TONOMETRIA E ECOBIOMETRIA OCULAR EM TUCANO-TOCO (Ramphastos toco) E TUCANO-DE-BICO-VERDE (Ramphastos dicolorus) / OCULAR TONOMETRY AND SONOGRAPHIC BIOMETRY IN TOCO TOUCAN (Ramphastos toco) AND RED-BREASTED TOUCAN (Ramphastos dicolorus)

Marchan, Pedro Rafael Apulcro Correa 18 December 2015 (has links)
The eyesight of birds is essential for their survival in a free environment; tiny alteration in this organ may cause loss of vision, consequently the difficulty or even the impossibility to hunt, move or protect themselves from predators; due to these particularities, the objective of this paper was to know the normal rate of intra-ocular pressure (IOP) and to identify the ocular anatomy through sonographic biometry in B-scan through transpalpebral way, so the ophthalmic examination can be complete and reliable. It was valued the IOP of 15 Toco Toucans (Ramphatos toco) and 15 Red-breasted Toucan (Ramphastos dicolorus) through applanation tonometry, using a Tono-Pen VET® tonometer and executed sonographic biometry ocular in 5 Toucans Toco and in 5 Red-breasted Toucan. The IOP from Toco Toucans, reliable in 95% got the media between 13,79 mmHg to17,61 mmHg, while the Red-breasted Toucan got the IOP between 12,05 mmHg and 16,81 mmHg. The ocular ultrasound eye was efficient as it could identify the previous segment, the lens, the posterior segment, positioning of the retina, Pecten and retrobulbar space. The Toco Toucans sonographic biometry obtained the bulbar average axial length of 1,66 cm, axial shaft of anterior segment 0,25 cm, shaft axial lens 0,35 cm axial shaft of posterior segment 1,05 cm, transverse shaft of the posterior segment 2,20 cm, transverse shaft of the lens 1,21 cm, and in Red-breasted Toucan the bulbar average axial length of 1,29 cm, axial shaft of anterior segment 0,10 cm, axial shaft lens 0,40 cm axial shaft of posterior segment 0,79 cm, shaft transverse of the posterior segment 1,39 cm, shaft transverse of the lens 0,99 cm. It follows that it is possible to measure IOP by tonometry with Tono-pen VET® tonometer and ocular sonographic biometry the B-scan transpalpebral, route is feasible for these species. / A visão das aves é fundamental para a sua sobrevivência em vida livre, pequenas alterações neste órgão, podem levar a perda da acuidade visual, consequentemente dificuldade ou mesmo impossibilidade em caçar, se locomover ou se defender de predadores. Devido a estas particularidades, o objetivo deste trabalho foi o de conhecer o valor normal da pressão intraocular (PIO) e identificar a anatomia ocular por meio da ecobiometria em modo B pela via transpalpebral, tornando o exame oftálmico mais completo e fidedigno. Foi avaliada a PIO de 15 Tucanos-toco (Ramphastos toco) e de 15 Tucanos-de-bico-verde (Ramphastos dicolorus) por meio da tonometria de aplanação, usando o tonômetro Tono-Pen VET®. Foi realizado ecobiometria ocular em 5 Tucanos-toco e 5 Tucanos-de-bico-verde. A PIO dos Tucanos-toco com 95% de confiança teve uma média entre 13,79 mmHg e 17,61 mmHg, já os Tucanos-de-bico-verde tiveram a PIO entre 12,05 mmHg e 16,81 mmHg. A ecografia ocular se mostrou eficiente pois foram identificados o segmento anterior, a lente, o segmento posterior, o posicionamento da retina, o pécten e o espaço retrobulbar. Na ecobiometria foram obtidos nos Tucanos-toco média do eixo axial bulbar de 1,66 cm, eixo axial do segmento anterior 0,25 cm, eixo axial do segmento posterior 1,05 cm, eixo transversal do segmento posterior 2,20 cm, eixo axial da lente 0,35 cm e eixo transversal da lente 1,21 cm, e nos Tucanos-de-bico-verde a média do eixo axial bulbar de 1,29 cm, eixo axial do segmento anterior 0,10 cm, eixo axial do segmento posterior 0,79 cm, eixo transversal do segmento posterior 1,39 cm, eixo axial da lente 0,40 cm e eixo transversal da lente 0,99 cm. Conclui-se que é possível mensurar a PIO por meio da tonometria de aplanação com o tonômetro Tono-pen VET® e que a ecobiometria ocular, em modo B pela via transpalpebral é viável para estas espécies.
102

PATOLOGIA OCULAR EM ANIMAIS DOMÉSTICOS / OCULAR PATHOLOGY IN DOMESTIC ANIMALS

Martins, Tessie Beck 19 January 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This doctoral thesis involved the study of ocular and periocular diseases affecting domestic animals, and included one manuscript about lesions of surgical pathology and one manuscript about hyphema in dogs and cats submitted to necropsy. In the first part, 33,075 reports of hystopathological exams performed in a veterinary pathology diagnostic laboratory in the Central Region of the State of Rio Grande do Sul, Brazil, over 50 years. From the total amount, 540 (1.6%) concerned ocular and periocular lesions. For various reasons ninety specimens were excluded from the study, 450 remaining. More than half of all cases consisted of samples from dogs (53.5%), followed by cattle (28.2%), cats (11.1%), horses (5.1%) sheep (1.3%), rabbits (0.4%), and pig (0.2%). The eyelids were the most prevalent (248/450) site of lesions in each of the species studied, followed by third eyelid (73/450), and conjunctiva (27/450). In dogs lesions in sebaceous glands were the most common findings (75/241), followed by melanocytic tumors and nonspecific conjunctivitis. In cattle, anatomical sites affected by ocular and periocular lesions, in decreasing order of frequency, were eyelid, cornea and third eyelid. Squamous cell carcinoma (SCC) alone accounted for 80.3% of all lesions diagnosed in cattle. Neoplasia accounted for most of the lesions diagnosed in cats (39/50 cases); all of these were malignant, and SCC, hemangiosarcoma and fibrosarcoma were the most common types diagnosed. In horses, 19 out of 23 submissions were neoplasms and most were sarcoid (8/23) and SCC (8/23). In sheep, all samples represented SCC of the eyelids (5) and third eyelid (1). For the second manuscript, cases of hyphema in dogs and cats submitted to necropsy were examined. Twenty cases, 14 dogs and six cats of several ages and breeds and of both sexes were included in the study. Hyphema presented as a unilateral (14 cases out of 20) or bilateral (6/20) disorder in dogs and cats and extension of hemorrhage varied from minimal to diffuse. Hyphema was secondary to systemic disease (15/20) or occurred as a primary ocular lesion (5/20) in four dogs and one cat. Primary hyphema was always unilateral. In four of these cases, the cause of hyphema was trauma and remaining case was caused by phacoclastic uveitis in a dog with bilateral hypermature cataract. Various causes of bleeding disorders were found related to secondary hyphema: in decreasing order of frequency, they included vasculitis (8/15), systemic hypertension (5/15), and acquired coagulopathies (2/15). / Esta tese envolveu o estudo de doenças oculares e perioculares de animais domésticos, e incluiu um artigo sobre lesões de patologia cirúrgica e um artigo sobre hifema em cães e gatos submetidos à necropsia. Para o primeiro trabalho, foram examinados 33.075 laudos de exames histopatológicos realizados num laboratório de diagnóstico de patologia veterinária na Região Central do Rio Grande do Sul durante 50 anos. Destes, 540 (1,6%) eram de lesões oculares e perioculares. Por várias razões, 90 espécimes foram excluídos do estudo, restando 450. Mais da metade dos casos correspondiam a espécimes de cães (53,5%), seguidos por bovinos (28,2%), gatos (11,1%), cavalos (5,1%), ovelhas (1,3%), coelhos (0,4%), e porco (0,2%). As pálpebras foram o local mais prevalente (248/450) de ocorrência das lesões em cada uma das espécies, seguidas da terceira pálpebra (73/450) e conjuntiva (27/450). Em cães, as lesões nas glândulas sebáceas consistiram nos achados mais comuns, seguidos dos tumores melanocíticos e de conjuntivites inespecíficas. Em bovinos, os locais anatômicos afetados por lesões perioculares e oculares, em ordem decrescente de frequência, foram pálpebra, córnea e terceira pálpebra. Somente o carcinoma de células escamosas (CCE) perfez 80,3% de todas as lesões diagnosticadas em bovinos. Em gatos, a maioria (39/50 casos) das lesões diagnosticadas era de neoplasia maligna, e CCE hemangiossarcoma e fibrosarcoma foram os diagnósticos mais frequentes. Em equinos 19 de 23 submissões eram neoplasmas e os mais comuns foram sarcoide (8/23) e CCE (8/23). Em ovinos, todas as amostras correspondiam a casos de CCE de pálpebra (5/6) ou terceira pálpebra (1/6). Para o segundo trabalho, casos de hifema em cães e gatos submetidos à necropsia foram examinados. Vintes casos, 14 cães e seis gatos de várias idades e raças e de ambos os sexos foram incluídos no estudo. O hifema teve uma apresentação unilateral (14 casos dos 20) ou bilateral (6/20), e a extensão da hemorragia variou de mínima a difusa. O hifema era secundário à doença sistêmica (15/20) ou ocorreu como lesão ocular primária em cinco dos 20 casos (quatro cães e um gato). O hifema primário foi sempre unilateral; a causa foi traumatismo em quatro desses casos, e o caso restante foi causado por uveíte facoclástica em um cão com catarata hipermadura bilateral. Várias causas de distúrbios hemorrágicos foram encontradas em relação ao hifema secundário: em ordem decrescente de frequência foram: vasculite (8/15), hipertensão sistêmica (5/15) e coagulopatias adquiridas (2/15).
103

Uso do tonômetro de aplanação portátil Kowa HA-2 na mensuração da pressão intraocular em gatos / Use of portable applanation tonometer Kowa HA-2 in the measurement of intraocular pressure in cats

Ricci, Cláudia Lizandra 17 March 2015 (has links)
Made available in DSpace on 2016-01-26T18:55:43Z (GMT). No. of bitstreams: 1 Claudia Lizandra Ricci.pdf: 291013 bytes, checksum: b9dccb042e091da74b7d28825ae3639d (MD5) Previous issue date: 2015-03-17 / The objective of this study was to measurement of the intraocular pressure (IOP) with Kowa HA-2 tonometer in cats analyzing the calibration, the accuracy and the validation of ambulatory clinical use. For calibration the post-mortem study was accomplished in 10 healthy eyes of 5 cats comparing the ocular manometry with the values of the IOP checked with the tonometer. For evaluation of the accuracy an in vivo study was accomplished in 20 healthy eyes of 10 anesthetized cats being compared the ocular manometry with the IOP obtained with the tonometer. For validation of the ambulatory clinical study of the IOP measurement was accomplished in 78 eyes of 39 healthy cats, in 7 eyes with clinical signs of glaucoma and in 20 eyes with clinical signs of uveitis. The correlation coefficient (r²) between the manometer and the tonometer was 0.993 and the equation of lineal regression was y=0.0915x+0.0878 in postmortem study. In the in vivo study the medium values of IOP in the manometry were 15.6±1.1 mmHg and in the tonometry were 15.5±1.2 mmHg, there was no statistics significant difference between the manometry and the tonometry. In the ambulatory clinical study with healthy cats the medium values of IOP with the tonometer were 15.0±1.5 mmHg, in the eyes with clinical signs of glaucoma were 38,4±8,1 mmHg and in the eyes with clinical signs of uveitis were of 10,4±2,0 mmHg. Therefore, there was a satisfactory correlation and accuracy between the IOP values obtained by direct ocular manometry and the tonometer in question. In the ambulatory clinical study the IOP values obtained with the tonometer were compatible for animals with healthy eyes and with clinical signs of glaucoma and uveitis. So, we can conclude that the Kowa HA-2 tonometer can be used in the routine ophthalmic examination, as it is a practical method for IOP measurement in cats. / O objetivo deste estudo foi mensurar a pressão intraocular (PIO) com o uso do tonômetro Kowa HA-2 em gatos, analisando a calibração, a acurácia e a validação do seu uso clínico ambulatorial. Para calibração foi realizado o estudo post-mortem em 10 olhos sadios de 5 gatos comparando a manometria ocular com os valores da PIO aferida com o tonômetro. Para avaliação de sua acurácia foi realizado um estudo in vivo em 20 olhos sadios de 10 gatos anestesiados comparando-se a manometria ocular com a PIO obtida com o tonômetro. Para validação do seu uso clínico ambulatorial foi realizado um estudo da mensuração da PIO em 78 olhos sadios de 39 gatos, em 7 olhos com sinais clínicos de glaucoma e em 20 olhos com sinais clínicos de uveíte. O coeficiente de correlação (r²) entre o manômetro e o tonômetro Kowa HA-2 foi de 0,993 e a equação de regressão linear foi y=0,0915x+0,0878 no estudo postmortem. No estudo in vivo, os valores médios de PIO na manometria foram de 15,6±1,1 mmHg e na tonometria foram de 15,5±1,2 mmHg não havendo diferença estatística significativa entre a manometria e a tonometria. No estudo ambulatorial com os gatos sadios, os valores médios de PIO com o tonômetro Kowa HA-2 foram 15,0±1,5 mmHg, nos olhos com sinais clínicos de glaucoma foram 38,4±8,1 mmHg e nos olhos com sinais clínicos de uveíte foram 10,4±2,0 mmHg. Houve, portanto, correlação e acurácia satisfatória entre os valores de PIO com a manometria e o tonômetro em questão. No estudo ambulatorial os valores de PIO obtidos com o tonômetro foram compatíveis para animais com olhos sadios e com sinais clínicos de glaucoma e uveíte. Desta maneira, podemos concluir que o tonômetro Kowa HA-2 pode ser empregado no exame oftálmico de rotina, pois trata-se de um método prático na aferição da PIO em gatos.
104

Uso do tonômetro de aplanação portátil Kowa HA-2 na mensuração da pressão intraocular em gatos / Use of portable applanation tonometer Kowa HA-2 in the measurement of intraocular pressure in cats

Ricci, Cláudia Lizandra 17 March 2015 (has links)
Made available in DSpace on 2016-07-18T17:53:15Z (GMT). No. of bitstreams: 1 Claudia Lizandra Ricci.pdf: 291013 bytes, checksum: b9dccb042e091da74b7d28825ae3639d (MD5) Previous issue date: 2015-03-17 / The objective of this study was to measurement of the intraocular pressure (IOP) with Kowa HA-2 tonometer in cats analyzing the calibration, the accuracy and the validation of ambulatory clinical use. For calibration the post-mortem study was accomplished in 10 healthy eyes of 5 cats comparing the ocular manometry with the values of the IOP checked with the tonometer. For evaluation of the accuracy an in vivo study was accomplished in 20 healthy eyes of 10 anesthetized cats being compared the ocular manometry with the IOP obtained with the tonometer. For validation of the ambulatory clinical study of the IOP measurement was accomplished in 78 eyes of 39 healthy cats, in 7 eyes with clinical signs of glaucoma and in 20 eyes with clinical signs of uveitis. The correlation coefficient (r²) between the manometer and the tonometer was 0.993 and the equation of lineal regression was y=0.0915x+0.0878 in postmortem study. In the in vivo study the medium values of IOP in the manometry were 15.6±1.1 mmHg and in the tonometry were 15.5±1.2 mmHg, there was no statistics significant difference between the manometry and the tonometry. In the ambulatory clinical study with healthy cats the medium values of IOP with the tonometer were 15.0±1.5 mmHg, in the eyes with clinical signs of glaucoma were 38,4±8,1 mmHg and in the eyes with clinical signs of uveitis were of 10,4±2,0 mmHg. Therefore, there was a satisfactory correlation and accuracy between the IOP values obtained by direct ocular manometry and the tonometer in question. In the ambulatory clinical study the IOP values obtained with the tonometer were compatible for animals with healthy eyes and with clinical signs of glaucoma and uveitis. So, we can conclude that the Kowa HA-2 tonometer can be used in the routine ophthalmic examination, as it is a practical method for IOP measurement in cats. / O objetivo deste estudo foi mensurar a pressão intraocular (PIO) com o uso do tonômetro Kowa HA-2 em gatos, analisando a calibração, a acurácia e a validação do seu uso clínico ambulatorial. Para calibração foi realizado o estudo post-mortem em 10 olhos sadios de 5 gatos comparando a manometria ocular com os valores da PIO aferida com o tonômetro. Para avaliação de sua acurácia foi realizado um estudo in vivo em 20 olhos sadios de 10 gatos anestesiados comparando-se a manometria ocular com a PIO obtida com o tonômetro. Para validação do seu uso clínico ambulatorial foi realizado um estudo da mensuração da PIO em 78 olhos sadios de 39 gatos, em 7 olhos com sinais clínicos de glaucoma e em 20 olhos com sinais clínicos de uveíte. O coeficiente de correlação (r²) entre o manômetro e o tonômetro Kowa HA-2 foi de 0,993 e a equação de regressão linear foi y=0,0915x+0,0878 no estudo postmortem. No estudo in vivo, os valores médios de PIO na manometria foram de 15,6±1,1 mmHg e na tonometria foram de 15,5±1,2 mmHg não havendo diferença estatística significativa entre a manometria e a tonometria. No estudo ambulatorial com os gatos sadios, os valores médios de PIO com o tonômetro Kowa HA-2 foram 15,0±1,5 mmHg, nos olhos com sinais clínicos de glaucoma foram 38,4±8,1 mmHg e nos olhos com sinais clínicos de uveíte foram 10,4±2,0 mmHg. Houve, portanto, correlação e acurácia satisfatória entre os valores de PIO com a manometria e o tonômetro em questão. No estudo ambulatorial os valores de PIO obtidos com o tonômetro foram compatíveis para animais com olhos sadios e com sinais clínicos de glaucoma e uveíte. Desta maneira, podemos concluir que o tonômetro Kowa HA-2 pode ser empregado no exame oftálmico de rotina, pois trata-se de um método prático na aferição da PIO em gatos.
105

Optimización del cálculo de lentes intraoculares en base a la caracterización de la posición anatómica de la lente mediante reflectometría óptica de baja coherencia

Fukumitsu, Hideki 31 March 2023 (has links)
Tesis por compendio de artículos donde se realizó un estudio observacional, prospectivo donde se incluyeron 450 ojos que se han sometido una cirugía de la catarata a los cuales posteriormente se realizaron varias mediciones con un biómetro de reflectometría óptica de baja coherencia. Los objetivos fueron: en primero lugar valorar la consistencia de las medidas anatómicas, posteriormente caracterizar la posición de dos tipos de lentes intraoculares, definir un modelo de predicción y por último optimizar las fórmulas para el cálculo de la lente intraocular teniendo en cuenta el algoritmo de predicción. En conclusión, se ha observado que el biómetro proporciona mediciones anatómicas consistentes en ojos pseudofáquicos implantados con las dos lentes del estudio. Igualmente fue evidente que los cambios en la longitud axial tras la cirugía de cataratas pueden explicar el nivel de error en la predictibilidad refractiva obtenido mediante la fórmula de vergencia SRK-T. Con esto hemos podido definir una fórmula de estimación de la ELP para la fórmula SRK-T. Por último, los cambios en la refracción entre los meses 1 a 6 no están relacionados con la inestabilidad posicional de la LIO ni con los cambios en la longitud axial adicionales.
106

Effect of cataract surgery incision location and intraocular lens type on ocular aberrations.

Pesudovs, Konrad, Dietze, Holger H., Stewart, O., Noble, B.A., Cox, Michael J. January 2005 (has links)
No / To determine whether Hartmann-Shack wavefront sensing detects differences in optical performance in vivo between poly(methyl methacrylate) (PMMA) and foldable acrylic intraocular lenses (IOLs) and between clear corneal and scleral tunnel incisions and whether optical differences are manifested as differences in visual performance. SETTING: Department of Optometry, University of Bradford, West Yorkshire, United Kingdom. METHODS: This study comprised 74 subjects; 17 were phakic with no ocular pathology, 20 had implantation of a Pharmacia 722C PMMA IOL through a scleral tunnel, 21 had implantation of an Alcon AcrySof IOL through a scleral tunnel, and 16 had implantation of an AcrySof IOL through a corneal incision. Visual acuity and contrast sensitivity testing, ocular optical quality measurement using Hartmann-Shack wavefront sensing, and corneal surface measurement with a videokeratoscope were performed in all cases. RESULTS: There were significant differences between groups in the total root-mean-square (RMS) wavefront aberration over a 6.0 mm pupil (F=3.91; degrees of freedom=3,70; P<.05) mediated at the 4th-order RMS, specifically spherical and tetrafoil aberrations. The PMMA-scleral group had the least aberrations and the AcrySof-corneal group the most. For a 3.5 mm diameter pupil, the total higher-order RMS wavefront aberration was not significantly different between the groups (P>.05). There were no differences between groups in corneal shape, visual acuity, or contrast sensitivity. CONCLUSIONS: Implantation of the spherical PMMA IOL led to a slight reduction in total wavefront aberration compared to phakic eyes. AcrySof IOLs induced more aberrations, especially spherical aberration. Corneal-based incisions for IOL implantation compounded this increase. Studies of the optical performance of IOLs in vivo should use wavefront sensing as the main outcome measure rather than visual measures, which are readily confounded by multiple factors.
107

Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

Eom, Youngsub, Ryu, Dongok, Kim, Dae Wook, Yang, Seul Ki, Song, Jong Suk, Kim, Sug-Whan, Kim, Hyo Myung 10 1900 (has links)
Background: To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP). Methods Two thousand samples of corneal parameters with keratometric astigmatism >= 1.0 D were obtained using boot-strap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results. Results The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation. Conclusions The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.
108

Correção da presbiopia pseudofácica através da implantação secundária de diafragma estenopeico no sulco ciliar / Pseudophakic presbyopia correction through secondary implantation of pinhole diaphragm in the ciliary sulcus

Trindade, Claudio Lovaglio Cançado 16 April 2019 (has links)
INTRODUÇÃO: A presbiopia pseudofácica, imposta pela extração do cristalino e implantação de uma lente intraocular monofocal, representa uma relativa limitação da cirurgia de catarata moderna. Diversos métodos para compensação de tal fenômeno já foram descritos. Nesse estudo, avaliamos a eficácia de um implante intraocular estenopeico em promover ampliação da profundidade de foco, e seu impacto no desempenho visual. MÉTODOS: Foram selecionados 10 pacientes hígidos, com boa saúde ocular, previamente submetidos a cirurgia de catarata bilateral com implante de lente intraocular monofocal, os quais apresentavam limitação da acuidade visual para perto. Os pacientes foram submetidos a implantação monocular do diafragma intraocular estenopeico XtraFocus®, no sulco ciliar. As variáveis avaliadas foram acuidade visual, refração subjetiva, sensibilidade ao contraste, amplitude de pseudoacomodação (curva de defocus), estereopsia, campimetria computadorizada, teste de efeito Pulfrich, e avaliação subjetiva do desempenho visual, através da aplicação de questionário. RESULTADOS: Houve significativa melhora da acuidade visual para perto, com 7 pacientes alcançando acuidade visual sem correção para perto de 20/30, no olho operado. Não houve impacto significativo na refração subjetiva, sensibilidade ao contraste e estereopsia. A perimetria computadorizada evidenciou redução de sensibilidade retiniana difusa, no olho operado. A percepção subjetiva do desempenho visual após o tratamento foi favorável, com impacto positivo nas atividades diárias. Não foi observada indução de efeito Pulfrich. CONCLUSÕES: O implante estenopeico estudado foi capaz de promover ampliação da profundidade de foco, com aprimoramento da acuidade visual para perto. O implantação cirúrgica se mostrou segura, sem ocorrência de eventos adversos significativos. Os resultados sugerem que uma maior independência de óculos pode ser alcançada caso a técnica seja aplicada em pacientes portadores de miopia de pequena magnitude. Este achado está em conformidade com trabalhos prévios envolvendo dispositivos estenopeicos. Apesar da limitação à entrada de luz imposta pelo orifício estenopeico, a percepção de luminosidade não é proporcionalmente impactada. Entretanto, em condições de baixa luminosidade, pode haver uma percepção monocular de escuridão / INTRODUCTION: Pseudophakic presbyopia, imposed by crystalline lens extraction and implantation of an artificial monofocal intraocular lens (IOL), represents a relative limitation of modern cataract surgery. Several methods of compensation of this phenomenon have been proposed. In this study, we evaluate the efficacy of a pinhole intraocular implant in promoting depth of focus extension, and its impact in visual performance. METHODS: A selection of 10 healthy patients, with no ocular comorbidity, previously submitted to bilateral cataract surgery and monofocal IOL implantation, presenting with near vision limitation, was carried out. Patients underwent monocular implantation of the XtraFocus® pinhole implant, in the ciliary sulcus. Outcome variables were visual acuity, subjective refraction, contrast sensitivity, amplitude of pseudoaccommodation (defocus curve), stereoacuity, automated perimetry, Pulfrich effect testing and subjective visual performance evaluation with a questionnaire. RESULTS: A significant improvement in near visual acuity was observed, with 7 patients reaching 20/30 uncorrected near visual acuity, in the operated eye. There was no significant impact in subjective refraction, contrast sensitivity and stereoacuity. Automated perimetry revealed a reduction of overall retinal sensitivity, in the operated eye. Subjective assessment of visual performance was favourable, with positive impact in daily activities. Induction of Pulfrich effect was not observed. CONCLUSIONS: The pinhole implant evaluated in this study was able to provide depth of focus extension, and enhance near visual acuity. Surgical implantation was safe, with no occurrence of significant adverse events. Results suggest that a greater level of spectacle independence may be achieved if this approach is combined with low levels of myopia. This finding is in accordance with other studies involving small aperture optics. In spite of the reduction of light entrance caused by the pinhole implant, the overall brightness sensation is not proportionally impaired. However, under low light conditions, a monocular darkening perception can occur
109

Revisão interna de Simmons: análise de seus resultados clínicos e complicações / Internal revision of Simmons: analysis of his clinical results and complications

Pinheiro, Renato Klingelfus 02 February 2007 (has links)
INTRODUÇÃO: É importante estudar a efetividade da trabeculectomia e estratégias para manter sua ação ao longo do tempo. Para melhorarmos o prognóstico das revisões cirúrgicas é imprescindível entendermos melhor a estrutura da bolha filtrante e suas possíveis causas de falência. Formas alternativas para se restabelecer a drenagem e o funcionamento da trabeculectomia não funcionante foram desenvolvidas, entre elas a Revisão Interna de Simmons. OBJETIVOS: Avaliar os efeitos da Revisão Interna de Simmons sobre a PIO; sobre o aspecto biomicroscópico da bolha no pós-operatório e sua correlação com achados biométricos obtidos pela biomicroscopia ultra-sônica. CASUÍSTICA E MÉTODOS: Foram incluídos e estudados de forma prospectiva por 6 meses, 29 pacientes portadores de glaucoma primário, submetidos a trabeculectomia prévia,há pelo menos três meses, que apresentavam PIO acima do esperado para o controle do glaucoma, apesar de medicação hipotensora utilizada. Foram fatores de inclusão a conjuntiva livre e o óstio interno da trabeculectomia patente à gonioscopia. O critério de sucesso foi: abaixamento da PIO, igual ou maior que 30% da PIO em relação à PIO pré-operatória e/ou pressão final menor ou igual a 15mmHg, com ou sem medicação antiglaucomatosa associada. RESULTADOS: Houve uma queda estatisticamente significante da PIO e do número de medicações utilizadas após a cirurgia. A PIO média antes da operação era de 23,72 ± 4,10 mmHg e ao término do estudo, de 15,04 ± 4,00 mmHg (p=0,000016). A média das pressões da curva tonométrica antes da cirurgia era de 22,36 ± 3,91mmHg, caindo para 15,01 ± 3,95mmHg no PO180d (p=0,0000001). Antes da cirurgia, a média do número de medicações usadas era de 2,1 ± 0,77 e ao término do estudo, 1,22 ± 1,01 (p=0,001117). Houve um aumento do tamanho da bolha filtrante, avaliado pela biomicroscopia. As bolhas apresentaram altura média de 0,28 ± 0,65 e terminaram o estudo com altura de 0,78 ± 0,85 (p=0,000016). Não houve diferença na altura da bolha, medida pela biomicroscopia ultra-sônica após a cirurgia. A pressão intra-ocular apresentou relação inversamente proporcional à dimensão da bolha filtrante, com significância estatística. As complicações mais encontradas foram: descolamento da membrana de Descemet, no local da incisão principal em 5 doentes (17,2%), abertura inadvertida da conjuntiva em 4 (13,8%), e descolamento de coróide, em 3 (10,3%). CONCLUSÕES: A Revisão Interna de Simmons proporcionou diminuição de 30% da PIO em 52% dos pacientes e redução do número de medicações antiglaucomatosas associadas, quando utilizadas. As bolhas se mostraram-se estatisticamente maiores após o procedimento. Houve uma correlação perfeita entre a classificação da altura da bolha entre a medida biomicroscópica baseada na escala de Indiana e a biométrica obtida pela biomicroscopia ultra-sônica. Não houve aplanamento da curva tonométrica apesar desta ter diminuído 32%. Não foi observada mudança significativa no vício de refração ou na acuidade visual após a operação. A biomicroscopia ultra-sônica demonstrou uma associação inversa entre um maior número de complicações pós-operatórias e o tamanho menor do óstio interno da trabeculectomia. / INTRODUCTION: It is important to study the trabeculectomy effectiveness and strategies to keep its action within long time. To improve the prognostic presented on glaucoma surgical reviews it is essential to understand better the bleb structure and its possible cause of failing. Alternative ways of restoring the drainage and the good performance of trabeculectomy have been studied, among them the Internal Revision of Simmons. PURPOSE: Evaluate the surgery effects on the IOP; on the biomicroscopic aspect of the bleb and its co-relation with biometric founding gotten through UBM. METHODS: For six months, 29 patients with open angle glaucoma who had been submitted to trabeculectomy before, for at least three months, with IOP above the expected to the control of glaucoma, despite the medication used, were included and studied in a prospective way. These patients should present the conjunctive tissue not too scarry and internal ostio of trabeculectomy present on the gonioscopia. The success criterion was: lowering the IOP, equal or above 30% on pre-operatory IOP and/or final pressure below 15 mmHg, with or without eye drops. RESULTS: There was a statistically fall of IOP and amount of medication used after the surgery. The average of IOP before surgery was 23.27 ± 4.10 mmHg and at the end of study was 15.04 ± 4.00 mmHg (p=0.000016). The average of the IOP curve pressure before surgery was 22.36 ± 3.91mmHg, dropped to 15.01 ± 4.0 mmHg at PO180d (p=0.0000001). Before the surgery the average of medication used was 2.1 ± 0.77 and at the end of the study it was 1.22 ± 1.01 (p=0.001117). There was an increase of the filtering bleb size clinically measured. The blebs had an average height of 0.28 ± 0.65 and at the end of the study their height was 0.78 ± 0.85 (p=0.000016). The UBM didn?t show any difference in the bleb size. The intra-ocular pressure presented an inversely proportional relation to the dimension of the filtering bleb, with statistic significance. The most frequently problems found were: detachment of Descemet membrane where the main incision was performed, in 5 (17.28%) patients; hole in the conjuntiva in 4 (13.88%), detachment of the choroid in 3 (10.38%). CONCLUSIONS: The surgery was effective, for provided 30% decrease of initial IOP in 52% without or with eye drops statistically in small number than in presurgery. The blebs have appeared, statistically, bigger after the procedure. There was a perfect correlation between the bleb height classification, within the clinical measurement, based on the Indian scale, and the biometric one, gotten by UBM. There was no flattening of the IOP curve pressure despite this one had been 32% lower than the initial one. No significant change has occurred in the vicious of refraction or in the visual accuracy after the surgery. The UBM demonstrated an association between a larger number of complications post-surgery and the internal size of the trabeculectomy ostio.
110

Influência da ceratometria e profundidade de câmara anterior obtidas por biometria óptica e por sistema Scheimpflug na predição do poder dióptrico de lente intraocular multifocal calculada para emetropia / Influence of keratometry and anterior chamber depth obtained by partial coherence interferometry and Scheimpflug system in the accuracy of intraocular multifocal lens diopter power calculated for emmetropia

Andrade Junior, Newton 26 September 2018 (has links)
Influência da ceratometria e profundidade de câmara anterior obtidas por interferometria de coerência parcial e por sistema Scheimpflug na acurácia do poder dióptrico de lente intraocular multifocal calculada para emetropia [Tese]. São Paulo: Faculdade de Medicina, Universidade de São Paulo; 2018. Objetivo: Verificar se a ceratometria média (K) e a profundidade de câmara anterior (ACD) obtidos por biometria óptica (IOLMaster® 500) e por sistema Scheimpflug (Pentacam® HR) influenciam na predição do cálculo do poder dióptrico de LIO multifocal programada para emetropia. Métodos: Estudo clínico retrospectivo de 198 olhos portadores de catarata senil, tratados com facoemulsificação e implante de LIO multifocal. A diferença entre o valor da ¨LIO ideal¨, previsto pela fórmula biométrica de HAIGIS para emetropia e o poder dióptrico da LIO implantada foi denominada \"desvio teórico da emetropia\" (TDE). Foram testados quatro cenários de cálculo de LIOs, combinando as medidas K e ACD obtidas com os dois dispositivos. Resultados: No trigésimo dia de pós-operatório, o equivalente esférico foi 0 D em 118 dos 198 olhos (60%). O IOL Master® 500 e Pentacam® HR diferiram em relação à média de K (delta 0,09 ± 0,02 D, p < 0,001) e ACD (delta 0,08 ± 0,01 mm; p < 0,001). De acordo com a análise de covariância, o TDE foi 0,17 ± 0,01 D para K e ACD mensurados com IOL Master® 500; 0,27 ± 0,01 D para K e ACD obtidos com Pentacam® HR; 0,15 ± 0,01 D para K gerados com IOL Master® e ACD medidos com Pentacam® HR e 0,28 ± 0,01 D para K mensurado com Pentacam® HR e ACD obtido com IOL Master®. O TDE foi menor quando K foi medido com IOL Master® 500, independente de qual dispositivo foi usado para medir ACD. Conclusões: As predições foram menos confiáveis usando o K gerado pelo Pentacam® HR (diferença média > 0,25D), a despeito de qual equipamento tenha gerado a ACD / Objective: To compare the postoperative refractive predictability of IOL Master® 500 and Pentacam® HR based on K and ACD values in eyes with indication for multifocal IOLs. Methods: Clinical retrospective study of 198 consecutive eyes treated with phacoemulsification and multifocal IOL implantation. The difference between the predicted value and the ideal IOL diopter was termed theoretical deviation from emmetropia (TDE). Using Haigis\' formula, the IOL closest to emmetropia was chosen. Four lens calculation scenarios were tested by combining K and ACD measurements obtained with the two devices. Results: On the 30th postoperative day, the spherical equivalent was 0 D in 118 of the 198 eyes (60%). IOL Master® and Pentacam® HR differed with regard to mean K (delta 0.09 ± 0.02 D; p < 0.001) and ACD (delta 0.08 ± 0.01 mm; p < 0.001). According to the analysis of covariance, TDE was 0.17 ± 0.01 D for K and ACD measured with IOL Master®, 0.27 ± 0.01 D for K and ACD measured with Pentacam HR; 0.15 ± 0.01 D for K measured with IOL Master® and ACD measured with Pentacam® HR, and 0.28 ± 0.01 D for K measured with Pentacam HR and ACD measured with IOL Master®. Mean K was the only statistically significant factor (p < 0.001). Thus, TDE was smaller when K was measured with IOL Master® 500, regardless of which device was used to measure ACD. Conclusion: Predictions were less reliable using the K generated by Pentacam® HR (average difference > 0,25D), regardless of which equipment has generated the ACD