• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 60
  • 43
  • 11
  • 11
  • 9
  • 8
  • 7
  • 4
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 179
  • 179
  • 46
  • 37
  • 32
  • 27
  • 24
  • 24
  • 24
  • 23
  • 21
  • 20
  • 15
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Chemical process analysis: chemometrics; instrument control; applications in equilibrium and kinetic investigations

Norman, Sarah Elizabeth January 2008 (has links)
Research Doctorate - Doctor of Philosophy (PhD) / This work presents the development and application of modern data acquisition and analysis techniques for the investigations of equilibrium and kinetic reactions. The analytical technique is known as second order global analysis and a background of this relatively novel approach has been given. The theory behind and characteristics of the computer programs developed analysis as part of this research are described in Chapter Two along with descriptions of the instrumentation and programs developed for the acquisition of both potentiometric and spectrophotometric data. Applications of the developed programs include a potentiometric and spectrophotometric study of the protonation and stability equilibria of a series of polydentate N-donor ligands, as detailed in Chapter Three. The combination of potentiometric and spectrophotometric analysis has been shown to be a powerful analytical tool. Spectrophotometric titrations were also combined with fast stop-flow experiments in order to elucidate the complex reaction mechanisms associated with helicating ligands. The helication of the ligand ‘PepdaH₂’ with copper(II) and nickel(II) is examined in Chapter Four, along with discussions concerning the ability to induce chirality in the helicates from the addition of a chiral counter ion. Investigations into chirality were further continued in Chapter Five where the stereoselectivity of a benzimidazole-based ligand was investigated with circular dichroism titrations. The synthesis and characterisation of the benzimidazole-based ligands are provided, including a study of the ability of the ligands to form higher order complexes as investigated using electrospray mass spectroscopy. Chapter Six provides an in-depth discussion concerning the use of combined glass hydrogen selective electrodes for the determination of equilibrium constants, as this was a major focus of this research. Different calibration techniques are discussed and a description of the internal calibration technique developed is provided along with examples of the advantages of performing internal calibration of the electrode.
62

Modelagem e investigação numérica de escoamentos de fluidos estruturados tixotrópicos

Fonseca, Cleiton Elsner da January 2013 (has links)
Fluidos Não-newtonianos estão presentes em grande quantidade na natureza e em muitas aplicações industriais. Tais fluidos apresentam uma variedade de comportamentos específicos. Dentre eles podemos citar: elasticidade, plasticidade, viscosidade variando com a taxa de deformação, tixotropia. Esta tese de doutorado apresenta um recente modelo para Fluidos Estruturados Tixotrópicos (de Souza Mendes, 2009), no qual baseasse nas tradicionais equações de balanço de momentum e massa, em uma equação constitutiva de Maxwell-b modificada e uma equação de evolução para o nível de estrutura do material. Na equação constitutiva de Maxwell-b modificada, tempo de relaxação e viscosidade estrutural são funções da estrutura do material. A equação evolutiva para o parâmetro de estruturação prevê efeitos de tixotropia, dependentes do tempo de equilíbrio do material. As equações que constituem o modelo mecânico para Fluidos Estruturados Tixotrópicos são aproximadas numericamente através do Método de Elementos Finitos de Galerkin Mínimos-quadrados (GLS). Tal método adicionou termos dependentes de malha ao método clássico de Galerkin, de forma a aumentar a estabilidade da formulação original, proporcionando compatibilizar os sub-espaços de velocidade e pressão. São investigados escoamentos creeping flow de Fluidos Estruturados Tixotrópicos em dois problemas clássicos de engenharia: em torno de um cilindro confinado entre duas placas e em uma expansão planar abrupta. Parâmetros relevantes ao modelo são variados em faixas pertinentes ao problema físico simulado e os resultados demonstraram uma boa capacidade de previsão. / Non-Newtonian fluids are present in large quantities in nature and in many industrial applications. Such fluids exhibit a variety of specific behaviors. Among them we can mention: elasticity, plasticity, viscosity varying with the strain rate, thixotropy, etc. This thesis presents a new model for thixotropic Structured Fluids (de Souza Mendes, 2009), in which were a basis in traditional balance equations of mass and momentum, the constitutive equation of Maxwell-type and an evolution equation for the level structure of the material. In the modified constitutive equation of Maxwell-b, relaxation time and structural viscosity are functions of material structure. The structure parameter evolutive equation provides effects of thixotropy, dependent on the equilibration time of the material. The equations which constitute the mechanical model for Structured Thixotropic fluids are approximated numerically using the Galerkin Least-squares Finite Element Method (GLS). Such a method added mesh dependent terms to the classical method of Galerkin in order to increase the stability of the original formulation, providing compatibility between sub-spaces of velocity and pressure. Are investigated Structured Thixotropic Fluids creeping flow in two classical problems in engineering: around a cylinder confined between two plates and in a planar abrupt expansion. Relevant parameters to the model are varied in pertinent ranges to physical problem simulated and the results demonstrated a good predictive capability.
63

Caracterização de bebidas à base de soja empregando espectroscopia no infravermelho médio com transformada de Fourier por reflexão total atenuada e quimiometria

Rech, André Machado January 2018 (has links)
Neste trabalho, foram estudadas estratégias para caracterização de bebidas à base de soja (BBS), por meio de análises por espectroscopia no infravermelho médio com transformada de Fourier com acessório de reflexão total atenuada (FTIR-ATR). Foram utilizadas 20 amostras comerciais de BBS, de 7 diferentes sabores e 3 diferentes marcas. Os teores estudados nas BBS foram glicídios totais, glicídios redutores, glicídios não redutores, e proteínas totais. Os modelos de regressão multivariada foram construídos por mínimos quadrados parciais (PLS), empregando como seleção de variáveis os métodos de mínimos quadrados parciais por intervalo (iPLS) e mínimos quadrados parciais por sinergismo de intervalos (siPLS). As seleções de variáveis por siPLS apresentaram os melhores resultados para os modelos construídos. Entre as propriedades avaliadas, a de glicídios totais apresentou modelos com erros de calibração e previsão (RMSECV e RMSEP) baixos, e coeficientes de determinação (R2cv e R2prev) próximos de um. Para proteínas totais, os modelos apresentaram resultados promissores, pois também tiveram erros de calibração e previsão (RMSECV e RMSEP) baixos, e coeficientes de determinação (R2cv e R2prev) próximos de um, considerando-se que as amostras reais e não apresentavam uma variabilidade de concentração de proteínas ideal. Para as propriedades de glicídios redutores e glicídios não redutores, não foram obtidos bons resultados para os modelos de regressão. Desta forma, a metodologia proposta apresenta potencial em análises de rotinas para determinação simultânea de glicídios totais e proteínas, atendendo aos requisitos referente às informações nutricionais na rotulagem das BBS, somando-se às vantagens da espectroscopia no infravermelho, tais como rapidez na análise, elevada frequência analítica, pequena quantidade de amostra necessária, baixo custo, não ser destrutiva e ser ambientalmente amigável. / In this work, strategies were studied for the characterization of soy-based beverages (SBB), by means of Fourier transform infrared spectroscopy with attenuated total reflectance (FTIR-ATR). Twenty commercial samples of SBB were used, of 7 different flavors and 7 different brands. The contents studied in SBB were total sugar, reducing sugar, non-reducing sugars, and total proteins. The multivariate regression models were constructed by partial least squares (PLS), with evaluation of the methods by interval partial least squares (iPLS) and by sinergy interval partial least squares (siPLS), for selection of variables. The selections of variables per siPLS presented the best results for the constructed models. Among the evaluated properties, the total sugar content presented models with low calibration and prediction errors (RMSECV and RMSEP), and determination coefficients (R2cv and R2prev) close to one. For total proteins, the models presented promising results, as they also had low calibration and prediction errors (RMSECV and RMSEP), and determination coefficients (R2cv and R2prev) close to one, considering that the actual samples did not present an ideal protein concentration variability. For the properties of reducing sugars and non-reducing sugars, good results were not obtained for the regression models. In this way, the proposed methodology presents potential in routine analysis for simultaneous determination of total glycogen and protein, taking into account the requirements referring to the nutritional information in the SBB labeling, adding to the advantages of the infrared spectroscopy, such as speed in the analysis, high analytical frequency, small amount of sample required, low cost, non destructive and environmentally friendly.
64

Localização de faltas de alta impedância : formulação baseada na impedância aparente e no método de mínimos quadrados

Ferraz, Renato Gonçalves January 2014 (has links)
As linhas de transmissão são usadas para transmitir energia elétrica por longas distâncias e estão naturalmente expostas a condições climáticas severas e à ocorrência de faltas, especialmente as linhas aéreas. Estatísticas mostram que entre 70% - 90% das faltas em linhas de transmissão aéreas são momentâneas (ou transitórias) e apresentam formação de arco elétrico. O arco elétrico é a principal característica de uma falta de alta impedância e resulta do pobre contato entre um condutor energizado e a superfície envolvida. Esta tese aborda o problema de localização de faltas de alta impedância em linhas de transmissão curtas. Propõese uma nova técnica de localização de faltas de alta impedância baseada na impedância aparente, desenvolvida no domínio da frequência e que utiliza componentes de fase. A estimativa da distância da falta é obtida a partir da solução de um sistema sobredeterminado de equações lineares, obtida pela aplicação do método de mínimos quadrados. A abordagem proposta permite estimar a distância de faltas de alta impedância momentâneas e permanentes, em linhas de transmissão curtas simples e paralelas, transpostas ou não. O desempenho da técnica de localização de faltas proposta é avaliado mediante estudos de casos simulados no Alternative Transients Program (ATP) considerando análises de sensibilidade e comparativa, bem como casos reais de faltas. Os resultados obtidos, considerando faltas de alta impedância simuladas e reais, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas em linhas de transmissão curtas em decorrência do desempenho demonstrado e, também, por características tais como: formulação simplificada no domínio da frequência, simplicidade e facilidade de implementação em dispositivos reais e aplicabilidade a casos reais. / Transmission lines are used to transmit electric power over long distances and are naturally exposed to severe weather conditions, especially overhead lines. Such conditions are highly favorable to the occurrence of faults. Statistics show that between 70% - 90% of faults on overhead lines are nonpermanent (or transient), and present arcing. Arcing is the main characteristic of a nonlinear high impedance fault and is the result of poor contact between an energized conductor and the ground or a grounded object. This thesis approaches the high impedance fault location on short transmission lines problem. It is proposed an impedancebased nonlinear high impedance fault location formulation developed in frequency domain and phase components. The formulation uses the least square method and synchronized phasors, measured by, for example, digital fault recorders installed at both line terminals. The proposed approach allows to estimate the distance of high impedance momentary and permanent faults on short transposed or untransposed transmission lines. The performance of the proposed fault location approach is evaluated through analysis of simulated cases in the Alternative Transients Program (ATP) considering sensitivity and comparative analyzes, and actual cases of high impedance faults. The results, considering simulations of high impedance faults and actual cases, indicate clearly that the proposed approach is valid as fault location technique in short transmission lines due to the demonstrated performance.
65

Modelagem e investigação numérica de escoamentos de fluidos estruturados tixotrópicos

Fonseca, Cleiton Elsner da January 2013 (has links)
Fluidos Não-newtonianos estão presentes em grande quantidade na natureza e em muitas aplicações industriais. Tais fluidos apresentam uma variedade de comportamentos específicos. Dentre eles podemos citar: elasticidade, plasticidade, viscosidade variando com a taxa de deformação, tixotropia. Esta tese de doutorado apresenta um recente modelo para Fluidos Estruturados Tixotrópicos (de Souza Mendes, 2009), no qual baseasse nas tradicionais equações de balanço de momentum e massa, em uma equação constitutiva de Maxwell-b modificada e uma equação de evolução para o nível de estrutura do material. Na equação constitutiva de Maxwell-b modificada, tempo de relaxação e viscosidade estrutural são funções da estrutura do material. A equação evolutiva para o parâmetro de estruturação prevê efeitos de tixotropia, dependentes do tempo de equilíbrio do material. As equações que constituem o modelo mecânico para Fluidos Estruturados Tixotrópicos são aproximadas numericamente através do Método de Elementos Finitos de Galerkin Mínimos-quadrados (GLS). Tal método adicionou termos dependentes de malha ao método clássico de Galerkin, de forma a aumentar a estabilidade da formulação original, proporcionando compatibilizar os sub-espaços de velocidade e pressão. São investigados escoamentos creeping flow de Fluidos Estruturados Tixotrópicos em dois problemas clássicos de engenharia: em torno de um cilindro confinado entre duas placas e em uma expansão planar abrupta. Parâmetros relevantes ao modelo são variados em faixas pertinentes ao problema físico simulado e os resultados demonstraram uma boa capacidade de previsão. / Non-Newtonian fluids are present in large quantities in nature and in many industrial applications. Such fluids exhibit a variety of specific behaviors. Among them we can mention: elasticity, plasticity, viscosity varying with the strain rate, thixotropy, etc. This thesis presents a new model for thixotropic Structured Fluids (de Souza Mendes, 2009), in which were a basis in traditional balance equations of mass and momentum, the constitutive equation of Maxwell-type and an evolution equation for the level structure of the material. In the modified constitutive equation of Maxwell-b, relaxation time and structural viscosity are functions of material structure. The structure parameter evolutive equation provides effects of thixotropy, dependent on the equilibration time of the material. The equations which constitute the mechanical model for Structured Thixotropic fluids are approximated numerically using the Galerkin Least-squares Finite Element Method (GLS). Such a method added mesh dependent terms to the classical method of Galerkin in order to increase the stability of the original formulation, providing compatibility between sub-spaces of velocity and pressure. Are investigated Structured Thixotropic Fluids creeping flow in two classical problems in engineering: around a cylinder confined between two plates and in a planar abrupt expansion. Relevant parameters to the model are varied in pertinent ranges to physical problem simulated and the results demonstrated a good predictive capability.
66

Caracterização de bebidas à base de soja empregando espectroscopia no infravermelho médio com transformada de Fourier por reflexão total atenuada e quimiometria

Rech, André Machado January 2018 (has links)
Neste trabalho, foram estudadas estratégias para caracterização de bebidas à base de soja (BBS), por meio de análises por espectroscopia no infravermelho médio com transformada de Fourier com acessório de reflexão total atenuada (FTIR-ATR). Foram utilizadas 20 amostras comerciais de BBS, de 7 diferentes sabores e 3 diferentes marcas. Os teores estudados nas BBS foram glicídios totais, glicídios redutores, glicídios não redutores, e proteínas totais. Os modelos de regressão multivariada foram construídos por mínimos quadrados parciais (PLS), empregando como seleção de variáveis os métodos de mínimos quadrados parciais por intervalo (iPLS) e mínimos quadrados parciais por sinergismo de intervalos (siPLS). As seleções de variáveis por siPLS apresentaram os melhores resultados para os modelos construídos. Entre as propriedades avaliadas, a de glicídios totais apresentou modelos com erros de calibração e previsão (RMSECV e RMSEP) baixos, e coeficientes de determinação (R2cv e R2prev) próximos de um. Para proteínas totais, os modelos apresentaram resultados promissores, pois também tiveram erros de calibração e previsão (RMSECV e RMSEP) baixos, e coeficientes de determinação (R2cv e R2prev) próximos de um, considerando-se que as amostras reais e não apresentavam uma variabilidade de concentração de proteínas ideal. Para as propriedades de glicídios redutores e glicídios não redutores, não foram obtidos bons resultados para os modelos de regressão. Desta forma, a metodologia proposta apresenta potencial em análises de rotinas para determinação simultânea de glicídios totais e proteínas, atendendo aos requisitos referente às informações nutricionais na rotulagem das BBS, somando-se às vantagens da espectroscopia no infravermelho, tais como rapidez na análise, elevada frequência analítica, pequena quantidade de amostra necessária, baixo custo, não ser destrutiva e ser ambientalmente amigável. / In this work, strategies were studied for the characterization of soy-based beverages (SBB), by means of Fourier transform infrared spectroscopy with attenuated total reflectance (FTIR-ATR). Twenty commercial samples of SBB were used, of 7 different flavors and 7 different brands. The contents studied in SBB were total sugar, reducing sugar, non-reducing sugars, and total proteins. The multivariate regression models were constructed by partial least squares (PLS), with evaluation of the methods by interval partial least squares (iPLS) and by sinergy interval partial least squares (siPLS), for selection of variables. The selections of variables per siPLS presented the best results for the constructed models. Among the evaluated properties, the total sugar content presented models with low calibration and prediction errors (RMSECV and RMSEP), and determination coefficients (R2cv and R2prev) close to one. For total proteins, the models presented promising results, as they also had low calibration and prediction errors (RMSECV and RMSEP), and determination coefficients (R2cv and R2prev) close to one, considering that the actual samples did not present an ideal protein concentration variability. For the properties of reducing sugars and non-reducing sugars, good results were not obtained for the regression models. In this way, the proposed methodology presents potential in routine analysis for simultaneous determination of total glycogen and protein, taking into account the requirements referring to the nutritional information in the SBB labeling, adding to the advantages of the infrared spectroscopy, such as speed in the analysis, high analytical frequency, small amount of sample required, low cost, non destructive and environmentally friendly.
67

Restrições ao crédito e o uso dos recursos financeiros nas empresas brasileiras

Peres, Ariádine January 2014 (has links)
Este estudo têm como objetivo identificar qual o comportamento de empresas brasileiras de capital aberto com relação à aplicação dos recursos financeiros de seus fluxos de caixa (recursos internos) em investimentos e não investimentos (em fins que não se configuram como um projeto real de investimento) no curto e longo prazo e mostrar como essa questão está relacionado com o grau de restrições financeiras enfrentado pelas empresas. Para alcançar esse objetivo foram estimadas quatro regressões pelo método OLS (Ordinary Least Square / Mínimos Quadrados Ordinários), cada uma delas com uma das variáveis resposta correspondentes aos principais usos de caixa, ou seja, retenção de caixa, investimentos, dividendos e redução do financiamento externo e com as variáveis explicativas dadas pelo fluxo de caixa nos períodos t, t-1 e t-2 e algumas variáveis de controle específicas da firma. Os resultados sugerem que empresas brasileiras restritas e irrestritas se comportam de forma diferente ao receberem um choque positivo em seus fluxos de caixa e que o comportamento das mesmas também difere no curto e no longo prazo. Empresas restritas e irrestritas ao receberem um choque positivo em seus fluxos de caixa, retêm caixa no período contemporâneo e alocam tais recursos intertemporalmente. Empresas restritas investem mais no curto prazo enquanto as irrestritas investem mais no longo prazo. No curto prazo, empresas irrestritas distribuem mais dividendos do que empresas irrestritas e no longo prazo, os coeficientes dos fluxos de caixa não são significativos para nenhum dos grupos. No curto prazo empresas irrestritas reduzem o financiamento externo, enquanto empresas restritas levantam mais financiamentos externos e no longo prazo, esse comportamento se inverte. Dessa forma, fica clara a importância de se considerar o longo prazo bem como as restrições financeiras enfrentadas pelas empresas. / This study aim to identify what is the behaviour of Brazilian public companies regarding the use of financial resources of cash flows (internal resources) in investments and not investments (for purposes that are not configured as a real investment project) in the short and long term and show how this is related to the degree of financial constraints faced by firms. To achieve this aim, four regressions were estimated by OLS ( Ordinary Least Square), each with one of the response variables corresponding to the main uses of cash, ie , cash holding, investments, dividends and external finance reduction and the explanatory variables given by the cash flow in periods t , t - 1 and t - 2 and some control variables specific of the firm. The results suggest that restricted and unrestricted Brazilian companies behave differently when they receive a positive shock on cash flows and their behavior also differs in the short and long term. When constrained and unconstrained firms receive a positive impact on cash flows, they retain cash in the contemporary period and intertemporally allocate such resources. Constrained firms invest more in the short term while the unrestricted invest more in the long run. In the short term, unconstrained firms distribute more dividends than unconstrained firms and in the long run, the coefficients of cash flows are not significant for either groups. In the short term unconstrained firms reduce external finance, while constrained firms raise more external finance and in the long term, this behavior is reversed. Thus, it is clear that it matters to consider the long term as well as financial constraints faced by firms.
68

Localização de faltas de alta impedância : formulação baseada na impedância aparente e no método de mínimos quadrados

Ferraz, Renato Gonçalves January 2014 (has links)
As linhas de transmissão são usadas para transmitir energia elétrica por longas distâncias e estão naturalmente expostas a condições climáticas severas e à ocorrência de faltas, especialmente as linhas aéreas. Estatísticas mostram que entre 70% - 90% das faltas em linhas de transmissão aéreas são momentâneas (ou transitórias) e apresentam formação de arco elétrico. O arco elétrico é a principal característica de uma falta de alta impedância e resulta do pobre contato entre um condutor energizado e a superfície envolvida. Esta tese aborda o problema de localização de faltas de alta impedância em linhas de transmissão curtas. Propõese uma nova técnica de localização de faltas de alta impedância baseada na impedância aparente, desenvolvida no domínio da frequência e que utiliza componentes de fase. A estimativa da distância da falta é obtida a partir da solução de um sistema sobredeterminado de equações lineares, obtida pela aplicação do método de mínimos quadrados. A abordagem proposta permite estimar a distância de faltas de alta impedância momentâneas e permanentes, em linhas de transmissão curtas simples e paralelas, transpostas ou não. O desempenho da técnica de localização de faltas proposta é avaliado mediante estudos de casos simulados no Alternative Transients Program (ATP) considerando análises de sensibilidade e comparativa, bem como casos reais de faltas. Os resultados obtidos, considerando faltas de alta impedância simuladas e reais, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas em linhas de transmissão curtas em decorrência do desempenho demonstrado e, também, por características tais como: formulação simplificada no domínio da frequência, simplicidade e facilidade de implementação em dispositivos reais e aplicabilidade a casos reais. / Transmission lines are used to transmit electric power over long distances and are naturally exposed to severe weather conditions, especially overhead lines. Such conditions are highly favorable to the occurrence of faults. Statistics show that between 70% - 90% of faults on overhead lines are nonpermanent (or transient), and present arcing. Arcing is the main characteristic of a nonlinear high impedance fault and is the result of poor contact between an energized conductor and the ground or a grounded object. This thesis approaches the high impedance fault location on short transmission lines problem. It is proposed an impedancebased nonlinear high impedance fault location formulation developed in frequency domain and phase components. The formulation uses the least square method and synchronized phasors, measured by, for example, digital fault recorders installed at both line terminals. The proposed approach allows to estimate the distance of high impedance momentary and permanent faults on short transposed or untransposed transmission lines. The performance of the proposed fault location approach is evaluated through analysis of simulated cases in the Alternative Transients Program (ATP) considering sensitivity and comparative analyzes, and actual cases of high impedance faults. The results, considering simulations of high impedance faults and actual cases, indicate clearly that the proposed approach is valid as fault location technique in short transmission lines due to the demonstrated performance.
69

Influência das irregularidades da forma em peças de madeira na determinação do módulo de elasticidade longitudinal / Influence of timber pieces shape irregularities in longitudinal modulus of elasticity determination

André Luis Christoforo 06 December 2007 (has links)
Atualmente, os documentos normativos que tratam da determinação das propriedades de rigidez e resistência para elementos roliços estruturais de madeira não levam em consideração em seus modelos matemáticos a influência das irregularidades existentes na geometria dessas peças. O presente trabalho tem como objetivo determinar o valor ótimo do módulo de elasticidade longitudinal para peças roliças estruturais de madeira por intermédio de uma técnica de otimização aliada ao método da análise inversa, ao método dos elementos finitos e ao método dos mínimos quadrados. / Currently, the normative documents that deal with the determination of the properties of rigidity and resistance for round structural timber elements round timber do not take in consideration in both calculations and mathematical models the influence of the existing of irregularities in the geometry of these elements. An objective of this work is to determine the optimum value of the modulus of elasticity for round structural timber elements by an optimization technique associated to the inverse analysis method, to the finite element method and the least squares method.
70

Localização de faltas de alta impedância : formulação baseada na impedância aparente e no método de mínimos quadrados

Ferraz, Renato Gonçalves January 2014 (has links)
As linhas de transmissão são usadas para transmitir energia elétrica por longas distâncias e estão naturalmente expostas a condições climáticas severas e à ocorrência de faltas, especialmente as linhas aéreas. Estatísticas mostram que entre 70% - 90% das faltas em linhas de transmissão aéreas são momentâneas (ou transitórias) e apresentam formação de arco elétrico. O arco elétrico é a principal característica de uma falta de alta impedância e resulta do pobre contato entre um condutor energizado e a superfície envolvida. Esta tese aborda o problema de localização de faltas de alta impedância em linhas de transmissão curtas. Propõese uma nova técnica de localização de faltas de alta impedância baseada na impedância aparente, desenvolvida no domínio da frequência e que utiliza componentes de fase. A estimativa da distância da falta é obtida a partir da solução de um sistema sobredeterminado de equações lineares, obtida pela aplicação do método de mínimos quadrados. A abordagem proposta permite estimar a distância de faltas de alta impedância momentâneas e permanentes, em linhas de transmissão curtas simples e paralelas, transpostas ou não. O desempenho da técnica de localização de faltas proposta é avaliado mediante estudos de casos simulados no Alternative Transients Program (ATP) considerando análises de sensibilidade e comparativa, bem como casos reais de faltas. Os resultados obtidos, considerando faltas de alta impedância simuladas e reais, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas em linhas de transmissão curtas em decorrência do desempenho demonstrado e, também, por características tais como: formulação simplificada no domínio da frequência, simplicidade e facilidade de implementação em dispositivos reais e aplicabilidade a casos reais. / Transmission lines are used to transmit electric power over long distances and are naturally exposed to severe weather conditions, especially overhead lines. Such conditions are highly favorable to the occurrence of faults. Statistics show that between 70% - 90% of faults on overhead lines are nonpermanent (or transient), and present arcing. Arcing is the main characteristic of a nonlinear high impedance fault and is the result of poor contact between an energized conductor and the ground or a grounded object. This thesis approaches the high impedance fault location on short transmission lines problem. It is proposed an impedancebased nonlinear high impedance fault location formulation developed in frequency domain and phase components. The formulation uses the least square method and synchronized phasors, measured by, for example, digital fault recorders installed at both line terminals. The proposed approach allows to estimate the distance of high impedance momentary and permanent faults on short transposed or untransposed transmission lines. The performance of the proposed fault location approach is evaluated through analysis of simulated cases in the Alternative Transients Program (ATP) considering sensitivity and comparative analyzes, and actual cases of high impedance faults. The results, considering simulations of high impedance faults and actual cases, indicate clearly that the proposed approach is valid as fault location technique in short transmission lines due to the demonstrated performance.

Page generated in 0.0703 seconds