• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 119
  • 8
  • 8
  • 8
  • 8
  • 5
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 120
  • 120
  • 79
  • 66
  • 34
  • 29
  • 25
  • 24
  • 23
  • 21
  • 20
  • 17
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Efeito do condicionamento da superfície do cimento de ionômero de vidro modificado por resina e de técnicas de inserção na infiltração marginal de restaurações de resina composta / The effect of etching the surface of a resin modified glass ionomer liner and placement techniques on microleakage of resin composite restorations

Pazinatto, Flavia Bittencourt 03 April 2003 (has links)
Investigou-se a influência do condicionamento da superfície do cimento de ionômero de vidro modificado por resina e de técnicas de inserção na infiltração marginal de restaurações de resina composta. Foram confeccionadas cavidades classe V (profundidade de 1,5 mm e largura/altura de 3,0 mm) em 60 dentes bovinos, com margens totalmente em dentina coronária após lixamento do esmalte. Os dentes foram divididos em seis grupos e restaurados: Grupo A: Single Bond/Z250 (2 incrementos); Grupo B: Single Bond/Z250 (incremento único); Grupo C: Vitrebond/condicionamento com ácido fosfórico 35 % (15 seg.) do Vitrebond/Single Bond/Z250 (2 incrementos); Grupo D: Vitrebond/condicionamento com ácido fosfórico 35 % (15 seg.) do Vitrebond/Single Bond/Z250 (incremento único); Grupo E: Vitrebond/Single Bond/Z250 (2 incrementos); Grupo F: Vitrebond/Single Bond/Z250 (incremento único). O cimento de ionômero de vidro foi inserido na espessura aproximada de 0,5 mm. A inserção da resina composta foi realizada com o primeiro incremento na parede incisal. Após 7 dias, as restaurações foram acabadas e polidas com discos de granulação sequencial (Super Snap, Shofu). Em seguida, foi realizado teste de microinfiltração marginal utilizando fucsina básica a 0,5 % por 24 h. As restaurações foram seccionadas e selecionadas as secções mais infiltradas para digitalização das imagens e determinação da penetração do corante, em milímetros, por meio do programa de computação ImageTool (UTHSCSA). A análise estatística (µ = 0,05) realizada pelos testes de ANOVA a um critério, “t" de Student pareado e de Tukey, mostrou não haver diferença na infiltração total entre os grupos C, D, E e F e entre os grupos A e B. Houve diferença significante entre os grupos de restauração mista e aqueles sem o Vitrebond. Dentro de cada grupo, houve diferença significante entre as margens incisal e cervical, exceto para o grupo F. Não houve diferença significante entre as margens incisais de todos os grupos. Na parede cervical, não houve diferença entre os grupos A, B e C; C, D, E e F; e entre B, C e D. Conclui-se que, a infiltração não foi afetada pelo condicionamento do cimento de ionômero de vidro modificado por resina nem pela técnica de inserção da resina composta. / To determine the effect of resin composite placement techniques and the acid etching of the liner on the microleakage of sandwich restorations. Class V cavities were prepared at buccal surface with margins in dentin in sixty bovine incisors. Six groups of ten teeth each were restored as follow: Group A) Single Bond/Z250 (2 increments); Group B) Single Bond/Z250 (bulk insertion); Group C) Vitrebond with surface acid etching/Single Bond/Z250 (2 increments); Group D) Vitrebond with surface acid etching/Single Bond/Z250 (bulk insertion); Group E) Vitrebond/Single Bond/Z250 (2 increments); Group F) Vitrebond/Single Bond/Z250 (bulk insertion). Vitrebond was inserted with thickness of 0.5 mm. The first resin composite increment was placed at incisal margin. After restorations, the teeth were imersed in aqueous solution of 0.5 % basic fuchsin for 24 h. The samples were sectioned and dye penetration were measured in milimeters by using a computer program (ImageTool, UTHSCSA). Data were analyzed by one-way ANOVA, paired "t" test and Tukey test (µ = 0.05). There were no statistical difference on the total microleakage between groups A and B, neither the groups C, D, E and F. Significant difference were shown between groups with resin modified glass ionomer liner and those without. There were significant difference between incisal and gingival margins for all the groups, except for group F. There were no significant difference among incisal margins. At gingival margins, there were no difference among groups A, B and C; B, C and D; and C, D, E and F. It can be concluded that neither surface acid etching of Vitrebond nor placement techniques of resin composite affected Class V microleakage. Sandwich restorations may lead to less microleakage in dentin cavities than resin composite restorations.
52

Influência do tratamento de superfície na infiltração marginal de reparos em porcelana /

Mello, Elson Braga de. January 2001 (has links)
Orientador: Regina Célia Santos Pinto Silva / Banca: Luis Alexandre Maffei Santini Paulino / Banca: Eduardo Shigueyuki Uemura / Mestre
53

Avaliação dos métodos para análise da microinfiltração marginal em restaurações de resina composta classe V in vitro / The methods evaluation for marginal microleakage analysis in class V resin composite restorations in vitro

Laísa Araujo Cortines Laxe 18 December 2009 (has links)
O objetivo deste estudo foi comparar os resultados da microinfiltração marginal obtidos por diferentes meios de aquisição de imagens e métodos de mensuração da penetração de prata em restaurações de resina composta classe V, in vitro. Dezoito pré-molares humanos hígidos, recém extraídos, foram divididos em três grupos, de acordo com o tipo de instrumento para preparação cavitária utilizado. Grupo 1: ponta diamantada número 3100, em alta rotação. Grupo 2: broca carbide número 330, em alta rotação. Grupo 3: ponta CVDentus código 82137, em aparelho de ultrassom. Foram realizados preparos cavitários padronizados (3x4x2mm) classe V nas faces vestibular e lingual de todos os dentes, com margens oclusais em esmalte e cervicais em dentina/cemento. As cavidades foram restauradas com o sistema adesivo Solobond M (VOCO) e resina composta Grandio (VOCO), a qual foi inserida e fotoativada em três incrementos. Os corpos de prova ficaram imersos em água destilada por 24h a 37oC; receberam acabamento e polimento com discos SofLex (3M) e foram novamente armazenados em água destilada, por sete dias. Posteriormente, as superfícies dentárias foram coberta com duas camadas de esmalte para unhas vermelho, exceto as áreas adjacentes às restaurações. Os espécimes ficaram imersos em solução aquosa de nitrato de prata a 50% por 24h e em solução fotorreveladora por 2h e foram seccionados no sentido vestíbulo-lingual, passando pelo centro das restaurações, com disco diamantado em baixa rotação. As amostras foram polidas em politriz horizontal e analisadas por diferentes métodos. À extensão da microinfiltração foi atribuído escores de 0 a 3 através de análises por meio de estereomicroscópio tradicional e com leds e microscópio ótico. As imagens obtidas na lupa com leds e no microscópio ótico tiveram as áreas infiltradas medidas através do software AxioVision. O teste &#967;2 de McNemar-Bowker revelou concordância estatística entre estereomicroscópio tradicional e o com leds (p=0,809) durante análises semiquantitativas. Porém, houve diferenças significantes entre microscópio ótico e estereomicroscópios (p<0,001). Houve boa correlação entre análises semiquantitativas e quantitativas de acordo com o teste de Spearmann (p<0,001). O teste de Kruskall-Wallis não revelou diferenças estatisticamente significantes (p=0,174) entre os grupos experimentais na análise quantitativa por microscópio ótico, em esmalte. Ao contrário do que se observa com a mesma em lupa (p<0,001). Conclui-se que o método de atribuição de escores comumente aplicado com a lupa nos estudos da microinfiltração marginal é uma opção confiável para análise da microinfiltração. / The aim of this study is compare the results of marginal microleakage got through different images acquiring methods and measuring methods related to silver leakage in class V resin composite restorations, in vitro. Eighteen intact human pre-molars were divided into three groups, according to the instruments for cavity preparation: 1- diamond tip, number 3100, in a turbine of high-speed; 2- carbide bur, number 330, in a turbine of high-speed; and 3- diamond tip (CVD), number 82137, coupled with an ultra-sound device. Class V cavities were prepared on buccal and lingual surfaces of the teeth, with occlusal margins in enamel and gingival margins in dentin. The cavities were treated with adhesive Solobond M (VOCO) and restored with composite Grandio (VOCO) through incremental technique. The samples were stored for 24h at 37oC in water, finished and polished with Soflex (3M) discs and stocked in water at 37oC for a week. Then, the surrounding tooth surfaces were coated with nail varnish, except in the areas adjacent to the restorations. The samples were immersed in a 50% solution of silver nitrate for 24h, exposed to photodeveloping solution for 2h, and cut in the buccal-lingual direction on restoration center. These sections were polished and the extent of microleakage was ranked using a 0-3 scale through tradicional stereomicroscope, with leds one and optical microscope. The images obtained through these latest devices had its leakage area measured with aid of AxioVision software. The &#967;2 McNemar-Bowker test revealed statistical agreement between tradicional stereomicroscope and with leds one (p=0,809) during semiquantitative analysis, but there were significant differences between optical microscope and stereomicroscopes (p<0,001). There were good correlation between semiquantitatives and quantitatives analysis according to Spearmanns test (p<0,001). The Kruskall-Wallis test showed no statistically significant difference (p=0,174) between three experimental groups in quantitative analyse with optical microscope in enamel margins. Although there was less microleakage statistically significant in group 2 comparing with group 1 in quantitative analyse with stereomicroscope. On dentin margins there were not differences between experimental groups in the results of microleakage obtained with all methods for analysis. Finally, the method of ranked scores used in microleakage studies frequently with stereomicroscopes, is a security option for analysis of the microleakage.
54

Avaliação da microinfiltração marginal em cavidades classe II de molares decíduos restauradas com diferentes cimentos de ionômero de vidro / Evaluation of marginal microleakage in class II cavities of primary molars restored with different glass ionomer cements

Marlus Roberto Rodrigues Cajazeira 26 February 2008 (has links)
O objetivo desta pesquisa foi avaliar a microinfiltração em restaurações classe II realizadas com diferentes cimentos de ionômero de vidros em molares decíduos. Para tal, foram selecionados quarenta molares decíduos humanos a partir de um Banco de Dentes. Nas faces mesial e distal de cada dente foram preparadas cavidades classe II com dimensões padronizadas. Em seguida, os dentes foram divididos em oito grupos experimentais correspondentes ao material restaurador utilizado: grupo MXR (Maxxion R); grupo VDR (Vidrion R); grupo VTR (Vitremer); grupo VTF (Vitro Fill LC); grupo FUJ (Fuji IX); grupo KTM (Ketac Molar); grupo VMO (Vitro Molar); grupo MGS (Magic Glass ART). Ao término de vinte e quatro horas de imersão em água destilada, os dentes foram mantidos em solução de nitrato de prata a 50% pelo mesmo período e, então, em solução reveladora de radiografias (hidroquinona, Kodak) por quinze minutos. Os dentes foram então seccionados através do centro das restaurações, e observados em lupa estereoscópica sob o aumento de quarenta vezes. A microinfiltração foi graduada co base em escores relacionados à penetração do nitrato de prata na interface adesiva. Os resultados, após submetidos à análise estatística, demonstraram que nenhum dos materiais testados impediu completamente a microinfiltração. No entanto, o Vitremer apresentou os escores mais baixos, seguido do Ketac Molar e do Fuji IX. Os materiais Magic Glass ART, Vitro Molar, Vitro Fill LC e Vidrion R apresentaram comportamento intermediário em relação aos demais, enquanto o Maxxion R apresentou os piores resultados. Com base na metodologia empregada e nos resultados obtidos, pode-se concluir que nenhum dos materiais testados foi capaz de impedir completamente a microinfiltração, apesar de apresentarem graus varáveis de suscetibilidade a esse fenômeno, destacando-se, entre eles o Vitremer, o Ketac Molar e o Fuji IX por apresentarem baixos níveis de microinfiltração, seguidos do Magic Glass ART, Vitro Molar, Vitro Fill LC e Vidrion R. Em contrapartida, o Maxxion R apresentou os piores resultados, fato constatado pelos altos escores de microinfiltração registrados. / The aim of this study was to evaluate the microleakage in class II glass ionomer cement restorations in primary molars. For this, were selected fourty primary molars in a human teeth bank. At mesial and distal surfaces of the teeth were prepared standard class II cavities. In sequence, the teeth were subdivided in eight experimental groups in according with the restorative material used: group MXR (Maxxion R); group VDR (Vidrion R); group VTR (Vitremer); group VTF (Vitro Fill LC); group FUJ (Fuji IX); group KTM (Ketac Molar); group VMO (Vitro Molar); group MGS (Magic Glass ART). After past twently four hours in immersing water, the restored teeth were immersed in a 50% solution of silver nitrate for similar period, and, then, in radiographic solution (hydroquinone, Kodak) for fiteen minutes. The teeth were sectioned at the center of restorations, and observed at stereoscope under forty-fold increase. The microleakage was graduated in scores related with the grade of silver nitrate penetration at the adhesive interface. The results, after submitted statistical analysis, showed that none of the materials impeded completely the microleakage. Thus, Vitremer showed the minor scores, followed by Ketac Molar and Fuji IX. The materials, Magic Glass ART, Vitro Molar, Vitro Fill LC and Vidrion R showed intermediary results, while Maxxion R showed the worse ones. Based in methodology used in this study and in their results, its possible concluded that none of the materials was able to impede the microleakage, although presented variable grades susceptibility of this phenomenom, with emphasis to Vitremer, Ketac Molar and Fuji IX because presented minor microleakage, following Magic Glass ART, Vitro Molar, Vitro Fill LC and Vidrion R. On the other hand, Maxxion R presented the worse results, fact confirmed by high microleakage scores observed.
55

Resistência à infiltração de glicose de quatro cimentos reparadores / Glucose leakage resistance of four repair cements

Fernanda de Souza Leal Fonseca 26 January 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo teve como objetivo comparar a qualidade do selamento promovido por 3 cimentos reparadores endodônticos: Ceramicrete, iRoot-BP Plus e BioAggregate, com o ProRoot MTA branco, utilizando o modelo de infiltração de glicose sob pressão. 64 incisivos centrais superiores, recém-extraídos e sem tratamento endodôntico foram selecionados. A instrumentação do canal radicular foi realizada em todos os dentes com brocas Gates-Glidden e limas K-Flexofile (Dentsply Maillefer, Ballaigues Suíça), 1mm aquém do ápice. A patência foraminal foi confirmada a cada instrumento usado. Os dentes tiveram suas coroas removidas padronizando-os em 15mm de comprimento. Foi realizada apicetomia a 3mm do ápice e o preparo da cavidade retrógrada com o auxílio do ultrassom Various 350 (NSKNakanishi Inc., Tóquio, Japão) e da ponta E32D (NSKNakanishi Inc., Tóquio, Japão). As raízes foram distribuídas, randomicamente, em quatro grupos experimentais (n=15): G1Ceramicrete, G2iRoot BP Plus, G3BioAggregate e G4ProRoot MTA branco. Como controle negativo (n=2) foram utilizados dentes hígidos, e como controle positivo (n=2), dentes acessados e com patência confirmada. Os cimentos reparadores foram manipulados seguindo as recomendações do fabricante e inseridos na cavidade retrógrada utilizando a mesma ponta ultrassônica usada no preparo. As amostras foram mantidas na presença de umidade por 72h para o completo endurecimento dos materiais. As raízes foram montadas em um dispositivo de dupla-câmara selada para a infiltração da glicose. Foram utilizados 0,75ml de solução de glicose a 1Mol/L na câmara superior e 0,75ml de água destilada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão, que permitiu a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15psi durante 1 hora. Uma alíquota de 10l foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada com o auxílio do Kit GlucoseHK (Megazyme, Wicklow, Irlanda) e de um espectrofotômetro de luz visível (Campsec M330, Cambridge, Reino Unido) em um comprimento de onda de 340nm. O teste não-paramétrico Kruskal-Wallis e o teste Dunns foram utilizados na análise estatística. Os resultados encontrados demonstraram que houve diferença significativa entre os grupos experimentais (p=0,0036). O BioAggregate apresentou a maior concentração de glicose-1,85(g/L), seguido do ProRoot MTA-1,2; IRoot BP-0,85 e Ceramicrete-0,75. Não houve diferença entre os três novos cimentos reparadores e o material padrão-ouro (p>0,05). Não houve diferença entre Ceramicrete e iRoot BP Plus (p>0,05), porém estes foram estatisticamente diferentes do BioAggregate (p<0,05). Diante dos resultados obtidos, pode-se concluir que: nenhum dos cimentos testados foi capaz de promover selamento hermético; os três novos cimentos testados não revelaram o mesmo padrão de selamento; os três novos cimentos testados revelaram um padrão de selamento semelhante a do ProRoot MTA branco; e o Ceramicrete e o iRoot BP Plus apresentaram padrão de selamento superior em comparação com o BioAggregate. / The present study sought to compare the sealing ability of three new reparative endodontic cements Ceramicrete, iRoot-BP Plus, BioAggregate and compared to white ProRoot MTA, using the glucose leakage model under pressure. Sixty-four recently extracted maxillary incisors, without previous endodontic treatment, were selected. A crown-down root canal instrumentation was performed using Gates-Glidden burns and Kerr Flexofile (Dentsply Maillefer, Ballaigues Switzerland), 1mm short of the apical foramen (working length). The apical patency was confirmed after the use of each instrument, with a Kerr file #10, 1mm beyond the foramen. The teeth had their crowns removed, leaving roots 15mm in length. After that, apicetomy was carried out at 3mm from the apex. The retrograde preparation was performed using the E32D ultrasonic tip (NSK Nakanishi Inc., Tokyo, Japan). Roots were randomly distributed in four experimental groups (n=15): G1 - Ceramicrete, G2 - iRoot BP Plus, G3 - BioAggregate and G4 - white ProRoot MTA as gold-standard for comparisons. For the negative control group (n=2) teeth with intact crowns were used, and for the positive control (n=2), teeth with access and apical patency. The root-end filling material was manipulated as recommended by the manufacturer and inserted into the retrograde cavity using the same ultrasonic tip. The samples were stored at 100% humidity for three days to allow setting of the material. After that, the roots were mounted in a double-chamber apparatus where 0,75ml of 1Mol/L glucose solution was placed into the superior chamber and 0,75ml of distilled water was placed into the inferior chamber. The devices were connected to a pressure distribution system that was developed to allow the leakage of 32 samples at a single stage. The glucose solution was forced apically under a pressure of 15psi during 1 hour. A sample of 10l was taken from the inferior chamber and the glucose concentration was measured following an enzymatic reaction using the Glucose HK Kit (Megazyme, Wicklow, Ireland) and a spectrophotometer (Campsec M 330, Cambridge, UK) at a wave-length of 340nm. The Kruskal-Wallis and the Dunns test were used for statistical analyses. The results demonstrated that there was significant difference between experimental groups (p=0,0036). BioAggregate displayed the highest glucose concentration - 1.85(g/L), followed by ProRoot MTA - 1.2; iRoot BP Plus - 0.85; Ceramicrete - 0.75. No significant difference was observed between the three new reparative cements and the gold-standard (p>0.05). There was no difference between Ceramicrete and iRoot BP Plus (p>0.05), however both materials were significantly different fromBioAggregate (p<0.05). Considering the results, it can be concluded that none of the tested cements was able to prevent glucose leakage, the 3 new tested cements do not presented a similar quality of sealing, and the three new tested cements presented a similar sealing pattern of ProRoot MTA and both Ceramicrete and iRoot BP Plus presented better quality of sealing than BioAggregate.
56

Análise morfológica de cones de guta-percha submetidos a diferentes tratamentos de desinfecção e sua influência na microinfiltração /

Rosa, Patrícia Campos Ferreira da. January 2011 (has links)
Orientador: Simone Helena Gonçalves de Oliveira / Banca: Carlos Henrique Ribeiro Camargo / Banca: Brenda Paula Figueiredo de Almeida Gomes / Resumo: Os cones de guta-percha precisam passar por um processo de desinfecção química rápida antes da obturação. Algumas soluções são capazes de agir em 1 minuto, mas se este período de imersão for prolongado, alterações podem ser causadas na estandardização dos cones, dificultando a adaptação ao canal radicular. Essa pesquisa avaliou as alterações morfológicas, em microscopia eletrônica de varredura (MEV), que ocorrem na superfície dos cones de guta-percha em períodos excedidos aos preconizados. Clorexidina 2% (CLX), hipoclorito de sódio 2,5% (NaOCL), ácido peracético 2% (AP) e solução de ácido peracético 0,25% (SAP) foram as soluções utilizadas nos períodos de 1 minuto, 30 minutos, 6 horas e 12 horas. Os grupos foram divididos de acordo com a solução e período de desinfecção (n=12). Os resultados indicaram que houve diferença estatística significante entre as soluções e períodos testados. Em 1 minuto, todas as soluções não diferiram do controle. Após 30 minutos, a SAP alterou significativamente a morfologia dos cones. O teste de espectrometria de energia dispersiva (EDS) indicou que todas as substâncias e períodos alteram a composição química dos cones de gutapercha. A relação da desinfecção na microinfiltração da obturação também foi avaliada nos grupos que sofreram desinfecção por 12 horas. O grupo da SAP apresentou diferença estatística significante em relação ao controle, pois 100% das suas raízes apresentaram infiltração. Os demais grupos da CLX, NaOCL e AP, embora sem diferença estatística significante, tiveram respectivamente 9, 8 e 8 do total de 12 das suas raízes com infiltração. Conclui-se que o processo de desinfecção pode causar alterações morfológicas se o período de imersão for excedido e que, além de alterarem a composição química dos cones de guta-percha, estas soluções podem influenciar no selamento da obturação / Abstract: The gutta-percha points must go through a fast chemical disinfection process before obturation. Some solutions are able to work in 1 minute, but if this immersion period is prolonged, changes can be caused on the points standardization, hampering the adaptation to root canal. This study evaluated the morphological changes, in scanning electron microscopy (SEM), which occur on the surface of gutta-percha points in periods beyond the recommended. 2% chlorhexidine (CLX), 2.5% sodium hypochlorite (NaOCl), 2% peracetic acid (PA) and peracetic acid solution 0.25% (PAS) were used for 1 minute, 30 minutes, 6 hours and 12 hours. The groups were divided according to disinfecting solution and period (n = 12). The results indicated a statistically significant difference between the solutions and periods tested. In one minute, none of the solutions differed from control. After 30 minutes, PAS has significantly changed the morphology of the points. The energy dispersive x-ray test (EDS) showed that all substances and periods, alter the chemical composition of the gutta-percha points. The ratio of the disinfection on microleakage of the filling was also evaluated. The SAP 12 hours group had a statistically significant difference compared to the control and the other groups, since 100% of their roots showed infiltration. Groups of 12 hours period of CHX, NaOCl and PA, although without significant difference, had respectively 9, 8 and 8 out of 12 of its roots with infiltration. It is concluded that the disinfection process can cause morphological changes if the immersion period is exceeded and that, besides altering the chemical composition of gutta-percha points, these solutions can influence on the hermetic sealing of the root canal / Mestre
57

Material obturador de canal radicular à base de uretano metacrilato : estudo histológico e da infiltração coronária em dentes de cães /

Avendaño Rueda, Julio César. January 2006 (has links)
Orientador: Léa Assed Bezerra da Silva / Resumo: O objetivo deste estudo foi o de avaliar a biocompatibilidade e a infiltração no sentido coroa/ápice de um cimento obturador de canais radiculares à base de uretano dimetacrilato denominado Endo-Rez. Foram utilizados 56 canais radiculares de dentes de cães, os quais foram divididos em 4 grupos experimentais: Grupo I, Endo-Rez com restauração coronária (18 raízes); Grupo II, Sealapex com restauração coronária (10 raízes); Grupo III, Endo-Rez sem restauração coronária (18 raízes) e Grupo IV, canais radiculares obturados com Sealapex sem restauração coronária (10 raízes). Os canais radiculares foram instrumentados pela técnica clássica e obturados pela técnica de condensação lateral ativa (Grupo II e IV) e técnica de cone único (Grupo I e III). Decorridos 90 dias, os animais foram mortos e as peças submetidas ao processamento histológico. A avaliação histopatológica mostrou que os grupos I e III que foram obturados com Endo-Rez com e sem restauração coronária respectivamente, apresentaram semelhante infiltrado inflamatório periapical crônico de grau moderado/severo, severo aumento do espaço periodontal apical e ausência de selamento biológico apical. O grupo IV, obturado com Sealapex, aberto ao meio bucal por 90 dias, apresentou características histopatológicas similares aos grupos I e III. O Grupo II, cujos canais radiculares foram obturados com o Sealapex com restauração coronária ocorreu infiltrado inflamatório moderado e espessamento do espaço periodontal apical predominantemente leve, na maioria dos espécimes, exibindo selamento apical biológico em apenas 1 caso, portanto 10% dos espécimes. / Abstract: The aim of this study was to evaluate in vivo the biocompatibility and coronal leakage of a new urethane metacrylate resin-based sealer, EndoRez. Sixty root canals of dog's teeth were divided into four experimental groups. Group I and III, EndoRez with and without coronal obturation respectively, Group II and IV Sealapex with and without coronal obturation respectively. The teeth were instrumented with a classic technique with Groups II and IV filled by the lateral condensation active technique with gutta percha points, while groups I and III were filled by the single cone technique. After 90 days, the animals were killed and specimens prepared histopathologically. The histopathological evaluation showed in the Groups I and III filled with EndoRez and the Group IV filled with Sealapex, most specimens with severe and moderate chronic inflammatory infiltrate, severe thickness of periodontal ligament and the apical sealing absence, Whereas, in Group II filled with Sealapex, most specimens showed mild and moderate inflammatory infiltrate, less thickness of periodontal ligament, and 30% exhibit biological apical sealing. / Mestre
58

Infiltração marginal em cavidades de classe V. Efeito de sistema adesivo e preparo cavitário /

Araújo, Taylane Soffener Berlanga de. January 2005 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Edson Alves de Campos / Banca: Luís Alberto Plácido Penna / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Resumo: Este estudo teve por objetivo analisar in vitro a influência de dois sistemas adesivos resinosos, sendo um autocondicionante de dois passos (Clearfil SE Bond 2) e um convencional também de dois passos (Master Bond), bem como o tratamento das margens cavitárias no controle da microinfiltração marginal. Preparos cavitários de classe V foram executados na face vestibular em 80 dentes anteriores bovinos previamente extraídos, divididos em oito grupos (n=10). O grau de infiltração marginal foi avaliado por penetração do agente traçador (Nitrato de Prata (AgNO3) a 50%) nas paredes incisal e cervical por meio de um "Software-Image Tool", no qual se mede o grau de infiltração em micrômetros e, portanto, análise quantitativa, os resultados submetidos à Análise de Variância seguida do teste de Tukey para observação das diferenças, concluindo-se que: a) os sistemas adesivos apresentaram estatisticamente o mesmo comportamento; b) existe diferença estatisticamente significante entre as técnicas de preparos utilizados sendo que os preparos realizados nos Grupo I e Grupo II, bem como nos Grupos VII e VIII, apresentaram comportamento semelhante e os melhores resultados para redução da microinfiltração; c) os preparos do Grupo III e Grupo IV apresentaram maiores índices de microinfiltração marginal, no entanto, semelhantes aos Grupos V e VI; d) a região cervical apresentou maior nível de microinfiltração quando comparada com a região incisal. / Abstract: This study aimed to analyse in vitro the influence of two resinous adhesive systems: one self-etching of two steps (Clearfil SE Bond 2) and one also conventional of two steps (Master Bond), as well as the treatment of the cavity margins in the marginal microleakage control. Cavity preparations of class V were carried out on the buccal surface of 80 bovine anterior teeth, previously extracted, divided into eight groups (n=10). The marginal leakage degree was evaluated by the penetration of the tracer agent (Silver Nitrate (AgNO3) at 50%); on the incisor and cervical walls through a Software-Image Tool that measures the leakage degree in micrometers and, therefore, quantitative analysis, which results were subjected to the Variance Analysis and afterwards to the Tukey's test in order to observe the differences it was possible to conclude that: a) the adhesive systems presented statistically the same behaviour; b) there is a statistically meaningful difference between the preparation techniques that were used and the preparations that were carried out in Group I and Group II, as well as Groups VII and VIII, that presented similar behaviour and the best results for the reduction of microleakage; c) the preparations of Group III and Group IV presented higher rates of marginal microleakage, however, they were similar to Groups V and VI; d) the cervical region presented higher level of microleakage comparing to the incisor region. / Doutor
59

Resistência de três materiais retrobturadores frente à infiltração microbiana por Enterococcus faecalis / Resistance of three root-end filling materials in teeth submitted to the microbial leakage by Enterococcus faecalis

Marcio Salles Ferreira 13 December 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi comparar a capacidade de selamento apical de três materiais retrobturadores em dentes submetidos à infiltração microbiana por Enterococcus faecalis. Além de analisar a ocorrência da infiltração microbiana em relação à variável tempo. Para tal, foram utilizados 45 incisivos superiores permanentes humanos extraídos, instrumentados com o sistema rotatório ProTaper Universal (MAILLEFER) e obturados pela técnica Híbrida de Tagger, com cimento endodôntico: AH Plus (DENTSPLY). A apicetomia foi realizada com a remoção de 3mm do terço apical e o retropreparo confeccionado com pontas ultrasônicas. As amostras foram subdivididas, aleatoriamente, em três grupos com 15 dentes cada, e dois grupos controles. Os materiais utilizados para a retrobturação foram MTA branco (ANGELUS), Sealer 26 (Dentsply), Palacos-R (HERAEUS KULZER). Foram confeccionados dispositivos para fixação dos dentes aos tubos Eppendorfs. As amostras foram inoculadas com cepas de E. faecalis e incubadas a 37C, por um período de 60 dias, para análise da presença de turvação do meio Enterococosel. Para a realização da análise estatística foram utilizados os seguintes testes: Quiquadrado pela correção de Yates, Prova Exata de Fisher e pela curva de sobrevivência com os testes Mantel-Cox e o Gehan-Breslow-Wilcoxon. Os resultados mostraram que todos os grupos nos quais foi realizada a obturação e a posterior retrobturação apresentaram infiltração. Comparando todos os grupos, houve diferença significativa entre o Palacos-R e o Sealer 26. Mas não houve diferença significativa entre o Palacos-R e o MTA e nem do MTA com o Sealer 26. Em relação aos materiais retrobturadores, o Palacos-R obteve a menor infiltração, seguido do MTA branco e do Sealer 26. / The objective of this study was to compare the apical sealing ability of three root-end filling materials in teeth submitted to the microbial leakage by Enterococcus faecalis. Besides analyzing the occurrence of the microbial leakage in relation to the variable time.For such, 45 incisiv permanent superior teeth extracted from humans were used, which were instrumented with ProTaper Universal system (MAILLEFER) and filled by the Hybrid of Tagger compaction technique, with endodontic sealer: AH Plus (DENTSPLY). The apices were resected with the removal of 3mm of the apical third and the root-end cavities prepared with ultrasonic tips. The samples were subdivided, randomly, in three groups with 15 teeth each, and two control groups. The materials used for the retrofilling were white MTA (ANGELUS), Sealer26 (DENTSPLY), Palacos-R (HERAEUS KULZER). Devices were made for fixation of the teeth to the Eppendorf tubes. The filling samples were inoculated with strains of E. faecalis and incubated at 37C, for a period of 30 days, for analysis of the presence of turbidity of Enterococosel medium. For the accomplishment of the statistical analysis the following tests were used: Quisquare by Yates correction, Fisher Exact Test and survival curve testing Mantel-Cox and the Gehan-Breslow-Wilcoxon. The results showed that all the groups in which the filling was accomplished and the subsequent retrofilling presented leakage. Comparing all the groups, it had significant difference between the Palacos-R and Sealer 26. But it did not have significant difference between the Palacos-R and the MTA and nor of the MTA with Sealer 26. In regard to only the root-end filling materials, Palacos-R obtained the smallest leakage, followed by white MTA and Sealer26.
60

Infiltração microbiana por Enterococcus faecalis em canais retrobturados com MTA, iRoot SP e Endo CPM Sealer / Microbial leakage by Enterococcus faecalis in root retrofilling with MTA, iRoot SP and Endo COM Sealer

Viviane Dias Martini Alves Nascimento 16 December 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O objetivo deste trabalho consistiu na análise da infiltração apical em dentes retrobturados por três materiais: MTA, iROOT SP e Endo CPM Sealer. Para tal, foram utilizados 51 dentes humanos extraídos, incisivos centrais superiores, que foram instrumentados manualmente com limas tipo K, pela técnica Crown-down, obturados com compactação lateral e, após serem apicectomizados a 3mm aquém do ápice foram submetidos à retrobturação, com os três materiais propostos. As amostras foram divididas, randomicamente, em três grupos: GI MTA, GII iROOT SP e GIII Endo CPM Sealer, cada grupo com 15 amostras. Os dentes foram inseridos em tubos de eppendorfs, e feitos a impermeabilização do remanescente radicular utilizando duas camadas de cianocrilato, epóxi, e outra camada de esmalte. Em cada eppendorf foi adicionado caldo TSB estéril e uma suspensão de Enterococcos faecalis e adaptado ao frasco de vidro com meio de cultura enterococcosel. A infiltração bacteriana foi verificada pela turvação do meio de cultura. Após a análise no período de 60 dias, podemos concluir que durante esse tempo ocorreram infiltrações no Grupo I, 43,75 % das amostras apresentaram turvamento do meio de cultura demonstrando persistência da infecção. Já no Grupo II, 31,25 % das amostras tiveram crescimento bacteriano. Por fim no Grupo III, 25,00 % houve a infiltração. Grupos controle positivo e negativo para crescimento bacteriano foram realizados (n=3, cada). Os cimentos testados comportaram-se de maneira semelhante frente à infiltração bacteriana durante o período testado. / The objective of this study consisted in the analysis of apical leakage in retrofilled teeth by three materials: MTA, iROOT SP and Endo CPM Sealer. 51 extracted human central incisors were instrumented manually with K-type files by Crown-down technique, filled by lateral compactation and apicectomyzed to 3mm below the apex. Then, teeth were retrofilling with the three proposed materials. The samples were divided, randomly, in three groups: GI - MTA, GII - iROOT SP and GIII - Endo CPM Sealer, each group with 15 samples. Teeth were inserted into eppendorf tubes, and the remaining root were sealed using two layers of cyanoacrylate, epoxy, and another layer of nail varnish. In each eppendorf tube were added sterile TSB broth and a suspension of Enterococcos faecalis. The body proof was adapted to a glass bottle with culture medium Enterococcosel. The bacterial leakage was checked by turbidity of the culture medium. After analysis within 60 days the bacterial leakage was recorded: the Group I showed infiltration in 43.75% of body proof, the Group II in 31.25% and Group III 25%. Positive and negative control groups for bacterial growth were performed (n = 3, each). We can conclude that the tested cements behave similarly to bacterial infiltration front during the period tested.

Page generated in 0.2845 seconds