• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 90
  • 72
  • 9
  • 8
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 204
  • 120
  • 69
  • 53
  • 51
  • 32
  • 31
  • 31
  • 28
  • 27
  • 27
  • 22
  • 20
  • 19
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Social economic status association with intraocular pressure in rural Alabama

Irby, Alice L. January 2009 (has links) (PDF)
Thesis (M.P.H.)--University of Alabama at Birmingham, 2009. / Title from first page of PDF file (viewed on June 11, 2009). Includes bibliographical references (p. 36-40).
62

Estudo clínico da facoemulsificação em cães, com e sem implante de lente intra-ocular em piggyback

Rodrigues, Georgia Nadalini [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T18:41:49Z : No. of bitstreams: 1 rodrigues_gn_dr_botfmvz.pdf: 4865487 bytes, checksum: 4d614b1bb25a841f92667f0c608bf5b7 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do presente estudo foi avaliar o comportamento do olho canino após a cirurgia para extração de catarata, com e sem implante de lente intra-ocular (LIO) em piggyback, frente a pressão intra-ocular, espessura e curvatura corneanas, densidade e área das células do endotélio da córnea. Empregaram-se, 25 animais da espécie canina de sexo, raça e idades variadas, portadores de catarata, subdivididos em 4 grupos designados por G1 (cães portadores de catarata imatura, com implante de LIO), G2 (cães portadores de catarata madura, com implante de LIO), G3 (cães portadores de catarata imatura, sem implante de LIO) e G4 (cães portadores de catarata madura, sem implante de LIO). A técnica cirúrgica foi a facoemulsificação bimanual. As avaliações da pressão intra-ocular, curvatura e espessura da córnea, foram aferidas antes do procedimento cirúrgico (0) enquanto que, as avaliações das densidade e área das células do endotélio corneano foram realizadas antes do procedimento cirúrgico (0) e nos tempos 7, 28 e 60 dias após o procedimento cirúrgico. A estatística utilizada foi a Análise de Perfil, seguida do método de Tukey para comparações múltiplas, com nível de significância de 5%. Os resultados não demonstraram diferença significativa entre os quatro grupos analisados, no entanto, houve diferença na comparação entre os olhos operados e os contra-laterais. A avaliação qualitativa realizada durante o pós-operatório demonstrou uma maior reação inflamatória e um maior índice de complicações entre os animais dos grupos 1 e 2. Concluí-se que não houve diferença entre os grupos, no entanto, demonstrou-se diferença entre o olho operado e não-operado. Entretanto, o pós-operatório dos animais dos grupos 1 e 2 revelou-se mais complicado, expressando uma reação inflamatória mais exacerbada e um maior índice de complicações. / The purpose of this study was to investigate the effects in intraocular pressure, central corneal thickness, corneal curvature, cellular density and area of corneal endothelium after surgery for cataract extraction with and without intraocular lens (IOL) implantation using piggyback technique in eyes of dogs. A total of 25 dogs were divided into 4 groups: Group 1 (dogs with immature cataract and with IOL implantation), Group 2 (dogs with mature cataract and with IOL implantation), Group 3 (dogs with immature cataract and without IOL implantation) and Group 4 (dogs with mature cataract and without IOL implantation). The surgical technique performed was bimanual phacoemulsification. Intraocular pressure, central corneal thickness and corneal curvature were measured before surgery (0) and at 3, 7, 14, 21, 28, 60 days of postoperative. Cellular density and area of corneal endothelium were measured before surgery and at 7, 28, 60 days of postoperative. Statistical analysis was performed using variance analysis (profile) and Tukey test for multiple comparison with significance at p<0.05. The 4 groups did not differ significantly with respect to parameters evaluated. There was, however, a significant difference between the two eyes (operated and nonoperated). However, the dogs of groups 1 and 2 had more complicate postoperative with more severe ocular inflammation and number of complications.
63

Mensurações do bulbo ocular e cálculo do poder dióptrico de lentes intraoculares em coelhos (Oryctolagus cuniculus), LINNAEUS, 1758)

Valinhos, Mayana Andréa Rodrigues [UNESP] 04 April 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-04-04Bitstream added on 2014-06-13T20:35:25Z : No. of bitstreams: 1 valinhos_mar_me_botfmvz.pdf: 604025 bytes, checksum: 99098100284f34af46bd3aaa890c8b1d (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O trabalho teve por objetivos determinar as dimensões oculares de coelhos, empregando ultrassonografia modo-A e ceratometria, a fim de utilizá-las como subsídios para calcular o poder dióptrico de lentes intraoculares, assim como, avaliar se existe diferença entre as mensurações oculares de machos e fêmeas, bem como entre olho esquerdo e olho direito em coelhos. Foram utilizados 58 animais do Grupo Genético Botucatu, divididos entre 30 fêmeas e 28 machos, com idade média de 85,8 ± 8,29 dias e peso médio de 2,3 ± 0,46 kg. O cálculo da lente intraocular foi realizado através do software Holladay IOL Consultant®. As fórmulas empregadas para o cálculo foram: Holladay II, Holladay I, Hoffer Q e SRK-T que calcularam um poder dióptrico médio para as lentes de 48,5 D; 50,27 D; 59,67 D e 49,24 D, respectivamente. A fórmula SRK-T mostrou-se estatisticamente semelhante às fórmulas Holladay II e Holladay I, enquanto as demais se mostraram diferentes entre si. Os parâmetros biométricos oculares avaliados, assim como o poder dióptrico calculado por uma mesma fórmula não apresentaram diferenças significativas com relação ao sexo e a lateralidade / The present study aimed to determine the dimensions of the rabbits eyes using A-mode ultrasound and keratometry, in order to use them as data for calculating the dioptric power of intraocular lenses, as well as assess whether there are differences of ocular measurements between males and females and between the left eye and right eye in rabbits. Fifty-eight animals (30 females and 20 males) of the Genetic Botucatu Group, with a mean age of 85 days and average weight of 2.26 kg were used. The calculation of the intraocular lens was performed using Holladay IOL Consultant ®. The formulas used for the calculation were: Holladay II, Holladay I, Hoffer Q and SRK-T which estimated a mean dioptric power lenses about 48.5 D, 50.27 D, 59.67 D and 49.24 D, respectively. The SRK-T was statistically similar to the Holladay II and Holladay I, while the others were different from each other. Ocular biometric parameters evaluated, as the lens power calculated by the same formula showed no significant differences in relation to gender and laterality
64

Avaliação ultrassonográfica do bulbo ocular em cães submetidos à facectomia por facoemulsificação com ou sem implante de lente intraocular

Pavan, Priscila Teodoro [UNESP] 29 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-29Bitstream added on 2014-06-13T19:30:17Z : No. of bitstreams: 1 pavan_pt_me_botfmvz.pdf: 3799267 bytes, checksum: 720cd0e9fdd18a21ac4ccee753679f56 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O exame ultrassonográfico tem sido utilizado para diagnóstico das doenças oftálmicas humanas desde 1956, já em Medicina Veterinária o seu uso foi somente descrito em 1968; ainda tem sido muito pouco empregado para auxílio no pósoperatório de catarata, onde possui grande importância no diagnóstico de alterações decorrentes da facectomia. O presente trabalho teve por objetivo descrever e comparar as alterações ultrassonográficas encontradas em bulbos oculares de cães submetidos à facectomia por facoemulsificação, com ou sem implante de lente intraocular (LIO), no intuito de auxiliar no diagnóstico de possíveis alterações decorrentes do procedimento cirúrgico e do implante da LIO, bem como sua correspondência com alterações clínicas. Foram utilizados 19 cães machos e fêmeas portadores de catarata já operados, de várias raças e idades, saudáveis, não diabéticos e submetidos à facectomia por facoemulsificação, resultando em 21 bulbos oculares avaliados. Os animais inicialmente foram submetidos a exame oftálmico completo, em ambiente de baixa luminosidade, e em seguida ao exame ultrassonográfico. Foram constituídos três grupos: um de 11 bulbos oculares, CA (cães afácicos), outro de 05 bulbos oculares PP (cães pseudofácicos com implante de duas LIOs em piggyback) e outro PL de 05 bulbos oculares com implante de uma LIO veterinária de 41 D. O exame ultrassonográfico foi realizado sob administração tópica de colírio anestésico oftálmico1, com transdutor linear multifrequencial de 6 a 10 MHz pelas técnicas transpalpebral e corneal. Clinicamente, foram observadas diferentes alterações, dentre elas: luxação da LIO, descolamento de retina, hialose asteróide e degeneração vítrea que foram, posteriormente, confirmadas e classificadas pelo exame ultrassonográfico. Os grupos não mostraram... / The ultrasound has been used for diagnosis of human ophthalmic disease since 1956, veterinary medicine in their use was only described in 1968. The present study aims to describe and compare the ultrasonographic alterations encountered in dogs which underwent facectomy through facoemulsification with or without intraocular lens implant (IOL), in an attempt to assist the diagnosis of possible alterations due to the surgical procedure and IOL implantation, as well as their relation to corresponding clinical signs. The study group was composed by 19 male and female healthy, non-diabetic dogs of various breeds and ages, which had already had surgery for cataract, adding up to the evaluation of 21 ocular bulbs. The animals were initially submitted to complete ophthalmological exams, in a dim environment which preceded the sonogram. Subsequently, the subjects were divided into three distinct groups: Aphakic dogs (CA), pseudophakic dogs implanted with two piggyback IOLs (PP) and dogs implanted with a 41D veterinary IOL (PL), which consisted of 11, 05 and 5 ocular bulbs, respectively. The ultrasound was carried under the topic administration of an anesthetic eye drop1, with a multi frequency linear transducer of 6 to 10 MHz through the transpalpebral and transcorneal technique. The clinical alterations observed were luxation of the IOL, retinal dislocation, asteroid hyalosis, and vitreous degeneration. No statistic difference in the descriptive measures of the variables regarding the ocular axis and the anterior chamber was found, however, when comparing measurements of the cilliar body and the vitreal chamber, the PP group... (Complete abstract click electronic access below)
65

Avaliação ultrassonográfica do bulbo ocular em cães submetidos à facectomia por facoemulsificação com ou sem implante de lente intraocular /

Pavan, Priscila Teodoro. January 2011 (has links)
Orientador: José Joaquim Titton Ranzani / Banca: Maria Jaqueline Mamprim / Banca: Geórgia Nadalini Rodrigues / Resumo: O exame ultrassonográfico tem sido utilizado para diagnóstico das doenças oftálmicas humanas desde 1956, já em Medicina Veterinária o seu uso foi somente descrito em 1968; ainda tem sido muito pouco empregado para auxílio no pósoperatório de catarata, onde possui grande importância no diagnóstico de alterações decorrentes da facectomia. O presente trabalho teve por objetivo descrever e comparar as alterações ultrassonográficas encontradas em bulbos oculares de cães submetidos à facectomia por facoemulsificação, com ou sem implante de lente intraocular (LIO), no intuito de auxiliar no diagnóstico de possíveis alterações decorrentes do procedimento cirúrgico e do implante da LIO, bem como sua correspondência com alterações clínicas. Foram utilizados 19 cães machos e fêmeas portadores de catarata já operados, de várias raças e idades, saudáveis, não diabéticos e submetidos à facectomia por facoemulsificação, resultando em 21 bulbos oculares avaliados. Os animais inicialmente foram submetidos a exame oftálmico completo, em ambiente de baixa luminosidade, e em seguida ao exame ultrassonográfico. Foram constituídos três grupos: um de 11 bulbos oculares, CA (cães afácicos), outro de 05 bulbos oculares PP (cães pseudofácicos com implante de duas LIOs em piggyback) e outro PL de 05 bulbos oculares com implante de uma LIO veterinária de 41 D. O exame ultrassonográfico foi realizado sob administração tópica de colírio anestésico oftálmico1, com transdutor linear multifrequencial de 6 a 10 MHz pelas técnicas transpalpebral e corneal. Clinicamente, foram observadas diferentes alterações, dentre elas: luxação da LIO, descolamento de retina, hialose asteróide e degeneração vítrea que foram, posteriormente, confirmadas e classificadas pelo exame ultrassonográfico. Os grupos não mostraram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The ultrasound has been used for diagnosis of human ophthalmic disease since 1956, veterinary medicine in their use was only described in 1968. The present study aims to describe and compare the ultrasonographic alterations encountered in dogs which underwent facectomy through facoemulsification with or without intraocular lens implant (IOL), in an attempt to assist the diagnosis of possible alterations due to the surgical procedure and IOL implantation, as well as their relation to corresponding clinical signs. The study group was composed by 19 male and female healthy, non-diabetic dogs of various breeds and ages, which had already had surgery for cataract, adding up to the evaluation of 21 ocular bulbs. The animals were initially submitted to complete ophthalmological exams, in a dim environment which preceded the sonogram. Subsequently, the subjects were divided into three distinct groups: Aphakic dogs (CA), pseudophakic dogs implanted with two piggyback IOLs (PP) and dogs implanted with a 41D veterinary IOL (PL), which consisted of 11, 05 and 5 ocular bulbs, respectively. The ultrasound was carried under the topic administration of an anesthetic eye drop1, with a multi frequency linear transducer of 6 to 10 MHz through the transpalpebral and transcorneal technique. The clinical alterations observed were luxation of the IOL, retinal dislocation, asteroid hyalosis, and vitreous degeneration. No statistic difference in the descriptive measures of the variables regarding the ocular axis and the anterior chamber was found, however, when comparing measurements of the cilliar body and the vitreal chamber, the PP group... (Complete abstract click electronic access below) / Mestre
66

Pressão intra-ocular, condições endoteliais e prostaglandina E2 no humor aquoso de cães com catarata senil madura ou hipermatura /

Renzo, Roberta. January 2012 (has links)
Orientador: José Luiz Laus / Banca: Adriana Morales / Banca: Alexandre Lima de Andrade / Resumo: Estudaram-se a pressão intraocular, a densidade e a hexagonalidade de células endoteliais, níveis de Prostaglandina E2 e sua correlação com catarata senil madura (n=8) ou hipermatura (n=8). Adicionalmente, foram utilizados valores de Prostaglandina E2 do humor aquoso de cães oftalmologicamente saudáveis (n=7). Para avaliação da pressão intraocular empregou-se tonometria digital de aplanação. A avaliação da densidade e da hexagonalidade das células endoteliais foi realizada por meio de microscopia especular de não contato. Sob anestesia geral, 0,2mL de humor aquoso foram colhidos por meio de paracentese da câmara anterior. As amostras de aquoso foram congeladas e armazenadas à -80 oC para mensuração da concentração de PGE2, por imunoensaio enzimático competitivo. Os valores foram comparados estatisticamente, empregando-se análise de variância de via única, e o teste de múltiplas comparações de Bonferroni. Teste t não pareado foi utilizado para se avaliar os dados obtidos por microscopia especular. Possíveis correlações entre os resultados foram comparadas aplicando-se o teste de Person. Adotou-se nível de significância de p<0,05. Em ambos os grupos observou-se diminuição significativa da pressão intraocular (PIO), entretanto não houve diferença entre eles (p = 0,90). As médias dos valores de densidade celular (CD) e de hexagonalidade (HEX) foram 2253,363 cell/mm² e 59,03% para GSM e 2058,325 cell/mm² e 63,75% para GSH, respectivamente. Entretanto não houve diferença significativa entre ambos, tanto para CD (p=0,201), quanto para HEX (p=0,61). Observou-se incremento nos valores de PGE2 nos grupos com catarata em relação aos cães oftalmologicamente saudáveis (p<0,001), entretanto, não houve diferença significativa entre os grupos com catarata... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Intraocular pressure, endothelial cell density and hexagonality, and aqueous humor prostaglandin E2 (PGE2) were studied and correlated in dogs with mature (n=8) and hypermature (n=8) senil cataratcs. In addition, aqueous humor PGE2 values of ophthalmic healthy dogs (n=7) were used. Non contact specular microscopy was used to evaluate density and hexagonality of endothelial cells. 0.2mL of aqueous humor was collected by means of anterior chamber paracentesis. Aqueous humor samples were frozen at -80 oC and concentration of PGE2 were quantified by means of competitive enzyme immunoassay. PGE2 values were statistically compared with one way analysis of variance and Bonferroni's multi comparison test. Specular microscopy data were assessed by means of unparied T test. Person's test was used in order to assess possible correlations among data. Significance was set at value of P < 0.05. Values of endothelial cell density and hexagonality did not change significantly between groups (P = 0.61). PGE2 values were significantly higher in dogs with cataract, when compared with ophthalmic healthy dogs (P < 0.001), however, this parameter did not change significantly between mature and hypermature groups (P > 0.05). Is it possible tosay that cataract patients in stages of maturity or hipermaturity develop uveitis... (Complete abstract click electronic access below) / Mestre
67

Mensurações do bulbo ocular e cálculo do poder dióptrico de lentes intraoculares em coelhos (Oryctolagus cuniculus), LINNAEUS, 1758) /

Valinhos, Mayana Andréa Rodrigues. January 2011 (has links)
Orientador: José Joaquim Titton Ranzani / Coorientador: Antonio Carlos Lotelli Rodrigues / Banca: Cláudia Valéria Seullner Brandão / Banca: Luciana Albuquerque Lima Mobricci / Resumo: O trabalho teve por objetivos determinar as dimensões oculares de coelhos, empregando ultrassonografia modo-A e ceratometria, a fim de utilizá-las como subsídios para calcular o poder dióptrico de lentes intraoculares, assim como, avaliar se existe diferença entre as mensurações oculares de machos e fêmeas, bem como entre olho esquerdo e olho direito em coelhos. Foram utilizados 58 animais do Grupo Genético Botucatu, divididos entre 30 fêmeas e 28 machos, com idade média de 85,8 ± 8,29 dias e peso médio de 2,3 ± 0,46 kg. O cálculo da lente intraocular foi realizado através do software Holladay IOL Consultant®. As fórmulas empregadas para o cálculo foram: Holladay II, Holladay I, Hoffer Q e SRK-T que calcularam um poder dióptrico médio para as lentes de 48,5 D; 50,27 D; 59,67 D e 49,24 D, respectivamente. A fórmula SRK-T mostrou-se estatisticamente semelhante às fórmulas Holladay II e Holladay I, enquanto as demais se mostraram diferentes entre si. Os parâmetros biométricos oculares avaliados, assim como o poder dióptrico calculado por uma mesma fórmula não apresentaram diferenças significativas com relação ao sexo e a lateralidade / Abstract: The present study aimed to determine the dimensions of the rabbits eyes using A-mode ultrasound and keratometry, in order to use them as data for calculating the dioptric power of intraocular lenses, as well as assess whether there are differences of ocular measurements between males and females and between the left eye and right eye in rabbits. Fifty-eight animals (30 females and 20 males) of the Genetic Botucatu Group, with a mean age of 85 days and average weight of 2.26 kg were used. The calculation of the intraocular lens was performed using Holladay IOL Consultant ®. The formulas used for the calculation were: Holladay II, Holladay I, Hoffer Q and SRK-T which estimated a mean dioptric power lenses about 48.5 D, 50.27 D, 59.67 D and 49.24 D, respectively. The SRK-T was statistically similar to the Holladay II and Holladay I, while the others were different from each other. Ocular biometric parameters evaluated, as the lens power calculated by the same formula showed no significant differences in relation to gender and laterality / Mestre
68

Estudo clínico da facoemulsificação em cães, com e sem implante de lente intra-ocular em piggyback /

Rodrigues, Georgia Nadalini. January 2005 (has links)
Orientador: José Joaquim Titton Ranzani / Resumo: O objetivo do presente estudo foi avaliar o comportamento do olho canino após a cirurgia para extração de catarata, com e sem implante de lente intra-ocular (LIO) em piggyback, frente a pressão intra-ocular, espessura e curvatura corneanas, densidade e área das células do endotélio da córnea. Empregaram-se, 25 animais da espécie canina de sexo, raça e idades variadas, portadores de catarata, subdivididos em 4 grupos designados por G1 (cães portadores de catarata imatura, com implante de LIO), G2 (cães portadores de catarata madura, com implante de LIO), G3 (cães portadores de catarata imatura, sem implante de LIO) e G4 (cães portadores de catarata madura, sem implante de LIO). A técnica cirúrgica foi a facoemulsificação bimanual. As avaliações da pressão intra-ocular, curvatura e espessura da córnea, foram aferidas antes do procedimento cirúrgico (0) enquanto que, as avaliações das densidade e área das células do endotélio corneano foram realizadas antes do procedimento cirúrgico (0) e nos tempos 7, 28 e 60 dias após o procedimento cirúrgico. A estatística utilizada foi a Análise de Perfil, seguida do método de Tukey para comparações múltiplas, com nível de significância de 5%. Os resultados não demonstraram diferença significativa entre os quatro grupos analisados, no entanto, houve diferença na comparação entre os olhos operados e os contra-laterais. A avaliação qualitativa realizada durante o pós-operatório demonstrou uma maior reação inflamatória e um maior índice de complicações entre os animais dos grupos 1 e 2. Concluí-se que não houve diferença entre os grupos, no entanto, demonstrou-se diferença entre o olho operado e não-operado. Entretanto, o pós-operatório dos animais dos grupos 1 e 2 revelou-se mais complicado, expressando uma reação inflamatória mais exacerbada e um maior índice de complicações. / Abstract: The purpose of this study was to investigate the effects in intraocular pressure, central corneal thickness, corneal curvature, cellular density and area of corneal endothelium after surgery for cataract extraction with and without intraocular lens (IOL) implantation using piggyback technique in eyes of dogs. A total of 25 dogs were divided into 4 groups: Group 1 (dogs with immature cataract and with IOL implantation), Group 2 (dogs with mature cataract and with IOL implantation), Group 3 (dogs with immature cataract and without IOL implantation) and Group 4 (dogs with mature cataract and without IOL implantation). The surgical technique performed was bimanual phacoemulsification. Intraocular pressure, central corneal thickness and corneal curvature were measured before surgery (0) and at 3, 7, 14, 21, 28, 60 days of postoperative. Cellular density and area of corneal endothelium were measured before surgery and at 7, 28, 60 days of postoperative. Statistical analysis was performed using variance analysis (profile) and Tukey test for multiple comparison with significance at p<0.05. The 4 groups did not differ significantly with respect to parameters evaluated. There was, however, a significant difference between the two eyes (operated and nonoperated). However, the dogs of groups 1 and 2 had more complicate postoperative with more severe ocular inflammation and number of complications. / Doutor
69

Análise de qualidade óptica e performance visual em olhos implantados com lentes intraoculares asféricas neutras / Implantation of an aspherical intraocular lens

Marcony Rodrigues de Santhiago 05 October 2012 (has links)
Objetivo: Determinar se o implante de uma determinada lente intraocular asférica resulta em redução das aberrações oculares e melhora da qualidade ótica e sensibilidade ao contraste sem que ocorra redução critica da profundidade de foco. Desenho: Estudo prospectivo, duplo-cego, randomizado. Métodos: Este estudo que incluiu 25 pacientes com catarata bilateral, uma LIO asférica foi implantada em um olho e uma LIO esférica no olho contralateral. Aberrações de maior ordem e parâmetros de qualidade ótica foram obtidos através de aberrômetro de retinoscopia dinâmica, 1 e 3 meses apos a cirurgia. Foi também medido a acuidade visual com e sem correção e a sensibilidade ao contraste. Acuidade visual para perto e distancia intermediaria foi obtida como forma de medida da profundidade de foco. Resultados: Não houve diferença estatisticamente significativa entre os grupos para acuidade visual corrigida e não corrigida 1 e 3 meses apos a cirurgia. Houve diferença estatisticamente significativa entre os grupos quanto a sensibilidade ao contraste sob condições fotópticas na frequência espacial de 12 ciclos por grau e sob condições mesópicas em todas as frequências espaciais estudadas. O grupo com a LIO Akreos AO obteve menores valores de aberrações de maior ordem totais e de aberração esférica com pupilas de 5 e 6 mm e melhores valores de qualidade ótica comparado ao grupo com LIO Akreos Fit (p <0.05). Não houve diferença significativa entre os grupos quando se investigou visão de perto e intermediaria corrigido para longe. Conclusões: A LIO asférica Akreos AO induziu menos aberrações de maior ordem além de produzir melhores parâmetros de qualidade ótica com melhores resultados de sensibilidade ao contraste em condições mesópicas sem redução critica de profundidade de foco quando comparado a LIO esférica Akreos Fit. / PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved optical quality and contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil and optical quality parameters were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distancecorrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at 1 and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils and better optical quality parameters compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity under mesopic conditions and optical quality parameters were better with the Akreos AO with similar results of depth of focus.
70

Lente intraocular suplementar Sulcoflex® Multifocal : análise dos resultados e complicações / Sulcoflex® Multifocal intraocular lens : analysis of clinical results and complications

Bisneto, Otavio Siqueira, 1974- 23 August 2018 (has links)
Orientador: Carlos Eduardo Leite Arieta / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-23T07:26:52Z (GMT). No. of bitstreams: 1 Bisneto_OtavioSiqueira_D.pdf: 1957765 bytes, checksum: 2b131f1ff863d58643b8b214c93cb0cf (MD5) Previous issue date: 2013 / Resumo: Objetivo: avaliar os resultados clínicos e possíveis complicações do implante da lente intraocular (LIO) Sulcoflex® Multifocal. Material e Método: realizou-se estudo tipo série de casos de indivíduos submetidos ao implante bilateral da LIO Sulcoflex® Multifocal no Hospital de Olhos do Paraná (Curitiba - Brasil). Foram incluídos indivíduos previamente operados de catarata, submetidos ao implante bilateral da LIO Sulcoflex® Multifocal, no período de julho de 2010 a janeiro de 2012, sendo os principais critérios de inclusão presença de LIO monofocal não acomodativa implantada no saco capsular de ambos os olhos e acuidade visual corrigida ou não de 20/25 ou melhor em ambos os olhos e os principais critérios de exclusão presença de doença ocular associada e refração cilíndrica maior que 0,75 D negativa ou esférica maior que 3 D positivas ou negativas. Foram estudadas as seguintes variáveis: acuidade visual para longe e para perto com e sem correção óptica; grau de refração esféro-cilíndrica; pressão intraocular; contagem de células endoteliais; aberrações ópticas de alta ordem; sensibilidade ao contraste e complicações intra e pós-operatórias. Todas as cirurgias foram realizadas pelo mesmo cirurgião, sob anestesia tópica, com implante da LIO por incisão de 2,75mm, objetivando se a emetropia. Resultados: foram avaliados 16 olhos de 8 indivíduos. A idade média foi de 63.87±7,1 anos variando de 55 a 79 anos. O tempo médio de seguimento foi de 11,37 +- 1,4 meses variando de 10 a 14 meses. Houve piora de 1 linha da acuidade visual para longe sem correção óptica em 7 olhos (43,7%), e melhora da acuidade visual de perto com todos os olhos apresentando J2 ou melhor sem correção óptica. Conclusão: após o implante da LIO Sulcoflex® Multifocal houve melhora da acuidade visual de perto sem correção óptica, e diminuição da acuidade visual de longe com e sem correção óptica, e da sensibilidade ao contraste em 2 das 5 frequências espaciais estudadas. A abertura invertida (face anterior voltada posteriormente) de uma lente no momento do implante ocasionou perda significativa de células endoteliais neste olho / Abstract: Purpose: to evaluate the clinical results and possible complications of the Sulcoflex® Multifocal intraocular lens implantation. Methods: It was conducted a case series study of patients undergoing IOL Sulcoflex® Multifocal bilateral implantation at Paraná Eye Hospital (Curitiba - Brazil). It were included patients previously operated for cataract, underwent bilateral implantation of IOL Sulcoflex® Multifocal, from July 2010 to January 2012, being the main inclusion criteria, presence of monofocal no accommodative IOL implanted in capsular bag in both eyes and best corrected or not visual acuity 20/25 or better in both eyes; the main exclusion criterias were presence of eye disease, cylindrical refraction greater than -0.75 diopters or greater than 3 positive or negative spherical diopters. It were studied the following variables: visual acuity for near and distance vision with and without optical correction; degree of sphero-cylindrical refraction, intraocular pressure, endothelial cell count, high-order aberrations, contrast sensitivity and intra and postoperative complications. All surgeries were performed by the same surgeon, under topical anesthesia with IOL implant incision by 2.75 mm, with the target of emmetropia. Results: It was evaluated 16 eyes of 8 persons. The mean age was 63,87 +- 7,1 years, ranging from 55 to 79 years. The mean follow up was 11,37 +- 1,4 months, ranging from 10 to 14 months. It was observed decreased of 1 line in distance visual acuity without correction in 7 eyes (43,7%), and improvement of near visual acuity, with all eyes J2 or better without correction. Conclusion: after Sulcoflex® Multifocal IOL implantation, the near vision without correction was improved, the far vision with and without correction was decreased, and contrast sensitivity was decreased in 2 of 5 spatial frequencies studieds. The reverse opening (anterior facing back) of one IOL at the time of implantation caused a significant loss of endothelial cells in this eye / Doutorado / Oftalmologia / Doutor em Ciências Médicas

Page generated in 0.0602 seconds