• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 78
  • 62
  • 17
  • 8
  • 6
  • 4
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 246
  • 64
  • 35
  • 28
  • 27
  • 26
  • 23
  • 20
  • 20
  • 18
  • 18
  • 17
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Determinação multielementar de elementos traços em radiofármacos produzidos na Diretoria de Radiofarmácia por espectrometria de emissão por plasma / Multielemental determination of trace elements in radiopharmaceuticals produced at the radiopharmacy center using icp-oes technique

Angélica Tamião Tavares 29 November 2013 (has links)
Os radiofármacos são preparações farmacêuticas, que contém radionuclídeo, utilizados em medicina nuclear. O objetivo desse trabalho foi estudar as concentrações de elementos químicos, principalmente metais, em amostras de radiofármacos ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDATEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-Flúor-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. As análises foram realizadas em equipamento Vista MPX simultâneo ICP-OES (Agilent, Australia). A validação do método foi realizado segundo os critérios descritos na RDC n° 899: Guia para validação de métodos analíticos e bioanalíticos de 29 de maio de 2003. De acordo com a Farmacopeia Americana (USP), as impurezas elementares com potencial toxicidade devem ser quantificados. Uma proposta de revisão USP 35 introduz a técnica de espectrometria de emissão atômica para a análise de elementos. Os resultados de validação das análises no ICP-OES indicam a necesidade de controle da limpeza e manutenção do equipamento, alterações do sample uptake delay e avaliação da robustez com as linhas do Mg. As curvas analíticas e faixas de concentracões analisadas foram lineares com r > 0,99. Os resultados de DPR foram abaixo de 5%. Todos os resultados dos parâmetros avaliados estão de acordo com os estabelecidos pela ANVISA. / Radiopharmaceuticals are pharmaceutical preparations containing radionuclide used in nuclear medicine. The aim of this work was to study the concentrations of chemical elements, especially metals, in samples of radiopharmaceuticals ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDA-TEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-FLÚOR-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. The analyses were carried out simultaneously in an ICP-OES Vista MPX (Agilent). The method validation was performed according to the criteria defined in RDC No. 899 : Guide for validation of analytical and bioanalytical methods for May 29, 2003 of the ANVISA. According to the U.S. Pharmacopeia (USP), the elemental impurities with potential toxicity must be quantified. A proposed revision to USP 35 introduces the technique of atomic emission spectrometry for the analysis of elements. The validation results of the ICP- OES analyzes indicated the necessary to control the cleaning and maintenance of equipment, changes in sample uptake delay and robustness evaluation with the lines of Mg. The analytical curves and concentration ranges analyzed were linear with r > 0.99. The results of DPR were below 5%. All the parameters were below the established by ANVISA .
82

Analise multielementar e isotopica em compostos de uranio por espectrometria de massa com fonte de plasma induzido ( ICPMS )

OLIVEIRA JUNIOR, OLIVIO P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:23Z (GMT). No. of bitstreams: 1 06890.pdf: 3271433 bytes, checksum: 57399ce5f630231a9b2741455ed096f0 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
83

Estudo da ativacao de alvos de Mo para a producao de sup99Mo pela reacao nuclear sup98Mo(n,y) sup99Mo e comportamento das impurezas radionuclidicas do processo

NIETO, RENATA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:18Z (GMT). No. of bitstreams: 1 06443.pdf: 4052789 bytes, checksum: ad0a002c9a73bb765e639e0bde37d570 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
84

Desenvolvimento de metodologia analítica para avaliação de apixabana e suas impurezas

Ellwanger, Jéssica Bauer January 2018 (has links)
Apixabana é um novo fármaco da classe dos anticoagulantes orais utilizado na prevenção e no tratamento de eventos de tromboembolismo venoso em pacientes submetidos à cirurgia de quadril e joelho, além de reduzir os riscos de acidente vascular cerebral e fibrilação arterial. Uma vez que impurezas e contaminantes podem estar presentes no produto farmacêutico final, as agências regulatórias preveem leis para monitorar essas substâncias. O conceito de Quality by Design (QbD), uma abordagem sistemática que inicia com objetivos pré-definidos e análise de risco, está sendo amplamente utilizado no âmbito farmacêutico para desenvolver formulações e metodologias analíticas. Sendo assim, este trabalho almejou desenvolver e validar um método indicativo de estabilidade simples, rápido e sensível utilizando cromatografia líquida de alta eficiência (CLAE) para determinação simultânea da apixabana e três impurezas sintéticas aplicando a abordagem QbD. O desenho experimental foi feito através do software MODDE® 11 (Umetrics, Suíça) e executado utilizando um cromatógrafo Shimadzu® LC-20A Prominence CLAE-DAD com detecção a 220 nm. O método cromatográfico foi estabelecido utilizando uma coluna Inertsil® CN-3 (150 × 4,6 mm, 5,0 μm) com temperatura do forno de 30°C e volume de injeção de 10 μL. A constituição da fase móvel foi metanol e água (50,2:49,8) com fluxo de 1,015 mL/min sem ajuste de pH. O método foi validado seguindo as guias do ICH e da ANVISA, sendo considerado específico, sensível, linear (r > 0,999), preciso (DPRs < 10% para as impurezas) e exato. Para especificidade, foi realizada busca de produtos de degradação submetendo os comprimidos de apixabana a condições de estresse (radiação UVC, temperatura, oxidação e hidrólise). As substâncias envolvidas no presente trabalho também foram caracterizadas quimicamente e avaliadas quanto ao seu perfil toxicológico in vitro através dos ensaios de MTT e vermelho neutro. A mistura da APX e suas impurezas demonstrou toxicidade aguda, porém este resultado não se manteve durante a exposição prolongada, sugerindo um mecanismo de compensação mitocondrial. Já a impureza 3 apresentou danos significativos em 96 horas de exposição, de modo que mais estudos devem efetuados para avaliar sua toxicidade. / Apixaban is a novel anticoagulant agent used to prevent and treat venous thromboembolic events in adults who have undergone total hip or knee replacement surgery and to lower the risk of stroke in patients with atrial fibrillation. As impurities and contaminants may be present in the pharmaceutical product, current regulatory guidelines recommend monitoring such substances. The concept of Quality by Design (QbD), a systematic approach that begins with predefined objectives and risk management, is being widely used in the pharmaceutical field to develop new formulations and analytical methods. Thus, the aim of this work was to develop and validate a simple, fast and sensitive stability indicating method by high-performance liquid chromatography (HPLC) for the simultaneous determination of apixaban and three synthesis impurities using QbD approach. Experiments were designed and assessed on MODDE® 11 (Umetrics, Sweden) software and carried out in a Shimadzu® LC-20A Prominence HPLC-DAD at 220 nm. The HPLC method was established using an Inertsil® CN-3column (150 × 4.6 mm, 5.0 μm) at the temperature of 30°C and injection volume of 10 μL. The mobile phase consisted of methanol and water (50.2:49.8) at a flow rate of 1.015 mL/min with no pH adjustment. Validation of the method was conducted according to ICH and ANVISA Guidelines, which was considered specific, sensitive, linear (r > 0,999), precise (RSD < 10% for impurities) and accurate. For specificity, a degradation study was performed by exposing apixaban tablets to stress conditions (UVC radiation, temperature, oxidation and hydrolysis). The related substances in the present study were also chemically characterized and toxicological profile was evaluated by in vitro tests MTT and neutral red. The mixture of APX and its impurities showed acute toxicity, but this result did not persist during prolonged exposure, suggesting a mitochondrial compensation mechanism. Yet, impurity 3 presented significant damages in 96 hours of exposure and further studies should be considered to evaluate its toxicity.
85

Piégeage des impuretés métalliques présentes dans le silicium destiné au photovoltaïque par plasma immersion ion implantation (PIII) / Extraction of silicon metal impurities to be used for photovoltaic by plasma immersion ion implantation (PII)

Kouadri Boudjelthia, El Amin 18 December 2012 (has links)
Malgré son grand potentiel, l’énergie photovoltaïque n’arrive pas encore à trouver une grande place dans le paysage énergétique mondial. Elle se heurte à deux problèmes de taille : le coût et le rendement. Les cellules solaires à base du silicium multicristallin (mc-Si) perdent beaucoup de leur rendement à cause de la présence des impuretés métalliques. Plusieurs recherches ont montré que les cavités induites par implantation ionique sont efficaces dans le piégeage des impuretés. Mais les techniques utilisées dans l’implantation n’ont pas permis à ce procédé de se développer dans l’industrie à cause de leur coût élevé. Le plasma immersion ion implantation (PIII) est une technique bas coût qui permet d’implanter de grandes surfaces. Elle est utilisée dans le traitement de surface à l’échelle industrielle, mais à ce jour aucune étude n’a montré son utilisation dans le piégeage des impuretés dans le silicium. Dans cette thèse nous avons créé des cavités dans le mc-Si par implantation d’hydrogène par PIII. Plusieurs techniques de caractérisation ont été utilisées afin d’étudier le mécanisme de formation de ces cavités. La MET, la photoluminescence et les positons ont été utilisées pour avoir un maximum d’informations sur la nature et l’évolution des défauts créés par implantation d’hydrogène. Nous avons également étudié la différence entre les cavités formées par PIII et celles formées par implantation classique. Les cavités formées ont été utilisées, par la suite, pour le piégeage des impuretés métalliques présentes dans le mc-Si (Cu, Fe, Cr et Ni). Les résultats obtenus par SIMS ont monté l’efficacité de notre procédé dans le piégeage des impuretés métalliques. / Extraction of silicon metal impurities to be used for photovoltaic by plasma immersion ion implantation (PII)
86

Extending Spectrophotometric pHT Measurements in Coastal and Estuarine Environments

Douglas, Nora Katherine 06 April 2018 (has links)
Nearshore and estuarine environments play a vital role in the cycling of carbon, but the effects of ocean acidification in estuarine waters have not been studied as extensively as in the open ocean. One reason for this is the limitation of pH measurement capabilities in low-salinity waters. Typically, pH in these environments has been measured using potentiometric methods that are subject to uncertainties on the order of 0.01. Spectrophotometric methods for measuring pHT offer precision and accuracy superior to those of potentiometric methods. However, previous characterizations for purified sulfonephthalein indicators, used for marine spectrophotometric measurements, are not applicable to estuarine salinities. Some estuarine datasets using unpurified indicators exist, but the presence of dye impurities affects the accuracy of these characterizations. Colorimetric impurities are known to interfere with absorbance measurements and can cause errors in pH on the order of 0.02. In this work, a mathematical model has been developed to correct spectrophotometric pHT determined with unpurified m-Cresol Purple (mCP), the indicator used most widely for these measurements. The model accounts for absorbances of colorimetric impurities that interfere with absorbance by mCP. This corrective approach brings measurements made using unpurified mCP in synthetic solutions of 0.7 M NaCl into better agreement with those made using purified mCP: within ±0.004 pH units for all six indicators tested at pHT ≤ 8.0. The model is useful for both (a) research groups currently using unpurified mCP to measure pHT, and (b) retrospective correction of historic pHT datasets collected using unpurified mCP. The correction requires only that a small sample of the unpurified mCP is saved for a single-point test at high pHT (~12), and that historic absorbance measurements are archived for subsequent correction. The principles of the corrective model were applied to an historic calibration of the mCP dissociation constant (KI) at 0 ≤ S ≤ 40 and T = 298.15 K using unpurified indicator. After correction of absorbances for dye impurities, recalculation of KI was performed, and the recalculated values were combined with mCP KI data for freshwater and seawater. The combined dataset was then refitted as a function of S and T. The resulting model is representative of mCP behavior across 0 ≤ S ≤ 40 and 278.15 ≤ T ≤ 308.15 K and produces p(KIe2) values that are within ±0.004 of p(KIe2) values from previously published purified mCP calibrations. This refitting approach was also applied to pHT determinations made with Thymol Blue (TB) and Cresol Red (CR), two sulfonephthalein indicators that have been previously used in waters outside the indicating range of mCP. The models, which were of the same form as the estuarine p(KIe2) model for mCP, performed approximately as well as the mCP model: with the exception of one high-salinity, high-temperature TB datum, all residuals were within ±0.0043 of the previously published TB and CR calibrations. Finally, an internal consistency analysis was performed using carbon chemistry data collected during two recent coastal ocean acidification research cruises. For pHT measurements performed during both cruises, purified mCP was used, and corresponding measurements of total alkalinity (TA) and dissolved inorganic carbon (DIC) were conducted. Both cruises included excursions into the Columbia River, where low salinities prevent usage of the marine p(KIe2) model for purified mCP. The Columbia River samples provided the opportunity to evaluate the internal consistency of pHT measurements made in low-salinity waters using the refitted estuarine p(KIe2) model. Although internal consistency agreement in the estuarine range is poor compared to marine measurements, pHT calculated using the new estuarine model compared well with pHT calculated using the previously published estuarine mCP model. The poor internal consistency in the estuarine range, even when making state-of-the-art pH measurements, points toward the need for a more robust characterization of the carbonic acid dissociation constants in the estuarine salinity range. This characterization should take into account the contributions of organic acids to total alkalinity in nearshore waters.
87

Determinação de impurezas em cobre eletrolítico por espectrometria de massas com plasma indutivamente acoplado

Barbour, Reinaldo January 2011 (has links)
102f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-03-27T17:17:03Z No. of bitstreams: 1 Tese doutorado final Reinaldo Barbour.pdf: 1224301 bytes, checksum: b37e38d9ef21943dba24e8f3638efbcd (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-04-19T13:16:36Z (GMT) No. of bitstreams: 1 Tese doutorado final Reinaldo Barbour.pdf: 1224301 bytes, checksum: b37e38d9ef21943dba24e8f3638efbcd (MD5) / Made available in DSpace on 2013-04-19T13:16:36Z (GMT). No. of bitstreams: 1 Tese doutorado final Reinaldo Barbour.pdf: 1224301 bytes, checksum: b37e38d9ef21943dba24e8f3638efbcd (MD5) Previous issue date: 2011 / CAPES / A determinação de impurezas em cobre eletrolítico, na faixa de μg g-1 e sub μg g-1, é muito importante para caracterizar o cobre de alta pureza (99,99%). As suas propriedades físicas e químicas como maleabilidade, condutividade térmica e elétrica são fundamentais nas aplicações industriais nos setores de eletricidade e eletrônica. Metais e ametais como Ag, As, Bi, Co, Cr, Fe, Mn, Ni, Pb, Sb, Se, Sn,Te e Zn modificam estas propriedades deteriorando sua maleabilidade e condutividade. A espectrometria de massas com plasma indutivamente acoplado (ICP-MS) tem sido muito empregada para a determinação elementar, em amostras industriais, devido às suas características, principalmente as relacionadas com a capacidade multielementar, a rapidez e a alta sensibilidade. As principais desvantagens da técnica são as interferências isobáricas e poliatômicas, além daquelas relacionadas à matriz. Este trabalho teve por objetivo estabelecer um procedimento analítico validado para a determinação de elementos contaminantes por ICP-MS em amostras de cobre eletrolítico, de forma a garantir os limites de quantificação exigidos para a certificação do cobre. O equipamento empregado foi operado nos modos padrão e CCT (célula de colisão que utiliza 1,0% (v/v) NH3 em He balanço) com comutação automática. As amostras e materiais de referência certificados foram digeridos, em triplicata, empregando bloco aquecedor, seguindo o procedimento: 10  1 mg de amostra com 2 mL de HNO3 1:1 (v/v) à 70ºC. A diluição final foi de 5000x, o que contribui para minimização dos efeitos de matriz provenientes da alta concentração dos íons de cobre (~200 ug g-1). Os isótopos selecionados no modo normal de operação do equipamento foram: 55Mn, 59Co, 60Ni, 68Zn, 75As, 107Ag, 118Sn, 121Sb, 128Te, 208Pb e 209Bi. Para o modo com célula de colisão, os isótopos foram: 52Cr, 56Fe, 57Fe, 77Se e 78Se. A faixa linear estudada foi de 0,01 a 2 ng g-1. Os limites de quantificação encontrados (μg g-1 no cobre) foram: Ag (0,05), As (0,2), Bi (0,05), Co (0,1), Cr (0,2), Fe (0,5), Mn (0,2), Ni (0,2), Pb (0,1), Sb (0,2), Se (0,2), Sn (0,2),Te (0,1) e Zn (0,5). A exatidão foi avaliada pela analise dos seguintes materiais de referência certificados: BAM-M381, BAM-M382, BAM-M383, BAM-M384 (Pure Copper, BAM; Federal Institute for Materials Research and Testing) e NIST 495, NIST 496, NIST 457 (National Institute of Standards and Technology) sendo que a maioria das recuperações obtidas foram entre 80 e 120% e os %RSD menores que 10% (Se < 20%). O efeito de matriz foi avaliado através das técnicas de calibração: calibração externa com padrões internos, calibração com adição de analito e calibração com uso dos CRMs e não houve diferença significativa dos resultados. A técnica DC-ARC OES foi empregada para comparação dos resultados. A avaliação dos resultados das amostras reais de bobinas foi feita por meio de ensaios interlaboratoriais e do critério z score. Por este critério, a maioria dos resultados obtidos foram considerados excelentes. Pode-se concluir que o método proposto, empregando ICP-MS, é adequado para determinação multielementar / Salvador
88

Determinação de pureza de fármacos por meio de métodos diretos e indiretos : vantagens e desvantagens / Quantification of drugs by means of direct and indirect methods: advantages and disadvantages

Junqueira, César Alexandre January 2012 (has links)
Pureza é um dos principais atributos de qualidade de matérias-primas farmacêuticas, já que a identificação e determinação quantitativa de impurezas podem ajudar a controlar/minimizar o risco de efeitos adversos de medicamentos. O papel dos métodos de doseamento, tanto específicos como não específicos, em caracterizar a qualidade de matérias-primas farmacêuticas, tem sido questionado. Por outro lado, a abordagem do balanço de massas, que quantifica cada impureza orgânica bem como substâncias voláteis e cinzas, e então subtrai a soma destas impurezas de 100%, pode oferecer uma melhor maneira de determinar com exatidão se o fármaco atende aos critérios regulatórios de aceitação e de detectar com confiança mudanças não esperadas na qualidade do fármaco. O objetivo do estudo foi comparar métodos de doseamento compendiais com essa abordagem de balanço de massas na determinação do conteúdo de substância ativa e caracterização da qualidade de matérias-primas farmacêuticas. Os fármacos empregados neste estudo foram o nifedipino, o diazepam, a glibenclamida e a estavudina. A identificação e caracterização dos fármacos foram realizadas por meio de determinação do ponto de fusão e espectroscopia no infravermelho. Para a determinação quantitativa foram empregados os métodos presentes na Farmacopéia Brasileira, United States Pharmacopeia e British Pharmacopeia. O detector de aerossol carregado (CAD) foi acoplado ao sistema de cromatografia à líquido de alta eficiência para comparação das respostas com o detector ultravioleta. Os resultados demonstraram a viabilidade do método indireto, que oferece dados mais precisos que os do método direto, além de favorecer um controle de qualidade mais focado no perfil de impurezas. / Purity is one of the main attributes of quality of bulk drug materials, since the identification and quantitative determination of impurities can help to avoid or at least control/minimize the risk of their contribution to the side effects profile of drug materials. The role of assay methods, either specific or non-specific, in characterizing the quality of bulk drug materials, has been questioned. On the other hand, the mass balance approach, which quantifies every organic impurity as well as volatile substances and ashes, and then subtracts the sum of these impurities from 100%, can provide a better way to accurately determine if the drug substance meets the regulatory acceptance criteria and to reliably detect unexpected changes in the quality of the drug substance. The objective of this study was to compare compendial assay methods with a mass balance approach in the determination of the active ingredient content and characterization of the quality of bulk drug materials. The identification and characterization of the drugs were accomplished through determination of melting point and infrared spectroscopy. The methods from the Farmacopeia Brasileira, United States Pharmacopeia and British Pharmacopoeia were used for the quantitative determination of the drugs. The drug related impurities were determined by high performance liquid chromatography (HPLC) equipped with an ultraviolet (UV) detector and charged aerossol detector (CAD) in tandem. The results demonstrated the feasibility of the indirect method, which offers more precise data than those from the direct method, besides it enables the quality control to be focused on the impurity profile.
89

Desenvolvimento de método analítico para avaliação de impurezas orgânicas de ticagrelor

Bueno, Lívia Maronesi January 2016 (has links)
O ticagrelor é um novo fármaco destinado para a prevenção de síndromes coronarianas agudas (SCA) caracterizadas pela formação de placas ateroscleróticas que se rompem no interior das artérias. Atua de forma diferenciada na inibição da ação plaquetária, inibindo de forma reversível e não competitiva o receptor P2Y12, o qual atua diretamente na agregação das plaquetas. Este medicamento está registrado no Brasil desde 2011, sob nome comercial de Brilinta®, na forma de comprimidos revestidos de 90 mg, e, até o presente momento, são poucos os estudos publicados a respeito do controle de impurezas e produtos de degradação do fármaco. No presente trabalho foi desenvolvido um método por cromatografia líquida de alta eficiência (CLAE) adaptado para a análise de impurezas orgânicas do ticagrelor. O método por CLAE foi estabelecido utilizando equipamento Agilent 1200 Series, acoplado a detector de arranjo de diodos (DAD) em 270 nm, com coluna cromatográfica Zorbax Plus C8 (150 x 4,6 mm, 5,0 μm), fluxo de 0,7 ml/min, volume de injeção de 20 μl e temperatura constante de 25ºC. A fase móvel foi composta de acetonitrila: acetato de amônio 50 mM (57:43, v/v), pH 8,2. O método demonstrou ser específico, linear, preciso, exato e robusto, sendo adequado para a finalidade a que foi proposto. Além disso, foram elucidados os principais produtos de degradação originados quando as amostras dos comprimidos de ticagrelor em solução foram expostas à radiação UVC por duas horas, com base em um estudo preliminar de estabilidade do mesmo. Os mecanismos envolvidos na degradação fotolítica do ticagrelor também foram propostos. / Ticagrelor is a new drug intended for the prevention of acute coronary syndromes (ACS) characterized by the formation of atherosclerotic plaques that rupture inside the arteries. Ticagrelor reversibly binds to P2Y12 receptor, which acts directly on platelet aggregation. The drug was approved in Brazil in 2011, under the comercial name Brilinta® in the form of coated tablets of 90 mg, and until now has few published studies about the impurities control and degradation products. In this study, it was developed a method by high-performance liquid chromatography (HPLC) for the analysis of organic impurities of ticagrelor. The HPLC method was established using Agilent 1200 Series equipment coupled to photodiode array detector (PDA) at 270 nm with a Zorbax Plus C8 column (150 x 4.6 mm, 5.0 μm), flow rate of 0.7 ml/min, injection volume of 20 μL, and a constant temperature of 25°C. The mobile phase consisted of acetonitrile: ammonium acetate 50 mM (57:43 v/v), pH 8.2. The method demonstrated to be specific, linear, precise, accurate and robust, being suitable for the intended purpose. Besides, the mayor degradation products formed when samples of ticagrelor tablets in solution were exposed to UVC radiation for two hours were elucidated based on a preliminary stability study. The mechanisms involved in photolytic degradation of ticagrelor have also been proposed.
90

Análise de impurezas orgânicas no cloridrato de besifloxacino por cromatografia líquida de alta eficiência com eluição isocrática e gradiente

Manoel, Joanna Wittckind January 2016 (has links)
A análise de impurezas é uma etapa importante no controle de qualidade do insumo farmacêutico e do produto final. Provenientes da síntese do medicamento ou dos excipientes, mesmo em pequenas concentrações, as impurezas podem afetar a eficácia e a segurança. No presente trabalho foram desenvolvidos e validados dois métodos empregando cromatografia líquida de alta eficiência (CLAE) para a avaliação do besifloxacino e sua impureza de síntese, um com eluição isocrática e outro com eluição gradiente. As análises por CLAE com modo de eluição isocrática foram executadas utilizando coluna Ciano, mantida a 25 °C. A fase móvel foi constituída por 0,5% de trietilamina (pH 3,0) : acetonitrila (88:12 v/v), eluída na vazão de 1,0 mL/min com detecção a 330 nm. O método com eluição gradiente foi conduzido com a mesma coluna e componentes da fase móvel modificando apenas as proporções entre fase orgânica e aquosa durante as análises. Os procedimentos foram validados de acordo com guias aceitos internacionalmente, observando-se resultados dentro dos limites aceitáveis. Os métodos apresentaram-se lineares na faixa de 140 a 260 μg/mL para o besifloxacino e de 0,3 a 2,3 μg/mL para a impureza A. Com volume de injeção de 20 μL, os limites de detecção e quantificação foram, respectivamente, 0,07 e 0,3 μg/mL. A precisão foi alcançada para todas as análises realizadas, obtendo DPR inter-dia igual a 6,47 e 6,36 para a impureza A com eluição isocrática e gradiente, respectivamente. A exatidão foi superior a 99% e a robustez apresentou resultados satisfatórios. No método isocrático obteve-se tempo de análise de 25 min e no gradiente de 15 min. O número de pratos teóricos no modo isocrático foi na ordem de 5000 enquanto no modo gradiente foi na ordem de 45000, ou seja, obteve-se maior eficiência da coluna com alteração da composição da fase móvel durante a eluição. No insumo besifloxacino e no produto farmacêutico utilizados neste trabalho, impurezas relacionadas estavam presentes, mas a impureza A não foi detectada. Os métodos propostos, considerando-se o limite de quantificação, podem ser aplicados na determinação quantitativa da impureza A na análise da matéria prima do besifloxacino, assim como na suspensão oftálmica. / Analysis of impurities is an important step in quality control of pharmaceutical ingredients and final products. From drug synthesis or excipients, even in small concentrations, impurities may affect efficacy and safety. In the present study two chromatographic methods were developed and validated for high-performance liquid chromatography (HPLC) for the assessment of besifloxacin and its synthesis impurity, one with isocratic and another with gradient elution. Analyses by HPLC in isocratic elution mode were performed using Cyano column maintained at 25 °C. Mobile phase was composed of 0.5% triethylamine (pH 3.0): acetonitrile (88:12 v/v) eluted at a flow rate of 1.0 ml/min with detection at 330 nm. The method with gradient elution was carried out with the same column and mobile phase components modifying only proportion between organic and aqueous phase during analysis. The procedures have been validated according to internationally accepted guidelines, obtaining results within acceptable limits. The methods presented a linear response from 140-260 μg/mL for besifloxacin and from 0.3 to 2.3 mg/mL for impurity. With the injection volume of 20 μL, the limit od detection and limit of quantitation were, respectively, 0.07 and 0.3 μg/mL. Precision was achieved for all analyses, obtaining inter-day RSD equal to 6.47 and 6.36 for impurity A with isocratic and gradient elution, respectively. The accuracy was higher than 99% and robustness exhibited satisfactory results. In the isocratic method was obtained analysis time 25 min and 15 min gradient. The number of theoretical plates in the isocratic mode was of the order of 5000 while in the gradient mode was of the order of 45000, that is, gave greater efficiency of the column by changing the mobile phase composition during elution. In raw material of besifloxacin and pharmaceutical product used in this study, related impurities were present but the impurity A was not detected. The proposed methods, considering the limit of quantitation, can be in quantitative determination of impurity A in the analysis of besifloxacin raw material, as well as in ophthalmic suspension.

Page generated in 0.0992 seconds