• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 931
  • 737
  • 287
  • 105
  • 35
  • 35
  • 35
  • 35
  • 33
  • 26
  • 23
  • 12
  • 10
  • 10
  • 8
  • Tagged with
  • 3553
  • 737
  • 638
  • 593
  • 553
  • 533
  • 331
  • 316
  • 315
  • 251
  • 242
  • 183
  • 182
  • 161
  • 156
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
521

Caracterização do LiNbO3:Er+3 como meio ativo para lasers de estado sólido através dos espectros de absorção/emissão polarizada e medida dos tempos de vida de luminescência. / Characterization of LiNbO3:Er+3 as active media for solid-state lasers through polarized absorption/ emission spectra and measurements of luminescence lifetime.

Milori, Debora Marcondes Bastos Pereira 20 September 1989 (has links)
Este trabalho consiste na caracterização ótica de monocristais de LiNbO3: Er+3, visando a possibilidade deste sistema ser meio ativo para laser. Os resultados obtidos para absorção e emissão foram satisfatórios, sendo bastante compatíveis com os do modelo teórico adotado. O tempo de vida de luminescência das transições 4S3/2 - 4I15/2 e 4F9/2 - 4I15/2 foi medido, à temperatura ambiente e de nitrogênio líquido, mostrando que elas são possíveis candidatas a transições laser. Também foi feito um estudo sobre o comportamento das concentrações das impurezas indesejáveis OH- e Fe2+, através de tratamento térmico. O controle dessas concentrações foi feito através das técnicas de RPE e absorção ótica e os resultados mostraram que é perfeitamente possível eliminar tais impurezas de uma forma totalmente controlada. / This work consists in the optical characterization of LiNbO3:Er3+ single crystals, aiming to verify the possibility of this system being an active media for laser. The absorption and emission results were satisfactory, being compatible enough with the theoretical model adopted. The luminescence lifetime of the 4S3/2 - 4I15/2 e 4F9/2 - 4I15/2 transitions was measured at the ambient and liquid nitrogen temperature, showing that they are possible candidates for laser transitions. The behavior of the undesirable OH- and Fe2+ impurities was also studied through thermal treatment. The control of these concentrations was done using the EPR and optical absorption techniques and the results showed it is possible to eliminate such impurities in a totally controlled way.
522

Avaliação do efeito do laser de baixa intensidade na regeneração de defeitos ósseos de tamanho crítico preenchidos com osso autógeno ou xenógeno associados à membrana colágena / Evaluation of the effect of low-level laser therapy on the regeneration of critical size defects filled with autogenous bone or xenogenous bone associated to collagenous membrane

Nicole Rosa de Freitas 06 July 2018 (has links)
O objetivo deste estudo foi avaliar o efeito do laser de baixa intensidade (LBI), na regeneração de defeitos de tamanho críticos preenchidos com osso autógeno ou Bio-Oss® associados à membrana colágena. O estudo foi conduzido em 120 defeitos críticos (5 mm) em calvárias de ratos machos (Rattus norvegicus, albinus, Wistar), pesando entre 250 a 300g, divididos em 12 grupos experimentais (n=10): 1) Grupo C (Controle coágulo sanguíneo); 2) Grupo M (membrana colágena- BioGide®); 3) L (laser de baixa intensidade, GaAlAs, 808 nm, 100 mW, 6J, 210 J/cm2); 4) Grupo OA (osso autógeno); 5) Grupo OA/L (osso autógeno + LBI) 6) Grupo OA/M (osso autógeno + membrana colágena); 7) Grupo L/M (LBI + membrana colágena); 8) Grupo OA/L/M (osso autógeno + LBI + membrana colágena); 9) Grupo BO (Bio-Oss®); 10) Grupo BO/M ( Bio-Oss® + membrana colágena) 11) Grupo BO/L (Bio-Oss®+ LBI); 12) Grupo BO/L/M (Bio-Oss® + LBI + membrana colágena). Aos 30 dias pós-operatórios os animais foram sacrificados e após o processamento tecidual, foram realizadas análises histológica, histométrica e estatística. Os dados foram submetidos ao teste paramétrico ANOVA, seguido pelo teste de Tukey (p<0,05). As variáveis analisadas foram: área de osso neoformado (AON) e área de partículas residuais (APR). Todos os grupos apresentaram maiores quantidades de AON quando comparados ao grupo C (9,96% ± 4,49%). Quando o LBI foi associado aos biomateriais apresentou diferença estatística signicativa somente no grupo BO/L (48,57% ± 28,22%, p < 0,05). Menor APR foi encontrada nos grupos irradiados pelo LBI, com diferença estatística significativa para o grupo BO/L (16,74% ± 15,25%, p < 0,05). O LBI possui efeito positivo na regeneração óssea de DTC, e embora na análise estatística tenha apresentado diferença significante somente quando aplicado sobre o Bio-Oss®, na análise histomorfométrica foi possível observar formação óssea em extensões variadas nos demais grupos. / The purpose of the study was to evaluate the effect of low-level laser therapy (LLLT) on guided bone regeneration of critical size defects filled with autogenous bone or Bio- Oss® associated with the collagen membrane. The study was conducted in 120 critical size defects (5mm) in male rats (Rattus norvegicus, albinus, Wistar),weighing between 250 and 300g, divided into 12 experimental groups (n = 10): 1) Group C (control only blood clot); 2) Group M (collagen membrane- BioGide®); 3) Group LLLT (low-level laser therapy, GaAlAs, 808 nm, 100 mW, 6J, 210 J/cm2); 4) Group AB (autogenous bone); 5) Group AB/LLLT (autogenous bone + LLLT); 6) Group AB/M (autogenous bone + collagen membrane); 7); Group LLLT/M (LLLT + collagen membrane) 8) Group AB/LLLT/M (autogenous bone + LLLT + collagen membrane); 9) Group BO (Bio-Oss®); 10) Group BO/M (Bio-Oss® + collagen membrane) 11) Group BO/LLLT (Bio-Oss® + LLLT), 12) Group BO/LLLT/M Bio- Oss® + LLLT + collagen membrane). The animals were killed 30 days postoperatively. After tissue processing, bone regeneration was evaluated by histomorphometric and statistical analysis was performed (Tukey test, p<0,05). The variables analyzed were the area of newly formed bone (NFB) and residual particle area (RPA). All groups presented greater amounts of AON when compared to group C (9,96% ± 4,49%). When LBI was associated with biomaterials, it showed a significant statistical difference only in the BO/L group (48,57% ± 28,22%, p<0,05). Smaller APR was found in the groups irradiated by LBI, with a significant statistical difference for BO/L group (16,74% ± 15,25%, p<0,05). LBI has a positive effect on bone regeneration of DTC, and although in the statistical analysis it presented significant difference only when applied on Bio-Oss®, in the histomorphometric analysis it was possible to observe bone formation in varied extensions in the other groups.
523

Desenvolvimento de um laser pulsado de Nd : YAG de alta radiância para aplicações em óptica não-linear

André César da Silva 01 August 1988 (has links)
Foi projetada uma cavidade óptica estável incorporando um telescópio de magniticação 3, para a obtenção de um laser pulsado de Nd:YAG de alta radiância. São verificadas as seguintes vantagens deste tipo de cavidade sobre as cavidades usuais: 1) a potência do laser é menos sensível ao alinhamento dos espelhos; 2) permite o casamento do volume do modo fundamental transversal com o volume do meio ativo, possibilitando a extracação de máxima energia neste modo; 3) o fator de estabilidade pode ser ajustado pela defocagem do telescópio para a condição de máxima estabilidade; 4) as caracteristicas do feixe são insensíveis às flutuações da lente térmica, às distância e ao arranjo dos componentes na região do feixe expandido; 5) oferece alta reprodutibilidade dospulsos de laser em termos de qualidade óptica, independente da taxa de repetição ou da energia de bombeamento.
524

Geração e amplificação de fônons em amostras de Ni irradiadas por pulsos de laser de CO2

Nicolau André Silveira Rodrigues 01 January 1989 (has links)
Neste trabalho é relatada a observação experimental da amplificação termoelétrica de ondas elásticas em alvos de Ni iluminados por pulsos intensos de laser de CO2-TEA. Foram utilizadas duas técnicas distintas para a monitoração da amplitude das ondas elásticas: uma de contato, usando um transdutor de PVDF, e uma remota, baseada no efeito Mirage (deflexão de feixe). No caso das medidas por deflexão de feixe, foi realizada a transformada de Fourier do sinal elétrico correspondente ao pulso acústico e as análises foram feitas para cada componente em freqüência dos mesmos. Foram também variados os parâmetros: refletividade e espessura da amostra e duração do pulso do laser. Em todos os casos os resultados concordaram bem com os previstos teoricamente.
525

Resistência de união à dentina de sistemas adesivos irradiados com laser de diodo: estudo in vitro / Bond strength to dentin with adhesive systems irradiated with diode laser: in vitro study

Maenosono, Rafael Massunari 26 March 2013 (has links)
A irradiação LASER sobre os sistemas adesivos aplicados em dentina, antes de sua fotoativação, tem sido proposta para aumentar a resistência de união de restaurações adesivas. O objetivo foi avaliar o efeito da irradiação com LASER de Diodo (&#x3BB; = 970nm) sobre diferentes sistemas adesivos na resistência de união imediata à dentina. Oitenta molares humanos hígidos foram aleatoriamente distribuídos em 8 grupos (n=10) de acordo com o sistema adesivo: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus - convencional não simplificado), SB (Adper&#x2122; SingleBond 2 - convencional simplificado), CSE (Clearfil&#x2122; SE Bond - autocondicionante não simplificado), EO (Adper&#x2122; EasyOne - autocondicionante simplificado); e respectivos grupos irradiados com LASER de Diodo (SiroLaser, Sirona Dental). Para avaliar a resistência de união foi realizado teste de microtração, obtendo-se valores em MPa, posteriormente analisados através de ANOVA a 2 critérios, seguido de Tukey para comparações individuais e múltiplos testes t (p<0,05) para comparações entre CONTROLE e LASER do mesmo sistema adesivo. Os valores de resistência de união ± desvio padrão para os grupos sem e com irradiação com LASER foram respectivamente: MP (40,10±10,95 / 35,82±7,17), SB (33,49±6,77 / 43,69±8,15), CSE (43,71±15,71 / 37,95±7,66) e EO (19,67±5,86 / 29,87±6,98). A irradiação com LASER de Diodo provocou um aumento da resistência de união obtida pelos sistemas adesivos SB e EO, mostrando-se uma técnica promissora na obtenção de uma adesão mais efetiva de sistemas adesivos simplificados ao substrato dentinário. / LASER irradiation on adhesive systems before it`s activation has been proposed to increase bond strength of composite restorations to dentin. The objective was to evaluate the effect of Diode LASER irradiation (&#x3BB; = 970nm) on different adhesive systems on immediate bond strength to dentin. Eighty healthy human molars were randomly distributed in 8 groups (n=10) according to the adhesive system: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus, non simplified etch and rinse), SB (Adper&#x2122; SingleBond 2 simplified etch and rinse), CSE (Clearfil&#x2122;SE Bond non simplified self-etch), EO (Adper&#x2122; EasyOne simplified self-etch); and respective groups irradiated with Diode LASER (SiroLaser, Sirona Dental). Microtensile test was performed obtaining bond strength values in MPa whice were analyzed by two way ANOVA, followed by Tukey for individual comparisons and multiple t test (p<0.05) for evaluation of CONTROL and LASER groups with the same adhesive systems. Bond strength values ± standard deviation for groups without and with LASER irradiation were respectively: MP (40.10±10.95 / 35.82±7.17), SB (33.49±6.77 / 43.69±8.15), CSE (43.71±15.71 / 37.95±7.66) and EO (19.67±5.86 / 29.87±6.98). Irradiation with Diode LASER resulted in an increase of SB and EO bond strength values, being considered a promising technic to obtain an improved adhesion of simplified adhesive systems to dentin substrate.
526

Efeito da variação da densidade de energia da ponta e da frequência na resistência de união à dentina de sistema adesivo convencional irradiado com diferentes laseres de alta potência / Variation of the effect of the energy density of the fiber tip and frequency in bond strength to irradiated conventional dentin bonding system with different high-power LASERs

Cardia, Guilherme Saintive 15 September 2015 (has links)
O objetivo deste estudo foi comparar o efeito da irradiação de dois tipos de laser (laser Nd:YAG e de Diodo) sobre um sistema adesivo convencional de três passos, utilizando três diferentes densidades de energia da ponta, na resistência de união imediata e após 1 ano. Foram selecionados 70 dentes humanos e cada um teve sua coroa seccionada, expondo a superfície da dentina necessária para os procedimentos adesivos e restauradores. Após o preparo dos dentes, os mesmos foram aleatoriamente subdivididos em 7 grupos (n=10), sendo 6 grupos-teste e um grupo controle. Na sequência, foi aplicado o sistema adesivo Scotchbond&#x2122; Multi- Purpose Plus e, antes de sua fotoativação, em três grupos, o laser Nd:YAG foi utilizado com 3 diferentes densidades de energia (1 509,55 J/cm2, 2 254,77 J/cm2 e 3 127,38 J/cm2), o mesmo procedimento com as mesmas densidades foi realizado nos três demais grupos com o laser de Diodo. Após a irradiação seguida da fotoativação, os dentes foram restaurados com incrementos de resina composta Filtek&#x2122; Z250. Os dentes restaurados foram então imersos em água deionizada e mantidos em estufa a 37oC por um período de 7 dias. Após o armazenamento, os espécimes foram seccionados de modo que se obtivessem palitos com área transversal de aproximadamente 1mm2. De forma aleatória, estes palitos foram separados em 2 grupos: o primeiro submetido imediatamente a testes de microtração em uma máquina de ensaio universal INSTRON 3342 e segundo submetido ao mesmo processo após 1 ano de armazenamento. Os valores de resistência de união foram submetidos aos testes ANOVA e post hoc de Tukey, para que comparações individuais pudessem ser realizadas. Não houve diferença estatisticamente significante entre os lasers utilizados. Os grupos irradiados com ambos os lasers apresentaram resultados similares ao grupo controle, com exceção ao grupo que utilizou o laser de Diodo com menor densidade de energia da (GD3), no qual o resultado foi inferior ao grupo controle no momento imediato. Quedas significativas nos valores de resistência de união foram observadas, com exceção aos grupos que utilizaram o laser de Diodo (GD3 GD2) e o laser Nd:YAG (GNd3). Os diferentes lasers não apresentaram diferença entre si e não foram capazes de promover aumento na resistência e união imediata comparados ao grupo controle. Todos os grupos obtiveram quedas na resistência de união, mesmo em alguns grupos esta queda não sendo significativa. Alterações de alguns parâmetros ou até mesmo a utilização de outro tipo de LASER poderiam ajudar a definir o protocolo ideal para o uso efetivo deste sistema de tratamento adjunto. / The aim of this work was to compare the effect of the irradiation of two types of laser (Nd:YAG and diode laser) on a conventional three-step adhesive system, using three different energy densities of the fiber tip in bond strength immediately and after 1 year. 70 human teeth were selected, and each one had the crown sectioned, exposing the dentin surface for the adhesive and restorative procedures. After teeth preparation, they were randomly divided into 7 groups (n = 10), being 6 test-groups and one control group. Thus, the bonding system Scotchbond&#x2122; Multi-Purpose Plus was applied, and before light cured, the Nd:YAG laser was used in three groups, with three different energy densities of the fiber tip (1 - 509.55 J/cm2, 2 - 254.77 J/cm2 and 3 - 127.38 J/cm2), the same procedures with the same energy densities of the fiber tip were performed for the diode laser. After irradiation followed by light cured, the teeth were restored with composite resin increments (Filtek&#x2122; Z250). The restored teeth were immersed in deionized water and maintained in oven at 37oC for 7 days. After storage, the specimens were sectioned in order to obtain sticks with crosssectional area of approximately 1mm2. Randomly, these sticks were divided into 2 groups: the first one was submitted immediately to microtensile tests in a universal testing machine INSTRON 3342, and the second group was submitted to the same procedure after one year of storage. The bond strength values were submitted to ANOVA and Tukey post hoc tests for individual comparisons. There was no statistically significant difference between the laser s. Irradiated groups showed similar results to the control group, except for the group that used the diode laser with lower energy density of the fiber tip (GD3), in which the results were lower than the control group in the immediate moment. Significant reduction in the values of bond strength were observed, except for the groups that used the diode laser (GD3 - GD2), and the Nd:YAG laser (GNd3). Different lasers did not differ among themselves and were not able to promote an increase in resistance and immediate union compared to the control group. All groups had declines in bond strength, even in some this fall not significant groups. Changes in some parameters or even the use of another type of laser could help define the optimal protocol for the effective use of this adjunctive treatment system.
527

Influência da irradiação com lasers de alta potência na microinfiltração bacteriana e fúngica em dentes humanos retrobturados com MTA / High power lasers Influence in bacterial and fungical microleakage in MTA retrofills

Aun, Carmo Antonio 02 April 2008 (has links)
Este estudo experimental avaliou, in vitro, a microinfiltração de E. faecalis e C. albicans em raízes cujas superfícies apicais ressectadas e retropreparadas para obturação retrógrada sofreram irradiação dos lasers Nd:YAG, Diodo 810 nm e Er,Cr:YSGG, e posteriormente retrobturadas com MTA. Setenta raízes foram instrumentadas, obturadas endodonticamente, apicectomizadas e receberam retropreparos com pontas ultra-sônicas diamantadas e lisas na potência média. A divisão dos espécimes se deu de acordo com o laser utilizado e o tipo de microorganismo. Os grupos G1 e G5 não foram irradiados, G2 e G6 irradiados com Nd:YAG, G3 e G7 com Diodo e G4 e G8 com Er,Cr:YSGG (n = 8). Foram utilizados controles positivo (n = 3) e negativo (n = 3). Todos os procedimentos operatórios foram realizados com um dispositivo de simulação de dificuldades operatórias. Após a impermeabilização, colagem das raízes em tubos preparados, esterilização e retrobturação com MTA branco, o sistema de câmaras superior, contendo o inóculo de microorganismos, e inferior, contendo meio esterilizado foi montado em contato com o ápice. Os grupos G1 a G4 foram inoculados com E. faecalis, e os grupos G5 a G8 com C. albicans. A troca de meio na câmara superior se deu a cada 3 dias e a verificação da turvação do meio inferior era diária, por um período de 60 dias. Ao final, os resultados indicaram que: o controle positivo apresentou 100% de microinfiltração, o controle negativo não microinfiltrou e os grupos experimentais apresentaram padrões de microinfiltração que variaram entre 50% (G1) e 100% (G2) de microinfiltração, onde 68,75% do total de espécimes microinfiltraram. Não houve diferença estatística significativa entre os grupos aplicando-se os testes Exato de Fischer e Kruskal-Wallis (p > 0,05) em nenhuma interação. Pode-se concluir que o tratamento das retrocavidades e superfície apical ressectada, com os lasers utilizados neste estudo, não alterou o padrão de microinfiltração das retrobturações com MTA frente a E. faecalis e C. albicans. O tipo de microorganismo utilizado também não alterou a quantidade de espécimes microinfiltrados. / This in vitro experimental study evaluated the microleakage of E. faecalis and C. albicans in roots whose ressected apical surfaces and retrocavities had suffered irradiation from Nd:YAG, Diode 810 nm and Er,Cr:YSGG lasers, and later retrofiled with MTA. Seventy roots had been prepared, obturated, had suffered apicoectomy and were retroprepared with diamond and conventional ultra-sonic tips in the average power. The division of specimens was in accordance with the used laser and the type of microorganism. The groups G1 and G5 had not been irradiated, G2 and G6 irradiated with Nd:YAG, G3 and G7 with Diode and G4 and G8 with Er, Cr:YSGG (n = 8). Positive (n = 3) and negative (n = 3) controls had been used. All procedures executed until this point had been carried inside an access difficulties simulation device. After the waterproofing, attachment of the roots in prepared tubes and sterilization, the retrofillings were made using white MTA. The superior chambers were inoculated with the microorganisms and inferior chambers were completed with sterile culture broth in contact with the root tip. The G1, G2, G3 and G4 groups had been inoculated with E. faecalis and the rest of the groups with C. albicans. The contaminated broths of the upper chambers were exchanged each 3 days and for 60 days the verification of the turbidity in the inferior chambers was evaluated daily. At the end, the results had indicated that: the positive control had 100% microleakage, the negative control none and the experimental groups had presented microleakege patterns that range from 50% (G1) to 100% (G2), with a total of 68.75% of all specimens presenting microleakage. Applying the Exact Fischer test and Kruskal-Wallis test (p > 0,05), no significant statistical difference between the groups were observed in any interaction. It can be concluded that the treatment of the retrocavities and ressected apical surface, with the lasers used in this study, did not modify the rate of E. faecalis and C. albicans microleakage in MTA retrofillings. Also the type of used microorganism did not seem to modify the amount of microleakage in the specimens.
528

Estudo in vitro da microinfiltração em restaurações de cavidades classe V preparadas com alta rotação e lasers Er:YAG e Er, Cr:YSGG, utilizando-se dois sistemas adesivos / IN VITRO STUDY OF THE MICROLEAKAGE IN CLASS V CAVITIES RESTORATIONS PREPARED WITH AIR TURBINE AND LASERS Er:YAG AND Er,Cr:YSGG, AND BEING USED TWO ADHESIVE SYSTEMS

Moldes, Vera Lucia 19 February 2004 (has links)
RESUMO O objetivo deste estudo foi comparar o grau de microinfiltração nas margens gengival e incisal de restaurações classe V frente aos seguintes métodos de preparo: 1) alta rotação, 2) laser – Er:YAG modelo Opus 20 (Opus Dent) e 3) laser – Er,Cr:YSGG modelo Waterlase (Millennium, Biolase). Foram avaliados também os sistemas adesivos Single Bond (3M ESPE) e One-Up Bond F (Tokuyama). Sessenta incisivos bovinos hígidos, extraídos foram divididos em 6 grupos de 10 elementos. As cavidades foram preparadas de acordo com o protocolo a seguir: grupo 1 e 2 utilizando alta rotação, grupo 3 e 5 laser de Er:YAG, grupo 4 e 6 laser de Er,Cr:YSGG. Os espécimes foram restaurados com resina composta Z250 (3M ESPE) com a utilização prévia dos adesivos Single Bond (grupos 1, 3 e 4) e One-Up Bond F (grupos 2, 5 e 6). Após armazenagem em água destilada a 37ºC por 24h, os espécimes foram polidos, termociclados e imersos em solução de nitrato de prata a 50% por 8h. Os espécimes foram incluídos, seccionados em duas porções e revelados à 10min de exposição sob lâmpada phothoflood. Os corpos-de-prova infiltrados foram avaliados em lupa estereomicroscópica com 25 vezes de aumento a fim de detectar o grau de microinfiltração de cada uma das margens. A mais infiltrada foi escolhida para representar o resultado individual de cada corpo-de-prova. Foram realizadas fotos, e encaminhadas a três examinadores utilizando o método de escores 0, 1, 2 e 3. Os dados obtidos foram submetidos à análise estatística através do teste estatístico não paramétrico de Kruskal-Wallis. Na margem gengival houve maior microinfiltração no preparo realizado com laser Er:YAG do que com alta rotação com o sistema adesivo Single Bond. Na margem gengival com os preparos de lasers Er:YAG e Er,Cr:YSGG, observou-se menor microinfiltração com a utilização do sistema adesivo autocondicionante One-Up Bond F. A margem incisal não apresentou diferenças nos graus de microinfiltração para todos os tratamentos. / SUMMARY The aim of this research was compare the microleakage degree in the class V gingival and incisal margins using following preparation methods: 1) air turbine, 2) laser – Er:YAG Opus 20 (Opus Dent) and 3) laser – Er,Cr: YSGG Waterlase model (Millennium, Biolase). Also, the adhesive systems Single Bond (3M ESPE) and One-Up Bond F (Tokuyama) were evaluated. Sixty intact bovine incisives were divided in 6 groups of 10 elements each. The cavities were prepared as follow: groups 1 and 2 using air turbine, groups 3 and 5 laser Er:YAG, groups 4 and 6 laser Er,Cr:YSGG prepare. The specimens were restored with composite resin Z250 (3M ESPE) with previous utilization of the Single Bond (groups 1, 3 and 4) and One-Up Bond F (groups 2, 5 and 6). After storage in distilled water at 37°C, for 24 hours, the specimens were polished, thermocycled and immersed in 50% silver nitrate for 8h. The specimens were included, sectioned in two parts and revealed by means of a 10 min exposure photoflood lamp. The infiltered specimens were evaluated using a stereomicroscope glass with 25X magnification to detect the microleakage degree of each part. The more infiltrate was chosen to represent the individual result of each specimen. Photos were accomplished, and sent to three examinators using the method of scores 0, 1, 2 and 3. The obtained data were submitted to a statistical analysis using the non-parametrical statistic test of Kruskal-Wallis. In the gingival margin there was more microleakage with the prepare accomplished with laser Er:YAG, than that of air turbine with the Single Bond adhesive system. In the gingival margin with the lasers preparations Er:YAG and Er,Cr:YSGG smaller microleakage was observed with the use of self-etching One-Up Bond F adhesive system. The incisal margin did not present differences in the degrees of microleakage for all treatments.
529

Short laser pulses generation by moving-mirror method.

January 1993 (has links)
by Kwok Chi Wing. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1993. / Includes bibliographical references. / Abstract / Acknowledgements / Chapter 1. --- Introduction --- p.1 / Chapter 2. --- Basic Concepts of Lasers and Simple Survey of Laser Theories --- p.4 / Chapter 2.1 --- Introduction --- p.4 / Chapter 2.1.1 --- Basic Structure of a Laser --- p.4 / Chapter 2.1.2 --- "Concepts of "" Mode"" arid "" Mode-Locking""" --- p.6 / Chapter 2.2 --- Brief Review of Laser Theories --- p.9 / Chapter 2.3 --- Other Simple Models --- p.12 / Chapter 2.4 --- Review of the Maxwell-Bloch Equations --- p.17 / Chapter 2.4.1 --- Derivation of Maxwell-Bloch Equations --- p.17 / Chapter 2.4.2 --- Continuous-Wave Operation --- p.23 / Chapter 2.4.3 --- Mean-Field Approximation and Lorenz-Haken Instability --- p.24 / Chapter 2.4.4 --- Adiabatic Elimination of Fast Variables --- p.26 / Chapter 2.4.5 --- Thin-Sheet-Gain Approximation for Multimode Lasers --- p.30 / Chapter 2.4.6 --- Self-Mode-Locking Predicted by Using Maxwell-Bloch Equations --- p.33 / Chapter 2.4.7 --- Hysteresis Phenomena in Switching the Cavity Detuning --- p.35 / Chapter 3. --- "Moving-Mirror ""Mode-Locking""" --- p.41 / Chapter 3.1 --- Conventional Laser Mode-Locking --- p.41 / Chapter 3.1.1 --- Preliminaries: What is Mode-Locking (Conventional) ? --- p.41 / Chapter 3.1.2 --- Active Mode-Locking and Passive Mode-Locking --- p.43 / Chapter 3.1.3 --- Spectra of Conventional Mode-Locked Lasers --- p.49 / Chapter 3.2 --- Moving-Mirror Mode-Locking --- p.50 / Chapter 3.2.1 --- Historical Notes --- p.50 / Chapter 3.2.2 --- Previously Proposed Explanations --- p.54 / Chapter 3.3 --- MMML Mechanism: our Proposal --- p.59 / Chapter 3.3.1 --- Relation between MMML Lasers and FSFC Lasers --- p.60 / Chapter 3.3.2 --- Concept of Moving Modes --- p.62 / Chapter 3.3.3 --- How are the Moving Modes Locked ? --- p.64 / Chapter 3.4 --- Numerical Simulations ´ؤ Method and Results --- p.68 / Chapter 3.4.1 --- Description of Our Numerical Model --- p.68 / Chapter 3.4.2 --- Tests on the Simulation Method --- p.71 / Chapter 3.4.3 --- Ultrashort Pulses Generation of a MMML Laser --- p.73 / Chapter 3.4.4 --- Modulation of the Pulses --- p.74 / Chapter 3.4.5 --- Broadband or Discrete Spectra ? --- p.75 / Chapter 3.4.6 --- Different Operation Regimes in MMML Lasers --- p.79 / Chapter 3.4.7 --- Why Period-T/2 Pulses --- p.84 / Chapter 3.4.8 --- Auto-Correlation Function of the Electric Field --- p.86 / Chapter 3.4.9 --- FSFC Laser with Injection Signal --- p.87 / Chapter 3.4.10 --- MMML in Class C Laser: d = 1.0 --- p.88 / Chapter 3.4.11 --- Exciting the Relaxation Oscillation Resonance --- p.89 / Chapter 4. --- Discussion and Conclusion --- p.92 / Chapter 4.1 --- Limitation of (Conventional) Thin-Sheet-Gain Approximation --- p.92 / Chapter 4.1.1 --- Problem with the Conventional Thin -Sheet-Gain Approximation --- p.92 / Chapter 4.1.2 --- Modified Thin-Sheet-Gain Approximation --- p.93 / Chapter 4.2 --- Concluding Remarks; Possibilities of Further Research --- p.97 / References and Notes / Appendix: Source Codes of the Fortran Program
530

Narrow linewidth tunable solid state lasers based on dye-doped sol-gel derived silica =: 窄線寬固體顔料激光的產生. / 窄線寬固體顔料激光的產生 / 窄線寬固體顔料激光的產生 / Narrow linewidth tunable solid state lasers based on dye-doped sol-gel derived silica =: Zhai xian kuan gu ti yan liao ji guang de chan sheng.

January 1995 (has links)
by Lam King Shun. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1995. / Includes bibliographical references (leaves [40-41]). / by Lam King Shun. / Acknowledgement --- p.i / Biographical Sketch --- p.ii / Abstract --- p.iii / Table of Contents --- p.iv / Chapter Chapter One --- Introduction --- p.1 / Chapter Chapter Two --- The Sol-Gel Derived Silica / Chapter 2.1 --- Introduction to the so-gel science --- p.3 / Chapter 2.2 --- The procedure of the silica formation --- p.5 / Chapter 2.3 --- During the sol-gel process --- p.7 / Chapter 2.4 --- The silica characterization --- p.12 / Chapter 2.4.1 --- Physical properties --- p.12 / Chapter 2.4.2 --- Optical properties --- p.13 / Chapter 2.5 --- Sample preparation --- p.15 / Chapter Chapter Three --- Laser Experiments / Chapter 3.1 --- Basic principle of dye laser --- p.16 / Chapter 3.2 --- Experimental procedure --- p.20 / Chapter 3.3 --- Data and discussion --- p.23 / Chapter 3.3.1 --- Spectral and temporal behaviour --- p.2 3 / Chapter 3.3.2 --- The performance of the sol-gel silica laser --- p.37 / Chapter Chapter Four --- Conclusions and Suggestions for Further Work --- p.39 / References

Page generated in 0.6024 seconds