Spelling suggestions: "subject:"implantes dentários"" "subject:"aimplantes dentários""
91 |
Influencia de diferentes superficies de implantes endosseos de titanio sobre o processo de osseintegração : analises histologica e histemetrica em tibia de coelhosCortez, Andre Luis Vieira 03 August 2018 (has links)
Orientador: Jose Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T05:45:35Z (GMT). No. of bitstreams: 1
Cortez_AndreLuisVieira_M.pdf: 11134343 bytes, checksum: 8b0190a31a9eb9c7df9866709b0d8481 (MD5)
Previous issue date: 2002 / Mestrado
|
92 |
Efeito do estrogeno e da calcitonina sobre o reparo e densidade ossea ao redor de implantes de titanio inseridos em ratas ovariectomizadasDuarte, Poliana Mendes 04 February 2003 (has links)
Orientador : Francisco Humberto Nociti Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T08:19:23Z (GMT). No. of bitstreams: 1
Duarte_PolianaMendes_M.pdf: 3070725 bytes, checksum: 184f3c24f30630c6e7026d2feed39536 (MD5)
Previous issue date: 2003 / Resumo: o objetivo desse estudo foi avaliar a influência do estrógeno (E) e da calcitonina (CT) sobre o reparo e densidade óssea ao redor de implantes inseridos em ratas ovariectomizadas (OVX). Cinqüenta e oito animais foram divididos aleatoriamente em quatro grupos experimentais: Grupo 1 (n=15): ovariectomia simulada; Grupo 2 (n=15): ovariectomia; Grupo 3 (n=14): OVX e administração subcutânea de CT, 4 dias por semana (16 IU/Kg), um dia após OVX durante todo período experimental; Grupo 4 (n=14): OVX e administração diária de 1713 estradiol (20Jl9/Kg) um dia após
OVX durante todo período experimental. Vinte e um dias após a ovariectomia bilateral, cada animal recebeu um implante de titânio rosqueável por tíbia. Após sessenta dias da colocação dos implantes os animais foram sacrificados e obtidas secçóes não-descalcificadas. Os parâmetros histométricos
analisados foram: densidade óssea (DO) numa região de 500 Jlm lateral ao implante, contato direto osso-implante (CD) e área óssea dentro das roscas (AO). Os resultados foram obtidos e avaliados separadamente na região cortical (zona A) e medular (zona B). Na zona A, a análise intergrupo não demonstrou diferenças estatisticamente significantes para o CD e DO (P>0.05). Em contraste, o grupo 4 demonstrou maior área óssea que os grupos 2 e 3 (P<0.05). Resultados obtidos da zona B revelaram que o estrógeno anulou o efeito negativo da ovariectomia na DO, CD e AO (P<O.05),
enquanto a calcitonina não apresentou o mesmo efeito (P>0.05). Dentro dos limites desse estudo, conclui-se que a administração diária de estrógeno pode prevenir a influência negativa da deficiência do estrógeno endógeno no reparo e densidade óssea ao redor de implantes de titânio / Abstract: This study evaluated whether estrogen (E) and calcitonin (CT) administration could influence bone healing and bone density around implants placed in ovariectomized rats (OVX). Twenty-one days betore implant placement, bilateral ovariectomies were performed trom a dorsal approach. One screw-shaped titanium implant was placed bilaterally. The animais were assigned to one of the tollowing groups: Group 1 (n=15): sham surgeries; Group 2 (n=15): OVX rats; Group 3 (n=14): OVX rats subcutaneously administered with calcitonin (CT) 4 days/week (16 IU/Kg); Group 4 (n=14): OVX rats subcutaneously administered with 1713 estradiol daily (20Jlg/Kg). After sixty days, the animais were sacrificed and undecalcified sections obtained. Bone density (8D) (the proportion of mineralized bone in a 500 Jlm-wide zone lateral to the implant), bone-to-implant contact (B/C) and bone area (BA) around the implants were obtained and arranged separately for the cortical (Zone A) and cancellous(Zone B). In Zone A, intergroup analysis revealed no significant difference regarding BIC and BD (P>0.05). In contrast, the group 4 presented a greater bone area than groups 2 and 3 (P<0.05). Data trem Zone B revealed that estrogen nullified the negative effect of the ovariectomy on BD, BIC and BA (P<0.05), while CT presented no effect (P>O.05). Therefore, E-therapy may prevent the influence that endogenous estrogen deficiency exerts on bone healing and bane density around titanium implants / Mestrado / Periodontia / Mestre em Clínica Odontológica
|
93 |
Avaliação do tecido ósseo perimplantar através de técnicas radiográficas convencional e digitaisCavalcanti de Abreu, Taciana January 2003 (has links)
Made available in DSpace on 2014-06-12T23:00:25Z (GMT). No. of bitstreams: 2
arquivo8523_1.pdf: 966776 bytes, checksum: 1f6dee000ca6f5abb903ac7a64f7b9da (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2003 / O presente estudo examinou 48 regiões perimplantares de 12 implantes dentários de pacientes
que procuraram um serviço especializado. Os pacientes foram radiografados imediatamente
após a instalação dos implantes, 15 dias e 3 meses após a sua colocação e 3 meses após Todas as radiografias foram realizadas de maneira padronizada. Quatro sítios foram avaliados
em cada implante, dois na mesial e dois distal, sendo um na cervical e outro longo do
implante, em cada um dos lados. As seguintes análises radiográficas foram realizadas: análise
visual convencional no negatoscópio e análises digitais utilizando os programas Photoshop
6.0 (Adobe Systems Incorporated, Mountain View, California, USA) (análise quantitativa dos
níveis de cinza) e o ImageTool 2.0 (University of Texas Health Science Center, San Antonio,
Texas, USA) (subtração digital). Com base na metodologia empregada e nos resultados
encontrados foi possível concluir que: a) o tempo utilizado não foram suficientes para
demonstrar a presença de osteointegração em torno dos implantes dentários; b) as técnicas de
análise digitais não puderam detectar osteointegração em menor tempo, quando comparadas à
técnica subjetiva de análise visual convencional, nos períodos de tempo avaliados; c) os
fenômenos de reabsorção óssea predominaram, principalmente na região cervical do implante;
d) a avaliação no negatoscópio e a subtração digital demonstraram que os processos de
reabsorção óssea predominam na região cervical do implante, 3 meses após a colocação dos
mesmos, enquanto a mensuração dos NC não demonstrou diferença nos resultados obtidos
nos dois tempos cirúrgicos avaliados; e) os fenômenos de reabsorção foram mais evidentes na
mandíbula, e os de neoformação óssea na maxila; f) a mensuração dos NC com ponto de corte
5 comportou-se diferentemente da mesma análise com ponto de corte 10, assim como a
análise no negatoscópio e a subtração digital, e a subtração digital e a mensuração dos NC
com ponto de corte de 5; g) em relação aos testes de diagnóstico, a avaliação no negatoscópio,
tendo-se como padrão-ouro a análise dos NC, com ponto de corte 5 ou 10, foi a que
apresentou maior acurácia; e os piores resultados ocorreram quando o negatoscópio foi
considerado o padrão-ouro em relação aos demais
|
94 |
Analise fotoelastica da distribuição de tensões em implantes cilindricos rosqueados com hexagono externo e internoMeirelles, Luiz Augusto Duarte 16 June 2003 (has links)
Orientador : Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:10:15Z (GMT). No. of bitstreams: 1
Meirelles_LuizAugustoDuarte_M.pdf: 2064072 bytes, checksum: 38b14046d2439ff6fc794b7affc652c2 (MD5)
Previous issue date: 2003 / Resumo: Este estudo analisou a distribuição de tensões pela simulação de esforços mastigatórios em tomo a implantes dentários cilíndricos rosqueados com hexágono externo e interno. Foram recortados blocos de policarbonato PSM-l (Photolastic mc. Realeigh, USA) com dimensões de 35 x 25 x 6,1 mm, nos quais foram instalados os implantes dentários. Foram utilizados dois implantes de 3,75 de diâmetro e 10,0 mm de comprimento com hexágono externo e interno (Master Screw e Master Conect AR, Conexão Sistemas de Prótese, São Paulo, Brasil). O carregamento de 10 kgF foi aplicado por um dispositivo mecânico acoplado a uma célula de carga com 15° de inclinação em relação ao implante. Cada implante foi levado individualmente ao polariscópio circular para a visualização e interpretação das franjas fotoelásticas, obtendo-se valores numéricos que correspondem à ordem de franja para cada ponto traçado em tomo do implante sobre a imagem obtida. Foi possível observar padrões de distribuição de tensões distintos quanto à região entre os implantes. O implante com hexágono externo apresentou valores maiores na primeira rosca e na região cervical, enquanto o implante com hexágono interno apresentou valores maiores na região apical do implante. Nas demais regiões os valores encontrados foram similares / Abstract: This study analyzed the stress distribution around cylindrical screwed implants with external and internal hexagon simulating occlusion load. Blocks of PSM-1 (Photolastic mc., Realeigh, USA) were milled with dimensions of 35 x 25 x 6,1 mm where the implants were installed. Implants with diameter of 3.75 mm and high of 10.0 mm with external and internal hexagon (Master Screw and Master Conect AR, Conexão Sistemas de Prótese, São Paulo, Brasil). Load was applied with a mechanical device with a load cell with 15 degrees. Each implants were taken separately to a circular polariscope for the observation and interpretation of the photoelastic fringes. Numerical values of the fringe order were obtained for each point marked around the implants images. It was possible to verify different patterns of stress distribution regarding the area and intensity between the implants under 10 kgF load. Highest values was observed in the implant with external hexagon at the cervical area and at the first screw and in the implant with internal hexagon at the apex of the implant. The remaining areas presented similar values / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
95 |
Implantes de titânio com superfície tratada a base de β-tricálcio fosfato em levantamento da membrana sinusal. Estudo experimental de superfície, análise biomecânica, histométrica e imunoistoquímica em coelhos /Corrêa, Ana Paula Simões. January 2018 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Coorientador Francisley Ávila Souza / Banca: Ana Paula Farnezi Bassi / Banca: Thallita Pereira Queiroz / Banca: Rodrigo dos Santos Pereira / Resumo: Modificações físicas e/ou químicas das superfícies dos implantes de titânio podem ser realizadas com intuito de facilitar e estimular o processo de osseointegração, consequentemente favorecendo um tempo de reparo mais curto. Sendo assim, o objetivo deste estudo foi avaliar as superfícies de implantes de titânio, modificadas com deposição de β-tricálcio fosfato pelo método biomimético, inseridos na maxila após levantamento de seio maxilar de coelhos, por meio da análise topográfica, biomecânica, microtomográfica, histológica e imunoistoquímica. Dezoitos (18) coelhos da raça Nova Zelândia (Albinus) receberam trinta e seis (36) implantes após elevação da membrana do seio maxilar bilateral. Foram divididos em dois grupos: No Grupo SBF - Implantes com superfícies modificadas pelo tratamento biomimético e preenchimento do seio maxilar esquerdo com coágulo; Grupo TCP - Implantes com superfícies modificadas com deposição de β-tricálcio fosfato pelo método biomimético e preenchimento do seio maxilar direito com coágulo. Os períodos de estudos foram de 7, 15 e 40 dias, onde foram realizadas as avaliações biomecânica, microtomográfica, histométrica e imunoistoquímica. Nas análises físico-químicas de microscopia eletrônica de varredura- MEV, espectroscopia de energia dispersiva- EDS e mapeamento da mineralização observou-se a formação de uma camada de apatita com maiores quantidades de Ca e P nos implantes com deposição biomimética com β-tricálcio fosfato. O teste de molhabilidade monstr... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Physical and/or chemical modifications of the surfaces of the titanium implants can be performed in order to facilitate and stimulate the osseointegration process, consequently favouring a shorter repair time. Thus, the objective of this study was to evaluate the surfaces of titanium implants, modified with deposition of β-tricalcium phosphate by the biomimetic method, inserted in the maxilla after lifting the maxillary sinus of rabbits, employing topographic, biomechanical, histological and immunohistochemical analysis. Eighteen (18) New Zealand rabbits (Albinus) received thirty-six (36) implants after bilateral maxillary sinus membrane elevation. They were divided into two groups: In the SBF Group - Implants with surfaces modified by the biomimetic treatment and filling of the left maxillary sinus with clot; Group TCP - Implants with modified surfaces with deposition of β-tricalcium phosphate by the biomimetic method and filling of the right maxillary sinus with clot. The study periods were 7, 15 and 40 days, where the biomechanical, microtomographic, histometric and immunohistochemical evaluations were performed. In the physico-chemical analyzes of scanning electron microscopy (SEM), dispersive energy spectroscopy (EDS) and mapping of mineralization, the formation of an apatite layer with higher amounts of Ca and P was observed in implants with biomimetic deposition with β-tricalcium phosphate. The wettability test showed high hydrophilicity surfaces in this group of impla... (Complete abstract click electronic access below) / Doutor
|
96 |
Acompanhamento longitudinal do sucesso das próteses suportadas por implantes osseointegrados do sistema NAPIO / Longitudinal follow-up of NAPIO osseointegrated implants in function for 2 yearsSylvia Maria Bastos Correia 14 December 1999 (has links)
Nos últimos anos, têm sido possível a reposição de dentes ausentes, utilizando-se os implantes osseointegrados como suporte para próteses. A eficácia clínica desta terapia por implantes foi bem estabelecida por uma miríade de trabalhos longitudinais com alto índice de sucesso e suprindo critérios previamente estabelecidos. Nestes estudos, observou-se concentração das falhas desde a segunda cirurgia até o primeiro ano de instalação da prótese. Para a realização deste estudo foi avaliado o sucesso de implantes do sistema NAPIO (Núcleo de Apoio à Pesquisa de Implantes Odontológicos) confeccionados em titânio grau I e previamente tratados por ataque ácido. Foram inseridos 371 implantes em 109 pacientes suportando 135 próteses unitárias, parciais, protocolo e sobre-dentaduras, durante 2 anos. A distribuição por sexo foi de 39.4% de homens e 60.6% de mulheres com idade variando de 17 a 82 anos. Os implante foram avaliados clinicamente através da profundidade de sondagem, nível de inserção, presença de placa, edema, supuração, alteração na coloração e radiograficamente pela técnica do cone longo padronizando a posição com o registro da mordida em resina acrílica. Os implantes foram classificados como sucesso se suprissem os critérios de SMITH; ZARB186. O índice de sucesso na maxila foi de 90.21% e 99.25% e na mandíbula de 95.90% e de 100%, respectivamente, para os implantes e as próteses, compatível com os relatados na literatura. Detectou-se concentração das falhas até a segunda fase cirúrgica, com mais de 75% destas localizadas na maxila e superior a 55% na mandíbula. Todos os implantes que falharam apresentaram comprimento igual ou inferior a 10 mm. As radiografias foram digitalizadas e medidas no programa Sigma Scan Pro, obtendo-se a perda óssea de 0.95 na face mesial, 1.03 na face distal e a média de 0.99 durante dois anos. A inflamação do tecido peri-implantar, presença de placa e sangramento a sondagem reduziram significativamente nos quatro exames. A medida de profundidade de sondagem e nível de inserção também diminuíram, porém de forma insignificante. A complicação, mais freqüente, da prótese foi o reaperto do parafuso da prótese, seguida da fratura deste. Os pacientes aferiram notas subjetivas, em relação ao conforto, estética e função da prótese suportada por implantes e a média das notas foi sempre superior a 9 na maxila e mandíbula. A partir dos dados obtidos com parâmetros periodontais, percentual de sucesso e falha, perda óssea mensurada radiograficamente, como também das complicações das próteses, concluiu-se que existe compatibilidade com os dados da literatura atestando a efetividade do sistema de implantes avaliado durante os dois primeiros anos . / Replace of missing teeth by osseointegrated implants has become an accepted treatment modality in clinical dentistry. The clinical efficacy of implant therapy has been demonstrated through a myriad of long-term studies following an established criteria for success and showing high survival rates. In those studies most of the failures were concentrated at the second stage surgery and in the first year following the insertion of the prostheses. In the present study , the success of 371 implants of the NAPIO (Center of Supporting Research in Dental Implants) implant system placed in function for 2 years were evaluated. These implants were used to support 135 single units and a variety of fixed and removable prothesis placed in 109 patients presenting partial and complete edentulism. The gender distribution encompassed 43% of males and 66% of females. The age range was between 17 and 82 years old. The implants were made of titanium grade I and acid etched. Clinical and radiografic evaluation were done every 6 months in the first year and then once a year for 2 years. The clinical evaluation was performed using several known periodontal parameters such as, probing depth, attachment level, presence of plaque, suppuration, edema and color alteration. For radiographic assessment, a standardized technique using an individually customized film holder with acrylic resin was used. The implants were evaluated using the success criteria described by SMITH; ZARB186. The success index for the mandible was 95.90% and for the maxilla 90.21% reflecting a clinical efficacy similar to others osseointegrated implant systems. Of the failing implants, 77% of those placed in the maxilla and 45.5% of the ones placed in the mandible were detected at second surgery, and were all of short length. The radiographs were digitized and measured using the software Sigma Scan Pro 4 (Jandel Scientifics) and the bone loss calculated for every time point. Results demonstrated an overall bone loss of 0.99 mm during 2 years. There were very little changes in probing depth and attachment level during the first 2 years and, almost no changes were found using parameters to access inflammation of the peri-implant tissue, presence of plaque, edema and bleeding on probing. The most frequent complication found in the prostheses assessment was loosening and fracturing of the retaining screw. The grades of confort, esthetics and function of the prostheses were assessed by the patients and the results were superior to 9.4 attesting the efficacy of the treatment from the patients point of view. It was concluded that the results found for clinical parameters, implants success, bone loss measured radiografically and complications found in the prosthesis during the first two years of follow-up were in agreement with results presented in the literature for other osseointegrated implant systems.
|
97 |
Comparação das avaliações histológica, clínica e por meio de exames de imagens da qualidade óssea da região maxilomandibular para a instalação de implantes dentários /Oliveira, Marina Reis. January 2017 (has links)
Orientador: Valfrido Antonio Pereira Filho / Resumo: O presente trabalho teve como objetivo avaliar a qualidade óssea das diferentes regiões alveolares da maxila e da mandíbula por meio da classificação óssea proposta por Leckholm e Zarb (1985) (L & Z), radiografias panorâmicas e periapicais, quociente de estabilidade do implante (ISQ), torque de inserção (TI), microtomografia computadorizada (micro-CT) e histomorfometria. Como objetivo secundário, foi avaliada a correlação entre os diversos métodos citados acima. Foram avaliadas 60 áreas edêntulas, sendo 15 áreas de cada quadrante da maxila e da mandíbula. A qualidade óssea tipo III foi a mais frequente na maxila posterior (73,33%) e anterior (73,33%), já a tipo II foi mais frequente na mandíbula posterior (53,33%) e anterior (60,00%). Foi observada uma diferença estatisticamente significante na densidade óssea óptica avaliada por meio de radiografias periapicais na região posterior da maxila (2,38±1,06) e posterior da mandíbula (3,84±0,68), em relação às demais regiões alveolares avaliadas (p≤0,015). Nas radiografias panorâmicas não foram observadas diferenças entre a densidade óptica das regiões alveolares (p=0,6322). A estabilidade inicial dos implantes instalados na região posterior da maxila foi estatisticamente diferente dos instalados na região posterior da mandíbula, tanto na avaliação por meio do TI como por meio do ISQ (p<0,05). Também foi possível detectar diferenças na qualidade óssea das regiões alveolares da maxila e da mandíbula por meio de vários parâmetros da ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate the bone quality of the different alveolar regions of the maxilla and mandible through of the classification proposed by Leckholm e Zarb (1985) (L & Z), panoramic and periapical radiographs, implant stability quotient (ISQ), insertion torque (IT), microcomputed tomography (micro-CT) and histomorphometric analysis. The secondary objective was to evaluate the correlation between the several methods mentioned above. Sixty edentulous areas were evaluated, being 15 areas from each quadrant of the maxilla and mandible. The bone quality III was the most frequent in the posterior (73.33%) and anterior maxilla (73.33%) and quality II was the most frequent in the posterior (53.33%) and anterior (60.00%) mandible. A significant statistical difference was observed in the optical bone density evaluated through periapical radiographs of the posterior maxilla (2.38 ± 1.06) and posterior mandible (3.84 ± 0.68), in relation to the other alveolar regions (p≤0.015). With the panoramic radiograph no differences were observed between the optical density of the alveolar regions (p= 0.6322). The primary stability of the implants in the posterior maxilla was different from the posterior mandible, both in the evaluation through the TI and ISQ (p<0.05). It was possible to detect differences in the bone quality of the alveolar regions using several micro-CT parameters (BV, p≤0.002; BV/BT, p≤0.044; BS/TV, p <0.05; Tb.N, p<0.01 and Tb.Sp, p <0.05). With the histometry it was ... (Complete abstract click electronic access below) / Doutor
|
98 |
Avaliação da osseointegração de uma superfície hidrofílica em osso do tipo IV : estudo pré-clínico em ilíacos de coelhos /Pinto, Gustavo Da Col dos Santos January 2019 (has links)
Orientador: Elcio Marcantonio Jr / Resumo: O objetivo desse estudo foi avaliar a osseointegração de uma superfície hidrofílica (Jateamento + ataque ácido + imersão em solução isotônica) em comparação a uma superfície hidrofóbica (Jateamento + ataque ácido), utilizando um modelo experimental de osso tipo IV, obtido através da instalação de implantes de titânio no osso ilíaco de coelhos. Para realização do estudo, 24 animais foram submetidos a instalação de 4 implantes no osso ilíaco bilateralmente, sendo 2 implantes com superfície hidrofóbica e dois implantes com superfície hidrofílica. Os coelhos foram submetidos à eutanásia nos períodos de 2, 4 e 8 semanas após a instalação dos implantes. Após a eutanásia, um implante de cada superfície foi utilizado para execução da análise de torque de remoção. Enquanto isso, o outro implante foi utilizado para execução de cortes histológicos não-descalcificados e para avaliação do contato direto entre o osso e a superfície do implante (%BIC) e da fração de área de tecido ósseo entre as roscas dos implantes (%BBT). Os implantes com superfície hidrofílica apresentaram maiores valores de torque de remoção no período de 8 semanas (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) e maiores valores de %BIC (42.92 ± 2.85 % vs. 29.49 ± 10.27 %) e de %BBT (34.32 ± 8.52 % vs. 23.20 ± 6.75 %) do que os implantes com superfície hidrofóbica no período experimental de 2 semanas. Implantes com superfície hidrofílica apresentaram aceleração no processo de osseointegração, que culmina em uma maior estab... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
|
99 |
Acompanhamento longitudinal do sucesso das próteses suportadas por implantes osseointegrados do sistema NAPIO / Longitudinal follow-up of NAPIO osseointegrated implants in function for 2 yearsCorreia, Sylvia Maria Bastos 14 December 1999 (has links)
Nos últimos anos, têm sido possível a reposição de dentes ausentes, utilizando-se os implantes osseointegrados como suporte para próteses. A eficácia clínica desta terapia por implantes foi bem estabelecida por uma miríade de trabalhos longitudinais com alto índice de sucesso e suprindo critérios previamente estabelecidos. Nestes estudos, observou-se concentração das falhas desde a segunda cirurgia até o primeiro ano de instalação da prótese. Para a realização deste estudo foi avaliado o sucesso de implantes do sistema NAPIO (Núcleo de Apoio à Pesquisa de Implantes Odontológicos) confeccionados em titânio grau I e previamente tratados por ataque ácido. Foram inseridos 371 implantes em 109 pacientes suportando 135 próteses unitárias, parciais, protocolo e sobre-dentaduras, durante 2 anos. A distribuição por sexo foi de 39.4% de homens e 60.6% de mulheres com idade variando de 17 a 82 anos. Os implante foram avaliados clinicamente através da profundidade de sondagem, nível de inserção, presença de placa, edema, supuração, alteração na coloração e radiograficamente pela técnica do cone longo padronizando a posição com o registro da mordida em resina acrílica. Os implantes foram classificados como sucesso se suprissem os critérios de SMITH; ZARB186. O índice de sucesso na maxila foi de 90.21% e 99.25% e na mandíbula de 95.90% e de 100%, respectivamente, para os implantes e as próteses, compatível com os relatados na literatura. Detectou-se concentração das falhas até a segunda fase cirúrgica, com mais de 75% destas localizadas na maxila e superior a 55% na mandíbula. Todos os implantes que falharam apresentaram comprimento igual ou inferior a 10 mm. As radiografias foram digitalizadas e medidas no programa Sigma Scan Pro, obtendo-se a perda óssea de 0.95 na face mesial, 1.03 na face distal e a média de 0.99 durante dois anos. A inflamação do tecido peri-implantar, presença de placa e sangramento a sondagem reduziram significativamente nos quatro exames. A medida de profundidade de sondagem e nível de inserção também diminuíram, porém de forma insignificante. A complicação, mais freqüente, da prótese foi o reaperto do parafuso da prótese, seguida da fratura deste. Os pacientes aferiram notas subjetivas, em relação ao conforto, estética e função da prótese suportada por implantes e a média das notas foi sempre superior a 9 na maxila e mandíbula. A partir dos dados obtidos com parâmetros periodontais, percentual de sucesso e falha, perda óssea mensurada radiograficamente, como também das complicações das próteses, concluiu-se que existe compatibilidade com os dados da literatura atestando a efetividade do sistema de implantes avaliado durante os dois primeiros anos . / Replace of missing teeth by osseointegrated implants has become an accepted treatment modality in clinical dentistry. The clinical efficacy of implant therapy has been demonstrated through a myriad of long-term studies following an established criteria for success and showing high survival rates. In those studies most of the failures were concentrated at the second stage surgery and in the first year following the insertion of the prostheses. In the present study , the success of 371 implants of the NAPIO (Center of Supporting Research in Dental Implants) implant system placed in function for 2 years were evaluated. These implants were used to support 135 single units and a variety of fixed and removable prothesis placed in 109 patients presenting partial and complete edentulism. The gender distribution encompassed 43% of males and 66% of females. The age range was between 17 and 82 years old. The implants were made of titanium grade I and acid etched. Clinical and radiografic evaluation were done every 6 months in the first year and then once a year for 2 years. The clinical evaluation was performed using several known periodontal parameters such as, probing depth, attachment level, presence of plaque, suppuration, edema and color alteration. For radiographic assessment, a standardized technique using an individually customized film holder with acrylic resin was used. The implants were evaluated using the success criteria described by SMITH; ZARB186. The success index for the mandible was 95.90% and for the maxilla 90.21% reflecting a clinical efficacy similar to others osseointegrated implant systems. Of the failing implants, 77% of those placed in the maxilla and 45.5% of the ones placed in the mandible were detected at second surgery, and were all of short length. The radiographs were digitized and measured using the software Sigma Scan Pro 4 (Jandel Scientifics) and the bone loss calculated for every time point. Results demonstrated an overall bone loss of 0.99 mm during 2 years. There were very little changes in probing depth and attachment level during the first 2 years and, almost no changes were found using parameters to access inflammation of the peri-implant tissue, presence of plaque, edema and bleeding on probing. The most frequent complication found in the prostheses assessment was loosening and fracturing of the retaining screw. The grades of confort, esthetics and function of the prostheses were assessed by the patients and the results were superior to 9.4 attesting the efficacy of the treatment from the patients point of view. It was concluded that the results found for clinical parameters, implants success, bone loss measured radiografically and complications found in the prosthesis during the first two years of follow-up were in agreement with results presented in the literature for other osseointegrated implant systems.
|
100 |
Avaliação da Taxa de Sobrevivência e da Condição Periimplantar em Pacientes Periodontalmente Comprometidos: Estudo Transversal de Implantes em Função Por um Período de 10 a 18 AnosLOPES, G. D. R. S. 08 August 2017 (has links)
Made available in DSpace on 2018-08-01T23:26:01Z (GMT). No. of bitstreams: 1
tese_11180_Dissertacao Mestrado Versão Impressão Guilherme Scalzer.pdf: 635625 bytes, checksum: de6fa8a651fa5a86a4368f93e4daea62 (MD5)
Previous issue date: 2017-08-08 / Apesar da alta taxa de sobrevivência dos implantes dentários, a região peri-implantar pode apresentar quadros inflamatórios conhecidos como mucosite peri-implantar, que quando não tratados podem evoluir para peri-implantite. Ambas as patologias são inflamações induzidas pelo biofilme de maneira similar a etiopatogenia das doenças periodontais. O objetivo do estudo foi avaliar a taxa de sobrevivência e o perfil peri-implantar em indivíduos com histórico de doença periodontal, pois eles poderiam ser mais suscetíveis às doenças inflamatórias peri-implantares. Sendo assim, o presente estudo avaliou, clínica e radiograficamente, 58 implantes instalados em sete indivíduos, tratados por uma mesma equipe de profissionais, em uma clínica privada da cidade de Vitória/ES, entre os anos de 1997 e 2005, de modo que no momento da coleta de dados todos os implantes apresentavam pelo menos 10 anos em função. Foram avaliadas as seguintes variáveis relacionadas aos implantes: índice de placa visível (IPV), índice de sangramento gengival marginal (ISGM), profundidade de sondagem peri-implantar (PSP), sangramento à sondagem peri-implantar (SSP) e nível ósseo marginal (NOM), a fim de relacioná-las à sobrevivência e à classificação dos implantes. Os resultados mostraram um índice de sobrevivência de 100% e a classificação dos 58 implantes se deu da seguinte forma: 11 (18,9%) foram classificados como saudáveis e 12 (20,7%) como clinicamente estáveis. Os outros 35 implantes (60,4%) apresentaram algum tipo de inflamação peri-implantar, sendo 20 deles (34,5%) diagnosticados com mucosite e 15 (25,9%) com peri-implantite. Dentre as variáveis estudadas, diferenças estatisticamente significativas foram observadas somente para a localização do implante (p<0,01) e para o índice de sangramento gengival marginal (ISGM) (p=0,03). A maioria dos implantes instalados em maxila (85,7%) foram classificados com algum tipo de inflamação peri-implantar (mucosite ou peri-implantite). Para os implantes que apresentaram escore 1 para o ISGM a maioria (75,0%) também foi classificada com algum tipo de inflamação peri-implantar (mucosite ou peri-implantite). O estudo demostrou que implantes instalados em pacientes periodontalmente comprometidos podem apresentar altas taxas de sobrevivência em longo prazo. Porém, apesar dessa alta taxa de sobrevivência, a maioria dos implantes foi classificada com algum tipo de inflamação peri-implantar.
|
Page generated in 0.0923 seconds