• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 417
  • 7
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 428
  • 258
  • 235
  • 129
  • 125
  • 98
  • 84
  • 83
  • 80
  • 78
  • 64
  • 51
  • 49
  • 45
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

"Desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação espectrofotométrica de tensoativos em águas" / "Development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters"

Lavorante, André Fernando 23 February 2006 (has links)
"Neste trabalho, propõe-se o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de tensoativos em águas empregando o conceito de multicomutação em fluxo. Visando a miniaturização do sistema, a minimização do consumo de reagentes, e da geração de efluentes foram utilizadas mini-bombas solenóide para a propulsão dos fluidos e válvulas solenóide de estrangulamento para controlar a manipulação das soluções. Estes dispositivos foram controlados por um microcomputador equipado com uma interface eletrônica baseada no circuito integrado ULN2803A a qual foi acoplada à saída da impressora. Como sistema de detecção foram empregados um espectrofotômetro HP8452A, um espectrofotômetro multicanal com arranjo linear de fotodetectores do tipo CCD e um fotômetro baseado em dois LEDs (azul e vermelho) como fonte de radiação e um fotodiodo de silício (IPL10530DAL) como detector. A aquisição dos dados do fotômetro foi realizada com um multímetro digital com saída serial RS232, empregando um programa escrito em linguagem VISUAL BASIC 3.0. No mesmo programa foram incluídas rotinas para controle do módulo de análise. Primeiramente, foram desenvolvidos a instrumentação e os procedimentos analíticos para a determinação independente de tensoativos aniônicos e catiônicos em águas. O mesmo módulo de análises foi utilizado para os dois tensoativos e foi constituído de quatro mini-bombas solenóide. O procedimento proposto para a determinação de tensoativos aniônicos foi baseado na substituição do reagente cromogênico alaranjado de metila (MO) pelo tensoativo aniônico dodecilbenzeno sulfonato de sódio (DBS), formando o par-iônico com o tensoativo catiônico cloreto de cetilpiridino (CPC) em pH 5,0. A instrumentação proposta possibilitou a obtenção de resposta linear entre 1,4 x 10-6 mol L-1 e 1,4 x 10-5 mol L-1 (0,5 - 5 mg L-1) (R = 0,997, n = 7), limite de detecção de 9,8 x 10-8 mol L-1 (0,034 mg L-1), e freqüência de amostragem de 60 determinações por hora. O desvio padrão relativo foi estimado em 0,8 % (n = 11) usando uma solução de referência contendo 5,7 x 10-6 mol L-1 (2 mg L-1) de DBS. Os resultados obtidos pelo método proposto processando amostras de efluentes domésticos e industriais foram comparados com os obtidos empregando-se o método de referência, e não foi observada diferença significativa em nível de confiança de 95 %. Para a determinação de tensoativos catiônicos em águas foi desenvolvido um procedimento baseado na formação do complexo ternário entre tensoativo catiônico CPC, Fe (III) e cromazurol S (CAS) em pH 4,5. Com o sistema proposto, utilizando-se uma cela de detecção de 40 mm de comprimento, obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,999, n = 9), limite de detecção estimado em 1,0 x 10-7 mol L-1 (0,035 mg L-1), desvio padrão relativo de 0,6 % (n = 11) empregando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC, e freqüência de amostragem de 72 determinações por hora. O procedimento foi aplicado em amostras de águas coletadas no rio Piracicaba. Empregando-se teste de adição e recuperação foi observada recuperação entre 91 % e 106 %. O módulo de análise para a determinação seqüencial de tensoativos aniônicos e catiônicos foi constituído de duas mini-bombas solenóide e seis válvulas solenóide de estrangulamento. Com o sistema proposto, as características analíticas para os tensoativos aniônicos foram: resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,35 - 10,5 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,6 x 10-7 mol L-1 (0,056 mg L-1); desvio padrão relativo de 0,6 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,5 mg L-1) de DBS. Para os tensoativos catiônicos obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10?5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,4 x 10-7 mol L-1 (0,05 mg L-1); desvio padrão relativo de 0,5 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC. O consumo das soluções de reagentes e de amostra foram de 400 mL e 200 mL, respectivamente, e freqüência de amostragem de 60 determinações por hora, para ambos tensoativos. O sistema foi aplicado em amostras de águas coletadas no rio Corumbataí, e os resultados obtidos com testes de adição e recuperação variaram entre 91 % e 105 %. Aplicando-se teste-t entre os resultados obtidos pelo procedimento proposto e pelos métodos de referência (aniônicos) e de validação (catiônicos), os resultados foram concordantes em nível de 95 % de confiança." / "In this work, development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters employing the multicommutation concept were proposed. Aiming to system miniaturization, reduction of reagents consumption and effluents generation, solenoids micro-pump and solenoids pinch valves were used for the fluids propulsion and for solutions management, respectively. These devices were controlled by a microcomputer equipped with an electronic interface based on the integrate circuit ULN2803A that was coupled to the printer output. As system detection was employed an spectrophotometer model HP8452A, a multichannel spectrophotometer with CCD array linear arrangement of photodetectors and a homemade LED based photometer comprising two LEDs (blue and red) as radiation source and a photodiode (IPL10530DAL) as detector. In this case, the data acquisition was accomplished with a digital multimeter with serial out put RS232 employing a software wrote in VISUAL BASIC 3.0. The software comprised also routines to control the analysis module. Firstly, instrumentation and analytical procedures for independent determination of anionic and cationic surfactants in waters were developed. The same flow system comprised of four solenoid micro-pumps and it was employed for both surfactants. The procedure proposed for the determination of anionic surfactant was based on the substitution reaction of orange methyl (MO) by anionic surfactant (sodium dodecylbenzene sulfonate - DBS) to form an ion-pair with the cetyl pyridine (CPC) at pH 5.0. The proposed instrumentation allowed the achievement of a lineal response range between 1.4 x 10-6 mol L-1 and 1.4 x 10-5 mol L-1 (0.5 – 5.0 mg L-1) (R = 0.997, n = 7), a detection limit of 9.8 x 10-8 mol L-1 (0.034 mg L-1), a relative standard deviation of 0.8% (n = 11) for a reference solution containing 5.7 x 10-6 mol L-1 (2.0 mg L-1) DBS and sampling throughput of 60 determinations per hour. Results obtained applying the proposed procedure for domestic and industrial effluent samples were compared with those obtained using reference method and no significant differences at the 95 % confidence level was observed. For the determination of cationic surfactant in waters the procedure was developed based on the ternary complex formation between CPC, Fe (III) and chromazurol S at pH 4.5. The proposed system comprised a flow cell device with 40 mm optical path-length presented the following features: a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.34 – 10.2 mg L-1) (R = 0.999, n = 9); a detection limit of 1.0 x 10-7 mol L-1 (0.035 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC; and a sampling throughput of 72 determinations per hour. The procedure was applied to samples waters collected in the Piracicaba River. Using standard addition test recoveries between 91 % and 106 % were observed. The flow network for the sequential determination of anionic and cationic surfactants comprised two solenoid micro-pumps and six solenoid pinch valves. Employing the system proposed for the determination of anionic surfactants the folowing analytical characteristics: linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.35 – 10.5 mg L-1) (R = 0.9992, n = 7); a detection limit of 1.6 x 10-7 mol L-1 (0.056 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.5 mg L-1) DBS were observed. For cationic surfactants a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10?5 mol L-1 (0.34 - 10.2 mg L-1) (R = 0.9992, n = 7), a detection limit of 1.4 x 10-7 mol L-1 (0.05 mg L-1), a relative standard deviation of 0.5 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC were observed. In both cases, the reagents and sample consumption were 400 mL and 200 mL, respectively. The sampling throughput of 60 determinations per hour was achieved for both surfactants. The system was applied to waters samples from the Corumbataí River. The results obtained using the standard addition test presented recoveries between 91 % and 105 %. Applying t-test between the results obtained by the proposed procedures and those obtained using reference procedures showed that for anionic and cationic surfactants, the results were concordant at 95% confidence level."
192

Estudo do fluxo de ar em solos usando a técnica de injeção de ar em modelos físicos bidimensionais. / Study of the air flow in soils using the thecnique of air sparging in bidimensional physical model.

Scussiato, Talita 20 April 2012 (has links)
O método de injeção de ar é utilizado para a descontaminação de solos e lençóis freáticos contaminados com Compostos Orgânicos Voláteis (VOCs). O ar injetado no solo na zona saturada, ao subir para a zona não saturada, volatiliza os contaminantes. A eficiência da remediação por esse método está diretamente ligada à região de solo em que ocorre o fluxo de ar. Essa região é denominada de zona de influência e é afetada por vários fatores tais como: tipo e estrutura do solo, permeabilidade e pressão de injeção. No presente trabalho foram realizados estudos de fluxo de ar em solos saturados em um modelo físico bidimensional com o objetivo de avaliar a zona de influência formada. Os ensaios bidimensionais têm por finalidade a visualização dessa zona de influência; para isso foi utilizado um tanque transparente feito de placas de acrílico. Para a realização dos ensaios foram utilizados três tipos distintos de solo, uma areia natural denominada de Areia Osasco, uma areia comercial e uniforme (Areia do IPT) e um solo residual utilizado para criar as lentes de baixa permeabilidade. Também foram realizados ensaios de laboratório para a caracterização dos solos em estudo, tais como: curva de retenção, índice de vazios máximo e mínimo, granulometria, permeabilidade a água e ao ar. Os ensaios realizados no modelo (tanque) mostraram, como visto na literatura, que a granulometria e a estrutura do solo são as principais responsáveis pela formação de caminhos preferenciais de ar no solo. A zona de influência formada durante a injeção de ar nos ensaios com a Areia Osasco não foi simétrica devido à heterogeneidade do solo, já a formada nos ensaios com a Areia do IPT foi simétrica por causa da uniformidade do solo. A Areia do IPT apresentou uma zona de influência mais estreita do que a da Areia Osasco, isso ocorreu em função da menor porosidade da Areia Osasco, pois quanto menor a porosidade maior a tortuosidade e maior a expansão lateral. Os ensaios com as lentes de baixa permeabilidade mostraram que pequenas variações na configuração do solo podem influenciar a eficiência do método já que a região logo acima das lentes não foi atingida pelo ar. O aumento da pressão de injeção durante os ensaios fez com que mais canais de ar fossem formados causando um aumento do tamanho da zona de influência. / The method of air sparging is used for remediation of soil and groundwater contaminated with Volatile Organic Compounds (VOCs). In this process the air is injected into the soil in the saturated zone to ascend to the vadose zone and volatilizes the contaminants. The efficiency of air flow remediation is directly linked with the region of soil in which the flow occurs. This region is called as zone of influence and is affected by several factors such as: type and structure of the soil, permeability and pressure of injection. In the present work the air flow in saturated soils was investigated using a bidimensional physical model to evaluate the zone of influence formed. The objective of the tests was to obtain informations about zone of influence. A transparent tank made by acrylic plates was used. For these tests it was used three different types of soil: natural sand, called Osasco sand, a commercial and uniform sand called IPT sand and a residual soil used to create the lenses with low permeability. Laboratory tests such as water retention, minimum and maximum voids ratio, water and air permeability were performed to characterize the soils used in this study. Tests performed in the model (tank) showed, like those in the literature, that the particle size and soil structure are mainly responsible to create the preferential paths of air in soil. The zone of influence formed during the injection of air in the tests with Osasco sand was not symmetrical due to the heterogeneity of the soil; on the other hand the test performed with IPT sand was symmetrical due to its uniformity. The IPT sand showed a narrower zone of influence than Osasco sand, this was due to the lower porosity of the Osasco sand. Lower porosity imply in higher tortuosity and greater lateral expansion. Testes performed with low permeability lenses within the sand showed that small variations in the structure of the soil can affect the efficiency of the method because the region immediately above the lens is not reached by the air. The increase in the pressure of injection during the experiments induced the formation of more air channels causing an increase in the size of the zone of influence.
193

Otimização do processo de moldagem por injeção do ABS via metodos estatisticos

Cordova, Bruno Alexandro Bewzenko 30 January 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-07-24T12:23:29Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Bruno Alexandro Melo Cordoba.pdf: 5568473 bytes, checksum: b7b2a5b911d9cf8f3e1f1564ba6a257e (MD5) / Made available in DSpace on 2018-07-24T12:23:29Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Bruno Alexandro Melo Cordoba.pdf: 5568473 bytes, checksum: b7b2a5b911d9cf8f3e1f1564ba6a257e (MD5) Previous issue date: 2018-01-30 / A moldagem por injeção é um dos processos mais versáteis e amplamente empregada na manufatura de polímeros. Entretanto, há uma incidência de tantos fatores que tendem a influenciar o processo, ao ponto que um controle rigoroso dos parâmetros do processo se faz necessário para obtenção de peças com nível de qualidade adequada. Neste estudo, foram avaliadas as relações entre condições de processo, microestrutura e propriedades para o polímero Acrilonitrila-Butadieno-Estireno (ABS). Para tal, o ABS foi injetado em 9 condições, variando-se importantes parâmetros de injeção: temperatura do fundido (entre 210 e 240 ºC), temperatura do molde (45 – 65 ºC), pressão de compactação (150 - 250 bar) e velocidade de injeção (50 – 110 cm3/s). A partir dos resultados das propriedades mecânicas obtidas (Resistência sob Tração, Resistência ao Impacto, Módulo Elástico e Força Máxima sob Impacto), foram desenvolvidos 3 modelos de predição, determinados via Método Taguchi, Superfície de Resposta e Regressão Linear, sendo que o Método Taguchi apresentou maior eficácia. A partir dos modelos de previsão foram escolhidas 4 condições de injeção distintas da matriz ortogonal, no intuito de se verificar a precisão dos modelos criados. A microestrutura foi avaliada através da Microscopia Eletrônica de Varredura (MEV) de amostras fraturadas por impacto instrumentado e pela medição dos domínios elastoméricos (distribuição do tamanho do Polibutadieno) via análise de imagem. Por fim, foi aplicado o tratamento térmico de alívio de tensões, as propriedades mecânicas foram determinadas e por fim comparadas entre presença e ausência de tratamento térmico, onde foi observado que não se apresentou efeito considerável. / Injection molding is one of the most versatile and widely used processes in the manufacture of polymers. However, there is an incidence of so many factors that tend to influence the process, to the point that strict control of the process parameters is necessary to obtain pieces with adequate quality level. In this study, the relationships between process conditions, microstructure and properties for acrylonitrile-butadiene-styrene (ABS) polymer were evaluated. To do this, ABS was injected under 9 conditions, varying important injection parameters: melt temperature (between 210 and 240 ºC), mold temperature (45-65 ºC), compression pressure (150-250 bar) and injection rate (50-110 cm 3 / s). From the results of the mechanical properties obtained (Resistance under Traction, Impact Resistance, Elastic Modulus and Maximum Force under Impact), 3 prediction models were developed, determined by the Taguchi Method, Response Surface and Linear Regression, with the Taguchi Method was more effective. From the prediction models four different injection conditions of the orthogonal matrix were chosen, in order to verify the accuracy of the models created. The microstructure was evaluated by Scanning Electron Microscopy (SEM) of fractured samples by instrumented impact and by the measurement of the elastomeric domains (distribution of the polybutadiene size) through image analysis. Finally, the thermal treatment of stress relief was applied, the mechanical properties were determined and finally compared between the presence and absence of heat treatment, where it was observed that no considerable effect was observed.
194

Ligante ecofriendly à base de borracha natural para o processo de moldagem por injeção de pó de ferro

Escobar, Camila Ferreira January 2017 (has links)
O processo de moldagem de pós por injeção (MPI) é uma tecnologia relativamente recente e permite a fabricação de peças e componentes de diversos materiais, com a possibilidade de fabricar peças em larga escala. O processo MPI é composto por quatro etapas: mistura do pó com o material orgânico (ligante), moldagem por injeção, extração do ligante e sinterização. O ligante é um veículo temporário composto por polímeros e/ou ceras e sua função é possibilitar o escoamento da carga injetável para o molde durante a moldagem por injeção e após a moldagem este deve ser totalmente removido da peça. A maioria dos polímeros utilizados no ligante é oriunda do petróleo, que é uma fonte não renovável que gera sérios impactos ambientais. Neste estudo foi proposto a utilização de ligante à base de borracha natural, que além de ser proveniente de fonte renovável, confere elasticidade à peça moldada, que possibilita a fácil desmoldagem de peças com geometria complexa e pequenas espessuras. Também se analisou a substituição da parafina, que estudada em trabalhos anteriores em ligante para injeção de alumina com a borracha natural, pela cera de carnaúba na moldagem por injeção de pó de ferro metálico. Foram avaliados três ligantes à base de borracha natural e as ceras: (i) parafina, (ii) cera de carnaúba e (iii) parafina + cera de carnaúba e estudou-se o efeito da composição do ligante em cada etapa do processo MPI. Investigou-se as propriedades químicas e térmicas dos ligantes, o teor de pó admissível nas cargas injetáveis, as rotas de remoção do ligante por via térmica e solvente e as propriedades finais como retração linear, porosidade, microestrutura e resistência à flexão. As composições de ligante a base de borracha natural e cera de carnaúba proporcionaram melhores propriedades ao processo MPI. Nestas composições foi possível a moldagem por injeção de cargas injetáveis com maior teor de pó, apresentaram maior estabilidade reológica, em que a viscosidade apresentou baixa variação em relação à temperatura e maior estabilidade com o aumento do teor de pó. Além disso, foram as únicas amostras que não apresentaram defeitos durante a extração por solvente e apresentaram propriedades finais satisfatórias para o processo MPI de ferro. / The Powder Injection Molding process (PIM) is a relatively new technology and allows the manufacturing of parts and components of various materials, with the possibility of fabricating parts in microscale. The PIM process is composed of four steps: mix the powder with the organic material (binder), injection molding, extraction of the binder and sintering. The binder is a temporary vehicle composed of polymers and/or waxes and its function is to allow the flow of the feedstock into the mold during injection molding, and after molding this should be completely removed from the sample. Most of the polymers used in the binder are derived from petroleum, which is a non-renewable source that generates serious environmental impacts. In this study, it was proposed the use of binder based on polymer and wax from renewable sources that reduce the environmental impact. It was analyzed the substitution of paraffin, which was studied in previous studies with natural rubber, by the carnauba wax in the injection molding of the iron carbonyl. Were evaluated three binders based on polymer and wax: (i) paraffin, (ii) carnauba wax and (iii) paraffin wax carnauba wax and we studied the binder composition effect in each step of PIM process. The chemical and thermal binder properties, the critical powder volume concentration, the solvent and thermal debinding and the sintered properties were analyzed. As results, we found that the natural rubber and carnauba wax binder have better PIM process properties. In this binder was possible an injection molding with higher powder content, showing higher rheological stability, which the viscosity was more stable under temperature and powder content variation. Furthermore, the samples with this binder shown no defects after solvent debinding and suitable sintered properties for the iron PIM process.
195

Estabilização de Cu(III) em meio contendo peptídeos: estudos eletroquímicos e aplicações analíticas / Stabilization of Cu (III) in medium containing peptides: electrochemical studies and analytical applications

Lowinsohn, Denise 05 May 2003 (has links)
Neste trabalho são apresentados alguns resultados relacionados a estudos sobre o comportamento eletroquímico do Cu(II) em meio contendo diferentes peptídeos (tri, tetra e pentaglicina) em função da acidez utilizando-se voltametria cíclica. Os experimentos foram realizados em uma faixa de pH entre 7,0 e 10,0. Experimentos espectrofotométricos e coulométricos também foram feitos, ambos para se caracterizar as espécies de Cu(II) e Cu(III) em solução e provar a existência da degradação dos complexos de Cu(III). Além disso, experimentos para esses sistemas também foram realizados em diferentes temperaturas utilizando eletrodo rotativo na configuração disco-anel. Estudos eletroanalíticos demonstraram a potencialidade de se empregar o sistema Cu(II)/Cu(III) no desenvolvimento de metodologia eletroanalítica para a determinação de sulfito. Neste contexto, um método amperométrico indireto para a determinação de sulfito em fluxo é proposto neste trabalho. O método baseia-se na medida amperométrica (OV vs Ag/AgCI (sat. NaCI)) do Cu(III) gerado quimicamente no processo de auto¬-oxidação do S(IV) em soluções de Cu(II)/tetraglicina na presença de traços de Ni(II) utilizando uma célula em fluxo com sistema adequado para separação de gases. A oxidação espontânea do complexo pelo oxigênio dissolvido e S(IV) é muito lenta ao contrário do que ocorre quando há traços de Ni(II). A faixa de trabalho foi de 20-100 µmoIL-1 com limite de detecção de 2µmoIL-1 (S/N=3). A repetibilidade para a determinação (100µmoIL-1) levou a um desvio de 4,9% (n = 38), valor superior aos encontrados na literatura para determinações de sulfito em vinho por FIA com detecção amperométrica indireta (1-4,6%), e a freqüência analítica foi de 40h-1, valor coerente com os dos outros métodos amperométricos. Ambas as análises de sulfito em amostras de vinhos e de sucos tiveram seus resultados comparados com aqueles obtidos utilizando-se o método padrão. / The electrochemistry of Cu(II) in aqueous solutions containing triglycine, tetraglycine and pentaglycine had been investigated at glassy carbon surfaces. Experiments were carried out in the pH range between 7.0 and 10.0. A correlation between voltammetric waves and the nature of the Cu(II) species involved in the electrochemical steps was performed. Spectrophotometric and coulometric studies were also done to characterise Cu(II) and Cu(III) species in solution and prove the existence of a degradation step related to Cu(III) complexes. Rotating ring-disc voltammetry was employed to follow this chemical step coupled to the electrode reaction, at three different temperatures. Data show that Cu(III)/triglycine species degrade, with faster kinetics, when the results are compared with those obtained for tetraglycine and pentaglycine. An indirect amperometric method for the determination of sulfite in a flow injection configuration is described. The method is based on the amperometric measurement (OV vs Ag/AgCI (sat. NaCI)) of Cu(III) chemically generated by the sulfite induced autoxidation of Cu(II)/tetraglycine complex in the presence of traces of Ni(II) with a manifold that incorporates flow extraction of sulfite as SO2 through a PTFE membrane. The operational range was 2µmoIL-1 with a detection limit of 2µmolL-1 (S/N = 3). The repeatability for the determination (100 2µmolL-1) was evaluated to be 4.9% (n = 20) and the analytical frequency was 40h-1. Results for 3 wines and 2 juices samples showed excellent agreement with those obtained by using a recommended procedure for sulfite analysis.
196

Estudo farmacológico, eletrofisiológico, imunocitoquímico e morfológico da injeção intravítrea de aciclovir em coelhos / Pharmacological, electrophysiological, immunocytochemical and morphological study of intravitreal injection of aciclovir in rabbits

Takahashi, Beatriz Sayuri 17 April 2017 (has links)
INTRODUÇÃO: A administração de aciclovir por via sistêmica é o tratamento de escolha para a necrose aguda de retina. Entretanto, por ser uma doença rapidamente progressiva, a injeção intravítrea de aciclovir ao diagnóstico pode ser utilizada como terapia adjuvante, enquanto o aciclovir sistêmico ainda não alcançou níveis terapêuticos na retina. Os objetivos deste estudo experimental foram determinar a meia-vida do aciclovir no vítreo após injeção intravítrea e determinar os efeitos funcionais e morfológicos do aciclovir na retina de coelhos saudáveis após injeção intravítrea do medicamento em diferentes doses. MÉTODOS: Foram utilizados 32 coelhos albinos da raça New Zealand (estudo farmacológico) e 86 coelhos pigmentados da raça Dutch Belted (30 no estudo eletrofisiológico, 36 no estudo morfológico com microscopia de luz e 20 no estudo morfológico com imuno-histoquímica). Para a determinação da meia-vida do aciclovir no vítreo, os 32 coelhos albinos receberam injeção intravítrea de aciclovir 1 mg e foram sacrificados nos dias 2, 9, 14 e 28. Para a avaliação funcional e microscopia de luz, os 66 coelhos pigmentados receberam três doses intravítreas de aciclovir (0,1; 1 ou 10 mg) no olho direito e soro fisiológico no olho esquerdo. Destes, 30 animais foram submetidos ao eletrorretinograma (ERG) antes da injeção e nos dias 2, 7 e 15 após a injeção. Para a análise histológica (microscopia de luz), 36 animais foram sacrificados 2, 7 e 15 dias após a injeção. Para imuno-histoquímica (apoptose, GFAP, DAPI e vimentina), os 20 coelhos pigmentados receberam injeção intravítrea de 1 e 10 mg de aciclovir e foram sacrificados após cinco dias. RESULTADOS: No estudo da meia-vida do aciclovir no vítreo, as concentrações médias de aciclovir no vítreo foram 0,25, 0,09, 0,06 e 0,08 ?g/ml, respectivamente 2, 9, 14 e 28 dias depois da injeção. Nos estudos eletrofisiológico e de microscopia de luz, os olhos que receberam injeção intravítrea de 0,1 mg de aciclovir não apresentaram alterações funcionais ou histológicas. Os olhos injetados com 1 mg de aciclovir apresentaram redução significativa da amplitude das ondas a e b no ERG e desalinhamento dos fotorreceptores na microscopia de luz. Estes achados regrediram no 15º dia. Os olhos que receberam injeção intravítrea de 10 mg de aciclovir apresentaram as mesmas alterações funcionais, mas que não regrediram após o 15º dia. À microscopia de luz, esses olhos apresentaram destruição da camada de fotorreceptores e desorganização de toda a retina. Na camada de células ganglionares houve áreas com ausência de células da retina interna. A imuno-histoquímica mostrou lesão das células de Müller e apoptose de fotorreceptores apenas nos animais injetados com 10 mg. CONCLUSÕES: A meia-vida do aciclovir no vítreo após injeção intravítrea é muito curta para a sua detecção em dias. Os resultados funcionais e morfológicos sugerem que a injeção intravítrea de aciclovir em coelhos causa alterações tóxicas dose e tempo dependentes nos fotorreceptores e nos neurônios pós-receptorais da retina. A dose de 0,1 mg de aciclovir parece ser segura para injeção intravítrea em coelhos e pode ser utilizada em modelos experimentais de uveíte ou retinite viral / OBJECTIVE: The gold standard for the treatment of acute retinal necrosis is the use of systemic intravenous acyclovir. Nevertheless, as a rapidly progressive disease, use of intravitreal acyclovir injection at the time of diagnosis may be a second therapy until the systemic acyclovir reaches therapeutic levels in the retina. The aim of this experimental study was to determine pharmacological levels of the drug in the vitreous within days and to determine the functional and morphologic effects of acyclovir in the retina of healthy rabbits, after intravitreal injections in different dosages. METHODS: We have used 32 albino New Zealand rabbits for the pharmacologic experiments and 86 pigmented Dutch Belted animals for electrophysiology, immunochemistry and morphology. Thirty rabbits were used for the electrophysiological study, 36 were used for the light microscopy morphology and 20 animals were used for immunochemistry morphology. For the half-life study, the 32 albino rabbits received a 1mg acyclovir intravitreal injection and they were euthanized at 2, 9, 14 and 28 days. For functional and morphologic evaluations, the 66 pigmented animals received one of 3 intravitreal dosages of acyclovir (0,1; 1 or 10 mg) in the right eye and saline in the left eye. For the functional evaluation, 30 pigmented animals underwent electroretinography before the injection and on days 2, 7 and 15 after the procedure. For the histology with light microscopy, 36 animals were euthanized on days 2, 7 and 15 after the injection. Twenty rabbits that received 1 and 10mg of acyclovir were euthanized on day 5 were used for the immunohistochemistry to evaluate apoptosis, with GFAP, DAPI and vimentin. RESULTS: For the pharmacology study, the mean acyclovir concentrations when 1?g/ml was injected into the vitreous were respectively 0,25; 0,09; 0,06 e 0,08?g/ml on days 2, 9, 14 and 28 after injected. The eyes that received 0,1 mg acyclovir showed no functional or histological alterations. The eyes injected with 1 mg acyclovir had significant reduction on a and b waves amplitude and photoreceptor misalignment, which regressed on day 15. The 10mg injected eyes, showed the same electrophysiology changes. The retinas of those animals had photoreceptor layer destruction and total retina disorganization. In the ganglion cell layer, there were areas of absence of internal retinal cells. The immunohistochemistry showed Müller cells lesion and photoreceptor apoptosis in the 10mg animals. CONCLUSIONS: Acyclovir half-life is too short for its detection within days. The functional and morphological results suggest that the intravitreal acyclovir injection in rabbits cause toxic changes that are dose and time dependent on photoreceptors and post-receptor neurons in the retina. The 0,1 mg acyclovir dosage seems to be safe for intravitreal use in rabbits and may be studied in experimental models of viral uveitis or retinitis
197

Resistência à flexão e microestrutura de vidro-cerâmicas feldspáticas processadas por injeção em moldes à alta temperatura / Flexural strength and microstructure of feldspathic glass-ceramics processed by high-temperature injection molding

José Bernardo Fragoso Costa 21 December 2009 (has links)
Enquanto os métodos tradicionais de processamento de restaurações cerâmicas tornaram-se notórios por sua complexidade, as técnicas mais modernas vêm privilegiando a simplicidade de execução e a automação. Dentre estas, destaca-se a injeção em moldes, que recentemente, foi associada a métodos CAD-CAM. Estudos anteriores demonstraram a viabilidade de utilização de um vidro feldspático de baixa expansão térmica, Alpha (Vita Zahnfabrik), para injeção, porém, faltam informações quanto às propriedades mecânicas e a microestrutura deste material quando submetido à injeção. Os objetivos deste estudo são: produzir pastilhas vidrocerâmicas para injeção a quente a partir de Alpha e da mistura deste vidro com partículas de alumina e zircônia; avaliar a resistência à flexão dos materiais processados, e compará-la a um material compatível existente no mercado (PM9 - Vita Zahnfabrik); estudar a estrutura microscópica dos materiais e correlacioná-la com suas propriedades mecânicas; identificar por meio de difração de raios X a formação de fases cristalinas durante as diferentes etapas de processamento. A injeção aumentou a resistência do vidro Alpha devido à redução na quantidade e tamanho dos defeitos internos, principalmente porosidades. Apesar de ter sido observada nucleação de cristais nos dois materiais, durante o processamento, não foi possível determinar de que forma este fenômeno afetou as propriedades mecânicas dos materiais. Não foi detectada alteração no padrão de distribuição das fases cristalinas observadas em microscópio eletrônico de varredura antes e depois da injeção. Não foi verificada diferença estatística significante entre a resistência à flexão de Alpha injetado e PM9. A adição de partículas de alumina e zirconia ao vidro Alpha provocou redução da resistência, devido à formação de aglomerados durante a confecção das pastilhas e a incapacidade da injeção em dispersá-los. Tais aglomerados funcionaram como concentradores de tensões, enfraquecendo o material. / While traditional processing routes in the fabrication of ceramic restorations became notorious for their complexity, modern techniques have been priviledging simplicity and automation. High-temperature injection molding is a clear example, and recently has been associated to CAD-CAM technology. Studies demonstrated the use of a low thermal expansion feldspathic glass (Alpha, Vita Zahnfabrik) for injection, although more information is needed in terms of mechanical properties and microstructure of this material after being submitted to injection. The objectives of this study are: produce Alpha glass-ceramic ingots and Alpha with alumina and zirconia particles ingots for injection; evaluate flexural strength of the processed materials and compare it to a compatible product (PM9-Vita Zahnfabrik); study microstructure of the materials and correlate it to their mechanical properties; identify the existing cristalline phases at different processing stages with X-ray diffraction. Injection increased mechanical properties of Alpha glass due to reduction in porosity of the material. Despite the observation of crystal nucleation on both materials during processing, a clear correlation of this phenomenon and mechanical behavior could not be made. No alterations on the pattern of the crystalline phase distribution due to injection were observed on scanning electron microscope images. Flexural strength did not vary significantly between injected Alpha and PM9. The addittion of alumina and zirconia particles resulted in poorer mechanical results due to agglomerate formation during ingot fabrication and the incapacity of its dispersion trough injection. These agglomerates worked as stress concentrators, weakening the material.
198

Adsorção da Di-2-Piridil Cetona Saliciloilhidrazona (DPKSH) em resina Ira 402 : aplicação na determinação espectrofotométrica de íons Cu(II) por análise por injeção em fluxo (FIA) após separação e pré-concentração em fase sólida

Garcia, Samara January 2009 (has links)
Orientadora: Ivanise Gaubeur / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-graduação em Ciência e Tecnologia/Química.
199

Estudo comparativo entre o Bevacizumabe intravitreo e a fotocoagulação a laser com oftalmoscopio binocular indireto na retinopatia da prematuridade / Comparative study between intravitreal Bevacizumab or laser photocoagulation with binocular indirect ophthalmoscope in retinopathy of prematurity

Marquez, Tatiana Vieira de Brito 06 July 2010 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-02-20T15:09:52Z No. of bitstreams: 2 Dissertação - Tatiana Vieira de Brito Marquez - 2010.pdf: 2722177 bytes, checksum: d3f571bcc9c3e44cf51b9d4539e6191d (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-02-20T15:10:12Z (GMT) No. of bitstreams: 2 Dissertação - Tatiana Vieira de Brito Marquez - 2010.pdf: 2722177 bytes, checksum: d3f571bcc9c3e44cf51b9d4539e6191d (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-02-20T15:10:12Z (GMT). No. of bitstreams: 2 Dissertação - Tatiana Vieira de Brito Marquez - 2010.pdf: 2722177 bytes, checksum: d3f571bcc9c3e44cf51b9d4539e6191d (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2010-07-06 / OBJECTIVES: To compare the response of bevacizumab and the response of the laser photocoagulation with indirect binocular ophthalmoscope (IBO) in infants with retinopathy of prematurity (ROP) stages II or III. METHODS: Data collection was performed in the neonatal intensive care unit of the Hospital Materno Infantil, from May to November 2009. Preterm infants with ROP stages II or III, with or without the plus disease were included. They were divided into two groups: on group I, an intra-vitreous injection of bevacizumab was performed and on group II, laser photocoagulation with IBO was performed. RESULTS: In group I, from the 20 eyes that underwent the application of bevacizumab, there was total regression of ROP with one application in 14 eyes, being 4 eyes with complete regression with two doses of bevacizumab, and 2 eyes with total regression after two applications of bevacizumab and one application of laser. On group II, from the 20 eyes treated with laser photocoagulation with IBO, there was total regression of ROP with laser therapy in 14 eyes and there was total regression with two laser sessions in 6 eyes. CONCLUSION: Bevacizumab is effective if compared to laser photocoagulation in ROP stages II and III. / OBJETIVOS: Comparar a resposta terapêutica do bevacizumabe intravítreo com à resposta da fotocoagulação a laser com oftalmoscópio binocular indireto, em prematuros portadores de retinopatia da prematuridade estágios II ou III. MÉTODOS: A coleta de dados foi realizada na UTI neonatal do Hospital Materno Infantil, no período de maio a novembro de 2009. Foram incluídos os prematuros com retinopatia da prematuridade graus II ou III, com ou sem doença plus. Estes foram divididos em dois grupos: no grupo I foi realizada a injeção intra-vitrea de bevacizumabe, no grupo II foi realizada a fotocoagulação a laser com oftalmoscópio binocular indireto. RESULTADOS: No grupo I, dos 20 olhos incluídos, houve regressão total da retinopatia da prematuridade com uma aplicação de bevacizumabe em 14 olhos, regressão total com duas aplicações em 4 olhos e regressão total após duas aplicações de bevacizumabe e uma aplicação de laser em 2 olhos. No grupo II, dos 20 olhos tratados com fotocoagulação a laser com oftalmoscópio binocular indireto, houve regressão total da retinopatia da prematuridade com uma sessão em 14 olhos e houve regressão total com duas sessões em 6 olhos. CONCLUSÃO: O bevacizumabe é tão eficiente quanto a fotocoagulação a laser na retinopatia da prematuridade nos estágios II e III.
200

Projeto e desenvolvimento de um sensor MAP de pressão e temperatura em LTCC para aplicações automotivas. / Design and development of a MAP pressure and temperature sensor for automotive applications.

Paulo Fracalossi Ciampa 03 June 2011 (has links)
Este trabalho apresenta um módulo sensor de pressão absoluta do duto de admissão (MAP) para aplicações automotivas desenvolvido em substrato cerâmico LTCC. Em um veículo com sistema de injeção eletrônica de combustível, o sensor MAP informa a unidade de controle do motor sobre a pressão no duto de admissão permitindo o cálculo da vazão de ar e o ajuste da injeção de combustível. O sensor desenvolvido possui circuitos eletrônicos para a aquisição de sinais analógicos e digitais, realiza o condicionamento de sinal, a calibração e compensação de temperatura através de processamento digital, que permitem a indicação de pressões de 0 a 100kPa na faixa de temperaturas de -40 a +125ºC. Utilizou-se um elemento sensor de pressão piezorresistivo com membrana micro fabricada em silício e um sensor resistivo de temperatura. São apresentadas: a topologia do circuito, a construção, caracterização e testes. O protótipo apresenta precisão melhor do que 1,5% FE em pressão e 0,5% em temperatura. O teste de diferentes sensores de pressão e diferentes funções de transferência é facilmente realizado através de um circuito versátil que permite a alteração via programa. A montagem em cerâmica LTCC é realizada e é desenvolvida uma técnica de montagem do sensor de pressão MEMS em flip-chip, com excelentes resultados. Finalmente, é apresentado o teste em operação real em um veículo. / This paper presents a manifold absolute pressure (MAP) sensor module developed on LTCC substrate. In electronic fuel injection systems, a MAP sensor measures the vacuum at the engine intake manifold, allowing the electronic control unit to calculate mass flow and control the fuel injection. The sensor developed is composed by electronic circuits for analog signal acquisition and generation, digital signal processing and features software calibration and temperature-compensated pressure indications from 0 to 100kPa in the -40 to +125ºC temperature range. It is presented the assembly of a MEMS silicon pressure sensor and a thermistor on ceramic substrate and also the circuit topology, construction, characterization and tests. The prototype exhibits full scale accuracy better than 1.5% for pressure and 0.5% for temperature measurements. Tests are easily performed with different pressure sensors and different transfer functions due to a versatile circuit which enables software updates. The assembly on LTCC ceramic substrate is performed and an innovative flip-chip assembly technique is developed for MEMS pressure sensors, with excellent results. Finally, it is presented the test on a real vehicle.

Page generated in 0.0404 seconds