Spelling suggestions: "subject:"leachate."" "subject:"ieachate.""
311 |
Remoção de matéria orgânica em lixiviado de aterro sanitário utilizando contactor biológico rotatório / Removal of organic matter in landfill leachate using rotating biological contactorSantos, Vanessa Schweitzer dos 31 January 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-06-30T17:56:45Z
No. of bitstreams: 1
Vanessa Schweitzer dos Santos.pdf: 1081901 bytes, checksum: 117ce960501c8c561bd7ee102cf9254a (MD5) / Made available in DSpace on 2015-06-30T17:56:45Z (GMT). No. of bitstreams: 1
Vanessa Schweitzer dos Santos.pdf: 1081901 bytes, checksum: 117ce960501c8c561bd7ee102cf9254a (MD5)
Previous issue date: 2013-01-31 / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / Ministério da Ciência e Tecnologia / O lixiviado de aterro sanitário é um efluente gerado através da infiltração de águas pluviais nas camadas de cobertura do aterro e da biodegradação da fração orgânica dos resíduos sólidos urbanos aterrados. Caracteriza-se por um alto potencial poluidor e elevadas concentrações de matéria orgânica, portanto sua coleta e tratamento posterior são necessários. Sistemas biológicos podem ser aplicados no seu tratamento, visando remover matéria orgânica e nutrientes através das atividades metabólicas dos micro-organismos envolvidos no processo. Os contactores biológicos rotatórios são reatores cilíndricos que possuem em seu interior meios de suporte, onde a biomassa atua fixada, na forma de biofilme. Este entra em contato com o substrato através de rotação mecânica do tambor cilíndrico no efluente. Esta pesquisa teve como objetivo principal estudar a capacidade de remoção de matéria orgânica de lixiviado de aterro sanitário, através da utilização de um contactor biológico rotatório. O lixiviado do aterro sanitário de São Leopoldo/RS foi tratado por um contactor biológico rotatório de três estágios, que foi operado de duas formas. Uma deles foi com vazão de 8,5 L/h e tempo de retenção hidráulica de 15 h (Fase 1). Neste modo de operação a carga orgânica afluente média foi de 434 mg/L de DBO (limites entre 304 mg/L e 576 mg/L), 2484 mg/L de DQO (limites entre 882 mg/L e 3617 mg/L) e 992 mg/L de COT (limites entre 405 mg/L e 1420 mg/L). O outro modo de operação testado teve vazão de 5,1 L/h e tempo de retenção hidráulica de 24 h (Fase 2). A carga orgânica afluente média foi de 500 mg/L de DBO (limites entre 325 mg/L e 580 mg/L), 3818 mg/L de DQO (limites entre 2647 mg/L e 4764 mg/L) e 1250 mg/L de COT (limites entre 940 mg/L e 1360 mg/L). O lixiviado pesquisado apresentou como principal característica a baixa biodegradabilidade, além de ampla variação em sua composição ao longo do experimento, principalmente na Fase 1. Esta variação em sua composição pode ter afetado as eficiências de remoção de matéria orgânica, que foram de 50% de DBO, 11% de DQO e 13% de COT na Fase 1. Na Fase 2 os valores afluentes se mantiveram mais semelhantes, e as taxas de remoção de matéria orgânica foram mais constantes, além de que os valores médios de eficiência de remoção foram maiores do que os verificados na Fase 1. As eficiências de remoção na Fase 2 foram de 66% de DBO, 15% de DQO e 18% de COT. O aumento do tempo de retenção hidráulica na Fase 2 resultou em aumento da eficiência de remoção de matéria orgânica. Este efeito provavelmente está associado ao maior tempo de contato entre a biomassa e o substrato disponível no lixiviado de aterro sanitário. Quanto à remoção de matéria orgânica nos diferentes estágios do contactor biológico rotatório, foi observada uma maior eficiência nos dois primeiros estágios do sistema, principalmente dos parâmetros de DQO e COT, em ambas as fases monitoradas. Para o lixiviado e os modos de operação testados, o estágio 3 não apresentou eficiência que justifique sua presença, quanto aos parâmetros de DQO e COT. / The sanitary landfill leachate is an effluent generated by infiltration of rainwater into the layers of the landfill cover and biodegradation of the organic fraction of municipal solid waste grounded. It is characterized by a high pollution potential and high concentrations of organic matter, so their collection and further treatment is needed. Biological systems can be applied in their treatment in order to remove organic matter and nutrients through the metabolic activity of micro-organisms involved in the process. The rotating biological contactors are cylindrical reactors having inside support means, which acts fixed biomass in the form of biofilm. This comes into contact with the substrate by mechanical rotation of the cylindrical drum in the effluent. This research aimed to study the capacity of organic matter removal of landfill leachate, through the use of a rotating biological contactors. The landfill leachate São Leopoldo/RS was treated by a three-stage rotating biological contactor, which was operated in two modes. One was a flow rate of 8.5 L/h hydraulic retention time of 15 h (Phase 1). In this mode of operation the load influent organic average was 434 mg/L of BOD (limits between 304 mg/L and 576 mg/L), 2484 mg/L COD (limits between 882 mg/L and 3617 mg/L) and 992 mg/L of TOC (limits between 405 mg/L and 1420 mg/L). The other operation mode tested had a flow rate of 5.1 L/h and hydraulic retention time of 24 h (Phase 2). The average influent organic load was 500 mg/L of BOD (limits between 325 mg/L and 580 mg/L), 3818 mg/L COD (limits between 2647 mg/L and 4764 mg/L) and 1250 mg/L TOC (limits between 940 mg/L and 1360 mg/L). The researched showed landfill leachate as main characteristic the low biodegradability, and wide variation in composition throughout the experiment, especially in Phase 1. This variation in composition may have affected the removal efficiency of organic matter, which were 50% BOD, 11% COD and 13% TOC in Phase 1. In Phase 2 affluent values remained more similar, and the removal rates of organic matter were more constant, and that the average values of removal efficiency was higher than those observed in Phase 1. The removal efficiencies in Phase 2 were 66% BOD, 15% COD and 18% TOC. The increase in Phase 2 hydraulic retention time resulted in increased efficiency of removal of organic material. This effect is probably associated with greater contact time between the substrate and the biomass available in the landfill leachate. As for the removal of organic matter at different stages of rotating biological contactor, greater efficiency was observed in the first two stages of the system, particularly the parameters of COD and TOC in both phases monitored. For leachate and operating modes tested, stage 3 showed no efficiency to justify their presence, for the parameters COD and TOC.
|
312 |
Aplicação de ozônio e ozônio + peróxido de hidrogênio para remoção de compostos recalcitrantes em lixiviados de aterros sanitários / Application of ozone and ozone + hydrogen peroxide to remove of recalcitrant compounds in landfill leachatesSchoenell, Elisa Kerber 28 February 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-07-06T14:05:57Z
No. of bitstreams: 1
Elisa Kerber Schoenell.pdf: 1100203 bytes, checksum: 7fc798f66b493b73d31a96dbbf676ff3 (MD5) / Made available in DSpace on 2015-07-06T14:05:57Z (GMT). No. of bitstreams: 1
Elisa Kerber Schoenell.pdf: 1100203 bytes, checksum: 7fc798f66b493b73d31a96dbbf676ff3 (MD5)
Previous issue date: 2013-02-28 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / Ministério da Ciência e Tecnologia / Os lixiviados são efluentes gerados em depósitos de resíduos sólidos, através da decomposição da matéria orgânica, somados as águas de infiltração e a materiais suspensos. Ele possui compostos biodegradáveis e recalcitrantes - de difícil degradação biológica (biodegradação). Este efluente necessita de um tratamento antes de ser disposto no meio ambiente. O objetivo deste trabalho foi avaliar o uso de ozônio (O3) e peróxido de hidrogênio (H2O2) como processo oxidativo avançado (POA), visando a remoção de compostos recalcitrantes em lixiviados de aterros sanitários. Foram utilizados dois lixiviados provenientes do aterro sanitário de São Leopoldo/RS: bruto e tratado por lagoas, os quais foram tratados apenas por O3 em concentração de 29 mg/L (gerados a partir de processo corona) ou com adição de 1000 mg/L de H2O2 ao O3. Os ensaios ocorreram em escala piloto, sendo tratados 460 L de lixiviado em cada ensaio, os quais tiveram duração de 96 horas. O POA (operando com os oxidantes O3 e O3 + H2O2) mostrou-se mais eficiente no tratamento de lixiviados que tiveram as menores concentrações iniciais de DBO, DQO e COT, independente de ser lixiviado bruto ou tratado. Altas remoções de cor aparente, DQO e COT foram observadas, chegando a 99%, 88% e 66%, respectivamente. A maior remoção de carbono inorgânico foi 23%, porém o grupo que iniciou com a maior concentração desse parâmetro, obteve as maiores remoções para todos os outros parâmetros estudados. A adição de H2O2 aumentou a eficiência de remoção de todos os parâmetros analisados, porém não de forma significativa. Observou-se necessidade de tratamento complementar ao POA deste estudo. / Leachates are wastewaters generated at sites of solid waste disposal through organic matter decomposition, added to infiltration waters and suspended materials. It contains biodegradable and recalcitrant compounds - difficult to biological degradation (biodegradation). This wastewater requires treatment before being disposed in the environment. The aim of this study was to evaluate the use of ozone (O3) and hydrogen peroxide (H2O2) as advanced oxidation process (AOP), in order to removal recalcitrant compounds in landfill leachate. It was used two leachates from São Leopoldo/RS landfill: raw and treated in pounds, which were treated only with O3 at a concentration of 29 mg/L (generated from the corona process) or with addition of 1000 mg/L H2O2 to O3. The tests occurred on a pilot scale, treating 460 L of leachate in each test, which lasted 96 hours. OAP (operating with the oxidants O3 and O3 + H2O2) was more efficient in the treatment of leachate that had the lowest initial concentrations of BOD, COD and TOC (both raw and treated leachate).. High removals of apparent color, COD and TOC were observed, reaching 99%, 88% and 66%, respectively. The greater removal of inorganic carbon was 23%, but the group that started with the highest concentration of these parameter, achieve the greatest removals for all others parameters studied. The addition of H2O2 increased the efficiency of removal of all parameters, but not significantly. It was observed need of additional treatment to the POA of this study.
|
313 |
Avaliação da remoção de cor e desinfecção de lixiviados de aterro sanitário utilizando ozônio e peróxido de hidrogênio / Evaluation of color and disinfection of landfill leachate using ozone and hydrogen peroxideSeewald, Marina Medtler 28 February 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-07-06T19:15:18Z
No. of bitstreams: 1
Marina Medtler Seewald.pdf: 3415895 bytes, checksum: a88885e13dc4a2b54ba496bc5a0fd0b7 (MD5) / Made available in DSpace on 2015-07-06T19:15:18Z (GMT). No. of bitstreams: 1
Marina Medtler Seewald.pdf: 3415895 bytes, checksum: a88885e13dc4a2b54ba496bc5a0fd0b7 (MD5)
Previous issue date: 2013-02-28 / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / Ministério da Ciência e Tecnologia / A degradação de resíduos dispostos em aterro sanitário gera um líquido com alto potencial poluidor caracterizado por sua coloração escura, alto teor de matéria orgânica e de nitrogênio amoniacal. O lixiviado de aterro sanitário pode ainda conter micro-organismos patogênicos provenientes de resíduos contaminados com excreções humanas, representando risco à saúde. Para o tratamento de lixiviado de aterro sanitário, processos biológicos tem mostrado eficiência, especialmente na remoção de matéria orgânica. No entanto, para que se atinja eficiência de remoção desejada para atendimento à legislação, especialmente em lixiviados antigos, um pós-tratamento se faz necessário. O emprego de processos oxidativos avançados (POAs) tem mostrado boa eficiência na remoção de cor, destruição de organismos patogênicos e aumento de biodegradabilidade em efluentes recalcitrantes. O objetivo deste trabalho foi avaliar a remoção de cor e desinfecção de lixiviado de aterro sanitário através do emprego de ozônio e peróxido de hidrogênio como agentes oxidantes. Para tanto, foram realizados doze ensaios no sistema POA instalado para tratar lixiviado bruto e tratado por sistema de lagoas. Seis ensaios foram realizados somente com ozônio e os outros seis com ozônio combinado com peróxido de hidrogênio. O sistema POA possuía volume útil de 460L e os ensaios tiveram a duraçãode 96h. A concentração de ozônio (gás) foi de 29 mg/L e a de peróxido de hidrogênio (adicionado em solução líquida) foi de 1000 mg/L no lixiviado. Com a caracterização do lixiviado, verificou-se alta variabilidade das características dos lixiviados gerados no aterro sanitário de São Leopoldo. Portanto, para a discussão dos resultados de remoção de cor, optou-se por dividir os ensaios realizados por grupos, utilizando como critério para a divisão a concentração inicial de cor verdadeira no lixiviado estudado. Embora inicialmente os resultados indiquem uma similiaridade entre os oxidantes testados a análise de variância de dois fatores realizada com medidas repetidas comprovou que houve diferença entre os agentes os oxidantes utilizados na remoção de cor, sendo observado que o peróxido de hidrogênio apresentou melhor desempenho. Foi observado que quanto menor a concentração inicial de cor verdadeira, mais rápida foi sua remoção. Na desinfecção do lixiviado, os ensaios utilizando ozônio e peróxido de hidrogênio apresentaram maiores taxas de inativação de coliformes termotolerantes, sugerindo que o acréscimo do segundo oxidante foi adequada. A turbidez e matéria orgânica presentes no lixiviado não impediram que a desinfecção ocorresse. Todos os ensaios realizados alcançaram mais de 90% de eficiência na remoção de cor verdadeira em 96h de ensaio e mais de 92% de eficiência na eliminação de coliformes termotolerantes em 24h. / Degradation of grounded waste in landfill generates a liquid with high pollution potential characterized by its dark color, high concentration of organic matter and ammonia nitrogen. Landfill leachate may still contain pathogenic microorganisms from wastes contaminated by human excreta, presenting health risk. For treating landfill leachate, biological processes have shown good performance, especially in organic matter removal. However, in order for the removal efficiency to attain local legislation, particularly in older leachate, a post treatment is necessary. Use of advanced oxidation processes has shown efficiency in color removal, destruction of pathogens and increased biodegradability of recalcitrant effluents. The purpose of this study is to evaluate color removal and disinfection of landfill leachate using ozone and hydrogen peroxide as oxidizing agents. Therefore, twelve experiments were performed in AOP system treating raw and treated leachate by pond system. Six tests were conducted with ozone only and six combining ozone and hydrogen peroxide. The POA was operated with volume of 460L and tests were carried out for 96h. The ozone (gas) concentration was 29 mg/L and hydrogen peroxide (liquid solution added) was 1000 mg/L in the leachate. Characterization of landfill leachate generated in São Leopoldo showed high variability. Therefore, to discuss results of color removal, groups of tests were created using like criteria true color concentration. Although attained results indicated similarity between tested oxidants, performed ANOVA two factors with repeated measures showed difference between oxidizing agents used in color removal. Hydrogen peroxide outperformed ozone alone. True color removal occured faster with smaller true color concentrations. The disinfection of the leachate, using ozone combined with hydrogen peroxide showed higher inactivation rates of fecal coliforms. Turbidity and organic matter in the leachate did not prevent the disinfection. All tests reached over 90% efficiency in true color removal at 96h and over 92% efficiency in disinfection within 24h.
|
314 |
Tratamento de lixiviado de aterro sanitário por contactor biológico rotatório (CBR) visando à remoção de nitrogênioKimura, Maura Sayuri Rodri 30 April 2013 (has links)
Submitted by William Justo Figueiro (williamjf) on 2015-07-14T23:05:27Z
No. of bitstreams: 1
03c.pdf: 7786125 bytes, checksum: 1e0da23c7cb679804d62aea58a41732a (MD5) / Made available in DSpace on 2015-07-14T23:05:27Z (GMT). No. of bitstreams: 1
03c.pdf: 7786125 bytes, checksum: 1e0da23c7cb679804d62aea58a41732a (MD5)
Previous issue date: 2013-04-30 / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / O lixiviado gerado nos aterros caracteriza-se por conter altos teores de material orgânico recalcitrante e nutrientes com alto potencial poluidor. Diversas alternativas para o tratamento de lixiviados de aterros sanitários (LAS) têm sido amplamente estudadas obtendo-se bons resultados quanto à remoção de matéria orgânica biodegradável, porém, em sua maioria, não atingem os padrões de lançamento quanto à remoção de nutrientes. Tendo em vista a promoção de um tratamento adequado aos lixiviados e a minimização de impactos ambientais causados por este efluente, este trabalho estudou a aplicação de um contactor biológico rotatório (CBR) de 3 estágios, em escala piloto, para o tratamento de LAS. O objetivo deste trabalho foi avaliar o desempenho do CBR quanto à remoção de nitrogênio e verificar a relação desta com outros parâmetros como o TRH, razão C/N, cargas superficiais aplicadas e remoção dos compostos orgânicos. O sistema experimental foi operado com alimentação continua de lixiviado proveniente do aterro sanitário de São Leopoldo. Não foram realizados ajustes de pH e temperatura. Nas primeiras 8 semanas operou-se o sistema com um TRH de 15 h (fase 1) e nas 8 semanas subsequentes com TRH de 24h (fase 2). Como resultado, observou-se que a oxidação do nitrogênio amoniacal (NA) alcançou 94% na fase 2 de operação sendo este valor significativamente maior do que o da fase 1 onde se obteve cerca de 49% de oxidação do NA. Não foram obtidas boas remoções de orgânicos, porem observou-se uma melhora na remoção de todos os parâmetros na fase 2 de operação. Esta melhora na eficiência do sistema na fase 2 foi atribuída ao aumento de TRH. Quanto à avaliação da nitrificação no sistema, foi possível observar, na fase 2 de operação, o acúmulo de nitrito predominantemente, enquanto a concentração de nitrato no efluente final foi praticamente inexistente variando de 13 a 31 mg/L . Para as condições avaliadas por este estudo, concluiu-se que, o CBR estudado apresenta potencial para realizar a nitrificação e remoção dos compostos nitrogenados presentes no LAS. Entretanto as condições operacionais devem ser reestudadas para permitir a nitrificação total e não apenas a formação de nitrito. Da mesma forma, prover a remoção de compostos orgânicos carbonáceos. O TRH de 24h proporcionou uma melhora nas eficiências de remoção pelo sistema. Porém, para um melhor desempenho do CBR são necessárias investigações quanto aos ajustes nos parâmetros de operação que possibilitem aumentar a eficiência tanto da nitrificação quanto na remoção de matéria orgânica carbonacea. / The leachate generated in landfills is characterized by high levels of recalcitrant organic compounds and nutrients with high polluter potential. Several alternatives for the treatment of landfill leachate (LL) have been widely studied and presented good results regarding the removal of biodegradable organic matter, however, most of these systems do not reach the standards of environmental disposal of nutrients such as nitrogen compounds. Owing to promote an appropriate treatment to the leachate and minimize the environmental impacts caused by this effluent, this work studied the application of a 3 stage rotating biological contactor (RBC) in a pilot scale. The objective of this study was to evaluate the removal of nitrogen and overall performance of the RBC and check the relationship of this removal with other parameters such as the HRT, C/N ratio, ammonium and COD loads and removal of organic compounds. The experimental system was fed continuously with leachate from São Leopoldo landfill. No adjustments of pH and temperature were made. The first 8 weeks the system was operated applying an HRT of 15 h (1st period) and for the 8 subsequent weeks with HRT of 24h (2nd period). As a result, it was observed that the oxidation of ammonium nitrogen reached 94% in the 2nd period of operation which was greater than the 1st period which obtained approximately 49% of ammonium nitrogen oxidation. Low levels of organic compounds removal were obtained, however an improvement was observed in the organics removal efficiency in the 2nd period of operation. This improvement in overall efficiency of the system in the 2nd period was due to the increase of the HRT. Regarding the evaluation of nitrification in the system, in 2nd period of operation was observed the accumulation of nitrite in the system, while the concentration of nitrate in the final effluent was practically non-existent, ranging from 13 to 31 mg/L. For the conditions evaluated in this study, the conclusion was that the experimental RBC has the potential to carry out the nitrification and the removal of nitrogen compounds in the landfill leachate. Meanwhile, the operational conditions must be re-studied to allow the total nitrification and not only the formation of nitrite, as well as provide the removal of carbonaceous organic compounds. The HRT of 24h provided an improvement on removal efficiencies by the system. However, for a better performance of the RBC, investigations are necessary concerning adjustments in the operational parameters that increase efficiency of nitrification and removal of organic matter.
|
315 |
Estudo da tratabilidade de efluente de reator anaeróbio e lixiviado de aterro sanitário utilizando o processo de lodos ativados / Treatability of the anaerobic effluent and landfill leachate using activated sludge processTuretta, Ludimila 14 September 2011 (has links)
Embora em alguns países como os europeus, o aterro sanitário como forma de disposição final de Resíduos Sólidos venha perdendo espaço, entre nós essa técnica é ainda largamente empregada. O lixiviado gerado nos aterros sanitários apresenta grande potencial poluidor, devido à presença de matéria orgânica, rica em substâncias húmicas e matéria inorgânica, representada especialmente pelos cloretos, nitrogênio amoniacal, entre outras substâncias. O presente trabalho visou, em linhas gerais, avaliar três proporções de mistura de lixiviado/efluente anaeróbio e as influências sobre o processo aeróbio (lodos ativados) em escala de bancada. Nessa pesquisa foram realizados ensaios de tratabilidade utilizando as proporções de 0% (controle), 2,5%, 10% e 20 % de lixiviado em relação ao efluente anaeróbio em diferentes condições experimentais. Os resultados mostraram que as proporções de 10% e 20% de lixiviado nas condições experimentais foram prejudiciais ao sistema aeróbio de tratamento. Foram obtidos os melhores resultados em termos de eficiência de remoção de matéria orgânica e nitrogênio amoniacal no reator alimentado com a proporção de 2,5% de lixiviado bruto, alcançando eficiência de remoção de DQO e nitrogênio amoniacal total (NAT) de 57% e 100%, respectivamente. / The use of landfill as a disposal of solid waste has been avoided in some countries, especially in Europe. Nevertheless this technique is still widely used in Brazil. Leachate generated in landfills has great potential as pollutant due to presence of organic matter, humic substances in high concentrations and inorganic matter such as chlorides and ammonia nitrogen. This study aims to broadly assess effects of three levels of mixing of leachate/anaerobic effluent on aerobic process (activated sludge) in bench scale. Treatability tests were performed using proportions of 0% (control), 2.5%, 10% and 20% leachate added to anaerobic effluent under different experimental conditions. Results showed that proportions of 10% and 20% of leached were unfavorable to aerobic system treatment. The higher removal efficiency of organic matter and ammonia nitrogen was obtained in reactor fed with 2.5% of leachate (removal efficiency of COD and total ammonia nitrogen (TAN) were 57% and 100%, respectively).
|
316 |
Estudo da tratabilidade das soluções de lactose com ácidos húmicos e lactose com lixiviado de aterro sanitário por lodos ativados em escala de bancadaCampos, Rafaella 20 March 2013 (has links)
O lixiviado de aterro sanitário é uma água residuária com elevada concentração de DQO, DBO, amônia, traços de metais pesados e substâncias orgânicas dificilmente biodegradáveis, tais como substâncias húmicas e celulósicas (lignina). Dada essas características, torna-se necessário que ele seja recolhido e devidamente tratado para evitar danos ao meio ambiente e à saúde humana. Uma prática que tem sido adotada por alguns municípios brasileiros é o direcionamento do lixiviado para tratamento consorciado em estações de tratamento de esgoto (ETE). No entanto, são poucos os estudos que avaliam a eficácia desse procedimento. Um dos questionamentos sobre o tratamento biológico diz respeito à remoção do material orgânico dificilmente biodegradável, representado principalmente pelas substâncias húmicas e, dentro dessa classe, destaca-se a fração de ácidos húmicos no lixiviado. Nesse contexto, o presente trabalho teve como objetivo verificar a tratabilidade das soluções contendo lactose, lactose com ácidos húmicos, lactose com 2% em volume de lixiviado de aterro sanitário bruto e lactose com 2% em volume de lixiviado pré-tratado por \"air stripping\", quando submetidas ao tratamento biológico em reatores de lodos ativados em escala de bancada. Assim, buscou-se verificar se essa tecnologia de tratamento é capaz de estabilizar, ainda que parcialmente, compostos orgânicos de difícil biodegradação presentes no lixiviado. A quantificação das substâncias de difícil biodegradação antes e após o tratamento foi realizada pelo método tentativo do \"Equivalente em Ácidos Húmicos\" que se encontra em fase de estudo. Os resultados demonstraram que houve uma remoção parcial dessas substâncias. As análises de espectroscopia na região do infravermelho indicaram que não ocorreu a adsorção dos ácidos húmicos no lodo, o que pode ser uma evidencia de que a redução da concentração dessas substâncias é de fato devida ao seu consumo e não pela precipitação no lodo. Além disso, a adição de 2% em volume do lixiviado não ocasionou redução da população de microrganismos no sistema. / Leachate from sanitary landfills is a type of effluent with high concentrations of COD, BOD, ammonia, heavy metal traces and hardly biodegradable organic compounds such as humic and cellulosic substances (lignin). Thus this effluent needs to be collected and treated in order to prevent damages to the environment and to human health. A common practice in Brazilian cities is to destine the leachate to a sewage treatment plant (STP). However, there are few studies that assess the efficiency of this procedure. One of the questions regarding the biological treatment concerns its efficiency in removing hardly biodegradable organic compounds, represented in the most part by the humic substances, given the high levels of humic acid in the leachate. Within this context, the present study had the objective to verify the treatability of solutions containing lactose, lactose with humic acids, lactose with 2% (in volume) of untreated sanitary landfill leachate, and lactose with 2% of leachate pre-treated by air stripping, submitted to biological treatment in laboratory-scale activated sludge reactors. Thus this paper assessed if such treatment technology can stabilize, even if only partially, the hardly biodegradable organic compounds found in leachate. The quantification of these substances prior to and after treatment was made by using a tentative method called Humic Acids Equivalent, which is still in the phase of studies. The results show that there was a partial removal of these substances. The spectroscopy analyses on the infrared region indicated that there was no adsorption of humic acids onto the sludge, which evidences that the decrease in the levels of these substances was due to their consumption and not precipitation onto the sludge. Also, the addition of 2% of leachate did not reduce the population of microorganisms in the system.
|
317 |
Avaliação do potencial fisiológico de sementes de rabanete (Raphanus sativus L.) / Evaluation of the physiological potential of radish seeds (Raphanus sativus L.)Virgínia Arantes Ferreira Carpi 12 August 2005 (has links)
A intensificação da produção brasileira tem contribuído para a redução da importação de sementes de hortaliças devido, principalmente, à atuação de empresas multinacionais. O elevado valor comercial e o aumento da utilização de sementes híbridas têm justificado o uso de sementes de qualidade diferenciada, cuja oferta tem sido crescente. Neste contexto, o presente trabalho teve como objetivo estudar a eficiência de diferentes métodos para a avaliação do potencial fisiológico de sementes de rabanete (Raphanus sativus L.), visando à identificação dos mais promissores para a utilização em programas de controle de qualidade. Utilizaram-se lotes de três cultivares de rabanete, a saber: Gigante Siculo (4 lotes), Cometa (3 lotes) e Saxa (2 lotes). A avaliação da viabilidade e do vigor das sementes foi realizada mediante a condução de testes de germinação, primeira contagem de germinação, envelhecimento acelerado, deterioração controlada, condutividade elétrica, lixiviação de potássio e emergência de plântulas, sendo estudadas variações nos procedimentos para condução dos testes de envelhecimento acelerado, deterioração controlada, condutividade elétrica e lixiviação de potássio. Concluiu-se que o teste de envelhecimento acelerado com procedimento tradicional, destacando o binômio temperatura/período de exposição de 41ºC/48 horas, é suficientemente sensível para detectar diferenças entre lotes de sementes de rabanete. Os testes de condutividade elétrica e lixiviação de potássio podem constituir alternativas promissoras para a avaliação do vigor de sementes de rabanete, mas há necessidade de estudos adicionais para determinação dos procedimentos mais adequados para sua condução. / The increase in Brazilian production seeds has contributed to reduce the import of vegetable seeds mainly by international companies. The commercial value and the preferential use of hybrids instead of open pollinated cultivars has justified the demand for high quality seeds. In this context, this research was conducted with the objective to study the efficacy of different methods to evaluate the physiological potential of radish (Raphanus sativus L.) seeds. Three cultivars were evaluated: Siculo Giant (four lots), Comet (three lots) and Saxa (two lots). Seed viability and vigor seed lots were determined by germination, germination first count, accelerated aging, controlled deterioration, electrical conductivity, potassium leachate and seedling emergence tests, including alternative procedures for the accelerated aging, controlled deterioration, electrical conductivity and potassium leachate tests. It was concluded that traditional accelerated aging (48 hours/41ºC, was sensitive to identify different levels of physiological potential in the studied lots. The electrical conductivity and potassium leachate are promising options for vigor testing of radish seeds, but research is still necessary to define the most effective procedures to perform these tests.
|
318 |
AvaliaÃÃo de Sistemas de PÃs-Tratamento de Lixiviados por Processos BiolÃgicos e Oxidativos AvanÃados e o Desenvolvimento AnalÃtico para DetecÃÃo e QuantificaÃÃo de Compostos RecalcitrantesElisÃngela Maria Rodrigues Rocha 27 April 2010 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Este trabalho avaliou a viabilidade dos processos biolÃgicos aerÃbios e oxidativos avanÃados (POAs) como pÃs-tratamento de lixiviados antigos provenientes de lagoas de estabilizaÃÃo em sÃrie. Paralelamente, desenvolveu-se uma metodologia analÃtica para detecÃÃo e quantificaÃÃo de compostos aromÃticos, organoclorados, Ãsteres ftalatos e hormÃnios, considerados como compostos recalcitrantes e raramente investigados em lixiviados tratados, principalmente nas ETEs localizadas no estado do CearÃ. Inicialmente foi realizada uma caracterizaÃÃo fÃsico-quÃmica e especiaÃÃo de metais sendo verificado que DQO e amÃnia estavam acima dos limites permitidos pelas normas ambientais, bem como alguns metais. No desenvolvimento da metodologia analÃtica para detecÃÃo e quantificaÃÃo por GC/FID verificou-se que a extraÃÃo em fase sÃlida empregando C-18 foi a melhor tÃcnica para extraÃÃo e prÃ-concentraÃÃo dos compostos recalcitrantes e que os melhores resultados de recuperaÃÃo dos compostos foram obtidos para os compostos aromÃticos e Ãsteres ftalatos. Nos experimentos de pÃs-tratamento empregando os reatores biolÃgicos, reator aerado submerso (RAS) e reator em batelada seqÃencial (RBS), todos foram eficientes na nitrificaÃÃo do lixiviado com percentuais superiores a 90% de remoÃÃo da amÃnia, contudo, nÃo foram eficazes na remoÃÃo de fÃsforo. Em termos de remoÃÃo dos compostos recalcitrantes, o RBS apresentou melhores resultados em relaÃÃo ao RAS para os compostos aromÃticos e Ãsteres ftalatos. No processo de oxidaÃÃo avanÃada UV/H2O2 foi obtida remoÃÃes de DQO, turbidez e descoloraÃÃo da amostra superior a 90%, a partir de 120 minutos de reaÃÃo, em sistema de batelada com recirculaÃÃo. O sistema UV/H2O2 foi eficiente na remoÃÃo dos compostos aromÃticos e, eficaz para os Ãsteres ftalatos benzil-butilftalato (BBP) e dietil-hexilftalato (DEHP) com 100% de remoÃÃo. O processo foto-Fenton com radiaÃÃo solar estudado com o lixiviado de Portugal apresentou-se como uma excelente opÃÃo no pÃs-tratamento do lixiviado em relaÃÃo aos outros sistemas estudados (UV/H2O2 e TiO2/UV) devido a mineralizaÃÃo dos compostos orgÃnicos terem sido de aproximadamente 80% de remoÃÃo do carbono orgÃnico dissolvido (COD), reduÃÃo da aromaticidade e descoloraÃÃo, alÃm de aumentar a biodegradabilidade do lixiviado. A concentraÃÃo Ãtima de ferro para o lixiviado estudado foi de 60 mg L-1 Fe+2, com consumo de H2O2 de 310, 6 mM e aproximadamente 110 kJ L-1 de energia acumulada., mas nÃo foi eficiente na remoÃÃo do Ãster dietil-hexil ftalato (DEHP), um dos principais ftalatos considerado como interferente endÃcrino. Os processos UV/H2O2 e TiO2/UV utilizando energia solar nÃo foram favorÃveis devido a reaÃÃo ser mais lenta em comparaÃÃo com o processo foto-Fenton e terem sido obtidos baixos valores de remoÃÃo de COD, indicando baixa mineralizaÃÃo dos compostos orgÃnicos presentes no lixiviado. / This work assessed the feasibility of using biological and advanced oxidation processes (AOP) as post-treatments for old leachate from stabilization ponds in series. Additionally, an analytical methodology for detection and quantification of aromatic compounds, organochlorides, phthalate esters and hormones, was developed. These compounds are considered as recalcitrant and rarely investigated in treated leachates, mainly in wastewater treatment plants located in the state of CearÃ. Initially, a physico-chemical characterization and a metal speciation was carried out, from which it was verified that COD and ammonia were above the limits permitted by environmental legislation, and also some metals. In the development of the analytical methodology for detection and quantification by GC/FID, the solid phase extraction using C-18 was the best technique for extraction and pre-concentration of the recalcitrant compounds and the best results in terms of recuperation were achieved for the aromatic compounds and phthalate esters. In the post-treatment experiments using biological reactors, aerated submerged reactor (ASR) and sequential batch reactor (SBR), both were efficient in the leachate nitrification reaching ammonia removal efficiencies above 90%. However, they were not efficient on phosphorus removal. In terms of recalcitrant compounds removal, SBR presented better results when compared with ASR for the aromatic compounds and phthalate esters. The advanced oxidation process UV/H2O2 reached turbidity and COD removal and decolourisation efficiencies above 90% from a reaction time of 120 minutes by using recirculation batch mode. The UV/H2O2 system was efficient in the removal of aromatic compounds and the phthalate esters benzyl butyl phthalate (BBP) and diethyl hexyl phthalate (DEHP), achieving 100% removal. The photo-Fenton process with solar radiation assessed with the leachate from Portugal showed to be an excellent option for the leachate post-treatment when compared to the other systems studied (UV/H2O2 and TiO2/UV). Mineralization of organic compounds has reached approximately 80% reduction of dissolved organic carbon (DOC), beside aromaticity and decolourisation reductions and increasing leachate biodegradability. The optimal iron concentration for the leachate studied was 60 mg L-1 Fe+2, with H2O2 consumption of 310.6 mM and approximately 110 kJ L-1 of accumulated energy. However, it was not efficient in the removal the ester DEHP, one of most important phthalates, which is considered an endocrine disruptor. The UV/H2O2 and TiO2/UV processes using solar energy were slower than the photo-Fenton process and low COD removals were achieved, which indicated low mineralization of the organic compounds present in the leachate.
|
319 |
Estratégias de tratamento de lixiviado de aterro sanitário com foco na matéria orgânica biodegradável e nitrogênio amoniacal / Strategies of landfill leachate treatment focused on biodegradable organic matter and ammonia nitrogenVitor Cano 03 September 2014 (has links)
Introdução sistemas de tratamento de esgotos, quando aplicados ao tratamento de lixiviado de aterro sanitário, não têm apresentado bons resultados. Por conta disso, faz-se necessário o desenvolvimento de alternativas para o tratamento de lixiviado. Objetivo avaliar o pós-tratamento de lixiviado de aterro sanitário por wetland construído de fluxo subsuperficial horizontal e reator biológico de leito móvel (RBLM). Materiais e métodos foram realizados dois experimentos com tratamento de lixiviado após remoção de amônia por dessorção. No experimento 1 utilizou-se wetlands construídos de fluxo horizontal em escala de bancada (volume total de 30,8 L), plantados com Cyperus papyrus, Heliconia psittacorum e Gynerium sagittatum, e um controle sem vegetação, preenchidos com pedrisco calcário. O sistema foi alimentado com lixiviado diluído em água em diferentes proporções (entre 10 por cento e 30 por cento ) com concentração média de DQO entre 336 e 750 mg.L-1 e nitrogênio amoniacal (N-NH4) entre 47 e 199 mg.L-1. A operação ocorreu em três etapas: (1ª) alimentação contínua e TDH médio entre 2,7 e 5,3 d; (2ª) regime de ciclos de recirculação do efluente, para avaliar o efeito do aumento de TDH para 21 dias; (3ª) alimentação contínua de duas unidades wetlands em série, visando elevar o TDH (entre 8,1 e 9,9 d) sem recirculação. O experimento 2 foi implantado em escala piloto, com uma unidade de dessorção de amônia seguida de um Reator Biológico de Leito Móvel (RBLM) e um biofiltro anóxico. O RBLM (volume efetivo de 380 L) foi preenchido em 50 por cento com anel pall. Resultados e discussão No experimento 1, obteve-se baixa remoção de DQO com médias inferiores a 40 por cento e concentração final entre 270 e 750 mg.L-1. No entanto, verificou-se remoção de N-NH4, principalmente na 2ª e 3ª etapas, com médias de remoção entre 43 por cento e 81 por cento , resultando em concentração de 20 a 223 mg.L-1, com influência do TDH. No experimento 2, problemas técnicos durante a instalação e operação inicial e interdição do campus da USP-Leste prejudicaram a adaptação do reator e impediram o seu monitoramento por tempo suficiente para geração de dados consistentes, sendo interrompido na fase inicial. Conclusões A baixa eficiência para DQO provavelmente está relacionada à recalcitrância do lixiviado, ou devido à inibição dos microrganismos por toxicidade. Quanto ao N-NH4, infere-se que o aumento do TDH proporcionou maior tempo de difusão de oxigênio para o sistema wetland, suprindo a demanda das bactérias heterotróficas, o que possibilitou utilização do oxigênio excedente pelas nitrificantes, culminando na oxidação do N-NH4. / Introduction sewage treatment systems, when applied to the treatment of landfill leachate, have not shown good results. Thus it is necessary to develop alternatives for the treatment of leachate. Objective To assess the post-treatment of landfill leachate by horizontal subsurface flow constructed wetland and moving bed biofilm reactor (MBBR). Materials and methods Two experiments were conducted with treatment of the leachate after removal of ammonia by stripping. In experiment 1, horizontal flow constructed wetlands, at bench scale (total volume of 30.8 L), planted with Cyperus papyrus, Heliconia psittacorum and Gynerium sagittatum, and a control without vegetation, were filled with calcareous gravel. The system was fed with leachate diluted in water with different proportions (between 10 per cent and 30 per cent ) with mean COD concentration of between 336 and 750 mg.L-1 and ammonia nitrogen (NH4-N) between 47 and 199 mg L-1. The operation was divided in three stages: (1st) continuous feeding with mean HRT between 2.7 and 5.3 d; (2nd) regime of effluent recirculation to evaluate the effect of increasing the HRT to 21 days; (3rd) continuous feeding with two wetlands units in series, aimed HRT increasing (between 8.1 and 9.9 d) without recirculation. Experiment 2 was implemented on a pilot scale, with a unit of ammonia stripping followed by MBBR and an anoxic biofilter. The MBBR (380 L working volume) was filled 50 per cent with pall ring. Results and discussion In experiment 1, the COD removal was low, with averages below 40 per cent , with effluent concentration between 270 and 750 mg.L-1. However, there was removal of NH4-N, especially in the 2nd and 3rd stages, with average removal between 43 per cent and 81 per cent , resulting in concentration between 20 and 223 mg.L-1, with HRT influence. In experiment 2, technical problems during the installation and initial operation and interdiction of the campus of USP-Leste disrupted the reactor acclimation and precluded the monitoring for sufficient time to generate consistent data for discussion. Conclusions The low efficiency for COD is probably related to the recalcitrance of the leachate, or due to inhibition of microorganisms by toxicity. For NH4-N, it is inferred that the increase of the HRT provided greater time for diffusion of oxygen to the wetland system, meeting the demand of heterotrophic bacteria, which allowed the use of excess oxygen by nitrifiers, culminating in the oxidation of NH4-N.
|
320 |
Estudo da fotocatálise heterogênea utilizando luz solar e ZnO como pré-tratamento de percolado de aterro sanitário / Study of application of ZnO using solar photoirradiation as pre-treatment of landfill leachateBruno Leandro Cortez de Souza 31 October 2014 (has links)
O grande impacto ambiental causado pelo chorume proveniente de aterros sanitários impulsiona as pesquisas para o seu tratamento, com o objetivo de se obter a máxima degradação possível dos seus contaminantes recalcitrantes e tóxicos, diminuindo-se assim a sua toxicidade. O desenvolvimento de uma tecnologia eficiente e econômica para o tratamento é indispensável devido ao grande volume gerado e à legislação ambiental cada vez mais restritiva. Desta forma, os Processos Oxidativos Avançados (POAs) são avaliados como uma estratégia para o pré-tratamento, com um alto poder de degradação não seletivo e relação custo-benefício vantajosa. Dos diversos tipos de POAs existentes, aqueles que utilizam semicondutores para a fotocatálise heterogênea e luz solar como fonte de irradiação são os de maior interesse, devido a sua relativa eficiência, estabilidade fotoquímica, natureza não tóxica e baixo custo. Este estudo consistiu em avaliar o nível de degradação do chorume proveniente do aterro sanitário de Cachoeira Paulista - SP, utilizando como catalisador o ZnO irradiado pela luz solar, que possui um vasto espectro de fotoativação aliado ao seu baixo custo. As variáveis de entrada em dois níveis, foram o pH, o tempo de reação, a espessura da camada de ZnO impregnada sobre uma placa metálica e a concentração do efluente. Como variável resposta os valores de concentração expressa em Carbono Orgânico Total (COT) foi a mais adequada. O planejamento de experimentos utilizado foi o fatorial 23 com duplicata no ponto central. Na etapa delineatória, reduções de 28 % de COT foram alcançadas. A utilização da fotocatálise heterogênea utilizando ZnO fotoirradiado com luz solar se mostrou promissora para ser utilizada como um pré-tratamento do chorume. / The major environmental impact of leachate from landfills drives research to treat it, and aims to obtain the maximum degradation of their recalcitrant and toxic contaminants. The development of an efficient and economical treatment technology is indispensable due to the large volume generated and the increasingly restrictive environmental legislation. Thus, Advanced Oxidation Processes (AOPs) are evaluated as a strategy to pre-treatment with a high power non-selective degradation and advantageous cost-benefit ratio. From various types of POAs, those which use the heterogeneous photocatalytic semiconductor and solar light as the source of irradiation are the most interesting, because of its relative efficiency, photochemical stability, low cost and non-toxic nature. This study have assessed the level of degradation of the leachate from the landfill of Cachoeira Paulista - SP, using ZnO irradiated by sunlight as catalyst, which has a wide spectrum of photoactivation combined with its low cost. The input variables on two levels, were pH, reaction time, the thickness of the ZnO layer impregnated on a metal plate and concentration of the effluent. The most appropriate output variable was concentration, expressed in means of Total Organic Carbon (TOC). For the photocatalytic process, a factorial design (23) was used for the design of experiments. In final stage, reductions of 28% TOC were achieved. The use of heterogeneous photocatalysis using solar photoirradiated ZnO seems to be a great alternative as a pre-treatment of leachate.
|
Page generated in 0.0472 seconds