano rugosidades e fase de anatase em implantes odontológicos de Titânio, buscando a otimização da osseointegração. Sessenta implantes foram caracterizados quanto à morfologia, por meio de microscopia de força atômica (AFM) e Microscopia Eletrônica de Varredura (MEV); quanto à composição química, por análise por detector de espectrometria por espalhamento de energia (EDS) e Espectroscopia Raman; e por fim, quanto ao potencial de corrosão, pela análise de impedância eletroquímica (EIE). A osteogênese, in vivo, foi comparada por Radiografia periapical (RP), Microtomografia Computadorizada (µTC) e teste de remoção por torque reverso; e, a análise in vitro, foi realizada por teste de citotoxicidade por MTT [(brometo de 3-4,5-dimetiltiazol-2-il)-2,5-difeniltetrazoliol]. Os implantes foram divididos em: G1 (controle); Grupo 2 (jateado); Grupo 3 (anodizadoexperimental). Cada coelho recebeu um implante de cada grupo nas tíbias direita e esquerda, e cinco coelhos, foram eutanasiados 2 e 6 semanas após a cirurgia. Os implantes da tíbia direita foram submetidos à RP e à µTC; e os da tíbia esquerda, ao teste de torque reverso e análise de citotoxicidade por MTT. AFM e MEV comprovaram a presença de nano rugosidades na superfície em G3; análises de EDS e Espectroscopia Raman, demonstraram aumento da camada do filme de TiO2 e a obtenção de anatase em G3. Na RP, nenhum implante apresentou halo radiolúcido. Na µTC, G3 foi sempre superior aos demais grupos nos parâmetros observados: BV, BV/TV, Tb.Th. No teste de torque reverso, houve... / Abstract: The Implantology is one of the areas of dentistry that has most evolved in recent decades. Many studies have been developed with the intention of optimizing the osseointegration process using nanotopography on the surface of the implants. Currently the surface of the anodizing process has stood out among these techniques. Thus, the aim of this research was to obtain nano roughness and anatase phase in dental Titanium implants, seeking for the optimization of the osseointegration. Sixty implants were characterized for morphology by atomic force microscopy (AFM) and Scanning Electron Microscopy (SEM); in chemical composition, by mass spectrometry detector energy scattering (EDS) and Raman spectroscopy; and finally, as the potential for corrosion, the electrochemical impedance analysis (EIS). Osteogenesis in vivo was compared by Periapical Radiography (PR), Computed Microtomography (μTC), removal reverse torque test; and in vitro analysis, it was performed by MTT cytotoxicity assay [(bromide 3-4,5-dimethylthiazol-2-yl) -2,5-difeniltetrazoliol]. The implants were divided into G1 (control); Group 2 (sandblasted); Group 3 (anodized-experimental). Each rabbit received an implant of each group in the right and left tibias and five rabbits were euthanized 2 and 6 weeks after surgery. The implants of the right tibia underwent PR and μTC; and the left tibia, the reverse torque test and MTT cytotoxicity assay. AFM and SEM confirmed the presence of nano roughness on the surface in G3; EDS analysis and Raman spectroscopy showed increased TiO2 film layer and obtainment of anatase G3. In PR, no implant presented radiolucent halo. In μTC, G3 has always been higher than the other groups in the observed parameters: BV, BV / TV, Tb.Th. In the reverse torque test, It was required greater removal force of anodized implants. In the MTT test, the experimental implants were nontoxic to cells. It was conclude that the anodizing process used in this study... / Doutor
142

Avaliação da microinfiltração bacteriana nas interfaces entre pilares e implantes /

Faria, Renata. January 2008 (has links)
Orientador: Marco antonio Bottino / Banca: Nelson Luiz de Macedo / Banca: Francisco Fernando Todescan / Banca: Diego Klee de Vasconcellos / Resumo: O objetivo nesta pesquisa foi avaliar a infiltração bacteriana in vitro na interface entre o pilar e o implante, comparando-se três tipos de conexões protéticas: Hexágono Externo (HE), Hexágono Interno Indexado (HII) e Cone Morse (CM). Sob condições estéreis, foi inoculada colônia de Escherichia coli na porção apical do parafuso do pilar. Após, os pilares foram fixados aos implantes com torque de 20 N/cm. Foram descartadas as amostras que apresentaram contaminação externa imediata. As amostras foram colocadas em tubos de ensaios contendo 2 ml de caldo TSB estéril. Em acompanhamento diário, por 7 dias, os caldos que se apresentaram turvos foram semeados em placa de petri com TSA e incubados em estufa bacteriológica à 37oC por 24 horas, para a observação de crescimento bacteriano. Coloração Gram foi realizada tanto no caldo quanto na colônia resultante da semeadura, para comprovação da presença de E. coli (Gram-negativo). Ao final do período, todas as amostras foram separadas, o conteúdo interno foi coletado com cone de papel e solução salina e semeado em placas de petri contendo TSA, levadas à estufa bacteriológica a 37º C por, 24 horas para verificar a viabilidade das bactérias. As amostras que não continham E.coli viáveis no seu interior foram descartadas do resultado final. Após os descartes por contaminação externa e inviabilidade, obtiveram-se os seguintes números de amostra: 38 (HE), 40 (HII) e 41 (CM). Os resultados, em % de amostras com infiltração bacteriana, foram submetidos ao teste de comparações múltiplas de proporções. As curvas de sobrevivência foram analisadas pelo método de Kaplan-Meyer e comparadas pelo teste estatístico de Log-Rank. Não houve diferença entre HE (10,53%), HII (4,88%) e CM (7,50%). As curvas de sobrevivência não diferiram entre si. A infiltração bacteriana ocorreu de modo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate, in vitro, the bacterial leakage between implant and abutment comparing three kinds of implantabutments connections: extern hexagon (EH), indexed intern hexagon (IIH) and morse-taper (MT). Under sterile controlled conditions, the tip of the abutment screw was inoculated with Escherichia coli culture and then the abutment was placed in position and tightened (20N/cm). The specimen was discarded if an external contamination of the outer surface was observed. Each specimen was incubated in a glass tube containing 2mL of sterile TSB medium at 37oC. The growth of E. Coli in the medium was registered every 24h. Once the sample showed cloudy broth, it was individually plated on TSA plates and incubated in an anaerobic chamber at 37oC for 24h, in order to observe the bacterial growth. Gram test was performed both in the medium and in the culture to certify the presence of E. Coli (Gram negative). After 7 days, each test specimen was sampled using a sterile paper point which was incubated in TSA plates and incubated in anaerobic chamber at 37oC for 24h, to verify bacterial viability. Samples that did not show bacterial viability in the end of the study were eliminated from the final results. After that, there were 38 EH samples, 40 IIH samples and 41 CM samples. The results, in %, of bacterial leakage, were statistically evaluated by multiple comparisons for proportion. The survival curves were analyzed by Kaplan-Meyer method and compared by statistical test of Log-Rank. There was no statistical difference among EH (10,53%), IIH (4,88%) e MT (7,50%). The three survival curves did not differ (p>0.005). It was conclude that the bacterial leakage occurred in a similar way for the three kinds of implant-abutment interface, no matter the assembly configuration. / Doutor
143

Modificação de superfície empregando-se laser e recobrimento de implantes dentários de titânio com apatitas /

Braga, Francisco José Corrêa January 2007 (has links)
Orientador: Antonio Carlos Guastaldi / Banca: Idelmo Rangel Garcia Junior / Banca: Pedro Iris Paulin Filho / Banca: Luis Gallego Martinez / Banca: José Carlos Bressiani / Resumo: Os implantes orais em titânio e suas ligas biocompatíveis vêm nas últimas três décadas acentuando o seu aprimoramento funcional quanto às suas quatro principais propriedades esperadas: protocolo cirúrgico, projeto mecânico, sistema de acoplamento protético e tratamento de superfície. A proposta deste trabalho está focalizada nesta última propriedade. Diversos tipos de tratamento de superfície vêm atualmente sendo oferecidas ao mercado com o propósito de favorecer a catálise do fenômeno de osseointegração, o aumento de área de contato com o tecido ósseo calcificado, e resistência à corrosão pelo organismo. O processo atualmente considerado mais limpo é caracterizado pela irradiação por feixe de laser, onde a superfície do implante não sofre nenhuma interação com outro qualquer material para a sua modificação. O presente estudo correlaciona as condições paramétricas do feixe de laser Nd:YVO4 aplicado ao titânio comercialmente puro (cp) e sua liga Ti6Al4V com os tipos de topografia e compostos formados na superfície destes metais, como também com as características de adesão à camada de apatita depositada pelo método biomimético. Os métodos de análise e caracterização realizados neste estudo foram essencialmente físico-químicos como WDXRF, MEV, EDS, DRX, MFA, FTIR, Rugosimetria, Molhabilidade e Ensaio de Flexão. Palavras-chaves: biomateriais; laser; implante; titânio; apatita; biomimético. / Abstract: From three decades ago to nowadays, oral implants made of metallic titanium and its biocompatible alloys had a great functional improvement referred to their four most important properties: surgical protocol, mechanical design, prosthesis/implant attachment system and surface modification processes. The scope of the present paper is focused on this last property. Several types of surface treatment in implants are offered due to the market appeal in improvements as the osteointegration process catalysis, augmentation of the bone/implant contact surface area and corrosion resistance to the organism aggression. Today, the most clean surface modification process is technological based in laser beam irradiation where the modified surface does not has contact with any tool or material to be treated. The present study correlates the laser beam parameters arrangement irradiating commercially pure metallic titanium and Ti6Al4V alloy with the resulting surface topography, the formed crystalline fases and as wel as the adhesion capacity to apatite deposition by biomimetic process. The used physical-chemistry analytical and characterization methods in this study were WDXRF, SEM, EDS, XRD, MFA, FTIR, rugosimetry, wetness and flexural mechanical test. KEY-WORDS: biomaterials; laser; implant; titanium; apatite; biomimetic. / Doutor
144

Estudo das modificações na superfície do Ti cp titânio comercialmente puro e da liga Ti-6AI-4V usados como biomateriais utilizando-se deposição por plasma spray /

Alencar, Anselmo Colombo de. January 2002 (has links)
Orientador: Antonio Carlos Guastaldi / Resumo: Este trabalho estudou-se a superfície do Ti cp e a liga metálica de Ti-6Al-4V usados como biomateriais para implantes, antes e após a modificação superficial (revestimento) empregando-se a aspersão térmica de dióxido de titânio por meio da técnica de plasma spray. A finalidade deste tratamento foi produzir um suporte funcional e quimicamente adequado possuindo grande área específica favorável para uma posterior osseointegração, o que garante uma melhor adesão do osso regenerado à superfície do implante usado para a prótese. A caracterização realizou-se usando métodos instrumentais: análise química, microscopia eletrônica, análise metalográfica, ensaios de dureza e difratometria de raios X do Ti cp, da liga, do composto de partida e do revestimento após a deposição. Conforme a microscopia eletrônica de varredura - MEV com EDS - a superfície do revestimento apresenta uma morfologia porosa e altamente homogênea. Os difratogramas de raios X do revestimento mostraram a presença de monóxido de titânio defeituoso e Ti2O3 . Na análise pontual de EDS, na região da interface, observou-se a difusão dos elementos Al e V da liga para o revestimento, e do oxigênio do revestimento para o substrato. Conclui-se que a presença de TiO e Ti2O3 na superfície está relacionada com a decomposição térmica do dióxido de titânio no jato de plasma spray com uma posterior recombinação dos seus componentes na forma de sesquióxido Ti2O3 e intercalação de oxigênio formando soluções sólidas superficiais de composição TiO1-x. A morfologia porosa e a presença destas fases no revestimento permite recomendar esta metodologia para a fixação do implante quando aplicado clinicamente. / Abstract: The surface of cp Ti and Ti-6Al-4V alloy for implants was studied before and after the superficial modification (coating) using the technique of titanium dioxide spraying with plasma-gun. The purpose of such a treatment was to create functional and chemically appropriate metal support having large specific area favorable for the posterior osseointegration which will guarantee a better adhesion of the regenerated bone to the surface of the implant used for the prostheses. The characterizations have been carried out by using instrumental techniques: chemical analysis. electron microscopy, metallography, hardness tests and X rays diffraction study of cp Ti, alloy, starting oxide and coating after the deposition. According to the morphology studies performed by scanning electron microscopy, the coating surface is porous and exhibits high homogeneity. The coating X ray pattern showed the presence of both defectuous titanium monoxide and Ti2O3. Point EDS analysis of the interface region permitted to observe aluminum and vanadium diffusion from alloy to the coating and that of oxygen from the coating to substract. It is to conclude that the presence of TiO and Ti2O3 on the surface is owing to the thermal decomposition of titanium dioxide in the plasma jet spray followed by the recombination of its components in the form of Ti2O3 and oxygen insertion producing superficial solid solutions of the composition TiO1-x. The porous morphology and the presence of the above phases in the coating allows to recommend this technique for the implant fixation in clinics. / Doutor
145

Torque de remoção de implantes lisos e texturizados com e sem estabilidade primária associados ou não ao plasma rico em plaquetas

Suzuki, Roberto Makoto January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:00Z (GMT). No. of bitstreams: 2 000399345-0.pdf: 1607663 bytes, checksum: 3e900d3262bbff08d819d4414119f515 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Rough implant surfaces and platelet-rich plasma are thought to enhance titanium osseointegration. Torque removal forces have been used as a biomechanical measurement of endosseous integration or bone anchorage, in which higher forces required to remove implants from the bone may be interpreted as an increase in the strength of bony integration. The purpose of this study was to evaluate the effect of primary stability of machined implants (MI) and sandblasted/acid-etched (SBAE) titanium implants associated with platelet-rich plasma (PRP) on the resistance to reverse torque removal. These factors were evaluated in six groups: 1- MI with primary stability and without PRP; 2- MI without primary stability and without PRP; 3- MI without primary stability and with PRP; 4- SBAE with primary stability and without PRP; 5- SBAE without primary stability and without PRP; 6- SBAE without primary stability and with PRP. Forty two implants were inserted in seven adult New Zealand white rabbits (Oryctolagos Cuniculus L. ). Three implants were inserted in each tibiae according to the above described groups. After a healing period of 9 weeks the animals were sacrificed and the implants were removed by reverse torque rotation with a digital torque-measuring device. Mean torque values were: 1- 53,01 Ncm (±9,68); 2- 45,29 Ncm (±16, 90); 3- 43,43 Ncm (±16,70); 4- 56,60 Ncm (±16,00); 5- 46,89 Ncm (±15,60) and 6- 48,49 Ncm (±17,06), respectively. No significant difference was detected among the groups (p>0,05). In this study it was not possible to demonstrated a statistically significant improved stability of implants subjected to PRP and texturized implants as compared to other groups. / O objetivo desse estudo foi avaliar o torque de remoção de implantes lisos e texturizados sem estabilidade primária associados a plasma rico em plaquetas. Foi utilizado um total de sete coelhos fêmeas, brancas da raça Nova Zelândia Branco (Oryctolagos cuniculus l. ). Em cada coelho foram instalados 6 implantes, 3 para cada tíbia, de acordo com os seguintes grupos experimentais: 1- implante liso com estabilidade primária e sem PRP (plasma rico em plaquetas); 2- implante liso sem estabilidade primária e sem PRP; 3- implante liso sem estabilidade primária e com PRP; 4- implante texturizado com estabilidade primária e sem PRP; 5- implante texturizado sem estabilidade primária e sem PRP; 6- implante texturizado sem estabilidade primária e com PRP. Os protocolos cirúrgicos foram aplicados de acordo com cada grupo experimental e após um período de 9 semanas, os animais foram mortos. Logo após a morte dos animais, a mensuração do torque de remoção foi realizada. As médias dos grupos foram: grupo 1, 53,01 Ncm (±9,68); grupo 2, 45,29 Ncm (±16, 90); grupo 3, 43,43 Ncm (±16,70); grupo 4, 56,60 Ncm (±16,00); grupo 5, 46,89 Ncm (±15,60) e grupo 6, 48,49 Ncm (±17,06). Os dados foram analisados através da Análise de Variância Múltipla, utilizando o delineamento em blocos casualizados que demonstrou não haver diferença estatística entre os grupos ao nível de 5% nas condições experimentais estabelecidas. As distintas condições experimentais não foram capazes de promover diferença no torque de remoção.
146

Aderências peritoniais, colágeno tipo I, III e total nas telas de polipropileno e polipropileno revestido : estudo experimental em ratos

Rossi, Lucas Félix January 2013 (has links)
Introdução: A correção herniária é um tratamento realizado rotineiramente na prática cirúrgica. O aprimoramento da técnica operatória e dos materiais disponíveis trouxe sem dúvida enorme benefício na qualidade dos resultados da cirurgia. A inserção de próteses para correção herniária é bem embasada na literatura e tornou-se o padrão de tratamento quando abordamos este tipo de doença. O objetivo deste trabalho é avaliar duas próteses disponíveis: a de polipropileno e a de polipropileno revestido em modelo experimental. Métodos: Foram inseridas sete próteses de cada tipo em ratos Wistar (Ratus norvegicus albinus) na parede abdominal anterior do animal em contato direto com as vísceras. Após o seguimento de noventa dias fizemos a análise das aderências intra-abdominais, bem como avaliação por imuno-histoquímica e videomorfometria do colágeno total, tipo I e tipo III. Ainda fez-se a análise histológica com hematoxilina-eosina para avaliação dos tipos celulares presentes em cada tela. Resultados: Aos noventa dias as aderências não foram diferentes entre os grupos (P=0,335). O colágeno total igualmente não foi estatisticamente diferente (P=0,810). O colágeno tipo III foi estatisticamente maior no grupo polipropileno revestido (P=0,039) enquanto o colágeno tipo I não diferiu entre as próteses (P=0,050). Os linfócitos foram estatisticamente mais presentes no grupo polipropileno (P=0,041). Conclusão: A prótese revestida não foi diferente da de polipropileno na variável aderência. O colágeno total e tipo I não foram diferentes entre os grupos enquanto que o colágeno tipo III é mais presente na tela revestida. O número de linfócitos foi maior na tela de polipropileno.
147

Aderências peritoniais, colágeno tipo I, III e total nas telas de polipropileno e polipropileno revestido : estudo experimental em ratos

Rossi, Lucas Félix January 2013 (has links)
Introdução: A correção herniária é um tratamento realizado rotineiramente na prática cirúrgica. O aprimoramento da técnica operatória e dos materiais disponíveis trouxe sem dúvida enorme benefício na qualidade dos resultados da cirurgia. A inserção de próteses para correção herniária é bem embasada na literatura e tornou-se o padrão de tratamento quando abordamos este tipo de doença. O objetivo deste trabalho é avaliar duas próteses disponíveis: a de polipropileno e a de polipropileno revestido em modelo experimental. Métodos: Foram inseridas sete próteses de cada tipo em ratos Wistar (Ratus norvegicus albinus) na parede abdominal anterior do animal em contato direto com as vísceras. Após o seguimento de noventa dias fizemos a análise das aderências intra-abdominais, bem como avaliação por imuno-histoquímica e videomorfometria do colágeno total, tipo I e tipo III. Ainda fez-se a análise histológica com hematoxilina-eosina para avaliação dos tipos celulares presentes em cada tela. Resultados: Aos noventa dias as aderências não foram diferentes entre os grupos (P=0,335). O colágeno total igualmente não foi estatisticamente diferente (P=0,810). O colágeno tipo III foi estatisticamente maior no grupo polipropileno revestido (P=0,039) enquanto o colágeno tipo I não diferiu entre as próteses (P=0,050). Os linfócitos foram estatisticamente mais presentes no grupo polipropileno (P=0,041). Conclusão: A prótese revestida não foi diferente da de polipropileno na variável aderência. O colágeno total e tipo I não foram diferentes entre os grupos enquanto que o colágeno tipo III é mais presente na tela revestida. O número de linfócitos foi maior na tela de polipropileno.
148

Estudo Prospectivo da Associação entre Polimorfismos Ligados à Remodelação Óssea e o Insucesso de Implantes Dentários

Texeira, Camila Epitácio Cravo 31 January 2014 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-04-08T17:56:32Z No. of bitstreams: 2 DISSERTAÇÃO Camila Eptácio Cravo Teixeira.pdf: 619895 bytes, checksum: db1cbb0b8e535192f130230b48c0357f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-08T17:56:32Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO Camila Eptácio Cravo Teixeira.pdf: 619895 bytes, checksum: db1cbb0b8e535192f130230b48c0357f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014 / CNPq / Objetivos: Verificar a relação entre polimorfismos genéticos ligados às citocinas da remodelação óssea osteoprotegerina (OPG) e o ligante do ativador do receptor do fator nuclear kappa B (RANKL), relacionar a presença de polimorfismos em OPG e RANKL com o insucesso clínico dos implantes dentários ao longo do tempo e determinar quais combinações de polimorfismos de OPG e RANKL estão associados ao insucesso de implantes dentários. Materiais e métodos: Vinte pacientes de ambos os sexos, maiores de dezoito anos, reabilitados no total com trinta e quatro implantes dentários e avaliados a cada seis meses durante um ano participaram do estudo. Após o exame clínico e radiográfico, os pacientes foram divididos no grupo de insucesso dos implantes, caso um ou mais do seguintes critérios fossem encontrados: mobilidade; queixas subjetivas persistentes; infecção peri-implantar recorrente com supuração; radiolucência contínua ao redor do implante; profundidade de sondagem ≥ 5mm e sangramento à sondagem; e grupo de sucesso, se nenhuma das características acima fossem identificadas. Foi coletado sangue periférico para a análise do polimorfismo das citocinas de OPG e RANKL através da reação em cadeia da polimerase (PCR). Resultados: Não houve diferença estatisticamente significante entre o grupo de falha dos implantes em relação ao genótipo de OPG e RANKL. Conclusão: Os polimorfismos de OPG e RANKL não influenciam no insucesso dos implantes dentários ao longo do tempo de estudo.
149

Efeito de tres diferentes tipos de substitutos osseos sobre a osseointegração primaria de implantes endosseos : avaliação histologica em tibias de coelhos

Sardinha, Sandra de Cassia Santana 02 June 2001 (has links)
Orientador: Renato Mazzonetto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T17:47:20Z (GMT). No. of bitstreams: 1 Sardinha_SandradeCassiaSantana_M.pdf: 6176162 bytes, checksum: 1d0646d2b9cfeffe8d23ed9b139c8ee0 (MD5) Previous issue date: 2001 / Resumo: Este trabalho teve como objetivo analisar histologicamente o comportamento do polímero de mamona, do osso humano desmineralizado e do sulfato de cálcio associados a implantes de titânio comercialmente puro, com 2,6 mm de diâmetro e 6 mm de comprimento. Os experimentos foram realizados em ambas as tíbias de 10 coelhos da raça Nova Zelândia, com idade variando entre 6 e 8 meses e peso médio de 3,9 kg. Nas perfurações realizadas em cada tíbia foram colocados o material e o implante, sendo que na perfuração proximal da tíbia direita o implante permaneceu envolvido apenas por sangue, que serviu como controle. Após o período de 12 semanas os animais foram sacrificados e blocos ósseos contendo os implantes, foram fixados, descalcificados e processados para posterior análise histológica em microscopia óptica comum. Os resultados mostraram neoformação óssea e vascular, sem a presença de reação inflamatória do tipo corpo estranho em todos os grupos estudados, não havendo diferenças teciduais locais entre os mesmos / Abstract: The prupose of this study was to evaluate the histoligic behavior of castor plant oil polymer, demineralized Iyophilized human bone, and calcium sulfate when associated with a commercially pure titanium implant. Ten New Zealand rabbits were utilized in this study. The animal age ranged from 6 and 8 months and the mean weight was 3,9kg. Perforations of 2,6mm of diameter and 6mm of depth were drilled in both tibia of each rabbit. The left proximal and distal, and right distal tibia perforations were filled with castor plant oil polymer, demineralized Iyophilized human bone and calcium sulfate, respectively. Each material was combined with a commercially pure titanium implant. The right proximal tibia perforation was filled with commercially pure titanium implant and blood clot to serve as a control group. After a 12 weeks, the rabbits were sacrificed and paraffin blocks of each specime were histologically analyzed. The results showed that ali three materials evaluated did not impede appropriate angionesis and osteogenesis. In addition, there was no histologic evidence of foreign body reaction in any of the implant sites. We ca conclud that there was no difference among ali groups with respect to the interference with angiogenesis and osteogenesis. Furthermore, there was no histologic evidence of rejection of the three materials studied. / Mestrado / Cirurgia / Mestre em Clínica Odontológica
150

Avaliação da influencia da nicotina sobre o reparo osseo ao redor de implantes de titanio com diferentes tratamentos de superficie colocados em tibias de coelhos

Stefani, Cristine Miron 17 August 2001 (has links)
Orientador: Francisco Humberto Nociti Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T10:59:34Z (GMT). No. of bitstreams: 1 Stefani_CristineMiron_D.pdf: 2230659 bytes, checksum: 65f2d179832aebbd74d049ecbf00415b (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a influência da nicotina sobre o reparo ósseo ao redor de implantes de titânio com diferentes tratamentos de superfície colocados em tíbias de coelhos. Trinta e dois coelhos Nova Zelândia, adultos, fêmeas, sob anestesia geral, receberam dois implantes de titânio em cada tíbia, sendo dois usinados e dois jateados com óxido de alumínio. Os animais foram sorteados para receber um dos seguintes tratamentos: a) solução fisiológica, b) 0,18 mg de nicotina /Kg de peso corporal/dia; c) 0,56 mg/Kg/dia; d) 0,93 mg/Kg/dia, através de injeção subcutânea. Após a inserção dos implantes, aos sete e 14 dias, receberam aplicação intramuscular de solução de calceína a 2%, para marcação do tecido ósseo neoformado. Os animais foram sacrificados 42 dias após a colocação dos implantes. Secções não descalcificadas foram avaliadas histometricamente e através de microscopia de fluorescência para os parâmetros: intensidade da marcação do tecido ósseo neoformado, área relativa do tecido ósseo por rosca do implante e extensão relativa de tecido ósseo em contato direto com a superfície do implante. Os dados obtidos foram comparados estatisticamente pelo teste ANOV A. Houve diferença estatística significativa (p=0,015) para o parâmetro extensão do tecido ósseo em contato direto com a superfície do implante entre os implantes com superfície tratada quando comparados aos de superfície usinada, para os grupos que receberam nicotina C e D (37,85% +- 8,85 e 30,13% +- 4,97; 33,13% +- 8,87 e 27,79% +- 3,93, respectivamente). Dentro das condições experimentais empregadas, foi possível concluir que a nicotina não influenciou o reparo ósseo ao redor dos implantes de titânio para os parâmetros avaliados. E implantes com superfície tratada favoreceram a extensão de tecido ósseo em contato direto com a superfície do implante nos animais tratados com nicotina / Abstract: The present study investigated the possible influence of nicotine on the bone healing process around machined and rough surfaced titanium implants inserted in the tibiae of rabbits. Thirty-two female New Zealand rabbits were included. After anesthesia, the tibiae surface was exposed and two screw-shaped commercially available pure titanium implants 7.0 mm in length and 3.75 mm in diameter were placed bilaterally. A total of 128 implants were inserted: 64 with a rough surface rnish (aluminum oxide blasted) and 64 with a machined surface finish. The animals were randomly assigned to one of the four treatment groups, including daily subcutaneous injections of nicotine: a) saline solution, b) 0.18 mg/Kg, c) 0.56 mg/Kg and d) 0.93 mg/Kg. In order to label regenerated bone a 2% calcein green solution was administered by intramuscularly injection at O, 7, 14 days after implant insertion. After 42 days, the animals were sacrificed and undecalcified sections were prepared. The degree of bone contact with the implant surface, the bone area and the intensity of bone labeling were measured into the limits of the threads of the implant. Two way ANOV A were used to compare the results. Statistically significant difference was found for the degree of bone contact with the implant surface between smooth and rough surfaces finishes for C and D groups (30,13% +- 4,97 and 37,85% +- 8,85; 27,79% +- 3,93 and 33,13% +- 8,87, respectively, P=0,015). Within the limits of the present study, it was concluded that nicotine had no effect on the bone repair around titanium implants inserted in rabbit tibiae, and rough surfaced. In implants improved bone/implant contact for nicotine groups / Doutorado / Periodontia / Doutor em Clínica Odontológica

Page generated in 0.0698 seconds