• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 417
  • 7
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 428
  • 258
  • 235
  • 129
  • 125
  • 98
  • 84
  • 83
  • 80
  • 78
  • 64
  • 51
  • 49
  • 45
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Desenvolvimento de estratégias analíticas para determinação do anti-hipertensivo furosemida / Development of analytical strategies for the determination of the anti-hypertensive furosemide

Felipe Silva Semaan 19 October 2007 (has links)
O presente trabalho teve por objetivo o desenvolvimento e aplicação de diferentes procedimentos para quantificação do fármaco furosemida, explorando suas reações e características físicas. Os métodos apresentados podem ser divididos em estáticos e em fluxo. Dentre os procedimentos estáticos utilizou-se a titrimetria de óxido-redução, a qual explorou as reações de hidrólise e oxidação do fármaco; a determinação espectrofotométrica em batelada, que explorou a reação de complexação com íons Fe3+, e a determinação empregando métodos eletroanalíticos, como voltametria cíclica, de pulso diferencial e de onda quadrada, nos quais o comportamento eletroquímico do analito foi explorado. Todos os procedimentos estáticos serviram de base para o desenvolvimento de procedimentos dinâmicos, em fluxo, visando minimizar a manipulação de padrões e amostras, bem como reduzir o consumo de reagentes e soluções, a geração de resíduos e aumentar a freqüência analítica. Com relação aos procedimentos dinâmicos foram realizados experimentos empregando detectores espectrofotométricos com base em reações de óxido-redução e complexação, fluorimétricos, com base na emissão pelo analito quando excitado e no seu aumento em ambientes micelares, e eletroanalíticos, com base na hidrólise e oxidação do fármaco em meios adequados. Observou-se, como previsto, perda de sensibilidade nos métodos dinâmicos quando comparados aos procedimentos estáticos, porém com aumento na freqüência analítica, redução de custos operacionais, minimização na manipulação das soluções. Os resíduos gerados foram reaproveitados na maioria dos casos. Todos os procedimentos descritos foram aplicados a amostras comerciais e/ou material biológico sintético, com resultados satisfatórios quando comparados estatisticamente aos obtidos para mesma amostra por meio de método de comparação oficial. Ensaios de adição e recuperação demonstraram, também, a aplicabilidade das estratégias apresentadas; não foram observadas interferências dos demais constituintes das formulações farmacêuticas. / The development and application of different procedures for the quantification of the drug furosemide, exploiting its reactions and physical properties are described. The presented methods were based in static and flow injection procedures. Among the static redox procedures titrimetry was applied, which exploited the hydrolysis and oxidation reactions of this drug; batch spectrophotometric determination was carried out applying the complexation between furosemide and ferric ions and, electroanalytical determinations, by cyclic, differential pulse and square wave voltammetry, were developed exploiting the electrochemical behavior of the analyte. All the static procedures were used as base to the development of flow injection methods, aiming to minimize the manipulation of standards and samples, as well as to reduce the reagent and solutions consumes and the waste generation, and to improve the analytical frequency. Based on the flow injection procedures some experiments were developed using spectrophotometric detectors, applying redox and complexation reactions; fluorimetric detectors, based on the fluorescence emission generated by the analyte when excited and exploiting its improvement by micellar media; and electrochemical detectors, based on the hydrolysis and oxidation under suitable conditions. Lost of sensitivity could be observed in the flow injection procedures, on the other hand, improvement on analytical frequency, reduction on operational costs and minimization on solutions handling could also be noted. The waste generated was reused in the majority of the cases. All the procedures described were applied to commercial samples and/or synthetic biological material, with satisfactory results when statistically compared to those obtained by a reference method to the same samples. Recovery tests also demonstrated the applicability of the developed strategies. Interference from the constituents of the pharmaceutical formulations was not observed.
162

Produção e fornecimento de vapor de etanol para motor de combustão interna operando com combustível pré-vaporizado / Ethanol vapor production and feeding for an internal combustion engine operating with pre-vaporized fuel

Francisco José Alves 23 November 2007 (has links)
O motor a álcool pré-vaporizado tem potencial para ser uma alternativa mais eficiente e menos poluente aos motores a álcool convencionais. Nele, o combustível é vaporizado com calor rejeitado pelo próprio motor e admitido na fase gasosa, aproveitando-se das vantagens dos motores com combustíveis nessa fase sem alguns dos seus inconvenientes. O projeto foi aperfeiçoado buscando viabilidade técnica e econômica para sua instalação em veículos automotores. Água do sistema de arrefecimento cede calor para a ebulição do combustível. As novas tecnologias para injeção de combustíveis gasosos contribuem para esse objetivo, bem como o desenvolvimento de um sistema sustentável e auto-ajustável de geração de vapor de etanol que usa a água do sistema de arrefecimento. Conseguiu-se maior eficiência em quase todos os regimes de funcionamento estudados, bem como meios de reduzir as principais emissões automotivas indesejáveis. / Pre-vaporized ethanol engine (PVEE) has potential to be more efficient and less pollutant than conventional ethanol-powered engines. In it, fuel is vaporized with heat rejected by engine itself and intook in gaseous form, taking advantage of this kind of fuel but without some of its inconveniences. The PVEE project was polished looking for economical and technical liability to future use in automotive vehicles. New gaseous fuel injection technologies contribute to this goal, together the development of a sustainable and self-adjustable ethanol vapor generating system who uses water from engine\'s cooling systems. Better efficiency was achieved in almost all investigated regimes, as well as were found ways to reduce the main undesirable automotive emissions.
163

Desempenho de um motor ciclo Otto com injeção direta de gás natural / Performance of a motor Otto cycle with direct natural gas injection

Cleiton Rubens Formiga Barbosa 04 April 1997 (has links)
Um motor ciclo Otto funcionando com injeção direta de gás natural, durante o curso de admissão, foi submetido a ensaios de plena carga em um dinamômetro corrente de Foucaut. Os resultados obtidos revelam um aumento de eficiência volumétrica do motor com injeção direta de GNC em relação à injeção indireta de GNC realizada no coletor de admissão, a montante da borboleta do acelerador. Na adaptação para operação com injeção direta de gás natural, as características técnicas do motor não foram alteradas. Um conjunto de injeção direta de gás natural, com gerenciamento eletrônico, foi inserido no cabeçote do motor de testes. Mantendo-se a pressão da linha de alimentação de gás natural constante, através de uma válvula redutora, a quantidade de combustível injetada no cilindro foi ajustada variando-se o tempo de abertura da válvula elétrica injetora de combustível. Dados de desempenho do motor são comparados, destacando-se os fatores que contribuem para este aumento relativo de eficiência volumétrica. Discute-se ainda, modificações a serem implementadas no motor visando maximizar sua potência com injeção direta de gás natural / Otto cycle engine direct injection natural gas, during the inlet stroke, submitted to runs with full power in a Foucaut dynamometer. The results obtained show a increase in the volumetric efficiency of the engine with natural gas direct injection when compared which natural gas injection apllied in the inlet manifold, upstream of the throttle butterfly. ln the conversion to natural gas direct injection, the technical characteristics of the were not changed. A kit for natural gas direct injection, with eletronic managment, was located on the cylinder head of the test engine. Maintaining the pressure constant in the natural gas fuel line, using a reduction valve. The mass of fuel injected into the cylinder was regulated, varying the opening time of the solenoid valve fuel injector. Engine performance data is compared, emphasizing the factors that contribute to this increase in relative volumetric efficiency. Modifications to be made to maximize the power of the engine with natural gas direct injection
164

Metalotioneínas em Tilápias (Oreochromis niloticus), (Linnaeus, 1758): dinâmica de formação e desintoxicação avaliada através de bioensaios com o emprego de marcadores isotópicos de 111Cd e 65Cu / Metallothionein in tilapia Oreochromis niloticus (Linnaeus 1758): dynamic of formation and detoxification evaluated by bioassays with the use of isotopic tracers 111Cd and 65Cu

Tatiana Cristina Senra Motta 22 January 2013 (has links)
Este trabalho apresenta a pesquisa de interação de organismos aquáticos com metais, especificamente cobre e cádmio assim como da combinação deles. Para tanto, descreve-se um protocolo baseado em ensaios de toxicidade com tilápias Oreochromis niloticus, desenvolvido com a finalidade de estabelecer a concentração letal 50 (CL50) 96h. Como recurso adicional, focando a translocação de metais, foram utilizadas soluções enriquecidas isotopicamente de 65Cu (99,7%) e 111Cd (95,5%), as quais foram aplicadas através de injeções intraperitoneais. As concentrações dos metais nos tecidos e nas frações citosólicas do fígado, brânquias e músculo foram determinadas a partir dos extratos preparados em solução tampão tris-HCl 50 mmolL-1, agentes redutores e antiproteolíticos, na proporção 3:1 (m/v). Adicionalmente, foram determinados os teores de proteínas totais seguidos da etapa de isolamento das metalotioneínas. As concentrações letais (CL50) 96h calculadas pelo método Trimmed Spearman-Karber (95% de confiança), foram iguais a 20,13, 3,53 e 1,36 mg L-1 para cádmio, cobre e cobre+cádmio respectivamente. Estes valores indicam uma significativa diferença na sensibilidade dos organismos aos diferentes tratamentos. Observou-se uma redução na bioconcentração dos metais em função da concentração do metal e do tecido analisado, esta é maior para o Cu do que para o Cd e menor para o musculo em relação a brânquia e ao fígado. Os teores de proteínas totais nos tecidos foram determinados e os valores encontrados estiveram entre 3,25 mg/mL para fígados e 11,83 mg/mL para músculo. A presença de MTs nos diferentes tecidos e respectivos tratamentos, foi pesquisada empregando-se eletroforese capilar e separação de proteínas utilizando a eletroforese em gel de poliacrilamida. Por ambas as técnicas eletroforéticas foi possível identificar as metalotioneínas. Contudo, as análises dos extratos dos tecidos por espectrometria de massas, MALDI-TOF/TOF (matrix-assisted laser desorption/ionization) e ESI-MS (electrospray tandem mass spectrometry ) não mostraram-se adequadas para identificação de metalotioneínas / This paper discuss the interactions of Cd, Cu and it mixture upon aquatic organisms. To reach for these goals lethal 50 (LC50) acute toxicity 96h assays were carried out. In order to assess for the metals translocation in fish, isotopically enriched solutions of 65Cu (99,7%) and 111Cd (95,5%), were used, through an intra-peritoneal injections. Metals concentrations in tissue and in the citossolic fractions of liver, and muscular tissue were analysed in the 50 mmol-1 tris-HCl buffer solutions, reducing and un-proteolitic (3:1) solutions. In addition the total protein content were determinate, followed by the metalothyonein isolation. Lethal concentrations were calculated by the Spearman-Karber method at 95% confidence interval, as 20.13, 3.53 and 1.36 mgL-1 for Cd, Cu and Cd+Cu respectively, which denote differences in organisms sensitivity according to the treatment. Metal bio-concentration was reduced depending on the analyte concentration and kind of tissue, being higher to Cu than to Cd. Total protein concentration varied from 3.35 mg L-1 for liver to 11.83 mg L-1 in the muscular tissue. The occurrence of MTs in tissues and in all treatments were investigated by using both, capillary electrophoresis and gel of polyacrilamide. In all situations the occurrence and identification of Mts were verified, but even with MALDI-TOF/TOF (matrix-assisted laser desorption/ionization) and ESI-MS (electronspray tandem mass spectrometry), or actual instrumental facilities no satisfactory results were obtained, being not possible the identification of MTs in the analysed samples
165

Desenvolvimento de uma nova versão do injetor comutador automático: determinação fotométrica de etanol em bebidas destiladas / Development of a new version of the automatic injector commutator: photometric determination of ethanol in spirits

Felisberto Gonçalves Santos Junior 12 September 2012 (has links)
Neste trabalho, apresentamos uma nova versão do injetor comutador, baseada na geometria retangular, mantendo a configuração de três peças, sendo a central móvel e as laterais fixas. Nesta condição, os parafusos de ajuste não funcionam como guia, tal como ocorre nos injetores da primeira geração. Este design facilita o deslocamento da parte móvel, contribuindo para a redução do atrito, o que permite o emprego de um pequeno motor de corrente contínua (12 V; 0,4 A), o qual foi usado para fazer o deslocamento da barra central da posição de amostragem para a de injeção e vice-versa. O funcionamento do injetor foi controlado pelo computador, usando apenas 2 bits de controle. A interface de controle projetada para esse fim, inclui a condição de reversão da direção de rotação do motor e lógica anti-duplicidade, então se os dois bits forem ativados ao mesmo tempo, a rotação do motor é mantida no sentido horário. Para testar a viabilidade deste injetor, o mesmo foi empregado para desenvolver um procedimento para determinação de etanol em bebidas destiladas. O procedimento fotométrico foi baseado na reação de etanol com dicromato de potássio. A detecção fotométrica foi realizada empregando um fotômetro de LED com máximo de emissão em 590 nm. O módulo de análise constituído pelo injetor e um conjunto de válvulas solenoide foi projetado para implementar o processo de reamostragem, adição intermitente de reagentes e transporte da zona de amostra com fluxo de ar. Após a definição das variáveis de controle, o sistema apresentou bom desempenho analítico, aliando vantagens tais como, boa velocidade, simplicidade de operação, versatilidade, proporcionando também um menor consumo de amostra e reagentes. Com relação às características analíticas, o sistema proposto apresentou faixa de resposta linear (r = 0,9972) para concentração etanol entre 10 - 50 % (v/v), limite de detecção de 2,0 % (v/v) etanol, desvio padrão relativo de 2,0 % (n =10) para uma amostra de etanol com concentração 40 % (v/v), um consumo de dicromato de 0,012 g por determinação e uma frequência analítica de 34 determinações por hora. / We present a new version of the commutator injector, based on the rectangular geometry, maintaining the three parts configuration with the central mobile and fixed side. In this condition, the adjusting screws do not functi as a guide, as occurs in the injector of first generation. This design facilitates the displacement of the movable part and contributes in reducing the friction, thus allowing the use of a small direct current motor (12 V, 0.4 A), which was used to perform the displacement of the central bar from the sampling position to the injection and vice-versa. The injector operation was controlled by a computer, which was done using only two control bits. The control interface designed for this purpose includes the condition for reversing the direction of the motor rotation and anti-duplication logic, so that both bits were activated at the same time, the motor rotation was maintained at clockwise direction. To test the feasibility of the injector, it was used to develop a procedure for determination of ethanol in spirit beverage. The procedure was based on the photometric reaction of ethanol with potassium dichromate. The photometric detection was performed using a LED based photometer with maximum of emission at 590 nm. The analytical module comprising the injector and a set of solenoid valves, was designed to implement the zone sampling process and Intermittent addition of reagents and sample zone displacement using an air stream. After definition of control variables, the system shown good analytical performance, combining advantages such as speed, simplicity of operation, versatility and also providing lower consumption of sample and reagents. With respect to analytical characteristics, the proposed system presented linear response range (r = 0.9972) between ethanol concentration to 10 - 50% (v/v), a detection limit of 2.0% (v/v) ethanol, relative standard deviation of 2.0% (n = 10) for a sample with an ethanol concentration of 40% (w/v), a dichromate consumption of 0.012 g by determination and a sampling rate of 34 determination per hour.
166

Desenvolvimento de molde de material cerâmico para aplicação em moldagem por injeção de materiais poliméricos

Heiderich, Danilo Carvalho 15 October 2014 (has links)
Made available in DSpace on 2016-03-15T19:36:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-15 / Universidade Presbiteriana Mackenzie / The need for speed increasing production, reducing weight and price of the product and the need for creation of complex parts made the use of polymeric materials, increasingly feasible in relation to other materials. The implementation of polymeric materials in various areas of production ensure the continued development of techniques for forming the same, with advances in technology also creates the need to increase the speed of transition between the development stages of a project as well as reducing the costs involved to achieve project deadlines and keep it commercially competitive. In view of the mechanical properties of ceramic material and its ease of forming was objective the creation of a plastic injection mold made of ceramic material. For this we performed a brief study of the main means of forming polymer and a study on the properties of ceramic and polymeric materials. Was later developed the part to be injected, and from the same, the ceramic mold that is used. After scaling the same calculations were made to adapt the project to verify its viability and the process of analysis by finite elements. These results show that the injection pressure and the necessary clamping force are below the maximum forces, supported by ceramic material, which demonstrates the viability of the ceramic mold, as an alternative to traditional metal molds. / A necessidade de velocidades de produção cada vez maiores, redução de pesos e preço do produto e a necessidade da criação de peças complexas tornaram o uso de materiais poliméricos, cada vez mais viável em relação aos demais materiais. A implementação dos materiais poliméricos nas mais diversas áreas de produção implica no desenvolvimento contínuo das técnicas de conformação dos mesmos, porém com os avanços tecnológicos cria-se também a necessidade de aumentar a velocidade de transição entre as etapas de desenvolvimento de um projeto bem como a redução dos custos envolvidos no processo a fim de atingir os prazos do projeto e mantê-lo comercialmente competitivo. Tendo em vista as propriedades mecânicas do material cerâmico bem como sua facilidade de conformação objetivou-se a criação de um molde para injeção de plásticos feito de material cerâmico. Para isso foi realizado um breve estudo sobre os principais meio de conformação de polímeros também um estudo sobre as propriedades dos materiais cerâmicos e poliméricos. Posteriormente foi desenvolvida a peça a ser injetada e, a partir da mesma, o molde cerâmico que será utilizado. Após o dimensionamento do mesmo foram realizados os cálculos de adequação do projeto para verificar a sua viabilidade bem como a análise pelo processo de elementos finitos. Os resultados deste estudo mostram que as pressões de injeção bem como a força de fechamento necessária são inferiores às forças máximas, suportadas pelo material cerâmico, o que demonstra a viabilidade da criação do molde cerâmico, como alternativa aos moldes metálicos tradicionais.
167

Análise de diferentes metodologias executivas de solo pregado a partir de arrancamento realizados em campo e laboratório / Analysis of different soil nailing executive methods from pullout tests performed in field and laboratory

Danilo Pacheco e Silva 07 August 2009 (has links)
Apesar do largo emprego da técnica de solo pregado em nosso país, pouquíssima pesquisa foi realizada sobre a resistência ao cisalhamento de interface solo-reforço (qs) e sobre a importância deste parâmetro no desempenho desta técnica de reforço in situ de taludes e escavações. Busca-se com esta tese, avaliar experimentalmente, a influência de diferentes metodologias executivas do chumbador (número de injeções) neste parâmetro. As informações para o desenvolvimento deste trabalho foram obtidas a partir de ensaios de arrancamento realizados em chumbadores construídos em duas obras nas cercanias da cidade de São Paulo, ou seja, em escala real. De forma complementar, também foi construído uma estrutura de solo pregado em laboratório. A partir dos ensaios realizados, observaram-se melhorias significativas na resistência ao cisalhamento de interface a partir das injeções do chumbador e estabelecer equações que relacionam o valor de qs com o volume injetado de calda de cimento, sendo uma importante ferramenta para analisar o desempenho do chumbador. O monitoramento ao longo do ensaio permitiu analisar os mecanismos de distribuição das cargas. Por fim, é apresentada uma proposta de metodologia para a realização do controle de qualidade do chumbador. / Besides the soil nailing technique being common practice in Brazil, there is little research on the shear strength of the soil-reinforcement interface (qs) and on the importance of this parameter on the performance of this in situ reinforcement technique of slopes and excavations. Accordingly, this study has the objective to experimentally evaluate the influence of different executive methodologies of the nail (i.e. number of grout injections) on the parameter qs. Data were obtained from in situ, full scale pullout tests performed on nails built in two construction sites near Sao Paulo city. Additionally, a soil nailing structure was built in laboratory. The results show that significant improvement is achieved on the soil-nail interface shear strenght by the number of grout injections. Moreover, the pullout tests on the nails provided quantification of this improvement. Consequently, it was possible to establish equations that relate the value of qs to the volume of cement grout injected, which is as important tool to evaluate the performance of the nail. Monitoring of the instrumentation during execution of the pullout tests allowed evaluation of the mechanisms of load distribution along the nails. Finally, a methodology is proposed for a quality control procedure on soil-nailed walls.
168

Metodologia intervalar para tratamento de incertezas em problemas de fluxo de potência / Interval method for handling uncertainties in power flow problems

Pereira, Luiz Eduardo de Souza 05 April 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-24T12:34:54Z No. of bitstreams: 1 luizeduardodesouzapereira.pdf: 2003245 bytes, checksum: 5a64db7cc6de6ef524f087c6d4cdb47e (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-24T16:55:28Z (GMT) No. of bitstreams: 1 luizeduardodesouzapereira.pdf: 2003245 bytes, checksum: 5a64db7cc6de6ef524f087c6d4cdb47e (MD5) / Made available in DSpace on 2017-04-24T16:55:28Z (GMT). No. of bitstreams: 1 luizeduardodesouzapereira.pdf: 2003245 bytes, checksum: 5a64db7cc6de6ef524f087c6d4cdb47e (MD5) Previous issue date: 2011-04-05 / A análise do fluxo de potência determinístico é restrita a um único instante de tempo específico. Contudo, as demandas de potência ativa e reativa, dentre outros, variam constantemente e afetam o perfil das tensões nodais e as distribuições dos fluxos de potência nos ramos do sistema elétrico. Desta forma, a utilização do modelo determinístico seria inviável face às inúmeras simulações necessárias no sentido de representar todas as possíveis combinações das variações envolvidas no problema. Por outro lado, com a utilização da matemática intervalar é possível representar intervalos de variação da demanda ativa e reativa e obter, através de um fluxo de potência intervalar, o perfil das tensões nodais, as distribuições de fluxo de potência nos ramos e as perdas também na forma intervalar. Por conseguinte, é possível realizar uma análise detalhada e completa do comportamento da rede frente às variações em estudo. Da mesma forma que no fluxo de potência determinístico, a metodologia intervalar apresenta diferentes desempenhos dependendo da forma como as equações básicas que definem o problema do fluxo de potência são expressas. Portanto, a proposta do trabalho é inicialmente modelar e implementar as metodologias de fluxo de potência intervalar nas versões polar, retangular e injeção de correntes. Posteriormente, o trabalho apresenta um estudo comparativo entre as várias versões aplicada ao problema das incertezas no fluxo de potência em redes de energia elétrica. / The analysis of the deterministic power flow is restricted to a single time instant. However, the active and reactive load powers, among others, vary constantly and affect the voltage profiles and line flows throughout electric power systems. Therefore, the deterministic model is not feasible due to a number of simulations required to represent all possible combinations of the variations involved in the problem. On the other hand, it is possible to represent the variations of active and reactive load powers by interval mathematics. As a result, voltage profiles, line flows and losses can be calculated, in an interval manner, by using an interval power flow. Therefore, a detailed and comprehensive analysis of the system behavior can be efficiently performed. Both the interval and deterministic power flow methods have different performance depending on how the basic power flow equations are expressed. Therefore, the purpose is to firstly model and implement load flow methodologies in polar, rectangular and current injections versions. Next, this dissertation presents a comparative study between the versions applied to power flow problem with uncertainties.
169

Nanolasers de semicondutor metálico-dielétrico com bombeio eletrônico = a influência do meio de ganho / Metallo-dielectric semiconductor nanolasers with electronic pumping : the influence of the gain media

Vallini, Felipe, 1985- 23 August 2018 (has links)
Orientador: Newton Cesario Frateschi / Tese (doutorado) - Universidade Estaual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-23T21:02:10Z (GMT). No. of bitstreams: 1 Vallini_Felipe_D.pdf: 6501837 bytes, checksum: 9c23f9afa5633adc0e7fa246e3bcafc5 (MD5) Previous issue date: 2013 / Resumo: Neste trabalho são investigados os nanolasers de semicondutor do tipo metálico-dielétrico com injeção eletrônica. Com o uso de softwares robustos otimizamos as propriedades eletromagnéticas das cavidades propostas através da solução das equações de Maxwell em um meio material. Também resolvemos auto-consistentemente as equações de Poisson, de continuidade, de transporte e de Schroedinger para obter as propriedades eletrônicas da cavidade. Tal otimização, considerando a parte de confinamento do modo em conjunto com a parte da injeção eletrônica nunca havia sido proposta ou realizada para nanolasers. Estudamos o efeito do meio de ganho em um nanolaser desse tipo através da comparação do desempenho de um nanolaser com meio de ganho bulk e outro com meio de ganho de múltiplos poços quânticos. Essa análise foi feita inserindo um modelo de reservatório de portadores às equações de taxa convencionais para nanolasers. Fabricamos dois nanolasers, um com cada meio de ganho. Os nanolasers foram caracterizados e demonstramos que um meio de ganho bulk é mais adequado ao desenvolvimento de nanolasers de semicondutor metálico-dielétrico com bombeio eletrônico. Por fim, medimos um nanolaser com meio de ganho bulk a 77 K, o qual apresentou uma corrente de limiar da ordem de 2 mA, emissão em 1567 nm e largura de linha de 0.4 nm / Abstract: In this work we have investigated metallo-dielectric semiconductor nanolasers with electronic pumping. We have optimized the electromagnetic properties of the proposed cavities through the solution of Maxwell equations in a material media using robust software. We also solved self-consistently Poisson, continuity, transport and Schrodinger equations to obtain the electronic properties of the cavities. Such optimization, which considers the optical mode confinement together with the electronic injection, had not been proposed or realized for nanolasers yet. We have studied the effect of the gain media in this class of nanolaser comparing the performance of a nanolaser with bulk gain media and a nanolaser with multiple quantum wells gain media. This analysis was done inserting a reservoir model for carriers into conventional laser rate equations. We have fabricated two nanolasers, each one with one of the proposed gain media. The nanolasers were measured and we demonstrated that a bulk gain media is more suitable for the development of metallo-dielectric semiconductor nanolasers with electronic pumping. Finally, we have measured a bulk gain media nanolaser at 77 K, with a threshold current of 2 mA, emission at 1567 nm and a linewidth of 0.4 nm / Doutorado / Física / Doutor em Ciências
170

Cinematica e Dinamica de uma maquina injetora de plasticos

Rocha Junior, Jose Carlos Freire da 30 March 1999 (has links)
Orientador: Ilmar Ferreia Santos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-24T22:41:35Z (GMT). No. of bitstreams: 1 RochaJunior_JoseCarlosFreireda_M.pdf: 5587641 bytes, checksum: e309787b70fbd2736854054838461ab1 (MD5) Previous issue date: 1999 / Resumo: Este trabalho tem como objetivo simular o funcionamento do mecanismo de fechamento de uma máquina injetora de plásticos de 5 pontos, com a finalidade de gerar dados para projetá-Ia de maneira mais eficiente. Foi desenvolvido um programa computacional, para a análise cinemática e dinâmica do mecanismo, considerando-se os vínculos, a geometria do mecanismo, o atrito entre componentes, as propriedades geométricas como massa, inércia e centro de gravidade, e em seguida aplicando-se o método de Newton-Euler. Com os resultados gerados, é possível determinar a força de travamento disponível para a máquina e a curva da força de fechamento, viabilizando o dimensionamento, de maneira mais precisa e econômica, do sistema hidráulico da máquina, que fornece a vazão de óleo necessária para realizar o movimento. Os resultados desse trabalho são de fundamental importância para o projeto otimizado deste tipo especial de máquina, assim como para pesquisas futuras na área de análise estrutural ou projeto do sistema de controle, onde é necessário o conhecimento do comportamento dinâmico da máquina e de seus componentes / Abstract: The simulation of an injection molding machine clamp mechanism is presented in this work aiming data generation to design in a wiser way. A computational program was written, for mechanism kinematic and dynamic analysis, considering the constraints, the mechanism geometry, friction between components, geometric properties (mass, inertia and gravity center) and applying the Newton-Euler method. With the aftermath, it is possible to determine the clamp force available and the closing force curve, making possible to project in a precise and economical way, the hydraulic system, which supplies the oil outlet needed to execute the motion. The results are of fundamental importance in the optimization of such machines, for future studies where it is necessary to know the dynamic behavior of the machine and its components, in structural analysis or control system design / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica

Page generated in 0.0604 seconds