• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 90
  • 72
  • 9
  • 8
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 204
  • 120
  • 69
  • 53
  • 51
  • 32
  • 31
  • 31
  • 28
  • 27
  • 27
  • 22
  • 20
  • 19
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Eletrorretinograma de padrão reverso macular e multifocal e tomografia de coerência óptica em olhos suspeitos de glaucoma e glaucomatosos com perda de hemicampo / Macular and multifocal pattern electroretinogram and fourrier domain optical coherence tomography in glaucoma suspects and glaucomatous eyes with hemifield loss

Kreuz, André Carvalho 25 November 2016 (has links)
Objetivos: Avaliar a capacidade do eletrorretinograma de padrão reverso (PERG) macular e multifocal (mf) de diferenciar pacientes com suspeita de glaucoma (SG) e glaucoma com defeito de campo hemianópico (GH) de controles, comparar a capacidade de discriminação do PERG e tomografia de coerência óptica (TCO) fourrier domain, e avaliar a relação entre as medidas do PERG e TCO. Métodos: Medidas do campo visual (CV) computadorizado, respostas do PERG transiente e modo estacionário e PERGmf foram obtidos dos SG (n=14, 24 olhos), GH (n=5, 7 olhos) e controles (n=19, 22 olhos). Os seguintes parâmetros de TCO foram investigados: camada de fibras nervosas da retina peripapilar (CFNRpp), espessura total da mácula e espessuras das camadas segmentadas da mácula. As medidas foram analizadas utilizando-se modelos lineares de efeito misto. Também foi avaliada a relação entre as medidas e a performance diagnóstica de cada tecnologia. Resultados: Comparado aos controles, a média do tempo de pico de P50 da resposta do PERG transiente estava reduzida nos SG e GH, enquanto que a fase, a amplitude do modo estacionário e respostas do PERGmf estavam anormais apenas no GH. A média das medidas da TCO de espessura macular e da CFNRpp nos SG e GH diferiram significativamente dos controles. Uma significativa relação foi observada entre o PERG e a maior parte dos dos parâmetros do CV central e TCO. A análise por regressão e componentes principais revelou que a TCO de nervo óptico e mácula, assim como o PERG transiente e PERGmf tiveram estatisticamente capacidade similar em discriminar os SG dos controles. Conclusões: Os parâmetros do PERG e da TCO podem estar anormais, com significativa relação entre as medidas, em uma porcentagem alta de olhos com SG com CV normal. Nossos achados sugerem que as duas tecnologias podem ser úteis e complementares na detecção precoce de glaucoma / Purpose: To evaluate the ability of macular and multifocal (mf) pattern electroretinogram (PERG) to differentiate glaucoma suspects (GS) and glaucoma with hemifield loss (GHL) from controls, to compare the discrimination ability of PERG and fourier-domain optical coherence tomography (fdOCT), and to assess the relationship between PERG and fdOCT measurements. Methods: Standard automated perimetry (SAP), steady-state and transient PERG responses and mfPERG measurements were obtained from GS (n=14, 24 eyes), GHL (n=5, 7 eyes) and controls (n=19, 22 eyes). The following fdOCT parameters were investigated: circumpapillary retinal nerve fiber layer (cpRNFL), full-thickness macula, and segmented macular layer thicknesses. Measurements were compared using mixed effects linear models. The relationships between measurements and the diagnostic performance of each technology were also assessed. Results: Compared to controls, average P50 peak time transient PERG responses were reduced in GS and GHL, whereas average phase and amplitude steady-state and mfPERG responses were abnormal only in GHL. The average fdOCT-measured cpRNFL and macular thickness measurements in GS and GHL differed significantly from controls. A significant relationship was found between PERG and most fdOCT or central SAP sensitivity parameters. Principal component regression analysis revealed that optic disc and macular OCT parameters, along with mfPERG and transient PERG parameters had statistically similar ability to discriminate GS from controls. Conclusions: PERG and OCT parameters may be abnormal, with significant correlations between measurements, in a high percentage of GS eyes with normal SAP. Our findings suggest that both technologies may be helpful and complementary in early glaucoma detection
32

Late in-the-bag intraocular lens dislocation after cataract surgery – a 15 Yearfollow up study at Örebro University Hospital between 2003 and 2018.

Svanström, Diedrik January 2019 (has links)
Introduction: Cataract surgery, is nowadays the most common surgical procedure performedin Sweden. Late in-the-bag intraocular lens dislocation (LITBILD), occurring many yearsafter uneventful surgery, is due to progressive zonular weakness and capsular shrinkage.Known risk factors include among others pseudoexfoliations (PXF), high myopia andprevious vitreoretinal surgery. LITBILD has been reported with an increasing frequency inrecent years. Thus, there is a value in further investigating this patient group and describerelated risk factors. Aim: Determine the 15-year cumulative risk of LITBILD after standard cataract surgery2003 in Örebro and describe possible risk factors causing LITBILD. Method: Retrospective nested case-control study examining patients who underwent cataractsurgery with phacoemulsification in 2003 at Örebro University Hospital. To locate patientswithin that group who sustained LITBILD ICD10 diagnosis codes relating to LITBILDcovering years 2003-2018 were assessed. Each case was matched with two controls ofidentical sex and age. Results: The LITBILD group was 9 patients out of 1499 operated with median age atLITBILD of 80 years (range 57-82). Median time between cataract surgery and LITBILDwas 134 months (range 39-167). Glaucoma before and/or after cataract surgery and highintraocular pressure before surgery were independently statistically significant risk factors forLITBILD. Conclusion: Patients who underwent cataract surgery 2003 had a cumulative risk of 0.6% todevelop LITBILD. 78% of patients with dislocation had one or more of the risk factorsstudied whilst the control group represented 40% (p=0.08).
33

Long-term results of phakic refractive lenses for correction of myopia and hyperopia /

Koivula, Annemari, January 2007 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2007. / Härtill 4 uppsatser.
34

Curva diária e valores da pressão intraocular obtidos com tonômetro de rebote em equinos hígidos da raça crioula (Equus caballus)

Bacchin, Angela Beatriz de Oliveira January 2018 (has links)
A tonometria é de extrema importância durante o exame oftálmico, pois auxilia no diagnóstico e no acompanhamento do glaucoma e de inflamações intraoculares. No entanto, os valores da pressão intraocular podem sofrer influência do momento do dia em que o exame é realizado. Objetivou-se avaliar a pressão intraocular (PIO) com tonômetro de rebote em equinos hígidos da raça Crioula em diferentes horários do dia. Foram avaliados ambos os olhos de 25 cavalos da raça Crioula, machos ou fêmeas, subdivididos em três categorias de diferentes idades designadas por GI: nove animais (3-5 anos de idade), GII: oito animais (6-8 anos de idade) e GIII: oito animais (9-16 anos de idade). Previamente à tonometria foram realizados teste lacrimal de Schirmer, biomicroscopia com lâmpada de fenda, prova da fluoresceína e oftalmoscopia indireta em todos os equinos. Num mesmo dia foram realizadas sete aferições da PIO (às 6, 9, 12, 15, 18, 21 e 24 horas). A avaliação estatística utilizou o teste T de Student quando haviam dois grupos de comparações, e o teste de análise de variância (ANOVA) para as variáveis PIO, horário de aferição (tempo) e categoria de idade. O valor médio da pressão intraocular obtido foi de 28,4±3,7 mmHg considerando todos os animais avaliados. Os valores médios da pressão intraocular para os equinos de GI, GII e GIII foram 29,2±3,5 mmHg, 28,4±4,3 mmHg e 27,7±3,2 mmHg, respectivamente. Não houve diferença estatisticamente significativa entre os olhos direito e esquerdo (p= 0,257), nem entre sexos (p= 0,284). Quando comparadas as idades, a PIO média foi significativamente maior nos indivíduos jovens (p= 0,012). Não houve diferença estatisticamente significativa entre os diferentes horários do dia (p= 0,560). Os valores da PIO aferidos com o tonômetro de rebote em equinos da raça Crioula sofreram influência da idade. Os valores da pressão intraocular média obtidos com tonômetro de rebote em equinos hígidos não variaram em diferentes horários ao longo do dia. / The tonometry is extremely important during ophthalmic examination, because assists in the diagnosis and follow-up of glaucoma and intraocular inflammation. However, intraocular pressure values may be influenced by the moment of the day it is measured. The objective was to evaluate the intraocular pressure (IOP) with Rebound Tonometer in healthy horses of the Crioula breed at different times of the day. Twenty five horses, male or female, were divided into three groups by age: Group I: nine horses (3-5 years old), Group II: eight horses (6-8 years old), and Group III: eight horses (9-16 years old). Ophthalmic examination was performed previously by Schirmer Tear Test, slit lamp biomicroscopy, fluorescein test and indirect ophthalmoscopy in all horses. Seven measurements of intraocular pressure were assessed on the same day (at 6, 9, 12, 15, 18, 21 and 24 hours).The Student’s T Test statistical analysis was used when there was two groups of comparisons, and the Analysis of Variance (ANOVA) was used for variables IOP, measurement time and age category. The average value of intraocular pressure was 28.4 ± 3.7 mmHg considering all the animals evaluated. The mean intraocular pressure for groups I, II and III were 29.2 ± 3.5 mmHg, 28.4 ± 4.3 mmHg and 27.7 ± 3.2 mmHg, respectively. There was no statistically significant difference between right and left eyes (p = 0.257), nor between genders (p = 0.284). When compared to the ages, the average IOP was significantly higher in young animals (p = 0.012). There was no statistically significant result between the different times of the day (p = 0.560). The IOP values measured with rebound tonometer in Crioula horses were influenced by age. The average intraocular pressure values obtained with rebound tonometer in healthy horses did not change with time of day.
35

Testes oftalmológicos e poder dióptrico da lente intraocular em lobo guará (Chrysocyon brachyurus - Illinger, 1815)

Barros, Rodrigo. January 2018 (has links)
Orientador: Cláudia Valéria Seullner Brandão / Resumo: Este trabalho tem como objetivo descrever valores oftalmológicos, determinar o poder dióptrico da lente intraocular (LIO), além de comparar os olhos considerando a lateralidade e sexo nesta espécie e avaliar a hipótese que os valores são similares com o cão. O lobo guará (Chrysocyon brachyurus) encontra-se na lista vermelha de espécies em extinção do The International Union for Conservation of Nature (IUCN), de animais em quase ameaça. As principais causas são a caça indiscriminada e atropelamentos. A espécie possui hábitos noturnos e crepusculares, o que torna a visão um dos seus sentidos mais importantes. Diante disso, a pesquisa avaliou 13 lobos guarás (26 olhos), hígidos, com idade superior a um ano, machos e fêmeas com peso entre 25 e 30kg. Foram realizados os seguintes testes oftalmológicos: teste lacrimal de Schirmer (TLS), estesiometria, tonometria e paquimetria. Adicionalmente, foi realizada a ultrassonografia modo A (US-A), ceratometria e a medida da distância limbo-limbo; e o calculo da dioptria lenticular. Foram obtidos os seguintes valores médios para os testes oftalmológicos: TLS 19,15±3,58mm/min; estesiometria 0,96±0,31mm; tonometria 13,96±4,75mmHg; paquimetria 528,50±55,13µm; distância limbo-limbo 18,08±1,32mm; comprimento axial 21,04±0,55mm e profundidade de câmara anterior 4,63±0,33mm; e cetarometria média 37,21±1,32D. Referente às fórmulas: SRK/T 34,04±1,66D; Hoffer Q 36,31±1,83D; Holladay I 35,42±1,88D, Haigis 42,19±2,29D e Holladay II 35,00±1,65D. Foram d... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to describe ophthalmologic values, to determine the dioptric power of the intraocular lens (IOL), and to evaluate the results compared to the laterality of the eyes and the sex of maned wolves and evaluate the hypothesis that the values are similar to dogs. The maned wolf (Chrysocyon brachyurus) is in the red list of endangered species of the International Union for Conservation of Nature (IUCN), a near-threatened animal. The main causes are indiscriminate hunting and trampling. The species has nocturnal and crepuscular habits, which makes the vision one of its most important senses. In this research were evaluated 13 maned wolfs (26 eyes), healthy, captive wolves, aged from 1 to 8 years, four males and nine females with weight between 25 and 30kg. The following ophthalmological tests were performed: Schirmer's lachrymal test (SLT), esthesiometry, tonometry and pachymetry. Additionally, ultrasound mode A, keratometry and measurement of limbo-limbo distance were performed; and the calculation of lenticular diopter. Values of the ophthalmological tests were obtained: SLT 19,15±3,58mm/min; esthesiometry 0,96±0,31mm; tonometry 13,96±4,75mmHg; pachymetry 528,50±55,13μm; limbo-limbo distance 18,08±1,32mm; axial length 21,04±0,55mm and anterior chamber depht 4,63±0,33mm. Cetarometry average 37,21±1,32D. The formulas: SRK/T 34,04±1,66D; Hoffer Q 36,31±1,83D; Holladay I 35,42±1,88D, Haigis 42,19±2,29D and Holladay II 35,00±1,65D. The ophthalmologic variables and diopt... (Complete abstract click electronic access below) / Doutor
36

Comparação entre o tonômetro de rebote (Tonovet) e o novo tonômetro de aplanação (Tono-pen a via) durante curva diurna da pressão intraocular de coelhos adultos. / Comparison of a rebound (tonovet) and an new applanation tonometer (tonopen-avia) for diurnal curves of intraocular pressure in adults rabbits

Pereira, Fabiana Quartiero January 2010 (has links)
A determinação da pressão intraocular (PIO) é fundamental no exame oftálmico. Atualmente, novos tonômetros, baseados em diferentes princípios, estão sendo continuamente desenvolvidos. O objetivo deste estudo foi estabelecer os valores de referência da PIO de coelhos adultos, sem efeito de tranquilizantes, mensurada com o tonômetro de rebote (Tonovet) e o de aplanação (Tono-Pen Avia). Também foi preconizada a mensuração da PIO ao longo do dia nesta espécie e a comparação dos resultados obtidos com os dois tonômetros. A PIO foi aferida ao longo do dia (6h, 9h, 12h, 15h e 18h) em 38 coelhos (76 olhos) da raça Nova Zelândia Branca, adultos, com idade média de seis meses, machos ou fêmeas, com massa corporal média de 3,5kg. Previamente, foi realizado teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta em todos os animais. A tonometria de rebote foi realizada primeiro e, decorridos 10 minutos, foi instilado colírio anestésico e realizada a tonometria de aplanação. A PIO obtida utilizando as duas técnicas foi comparada estatisticamente. A média da PIO com o Tonovet foi de 9,51 ± 2,62 mmHg (variação de 3- 23mmHg) e 15,44 ± 2,16 mmHg (variação de 8 – 26mmHg) com o Tono-Pen Avia. Houve diferença estatística significante entre os valores obtidos com os dois tonômetros (P < 0,001). A relação entre os dois tonômetros foi representada através da equação de regressão linear: y = 0,4923x + 10,754 (y= Tonovet e x= Tono-Pen Avia). No início do dia foram registradas PIOs mais elevadas, mas a média dos valores ao longo do dia, com ambos os aparelhos, foi estatisticamente o mesmo (p = 0,086). O valor do coeficiente de correlação obtido foi r2= 0,357. Os resultados demonstram que o Tono-Pen Avia é mais variável e superestima a PIO de coelhos quando comparado ao Tonovet. Nas primeiras horas do dia, a PIO de coelhos foi mais alta que nos demais horários, independentemente do tonômetro utilizado. / The determination of intraocular pressure (IOP) is crucial in eye examination. Currently, new tonometers based on different principles are being continuously developed. The objective was to establish reference values of IOP of adults rabbits without the effect of tranquilizers, utilizing the rebound tonometer (Tonovet ) and the applanation tonometer (Tono-Pen Avia) for measurements. It also aimed to advocate the measurement of IOP throughout the day in this species and compare the results obtained with the two tonometers. The IOP was measured throughout the day (6h, 9h, 12h, 15h and 18h) in 38 New Zealand White rabbits (76 eyes), adults, males or females, with mean weight of 3.5kg and an average age of six months. Previously, the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp and direct ophthalmoscopy were performed in all animals. First, the rebound tonometry was performed and after a minimum of 10 minutes anesthetic drops were instilled and applanation tonometry was carried out. IOP obtained using the two techniques was compared by statistical analysis. The average IOP was 9.51 ± 2.62 mmHg (range 3 - 23 mmHg) and 15.44 ± 2.16 mmHg (range 8 – 26mmHg), with Tonovet and Tono-Pen Avia, respectively. Statistic significant difference between the two tonometers was (P <0.001). The linear regression equation that describes the relationship between the two tonometers was: y = 0.4923 x + 10.754 (y= Tonovet e x= Tono-Pen Avia). Earlier in the day, higher IOPs were recorded, but the average behavior of IOP throughout the day with both devices was statistically the same (p = 0.086). The value of the correlation coefficient was r2 = 0.357. The results show that the Tono-Pen Avia is more variable and overestimates the IOP of rabbits when compared with the Tonovet. In the early hours, the IOP of rabbits was higher than at other times, regardless of the tonometer used.
37

Avaliação da pressão intraocular em chinchilas (chinchilla Lanigera) de diferentes faixas etárias utilizando tonometria de rebote

Claros Chacaltana, Flor Diana Yokoay January 2013 (has links)
A aferição da pressão intraocular (PIO) é fundamental durante o exame oftálmico. Objetivou-se estabelecer os valores de referência da PIO de chinchilas de diferentes faixas etárias utilizando o tonômetro de rebote. A PIO foi aferida ao longo do dia às 7, 12 e 19 horas utilizando o tonômetro de rebote (Tonovet®). As chinchilas foram subdivididas em três grupos com 12 animais cada, considerando as idades, designados por GI (animais com idade entre dois a seis meses), GII (com idade entre 20 e 34 meses) e GIII (animais com idade entre 37 e 135 meses). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos os animais. O valor médio da pressão intraocular encontrado foi 2,49 ± 0,56 mmHg, os valores médios para o grupo I foi de 2,47±0,581 mmHg, no grupo II de 2,47±0,581 mmHg e no grupo III de 2,51±0,531 mmHg. Não foram encontradas diferenças significativas entre a idade e a PIO (P = 0,756). Não foram encontradas diferenças significativas entre as horas do dia e a PIO (P = 0,415). Não foram encontradas diferenças significativas entre os sexos (P = 0,857). Os valores da PIO em chinchilas não sofrem alterações decorrentes do sexo e da idade dos animais. Não ocorre influência do ritmo circadiano na PIO de chinchilas. / The assessment of intraocular pressure (IOP) is essential for the ocular examination. The purpose of this study was to establish reference values of intraocular pressure chinchillas (Chinchilla lanigera) of different age groups. Thirty-six Chinchillas were divided in three groups of 12 animals each, considering the ages designated by GI (animals aged two to six months), GII (aged between 20 and 34 months) and GIII (animals aged between 37 and 135 months). Intraocular pressure was measured at 7, 12 and 19 hours. Tear production was measured, fluorescein test, slit-lamp biomicroscopy and indirect ophthalmoscopy in all animals and IOP was measured using the rebound tonometer (Tono Vet®) set on the P (undefined species) setting, with measurements obtained from each eye. No abnormalities were found on ophthalmic examination. The mean (±SD) of IOP was 2.49 ± 0.56 mmHg, with a range of 2-4 mmHg. The mean (±SD) of IOP for group I, II and III were 2.47 ± 0.581 mmHg, 2.47 ± 0.581 mmHg and 2,51 ± 0.531 mmHg, respectively. No significant differences were found between age and IOP and no significant differences were found between the hours of day and IOP. No significant differences were found between the genders. The IOP in chinchillas is unchanged between genders and age of the animals. The circadian rhythm is not influenced by IOP in chinchillas.
38

Curva diária e valores da pressão intraocular obtidos com tonômetro de rebote em equinos hígidos da raça crioula (Equus caballus)

Bacchin, Angela Beatriz de Oliveira January 2018 (has links)
A tonometria é de extrema importância durante o exame oftálmico, pois auxilia no diagnóstico e no acompanhamento do glaucoma e de inflamações intraoculares. No entanto, os valores da pressão intraocular podem sofrer influência do momento do dia em que o exame é realizado. Objetivou-se avaliar a pressão intraocular (PIO) com tonômetro de rebote em equinos hígidos da raça Crioula em diferentes horários do dia. Foram avaliados ambos os olhos de 25 cavalos da raça Crioula, machos ou fêmeas, subdivididos em três categorias de diferentes idades designadas por GI: nove animais (3-5 anos de idade), GII: oito animais (6-8 anos de idade) e GIII: oito animais (9-16 anos de idade). Previamente à tonometria foram realizados teste lacrimal de Schirmer, biomicroscopia com lâmpada de fenda, prova da fluoresceína e oftalmoscopia indireta em todos os equinos. Num mesmo dia foram realizadas sete aferições da PIO (às 6, 9, 12, 15, 18, 21 e 24 horas). A avaliação estatística utilizou o teste T de Student quando haviam dois grupos de comparações, e o teste de análise de variância (ANOVA) para as variáveis PIO, horário de aferição (tempo) e categoria de idade. O valor médio da pressão intraocular obtido foi de 28,4±3,7 mmHg considerando todos os animais avaliados. Os valores médios da pressão intraocular para os equinos de GI, GII e GIII foram 29,2±3,5 mmHg, 28,4±4,3 mmHg e 27,7±3,2 mmHg, respectivamente. Não houve diferença estatisticamente significativa entre os olhos direito e esquerdo (p= 0,257), nem entre sexos (p= 0,284). Quando comparadas as idades, a PIO média foi significativamente maior nos indivíduos jovens (p= 0,012). Não houve diferença estatisticamente significativa entre os diferentes horários do dia (p= 0,560). Os valores da PIO aferidos com o tonômetro de rebote em equinos da raça Crioula sofreram influência da idade. Os valores da pressão intraocular média obtidos com tonômetro de rebote em equinos hígidos não variaram em diferentes horários ao longo do dia. / The tonometry is extremely important during ophthalmic examination, because assists in the diagnosis and follow-up of glaucoma and intraocular inflammation. However, intraocular pressure values may be influenced by the moment of the day it is measured. The objective was to evaluate the intraocular pressure (IOP) with Rebound Tonometer in healthy horses of the Crioula breed at different times of the day. Twenty five horses, male or female, were divided into three groups by age: Group I: nine horses (3-5 years old), Group II: eight horses (6-8 years old), and Group III: eight horses (9-16 years old). Ophthalmic examination was performed previously by Schirmer Tear Test, slit lamp biomicroscopy, fluorescein test and indirect ophthalmoscopy in all horses. Seven measurements of intraocular pressure were assessed on the same day (at 6, 9, 12, 15, 18, 21 and 24 hours).The Student’s T Test statistical analysis was used when there was two groups of comparisons, and the Analysis of Variance (ANOVA) was used for variables IOP, measurement time and age category. The average value of intraocular pressure was 28.4 ± 3.7 mmHg considering all the animals evaluated. The mean intraocular pressure for groups I, II and III were 29.2 ± 3.5 mmHg, 28.4 ± 4.3 mmHg and 27.7 ± 3.2 mmHg, respectively. There was no statistically significant difference between right and left eyes (p = 0.257), nor between genders (p = 0.284). When compared to the ages, the average IOP was significantly higher in young animals (p = 0.012). There was no statistically significant result between the different times of the day (p = 0.560). The IOP values measured with rebound tonometer in Crioula horses were influenced by age. The average intraocular pressure values obtained with rebound tonometer in healthy horses did not change with time of day.
39

Comparação entre o tonômetro de rebote (Tonovet) e o novo tonômetro de aplanação (Tono-pen a via) durante curva diurna da pressão intraocular de coelhos adultos. / Comparison of a rebound (tonovet) and an new applanation tonometer (tonopen-avia) for diurnal curves of intraocular pressure in adults rabbits

Pereira, Fabiana Quartiero January 2010 (has links)
A determinação da pressão intraocular (PIO) é fundamental no exame oftálmico. Atualmente, novos tonômetros, baseados em diferentes princípios, estão sendo continuamente desenvolvidos. O objetivo deste estudo foi estabelecer os valores de referência da PIO de coelhos adultos, sem efeito de tranquilizantes, mensurada com o tonômetro de rebote (Tonovet) e o de aplanação (Tono-Pen Avia). Também foi preconizada a mensuração da PIO ao longo do dia nesta espécie e a comparação dos resultados obtidos com os dois tonômetros. A PIO foi aferida ao longo do dia (6h, 9h, 12h, 15h e 18h) em 38 coelhos (76 olhos) da raça Nova Zelândia Branca, adultos, com idade média de seis meses, machos ou fêmeas, com massa corporal média de 3,5kg. Previamente, foi realizado teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta em todos os animais. A tonometria de rebote foi realizada primeiro e, decorridos 10 minutos, foi instilado colírio anestésico e realizada a tonometria de aplanação. A PIO obtida utilizando as duas técnicas foi comparada estatisticamente. A média da PIO com o Tonovet foi de 9,51 ± 2,62 mmHg (variação de 3- 23mmHg) e 15,44 ± 2,16 mmHg (variação de 8 – 26mmHg) com o Tono-Pen Avia. Houve diferença estatística significante entre os valores obtidos com os dois tonômetros (P < 0,001). A relação entre os dois tonômetros foi representada através da equação de regressão linear: y = 0,4923x + 10,754 (y= Tonovet e x= Tono-Pen Avia). No início do dia foram registradas PIOs mais elevadas, mas a média dos valores ao longo do dia, com ambos os aparelhos, foi estatisticamente o mesmo (p = 0,086). O valor do coeficiente de correlação obtido foi r2= 0,357. Os resultados demonstram que o Tono-Pen Avia é mais variável e superestima a PIO de coelhos quando comparado ao Tonovet. Nas primeiras horas do dia, a PIO de coelhos foi mais alta que nos demais horários, independentemente do tonômetro utilizado. / The determination of intraocular pressure (IOP) is crucial in eye examination. Currently, new tonometers based on different principles are being continuously developed. The objective was to establish reference values of IOP of adults rabbits without the effect of tranquilizers, utilizing the rebound tonometer (Tonovet ) and the applanation tonometer (Tono-Pen Avia) for measurements. It also aimed to advocate the measurement of IOP throughout the day in this species and compare the results obtained with the two tonometers. The IOP was measured throughout the day (6h, 9h, 12h, 15h and 18h) in 38 New Zealand White rabbits (76 eyes), adults, males or females, with mean weight of 3.5kg and an average age of six months. Previously, the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp and direct ophthalmoscopy were performed in all animals. First, the rebound tonometry was performed and after a minimum of 10 minutes anesthetic drops were instilled and applanation tonometry was carried out. IOP obtained using the two techniques was compared by statistical analysis. The average IOP was 9.51 ± 2.62 mmHg (range 3 - 23 mmHg) and 15.44 ± 2.16 mmHg (range 8 – 26mmHg), with Tonovet and Tono-Pen Avia, respectively. Statistic significant difference between the two tonometers was (P <0.001). The linear regression equation that describes the relationship between the two tonometers was: y = 0.4923 x + 10.754 (y= Tonovet e x= Tono-Pen Avia). Earlier in the day, higher IOPs were recorded, but the average behavior of IOP throughout the day with both devices was statistically the same (p = 0.086). The value of the correlation coefficient was r2 = 0.357. The results show that the Tono-Pen Avia is more variable and overestimates the IOP of rabbits when compared with the Tonovet. In the early hours, the IOP of rabbits was higher than at other times, regardless of the tonometer used.
40

Eletrorretinograma de padrão reverso macular e multifocal e tomografia de coerência óptica em olhos suspeitos de glaucoma e glaucomatosos com perda de hemicampo / Macular and multifocal pattern electroretinogram and fourrier domain optical coherence tomography in glaucoma suspects and glaucomatous eyes with hemifield loss

André Carvalho Kreuz 25 November 2016 (has links)
Objetivos: Avaliar a capacidade do eletrorretinograma de padrão reverso (PERG) macular e multifocal (mf) de diferenciar pacientes com suspeita de glaucoma (SG) e glaucoma com defeito de campo hemianópico (GH) de controles, comparar a capacidade de discriminação do PERG e tomografia de coerência óptica (TCO) fourrier domain, e avaliar a relação entre as medidas do PERG e TCO. Métodos: Medidas do campo visual (CV) computadorizado, respostas do PERG transiente e modo estacionário e PERGmf foram obtidos dos SG (n=14, 24 olhos), GH (n=5, 7 olhos) e controles (n=19, 22 olhos). Os seguintes parâmetros de TCO foram investigados: camada de fibras nervosas da retina peripapilar (CFNRpp), espessura total da mácula e espessuras das camadas segmentadas da mácula. As medidas foram analizadas utilizando-se modelos lineares de efeito misto. Também foi avaliada a relação entre as medidas e a performance diagnóstica de cada tecnologia. Resultados: Comparado aos controles, a média do tempo de pico de P50 da resposta do PERG transiente estava reduzida nos SG e GH, enquanto que a fase, a amplitude do modo estacionário e respostas do PERGmf estavam anormais apenas no GH. A média das medidas da TCO de espessura macular e da CFNRpp nos SG e GH diferiram significativamente dos controles. Uma significativa relação foi observada entre o PERG e a maior parte dos dos parâmetros do CV central e TCO. A análise por regressão e componentes principais revelou que a TCO de nervo óptico e mácula, assim como o PERG transiente e PERGmf tiveram estatisticamente capacidade similar em discriminar os SG dos controles. Conclusões: Os parâmetros do PERG e da TCO podem estar anormais, com significativa relação entre as medidas, em uma porcentagem alta de olhos com SG com CV normal. Nossos achados sugerem que as duas tecnologias podem ser úteis e complementares na detecção precoce de glaucoma / Purpose: To evaluate the ability of macular and multifocal (mf) pattern electroretinogram (PERG) to differentiate glaucoma suspects (GS) and glaucoma with hemifield loss (GHL) from controls, to compare the discrimination ability of PERG and fourier-domain optical coherence tomography (fdOCT), and to assess the relationship between PERG and fdOCT measurements. Methods: Standard automated perimetry (SAP), steady-state and transient PERG responses and mfPERG measurements were obtained from GS (n=14, 24 eyes), GHL (n=5, 7 eyes) and controls (n=19, 22 eyes). The following fdOCT parameters were investigated: circumpapillary retinal nerve fiber layer (cpRNFL), full-thickness macula, and segmented macular layer thicknesses. Measurements were compared using mixed effects linear models. The relationships between measurements and the diagnostic performance of each technology were also assessed. Results: Compared to controls, average P50 peak time transient PERG responses were reduced in GS and GHL, whereas average phase and amplitude steady-state and mfPERG responses were abnormal only in GHL. The average fdOCT-measured cpRNFL and macular thickness measurements in GS and GHL differed significantly from controls. A significant relationship was found between PERG and most fdOCT or central SAP sensitivity parameters. Principal component regression analysis revealed that optic disc and macular OCT parameters, along with mfPERG and transient PERG parameters had statistically similar ability to discriminate GS from controls. Conclusions: PERG and OCT parameters may be abnormal, with significant correlations between measurements, in a high percentage of GS eyes with normal SAP. Our findings suggest that both technologies may be helpful and complementary in early glaucoma detection

Page generated in 0.0709 seconds