• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mensuração da sensibilidade corneana e produção lacrimal em cães submetidos à facoemulsificação / Corneal sensitivity and tear production measurement in dogs submitted to phacoemulsification

Góes, Ana Carolina Almeida de 26 February 2014 (has links)
A facoemulsificação é, atualmente, considerada a técnica de eleição no tratamento da catarata, uma das principais causas de perda de visão, em cães. O procedimento demanda a realização de incisões na córnea para acesso à câmara anterior. Tais incisões, a despeito da extensão reduzida, podem lesar a inervação da córnea, comprometendo sua sensibilidade e, consequentemente, influenciar a produção lacrimal. Objetivando-se avaliar tais intercorrências, concebeu-se aferir a sensibilidade corneana e a produção lacrimal aquosa em cães submetidos à facoemulsificação. Para tanto, tais parâmetros foram investigados em 20 cães com idade, sexo, raça e peso variáveis. Os procedimentos cirúrgicos foram realizados em um único olho (OT), sendo o olho não operado utilizado como controle (OC). A sensibilidade da córnea foi mensurada com o estesiômetro de Cochet-Bonnet® e a produção lacrimal pelos testes do fenol vermelho e de Schirmer, em ambos os olhos. Os parâmetros foram aferidos previamente ao procedimento cirúrgico (M0 - valores basais) e, posteriormente, após sete dias (M1), 15 dias (M2), 30 dias (M3), 90 dias (M4) e 180 dias (M5). Os valores da produção lacrimal aferida com o teste do fenol vermelho, em M1, não diferiram dos obtidos previamente à cirurgia (M0), nos OT e OC; diferenças significativas foram observadas de M2 a M5, com valores superiores aos basais (M0), em ambos os olhos. Os resultados da mensuração lacrimal com o teste de Schirmer e da sensibilidade corneana à estesiometria (em cm e mm/g2) não diferiram dos basais (M0) em quaisquer dos períodos de avaliação (M1 a M5), em ambos os olhos. Os resultados obtidos ao estudo permitiram verificar que a realização da cirurgia de catarata por facoemulsificação, como fora proposto, não resulta em diminuição da sensibilidade corneana e produção lacrimal aquosa. / Phacoemulsification is considered the technique of choice for surgical extraction of cataracts, which is a leading cause of blindness in dogs. The procedure requires corneal incisions to enter the anterior chamber. These incisions, despite their reduced extensions, may damage the corneal innervation, compromising its sensitivity and, also, the tear production. Aiming to evaluate these consequences, this study intended to measure the corneal sensitivity and aqueous tear production in dogs undergoing phacoemulsification. These parameters were evaluated in 20 dogs, with different ages, genders, breeds and weights. Surgical procedures were performed in one eye (OT), and the fellow eye was used as a control (OC). Corneal sensitivity was measured with the Cochet-Bonnet® aesthesiometer and tear production by the phenol thread red test and Schirmer tear test, in both eyes. The parameters were measured prior to the surgery (M0 - baseline values) and after seven days (M1), 15 days (M2), 30 days (M3), 90 days (M4) and 180 days (M5). Tear production values measured with the phenol red test, in M1, were not different from the values measured prior to the surgery (M0), in OT and OC; significant differences were noticed from M2 to M5, with higher values when compared to baseline values (M0), in both eyes. Schirmer tear test and corneal sensitivity (in cm and mm/g2) values were not different from basal values (M0) in any of the evaluation times (M1 to M5), in both eyes. Our study outcomes suggest that phacoemulsification, as proposed previously, does not decrease the corneal sensitivity and aqueous tear production.
2

Matéria gráfica: idéia e imagem. / Graphic matter: idea and image

Jacqueline Aronis 30 April 2009 (has links)
Gravura e desenho como matéria gráfica; como registros de ideias e anotações decorrentes de uma memória constitutiva.Sonhos e projetos como proposição e realização de um trabalho. / Printmaking and drawing as graphic matter.Ideas and notes arising from a constitutive memory.Dreams and projects as proposal and materialization of a work of art.
3

Matéria gráfica: idéia e imagem. / Graphic matter: idea and image

Aronis, Jacqueline 30 April 2009 (has links)
Gravura e desenho como matéria gráfica; como registros de ideias e anotações decorrentes de uma memória constitutiva.Sonhos e projetos como proposição e realização de um trabalho. / Printmaking and drawing as graphic matter.Ideas and notes arising from a constitutive memory.Dreams and projects as proposal and materialization of a work of art.
4

Identificação das variáveis que ocasionam a variação de tonalidade utilizando a técnica de decoração por cilindros de silicone gravados a laser

Ferraço, Fabio 30 November 2015 (has links)
Submitted by Alison Vanceto (alison-vanceto@hotmail.com) on 2016-10-20T11:09:05Z No. of bitstreams: 1 TeseFF.pdf: 27812047 bytes, checksum: d614c00f45e5022ae17e6304ed5531be (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-11-08T18:34:50Z (GMT) No. of bitstreams: 1 TeseFF.pdf: 27812047 bytes, checksum: d614c00f45e5022ae17e6304ed5531be (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-11-08T18:34:57Z (GMT) No. of bitstreams: 1 TeseFF.pdf: 27812047 bytes, checksum: d614c00f45e5022ae17e6304ed5531be (MD5) / Made available in DSpace on 2016-11-08T18:35:04Z (GMT). No. of bitstreams: 1 TeseFF.pdf: 27812047 bytes, checksum: d614c00f45e5022ae17e6304ed5531be (MD5) Previous issue date: 2015-11-30 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A major problem in the production of ceramic tiles for coating is the variation of tonality. The determination of their origin within the entire production process and to minimize its occurrence by the manufacturer is essential. In 2014 the production was 903.3 million square meters, with an estimate production for 2015 of 969.3 million square meters, which justifies studies of varying shades in production lines ceramic tiles. For the execution of this work, some variables will be fixed without any loss in accuracy of the results to be obtained, if only because some of them are already inherent in the product development flow: ink (formulation); type of glaze and engobe, decorating cylinder characteristics (type of silicone, incisions, cylinder size), basic design, set-up decoration equipment and operating condition. The variables studied were: Density and viscosity of silkscreen ink; Temperature of the ceramic carrier; Production speed; Cylinder pressure on the tile; Blade Pressure on the cylinder; Blade angle of attack and support surface humidity. It was observed that the variables density and viscosity; Decorating speed and variation of blade height on the cylinder are the variables that most affect the tone variation factor within a production. For the three cases studied, none of the incisions resulted in filling and form an ideal decorated dot regarding to the expected geometry and desired for an ideal decoration (spherical points or ellipse) in any of the tested variables. In all cases there is a maximum point reached by the variables studied, which gave a better discharge and consequently a better decoration. In each tone range studied there is a combination of variables which best accomplishes the deposition points on the enamel. / Um dos principais problemas na produção de placas cerâmicas para revestimento é a variação de tonalidade. A determinação de sua origem dentro de todo o processo de produção e a minimização de sua ocorrência pelo fabricante é fundamental. Em 2014 a produção foi de 903,3 milhões de metros quadrados, com estimativa para 2015 de 969,3 milhões de metros quadrados, o que justifica a realização de estudos sobre variação de tonalidades em linhas de produção de revestimentos cerâmicos. Para a execução deste trabalho, algumas variáveis serão fixadas sem qualquer prejuízo na veracidade dos resultados que se pretende obter, mesmo porque algumas delas já são inerentes ao fluxo de desenvolvimento de produtos: tinta (formulação); tipo de esmalte e engobe, características do cilindro de decoração (tipo de silicone, incisões, dimensão do cilindro), desenho base, ajustes (set up) do equipamento de decoração e condição de operação. As variáveis testadas foram: densidade e viscosidade da tinta serigráfica; temperatura do suporte cerâmico; velocidade de produção; pressão do cilindro sobre a peça; pressão da lâmina sobre o cilindro; ângulo de ataque da lâmina e umidade superficial do suporte. Foi observado que as variáveis densidade e viscosidade; velocidade de decoração e variação da altura da lâmina sobre o cilindro são as que mais afetam o fator de variação de tonalidade dentro de uma produção. Para os três casos estudados, nenhuma das incisões apresentou o preenchimento e a formação de pontos com a geometria esperada e desejada para uma decoração ideal (pontos esféricos ou em elipse) em nenhuma das variáveis testadas. Em todos os casos existe um ponto máximo atingido pela variável estudada, o qual proporcionou uma melhor descarga e consequentemente uma melhor decoração. Em cada faixa de tons estudado existe uma combinação de variáveis que melhor realiza a deposição de pontos sobre o esmalte.
5

Mensuração da sensibilidade corneana e produção lacrimal em cães submetidos à facoemulsificação / Corneal sensitivity and tear production measurement in dogs submitted to phacoemulsification

Ana Carolina Almeida de Góes 26 February 2014 (has links)
A facoemulsificação é, atualmente, considerada a técnica de eleição no tratamento da catarata, uma das principais causas de perda de visão, em cães. O procedimento demanda a realização de incisões na córnea para acesso à câmara anterior. Tais incisões, a despeito da extensão reduzida, podem lesar a inervação da córnea, comprometendo sua sensibilidade e, consequentemente, influenciar a produção lacrimal. Objetivando-se avaliar tais intercorrências, concebeu-se aferir a sensibilidade corneana e a produção lacrimal aquosa em cães submetidos à facoemulsificação. Para tanto, tais parâmetros foram investigados em 20 cães com idade, sexo, raça e peso variáveis. Os procedimentos cirúrgicos foram realizados em um único olho (OT), sendo o olho não operado utilizado como controle (OC). A sensibilidade da córnea foi mensurada com o estesiômetro de Cochet-Bonnet® e a produção lacrimal pelos testes do fenol vermelho e de Schirmer, em ambos os olhos. Os parâmetros foram aferidos previamente ao procedimento cirúrgico (M0 - valores basais) e, posteriormente, após sete dias (M1), 15 dias (M2), 30 dias (M3), 90 dias (M4) e 180 dias (M5). Os valores da produção lacrimal aferida com o teste do fenol vermelho, em M1, não diferiram dos obtidos previamente à cirurgia (M0), nos OT e OC; diferenças significativas foram observadas de M2 a M5, com valores superiores aos basais (M0), em ambos os olhos. Os resultados da mensuração lacrimal com o teste de Schirmer e da sensibilidade corneana à estesiometria (em cm e mm/g2) não diferiram dos basais (M0) em quaisquer dos períodos de avaliação (M1 a M5), em ambos os olhos. Os resultados obtidos ao estudo permitiram verificar que a realização da cirurgia de catarata por facoemulsificação, como fora proposto, não resulta em diminuição da sensibilidade corneana e produção lacrimal aquosa. / Phacoemulsification is considered the technique of choice for surgical extraction of cataracts, which is a leading cause of blindness in dogs. The procedure requires corneal incisions to enter the anterior chamber. These incisions, despite their reduced extensions, may damage the corneal innervation, compromising its sensitivity and, also, the tear production. Aiming to evaluate these consequences, this study intended to measure the corneal sensitivity and aqueous tear production in dogs undergoing phacoemulsification. These parameters were evaluated in 20 dogs, with different ages, genders, breeds and weights. Surgical procedures were performed in one eye (OT), and the fellow eye was used as a control (OC). Corneal sensitivity was measured with the Cochet-Bonnet® aesthesiometer and tear production by the phenol thread red test and Schirmer tear test, in both eyes. The parameters were measured prior to the surgery (M0 - baseline values) and after seven days (M1), 15 days (M2), 30 days (M3), 90 days (M4) and 180 days (M5). Tear production values measured with the phenol red test, in M1, were not different from the values measured prior to the surgery (M0), in OT and OC; significant differences were noticed from M2 to M5, with higher values when compared to baseline values (M0), in both eyes. Schirmer tear test and corneal sensitivity (in cm and mm/g2) values were not different from basal values (M0) in any of the evaluation times (M1 to M5), in both eyes. Our study outcomes suggest that phacoemulsification, as proposed previously, does not decrease the corneal sensitivity and aqueous tear production.
6

Simulação e avaliação de incisões cirúrgicas com realidade virtual

Moura, Ives Fernando Martins Santos de 29 July 2017 (has links)
Submitted by Fernando Souza (fernando@biblioteca.ufpb.br) on 2017-10-02T13:42:54Z No. of bitstreams: 1 arquivototal.pdf: 2999468 bytes, checksum: 956cae684176d28e417f331d31b46a00 (MD5) / Made available in DSpace on 2017-10-02T13:42:54Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2999468 bytes, checksum: 956cae684176d28e417f331d31b46a00 (MD5) Previous issue date: 2017-07-29 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Incisions are a common task in most surgical procedures. Their learning is traditionally done in universities or teaching centers with the use of synthetic materials, animal parts, or, in more advanced stages, in real patients under the supervision of professionals. The use of simulators can contribute in this context of training, since with them it is possible to realistically simulate the materials used, carry out the practice repeatedly and immediately and automatically assess students' performance. Simulators capable of providing evaluation for the incision made in a given procedure are not common, and even those that exist do not have a specific assessment system for this task. The present study aimed to propose and develop an assessment system for surgical incisions simulated with computational methods, identifying the basic components of this process and using appropriate decision models for each of them. For this, the concepts and variables related to this procedure were studied, highlighting their most relevant characteristics and looking for ways to better provide assessment for them. The developed system considers two steps for the assessment of the incision, pre-surgical and surgical. The classical logic was the decision model used for most of the variables, with specific rules to deal with the particularities of each one. In order to evaluate the incision trajectory, the Support Vector Machine model was selected after experiments that compared the accuracy of the assessment of different decision models applied to databases containing rectilinear incision paths. For the validation of the system, metrics for the submental incision, component of the mandibular reconstruction procedure, used in the treatment of mandibular symphysis fractures, which has high prevalence in Brazil and in the world, were obtained and applied in an incision simulation in this region of the body. A computational incision simulation, the conceptualization of the evaluation system, a concrete implementation applied to the problem of the submental incision and conceptual maps, which systematize the knowledge used from different points of view, were produced in this work. It was verified that the assessment system responded adequately, with the classical logic rules and the Support Vector Machine providing results in accordance with the metrics used. Thus, it is observed that the assessment system proposed in this work represents an adequate tool for the use in the training of incision techniques. / As incisões são uma tarefa comum na maioria dos procedimentos cirúrgicos. O aprendizado delas é tradicionalmente feito nas universidades ou centros de ensino com o uso de materiais sintéticos, peças de animais, ou, em estágios mais avançados, em pacientes reais com a supervisão de profissionais. O uso de simuladores pode contribuir neste contexto de treinamento, uma vez que com eles é possível simular de forma realista os materiais utilizados, realizar a prática repetidas vezes e avaliar de forma imediata e automática o desempenho dos estudantes. Simuladores capazes de fornecer avaliação para a incisão feita em determinado procedimento não são comuns, e mesmo os existentes não possuem um método de avaliação específico para esta tarefa. O presente trabalho teve por objetivo propor e desenvolver um sistema de avaliação para incisões cirúrgicas simuladas com métodos computacionais, identificando os componentes básicos deste processo e empregando modelos de decisão adequados para cada um deles. Para isso, foram levantados os conceitos e as variáveis relacionadas a este procedimento, destacando suas características mais relevantes e buscando formas de melhor fornecer avaliação para eles. O sistema desenvolvido considera duas etapas para a avaliação da incisão, pré-cirúrgica e cirúrgica. A lógica clássica foi o modelo de decisão utilizado para a maior parte das variáveis, havendo regras específicas para lidar com as particularidades de cada uma. Para a avaliação da trajetória da incisão foi utilizado o modelo Support Vector Machine, selecionado após a realização de experimentos que compararam a precisão da avaliação de diferentes modelos de decisão aplicados a bancos de dados contendo caminhos de incisões retilíneas. Para a validação do sistema, métricas para a incisão submentoniana, componente do procedimento de reconstrução mandibular, utilizada no tratamento de fraturas na sínfise mandibular, o qual tem alta prevalência no Brasil e no mundo, foram obtidas e aplicadas em uma simulação de incisão nesta região do corpo. Foram produzidos então uma simulação de incisão computacional, a conceitualização do sistema de avaliação, uma implementação concreta aplicada ao problema da incisão submentoniana e mapas conceituais, que sistematizam os conhecimentos utilizados a partir de diferentes pontos de vista. Verificou-se que o sistema de avaliação respondeu adequadamente, com as regras da lógica clássica e a Support Vector Machine provendo resultados em conformidade com as métricas utilizadas. Desta forma, observa-se que o sistema de avaliação proposto neste trabalho representa uma ferramenta adequada para o uso no treinamento de técnicas de incisão.
7

Técnica simplificada de colecistectomia laparoscópica com duas incisões / Simplified laparoscopic cholecystectomy with two incisions

Abaid, Rafael Antoniazzi 11 January 2018 (has links)
INTRODUÇÃO: Cerca de 20% da população é portadora de colelitíase, sendo esta afecção a principal causa abdominal de internação hospitalar em países desenvolvidos. Considerando-se que somente nos Estados Unidos são realizadas cerca 700.000 colecistectomias a cada ano, pode-se estimar a importância do problema para a saúde pública. A diminuição do número de incisões tem o potencial de reduzir o trauma cirúrgico e oferecer melhor resultado estético. OBJETIVOS: Descrever técnica de colecistectomia laparoscópica com duas incisões (CL2i) utilizando apenas material convencional, sem aumentar complicações, nem tempo operatório, oferecendo a mesma segurança da colecistectomia videolaparoscópica convencional. MÉTODO: Série prospectiva de casos consecutivos, comparada a outra série histórica de casos operados pela técnica laparoscópica convencional (CLC). A CL2i foi realizada com 3 portais em 2 incisões, sendo dois na incisão umbilical e outro no epigástrio. Foram operados 72 pacientes (36 em cada grupo) pelo mesmo cirurgião. RESULTADOS: Não houve diferença estatística entre os grupos quanto sexo, média de idade, índice de massa corpórea (IMC) e tempo de internação. Os procedimentos foram classificados pelo cirurgião de acordo com o grau de dificuldade e não houve diferença entre as séries (p < 0,05). Ocorreram complicações menores em 5,6% (n = 2) procedimentos em cada grupo. Não houve diferença entre as médias de tempo operatório (p= 0,989), que foram de 49 (IC95% 42 a 56) min na CLC e 40 (IC95% 35 a 44) min na CL2i. Não houve necessidade de portais adicionais em nenhum caso, nem de conversão para cirurgia aberta. CONCLUSÕES: A técnica de colecistectomia laparoscópica com duas incisões (CL2i) é factível, segura e com bom resultado estético, permitindo operar utilizando apenas instrumental laparoscópico convencional, sem aumentar tempo operatório ou risco de complicações / INTRODUCTION: About 20% of the population has cholelithiasis and this is the main abdominal cause of hospitalization in developed countries. Considering that only in the United States about 700,000 cholecystectomies are done each year, it is possible to estimate the importance of the problem for public health. Decreasing the number of incisions can reduce surgical trauma and offer better aesthetic results. OBJECTIVE: To describe a two-incision laparoscopic cholecystectomy technique (TILC) using only conventional material, without increasing complications, nor operative time, offering the same safety as conventional laparoscopic cholecystectomy. METHOD: A consecutive and prospective case series, compared to another historical series operated by conventional laparoscopy cholecystectomy (LC). The TILC was performed with 3 trocars in 2 incisions, two trocars in umbilical incision and one in epigastrium. A total of 72 patients were operated on by the same surgeon (36 in each group). RESULTS: There were no significant differences between groups for gender, mean age, body mass index (BMI) or length of hospital stay. The procedures were classified by the surgeon according to surgical difficulty and there was no difference between the series (p < 0.05). There were minor complications in 5.6% (n = 2) procedures in each group. There were no differences between means of operative time (p = 0.989), which were 49 (95% CI 42 to 56) min in LC and 40 (CI 95% 35 to 44) min in TILC. There was no need for additional portals in any case, nor for conversion to open surgery. CONCLUSIONS: Two-incision laparoscopic cholecystectomy (TILC) is feasible, safe and with good aesthetic result, using the same instruments of LC, without increasing operative time or complications
8

Técnica simplificada de colecistectomia laparoscópica com duas incisões / Simplified laparoscopic cholecystectomy with two incisions

Rafael Antoniazzi Abaid 11 January 2018 (has links)
INTRODUÇÃO: Cerca de 20% da população é portadora de colelitíase, sendo esta afecção a principal causa abdominal de internação hospitalar em países desenvolvidos. Considerando-se que somente nos Estados Unidos são realizadas cerca 700.000 colecistectomias a cada ano, pode-se estimar a importância do problema para a saúde pública. A diminuição do número de incisões tem o potencial de reduzir o trauma cirúrgico e oferecer melhor resultado estético. OBJETIVOS: Descrever técnica de colecistectomia laparoscópica com duas incisões (CL2i) utilizando apenas material convencional, sem aumentar complicações, nem tempo operatório, oferecendo a mesma segurança da colecistectomia videolaparoscópica convencional. MÉTODO: Série prospectiva de casos consecutivos, comparada a outra série histórica de casos operados pela técnica laparoscópica convencional (CLC). A CL2i foi realizada com 3 portais em 2 incisões, sendo dois na incisão umbilical e outro no epigástrio. Foram operados 72 pacientes (36 em cada grupo) pelo mesmo cirurgião. RESULTADOS: Não houve diferença estatística entre os grupos quanto sexo, média de idade, índice de massa corpórea (IMC) e tempo de internação. Os procedimentos foram classificados pelo cirurgião de acordo com o grau de dificuldade e não houve diferença entre as séries (p < 0,05). Ocorreram complicações menores em 5,6% (n = 2) procedimentos em cada grupo. Não houve diferença entre as médias de tempo operatório (p= 0,989), que foram de 49 (IC95% 42 a 56) min na CLC e 40 (IC95% 35 a 44) min na CL2i. Não houve necessidade de portais adicionais em nenhum caso, nem de conversão para cirurgia aberta. CONCLUSÕES: A técnica de colecistectomia laparoscópica com duas incisões (CL2i) é factível, segura e com bom resultado estético, permitindo operar utilizando apenas instrumental laparoscópico convencional, sem aumentar tempo operatório ou risco de complicações / INTRODUCTION: About 20% of the population has cholelithiasis and this is the main abdominal cause of hospitalization in developed countries. Considering that only in the United States about 700,000 cholecystectomies are done each year, it is possible to estimate the importance of the problem for public health. Decreasing the number of incisions can reduce surgical trauma and offer better aesthetic results. OBJECTIVE: To describe a two-incision laparoscopic cholecystectomy technique (TILC) using only conventional material, without increasing complications, nor operative time, offering the same safety as conventional laparoscopic cholecystectomy. METHOD: A consecutive and prospective case series, compared to another historical series operated by conventional laparoscopy cholecystectomy (LC). The TILC was performed with 3 trocars in 2 incisions, two trocars in umbilical incision and one in epigastrium. A total of 72 patients were operated on by the same surgeon (36 in each group). RESULTS: There were no significant differences between groups for gender, mean age, body mass index (BMI) or length of hospital stay. The procedures were classified by the surgeon according to surgical difficulty and there was no difference between the series (p < 0.05). There were minor complications in 5.6% (n = 2) procedures in each group. There were no differences between means of operative time (p = 0.989), which were 49 (95% CI 42 to 56) min in LC and 40 (CI 95% 35 to 44) min in TILC. There was no need for additional portals in any case, nor for conversion to open surgery. CONCLUSIONS: Two-incision laparoscopic cholecystectomy (TILC) is feasible, safe and with good aesthetic result, using the same instruments of LC, without increasing operative time or complications
9

Ovariectomia em cadelas por notes híbrida ou total: estudo de viabilidade técnica, análises álgica e de cortisol plasmático / Ovariectomy in bitches by hybrid or pure notes: techinical viability, algic and plasma cortisol concentrations study

Linhares, Marcella Teixeira 20 January 2017 (has links)
The purpose of this study was to compare two transvaginal NOTES ovariectomy (OVE) techniques in bitches regarding technical issues, surgical time, complications, as well as plasma cortisol concentration and postoperative pain scores. A sample of 16 dogs was divided into two groups: GNH patients (n=8) underwent transvaginal hybrid-NOTES OVE; and GNT dogs (n=8) were submitted to transvaginal total-NOTES OVE. The surgical time was not different between groups. None of the dogs required rescue analgesic during or after surgery at any time point. Groups did not differ significantly from each other regarding pain scores, except for 72 hours after extubation on visual analogue scale (EVA) assessment. GNH group presented higher pain score than GNT at 72 hours. Plasma cortisol did not differ between groups in most time points. However, GNT group presented higher plasma cortisol at the baseline. Cortisol peaked at the immediate postoperative period in both groups, but was significantly raised only in the GNH group. Both NOTES OVE techniques were feasible and safe in dogs. However, proper patient selection is advised. Techniques showed similar results for all assessment. Both techniques presented low complications rates and reduced pain during and after surgery. / O presente estudo busca comparar duas novas técnicas de ovariectomia (OVE) por NOTES transvaginal em cadelas quanto a viabilidade técnica, tempo cirúrgico e incidência de complicações trans e pós-operatórias, bem como quanto à concentração de cortisol plasmático e escores de dor no período pós-operatório. Para tanto, uma amostra de 16 cadelas foi separada em dois grupos, sendo os pacientes do GNH (n=8) submetidos à OVE por NOTES transvaginal híbrida e os do grupo GNT (n=8) submetidas à OVE por NOTES transvaginal total. Os tempos cirúrgicos não diferiram entre os grupos experimentais. Nenhum dos cães requereu resgate analgésico nos períodos trans ou pós-operatório. Quanto ao escore de dor, os grupos não diferiram significativamente entre si na maioria dos tempos estudados, com exceção da avaliação nas 72 horas após extubação, na escala visual analógica (EVA), onde o GNH demonstrou índices mais elevados de dor que o grupo GNT. Os valores do cortisol plasmático não diferiram entre os grupos na maioria dos tempos, exceto no basal, onde os do grupo GNT foram superiores. Os valores mais elevados de cortisol para ambos os grupos experimentais foram encontrados no pós-operatório imediato, porém considerados significativos apenas para o grupo GNH. Ambas as técnicas de NOTES propostas se mostraram viáveis e seguras na realização de OV em cadelas, desde que executadas em pacientes selecionados quanto às condições anatômicas. As duas técnicas apresentaram resultados semelhantes para os parâmetros avaliados, com baixas taxas de complicações e reduzido estímulo álgico nos períodos trans e pós-operatório.

Page generated in 0.0203 seconds