• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 3
  • 2
  • Tagged with
  • 16
  • 10
  • 10
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analysis, modelling and linearization of nonlinearity and memory effects in power amplifiers used for microwave and mobile communications

Ahmed, Abdulrhman Mohammed Salman. January 2005 (has links)
University, Diss., 2005--Kassel. / Download lizenzpflichtig.
2

Nichtlineare zeitdiskrete Bahnplanung und Regelung unteraktuierter Manipulatoren /

Weidemann, Dirk. January 2006 (has links)
Zugl.: Hannover, Universiẗat, Diss., 2005. / Zsfassung in engl. Sprache.
3

Experimentelle Identifikation und nichtlineare Regelung eines einachsigen servohydraulischen Antriebs

Gücker, Jan Ulrich January 2005 (has links)
Zugl.: Kassel, Univ., Diss., 2005
4

Experimentelle Identifikation und nichtlineare Regelung eines einachsigen servohydraulischen Antriebs

Gücker, Jan Ulrich January 2005 (has links)
Zugl.: Kassel, Univ., Diss., 2005 / Download lizenzpflichtig
5

Experimentelle Identifikation und nichtlineare Regelung eines einachsigen servohydraulischen Antriebs

Gücker, Jan Ulrich. January 2006 (has links)
Universiẗat, Diss., 2005--Kassel. / Download lizenzpflichtig.
6

A mixed integer approach for the transient case of gas network optimization

Moritz, Susanne. Unknown Date (has links)
Techn. University, Diss., 2006--Darmstadt.
7

Konjugation stochastischer und zufälliger stationärer Differentialgleichungen und eine Version des lokalen Satzes von Hartman-Grobman für stochastische Differentialgleichungen

Lederer, Christian 10 October 2001 (has links)
Für zufällige dynamische Systeme mit stetiger Zeit existieren zwei wichtige Klassen von Generatoren: Zum einen stationäre zufällige ifferentialgleichungen, i.e. gewöhnliche Differentialgleichungen, die von einem stationärer zufälligen Vektorfeld getrieben werden, und zum anderen stochastische Stratonovichdifferentialgleichungen mit weißem Rauschen. Während die erste Klasse sich gut in den ergodentheoretischen Rahmen der Theorie der zufälligen dynamischen Systeme einfügt, widersetzte sich die zweite Klasse lange Zeit der dynamischen Untersuchung aufgrund des "Konflikts zwischen Ergodentheorie und stochastischer Analysis". In dieser Arbeit wird gezeigt, daß beide Klassen von zufälligen dynamischen Systemen nicht wesentlich verschieden sind, genauer: Zu jeder stochastischen Stratonovichdifferentialgleichung mit weißem Rauschen (unter den üblichen Regularitätsforderungen an die Vektorfelder, die die Existenz von Flüssen garantieren) existiert eine stationäre zufällige Differentialgleichung derart, daß die erzeugten zufälligen dynamischen Systeme konjugiert sind. Als Anwendung wird eine Version des lokalen Linearisierungssatzes von Hartman/Grobman für stochastische Stratonovichdifferentialgleichungen bewiesen. / For continuous time random dynamical systems there exist two important classes of generators: on the one hand stationary random differential quations, i.e. ordinary differential equations driven by a stationary random vector field, and on the other hand stochastic Stratonovich differential equations with white noise. While the first class fits well into the framework of the theory of random dynamical systems, the second class resisted for a long time the dynamical investigation due to the "conflict between ergodic theory and stochastic analysis". The main result of this thesis is that both classes of random dynamical systems are not essentially distinct, more precisely: For each stochastic Stratonovich differential equation with white noise (under usual regularity assumptions) there exists a stationary random differential equation such that the corresponding random dynamical systems are conjugate. As an application a version of the local Hartman/Grobman theorem for stochastic differential equations is proved.
8

Hyperbolicity & Invariant Manifolds for Finite-Time Processes

Karrasch, Daniel 19 October 2012 (has links) (PDF)
The aim of this thesis is to introduce a general framework for what is informally referred to as finite-time dynamics. Within this framework, we study hyperbolicity of reference trajectories, existence of invariant manifolds as well as normal hyperbolicity of invariant manifolds called Lagrangian Coherent Structures. We focus on a simple derivation of analytical results. At the same time, our approach together with the analytical results has strong impact on the numerical implementation by providing calculable expressions for known functions and continuity results that ensure robust computation. The main results of the thesis are robustness of finite-time hyperbolicity in a very general setting, finite-time analogues to classical linearization theorems, an approach to the computation of so-called growth rates and the generalization of the variational approach to Lagrangian Coherent Structures.
9

Hyperbolicity & Invariant Manifolds for Finite-Time Processes

Karrasch, Daniel 27 September 2012 (has links)
The aim of this thesis is to introduce a general framework for what is informally referred to as finite-time dynamics. Within this framework, we study hyperbolicity of reference trajectories, existence of invariant manifolds as well as normal hyperbolicity of invariant manifolds called Lagrangian Coherent Structures. We focus on a simple derivation of analytical results. At the same time, our approach together with the analytical results has strong impact on the numerical implementation by providing calculable expressions for known functions and continuity results that ensure robust computation. The main results of the thesis are robustness of finite-time hyperbolicity in a very general setting, finite-time analogues to classical linearization theorems, an approach to the computation of so-called growth rates and the generalization of the variational approach to Lagrangian Coherent Structures.
10

Vereinfachte Methoden zur optimalen Regelung resonanter Leistungskonverter / Simplify method for optimal control resonant power converter

Nittayarumphong, Sadachai 13 January 2009 (has links) (PDF)
Nowadays the developments of power supplies in military, industrial or commercial applications are growing rapidly, not only to achieve the highest efficiency but also to focus on the size and weight minimization which are playing a major role in this area. Therefore, the research trends in dc-dc, ac-dc, dc-ac, ac-ac topologies are still continuously developing into the direction of new topologies, new control concepts, new materials and devices to achieve highest efficiency and smallest size. The cost per unit is also one of the most important points of power supplies. Also, with new control methods and new ways of manufacturing, for example, the cost per unit might be reduced. Also, a simplified control concept might help to avoid discrete circuits, especially, at low power levels. The last mentioned statement is demonstrated, for instance, by the concept of the Link-Switch of the company Power Integration where an extremely small number of components are necessary. With the target of minimization, this research work explores the possibility to replace conventional electromagnetic transformers considered as the most bulky devices in power supplies by piezoelectric transformers (PT) for innovative off-line power supplies. Several control methods for a load resonant converter focusing on class-E topology utilizing PT, were developed in order to investigate and to select an appropriate control method capable of improving the efficiency and reducing the size of the converter. Efficiency should be understood in this way as maximum reliability at minimum power losses. Different controllers were evaluated for optimizing the effect of disturbances of line and load variations. The ZVS condition for a wide input voltage range and a wide output load range can be achieved by a method called duty-cycle tracking. Further, with an improved design of the PT containing an auxiliary tap, the ZVS condition can be obtained by a method called turn-on synchronization. The controlled output voltage, current or power is achieved by a variable frequency control. Further, the dynamic modeling for open loop and closed loop of load resonant converters, focused on the class-E topology, was introduced. The transient behavior of the output voltage of the open loop against perturbations such as the input voltage change, the switching frequency change, and the output load change is treated by replacing the complete circuit of the class-E converter by simple equivalent circuit models. The results from the analysis of the open loop dynamic behavior are applied to modeling the closed loop class-E converter with several control methods. The methods of linearization for exact solution and heuristic approximation for the steady state analysis were purposed. These models of linearization were implemented with the controller in its topologies to investigate the sufficient accuracy of obtained results of the regulation. Besides, the linearization models were used to observe the stability condition of the proposed control loops. Finally, the evaluation of a well-known classical control such P, I, PI, PD, PID and a simplified controller for a fixed load application by matching an appropriate switching frequency according to the input voltage, into the load resonant converter, considering class-E topology, were presented. Also, the optimum design of the controller for a load resonant converter was discussed and derived. / Die Entwicklung von Stromversorgungen in militärischen, industriellen und kommerziellen Anwendungen nimmt bis heute tendenziell stark zu. Nicht nur zur Erzielung höchster Wirkungsgrade, sondern auch im Hinblick auf Baugrößen- und Gewichtsminimierung, welche eine vorrangige Rolle spielen, ist diese Tendenz zu verzeichnen. Diesbezüglich gehen die Forschungstrends bei DC-DC, AC-DC, DC-AC und AC-AC Topologien in Richtung neuer Topologien, neuer Regelungskonzepte, sowie neuer Materialien und Bauelemente, um den höchsten Wirkungsgrad bei kleinster Baugröße zu erreichen. Die Gerätekosten sind ebenso ein sehr wichtiger Punkt bei Stromversorgungen. Auch durch neue Regelungsmethoden und durch neue Herstellungsverfahren können die Gerätekosten beispielsweise reduziert werden. Ebenso kann ein vereinfachtes Regelungskonzept dazu verhelfen, dass diskrete Schaltungen, speziell im unteren Leistungsbereich, vermieden werden. Letzteres wird beispielsweise beim Konzept des Link-Switch der Firma Power Integration verdeutlicht, indem extern wenige Bauelemente benötigt werden. Mit dem Ziel der Miniaturisierung wird in dieser Forschungsarbeit die Möglichkeit untersucht, konventionelle elektromagnetische Transformatoren, welche in Stromversorgungen als besonders voluminös gelten, durch piezoelektrische Transformatoren (PT) bei der Herstellung innovativer Netzstromversorgungen zu ersetzen. Verschiedene Regelungsmethoden für Lastresonanzkonverter, mit dem Fokus auf eine Klasse- E-Topologie mit PT, wurden hierzu entwickelt. Dies hatte zum Ziel, ein geeignetes Regelungsverfahren zu erarbeiten und auszuwählen, welches eine verbesserte Effizienz bei reduzierter Konverter-Baugröße aufzuweisen hat. Effizienz soll hierbei verstanden werden als maximale Zuverlässigkeit bei minimalen Leistungsverlusten. Verschiedene Reglertypen wurden entworfen um die Effekte der Störungen durch Netzspannungs-und Lastvariationen regelungstechnisch zu optimieren. Die Nullspannungsschaltungsbedingung (ZVS-Bedingung) über einen weiten Bereich der Eingangspannung und einen weiten Lastbereich kann durch einen sogenannte Duty-Cycle-Nachführung mit der Frequenz erreicht werden. Weiterhin kann durch eine verbesserte Ausführung des PT auf Basis einer Hilfsanzapfung die ZVSBedingung durch eine sogenannte Einschaltsynchronisation erreicht werden. Geregelte Ausgangsspannung, Ausgangsstrom oder Ausgangsleistung werden über eine Frequenzstellung erreicht. Die dynamische Modellierung der offenen und geschlossenen Regelschleife eines Lastresonanzkonverters, wieder im Hinblick auf die Klasse-E, wird im weiteren vorgestellt. Das transiente Verhalten der Ausgangsspannung der offenen Regelschleife gegenüber Störungen durch Eingangsspannungsänderung, durch Schaltfrequenzänderung oder durch Ausgangslaständerung, wird durch den Ersatz der Klasse-E-Schaltung durch einfache Äquivalenzmodelle behandelt. Die Ergebnisse der Analyse des Verhaltens des offenenen Regelkreises werden verwendet, um den Klasse-E-Konverter mit geschlossener Regelschleife unter Verwendung verschiedener vorgestellter Regelungsmethoden zu modellieren. Methoden der Linearisierung für die exakte Lösung und für eine heuristische Approximation der statischen Analyse des eingeschwungenen Zustands werden vorgeschlagen. Diese Methoden der Linearisierung werden zusammen mit den Reglermodellen in deren jeweilige Topologie implementiert um die ausreichende Genauigkeit der erhaltenen Resultate des Regelungsverhaltens zu beurteilen. Weiterhin werden diese Linearisierungsmodelle dazu verwendet, die Stabilitätskriterien der vorgeschlagenen Regelschleife zu überwachen. Schlussendlich wird die Bestimmung der bekannten klassischen Regler (P, I, PI, PD, PID), sowie eines vereinfachten Konstantlaststellers durch geeignete Anpassung der Schaltfrequenz an die Eingangsspannung, für Lastresonanzkonverter, wieder mit Blick auf die Klasse-E, vorgestellt. Außerdem wird der optimierte Reglerentwurf für Lastresonanzkonverter diskutiert und abgeleitet.

Page generated in 0.0825 seconds