• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1383
  • 113
  • 47
  • 44
  • 44
  • 43
  • 26
  • 16
  • 13
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 1556
  • 886
  • 745
  • 656
  • 292
  • 235
  • 207
  • 162
  • 156
  • 140
  • 139
  • 138
  • 137
  • 136
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Análise e comparação da interface implante/pilar de pilares de zircônia usinados por tecnologia CAD/CAM sobre implantes HE.

Rodríguez Ivich, Elí Jair January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia, Florianópolis, 2016 / Made available in DSpace on 2016-09-20T04:45:20Z (GMT). No. of bitstreams: 1 340525.pdf: 1688167 bytes, checksum: 70875b398c49ad9d4d9b2835008966ec (MD5) Previous issue date: 2016 / O objetivo deste estudo foi determinar a precisão marginal de diferentes pilares de zircônia usinados por sistemas de CAD/CAM instalados sobre implantes Hexágono Externo. Foram utilizados doze implantes de hexágono externo Easy Grip (Conexão Sistema de Prótese Ltda) de 10mm de comprimento e 4.0 mm de diâmetro. Foram utilizados quatro tipos de pilares: Grupo 1 Pilares de titânio pré-fabricados (30 N); Grupo 2 Pilares de zircônia: Dental Wings (20 N); Grupo 3 Pilares de zircônia: 3Shape (20 N); Grupo 4 Pilares Ti-base: (CEREC, Sirona) (35 N). As amostras foram apreendidas em um porta-amostra e segmentadas ao longo eixo. A espessura da interface implante-pilar foi mensurada por microscopia óptica em 6 diferentes pontos. Os valores da análise de variância resultaram que os tamanhos da interface do grupo 1 (Ti) foram significativamente menores do que os observados nos pilares ceâmicos (P <0,05). Os valores da interface do grupo 1 (Ti) não foram significativamente diferentes aos valores do grupo 4 (P>0.05). No entanto, foi encontrada uma diferença significativa entre as interfaces dos pilares de titânio (grupo 1 e 4) em comparação com os pilares de zircônia (grupo 2 e 3). Dentro dos limites deste estudo, mostrou-se que os pilares de zircônia não podem ser usinados com o mesmo grau de precisão que os pilares metálicos. As consequências mecânicas e o risco de infiltração microbiana da interface implante-pilares de zircônia devem ser avaliados em investigações clínicas. <br> / Abstract : The aim of this study was to determine the marginal accuracy of different zirconia abutments machined by CAD/CAM systems screwed on external hexagon implants. Twelve external hexagon (HE) ( Easy Grip, Prosthesis System Connection Ltd.) implants (10mm long and 4.0 mm) were used. Four types of abutments were used: Group 1 - prefabricated titanium abutments (30 N); Group 2 - zirconia abutments: Dental Wings (20 N); Group 3 - zirconia abutments: Tree Shape (20 N); Group 4 - Ti-base abutmetns: CEREC (35 N). The samples were placed in a sample port and segmented through the long axis. The thickness of the implant-abutment interface was measured by optical microscopy in 6 different points. One-way ANOVA have shown that the interfacial gaps from group 1 (Ti) were significantly lower than those observed in zirconia abutments (P <0.05), but were not significantly different from the values of Group 4 (P> 0.05). However, a significant difference was found between the interfaces of titanium abutments (Groups 1 and 4) compared with the zirconia abutments (Groups 2 and 3). Within the limits of this study showed that the zirconia abutments can not be machined with the same degree of precision as the metal abutments. The mechanical effects and the risk of microbial infiltration of zirconia implant-abutment interface should be evaluated in clinical research.
122

Análise clínica e tomográfica para aumento horizontal com uso de bloco autógeno e xenógeno

Araújo, Patrícia Medeiros January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:59:10Z (GMT). No. of bitstreams: 1 340528.pdf: 1937109 bytes, checksum: 7b7fbfa1716fb4a50c0adad122ccac10 (MD5) Previous issue date: 2016 / O presente estudo teve como objetivo comparar um substituto ósseo xenógeno com osso autógeno em bloco para aumento horizontal. Foram operados 23 sitios cirúrgicos que receberam enxerto ósseo em bloco, em 11 pacientes. Os pacientes foram submetidos a TCCB nos tempos inicial (T0), imediato a cirurgia (T1) e após seis meses (T2). As imagens foram analizadas no programa Image J 1.45® versão para Windows para análise do ganho em espessura. Os grupos foram divididos em nove para osso bovino inorgânico (OBI) Orthogen®/Baummer e 14 para Osso Autógeno (AO) e um total de 23 implantes instalados com 100% de sobrevivência. Houve diferença significamente estatístística para T2 com valores de p>0,005 Crista do Rebordo(CR) ,p>0,005 Médio(M) , p>0,011 Apical (A) e para o Ganho Real (T2-T0) também houve diferença significamente estatística em todos os terços (p>0,001 CR, p> 0,001 M, p>0,007 A). Quanto ao torque de estabilidade primária em correlação com a espessura dos tecidos, não houve diferença estatística. Conclui-se que o osso bovino desproteínado obteve resultados favoravávies, sendo assim seu uso é previsível para pequenos ganhos.<br> / Abstract : This study aim to compare a xenograft bone substitute with autogenous bone block for horizontal augmentation. Twenty three surgical sites were operated that received bone graft block in eleven patients. Patients were submmited to TCCB in the initial time (T0), immediate surgery (T1) and after six months (T2). The images were analyzed in the program Image J 1:45® Windows version to gain in thickness analysis. Groups were divided in nine to inorganic bovine bone (OBI) Orthogen® / Baummer and 14 for autogenous bone (AO) and a total of 23 implants at 100% survival. There were statistically significant differences in T2 with p> 0.005. Alveolar Crest (AC), p> 0.005 Medio (M), p> 0.011 Apical (A) and also to Real Gain (T2-T0) in all thirds ( p> CR 0.001, p> 0.001 M p> 0.007 A). There was no statistical difference as for the torque primary stability in correlation with the thickness of the tissue. It follows that the deproteinated bovine bone favorable results obtained, so its use is expected for small gains.
123

Implantes zigomáticos na reabilitação do sistema estomatognático

Hochheim Neto, Ricardo January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catatina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T13:44:00Z (GMT). No. of bitstreams: 1 188419.pdf: 3441391 bytes, checksum: b6dddccf6f92978c31fa50da6f336c90 (MD5) / Os implantes zigomáticos são alternativas recentemente desenvolvidas para minimização de procedimentos cirúrgicos que necessitem de grandes enxertos ósseos em maxilas extremamente atrésicas com diminuição de tempo e morbidade dos procedimentos cirúrgicos e protéticos. Duas técnicas cirúrgicas serão comparadas a técnica convencional desenvolvida pelo Dr Per Ingvar Branemark(NOBEL BIOCARE),para chegarmos a conclusões neste trabalho de dissertação
124

Mensuração do calor friccional gerado pelo preparo do tecido ósseo em implantodontia

Andriani Júnior, Wilson January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T13:51:28Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:40:00Z : No. of bitstreams: 1 182533.pdf: 3248629 bytes, checksum: df6bcf911d5984160dc71eb1f7cadfe2 (MD5) / O objetivo deste estudo in vitro foi desenvolver um dispositivo para avaliar o desempenho dos sistemas de irrigação interna e externa em implantodontia. A amostra foi composta de 20 espécimens ósseas de origem bovina. Dez espécimens foram submetidas a perfurações com as brocas do sistema 3i utilizando-se irrigação interna. Nas outras dez espécimens utilizou-se irrigação externa. Os resultados obtidos foram submetidos a tratamento estatístico. Na comparação individual das interações entre o tipo de broca e de irrigação testados, os resultados indicam que a broca 2,3 mm quando utilizada com irrigação externa provocou maior diferença de temperatura entre os momentos inicial e final , que todas as outras situações testadas. Dessa forma observou-se, neste estudo, que o sistema de irrigação interna gerou menor calor que o sistema de irrigação externa.
125

Influência dos tratamentos térmicos na microestrutura e nos micromecanismos de fratura da liga ti-6al-4v produzida por sinterização direta de metal por laser (DMLS)

Roque, Lidiane Kümpel [UNESP] 31 August 2015 (has links) (PDF)
Made available in DSpace on 2016-03-07T19:21:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-31. Added 1 bitstream(s) on 2016-03-07T19:25:29Z : No. of bitstreams: 1 000859657.pdf: 11263749 bytes, checksum: 51e907f4fbdf0d8ce56785c1c9af062c (MD5) / A liga Ti-6A-4V é um biomaterial que tem se mostrado muito adequado na fabricação de implantes para reparar lesões craniofaciais. Entre outros requisitos, é importante que o implante resista a solicitação mecânica para garantir uma resposta clínica satisfatória de modo a proporcionar conforto e segurança ao paciente. O propósito específico do presente trabalho de pesquisa é determinar a influência de diferentes ciclos térmicos na microestrutura da amostra da Ti-6Al-4V produzida pelo processo de sinterização direta de metal por laser (DMLS) e no micromecanismo de fratura resultante de tensionamento uniaxial em tração. Para isso foram fabricados corpos-de-prova de tração, utilizando a técnica DMLS, e os mesmos foram submetidos a diferentes ciclos térmicos de 650 °C/1h, 650 °C/3h, 800 °C/4h e 850 °C/2h. Posteriormente, os corpos-de-prova foram submetidos a ensaios de tração. A caracterização microestrutural foi realizada com auxílio de microscopia óptica (MO) e eletrônica de varredura (MEV). As superfícies de fratura resultantes para as diferentes condições de ciclos térmicos foram analisadas por microscopia eletrônica de varredura. A microestrutura final da amostra como produzida resultante do processo de manufatura aditiva por DMLS revelou uma microestrutura martensita hexagonal α'. Para a amostra A6501H, a microestrutura martensítica resultante do processo DMLS não se decompôs. Na amostra A6503H a microestrutura martensítica começa a se decompor, pois são observados precipitados da fase β. Já nas amostras A8004H e A8502H observa-se uma estrutura (α +β), com cristais de fase α e fase β precipitada nos contornos. De acordo com a análise fractográfica todas as condições estudadas apresentaram fratura dúctil caracterizada pela formação e coalescência de microcavidades com forma e tamanhos variados / The Ti-6A-4V alloy is a biomaterial that has proved very suitable for the manufacture of prostheses to repair craniofacial injuries. Among other requirements, it is important that the prosthesis resist mechanical stress to ensure a satisfactory clinical response in order to provide comfort and safety to patients. The specific purpose of this research is to determine the influence of thermal cycles - as prototyped, 650 °C (1h); 650 °C (3h), 800 °C (2h) and 850 °C (4h) - on the microstructure and fracture micromechanisms resulting from uniaxial tension in traction. Therefore it was manufactured by DMLS technique bodies - of - proof traction which were subsequently subjected to different thermal cycles. Then, the bodies -specimens were subjected to tensile test. Microstructural characterization was carried out using optical and scanning electron microscopy (SEM). The resulting fracture surfaces of the five conditions for thermal cycling were analyzed by SEM. The final sample microstructure produced as a result of the additive manufacturing process DMLS revealed a hexagonal martensitic microstructure α '. For A6501H sample, the resulting martensitic microstructure DMLS process is not decomposed. In A6503H martensitic microstructure sample begins to decompose, as are observed precipitates of β phase. Already in the samples A8004H and A8502H observe a structure (α + β) with α and β phase crystal phase precipitated in the contours. According to fractographic analysis of all studied showed ductile fracture conditions characterized by the formation and coalescence wells with varying shape and sizes
126

Modificação de superfície empregando-se laser e recobrimento de implantes dentários de titânio com apatitas

Braga, Francisco José Corrêa [UNESP] 01 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-01Bitstream added on 2014-06-13T19:21:32Z : No. of bitstreams: 1 braga_fjc_dr_araiq.pdf: 10292078 bytes, checksum: 0f5eba7b9211550254ba580ec5d5f63d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os implantes orais em titânio e suas ligas biocompatíveis vêm nas últimas três décadas acentuando o seu aprimoramento funcional quanto às suas quatro principais propriedades esperadas: protocolo cirúrgico, projeto mecânico, sistema de acoplamento protético e tratamento de superfície. A proposta deste trabalho está focalizada nesta última propriedade. Diversos tipos de tratamento de superfície vêm atualmente sendo oferecidas ao mercado com o propósito de favorecer a catálise do fenômeno de osseointegração, o aumento de área de contato com o tecido ósseo calcificado, e resistência à corrosão pelo organismo. O processo atualmente considerado mais limpo é caracterizado pela irradiação por feixe de laser, onde a superfície do implante não sofre nenhuma interação com outro qualquer material para a sua modificação. O presente estudo correlaciona as condições paramétricas do feixe de laser Nd:YVO4 aplicado ao titânio comercialmente puro (cp) e sua liga Ti6Al4V com os tipos de topografia e compostos formados na superfície destes metais, como também com as características de adesão à camada de apatita depositada pelo método biomimético. Os métodos de análise e caracterização realizados neste estudo foram essencialmente físico-químicos como WDXRF, MEV, EDS, DRX, MFA, FTIR, Rugosimetria, Molhabilidade e Ensaio de Flexão. Palavras-chaves: biomateriais; laser; implante; titânio; apatita; biomimético. / From three decades ago to nowadays, oral implants made of metallic titanium and its biocompatible alloys had a great functional improvement referred to their four most important properties: surgical protocol, mechanical design, prosthesis/implant attachment system and surface modification processes. The scope of the present paper is focused on this last property. Several types of surface treatment in implants are offered due to the market appeal in improvements as the osteointegration process catalysis, augmentation of the bone/implant contact surface area and corrosion resistance to the organism aggression. Today, the most clean surface modification process is technological based in laser beam irradiation where the modified surface does not has contact with any tool or material to be treated. The present study correlates the laser beam parameters arrangement irradiating commercially pure metallic titanium and Ti6Al4V alloy with the resulting surface topography, the formed crystalline fases and as wel as the adhesion capacity to apatite deposition by biomimetic process. The used physical-chemistry analytical and characterization methods in this study were WDXRF, SEM, EDS, XRD, MFA, FTIR, rugosimetry, wetness and flexural mechanical test. KEY-WORDS: biomaterials; laser; implant; titanium; apatite; biomimetic.
127

Estudo das modificações na superfície do Ti cp titânio comercialmente puro e da liga Ti-6AI-4V usados como biomateriais utilizando-se deposição por plasma spray

Alencar, Anselmo Colombo de [UNESP] January 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2002Bitstream added on 2014-06-13T18:43:10Z : No. of bitstreams: 1 alencar_ac_dr_araiq.pdf: 2842903 bytes, checksum: 85256141f060542ecd98e64fda280b5b (MD5) / Este trabalho estudou-se a superfície do Ti cp e a liga metálica de Ti-6Al-4V usados como biomateriais para implantes, antes e após a modificação superficial (revestimento) empregando-se a aspersão térmica de dióxido de titânio por meio da técnica de plasma spray. A finalidade deste tratamento foi produzir um suporte funcional e quimicamente adequado possuindo grande área específica favorável para uma posterior osseointegração, o que garante uma melhor adesão do osso regenerado à superfície do implante usado para a prótese. A caracterização realizou-se usando métodos instrumentais: análise química, microscopia eletrônica, análise metalográfica, ensaios de dureza e difratometria de raios X do Ti cp, da liga, do composto de partida e do revestimento após a deposição. Conforme a microscopia eletrônica de varredura - MEV com EDS - a superfície do revestimento apresenta uma morfologia porosa e altamente homogênea. Os difratogramas de raios X do revestimento mostraram a presença de monóxido de titânio defeituoso e Ti2O3 . Na análise pontual de EDS, na região da interface, observou-se a difusão dos elementos Al e V da liga para o revestimento, e do oxigênio do revestimento para o substrato. Conclui-se que a presença de TiO e Ti2O3 na superfície está relacionada com a decomposição térmica do dióxido de titânio no jato de plasma spray com uma posterior recombinação dos seus componentes na forma de sesquióxido Ti2O3 e intercalação de oxigênio formando soluções sólidas superficiais de composição TiO1-x. A morfologia porosa e a presença destas fases no revestimento permite recomendar esta metodologia para a fixação do implante quando aplicado clinicamente. / The surface of cp Ti and Ti-6Al-4V alloy for implants was studied before and after the superficial modification (coating) using the technique of titanium dioxide spraying with plasma-gun. The purpose of such a treatment was to create functional and chemically appropriate metal support having large specific area favorable for the posterior osseointegration which will guarantee a better adhesion of the regenerated bone to the surface of the implant used for the prostheses. The characterizations have been carried out by using instrumental techniques: chemical analysis. electron microscopy, metallography, hardness tests and X rays diffraction study of cp Ti, alloy, starting oxide and coating after the deposition. According to the morphology studies performed by scanning electron microscopy, the coating surface is porous and exhibits high homogeneity. The coating X ray pattern showed the presence of both defectuous titanium monoxide and Ti2O3. Point EDS analysis of the interface region permitted to observe aluminum and vanadium diffusion from alloy to the coating and that of oxygen from the coating to substract. It is to conclude that the presence of TiO and Ti2O3 on the surface is owing to the thermal decomposition of titanium dioxide in the plasma jet spray followed by the recombination of its components in the form of Ti2O3 and oxygen insertion producing superficial solid solutions of the composition TiO1-x. The porous morphology and the presence of the above phases in the coating allows to recommend this technique for the implant fixation in clinics.
128

Avaliação, por extensometria, da deformação superficial no substrato de retenção dos implantes gerada por próteses fixas implanto suportadas em função do cantilever

Mesquita, Alfredo Mikail Melo [UNESP] 30 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-30Bitstream added on 2014-06-13T18:45:59Z : No. of bitstreams: 1 mesquita_amm_dr_sjc.pdf: 511472 bytes, checksum: bdcad35472f1cab510c82684030d9a0f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar, por extensometria, da deformação superficial ao redor de implantes em função do comprimento do cantilever de próteses implanto-suportadas por 2 ou 3 implantes. Para tanto, foram posicionados, paralelos entre si, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75mm de diâmetro por 11,5mm de comprimento, a uma distância entre eles de 8mm, de centro a centro, em um modelo experimental de poliuretano com dimensões de 10x7x2cm. Pilares protéticos tipo Multi-Unit, com 3,0mm de altura de cinta metálica foram instalados sobre os implantes. Com auxílio de um dispositivo em alumínio, foram confeccionados 16 padrões de fundição em resina acrílica; 8 com 2 implantes; e 8 com 3 implantes sobre cilindros calcináveis. Em seguida os padrões foram fundidos em liga de cobaltocromo pela técnica convencional à maçarico. Três extensômetros lineares (strain gauges) foram colados na superfície superior do bloco experimental de poliuretano tangenciando a plataforma dos implantes. Cargas de 10kg foram exercidas na barra em local eqüidistante entre os dois implantes mais próximos do cantilever, e no cantilever a uma distância de 5, 10, 15, 20 e 25mm, com auxílio de um dispositivo desenvolvido para esta finalidade. Os extensômetros conectados a um aparelho condicionador de sinais elétricos além de alimentar a corrente elétrica, amplificou e converteu o sinal gerado de analógico para digital. Para cada local de carga foram feitas três medições. Os dados obtidos foram submetidos à Análise de Variância (ANOVA) de 3 fatores, e ao teste de Tukey (p<0,05). Como conclusão do tratamento dos dados obtidos em microdeformação (με): não houve diferença da utilização de dois ou três implantes na distribuição de carga no substrato de retenção dos implantes; quanto maior a extensão do cantilever, maiores deformações foram geradas ao redor dos implantes. / The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according the cantilever length of implant-supported prosthesis by two or three implants. Sixteen polyurethane models were obtained from an acrylic block (10 x 7 x 2 cm). In half of these models two cylindrical implants with external hexagon were fixed (diameter: 3.75 mm; length: 11.5 mm) and positioned 8 mm between their centers in each model. On the other half, three parallels implants were fixed in the same conditions. The Multi-Unit abutments with 3 mm of metallic neck were connected to the implants. With the assistance of an aluminum device, it was manufacture sixteen acrylic resin patterns over the cast cylinders: eight with two implant and eight three implants. After, patterns were casted in cobalt-chromium alloy, using the casting conventional technique. Three strain gauges were positioned on the upper surface of the experimental polyurethane model around the implants. With an assistance of a device, the metallic bars were loaded with 10 Kg between the two implants near to the cantilever and 5, 10, 15, 2 and 25 mm along the cantilever length. The strain-gauge was connected to a multichannel bridge amplifier to form one leg of the bridge. The computer was interfaced with bridge amplifier to register output signs of polyurethane strain. Each point of loading was measured three times. The data were submitted to ANOVA (three-way) and Tukey test (p<0.05). The cantilever length affected negatively the load distribution around the implants around the implants (p<0.05). Such as conclusion t from the treatment of the data obtained (με): there wasn’t difference between the using of two or three implants on the stress distribution on the substrate of implants retention; how longer is the cantilever, higher stress around implants were generated.
129

Influência da deposição de filmes de carbono tipo diamante na infiltração bacteriana pela interface entre implantes e pilares protéticos

Cardoso, Mayra [UNESP] 18 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-18Bitstream added on 2014-06-13T20:45:50Z : No. of bitstreams: 1 000758225.pdf: 2964831 bytes, checksum: 9dd38178e41e4dfce4ae833a7c0c3ca4 (MD5) / O estudo avaliou a influência da deposição de filmes de DLC na infiltração bacteriana pela interface entre pilares protéticos e implantes de hexágono externo (HE) e interno (HI). Também avaliou a aderência microbiana a estes filmes, depositados sobre titânio. A deposição dos filmes foi realizada por PECVD (Deposição Química a Vapor Assistida por Plasma), e sua caracterização foi feita pelas análises de perfilometria mecânica, espectroscopia Raman, rugosidade, análise tribológica, espectroscopia de energia dispersiva e ângulo de contato. Para avaliação da aderência microbiana, lâminas de titânio (N=45; n=15) foram divididas em três grupos: (1) sem filme (controle); (2) com filme de DLC; e (3) com filme de DLC dopado com prata (DLC-Ag). Elas foram suspensas em poços contendo saliva-glicerol e caldo de cultura. Após 48 h de incubação, elas foram agitadas em ultrassom e a suspensão resultante foi diluída e semeada em placas para contagem de microrganismos. Para avaliação da infiltração bacteriana pela interface implante/pilar, conjuntos de implantes e pilares HE e HI (N=180; n=30) foram divididos de acordo com o tratamento da base do pilar: (1) nenhum tratamento (controle); (2) deposição de filme de DLC; e (3) deposição de filme de DLC-Ag. Sob condições assépticas, foi inoculado 1 μL de suspensão de Enterococcus faecalis no interior dos implantes, e os pilares foram parafusados com 20 Ncm. Os conjuntos foram testados para contaminação externa imediata, suspensos em tubos de ensaio contendo caldo de cultura estéril, e acompanhados por cinco dias. A turvação do caldo indicou infiltração bacteriana. Ao final do período, os pilares foram desparafusados e o conteúdo interno dos implantes foi coletado com cone de papel e semeado em placas de Petri. Estas foram levadas a estufa bacteriológica por 24 h para verificação da viabilidade bacteriana.... / This study evaluated the influence of DLC films on bacterial leakage through the interface between abutments and dental implants of external hexagon (HE) and internal hexagon (HI). It also evaluated microbial adhesion to these films deposited on titanium. The deposition of the films was performed by PECVD (Plasma Enhanced Chemical Vapor Deposition), and its characterizations were done by mechanical profilometry, Raman spectroscopy, surface roughness, tribological analysis, energy dispersive spectroscopy and contact angle. To evaluate the microbial adhesion, titanium blades (N=45, n=15) were divided into three groups: (1) without film (control), (2) with DLC film, and (3) with DLC film doped with silver (Ag-DLC). They were suspended in wells containing saliva-glycerol broth. After 48 h incubation they were ultrasonicated and the resulting suspension was diluted and plated for CFU counting. For evaluation of bacterial leakage through implant/abutment interface, sets of implants and abutments (N=180, n=30) were divided according to the treatment of the base of the abutment: (1) no treatment (control); (2) deposition of DLC film, and (3) deposition of Ag-DLC film. Under aseptic conditions, 1 μL of Enterococcus faecalis was inoculated inside the implants, and abutments were tightened to 20 Ncm. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed for five days. The turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper cone and seeded in Petri dishes. These were incubated for 24 h for assessment of bacterial viability and CFU counting. The roughness and log10CFU/mL data were analyzed by analysis of variance. The bacterial leakage was analyzed by Chi-square test, Fisher exact test, Kaplan-Meier and ....
130

Sobrevivênvia e sucesso de implantes osseointegrados com superfície tratada por ataque ácido: avaliação retrospectiva de 8 a 10 anos

Nícoli, Lélis Gustavo [UNESP] 24 March 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-24Bitstream added on 2014-12-02T11:21:07Z : No. of bitstreams: 1 000798064.pdf: 1338097 bytes, checksum: 4e73f39cb79767bd4dca8a67d9f1405d (MD5) / Implantes dentários com superfície tratada por ataque ácido representam uma opção clínica para a reabilitação de regiões edêntulas. No entanto, trabalhos prévios mostram que uma variedade de fatores de risco pode comprometer a longevidade do implante. O objetivo deste estudo foi avaliar retrospectivamente a taxa de sobrevivência e sucesso de implantes com superfície tratada por ataque ácido. A amostra constituiu-se de 183 implantes instalados em 44 pacientes que foram submetidos à reabilitação protética no período de 2003 a 2005. A idade média dos pacientes no momento da instalação dos implantes foi de 50 anos, sendo 18 pacientes do gênero masculino e 26 do gênero feminino. Após exames clínico e radiográfico, foi verificado que apenas 5 implantes (2,7%) foram perdidos em 4 pacientes, 1 na maxila e 4 na mandíbula, e 3 implantes (2,0%) não estavam em função. Dos implantes presentes, 155 (87%) aderiram aos critérios de sucesso e 20 (11%) apresentavam peri-implantite. Os pacientes foram reabilitados com próteses múltiplas e unitárias do tipo parafusadas ou cimentadas. Dentre as reabilitações protéticas, implantes com próteses múltiplas parafusadas apresentaram uma maior porcentagem de peri-implantite (15,3%). Baseado nestes resultados, implantes com superfície tratada com ataque ácido apresentaram uma taxa de sobrevivência de 97% e uma taxa de sucesso de 85% após um período de 8 a 10 anos em função. / Rough-surface dental implants are a viable clinical alternative for rehabilitation of edentulous areas. However, previous studies have suggested that a vast array of risk factors may compromise the long-term success rate of dental implants. This retrospective study aimed to evaluate the survival and the success rates of dental implants with an acid-etched surface. 183 implants were performed in 44 patients who received subsequent implant-supported prosthetic treatment between the years of 2003 and 2005. Patient mean-age at the time of implant placement was 50 years. 18 patients were male and 26 female. Clinical and radiographic examination showed that only 5 implants (2,7%) were lost among 4 patients, 1 in the maxilla and 4 in the mandible and that 3 implants (2,0%) were not in function. 155 (87%) of the functioning implants fell under the success criteria employed whereas 20 (11%) of them presented peri-implantitis. Rehabilitation included screw-retained or cemented single crowns and bridges. A higher prevalence of peri-implantitis (15.3%) was noted for screw-retained bridges. Results showed a survival rate of 97,3% and a success rate of 87% for dental implants with an acid-etched surface after 8 to 10 years of loading.

Page generated in 0.082 seconds