• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 79
  • 79
  • 79
  • 37
  • 32
  • 20
  • 20
  • 14
  • 12
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado: análise pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] 11 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-11Bitstream added on 2014-06-13T19:44:51Z : No. of bitstreams: 1 verri_fr_dr_araca.pdf: 1853726 bytes, checksum: 578403c1602d78c980bb821e076ea43c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models.
72

Influência do formato do rebordo na associação de uma prótese parcial removível de extremidade livre mandibular associada ao implante com sistema de retenção ERA, pelo método dos elementos finitos

Lucas, Liliana Vicente Melo de [UNESP] 18 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-18Bitstream added on 2014-06-13T20:06:14Z : No. of bitstreams: 1 lucas_lvm_dr_araca.pdf: 2722998 bytes, checksum: 4598b84f7bad6e641b9c428ccef728d3 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Associação das próteses parciais removíveis de extremidade livre com os implantes osseointegrados é, ainda, uma opção de tratamento pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão e o deslocamento nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm com sistema ERA de retenção, em diferentes formatos de rebordo alveolar. Para tanto, foram criados oito modelos, os quais, em corte sagital, representam: Modelo A (MA) - uma hemiarcada com rebordo horizontal, sem suporte posterior, com a presença do dente 33 e de uma PPREL convencional, com apoio metálico na incisal do dente 33, em substituição aos dentes 34, 35, 36 e 37; Modelo B (MB) - semelhante ao MA, diferenciando-se deste pela presença de um implante de 3,75 x 10,00 mm com sistema ERA de retenção associado, na região posterior da base da PPREL; Modelo C (MC) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação ascendente distal; Modelo D (MD) - semelhante ao MC, diferenciando-se deste pela presença do implante com sistema de retenção associado; Modelo E (ME) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação descendente distal; Modelo F (MF) - semelhante ao ME, diferenciando-se deste pela presença do implante com sistema ERA de retenção; Modelo G (MG) - semelhante ao MA, entretanto o rebordo distal apresenta formato descendente-ascendente; Modelo H (MH) - semelhante ao MG, diferenciando-se deste pela presença do implante com sistema ERA de retenção. Com o auxílio do programa de elementos finitos ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N, em cada ponta de cúspide.... / The association of mandibular distal extension removable artial dentures with an osteointegrated implant is a treatmeat hasn't been fully explored by modern rehabilitation dentistry yet. For this reason, the objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension and the displacement on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. For that purpose, eight models were created, representing, from a sagittal perspective: Model A (MA) - a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) - similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) - similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) - similar to ME, but different in the sense that there is an implant with an associated ERA retention system; Model G (MG) - similar to MA, however with a distally descending-ascending ridge format; Model H (MH) - similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip...(Complete abstract, click electronic address below)
73

Reparo em osso irradiado utilizando enxerto ósseo autógeno associado a plasma rico em plaquetas: análise histomorfométrica em coelhos

Scartezini, Guilherme Romano 17 December 2008 (has links)
The aim of this study was to observe the repair in irradiated bone using autogenous bone graft associated with platelet-rich plasma in rabbit model. Twelve New Zealand White rabbits were divided into two equal groups: irradiated (I) and non-irradiated (II), which were divided into subgroups: control (left tibiae) and PRP (right tibiae). The irradiated group received a single dose of 15 Gy in the tibiae bone. After forty-five days, in groups I and II, were created lesions in the tibiae, with trephine of 5 mm of diameter. The lesions were filled with autogenous bone grafts with PRP (test group) or without PRP (control group). After four weeks, the animals were sacrificed and the grafted regions were removed, fixed in formalin in PBS, demineralized in EDTA and embedded in paraffin. The histological images were captured at 4X magnification and submitted to the process of Targeting Interactive, as recommended by Oliveira et al. (2006). The region of bone matrix was called Region of Interest (ROI) and the percentage of matrix by area was obtained and analyzed through algorithms developed in the programming environment Scilab. The data were processed using the tests Kolmogrorov-Smirnov and paired ttest student and not paired. The statistical analysis of irradiated and nonirradiated groups showed no significant difference between test and control groups. Also, there s no significant difference between groups irradiated and non-irradiated. According to data obtained, the use of autogenous bone grafts associated with the PRP did not contribute significantly in the repair of irradiated bone. / O objetivo deste estudo foi analisar histologicamente, o reparo ósseo em lesões de tíbia previamente irradiada, após tratamento com enxerto ósseo autógeno associado ao PRP. Neste estudo, foram utilizados 12 coelhos separados em dois grupos iguais: irradiado (I) e não irradiado (II), que foram divididos em subgrupos: controle (tíbia esquerda) e PRP (tíbia direita). O grupo irradiado recebeu dose única de 15 Gy nas tíbias. Após 45 dias, nos grupos I e II, foram criadas lesões nas tíbias, com trefina de 5 mm de diâmetro. As lesões foram preenchidas com enxerto autógeno associado a PRP (grupo teste) ou não associado a PRP (grupo controle). Após quatro semanas, os animais foram sacrificados e as regiões enxertadas foram removidas, fixadas em formol tamponado, desmineralizadas em EDTA e processadas para inclusão em parafina. As imagens histológicas foram digitalizadas, utilizando objetiva de 4X, e submetidas ao processo de segmentação interativa, como preconizado por Oliveira et al. (2006). A região de matriz óssea foi denominada de Região de Interesse (ROI) e a porcentagem de matriz por área foi obtida e analisada por meio de algoritmos desenvolvidos em ambiente de programação SCILAB. Os dados foram tratados utilizando os testes Kolmogrorov Smirnov e Teste t de Student pareado e não pareado. Nos grupo irradiado e não irradiado a análise estatística não mostrou diferença significativa entre os subgrupos teste e controle. Também não foi observada diferença significativa entre os grupos irradiado e não irradiado. De acordo com os dados obtidos, a utilização de enxerto autógeno associado ao PRP não contribuiu, significativamente no reparo de lesões em osso irradiado. / Mestre em Odontologia
74

Análise biomecânica de implantes odontológicos / Biomechanical Analysis of Dental Implants

Silva, Naiara Cristina da 09 March 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / It was objectified in this dissertation to analyze the distribution of the stress and displacements in the bone-implant interface, using the finite element method. The implants had been analyzed in two distinct situations: put directly in the two bone layers, cortical and trabecular, simulating the situation of immediate load, previous to osseointegration, and with the implants involved by a denser bone layer simulating the occurrence of the osseointegration. The geometry of the bone layers was obtained by means of computerized cat scan and the format of the implants and the prosthetic components had been supplied by the Neodent (Curitiba, Brazil). The variables analysed had been: geometry of the implants (cylindrical and taper), abutment (internal hexagon and morse taper) and the positioning of the implants in relation to the alveolar bone boards (buccaly and palatine). With this, 16 groups of analysis were formed, for which bidimensional models of the alveolus of extration of an upper central incisor had been constructed, simultaneously with the geometry of the implants, for the numerical simulation. The results of bigger relevance had been: the Von Mises stresses, principal stress (maximum and minimum) and the shear stresses, as well as the relative displacements presented by the bone-implant structure. Through the analyses, one concluded that different implant geometries adjust themselves better to each situation (immediate load and osseointegrated implant), and that the Titamax CM implant, of cylindrical format with prosthetic connection, morse taper, in palatine position was the one that best adapted itself. The found values can lead to a better understanding of the biomechanics around the implants. Despite of being a preliminary study, the work supplies subsidies for the accomplishment of future researches, since the methodology used can be applied in a variety of similar cases found in the Implantology. / Objetivou-se nesta dissertação analisar a distribuição das tensões e deslocamentos na interface osso-implante, utilizando o método dos elementos finitos. Os implantes foram analisados em duas situações distintas: assentados diretamente nas duas camadas ósseas, cortical e trabecular, simulando a situação de carga imediata, anterior a osseointegração; e com os implantes envolvidos por uma camada óssea mais densa simulando a ocorrência da osseointegração. A geometria das camadas ósseas foi obtida por meio de tomografia computadorizada. O formato dos implantes e componentes protéticos foram fornecidos pela Neodent (Curitiba, Brasil). As variáveis analisadas foram: geometria dos implantes (cilíndrico e cônico), pilar (hexágono interno e cone morse) e o posicionamento dos implantes em relação às tábuas ósseas alveolares (vestibularizado e palatinizado). Com isto formou-se 16 grupos de análise, para os quais foram construídos modelos bidimensionais do alvéolo de extração de um incisivo central superior, conjuntamente com as geometrias dos implantes, para a simulação numérica. Os resultados de maior relevância foram: as tensões de Von Mises, tensões principais (máximas e mínimas) e as tensões cisalhantes, bem como os deslocamentos relativos apresentados pela estrutura osso-implante. Por meio das análises concluiu-se que, diferentes geometrias de implantes se ajustam melhor a cada situação (carga imediata e implante osseointegrado), e que o implante Titamax CM, de formato cilíndrico com conexão protética cone morse posicionado palatinizado, foi o que melhor adaptou-se. Os valores encontrados podem levar a um melhor entendimento da biomecânica ao redor dos implantes. Apesar de ser um estudo preliminar, o trabalho realizado fornece subsidio para a realização de pesquisas futuras, pois a metodologia utilizada pode ser empregada em uma variedade de casos similares encontrados na implantodontia. / Mestre em Engenharia Mecânica
75

Impacto do número de implantes empregados em protocolos mandibulares - Revisão sistemática

Lima, Lívia Bonjardim 07 February 2017 (has links)
Objetivo: Avaliar pacientes reabilitados com prótese tipo protocolo mandibular e analisar o impacto do diferente número de implantes utilizados na taxa de sobrevivência dos implantes, perda óssea marginal e sobrevivência das próteses. Material e métodos: Esta revisão sistemática foi conduzida segundo orientações do PRISMA e registrada sob número de registo CRD42016048523 (PROSPERO). A base de dados electrônica PubMed/MEDLINE foi pesquisada para artigos publicados até 17 de julho de 2016 sem restrições quanto ao ano de publicação e teve como objetivo responder a seguinte pergunta em formato PICO: "Em pacientes desdentados, protocolos mandibulares suportados por três implantes, comparados com diferente número de implantes, mostram taxa de sobrevivência de implantes, perda óssea marginal e sobrevivência da prótese satisfatórios?" Os estudos foram avaliados segundo os níveis de evidência OCEBM e a qualidade metodológica foi avaliada de acordo com a escala MINORS e ferramenta de risco de viés Cochrane. Foi realizada a estatística descritiva quando aplicável. Curvas de sobrevivência para os implantes foram construídas com o metódo de Kaplan Meyer e a perda óssea marginal foi analisada pelos testes de kruskal-Wallis, Dunn’s e Mann Whitney. Resultados: 21 estudos foram incluídos na síntese quantitativa. 4712 implantes e 1245 protocolos mandibulares foram examinados em 1245 pacientes. Os resultados foram agrupados em categorias com base no número de implantes instalados em cada paciente: grupo 1 (três implantes) mostrou uma taxa de sobrevivência do implante de 90%, grupo 2 (4 implantes) apresentou 95% e o grupo 3 (cinco implantes) atingiu a menor taxa de sobrevivência do implante (74%). Os grupos 1 e 3 apresentaram os menores valores de perda óssea no primeiro ano (0,73 e 0,70 mm respectivamente), com diferença estatisticamente significante do grupo 2 que registrou mediana = 1,31 mm (p = < 0,001). Conclusão: Apesar das limitações quanto à falta de estudos de elevado nível de evidência e da própria metodologia da pesquisa por termos MeSH, pôde-se concluir que protocolos mandibulares suportados por três implantes demonstraram sobrevivência de implantes e perda óssea marginal no primeiro ano satisfatórios. A sobrevivência de próteses, no entanto, foi inferior aos demais grupos e isto sugere um maior acompanhamento de tais reabilitações a fim de esclarecer dados e buscar soluções. / Purpose: To assess edentulous patients rehabilitated by implant-supported mandibular full-arch bridges and to analyze the impact of the different number of implants used on implant survival rate, bone loss around the fixtures and prosthesis survival rate. Material and methods: This systematic review followed PRISMA guidelines and was registered on PROSPERO (registration number CRD42016048523). PubMed/MEDLINE electronic database was searched for articles published up until July 17th, 2016 without restrictions about publication year and aimed to answer the following question in PICO format: “In edentulous patients, full arch-bridges supported by three implants, compared to those with different number of implants, show satisfactory implant survival rate, bone loss and prosthesis survival rate?” Evidence level of studies were evaluated according to OCEBM e the methodological quality by MINORS scale and Cochrane Risk of Bias Tool. Descriptive statistics was performed when applicable. Implant survival curves were constructed with Kaplan-meyer method and marginal bone loss was analyzed with kruskal-Wallis, Dunn’s and Mann Whitney tests. Results: 21 studies were enrolled. Overall, 4712 implants and 1245 implant-supported fullarch bridges were examined in 1245 patients. Results were grouped on categories based on the number of fixtures on each patient: Group 1 (three implants) showed an implant survival rate of 90%, Group 2 (four implants) presented 95% and the Group 3 (five implants) reached the lowest implant survival rate (74%). Group 1 and Group 3 showed the lowest values of first year bone loss (0.73 and 0.70 mm respectively), statistically significant different of Group 2 that registered median = 1,31mm (p = <0.001). Conclusion: Despite of the limitations regarding the lack of high level of evidence studies and the methodology of MeSH terms research itself, it was concluded that full archbridges supported by three implants show satisfactory implant survival rate and first year bone loss. The prosthesis survival rate, however, was inferior to the other groups and this suggests a bigger follow-up of these rehabilitations with the aim of clarifying data and search for solutions. / Dissertação (Mestrado)
76

Analise fotoelastica da distribuição de tensões em dois sistemas de proteses mandibulares sobre implantes : barra distal e solda a laser / Photoelastic analysis of the distribution of the tensions in two systems of mandibular prosthesis over implants : distal bar and laser welding

Salles, Angelo Emilio Barroso de 12 August 2018 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T16:14:35Z (GMT). No. of bitstreams: 1 Salles_AngeloEmilioBarrosode_M.pdf: 10746117 bytes, checksum: 7a6d08147fb33c8d235cc7df5f8be032 (MD5) Previous issue date: 2008 / Resumo: Este estudo avaliou por meio de análise fotoelástica, a distribuição in vitro das tensões geradas na interface "osso/implante" em próteses mandibulares, tipo protocolo, comparando duas técnicas de confecção: Solda a laser e Barra Distal (Neodent, Curitiba - PR) onde não se utiliza infra-estrutura metálica. Foram confeccionadas duas próteses com design similares (uma para cada técnica), sobre uma matriz metálica simulando um arco mandibular edêntulo, onde foram instaladas cinco réplicas de implantes de corpo único (GT- Neodent, Curitiba - PR). A partir de um molde de silicone de duplicação (Silibor - Clássico Artigos Odontológicos Ltda.) foi confeccionado um modelo em resina fotoelástica (Araldite GY279BR - Araltec Produtos Químicos Ltda. Guarulhos - SP) com cinco implantes GT (Neodent, Curitiba - PR) incorporados. Após a instalação de cada prótese sobre o modelo fotoelástico, utilizando 10 N/cm para aperto dos parafusos, foi realizada análise fotoelástica. Em seguida, foi aplicada carga oclusal de 100 N em toda extensão de cada prótese, com auxílio de uma placa metálica posicionada sobre a face oclusal dos dentes, e então realizada nova análise das tensões. Estas análises foram executadas com o auxílio de um polariscópio circular acoplado a uma máquina fotográfica digital (H1 - Sony, Japão), que permitiu a visualização das franjas e registrou através de fotografias digitais o comportamento das mesmas ao redor dos implantes no modelo fotoelástico. De acordo com os resultados, concluiu-se que a técnica utilizando Barra Distal distribuiu melhor, e transmitiu com menos intensidade, após o aperto dos parafusos, as tensões geradas na interface "osso/implantes" do que a técnica utilizando solda a laser. No entanto, ocorreu o inverso após o carregamento oclusal. / Abstract: The aim of this study was to evaluate through photoelastic analysis, the in vitro distribution of the generated tensions in the "bone/ implant" interface in mandibular prostheses, protocol type, comparing two different working techniques: the idealized by Branemark and Distal Bar (Neodent, Curitiba - PR) where framework is not used. Two similar prostheses were made (one for each technique), on a metal matrix simulating an edentulous mandible, where five replications of single body implant were installed (GT-Neodent, Curitiba - PR). From a silicone mold for duplication (Silibor - Classico Artigos Odontológicos Ltda.), a model in photoelastic resin was created (Araldite GY279BR - Araltec Produtos Quimicos Ltda., Guarulhos - SP) with five GT implants (Neodent, Curitiba - PR) embedded. After the installation of each prosthesis on the photoelastic model, using 10 N/cm for tightening the screws, a photoelastic analysis was performed. Then a 100 N occlusion load was applied throughout each prosthesis extension with the help of a metal plate positioned on the occlusal face of the teeth, and then a new analysis of the tensions was conducted. These analyses were performed with the help of a circular polariscope attached to a digital camera (H1 - Sony, Japan), which allowed the visualization of the fringes and recorded by digital photos the behaviour of the implants. According to the results, it was concluded that the Distal Bar technique distributed better, and transmitted with less intensity, after the tightening of the screws, the generated tensions to the system "bone/implants" than the laser welding. However, it happened the opposite after the occlusal load. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
77

Anomalias craniofaciais, genetica e saude publica : contribuições para o reconhecimento da situação atual da assistencia no Sistema Unico de Saude

Monlleo, Isabella Lopes 28 April 2004 (has links)
Orientador: Vera Lucia Gil da Silva Lopes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-03T22:55:58Z (GMT). No. of bitstreams: 1 Monlleo_IsabellaLopes_M.pdf: 586069 bytes, checksum: 706db2a35c57b9e799229264653c4708 (MD5) Previous issue date: 2004 / Resumo: As anomalias craniofaciais estão entre os defeitos congênitos humanos mais freqüentes e demandam assistência multiprofissional, integral e especializada, cujo custo é elevado. O médico geneticista destaca-se na equipe por ter habilidades para a caracterização etiológica e nosológica dessas condições, fundamentais para o aconselhamento genético e a correta obtenção de dados epidemiológicos. Todavia, o acesso ao tratamento ainda é precário em muitas nações, motivo pelo qual a Organização Mundial de Saúde vem estimulando pesquisas sobre oferta de serviços e qualidade da assistência prestada. Além disso, é reconhecido que a ampla variação da qualidade e dos custos da assistência estão relacionados às características estruturais e funcionais dos serviços. A primeira iniciativa para atenção a portadores de Anomalias Craniofaciais no Sistema Único de Saúde do Brasil ocorreu em 1993. Com a criação da Rede de Referência no Tratamento de Deformidades Craniofaciais, o atendimento foi ampliado, contando atualmente com 29 centros credenciados. Até o momento, esses centros não foram caracterizados. Os objetivos deste trabalho foram avaliar a organização dessa Rede, descrever a estrutura e funcionamento dos centros que a integram e verificar a oferta e o acesso à genética clínica nesses locais. Para coleta dos dados, foi utilizado um questionário semi-estruturado, remetido por correio. Os resultados demonstram agregação de centros no Sudeste, em universidades e na área de fissuras labiopalatais, com atendimento de rotina em cerca de 90% deles. A denominação da rede de assistência não parece corresponder à sua atual abrangência. As equipes estão constituídas de acordo com critérios americanos em 14 e, com europeus, em cinco centros participantes do estudo. Há geneticistas clínicos em 13 centros. Dentre esses, 61,8% contam com apenas um especialista dessa área. Apesar da baixa inserção do geneticista, em 22 centros, pais e pacientes solicitam informações sobre etiologia e prevenção que são fornecidas em 80,0% dos centros; todavia em 55% deles essa atividade é realizada por médicos não geneticistas e outros integrantes da equipe. Em conclusão, os dados sugerem a necessidade de revisão da definição, objetivos, abrangência e critérios de credenciamento dos centros de atendimento e caracterizam a precariedade da oferta e do acesso à genética clínica na Rede de Referência no Tratamento de Deformidades Craniofaciais / Abstract: Craniofacial anomalies are one of the most common birth defects in man, which have considerable medical costs in view of the long, specialized and complex treatment. The presence of the Clinical Geneticist on the team is important for clinical and etiologic characterization of these anomalies, genetic counseling and epidemiologic register. As the access for treatment is not easy in many countries, the World Health Organization launched a project for research availability and quality of the specialized services. Previous research demonstrates that variation of costs and quality of the services were related with theirs structural and functional characteristics, as well. The first initiative for public craniofacial anomalies health care in Brazil was in 1993. An important improvement occurred with the creation of the Net for Craniofacial Deformities Treatment, which is composed by 29 centers. Until now, these centers had not been studied before. The aims of this study were to evaluate the Net for Craniofacial Deformities Treatment, to describe the structural and functional characteristics of these centers and the access for genetic evaluation and genetic counseling for individuals and families in them. Data were collected by a questionnaire mailed for all these centers. The results showed an increased of centers in Southeast and in universities. Cleft lip and palate is the main clinical condition treated. Routine attendance occurred in 90% of the centers. Teams¿ composition is similar to American criteria in 14 of the centers and to European, in 5. The denomination of this assistance net does not seem in accordance to its actual activities. Clinical geneticist was present in 13 centers and 61,8% had one professional. In spite of few Clinical Geneticists in the composition of the teams, in 22 centers of attendance patients and parents asked for etiology and prevention, which have been done in 80% of them. These informations are transmitted by a non-specialized physicians and others members of the team in 55% of the centers. These data suggested that it would be necessary the revision of definition, goals, activities and standards for inclusion of the craniofacial centers. They also demonstrated that the availability and the access for clinical geneticist is not enough in the Net for Craniofacial Deformities Treatment of Brazil / Mestrado / Genetica Medica / Mestre em Ciências Médicas
78

Efeito do plasma rico em plaquetas na regeneração ossea guiada de defeitos osseos peri-implantares : estudo histometrico em cães / Effect of the platelet-rich plasma on guided bone regeneration of peri-implant bone defects: histometric study in dogs

Gurgel, Bruno Cesar de Vasconcelos 30 May 2005 (has links)
Orientadores: Marcio Zaffalon Casati, Antonio Wilson Sallum / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T19:00:36Z (GMT). No. of bitstreams: 1 Gurgel_BrunoCesardeVasconcelos_D.pdf: 2894613 bytes, checksum: b68eb32e96e2245f94ae9bfdc771987e (MD5) Previous issue date: 2005 / Resumo: O objetivo do presente estudo foi avaliar histometricamente o reparo ósseo obtido após a utilização do plasmarico em plaquetas (PRP) e/ou de membranas não reabsorvíveis no tratamentode defeitos ósseos peri-implantares, do tipo deiscência, criados cirurgicamente em cães. Foram utilizados 1O cães adultos, machos, sem raça definida, nos quais os pré-molares inferiores (P2,P3, P4)e o primeiro molar foram extraídos. Após 3 meses das extrações, os leitosparaos implantes foram criados e posteriormente 2 deiscências ósseas vestibulares bilaterais, sendo então inseridos 4 implantes dentais de titânio. As deiscências foram designadas aleatoriamente às seguintes modalidades terapêuticas: 1) controle; 2) ROG; 3)PRP;4) PRP + ROG. Após 3 meses do tratamento, os animais foram sacrificados e os blocos contendo os implantes e tecidos duros adjacentes processados para secções não descalcificadas. Na análise histométrica, os parâmetros avaliados foram o contato osso-implante, a área de preenchimento ósseo dentro das roscas, a área e a densidade de tecido ósseo formado na região fora das roscas. Análise deVariância foi utilizada para a análise estatística dos dados (p<O,O5). Os resultados demonstraram diferenças estatísticas significativas para todos os parâmetros analisados em favor dos grupos tratados commembrana (p<O,O5), no entanto, não foram observadas diferenças quando o PRP foi utilizado (p>O,O5). Dentro dos limites do presente estudo, pôde-se concluir ue o PRP não exerce efeitos adicionais no reparo ósseo e que a ROG promove uma maior formação óssea ao redor dos implantes dentais / Abstract: The aim of the present study was to evaluate, histometrically, the bone healing after utilizing the platelet-rich plasma (PRP) and/ornon-resorbable membranes on the treatment of peri-implant bone defects, deiscense type, surgically created in dogs. Ten mongrel male adult dogswere used; in which the threel ow premolars (P2,P3,P4) and the first molar were extracted. Three months after dental extraction, dental implants sites were created and lately two bilater albuccal bone dehiscence, in which four titanium dental implants were inserted. Dehiscences werer and omly assignedfor the following treatment: 1) contrai; 2) GBR;3) PRP; 4) PRP+ GBR. After 3 months, animais were sacrificed; dental implants and adjacent hard tissues were pracessed for undecalcified sections. At histometrical analysis,the parameter se valuated were bone-implant contact, bone filling area into threads, bone tissue area and bone density formed out the threads. Variance Analysis was utilized for statistical analysis of the data (p<O,O5). There sults demonstrated statically significant differences for ali parameters toward membrane treated graups (p<O,O5), although, differences were not observed when PRP was utilized( p>O,O5). Within the limits of the present study, it was concluded that PRP do not exert additional effects on bone healing and that guided bone regeneration provides increased bone formation araund dental implants / Doutorado / Periodontia / Doutor em Clínica Odontológica
79

Influência do formato do rebordo alveolar na distribuição interna das tensões em prótese parcial removível dento-implantossuportada

Martin Júnior, Manoel [UNESP] 06 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-06Bitstream added on 2014-06-13T18:07:43Z : No. of bitstreams: 1 martinjunior_m_me_araca.pdf: 1987212 bytes, checksum: 7b293d4845e041e9d49b2c3d5d18fcce (MD5) / Universidade Estadual Paulista (UNESP) / Os dados sobre a influência da forma do rebordo alveolar na distribuição interna das tensões na associação da prótese parcial removível de extremidade livre (PPREL) com os implantes osseointegrados são inconclusivos. Assim, o objetivo deste estudo foi avaliar através do método dos elementos finitos (MEF) bi-dimensional, a influência do formato do rebordo alveolar na distribuição interna das tensões. Para isso, foram confeccionados 12 (doze) modelos no programa AutoCAD 2005 (Autodesk Inc, USA), sendo: Modelo A (MA) - hemiarcada com a representação do dente natural 33 e o rebordo edentado para distal; Modelo B (MB) - semelhante ao MA com uma PPREL convencional substituindo os dentes ausentes 34, 35, 36 e 37; Modelo C (MC) - semelhante ao MB, porém com um implante do Sistema Bränemark (3,75 x 10,0 mm) posicionado na região retromolar, sob a base da prótese, conferindo apenas suporte; Modelos A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 e C4 foram baseados nos respectivos modelos: A, B e C, com a identificação numérica seguindo a forma do rebordo alveolar no plano sagital, como descrito: descendente distal (1), côncavo (2), plano (3) e ascendente distal (4). Os modelos foram exportados para o programa de elementos finitos ANSYS 8.0 (Swanson Analysis Systems, Houston, Pa) para a análise numérica. O carregamento foi realizado com forças verticais de 50 N. Os resultados mostraram que máxima tendência ao deslocamento para os rebordos analisados ocorreu de forma semelhante entre os modelos B e C, sendo: descendente distal (B1 - 0,2484 mm e C1- 0,2513 mm), plano (B3 - 0,2415 mm e C3 0,2452 mm), côncavo (B2 - 0,2377 mm e C2 0,2392 mm) e ascendente distal (B4 - 0,2255 mm e C4 - 0,2293 mm); a máxima concentração de tensão nos modelos B apresentou a seguinte ordem: descendente distal (288,77 MPa), côncavo (199,99 Mpa), plano (197,11 MPa) e ascendente distal (185,22 MPa)... . / The data about the influence of the alveolar ridge shape in the stress distribution during the association of a free-end saddle removable partial denture (FERPD) with an osseointegrated implant are inconclusive. Thus, the objective of this study was to evaluate, by bidimensional the finite element analysis (FEA), the influence of the alveolar ridge shape in the stress distribution. For this, 12 (twelve) models were created in the program AutoCAD 2005 (Autodesk Inc, USA), representing: model A (MA) - hemiarch containg only the natural tooth 33 and edentulous space for distal; model B (MB) - similar to MA with a conventional FERPD replaying the absent teeth 34, 35, 36 and 37; model C (MC) - similar to MB, however with an implant of the Sistema Bränemark (3,75 x 10,0 mm) positioned in posterior area, in order to support FERPD base; Models A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 and C4 were based on the respective models: A, B and C, with the numeric identification following the shape in the sagital plane, as described: distal descending (1), concave (2), plan (3) and distal ascendancy (4). The models were exported for the FEA hardware (ANSYS 8.0 Swanson Analysis Systems, Houston, PA) for numeric analysis. The loading were performance with vertical forces of 50 N. The results showed maximum displacement tendency (mm) were between models B and C: distal descending (B1 - 0.2484 mm and C1 - 0.2513 mm), plan (B3 - 0.2415 mm and C3 0.2452 mm), concave (B2 - 0.2377 mm and C2 0.2392 mm) and distal ascendancy (B4 - 0.2255 mm and C4 - 0.2293 mm); the maximum stress concentration for models B were distal descending (288,77 MPa), concave (199,99 MPa), plan (197,11 MPa) and distal ascendancy (185,22 MPa); the model C present an inversion between plan and distal ascending shape: C1 with 395,93 MPa, C2 with 341,49 MPa, C4 with 266,02 MPa and C3 with 219,58 MP... (Complete abstract, click electronic address below).

Page generated in 0.1273 seconds