• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 119
  • 8
  • 8
  • 8
  • 8
  • 5
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 120
  • 120
  • 79
  • 66
  • 34
  • 29
  • 25
  • 24
  • 23
  • 21
  • 20
  • 17
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da influência da remoção da smear layer na infiltração apical = Evalution of the influence of smear layer removal on the apical leakage / Camila Paiva Perin ; orientador, Ulisses Xavier da Silva Neto / Evalution of the influence of smear layer removal on the apical leakage

Perin, Camila Paiva January 2009 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2009 / Inclui bibliografias / O objetivo deste estudo foi analisar a influência de diferentes agentes irrigadores (hipoclorito de sódio isoladamente, hipoclorito de sódio + EDTA, hipoclorito de sódio + BioPure MTAD) utilizados para remoção da smear layer, na infiltração apical. Quaren / Objective. The aim of this study was to evaluate the influence of different irrigant agents (sodium hypochlorite only, sodium hypochlorite + EDTA and sodium hypochlorite + BioPure MTAD) for smear layer removal, on apical leakage. Study design. Three group
22

Comparação da infiltração apical entre canais obturados com guta-percha/AH Plus e o sistema Resilon/Epiphany quando submetidos a duas técnicas de obturação / Comparison of apical leakage between canals filled with gutta-percha/AH Plus and the Resilon/Epiphany System, when submitted to two filling techniques

Veríssimo, Denusa Moreira January 2007 (has links)
VERÍSSIMO, Denusa Moreira. Comparação da infiltração apical entre canais obturados com guta-percha/AH Plus e o sistema Resilon/Epiphany quando submetidos a duas técnicas de obturação. 2007. 109 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2007. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-08T11:54:38Z No. of bitstreams: 1 2007_dis_dmveríssimo.pdf: 4142487 bytes, checksum: 55bbe546b889dd8b2532100208b590cf (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-01T12:43:40Z (GMT) No. of bitstreams: 1 2007_dis_dmveríssimo.pdf: 4142487 bytes, checksum: 55bbe546b889dd8b2532100208b590cf (MD5) / Made available in DSpace on 2012-02-01T12:43:40Z (GMT). No. of bitstreams: 1 2007_dis_dmveríssimo.pdf: 4142487 bytes, checksum: 55bbe546b889dd8b2532100208b590cf (MD5) Previous issue date: 2007 / The purpose of this study was to compare the level of apical leakage between canals filled with gutta-percha/AH Plus (GP) and the Resilon/Epiphany System (RES), when submitted to two filling techniques, and to observe, through the use of Optic Microscopy (OM), the adaptation of these materials to the dentinal walls in carried through transversal cuts to 4 mm of the apex. For the evaluation of leakage, seventy extracted human teeth were instrumented and randomly divided into 4 experimental groups in accordance with the material and technique used (lateral condensation and Hybrid technique - HT), and two control groups (positive and negative). After 7 days in an oven (37° C, humidity of 100%), the teeth were immersed in Indian ink and cleared. Leakage was measured by the NIH imageJ program. The exact Fisher test was used to make the comparison between the non-leakage percentages and the non-parametric Mann-Whitney test to measure the leakage when there was any. The value p<0.05 was considered to be statistically significant. With regard to the presence of leakage, there was no difference between the filling techniques (p>0.05), but there was a statistically significant difference when RES was compared with GP (p<0.05), which leaked more than RES. With RES, leakage was confined to the apical third and HT could be used to thermo-plasticize RES with satisfactory results. It was observed through the analysis in OM of 20 remaining teeth, filled in the same way that the experimental groups (5 teeth for each group), that the RES presented many areas mismatch between the material and the dentinal walls, what it would justify occurred leaking with this material. / O propósito deste estudo in vitro foi comparar o nível de infiltração apical entre guta-percha/AH Plus (GP) e Sistema Resilon/Epiphany (SRE) quando submetidos a duas técnicas de obturação, e observar, através do uso de Microscopia Óptica (MO), a adaptação destes materiais às paredes dentinárias em cortes transversais realizados a 4mm do ápice. Para a avaliação da infiltração, 70 raízes de dentes humanos extraídos foram instrumentadas e divididas aleatoriamente em quatro grupos experimentais de acordo com o material e técnica empregados (condensação lateral e técnica Híbrida-TH) e dois grupos controles (positivo e negativo). Após sete dias em estufa (37°C, umidade de 100%), as raízes foram imersas em tinta nanquim (7 dias) e diafanizadas. A infiltração linear foi medida através do programa NIH imageJ. Utilizou-se o teste exato de Fisher, para a comparação entre percentual de não-infiltração e teste não-paramétrico de Mann-Whitney, para testar o comprimento de infiltração, quando esta existiu. O valor de p<0,05 foi considerado ser estatisticamente significante. Na presença de infiltração, não houve diferença entre as técnicas de obturação empregadas (p>0,05), mas houve diferença estatisticamente significante quando o SRE foi comparado à GP (p<0,05), que apresentou maior infiltração. Concluiu-se que a infiltração com o SRE ficou confinada ao terço apical e a TH pode ser utilizada para termoplastificação do SRE com resultados satisfatórios. Observou-se através da análise em MO dos 20 dentes restantes, obturados da mesma forma que os grupos experimentais (cinco dentes para cada grupo), que o SRE apresentou muitas áreas de desadaptação entre o material e as paredes dentinárias, fato que justificaria a infiltração ocorrida com esse material.
23

Nanoinfiltração e manchamento superficial de facetas diretas de resina composta

Diaz, Sheila Francesca Rabanal January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2017. / Made available in DSpace on 2017-05-31T14:18:09Z (GMT). No. of bitstreams: 1 345988.pdf: 3518006 bytes, checksum: 67aafb150b62a10d71aaf83c5bbc7225 (MD5) Previous issue date: 2017 / O objetivo do presente estudo in vitro foi comparar a adaptação em esmalte e dentina, o selamento marginal e o nível de manchamento superficial de 2 resinas compostas de diferentes percentuais de contração de polimerização (Charisma Diamond e Filtek Z350) em facetas diretas de resina composta depois de serem submetidas a pigmentação extrínseca e ciclagem térmica. Trinta e dois incisivos inferiores, preparados para receber facetas diretas de resina composta foram divididos aleatoriamente em 4 grupos (n= 8): os Grupos 1 e 3 foram restaurados com resina composta nanohíbrida de baixa contraçao de polimerizaçao e os grupos 2 e 4 foram restaurados com resina composta nanoparticulada (com contraçao de polimerizaçao normal). Com o objetivo de avaliar o nível de manchamento superficial, os Grupos 1 e 2 foram armazenados em vinho tinto por 14 dias a 37°C e foram registrados fotograficamente antes e após a pigmentação extrínseca. Os registros fotográficos foram anexados a questionários de avaliação, submetidos a 2 examinadores voluntários (cirurgiões-dentistas). A seguir, os espécimes dos 4 grupos foram submetidos a 5.000 ciclos térmicos, a nanoinfiltração foi observada usando microscopia eletrônica de varredura (MEV), no modo retroespalhado e com espectometria de energia dispersiva. a percentagem de nanoinfiltração de partículas de prata na interface dente/restauração foi calculada usando um programa de análise digital de imagens. Os resultados foram tabulados e analisados estatisticamente por ANOVA e pelos testes de Kruskal Wallis e Mann Withney, com nível de significância de a =0,05. Observou-se que houve diferença significativa entre a infiltração na margem cervical (dentina) e infiltração total nos quatro grupos, assim como, diferença significativa entre a margem incisal (esmalte) e na margem cervical (dentina) em todos os grupos. Foi observado absorção de prata na margem cervical em todos os grupos, com maior percentagem de infiltração encontrada no Grupo 1. Não houve diferença estatística significativa entre os grupos da margem incisal (esmalte). As facetas diretas de resina composta nanoparticulada apresentaram melhor selamento em esmalte e dentina quando comparados com resina composta nanohíbrida. A resistência ao manchamento superficial parece ser semelhante em ambos as resinas compostas. Oconsumo simulado de vinho causa manchamento superficial nas facetas de resina composta.<br> / Abstract : The aim of this in vitro study was to compare the adaptation to enamel and dentin, the marginal sealing and the level of surface staining of 2 composite resins of different percent polymerization shrinkage (Charisma Diamond and Filtek Z350) in direct composite laminate veneers after being subjected to extrinsic pigmentation and thermal cycling. Thirty-two mandibular incisors, prepared to receive direct composite laminate veneers, were randomly divided into 4 groups (n = 8): Groups 1 and 3 were restored with a nanohybrid composite resin and Groups 2 and 4 were restored with a nanoparticulate composite resin. In order to evaluate the degree of surface staining, Groups 1 and 2 were stored in red wine for 14 days at 37 °C and were photographed before and after extrinsic pigmentation. The photographic records were attached to 5 evaluation scores, submitted to 2 voluntary examiners (dental surgeons). The specimens of the four groups were sectioned and immersed into silver nitrate solution after aging with 5,000 thermocycles. Nanoleakage was observed using a scanning electron microscopy (SEM), in both backscattered electron mode and EDX spectrometry dispersive mode; the percentage distribution of silver particles at the restoration/tooth interface was calculated using a digital image analysis software. The results were plotted and analyzed statistically using one-way ANOVA, and Kruskal Wallis and Mann Whitney?s tests. The level of significance was set to a =.05. Statistically significant differences were observed between dentin infiltration and total infiltration in the four groups, as well as, significant differences between enamel and dentin in all groups. It was observed clear silver uptake at the cervical margin in the four groups, with the highest microleakage percentage found in Group 1. No significant differences were observed in enamel between the four Groups. Direct composite laminate veneers of nanoparticles resin, presented better enamel and dentine adaptation when compared with direct composite laminate veneers of nanohybrid resin. The resistance to surface staining seemed to be similar in both tested groups.
24

Infiltração marginal em cavidades de classe V. Efeito de sistema adesivo e preparo cavitário

Araújo, Taylane Soffener Berlanga de [UNESP] 15 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-15Bitstream added on 2014-06-13T19:01:40Z : No. of bitstreams: 1 araujo_tsb_dr_arafo.pdf: 876638 bytes, checksum: 4edaacd253f53829f5fdb7d87cab5c0b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve por objetivo analisar in vitro a influência de dois sistemas adesivos resinosos, sendo um autocondicionante de dois passos (Clearfil SE Bond 2) e um convencional também de dois passos (Master Bond), bem como o tratamento das margens cavitárias no controle da microinfiltração marginal. Preparos cavitários de classe V foram executados na face vestibular em 80 dentes anteriores bovinos previamente extraídos, divididos em oito grupos (n=10). O grau de infiltração marginal foi avaliado por penetração do agente traçador (Nitrato de Prata (AgNO3) a 50%) nas paredes incisal e cervical por meio de um Software-Image Tool, no qual se mede o grau de infiltração em micrômetros e, portanto, análise quantitativa, os resultados submetidos à Análise de Variância seguida do teste de Tukey para observação das diferenças, concluindo-se que: a) os sistemas adesivos apresentaram estatisticamente o mesmo comportamento; b) existe diferença estatisticamente significante entre as técnicas de preparos utilizados sendo que os preparos realizados nos Grupo I e Grupo II, bem como nos Grupos VII e VIII, apresentaram comportamento semelhante e os melhores resultados para redução da microinfiltração; c) os preparos do Grupo III e Grupo IV apresentaram maiores índices de microinfiltração marginal, no entanto, semelhantes aos Grupos V e VI; d) a região cervical apresentou maior nível de microinfiltração quando comparada com a região incisal. / This study aimed to analyse in vitro the influence of two resinous adhesive systems: one self-etching of two steps (Clearfil SE Bond 2) and one also conventional of two steps (Master Bond), as well as the treatment of the cavity margins in the marginal microleakage control. Cavity preparations of class V were carried out on the buccal surface of 80 bovine anterior teeth, previously extracted, divided into eight groups (n=10). The marginal leakage degree was evaluated by the penetration of the tracer agent (Silver Nitrate (AgNO3) at 50%); on the incisor and cervical walls through a Software-Image Tool that measures the leakage degree in micrometers and, therefore, quantitative analysis, which results were subjected to the Variance Analysis and afterwards to the Tukey's test in order to observe the differences it was possible to conclude that: a) the adhesive systems presented statistically the same behaviour; b) there is a statistically meaningful difference between the preparation techniques that were used and the preparations that were carried out in Group I and Group II, as well as Groups VII and VIII, that presented similar behaviour and the best results for the reduction of microleakage; c) the preparations of Group III and Group IV presented higher rates of marginal microleakage, however, they were similar to Groups V and VI; d) the cervical region presented higher level of microleakage comparing to the incisor region.
25

Análise comparativa da infiltração marginal em restaurações de classe II em resina composta com diferentes técnicas de inserção

Macedo, Ricardo Prates [UNESP] 01 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-01Bitstream added on 2014-06-13T20:41:43Z : No. of bitstreams: 1 macedo_rp_dr_arafo.pdf: 474447 bytes, checksum: 4d9c167f257a4293018ed19aaa516902 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho, estudou-se a influência de quatro diferentes técnicas de inserção (Incremental, Única, Beta-quartzo e Pré-polimerizada) da resina composta fotoativada em dois tamanhos de cavidades classe II, no vedamento marginal, através de testes de infiltração de um agente corante. As cavidades foram preparadas em dentes molares humanos extraídos, com a parede cervical localizada em cemento. Os materiais (adesivo dentinário e resina composta) foram de uma mesma marca comercial. Realizadas as restaurações, os dentes foram submetidos à termociclagen (5o C e 55o C, durante 500 ciclo) e depois de adequadamente impermeabilizados, foram imersos em solução corante Rodamina a 5% por uma semana. Em seguida, os dentes foram cortados e avaliados, quanto à microinfiltração na interface parede gengival e material restaurador, por dois examinadores, segundo um critério pré-estabelecido (graus de 0 a 3). Após a análise dos resultados, foi possível concluir que: a técnica incremental em esmalte (Grupo 1B e 2B) foi a que apresentou os menores níveis de infiltração marginal, logo a que produziu o melhor vedamento marginal. A técnica incremental em cemento (Grupo 1C) apresentou resultados intermediários, não sendo estatisticamente diferente dos grupos 1B e 2B. A técnica com inserção de Beta Quartz Inserts (Grupos 1E e 2E), e técnica de inserção de pérolas pré-polimerizadas de resina (Grupos 1F e 2F) foram as menos efetivas em impedir a infiltração marginal. A confecção de um bisel chanfrado parece desempenhar importante papel na qualidade das margens das restaurações. / This study had the purpose of evaluating the influence of four different techniques of insertion of composite resin (Incremental, Single, Beta-quartz inserts nd Pre-cured) in two sizes of Class II cavities, regarding marginal sealing when submitted to leakage tests using a dying agent. Cavities were prepared in extracted human molars, presenting the cervical wall in the cementum area. Materials used (adhesive and composite resin) were from the same manufacturer. After the restorations were done, teeth were subjected to thermo cycling (5º C e 55º C, for 500 cycles), and then carefully coated with nail polish before submersed in a 5% Rodamine, for the period of one week. Teeth were then sectioned and evaluated to microleakage, at the interface gingival wall and restorative material, by two evaluators following pre-determined criteria (from 0 to 3). After analyzing the results it was possible to conclude that: incremental technique in enamel (Group 1B e 2B) presented the lowest levels of marginal leakage or the best marginal sealing. The incremental technique for the cementum group (Group 1C) presented intermediary results, not statistically different from group 1B e group 2B. The techniques using Beta Quartz Inserts (Groups 1E e 2E), and pre-cured pellets of resin (Groups 1F e 2F) were the least effectives in preventing the marginal leakage. The preparation of a chamfered bevel seemed to play an important role in the quality of the margins of the restorations.
26

Infiltração bacteriana nas interfaces entre implantes e pilares: efeito do desenho das conexões protéticas

Lima, Elen Guerra de [UNESP] 10 February 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:52:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-10Bitstream added on 2015-05-14T16:59:42Z : No. of bitstreams: 1 000823415.pdf: 1046424 bytes, checksum: 9f8cfb9c1c9a64a37fcfcc7f83233086 (MD5) / O objetivo do estudo foi avaliar a microinfiltração bacteriana in vitro na interface entre o pilar e o implante, comparando-se Hexágono Externo (HE), Hexágono Interno (HI), Conexão Cônica (CC), sendo esta última de 3 tipos diferentes de desenho dos componentes protéticos. Para tal, 150 conjuntos (pilar/implante) foram utilizados, divididos em cinco grupos (n = 30). G1 - pilares HE; G2 - pilares HI; G3 - pilares CC do tipo sólido; G4 - pilares CC do tipo indexado; G5 - pilares CC do tipo linha zero. Para a avaliação, suspensão das bactérias Escherichia coli (ATCC 25922) e Streptococcus sanguinis (ATCC 10557) foram inoculadas na porção apical do parafuso do pilar, sob condições estéreis. Os pilares foram fixados aos implantes e torqueados segundo recomendações do fabricante, e imersos em caldo BHI estéril durante 14 dias. Ao final do período, os conjuntos foram separados, o conteúdo interno foi sonicado, diluído, semeado e levado a estufa bacteriológica (37 ºC por 48 horas) para verificação da viabilidade e contagem das bactérias. As amostras que não continham E. coli e S. sanguinis viáveis, foram descartadas do estudo. A morfologia bacteriana foi ainda observada em microscopia eletrônica de varredura (MEV). Os resultados, em % e unidades formadoras de colônias (UFCs) foram analisados por teste estatístico ANOVA 1 fator. Não houve diferença estatística entre G2 (9,09%), G3 (21,74%), G4 (22,73%) e G5 (11,11%). Analisando-se separadamente os grupos não-turvados com E. Coli (p = 0,126) e S. Sanguinis (p = 0,962) e os grupos turvados com E. coli e S. sanguinis (p = 0,655.) com Anova 1- fator (p < 0,05), não houve diferenças significantes na contagem de UFC entre os tipos de conexões / The aim of this study was to evaluate the in vitro bacterial microleakage at the interface between the abutment and the implant, comparing 3 types of prosthetic connections: External Hexagon (EH), Internal Hexagon (IH), Taper Connection (TC), the latter of 3 different types of the design of the abutments. For this, it was utilized 150 sets (abutment / implant), that were divided into 5 groups (n = 30). G1 (Control) - EH abutments; G2 - IH abutments; G3 - TC solid abutments; G4 - TC indexed abutments; G5 - TC zero line abutments. For this evaluation, suspension of the bacterial Escherichia coli (ATCC 25922) e Streptococcus sanguinis (ATCC 10557) were inoculated in the apical portion of the abutment screw, under sterile conditions. The abutments were fixed to the implants and torqued according to manufacturer's recommendations, and immersed in sterile BHI broth for 14 days. At the end of the period all sets were separated, the inner contents was be sonicated, diluted, seeded and taken to a bacteriological incubator (37 °C for 24 hours) to check the viability of the bacteria. The samples that did not contain viable E. coli e S. sanguinis were discarded from the study. The staining and bacterial morphology were observed in optical microscope and scanning electron microscopy (SEM). Results of colony forming units (CFUs) were analyzed by ANOVA 1 factor. There were no differences between the percentage of bacterial infiltration for IH (9.09%), CS (21.74%), CI (22.73%) e C0 (11.11%). Analising separetly the groups non-infritated with E. coli (p = 0,126) and S. Sanguinis (p = 0,962) and the groups infiltrated with E. coli and S. sanguinis (p = 0,655.) (p < 0,05), there no was statistical difference in the count of CFU/ml between the connections type
27

Carbono tipo diamante em componentes de implantes dentários: avaliação das propriedades antimicrobianas e de adesão de Escherichia coli

Maquera Huacho, Patricia Milagros [UNESP] 13 March 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-13. Added 1 bitstream(s) on 2015-06-18T12:47:03Z : No. of bitstreams: 1 000830189_20170313.pdf: 149660 bytes, checksum: 52524b576bd709ce5dfcdfd29e55bc0a (MD5) Bitstreams deleted on 2017-03-17T12:38:06Z: 000830189_20170313.pdf,. Added 1 bitstream(s) on 2017-03-17T12:39:07Z : No. of bitstreams: 1 000830189.pdf: 425234 bytes, checksum: 5b7c2d176991ced4133234bd3048be4d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O estudo de filmes de Carbono tipo Diamante é objeto de pesquisas devido às suas diferentes propriedades incluindo propriedades antibacterianas. No tratamento reabilitador com implantes, podem ocorrer complicações, proporcionando a infiltração de microrganismos orais para a interface Implante-Componente protético. O objetivo deste estudo foi avaliar propriedades de molhabilidade e energia livre de superfície a partir dos valores do ângulo de contato; propriedades antimicrobiana, de bioadesão e citotoxicidade de discos de titânio recobertos com DLC. Escherichia coli foi mantida em meio BHI a 37ºC por 3 h e 24 h para teste antimicrobiano. Para adesão, os discos foram mantidos em cultura de E. coli por 90 minutos a 37ºC e 20 minutos em ultrassom. A capacidade de prevenção na migração de bactérias para o interior da interface Implante-Componente protético foi realizado em implantes Hexágono Externo, conectados com torque de 32N e deixados em contato com E. coli por 24h, e Reação em Cadeia da Polimerase semi-quantitativo foi realizado para confirmação da esterilidade da técnica. Foram quantificados em UFC/mL em BHI Ágar para o teste antimicrobiano, adesão e infiltração bacteriana. Para citotoxicidade foi utilizado queratinócitos humanos (HaCat) cultivados em meio DMEM mantidos em atmosfera com 5% de CO2 a 37°C e avaliados pelo teste colorimétrico MTT. Os resultados de molhabilidade, teste antimicrobiano, teste de adesão e Infiltração bacteriana não apresentaram diferença estatisticamente significante entre os grupos. As superfícies de titânio e recobertas com DLC apresentaram uma leve diminuição na viabilidade celular com diferença estatisticamente significante ao grupo controle. O DLC apresenta-se como material biocompatível com leve grau de citotoxicidade que não modifica as propriedades de superfície, não apresenta propriedades antimicrobianas... (Resumo completo, clicar acesso eletrônico abaixo) / The study of DLC films is the subject of research due to their different properties including antibacterial properties. Rehabilitator in implant treatment, complications may occur, providing the infiltration of oral microorganisms for implant- abutmente interface. The aim of this study was to evaluate properties and wetting surface free energy from the values of the contact angle; antimicrobial properties bioadhesion and cytotoxicity of titanium discs coated with DLC. Escherichia coli was maintained on BHI at 37 ° C for 3 h and 24 h for antimicrobial test. For adhesion test, the discs were maintained in culture of E. coli for 90 minutes at 37 ° C and 20 minutes inside ultrasound. The ability to prevent the migration of bacteria into the implant - abutment interface was performed in dental implants External Hexagon connected with a torque of 32N and left in contact with E. coli for 24 h , and Polymerase Chain Reaction semi -quantitative was performed to confirm the sterility of the technique. Were quantified in CFU / ml in BHI agar for antimicrobial test, bacterial adhesion and infiltration. Cytotoxicity was performed using human keratinocytes ( HaCaT ) cultured in DMEM maintained in an atmosphere of 5% CO2 at 37 ° C and evaluated by the MTT colorimetric assay. The results of wettability, antimicrobial test, adhesion test and bacterial infiltration showed no statistically significant difference between the test groups. The surfaces of titanium and coated with DLC showed a slight decrease in cell viability with a statistically significant difference to the control group. The DLC is presented as biocompatible material with mild cytotoxicity without changing the surface properties, has no antimicrobial properties, does not interfere with bacterial adherence for E. coli and do not inhibit bacterial infiltration into the implant-abutment interface.
28

Influência do tratamento de superfície na infiltração marginal de reparos em porcelana

Mello, Elson Braga de [UNESP] 19 June 2001 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-06-19Bitstream added on 2014-11-10T11:57:34Z : No. of bitstreams: 1 000138150.pdf: 3497636 bytes, checksum: ee38fb09ee6e0b606da5fb2a0bca6a51 (MD5)
29

Estudo da infiltração marginal em restaurações de resinas compostas para dentes posteriores: efeito de material, preparo cavitário e condicionamento do esmalte a nível cervical

Araújo, Rosehelene Marotta [UNESP] January 1989 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:30Z (GMT). No. of bitstreams: 0 Previous issue date: 1989Bitstream added on 2015-01-26T13:30:20Z : No. of bitstreams: 1 000022956.pdf: 2284097 bytes, checksum: a572b308f0f545c71d9428488580a36f (MD5) / Por muitos anos a profissão odontológica tem procurado um material estético para substituir as ligas de amálgama. Recentemente, têm aparecido no comércio as resinas compostas para dentes posteriores indicadas para restaurações onde não há incidência de forças mastigatórias. Tais resinas têm, porém, apresentado falhas, e, entre elas, a infiltração marginal, que tem enorme importância, pois é responsável pela sensibilidade pós-operatória, manchamento e ocorrência de cáries secundárias com consequentes alterações patológicas da polpa. Este trabalho teve a finalidade de estudar ''in vitro'' a infiltração marginal, a nível cervical, de restaurações classe II com as resinas posteriores quimicamente ativadas P10 e fotoativadas P30, em dois tipos de cavidades: convencional e adesiva. Foi verificado também o efeito do condicionamento ácido nesta região. A pesquisa foi realizada em dentes pré-molares recentemente extraídos por motivo ortodôntico, e para obter cavidades padronizadas os preparos foram feitos com a utilização de um microscópio modificado por GABRIELLI e cols.25 Foi utilizado adesivo dentinário (Scotchbond) em todos grupos experimentais. A infiltração foi evidenciada por meio do corante Rodamina B, após ciclagem térmica entre as temperaturas 10°C e 50°C, e analisada seguindo o critério de HIRSCH e WEINREB37, modificado, com auxílio de uma lupa estereoscópica ZEISS com 10 aumentos. Pelos resultados obtidos, pudemos verificar que: 1- Ocorreu infiltração marginal a nível cervical em 77,5% das restaurações de cavidades convencionais e em 47,5% das cavidades adesivas. 2- A maior percentagem de infiltração, independentemente dos fatores em estudo, ocorreu sempre no nível 3, ou seja, com infiltração até a parede axial. 3- Tanto a resina quimicamente ativada quanto a fotoativada permitiram a mesma infiltração. 4- O condicionamento ... / For many years the dental profession has sought an esthetic material to replace the amalgam alloys. Recently composite resins for posterior teeth have been introduced into the marketplace. The manufacturers claimed that these materials are indicated for stress-bearing restoration. However. such resins have presented some limitations such as marginal leakage which has great clinical importance because it is responsible for postoperative sensitivity, and occurence of secundary caries followed by pathological changes of the pulp. The purpose of this ''in vitro'' study was to investigate the cervical marginal leakage in class II restorations with chemically cured resin - PlO - and light- cured resin - P30 - in two types of cavities: conventional and adhesive. The effect of acid-etching in this area was also observed. The cavities were prepared in premolar teeth, recently extracted for orthodontic purposes, using a Microscope Modified by GABRIELLI and cols.25, in order to obtain standardized cavities. Dentine adhesive (Scotchbond) was used in all experimental groups Leakage was evidenced by Rodamina B dye penetration after thermocycling procedure between 10°C and 50ºC temperature and analysed according to HIRSCH g WEINREB modified criterion by using ZEISS Stereoscopic Magnifying Glass (10x). According to the results, we should concluded that: 1- Cervical marginal leakage occurred to 77,5% of conventional cavities restorations and 47,5% of adhesives cavities. 2- The major percents of leakage, regardless the factors studied, always occurred at level 3, that is, with leakage up to axial wall. 3- Either chemically cured resin or light – cured resin presented the same leakage. 4- The acid-etching reduced from 70% to 55% the leakage percentage observed. 5- The leakage observed for adhesive or conventional cavities continued when chemically cured resin or light- cured resin was used. 6- Acid-etching...
30

Análise morfológica de cones de guta-percha submetidos a diferentes tratamentos de desinfecção e sua influência na microinfiltração

Rosa, Patrícia Campos Ferreira da [UNESP] 09 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-09Bitstream added on 2014-06-13T19:11:07Z : No. of bitstreams: 1 rosa_pcf_me_sjc.pdf: 2680312 bytes, checksum: d4fad1db60829c4daa185168c5bf357e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os cones de guta-percha precisam passar por um processo de desinfecção química rápida antes da obturação. Algumas soluções são capazes de agir em 1 minuto, mas se este período de imersão for prolongado, alterações podem ser causadas na estandardização dos cones, dificultando a adaptação ao canal radicular. Essa pesquisa avaliou as alterações morfológicas, em microscopia eletrônica de varredura (MEV), que ocorrem na superfície dos cones de guta-percha em períodos excedidos aos preconizados. Clorexidina 2% (CLX), hipoclorito de sódio 2,5% (NaOCL), ácido peracético 2% (AP) e solução de ácido peracético 0,25% (SAP) foram as soluções utilizadas nos períodos de 1 minuto, 30 minutos, 6 horas e 12 horas. Os grupos foram divididos de acordo com a solução e período de desinfecção (n=12). Os resultados indicaram que houve diferença estatística significante entre as soluções e períodos testados. Em 1 minuto, todas as soluções não diferiram do controle. Após 30 minutos, a SAP alterou significativamente a morfologia dos cones. O teste de espectrometria de energia dispersiva (EDS) indicou que todas as substâncias e períodos alteram a composição química dos cones de gutapercha. A relação da desinfecção na microinfiltração da obturação também foi avaliada nos grupos que sofreram desinfecção por 12 horas. O grupo da SAP apresentou diferença estatística significante em relação ao controle, pois 100% das suas raízes apresentaram infiltração. Os demais grupos da CLX, NaOCL e AP, embora sem diferença estatística significante, tiveram respectivamente 9, 8 e 8 do total de 12 das suas raízes com infiltração. Conclui-se que o processo de desinfecção pode causar alterações morfológicas se o período de imersão for excedido e que, além de alterarem a composição química dos cones de guta-percha, estas soluções podem influenciar no selamento da obturação / The gutta-percha points must go through a fast chemical disinfection process before obturation. Some solutions are able to work in 1 minute, but if this immersion period is prolonged, changes can be caused on the points standardization, hampering the adaptation to root canal. This study evaluated the morphological changes, in scanning electron microscopy (SEM), which occur on the surface of gutta-percha points in periods beyond the recommended. 2% chlorhexidine (CLX), 2.5% sodium hypochlorite (NaOCl), 2% peracetic acid (PA) and peracetic acid solution 0.25% (PAS) were used for 1 minute, 30 minutes, 6 hours and 12 hours. The groups were divided according to disinfecting solution and period (n = 12). The results indicated a statistically significant difference between the solutions and periods tested. In one minute, none of the solutions differed from control. After 30 minutes, PAS has significantly changed the morphology of the points. The energy dispersive x-ray test (EDS) showed that all substances and periods, alter the chemical composition of the gutta-percha points. The ratio of the disinfection on microleakage of the filling was also evaluated. The SAP 12 hours group had a statistically significant difference compared to the control and the other groups, since 100% of their roots showed infiltration. Groups of 12 hours period of CHX, NaOCl and PA, although without significant difference, had respectively 9, 8 and 8 out of 12 of its roots with infiltration. It is concluded that the disinfection process can cause morphological changes if the immersion period is exceeded and that, besides altering the chemical composition of gutta-percha points, these solutions can influence on the hermetic sealing of the root canal

Page generated in 0.1234 seconds