• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 851
  • 34
  • 32
  • 32
  • 31
  • 23
  • 9
  • 9
  • 9
  • 7
  • 5
  • 5
  • 3
  • 2
  • Tagged with
  • 881
  • 881
  • 560
  • 490
  • 219
  • 205
  • 156
  • 118
  • 104
  • 98
  • 87
  • 85
  • 83
  • 81
  • 76
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Implantes zigomáticos na reabilitação do sistema estomatognático

Hochheim Neto, Ricardo January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catatina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T13:44:00Z (GMT). No. of bitstreams: 1 188419.pdf: 3441391 bytes, checksum: b6dddccf6f92978c31fa50da6f336c90 (MD5) / Os implantes zigomáticos são alternativas recentemente desenvolvidas para minimização de procedimentos cirúrgicos que necessitem de grandes enxertos ósseos em maxilas extremamente atrésicas com diminuição de tempo e morbidade dos procedimentos cirúrgicos e protéticos. Duas técnicas cirúrgicas serão comparadas a técnica convencional desenvolvida pelo Dr Per Ingvar Branemark(NOBEL BIOCARE),para chegarmos a conclusões neste trabalho de dissertação
72

Mensuração do calor friccional gerado pelo preparo do tecido ósseo em implantodontia

Andriani Júnior, Wilson January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T13:51:28Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:40:00Z : No. of bitstreams: 1 182533.pdf: 3248629 bytes, checksum: df6bcf911d5984160dc71eb1f7cadfe2 (MD5) / O objetivo deste estudo in vitro foi desenvolver um dispositivo para avaliar o desempenho dos sistemas de irrigação interna e externa em implantodontia. A amostra foi composta de 20 espécimens ósseas de origem bovina. Dez espécimens foram submetidas a perfurações com as brocas do sistema 3i utilizando-se irrigação interna. Nas outras dez espécimens utilizou-se irrigação externa. Os resultados obtidos foram submetidos a tratamento estatístico. Na comparação individual das interações entre o tipo de broca e de irrigação testados, os resultados indicam que a broca 2,3 mm quando utilizada com irrigação externa provocou maior diferença de temperatura entre os momentos inicial e final , que todas as outras situações testadas. Dessa forma observou-se, neste estudo, que o sistema de irrigação interna gerou menor calor que o sistema de irrigação externa.
73

Avaliação, por extensometria, da deformação superficial no substrato de retenção dos implantes gerada por próteses fixas implanto suportadas em função do cantilever

Mesquita, Alfredo Mikail Melo [UNESP] 30 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-30Bitstream added on 2014-06-13T18:45:59Z : No. of bitstreams: 1 mesquita_amm_dr_sjc.pdf: 511472 bytes, checksum: bdcad35472f1cab510c82684030d9a0f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar, por extensometria, da deformação superficial ao redor de implantes em função do comprimento do cantilever de próteses implanto-suportadas por 2 ou 3 implantes. Para tanto, foram posicionados, paralelos entre si, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75mm de diâmetro por 11,5mm de comprimento, a uma distância entre eles de 8mm, de centro a centro, em um modelo experimental de poliuretano com dimensões de 10x7x2cm. Pilares protéticos tipo Multi-Unit, com 3,0mm de altura de cinta metálica foram instalados sobre os implantes. Com auxílio de um dispositivo em alumínio, foram confeccionados 16 padrões de fundição em resina acrílica; 8 com 2 implantes; e 8 com 3 implantes sobre cilindros calcináveis. Em seguida os padrões foram fundidos em liga de cobaltocromo pela técnica convencional à maçarico. Três extensômetros lineares (strain gauges) foram colados na superfície superior do bloco experimental de poliuretano tangenciando a plataforma dos implantes. Cargas de 10kg foram exercidas na barra em local eqüidistante entre os dois implantes mais próximos do cantilever, e no cantilever a uma distância de 5, 10, 15, 20 e 25mm, com auxílio de um dispositivo desenvolvido para esta finalidade. Os extensômetros conectados a um aparelho condicionador de sinais elétricos além de alimentar a corrente elétrica, amplificou e converteu o sinal gerado de analógico para digital. Para cada local de carga foram feitas três medições. Os dados obtidos foram submetidos à Análise de Variância (ANOVA) de 3 fatores, e ao teste de Tukey (p<0,05). Como conclusão do tratamento dos dados obtidos em microdeformação (με): não houve diferença da utilização de dois ou três implantes na distribuição de carga no substrato de retenção dos implantes; quanto maior a extensão do cantilever, maiores deformações foram geradas ao redor dos implantes. / The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according the cantilever length of implant-supported prosthesis by two or three implants. Sixteen polyurethane models were obtained from an acrylic block (10 x 7 x 2 cm). In half of these models two cylindrical implants with external hexagon were fixed (diameter: 3.75 mm; length: 11.5 mm) and positioned 8 mm between their centers in each model. On the other half, three parallels implants were fixed in the same conditions. The Multi-Unit abutments with 3 mm of metallic neck were connected to the implants. With the assistance of an aluminum device, it was manufacture sixteen acrylic resin patterns over the cast cylinders: eight with two implant and eight three implants. After, patterns were casted in cobalt-chromium alloy, using the casting conventional technique. Three strain gauges were positioned on the upper surface of the experimental polyurethane model around the implants. With an assistance of a device, the metallic bars were loaded with 10 Kg between the two implants near to the cantilever and 5, 10, 15, 2 and 25 mm along the cantilever length. The strain-gauge was connected to a multichannel bridge amplifier to form one leg of the bridge. The computer was interfaced with bridge amplifier to register output signs of polyurethane strain. Each point of loading was measured three times. The data were submitted to ANOVA (three-way) and Tukey test (p<0.05). The cantilever length affected negatively the load distribution around the implants around the implants (p<0.05). Such as conclusion t from the treatment of the data obtained (με): there wasn’t difference between the using of two or three implants on the stress distribution on the substrate of implants retention; how longer is the cantilever, higher stress around implants were generated.
74

Influência da deposição de filmes de carbono tipo diamante na infiltração bacteriana pela interface entre implantes e pilares protéticos

Cardoso, Mayra [UNESP] 18 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-18Bitstream added on 2014-06-13T20:45:50Z : No. of bitstreams: 1 000758225.pdf: 2964831 bytes, checksum: 9dd38178e41e4dfce4ae833a7c0c3ca4 (MD5) / O estudo avaliou a influência da deposição de filmes de DLC na infiltração bacteriana pela interface entre pilares protéticos e implantes de hexágono externo (HE) e interno (HI). Também avaliou a aderência microbiana a estes filmes, depositados sobre titânio. A deposição dos filmes foi realizada por PECVD (Deposição Química a Vapor Assistida por Plasma), e sua caracterização foi feita pelas análises de perfilometria mecânica, espectroscopia Raman, rugosidade, análise tribológica, espectroscopia de energia dispersiva e ângulo de contato. Para avaliação da aderência microbiana, lâminas de titânio (N=45; n=15) foram divididas em três grupos: (1) sem filme (controle); (2) com filme de DLC; e (3) com filme de DLC dopado com prata (DLC-Ag). Elas foram suspensas em poços contendo saliva-glicerol e caldo de cultura. Após 48 h de incubação, elas foram agitadas em ultrassom e a suspensão resultante foi diluída e semeada em placas para contagem de microrganismos. Para avaliação da infiltração bacteriana pela interface implante/pilar, conjuntos de implantes e pilares HE e HI (N=180; n=30) foram divididos de acordo com o tratamento da base do pilar: (1) nenhum tratamento (controle); (2) deposição de filme de DLC; e (3) deposição de filme de DLC-Ag. Sob condições assépticas, foi inoculado 1 μL de suspensão de Enterococcus faecalis no interior dos implantes, e os pilares foram parafusados com 20 Ncm. Os conjuntos foram testados para contaminação externa imediata, suspensos em tubos de ensaio contendo caldo de cultura estéril, e acompanhados por cinco dias. A turvação do caldo indicou infiltração bacteriana. Ao final do período, os pilares foram desparafusados e o conteúdo interno dos implantes foi coletado com cone de papel e semeado em placas de Petri. Estas foram levadas a estufa bacteriológica por 24 h para verificação da viabilidade bacteriana.... / This study evaluated the influence of DLC films on bacterial leakage through the interface between abutments and dental implants of external hexagon (HE) and internal hexagon (HI). It also evaluated microbial adhesion to these films deposited on titanium. The deposition of the films was performed by PECVD (Plasma Enhanced Chemical Vapor Deposition), and its characterizations were done by mechanical profilometry, Raman spectroscopy, surface roughness, tribological analysis, energy dispersive spectroscopy and contact angle. To evaluate the microbial adhesion, titanium blades (N=45, n=15) were divided into three groups: (1) without film (control), (2) with DLC film, and (3) with DLC film doped with silver (Ag-DLC). They were suspended in wells containing saliva-glycerol broth. After 48 h incubation they were ultrasonicated and the resulting suspension was diluted and plated for CFU counting. For evaluation of bacterial leakage through implant/abutment interface, sets of implants and abutments (N=180, n=30) were divided according to the treatment of the base of the abutment: (1) no treatment (control); (2) deposition of DLC film, and (3) deposition of Ag-DLC film. Under aseptic conditions, 1 μL of Enterococcus faecalis was inoculated inside the implants, and abutments were tightened to 20 Ncm. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed for five days. The turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper cone and seeded in Petri dishes. These were incubated for 24 h for assessment of bacterial viability and CFU counting. The roughness and log10CFU/mL data were analyzed by analysis of variance. The bacterial leakage was analyzed by Chi-square test, Fisher exact test, Kaplan-Meier and ....
75

Sobrevivênvia e sucesso de implantes osseointegrados com superfície tratada por ataque ácido: avaliação retrospectiva de 8 a 10 anos

Nícoli, Lélis Gustavo [UNESP] 24 March 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-24Bitstream added on 2014-12-02T11:21:07Z : No. of bitstreams: 1 000798064.pdf: 1338097 bytes, checksum: 4e73f39cb79767bd4dca8a67d9f1405d (MD5) / Implantes dentários com superfície tratada por ataque ácido representam uma opção clínica para a reabilitação de regiões edêntulas. No entanto, trabalhos prévios mostram que uma variedade de fatores de risco pode comprometer a longevidade do implante. O objetivo deste estudo foi avaliar retrospectivamente a taxa de sobrevivência e sucesso de implantes com superfície tratada por ataque ácido. A amostra constituiu-se de 183 implantes instalados em 44 pacientes que foram submetidos à reabilitação protética no período de 2003 a 2005. A idade média dos pacientes no momento da instalação dos implantes foi de 50 anos, sendo 18 pacientes do gênero masculino e 26 do gênero feminino. Após exames clínico e radiográfico, foi verificado que apenas 5 implantes (2,7%) foram perdidos em 4 pacientes, 1 na maxila e 4 na mandíbula, e 3 implantes (2,0%) não estavam em função. Dos implantes presentes, 155 (87%) aderiram aos critérios de sucesso e 20 (11%) apresentavam peri-implantite. Os pacientes foram reabilitados com próteses múltiplas e unitárias do tipo parafusadas ou cimentadas. Dentre as reabilitações protéticas, implantes com próteses múltiplas parafusadas apresentaram uma maior porcentagem de peri-implantite (15,3%). Baseado nestes resultados, implantes com superfície tratada com ataque ácido apresentaram uma taxa de sobrevivência de 97% e uma taxa de sucesso de 85% após um período de 8 a 10 anos em função. / Rough-surface dental implants are a viable clinical alternative for rehabilitation of edentulous areas. However, previous studies have suggested that a vast array of risk factors may compromise the long-term success rate of dental implants. This retrospective study aimed to evaluate the survival and the success rates of dental implants with an acid-etched surface. 183 implants were performed in 44 patients who received subsequent implant-supported prosthetic treatment between the years of 2003 and 2005. Patient mean-age at the time of implant placement was 50 years. 18 patients were male and 26 female. Clinical and radiographic examination showed that only 5 implants (2,7%) were lost among 4 patients, 1 in the maxilla and 4 in the mandible and that 3 implants (2,0%) were not in function. 155 (87%) of the functioning implants fell under the success criteria employed whereas 20 (11%) of them presented peri-implantitis. Rehabilitation included screw-retained or cemented single crowns and bridges. A higher prevalence of peri-implantitis (15.3%) was noted for screw-retained bridges. Results showed a survival rate of 97,3% and a success rate of 87% for dental implants with an acid-etched surface after 8 to 10 years of loading.
76

Efeito de três sistemas de osteotomia - ultrassom cirúrgico, laser Er, Cr: YSGG e sistema rotatório - sobre o processo de osseointegração e reparo de defeitos ósseos em tíbia de ratos: estudo histomorfométrico, imuno-histoquímico e biomecânico

Esteves, Jônatas Caldeira [UNESP] 14 March 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-14Bitstream added on 2015-01-26T13:30:19Z : No. of bitstreams: 1 000805961_20170314.pdf: 349223 bytes, checksum: 448acffc1a9c58492a9b1e664b17feac (MD5) Bitstreams deleted on 2017-03-17T12:38:10Z: 000805961_20170314.pdf,. Added 1 bitstream(s) on 2017-03-17T12:39:09Z : No. of bitstreams: 1 000805961.pdf: 4843456 bytes, checksum: f128a369968d68e92229dadbd28be7df (MD5) / O objetivo deste trabalho foi avaliar o processo de reparo ósseo e a osseointegração de implantes inseridos em leitos cirúrgicos preparados por meio de Brocas Convencionais, Ultrassom Piezoelétrico e LASER Er,Cr:YSGG. Como objetivo secundário, foi testada a habilidade do ultrassom cirúrgico de estumilar a liberação de citocinas e fatores de crescimento ósseo durante o processo de reparo. Para tanto, dois estudos distintos foram conduzidos. No Estudo 1, 144 ratos foram divididos em 3 grupos (Grupos Broca, LASER e Piezo) com 48 animais cada. Mini implantes usinados foram instalados em ambas as tíbias de cada animal em alvéolos cirúrgicos preparados pelos 3 sistemas testados de acordo com o grupo ao qual o animal pertencia Após a intervenção cirúrgica, 8 animais por grupo foram sacrificados aos 0, 3, 7, 14, 30 e 60 dias pós-operatórios.. O implante da tíbia direita foi utilizado para o ensaio de torque de remoção e o da tíbia esquerda, para análise de Contato-Osso-Implante (COI) e Fração de Área Ocupada por Osso (FAOO). No Estudo 2, 174 animais foram divididos nos mesmos grupos experimentais – Broca, Piezo e Laser – com 63, 63 e 48 animais cada, respectivamente. Defeitos ósseos de 2mm de diâmetro foram produzidos na tíbia direita dos animais usando um dos três dispositivos testados de acordo com o grupo ao qual o animal foi designado. Oito animais de cada grupo foram sacrificados aos 0, 3, 7, 14 30 e 60 dias e a cicatrização óssea foi analisada por histomorfometria e detecção imuno-histoquímica de Osteocalcina, Osteoprotegerina, Rankl, Vegf e Caspase-3. Cinco animais dos Grupos Broca e Piezo foram sacrificados aos 3, 7 e 14 dias e o espécimes coletados foram utilizados para análise de PCR quantitativo (Q-PCR). Os resultados do Estudo 1 demonstraram a osseointegração dos implantes no três grupos estudados. No Grupo Broca a formação óssea ocorreu mais precocemente, porém um aumento significativo no... / The aim of this study was to evaluate the bone healing process and osseointegration of implants placed in sockets prepared by conventional Drills, Piezosurgery and Er,Cr:YSGG laser. As a secondary objective we tested the hability of Piezosurgery of enhancing the bone repair by releasing of citokynes and growth factor. Therefore, two different studies were conducted. In study 1, 144 rats were assigned to 3 groups: Groups Drill, Laser and Piezo, with 48 animals in each group. Machined mini-implants were placed in both tibiae of each animal in sockets prepared by the three tested systems, according to the group in which it was assigned. After the surgical procedures, 8 animals were sacrificed postoperatively at 0, 3, 7, 14, 30 and 60 days in each group. The implant of the right tibia was used for removal torque test and the left tibia implant was used for Bone-to-Implant Contact (BIC) and Bone Area Fraction Occupancy (BAFO) analysis. In Study 2, 174 animals were ssigned to the same experimental Goups - Drill, Piezo and Laser – with 63, 63 and 48 animals in each group. Bone defects with 2mm in diameter were created in the righ tibia of each animal using one of the three tested devices according to the group in which it was assigned. Eight animals of each group was sacrificed at 0, 3, 7, 14 , 30 and 60 days and bone healing were analyzed by means of histomorphometry and immunohistochemical detection of Osteocalcin, Osteoprotegerin, Rankl, Vegf and Caspase-3. Also, 5 animals form Gorups Drill and Piezo were sacrificed at 3, 7 and 14 days and the bone samples were used for quantitative PCR (Q-PCR) analysis. Results of Study 1 demonstrated implant osseointegration in all experimental groups. The Group Drill presented early bone formation, however, significant increasing in torque removal values occurred only at 30 days. In Groups Laser and Piezo, removal torque increased early and bone healing around the implant was progressively increased until...
77

Plataforma regular versus switching : estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e interno /

Freitas Júnior, Amilcar Chagas. January 2011 (has links)
Orientador: Eduardo Passos Rocha / Banca: Wirley Gonçalves Assunção / Banca: Idelmo Rangel Garcia Júnior / Banca: Paulo Guilherme Coelho / Banca: Paulo Francisco César / Resumo: Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below) / Doutor
78

Efeito da teriparatida (PTH 1-34) no reparo ósseo periimplantar em ratos submetidos à orquiectomia /

Ferreira, Pedro Henrique Silva Gomes. January 2017 (has links)
Orientador: Roberta Okamoto / Coorientador: Leonardo Perez Faverani / Banca: Idelmo Rangel Garcia Junior / Banca: Clóvis Marzola / Resumo: Objetivos: Avaliar a morfometria e dinâmica óssea periimplantar em ratos submetidos à orquiectomia, tratados com teriparatida. Materiais e Métodos: 18 ratos foram divididos em 3 grupos: SHAM - cirurgia fictícia, ORQ - orquiectomia, e ORQTERI - orquiectomia bilateral, tratados com teriparatida. Cada animal recebeu um implante na metáfise tibial. Aos 14 e 42 dias de pós-operatório, foram administrados os fluorocromos calceína e alizarina, respectivamente. A eutanásia ocorreu ao 60 dias após a instalação dos implantes. As peças foram analisadas na microtomografia computadorizada (microCT) para avaliação dos parâmetros de volume e percentual de volume ósseo (BV, BV/TV), espessura do trabeculado (Tb.Th), número e separação de trabéculas (Tb.N, Tb.Sp) e percentual de porosidade total, (Po-tot). Para microscopia confocal a laser, a mensuração da área dos fluorocromos, da taxa diária de aposição mineral (MAR), da extensão linear de contato osso/implante (ELCOI) e área de osso neoformado (AON), foi realizada no programa Image J. Os dados não paramétricos foram comparados pelo teste Kruskal-Wallis e paramétricos pelo teste ANOVA 1 ou 2 fatores. Como pós-teste, os testes de Holm-Sidak, ou Tukey foram aplicados, com nível de significância a 5%. Resultados: Para os parâmetros BV, BV/TV, Tb.Th, o grupo ORQTERI apresentou os maiores valores em relação aos demais grupos e, para Po-tot, os menores valores foram para o grupo ORQTERI (ORQ: p<0,05 e SHAM: p>0,05). Para Tb.Sp o grupo SHAM apres... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objectives: To evaluate morphometry and peri-implant bone dynamics in rats submitted to orchiectomy, treated with teriparatide. Materials and Methods: 18 rats were divided into 3 groups: SHAM - fictitious surgery, ORQ - orchiectomy, and ORQTERI - bilateral orchiectomy, treated with teriparatide. Each animal received an implant in the tibial metaphysis. At the 14 and 42 postoperative days, calcein and alizarin were administered, respectively. Euthanasia occurred 60 days after implant installation. The pieces were analyzed by computerized microtomography (microCT) for evaluation of volume and percentage of bone volume (BV, BV/TV), trabecular thickness (Tb.Th), number and separation of trabeculae (Tb.N, Tb.Sp) and percentage of total porosity, (Po-tot). For laser confocal microscopy, the area of the fluorochromes, the mineral apposition rate (MAR), the linear bone implant contact (ELCOI) and the newly formed bone area (AON) were measured in Image J. The nonparametric data were compared by the Kruskal-Wallis test and parametric by the ANOVA 1 or 2 factor test. As a post-test, the Holm-Sidak or Tukey tests were applied, with significance level at 5%. Results: For the parameters BV, BV/TV, Tb.Th, the ORQTERI group presented the highest values in relation to the other groups and, for Po-tot, the lowest values were for the ORQTERI group (ORQ: p <0.05 and SHAM: p> 0.05). For !27 Tb.Sp the SHAM group presented the best result (ORQ: p<0.05 and ORQTERI: p>0.05), and Tb.N, there was no statistically significant difference in the comparison of intragroup results (p>0.05). For MAR and fluorochemical evaluation, ORQTERI showed better peri-implantar bone turnover (ORQ: p <0.05), for ELCOI and AON, the SHAM group presented the highest results (ORQ: p <0.05). Conclusions: Treatment with Teriparatide improves bone dynamics, in addition to increasing the volume and quality of peri-implant bone / Mestre
79

Avaliação da manutenção óssea em implantes instalados a partir da abordagem trimodal: acompanhamento de 1-4 anos

Sczepanik, Fábio Sá Carneiro January 2015 (has links)
Made available in DSpace on 2015-05-29T12:51:02Z (GMT). No. of bitstreams: 1 000469538-Texto+Completo-0.pdf: 1770446 bytes, checksum: 90b8e8696e775e37ea2dd8f6aec011bc (MD5) Previous issue date: 2015 / Purpose : The purpose of this retrospective investigation was to evaluate, radiographically and clinically, a group of patients treated with immediate single-tooth placement, immediate restoration implants with a customized definitive abutment with a flapless approach in the area between both maxillary canines. Marginal bone level (MBL) and marginal bone level of neighboring teeth (MBLN) were assessed.Methods : A sample of 20 subjects received 20 tapered platform-switching implants using a minimally invasive surgery (trimodal approach). The mean age was 55. 2 years (range 25 - 71 years), and the mean follow-up period was 2. 2 years (range 12 - 48 months).Results : The overall treatment survival was 100%. There was no statistically significant difference between MBLN in both mesial and distal aspects, comparing baseline to final follow-up and between the four radiographs independently (i. e. , at baseline, at 06 months, at 12 months, and at final follow-up). There was a statistically significant difference between MBL in both mesial and distal aspects at baseline and at final follow-up (p<0. 05).Conclusion : Within the limitations of this study, it has demonstrated that the trimodal approach might offer an advantage in terms of marginal bone levels, especially in MBLN, in a mean follow-up time of 26 months. Additionally, reduced overall treatment time, one surgical intervention, and immediate esthetics can be obtained with 100% survival and success rates using a minimally invasive approach. / Objetivos : O objetivo desta investigação retrospectiva foi avaliar, radiograficamente e clinicamente, um grupo de pacientes tratados com instalação imediata de implantes unitários, provisório imediato com um pilar protético personalizado, com uma abordagem sem descolamento de retalho mucoperiostal na região ântero superior. Nível da crista óssea marginal e crista óssea marginal a nível dos dentes adjacentes foram avaliados.Materiais e métodos : Uma amostra de 20 indivíduos recebeu 20 implantes cônicos com mudança de plataforma através de uma abordagem minimamente invasiva (abordagem trimodal). A média de idade foi de 55,2 anos (variando de 25 a 71 anos) e o período médio de acompanhamento foi de 2,2 anos (variando de 12 a 48 meses).Resultados : A taxa total de sobrevivência dos implantes e coroas definitivas foi de 100%. Não houve diferença estatisticamente significativa entre MBLN nas faces mesial e distal, comparando-se baseline ao controle final, assim como não houve entre as quatro radiografias independentemente (i. e. baseline, 6 meses, 12 meses e controle final). Houve diferença estatisticamente significativa entre MBL nas faces mesial e distal entre baseline e o controle final (p<0,05).Conclusão : Dentro das limitações deste estudo, demonstramos que a abordagem trimodal pode oferecer uma vantagem em termos de níveis de crista óssea marginal, especialmente em MBLN, durante um período médio de acompanhamento de 26 meses. Adicionalmente, reduzido tempo total de tratamento, apenas uma etapa cirúrgica e estética imediata podem ser obtidos com 100% de taxas de sobrevivência e sucesso, utilizando uma abordagem minimamente invasiva.
80

Estudo das microdeformações geradas ao redor de implantes de hexágono interno com roscas convencionais e implantes com platôs, sob a aplicação de carga vertical /

Santos, Vivian Mayumi Miyazaki. January 2013 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Eduardo Shigueyuki Uemura / Banca: Luis Gustavo de Oliveira Vasconcellos / Resumo: O objetivo deste estudo foi avaliar a micro deformação ao redor de implantes hexágono interno e implantes com roscas platô sob carregamento vertical. Foram confeccionados 10 blocos de poliuretano com 190X30X12 mm. Na face de menor largura e maior comprimento de cada bloco foi inserido um implante de cada sistema (implante hexágono interno de 4 mm X 8,5 mm e implante platô de 4,5 mm X 8 mm) que depois receberam um pilar com 10 mm de altura. O pilar do implante hexágono interno recebeu torque de 20 N com auxilio de torquímetro manual, enquanto o pilar do implante platô foi inserido no implante com o auxilio de martelete. Quatro extensômetros foram colados ao redor dos implantes. Também foram colados extensômetros na lateral do bloco na região do terço médio e apical dos implantes. Os implantes foram submetidos a uma carga vertical estática de 30 Kg. Os dados foram submetidos a análise estatística ANOVA e Tukey (5%). Foi verificado que houve diferença estatística significante para a região cervical (horizontal) dos implantes em relação à região média e apical (vertical), sendo o P=0.0259. Com o teste Tukey, foi verificado que a região horizontal dos implantes platôs apresentaram uma maior micro deformação em relação a região vertical e da região horizontal e vertical dos implantes hexágono interno. Pode-se concluir que o implante platô demonstrou maior micro deformação do que o implante hexágono interno, a região cervical obteve uma maior concentração de tensões em relação à região do terço médio e apical e que o tipo de conexão pilar/implante interfere na micro deformação distribuída ao redor do implante / Abstract: The aim of the study was to evaluate the micro strain around internal hexagon implant and plateau screws implant under vertical load. 10 polyurethane blocks were produce with 190X30X12 mm. On the narrower face of each block was inserted in each system implant (internal hexagon implant 4 mm X 8,5 mm and plateau implant 4,5 mm X 8 mm) which then received one abutment with 10 mm high. The internal hexagon abutment received torque of 20 N with aid manual torquemeter and plateau abutment was inserted with surgical mallet. Four strain gauge were bonded around of the implants. Also the strain gauges were bonded in the lateral block in the middle and apical region implants. The implants were subjected to a static vertical load of 30 kg. The data were submitted to ANOVA and Tukey (5%). It was found that there was statistically significant difference for the cervical region (horizontal) of the implants to the middle and apical region (vertical), with P = 0.0259. In the Tukey test, it was found that the horizontal region of the plateau implants was higher micro strain than vertical region of the plateau implants and horizontal and vertical region of the internal hexagon implants. It concluded that the implant had a higher plateau micro strain of the implant internal hexagon, the cervical region showed a higher stress concentration towards the region of the middle and apical, and the connection type abutment/implant interferes with micro strain distributed around the implant / Mestre

Page generated in 0.0906 seconds