• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Effect of drug loading and plasticizer on drug release from poly lactic acid film

Mokhtar, Mohamed January 2005 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
2

PLGA implants for ocular drug delivery / Implants à base de PLGA pour la libération oculaire

Bode, Corinna 30 April 2019 (has links)
Jusqu'à aujourd'hui, le traitement des maladies oculaires postérieures, telles que la dégénérescence maculaire liée à l'âge, la rétinopathie diabétique et l'uvéite, reste difficile. L'œil avec ses différentes barrières oculaires est bien protégé des agressions extérieures. Ces barrières réduisent également la biodisponibilité des médicaments pour le vitré. Après une administration topique, seule une quantité limitée (0,001 - 0,0004 %) permet d'atteindre le vitreux. Ceci est causé par exemple par une dilution des larmes et une faible perméabilité cornéenne du médicament. Après une administration systémique ou orale, les barrières hémato-oculaires empêchent le médicament d'entrer et seulement environ 2 % du médicament administré se trouve dans le vitré. Afin d'atteindre des concentrations thérapeutiques, une dose élevée doit être administrée, ce qui augmente le risque d'effets secondaires. La façon la plus efficace de traiter les maladies postérieures restent l'injection intravitréenne. Cependant, de petites molécules lipophiles comme la dexaméthasone peuvent facilement se diffuser à travers la rétine et les barrières oculaires et ont donc une demi-vie limitée de quelques heures seulement. Étant donné que de nombreuses maladies postérieures sont chroniques, une injection intravitréenne fréquente serait nécessaire. Chaque injection comporte des risques de décollement de la rétine, d'hémorragie et d'autres effets secondaires. Les implants biodégradables pour administration intravitréenne peuvent prolonger la libération du médicament et en diminuer les effets secondaires. PLGA est un polymère largement utilisé qui est biocompatible et biodégradable. Il peut également soutenir la libération du médicament de quelques jours à plusieurs mois. Dans cette étude, les implants de formation in situ (ISFI) et les implants préformés préparés par extrusion à chaude ont été étudié en profondeur. L'objectif de ce travail était (i) d'étudier l'impact du volume du rejet (ii) évaluer le comportement de libération, de gonflement et de dégradation des implants préformés préparés avec différentes charges de médicament et différents types de polymères, (iii) visualiser la libération de médicament et l'absorption d'eau des implants préformés et de l'ISFI en utilisant des médicaments modèles colorés et (iv) étudier l'effet des quantités variables des différents additifs sur les caractéristiques essentielles de l'ISFI. Ces informations peuvent aider à fabriquer des implants avec différents profils de libération. Nos études montrent que l'ISFI est assez robuste en ce qui concerne les différents volumes de l'humeur vitreuse que l'on peut rencontrer in vivo. Cependant, le poids moléculaire et la concentration du polymère ont une forte influence sur la morphologie et le gonflement de l'implant. Par conséquent, la dégradation et la libération du médicament sont affectées. Pour les implants préformés, le gonflement "orchestre" la libération du médicament. Au début, seule une quantité limitée d'eau peut se diffuser dans les implants. Ainsi, seules des quantités insignifiantes du médicament sont dissoutes et peuvent être libérées. Lorsque le PLGA commence à se dégrader, le polymère devient plus hydrophile et de plus grandes quantités d'eau peuvent pénétrer. Ce gonflement du polymère facilite la dissolution et la diffusion du médicament et déclenche la libération du médicament. Les études utilisant des médicaments modèles colorés corroborent le rôle de la pénétration de l'eau et de la dissolution du médicament pour les implants préformés. En ce qui concerne l'ISFI, il a visualisé l'importance de la concentration du polymère sur la structure interne de l'implant qui en résulte et par conséquent l'absorption d'eau et la libération du médicament. Le comportement de gonflement et la morphologie de l'ISFI pourraient également être modifiés de manière significative en utilisant différents additifs. L'effet global sur la libération du médicament a été limité. / Until today, the treatment of posterior eye diseases, such as age-related macular degeneration, diabetic retinopathy and uveitis, remains challenging. The eye with its different ocular barriers is well protected from external factors. Those barriers also reduce the bioavailability of drugs to the vitreous. After a topical administration, only a limited amount (0.001 – 0.0004 %) reaches the vitreous. This is caused by for example reflexive blinking, tear dilution and a low corneal permeability of the drug. After a systemic or oral administration, the blood-aqueous and the blood-retinal barrier hinder the drug from entering and only around 2 % of the administered drug is found in the vitreous. In order to reach therapeutic concentrations, a high dose has to be given which in turn increases the risk for systemic side effects. The most efficient way to treat posterior diseases remains the intravitreal injection. However, small lipophilic molecules like dexamethasone can easily diffuse through the retina and the blood-ocular barriers and, thus, have a limited half-life of just a few hours. Since many of the posterior diseases are chronic, a frequent intravitreal injection would be necessary. Every intravitreal injection bears the risks for retinal detachment, hemorrhage, and other side effects. Biodegradable implants for intravi-treal administration can prolong the drug release and in turn decrease the side effects. Poly(lac-tic-co-glycolic acid) (PLGA) is a widely used polymer that is biocompatible and biodegrada-ble. It can also sustain the drug release from a few days up to several months. In this study, in-situ forming implants (ISFI) and pre-formed implants prepared via hot melt extrusion were studied in depth. The aim of this work was (i) to study the impact of the volume of the release medium, polymer type and concentration as well as drug content of different ISFI, (ii) to eval-uate the drug release, swelling and degradation behavior of pre-formed implants prepared with different drug loadings and polymer types, (iii) to visualize the drug release and water uptake of ISFI and pre-formed implants using colored model drugs and (iv) to investigate the effect of varying amounts of different additives on key features of ISFI. This knowledge can help to manufacture implants with different release profiles. Our studies show that ISFI are rather ro-bust regarding different volumes of the vitreous humor that could be encountered in vivo. How-ever, the polymer molecular weight and polymer concentration have a strong influence on the morphology and swelling behavior of the implants. Consequently, the degradation and drug release are affected. For pre-formed implants the swelling “orchestrates” the drug release. In the beginning only limited amounts of water can diffuse into the implants. Thus, only insignif-icant amounts of the drug are dissolved and can be released. When the PLGA starts to degrade, the polymer becomes more hydrophilic and bigger amounts of water can penetrate. This poly-mer swelling facilitates drug dissolution and diffusion and initiates the drug release. The studies using colored model drugs corroborate the role of water penetration and drug dissolution for pre-formed implants. Concerning ISFI, it visualized the importance of the polymer concentra-tion on the resulting inner implant structure and consequently the water uptake and drug release. The swelling behavior and morphology of ISFI could also be significantly altered using differ-ent additives. The overall effect on the drug release was limited.
3

Synthèse et caractérisation des nanoparticules intelligentes / Synthesis and characterization of smart nanoparticles

Jamal Al Dine, Enaam 07 June 2017 (has links)
L’un des enjeux majeurs en nanomédecine est de développer des systèmes capables à la fois de permettre un diagnostic efficace et également de servir de plateforme thérapeutique pour combattre les infections et les neuro-dégénérescences. Dans cette optique, et afin d’améliorer la détection de tumeurs, des agents de contraste ont été développés dans le but d’augmenter le rapport signal sur bruit. Parmi ces agents, les nanoparticules (NPs) d’oxyde de fer superparamagnétiques (SPIOs) et les quantum dots (QDs) sont des candidats idéaux et ont reçu une grande attention depuis une vingtaine d’années. De surcroit, leurs propriétés spécifiques dues à leurs dimensions nanométriques et leurs formes permettent de moduler leur bio-distribution dans l’organisme. L’opportunité de revêtir ces NPs biocompatibles par des couches de polymères devraient permettre d’améliorer la stabilité de ces nanomatériaux dans l’organisme. Et par conséquent, favoriser leur biodistribution et également leur conférer de nouvelles applications en l’occurrence des applications biomédicales. Dans ce travail de thèse, nous avons développé de nouveaux systèmes thermo-répondant basés sur un cœur SPIOs ou QDs qui sont capables, à la fois, de transporter un principe actif anticancéreux, i.e. la doxorubicine (DOX) et de le relarguer dans le milieu physiologique à une température contrôlée. Deux familles de NPs ont été synthétisées. La première concerne des NPs de Fe3O4 SPIO qui ont été modifiées en surface par un copolymère thermorépondant biocompatible à base de 2-(2-methoxy) méthacrylate d’éthyle (MEO2MA), oligo (éthylène glycol) méthacrylate (OEGMA). La seconde famille, consiste en des NPs de ZnO recouverte du même copolymère. Pour la première fois, le copolymère de type P(MEO2MAX-OEGMA100-X) a été polymérisé par activateur-régénéré par transfert d’électron-polymérisation radicalaire par transfert d’atome (ARGET-ATRP). La polymérisation et copolymérisation ont été initiées à partir de la surface. Les NPs cœur/coquilles ont été caractérisées par microscopie électronique à transmission (TEM), analyse thermogravimétrique (TGA), etc. Nous avons montré que l’efficacité du procédé ARGET-ATRP pour modifier les surfaces des NPs de SiO2, Fe3O4 et de ZnO. L’influence de la configuration de la chaîne de copolymère et des propriétés interfaciales avec le solvant ou le milieu biologique en fonction de la température a été étudiée. Nous avons montré que les propriétés magnétiques des systèmes coeur/coquilles à base de Fe3O4 ne sont influencées que par la quantité de polymère greffée contrairement au QDs qui vient leur propriété optique réduire au-delà de la température de transition. Ce procédé simple et rapide que nous avons développé est efficace pour le greffage de nombreux copolymères à partir de surfaces de chimie différentes. Les expériences de largage et relarguage d’un molécule modèle telle que la DOX ont montré que ces nanosystèmes sont capables de relarguer la DOX à une température bien contrôlée, à la fois dans l’eau que dans des milieux complexes tels que les milieux biologique. De plus, les tests de cytocompatibilité ont montré que les NPs coeur/coquilles ne sont pas cytotoxiques en fonction de leur concentration dans le milieu biologique. A partir de nos résultats, il apparaît que ces nouveaux nanomatériaux pourront être envisagés comme une plateforme prometteuse pour le traitement du cancer / One of the major challenges in nanomedicine is to develop nanoparticulate systems able to serve as efficient diagnostic and/or therapeutic tools against sever diseases, such as infectious or neurodegenerative disorders. To enhance the detection and interpretation contrast agents were developed to increase the signal/noise ratio. Among them, Superparamagnetic Iron Oxide (SPIO) and Quantum Dots (QDs) nanoparticles (NPs) have received a great attention since their development as a liver contrasting agent 20 years ago for the SPIO. Furthermore, their properties, originating from the nanosized dimension and shape, allow different bio-distribution and opportunities beyond the conventional chemical imaging agents. The opportunity to coat those biocompatible NPs by a polymer shell that can ensure a better stability of the materials in the body, enhance their bio-distribution and give them new functionalities. It has appeared then that they are very challenging for medicinal applications. In this work, we have developed new responsive SPIO and QDs based NPs that are able to carry the anticancer drug doxorubicin (DOX) and release it in physiological media and at the physiological temperature. Two families of NPs were synthesized, the first one consist in superparamagnetic Fe3O4 NPs that were functionalized by a biocompatible responsive copolymer based on 2-(2-methoxy) ethyl methacrylate (MEO2MA), oligo (ethylene glycol) methacrylate (OEGMA). The second family consists in the ZnO NPs coated by the same copolymer. For the first time, P(MEO2MAX-OEGMA100-X) was grown by activator regenerated by electron transfer–atom radical polymerization (ARGET-ATRP) from the NPs surfaces by surface-initiated polymerization. The core/shell NPs were fully characterized by the combination of transmission electron microscopy (TEM), thermogravimetric analysis (TGA), and by the physical properties of the nanostructures studied. We demonstrate the efficiency of the ARGET-ATRP process to graft polymers and copolymers at the surface of Fe3O4 and ZnO NPs. The influence of the polymer chain configuration (which leads to the aggregation of the NPs above the collapse temperature of the copolymer (LCST)) was studied. We have demonstrated that the magnetic properties of the core/shell Fe3O4-based nanostructures were only influenced by the amount of the grafted polymer and no influence of the aggregation was evidenced. This simple and fast developed process is efficient for the grafting of various co-polymers from any surfaces and the derived nanostructured materials display the combination of the physical properties of the core and the macromolecular behavior of the shell. The drug release experiments confirmed that DOX was largely released above the co-polymer LCST. Moreover, the cytocompatibility test showed that those developed NPs do not display any cytotoxicity depending on their concentration in physiological media. From the results obtained, it can be concluded that the new nanomaterials developed can be considered for further use as multi-modal cancer therapy tools
4

Microfluidic-assisted synthesis and release properties of multi-domain polymer microparticles drug carriers / Synthèse de vecteurs microparticulaires par microfluidique et études de la libération à partir de microparticules polymères multi-domaines

Khan, Ikram Ullah 24 October 2014 (has links)
Les caractéristiques et les propriétés de libération de microparticules chargées de médicament dépendent de la nature des matériaux employés, des propriétés physicochimiques des microparticules, du choix de la méthode de production, et enfin des propriétés des molécules encapsulées. A l'inverse de la plupart des méthodes conventionnelles, les méthodes microfluidiques présentent l’avantage de bien mieux contrôler la génération de gouttelettes, leur taille et leur distribution de tailles. Ainsi des dispositifs microfluidiques à base de capillaires ont été développés pour obtenir des microbilles de polymère mais également des microparticules de type janus, coeur-écorce ou troyenne, toutes monodisperses en taille et chargées de médicament(s). Ces particules ont été produites à partir de solutions de monomère qui furent polymérisées par irradiations UV de telle sorte à garder intacte l'activité des molécules chargées. Ces dispositifs peuvent être assemblés dans un court laps de temps et un simple changement dans leur conception permet d’obtenir des morphologies de particules très différentes. Ces particules ont été développées dans le but de résoudre les problèmes rencontrés dans l’administration orale de médicaments. Par exemple les microbilles peuvent être utilisées pour délivrer des anti-inflammatoires non stéroïdiens de manière continue tandis que les particules Janus peuvent libérer, simultanément et sur le même site, deux principes actifs possédant des propriétés complètement différentes (solubilité, compatibilité) également de manière prolongée. Quant aux particules coeur-écorce, elles ont été conçues pour cibler la région du côlon de l'intestin humain, et y libérer simultanément deux médicaments. Les particules troyennes furent synthétisées à l’aide d’un procédé microfluidique semi-continu qui a permis une manipulation plus sécurisée des nanoparticules vectrices ainsi que la libération continue d’un médicament dans un liquide gastrique simulé. Chaque système a été entièrement caractérisé pour assurer l’invariance entre lots et la reproductibilité. En général, la libération des ingrédients actifs a pu être facilement contrôlée/ajustée par le réglage des paramètres opératoires et de matériaux tels que les débits des différentes phases, la nature et la concentration du médicament, des (co)monomères, des agents tensioactif et de réticulation, le pH du milieu de libération. Ces différents paramètres influencent les propriétés des microparticules telles que leur morphologie, forme, taille et densité de réticulation du réseau polymère. / Characteristics and release properties of drug loaded microparticles depend upon material used and choice of production method. Conversely to most of the conventional ones, microfluidic methods give an edge by improving the control over droplet generation, size and size distribution. Capillary-based microfluidic devices were successfully used to obtain monodisperse drug(s) loaded microbeads, janus, core-shell and trojan particles using UV initiated free radical polymerization while keeping activity of active loaded molecules. These devices can be assembled in a short period of time and a slight change in design gives completely different microparticles morphologies. These particles were developed with the aim to address different issues experienced in oral drug delivery. For instance microbeads can be used to deliver NASIDs in a sustained release manner while janus particles can release two APIs with completely different properties (solubility, compatibility) also in a sustained release manner. Core-shell particles were designed to target colonic region of human intestine for dual drug delivery. Trojan particles were synthesized in a new semi-continuous microfluidic process, thus improving nanoparticles safety handling and release in simulated gastric fluid. Each system was fully characterized to insure batch to batch consistency and reproducibility. In general, the release of active ingredients was controlled by tuning the operating and material parameters like phases flow rates, nature and concentration of drug, (co)monomers, surfactant and crosslinker, pH of release media with the result of different particle morphologies, sizes and shapes or matrix crosslinking density.
5

Interactions et propriétés physico-chimiques de surfaces modèles de biomatériaux

Giraud, Lucie 12 1900 (has links)
La surface d’un implant ou d’un système à libération contrôlée de médicament est la première zone en contact avec les systèmes physiologiques. Les propriétés de surface vont alors définir le devenir à court et long termes de ces biomatériaux dans l’organisme. Pour améliorer la biointégration mais aussi l’efficacité des matériaux en contact avec les fluides et tissus biologiques, un fin contrôle des phénomènes se produisant à l’interface biologique est nécessaire. Cette thèse s’intéresse à l’étude de trois types de surfaces pouvant modéliser celles de biomatériaux couramment employés. Dans un premier temps, la stabilité hydrolytique de surface amino-fonctionnalisée a été investiguée. L’amino-fonctionnalisation de surface via l’emploi de monocouche auto-assemblée rencontre un intérêt certain pour l’ancrage de diverses molécules, macromolécules, systèmes colloïdaux et cellules. Cependant, le manque de stabilité en milieu aqueux limite grandement leurs perspectives d’utilisation pour la fonctionnalisation de surface de biomatériaux. Dans ce manuscrit, une monocouche amino-fonctionnalisée à base d’aminoalkylsilane a été greffée sur des substrats de silicate (silice et mica). L’extrême stabilité hydrolytique rapportée pour cette monocouche permet une immersion prolongée en milieu aqueux et sur une large gamme de pH. Les paramètres ayant été identifiés comme impactant cette stabilité sont l’organisation de la monocouche, la densité de greffage et la longueur de la chaîne carbonée de l’aminoalkylsilane. Dans un second temps, les propriétés lubrifiantes en milieu aqueux de surfaces structurées sont rapportées. Le besoin en surface autolubrifiante couvre une large variété de biomatériaux tels que les substituts cartilagineux, les dispositifs oculaires ou bien les cathéters. Des structures dômes ont été produites sur des surfaces via l’immobilisation de particules. Des particules polymériques à base de polyélectrolytes sensibles aux variations de pH ont permis l’obtention de structures molles et déformables alors que l’immobilisation de particules de silice a permis la formation de structures dures. Deux mécanismes majeurs contrôlant les propriétés de frottement ont été mis en évidence. Les surfaces structurées à partir de polyélectrolytes présentent des propriétés de frottement directement corrélées au gonflement et donc à la teneur en eau de ces structures. Ce ii gonflement peut être contrôlé par le pH du milieu aqueux. Plus les structures sont gonflées, plus le coefficient de frottement est faible. En revanche, avec des structures dures obtenues par l’immobilisation de particules de silice, le roulement de ces particules permet d’obtenir sous certaines conditions des coefficients de frottement extrêmement faibles. Dans ce cas, la nature du lien entre la particule et le substrat importe peu et un dégreffage systématique de certaines particules est observé pour permettre le mouvement des surfaces tout en limitant les forces de frottement. Dans un troisième temps, la complexation de simples brins de siARN via différentes natures d’interactions a été étudiée à l’aide de surfaces modèles de chimie variable. Cette étude a permis de démontrer la possibilité d'adsorber des simples brins de siARN via des interactions non-électrostatiques sur des surfaces planes. Des interactions hydrophobes et les liaisons hydrogène ont par la suite pu être employées pour complexer cet acide nucléique avec des formulations micellaires et liposomales non-cationiques. Cette étude permet d'envisager la conception de nanovecteurs non-cationiques et donc moins toxiques pour la délivrance de simples brins de siARN. Les travaux présentés dans ce manuscrit contribuent à l’élargissement des connaissances en matière de propriétés physico-chimiques de surface aux interfaces biologiques. / The surface of an implant or a drug delivery system is the first area of contact with biological environment. The surface properties of these biomaterials will define the short and long term behavior in the organism. To improve biointegration and efficiency, a fine control of the biological interface is required. This thesis investigates three different kind of surfaces modelling commonly used biomaterials. First, the hydrolytic stability of amino-functionalized surfaces was investigated. The amino-functionalization using self-assembled monolayers is required for the anchorage of molecules, macromolecules, colloidal systems and cells onto biomaterials. However, the lack of stability in aqueous media limits their use. In this manuscript, an amino-functionalized self-assembled monolayer made of aminoalkylsilane was grafted onto silicate substrates (silica and mica). The extreme robustness that we reported for this monolayer allows immersion into aqueous media for a wide range of pH and over long periods of time. The most important parameters that were identified that significantly impact the hydrolytic stability are the order of the monolayers, the grafting density and the length of the alkyl chain of the aminoalkylsilane. Second, the lubricant properties in aqueous media of structured surfaces are reported. The need in self-lubricant surfaces is required in a wide variety of biomaterials such as the cartilage substitute, ocular medical device or catheters. Domed structures were produced on surfaces through immobilization of particles. Polymeric nanoparticles composed of pH-sensitive polyelectrolytes were used to prepared soft and deformable structures while the immobilization of silica particles allows hard structures to be created. Two main mechanisms controlling friction properties were identified. Friction properties of structured surfaces made of polyelectrolytes were controlled by the swelling and the water content of the particles. This swelling can be tuned by changing the pH of the aqueous media. An increase in particle swelling leads to a decrease in the friction coefficient. However, with the hard structures, the rolling of the particles in some cases can also lead to extremely low friction coefficient. In that case, the nature of the attachment of iv the particle to the surface does not matter and systematic degrafting of some particles was observed which allows surfaces to slide with small friction forces. Third, the complexation of a single-stranded siRNA through different interactions was investigated with model surfaces of various chemistry. The results show that ss-siRNA can adsorb onto hydrophilic (positively and negatively charged) as well as on hydrophobic substrates suggesting that the complexation can occur through hydrophobic interactions and hydrogen bonding in addition to electrostatic interactions. This study suggests that non-electrostatic interactions could be exploited to complement electrostatic interactions in the design of less toxic nanocarriers and that non-cationics nanovectors can be employed as a potential single-stranded siRNA delivery systems. The results presented in this thesis contribute to increase the knowledge in the field of physico-chemistry surface properties of biological interfaces.

Page generated in 0.1371 seconds